Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM PROFILES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

SU-E-J-91: Novel Epitaxial Silicon Array for Quality Assurance in Photon and Proton Therapy

Purpose: to demonstrate suitability of a novel silicon array for measuring the dose properties of highly conformal photon and proton beams. Methods: prototype under test is a 24cm long linear array prototype, although the underlying technology is suitable to construct 2D arrays as well. It is based on a 64pixels monolithic sensor with 1mm pixel pitch, made of epitaxial ptype silicon. Thanks to design modularity, more sensors can be placed side by side without breaking pixel pitch. Flattened and unflattened photon beams, as well as proton radiation from a cyclotron in pencil beam scanning mode, were considered. Measurements of beam characteristics as percentage depth doses, dose profiles, output factors and energy response, which are necessary to deliver radiation with high precision and reliability, were performed. Results: Dose rate independence with photons was verified in the dose per pulse range 0.03 to 2mGy. Results clearly indicate nondependence of the detector sensitivity both for flattened and unflattened beams, with a variation of at most 0.5percentage. OFs were obtained for field with a lateral size ranging from 0.8cm to 16cm and the results are in good agreement with ion chamber A1SL, max difference less than 1.5percentage. Field sizes and beam penumbra were measured and compared to EBT film results. Concerning proton beams, sensitivity independence on dose rate was verified by changing the beam current in the interval 2-130Gy/s. Field sizes and beam penumbra measurements are in agreement with data taken with a scintillating 2D array with 0.5mm resolution IBA Lynx, and a better penumbra definition than an array of ionization chambers IBA MatriXX is reached. Conclusion: The device is a novel and valuable tool for QA both for photon and proton dose delivery. All measurements demonstrated its capability to measure with high spatial resolution many crucial properties of the RT beam.

07 ISOTOPE AND RADIATION SOURCES↗

Steady state scenario development with elevated minimum safety factor on DIII-D

On DIII-D, a high β scenario with minimum safety factor (q min ) near 1.4 has been optimized with new tools and shown to be a favourable candidate for long pulse or steady state operation in future devices. Furthermore, the new capability to redirect up to 5 MW of neutral beam injection (NBI) from on- to off-axis improves the ability to sustain elevated q min with a less peaked pressure profile. The observed changes increase the ideal magnetohydrodynamics (MHD) n = 1 mode β N limit thus providing a path forward for increasing the noninductive current drive fraction by operating at high β N . Quasi-stationary discharges free of tearing modes have been sustained at βN = 3.5 and β T = 3.6% for two current profile diffusion timescales (about 3 s) limited by neutral beam duration. The discharge performance has normalized fusion performance expected to give fusion gain Q ≈ 5 in a device the size of ITER. Analysis of the poloidal flux evolution and current drive balance show that the loop voltage profile is almost relaxed even with 25% of the current driven inductively, and q min remains elevated near 1.4. Our observations increase confidence that the current profile will not evolve to one unstable to a tearing mode. In preliminary tests a divertor heat flux reduction technique based on producing a radiating mantle with neon injection appears compatible with this operating scenario. 0D model extrapolations suggest it may be possible to push this scenario up to 100% noninductive current drive by raising β N . Similar discharges with q min = 1.5–2 were susceptible to tearing modes and off-axis fishbones, and with q min > 2 lower normalized global energy confinement time is observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-D-213-02: Characterization of the Effect of a New Commercial Transmission Detector On Radiotherapy Beams

Purpose: To evaluate the influence of a new commercial transmission detector on radiotherapy beams of various energies. Methods: A transmission detector designed for online treatment monitoring was characterized on a TrueBeam STx linear accelerator with 6MV, 6FFF, 10MV, and 10FFF beams. Measurements of beam characteristics including percentage depth doses (PDDs), inplane and crossplane off-axis profiles at different depths, transmission factors, and skin dose were acquired at field sizes of 3×3cm, 5×5m, 10×10cm, and 20×20cm at 100cm and 80cm source-to-surface distance (SSD). All measurements were taken with and without the transmission detector in the path of the beam. A CC04 chamber was used for all profile and transmission factor measurements. Skin dose was assessed at 100cm, 90cm, and 80cm SSD and using a variety of detectors (Roos and Markus parallel-plate chambers, and OSLD). Results: The PDDs showed small differences between the unperturbed and perturbed beams for both 100cm and 80cm SSD (≤4mm dmax difference and <1.2% average profile difference). The differences were larger for the flattened beams and at larger field sizes. The off-axis profiles showed similar trends. The penumbras looked similar with and without the transmission detector. Comparisons in the central 80% of the profile showed a maximum average (maximum) profile difference between all field sizes of 0.756% (1.535%) and 0.739% (3.682%) for 100cm and 80cm SSD, respectively. The average measured skin dose at 100cm (80cm) SSD for 10×10cm field size was <4% (<35%) dose increase for all energies. For 20×20cm field size, this value increased to <10% (≤45%). Conclusion: The transmission detector has minimal effect on the clinically relevant radiotherapy beams for IMRT and VMAT (field sizes 10×10cm and less). For larger field sizes, some perturbations are observable which would need to be assessed for clinical impact. The authors of this publication has research support from IBA Dosimetry.

60 APPLIED LIFE SCIENCES↗

Virtual Tokamak for Test and Development of Plasma Control Applied to NSTX-U

Safe and efficient operation of tokamak experiments depends on shot preparation prior to the experiment to maximize performance and avoid issues that are predictable consequences of known physics. The General Atomics TokSys toolbox is used to test and develop the plasma control system (PCS) on numerous tokamaks around the world. Tokamaks that use a version of the DIII-D PCS can connect it to a TokSys simulation and control a virtual version of the tokamak with the real PCS. Recent upgrades to the simulation include more detailed profile and transport modeling to support design and implementation of optimized scenarios. The simulation combines a module called “Profiles” that simulates the 1D profiles of density, pressure, and current and a module called “GSevolve'' that evolves the 2D Grad-Shafranov equilibrium. The “Profiles'' module primarily uses simplified models for fueling, heating, and current. The TRANSP code provides precomputed diffusion coefficients and heating/current drive profiles from radio-frequency and neutral beam sources for the scenarios being simulated. The fidelity of a simulation can be enhanced by analyzing it with TRANSP and making corrections to the precomputed values and iterating until convergence. Simulations of the National Spherical Torus Upgrade (NSTX-U) are presented. It is shown that the simulation reproduces the experimental profile evolution. Here, the simulation has also been upgraded to reproduce the experimental outcome at points of bifurcation. This is demonstrated with a simulation of vertical displacement in NSTX-U.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-F-T-428: An Optimization-Based Commissioning Tool for Finite Size Pencil Beam Dose Calculations

Purpose: Finite size pencil beam (FSPB) algorithms are commonly used to pre-calculate the beamlet dose distribution for IMRT treatment planning. FSPB commissioning, which usually requires fine tuning of the FSPB kernel parameters, is crucial to the dose calculation accuracy and hence the plan quality. Yet due to the large number of beamlets, FSPB commissioning could be very tedious. This abstract reports an optimization-based FSPB commissioning tool we have developed in MatLab to facilitate the commissioning. Methods: A FSPB dose kernel generally contains two types of parameters: the profile parameters determining the dose kernel shape, and a 2D scaling factors accounting for the longitudinal and off-axis corrections. The former were fitted using the penumbra of a reference broad beam’s dose profile with Levenberg-Marquardt algorithm. Since the dose distribution of a broad beam is simply a linear superposition of the dose kernel of each beamlet calculated with the fitted profile parameters and scaled using the scaling factors, these factors could be determined by solving an optimization problem which minimizes the discrepancies between the calculated dose of broad beams and the reference dose. Results: We have commissioned a FSPB algorithm for three linac photon beams (6MV, 15MV and 6MVFFF). Dose of four field sizes (6*6cm2, 10*10cm2, 15*15cm2 and 20*20cm2) were calculated and compared with the reference dose exported from Eclipse TPS system. For depth dose curves, the differences are less than 1% of maximum dose after maximum dose depth for most cases. For lateral dose profiles, the differences are less than 2% of central dose at inner-beam regions. The differences of the output factors are within 1% for all the three beams. Conclusion: We have developed an optimization-based commissioning tool for FSPB algorithms to facilitate the commissioning, providing sufficient accuracy of beamlet dose calculation for IMRT optimization.

07 ISOTOPE AND RADIATION SOURCES↗

Focused ion beam high resolution grayscale lithography for silicon-based nanostructures

Nanofabrication techniques providing a fine control over the profile of silicon structures are of great importance for nanophotonics, plasmonics, sensing, micro- and nano fluidics, and biomedical applications. We report on the applicability of focused ion beam for the fine grayscale lithography, which yields surface profiles that are customized at nanoscale. The approach is based on a correlation between the ion beam irradiation dose of inorganic resist and the mask etching rate in the reactive ion etching. An exceptional property of this method is the number of gray tones that are not limited by the resist characteristics. We apply the process to fabricate unique periodic nanostructures with a slope angle varying across the structure and a period as small as 200 nm.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

ToF-SIMS Depth Profiling of Organic Delta Layers with Low-Energy Cesium Ions: Depth Resolution Assessment

The advent of cluster ion beams has paved the way to the routine 3D analysis of organic heterojunctions. Alternatively, organic thin layers have also been successfully depth profiled with a low-energy cesium ion beam (Cs{sup +}), to exploit the high chemical reactivity of cesium atoms, acting as free-radical scavengers. Despite of this, little is known about the depth resolution associated with low-energy Cs{sup +} sputtering on organic multilayers. In this work, amino acids multilayers, consisting of phenylalanine delta layers alternated with tyrosine spacers, were used as model systems to assess the depth resolution associated with 500 eV Cs{sup +} depth profiles. High yields were obtained for quasi-molecular ions from both amino acids, and no significant chemical alteration was noticed under the monoatomic bombardment. A depth resolution as low as 4 nm is demonstrated without sensible degradation on a rather long profile depth (300 nm). Limited depth resolution (> 10 nm) along with high molecular degradation was previously reported on similar systems by combining low-energy Cs{sup +} with Ga{sup +} analysis beam. The use of the Bi{sub 3}{sup +} analysis beam results in a dramatic improvement of both the characteristic molecular signal intensities and the depth resolution. Even though the analysis beam fluence is very low compared to the sputtering beam fluence, data suggest that further reducing the analysis Bi{sub 3}{sup +} fluence could improve the depth resolution by ~ 1 nm. .

74 ATOMIC AND MOLECULAR PHYSICS↗

Lunar Geodetic Opportunities with the Laser Altimeter on LRO

The Lunar Reconnaissance Orbiter (LRO) is to be launched at the end of 2008 and will carry 7 instruments, one of which is a laser altimeter (LOLA), and obtain observations of the Moon for a period of 1 year. The orbit will be near polar and approximately circular at 50 km altitude with monthly orbital adjustments to maintain the mean altitude. The LOLA instrument has a -10 cm single-shot accuracy, with 5 beams, and operates at 28 Hz. It provides 5 adjacent profiles, each approximately 12 to 15 meters apart with a swath of approximately 65 meters. The 5 beams are arranged in a cross-shaped pattern that provides simultaneous along and cross track altimetry and providing slopes in 2 orthogonal directions every 50 meters along track. In combination with the LRO tracking data LOLA will be used to improve the model of the lunar gravity by using the altimeter on both the lunar near-side and far-side as an additional tracking system to enable precise positioning of the LRO spacecraft at about the 50 meter level rms. The instrument is expected to provide full polar coverage at very high northern and southern latitudes with spatial resolutions of 25 meters or better. In addition to the range to the surface LOLA measures the surface roughness from the spreading of the laser pulse and also the reflectance of the surface at 1064 nm. These measurements in conjunction with the altimetry will assist in the selection of future landing sites for future robotic and human missions to the Moon.

Zuber, Maria T.↗

Use of double-layer ITO films in reflective contacts for blue and near-UV LEDs

The structural and optical properties of multilayer ITO/SiO{sub 2}/Ag composites are studied. In these composites, the ITO (indium-tin oxide) layer is produced by two different methods: electron-beam evaporation and a combined method including electron-beam evaporation and subsequent magnetron sputtering. It is shown that the reflectance of the composite based on the ITO film produced by electron-beam evaporation is substantially lower. This can be attributed to the strong absorption of light at both boundaries of the SiO{sub 2} layer, which results from the complex surface profile of ITO films deposited by electron-beam evaporation. Samples with a film deposited by the combined method have a reflectance of about 90% at normal light incidence, which, combined with their higher electrical conductivity, makes these samples advantageous for use as reflective contacts to the p-type region of AlInGaN light-emitting diodes of the flip-chip design.

36 MATERIALS SCIENCE↗

SU-E-T-246: Detector Selection for Small Field Measurements, a Comparative Study

Purpose: To compare commercially available detectors for small field dosimetry. Methods: PTW (Freiburg, Germany) diode E, PTW microDiamond, and SunNuclear (Melbourne, FL) Edge detector were used to measure output factors, PDD, and profiles on a Varian iX linear accelerator (Varian Medical Systems, Palo Alto, CA) using 6MV and 18MV photon beams. The water tank was set to 100cm SSD. Centering profiles at 5cm and 20cm depth confirmed an offset <0.1mm. High resolution PDD (0.1mm) aligned the collecting volume at water surface. For setup and linearity verification, PDD and profiles were matched to annual measurements, which were performed with an A1SL ion chamber.Scans were taken for 6X and 18X, for 10cmx10cm, 10cmx2cm, 10cmx1cm, and 10cmx0.5cm fields. Profiles were measured at Dmax (6X=1.5cm, 18X=3.5cm), 5cm, 10cm, and 20cm depths. All fields used 10cmx10cm jaws with the MLC defining the field in the X-direction. PDDs used 2mm step size and 0.2s discrete collecting time. Profiles used 1mm step size and a 0.4s discrete collecting time. Results: The PTW diode E and Edge detector exhibit centering stability, but all detectors require vertical shifts from Vendor defined vertical alignment. Output factor measurements reveal good agreement between detectors. The Edge detector demonstrates the sharpest penumbra and the closest consistent match to ion chamber measurements in the out of field regions for 6MV (3.2%). Each detector provides comparable curve quality for PDDs, with a maximum difference across detectors giving a standard deviation of 0.6% at 30cm depth, 18X, and 10cmx0.5cm. Profiles match closely across all detectors, depths, energies, and field sizes. The microDiamond detector produces the largest penumbra width, largest deviation from ion chamber dose in the tail region for 6MV, and exhibits centering instability. Conclusion: Based on our findings, the Edge detector was chosen for stereotactic measurements. The PTW diode E is an acceptable alternative.

60 APPLIED LIFE SCIENCES↗

Realistic modeling of the pulse profile of PSR J0737-3039A

The Double Pulsar, PSR J0737-3039A/B, is a unique system in which both neutron stars have been detected as radio pulsars. As shown in Ferdman et al., there is no evidence for pulse profile evolution of the A pulsar, and the geometry of the pulsar was fit well with a double-pole circular radio beam model. Assuming a more realistic polar cap model with a vacuum retarded dipole magnetosphere configuration including special relativistic effects, we create synthesized pulse profiles for A given the best-fit geometry from the simple circular beam model. By fitting synthesized pulse profiles to those observed from pulsar A, we constrain the geometry of the radio beam, namely the half-opening angle and the emission altitude, to be ∼30° and ∼10 neutron star radii, respectively. Combining the observational constraints of PSR J0737-3039A/B, we are able to construct the full three-dimensional orbital geometry of the Double Pulsar. The relative angle between the spin axes of the two pulsars (Δ{sub S}) is estimated to be ∼(138° ± 5°) at the current epoch and will likely remain constant until tidal interactions become important in ∼85 Myr, at merger.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of an accelerator-based neutron source to prototype Mo-99 production, part I: A liquid LBE windowless target

In this article, Molybdenum-99 (Mo-99)’s decay product, technetium-99 (Tc-99 m), is one of the most critical isotopes for medical diagnostics. To provide U.S. domestic supply of Mo-99 without using high-enriched uranium (HEU), a subcritical uranium target assembly (UTA) is irradiated by an accelerator-based neutron source to create Mo-99 through fission. This study discusses the development of the accelerator-based neutron source. The high-energy electrons from the accelerator irradiate a liquid lead-bismuth eutectic (LBE) target to produce neutrons. Part I of this work focuses on numerical and experimental analysis towards the development of a liquid LBE windowless target. Unlike the existing windowless targets in literature, the current design creates a vertical free surface for a beam to irradiate. First, a hydrodynamic analysis of the LBE windowless target is performed. Simplified analytical calculations are assisted by 2D computational fluid dynamics (CFD) simulations to design the target, with the focus on eliminating recirculation zones and avoiding cavitation. With the optimized geometry, the experimental study is performed to investigate the flow hydrodynamics using liquid LBE. The experiments (1) compare pressure drop in the system to correlation predictions; (2) visualize the free surface liquid LBE flow from the beam view; (3) validate the LBE flow profile using temperature sensitive paint from the side view; and (4) validate the liquid LBE film thickness using gamma densitometer measurements. Second, the power handling capability of the designed windowless target is investigated. The divider plate in the current design is susceptible to overheating due to the thin LBE film in front. As LBE erosion and corrosion is likely to occur at an LBE velocity of 2.0 m/s and temperature above 500 °C, a power limit of 10 kW of beam power was established to prevent this corrosion from occurring, which is calculated by a Nusselt number correlation. The divider plate surface temperature at 10 kW agrees well with the 3D CFD simulation results. Part I demonstrates the fundamental physics in liquid LBE windowless target design and associated testing. A companion paper, Part II will demonstrate how to couple this windowless target into the Mo-99 production system, including an accelerator system operating under an ultra-high vacuum and the UTA cooled by water at room temperature.

43 PARTICLE ACCELERATORS↗

Production of fine structures in type III solar radio bursts due to turbulent density profiles

Magnetic reconnection events in the corona release energetic electron beams along open field lines, and the beams generate radio emission at multiples of the electron plasma frequency f{sub p} to produce type III solar radio bursts. Type III bursts often exhibit irregularities in the form of flux modulations with frequency and/or local temporal advances and delays, and a type IIIb burst represents the extreme case where a type III burst is fragmented into a chain of narrowband features called striae. Remote and in situ spacecraft measurements have shown that density turbulence is ubiquitous in the corona and solar wind, and often exhibits a Kolmogorov power spectrum. In this work, we numerically investigate the effects of one-dimensional macroscopic density turbulence (along the beam direction) on the behavior of type III bursts, and find that this turbulence produces stria-like fine structures in the dynamic spectra of both f{sub p} and 2 f{sub p} radiation. Spectral and temporal fine structures in the predicted type III emission are produced by variations in the scattering path lengths and group speeds of radio emission, and in the locations and sizes of emitting volumes. Moderate turbulence levels yield flux enhancements with much broader half-power bandwidths in f{sub p} than 2 f{sub p} emission, possibly explaining the often observed type IIIb-III harmonic pairs as being where intensifications in 2 f{sub p} radiation are not resolved observationally. Larger turbulence levels producing trough-peak regions in the plasma density profile may lead to broader, resolvable intensifications in 2 f{sub p} radiation, which may account for the type IIIb-IIIb pairs that are sometimes observed.

79 ASTRONOMY AND ASTROPHYSICS↗

A study of target heating in low-energy ion-beam processing

A bonded thermocouple approach is employed to accurately determine semiconductor surface heating profiles as a function of energy, position, and gas species in a high-current low-energy ion beam etching system. The total beam current is kept at 200 mA and the extractor voltage at 300 V. It is found that the ionic species, the radial position in the ion beam, and the kinetic energy of the ions, all of which effect the ion current density, must be taken into account in recording the temperature rise of the bombarded surface. It is also noted that the occurrence of this temperature rise is dependent on the thermal contacts and heat sinking.

Ringel, S. A.↗

Inferred UV fluence focal-spot profiles from soft x-ray pinhole-camera measurements on OMEGA

A method was developed with laser-irradiated Au planar foils to characterize the focal spot of UV laser beams on target at full energy from soft x-ray emission. A pinhole camera with a back-thinned charge-coupled–device detector and filtration with thin Be and Al foil filters provides images of the x-ray emission at photon energies <2 keV. This method requires a careful measurement of the relation between the applied UV fluence and the x-ray signal, which can be described by a power-law dependence. The measured exponent γ ~ 2 provides a dynamic range of ~25 for the inferred UV fluence. UV fluence profiles of selected beams were measured for 100-ps and 1-ns laser pulses and were compared to directly measured profiles from an UV equivalent-target-plane diagnostic. The inferred spot size and super-Gaussian order from the x-ray technique agree within several percent with the values measured with the direct UV measurements.

47 OTHER INSTRUMENTATION↗

Statistical Measurement of Longitudinal Beam Halo in Fermilab Recycler

The formation of non-Gaussian halo in both the transverse and longitudinal dimensions of beam bunches has been notoriously difficult both the model and to measure. We present a technique to measure the longitudinal halo of 2.5 MHz bunches in the Fermilab Recycler, which have been formed for the g-2 anomalous magnetic moment experiment. While out of time beam is not a particular concern to this experiment, it is a key issue for the subsequent Mu2e rare muon decay experiment, which will use the same bunch formation procedure. Our measurement relies on a statistical technique, in which a small fraction of the beam is scattered from the primary collimation foil in the recycler, and then is detected by a charge telescope consisting of quartz Cherenkov radiators and photomultiplier tubes. By integrating over many revolutions, the time profile of longitudinal halo (out-of-time beam) can be measured down to less than a 10⁻⁵ fractional level, relative to in-time beam. These results can then be compared to simulations.

43 PARTICLE ACCELERATORS↗

Non-Rare Earth Magnesium Bumper Beams

Magna will team with the Pacific Northwest National Laboratory (PNNL) to develop Shear Assisted Processing and Extrusion (ShAPE™) of rectangular and multi-zoned extrusion profiles using non-RE Mg. It is envisioned that the ShAPE™ process, developed during this project for non-circular profiles, will serve as the foundation for fabrication of full-scale bumper beams of the future where near net-shapes are extruded directly from castings in a single step, without the need for costly rare earth additives. In this project, the ShAPE™ process will be developed for a rectangular profile measuring 1” x 2” with a 0.06” wall thickness. Successful extrusion of rectangular cross sections is a critical step along the path toward profiles with multiple zones. With the process established for a rectangular profile, the project will then make advancements toward multi-zoned cross sections. A magnesium alloy bumper beam offers a 35% weight savings compared to aluminum alloys and 60% compared to high strength steels. The bumper beam was chosen as the first component to target because the geometry can have a fairly simple 0.6-0.12 inch wall/web thickness, generally compatible with PNNL’s knowledge base and equipment capability surrounding ShAPE™. The bumper component offers commercial value by providing mass reduction in the front of the vehicle along with ride and handling benefit. PNNL has demonstrated the ability to ShAPE™ process non-RE Mg tubing with high strength, ductility and energy absorption. It has been shown that ShAPE™ extruded ZK60 and Mg2Si tubing with 0.30 inch diameter and 0.03 inch wall thickness have similar energy absorption to AA6061-T6. This is due to significant grain refinement, breakdown and dispersion of second phases, and the ability to eliminate anisotropy in compressive/tensile strength by aligning texture 45 degrees to the extrusion axis. Scalability of the ShAPE™ process has been demonstrated in ZK60 by fabricating 2.0 inch diameter tubing with 0.06 and 0.12 inch wall thicknesses having concentricity as tight as 1.3%. These tubes exhibit an ultimate tensile strength of 260-300 MPa and room temperature ductility of >20% parallel, perpendicular and 45 degrees to the extrusion axis. Aluminum bumpers represent approximately 54% of the NA light vehicle market. If the research effort is successful, providing a 30% mass reduction at equal cost relative to aluminum bumpers, it is anticipated that 25% market penetration would be realized over the next 5 year and 50% market share by 2030. 100% of the aluminum automotive bumpers are sourced from the tier network, providing resourcing opportunity based on equal performance, reduced mass and cost equivalent lower than aluminum bumpers. Due to the relatively low vehicle content, magnesium components are currently shredded and 100% recycled with aluminum content in the US, presenting a positive life cycle impact.

42 ENGINEERING↗