Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Analysis facilities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Benchmarking FFTF LOFWOS Test# 13 using SAM code: Baseline model development and uncertainty quantification

The development and deployment of advanced reactors, such as the sodium-cooled fast reactor (SFR), relies on sophisticated modeling tools to ensure the safety of the design under various transients. The predictive capability of these advanced modeling tools requires validation to garner trust in supporting the licensing of the advanced reactors. For this reason, the International Atomic Energy Agency (IAEA) initiated a coordinated research project (CRP) in 2018 for the analysis of the Fast Flux Test Facility (FFTF) Loss of Flow Without Scram (LOFWOS) Test #13.In this study, we present and discuss the benchmarking efforts of the modern system code SAM on the FFTF LOFWOS Test #13. Further, the SAM baseline model was developed according to the benchmark specification, which included a detailed core model with reactivity feedback. Generally, good agreement was observed between the baseline results and benchmark measurements; however, discrepancies persisted, particularly in predicted fuel assembly coolant outlet temperatures. Utilizing the baseline model, uncertainty quantification (UQ) and sensitivity analysis (SA) were conducted with the assistance of various statistical learning and machine learning methods, including kernel density estimation, Gaussian processes, and Sobol indices. Following the baseline model prediction and UQ and SA results, we discuss the reasons for the simulation discrepancies and propose further improvements to the model. This benchmarking effort adheres to the best-estimate plus uncertainty approach and can serve as a valuable example for supporting risk-informed licensing of advanced reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis of an optical imaging system prototype for autonomously monitoring zooplankton in an aquaculture facility

Traditional approaches to biomonitoring in aquatic systems, such as sample collection, sorting, and identification, require significant time and effort, thereby limiting the spatiotemporal resolution of sample collection. Additionally, collection and preservation of samples for subsequent taxonomic identification and enumeration leads to mortality of organisms. Recent advances in technologies that utilize optical imaging and machine learning have provided new opportunities to expedite biomonitoring and lead to significant cost savings. These technologies can be advantageous to scientists or managers that conduct routine biomonitoring to inform operations, as in the case of aquaculture facilities. The Small Aquatic Organism optical imaging system (SAO) is a high-throughput optical imaging and classification prototype system that relies on computer vision and machine learning (Support Vector Machines, or SVMs) to autonomously identify and enumerate aquatic organisms. The SAO provides a more sustainable method of collecting large volumes of data and has the benefit of being used in situ. In this study, we tested the performance of the SAO in providing comparable results to manual zooplankton community monitoring in ten ponds at an aquaculture facility. We performed a side-by-side study comparing the sampling methods of plankton tow nets, where major zooplankton taxonomic classes were manually identified and enumerated, to sampling with the SAO. Vouchered samples were used to develop a training library for the SAO, where classes consisted of water boatman and zooplankton groups: cladocerans, copepod adults, copepod nauplii, and rotifers. SAO imagery was manually classified and compared with predicted results for validation. Accuracy for the SVM classifier of the SAO was 37.4 %. Convolutional Neural Networks (CNN) and Random Forest classifiers were also applied to SAO imagery and image features for comparison. The best CNN model and our Random Forest model had accuracies of 80.4 % and 46.6 % respectively. Challenges faced included the small size of copepod nauplii and rotifers and the limited resolution of the imaging camera, although there are tradeoffs between imaging resolution and the sample processing rate. Furthermore, our comparison shows that advancement in both optical imaging and ML are needed in order for the SAO prototype to yield comparable results to manual community monitoring in an aquaculture facility.

54 ENVIRONMENTAL SCIENCES↗

SHIELDING ANALYSIS FOR X-RAY SOURCES GENERATED IN TARGET CHAMBER OF THE NATIONAL IGNITION FACILITY

Prompt doses from x-rays generated as result of laser beam interaction with target material are calculated at different locations inside the National Ignition Facility (NIF). The maximum dose outside a Target Chamber diagnostic port is {approx} 1 rem for a shot utilizing the 192 laser beams and 1.8 MJ of laser energy. The dose during a single bundle shot (8 laser beams) drops to {approx} 40 mrem. Doses calculated outside the Target Bay doors and inside the Switchyards (except for the 17 ft.-6 in. level) range from a fraction of mrem to about 11 mrem for 192 beams, and scales down proportionally with smaller number of beams. At the 17ft.-6 in. level, two diagnostic ports are directly facing two of the Target Bay doors and the maximum doses outside the doors are 51 and 15.5 mrem, respectively. Shielding each of the two Target Bay doors with 1/4 in. Pb reduces the dose by factor of fifty. One or two bundle shots (8 to 16 laser beams) present a small hazard to personnel in the Switchyards.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Beam-Dynamics Analysis of Long-Range Wakefield Effects on the SCRF Cavities at the Fast Facility

Long-range wakefields in superconducting RF (SCRF) cavities create complicated effects on beam dynamics in SCRF-based FEL beamlines. The driving bunch excites effectively an infinite number of structure modes (including HOMs) which oscillate within the SCRF cavity. Couplers with loads are used to damp the HOMs. However, these HOMs can persist for long periods of time in superconducting structures, which leads to long-range wakefields. Clear understanding of the long-range wakefield effects is a critical element for risk mitigation of future SCRF accelerators such as XFEL at DESY, LCLS-II XFEL, and MaRIE XFEL. We are currently developing numerical tools for simulating long-range wakefields in SCRF accelerators and plan to experimentally verify the tools by measuring these wakefields at the Fermilab Accelerator Science and Technology (FAST) facility. This paper previews the experimental conditions at the FAST 50 MeV beamline based on the simulation results.

43 PARTICLE ACCELERATORS↗

Advanced Post-Irradiation Examination Capabilities Alternatives Analysis Report

An alternatives analysis was performed for the Advanced Post-Irradiation Capabilities (APIEC) project in accordance with the U.S. Department of Energy (DOE) Order DOE O 413.3B, “Program and Project Management for the Acquisition of Capital Assets”. The Alternatives Analysis considered six major alternatives: 1. No Action, 2. Modify Existing DOE Facilities – capabilities distributed among multiple locations, 3. Modify Existing DOE Facilities – capabilities consolidated at a few locations, 4. Construct New Facility, 5. Commercial Partnership, and 6. International Partnerships. Based on the alternatives analysis documented herein, it is recommended to DOE that the advanced post-irradiation examination capabilities be provided by a new facility constructed at the Materials and Fuels Complex at the Idaho National Laboratory.

42 ENGINEERING↗

Analysis of Uranium Ion Exchange Resin from the 200 West Pump-and-Treat Facility

The 200 West Area Pump-and-Treat (P&T) Facility at the Hanford Site is a multifunctional groundwater treatment facility consisting of unit processes to remove radionuclides such as uranium (U) and technetium (Tc-99) as well as other inorganic (nitrate and hexavalent chromium), and organic (carbon tetrachloride and trichloroethene) contaminants. The RAD building of the P&T Facility removes U and Tc-99 using ion exchange chromatography. In 2016, the Purolite A530E resin used for the Tc-99 removal was replaced and the spent resin was analyzed. In addition to Tc-99, the Purolite A530E resin also retained I-129 and Co-60; however, the resin loading was dominated by common groundwater constituents such as calcium, iron, silicon, and sulfate.

54 ENVIRONMENTAL SCIENCES↗

Analysis of Technetium Ion Exchange Resin from the 200 West Pump-and-Treat Facility

The 200 West Area Pump-and-Treat (P&T) facility at the Hanford Site is a combined treatment train consisting of unit processes to remove radionuclides such as uranium (U) and technetium (Tc-99), other inorganic (nitrate and hexavalent chromium), and organic (carbon tetrachloride and trichloroethene) contaminants. The RAD building of the P&T facility removes Tc-99 and U using ion exchange chromatography, while the other inorganic and organic contaminants are removed in the facility’s BioPlant portion. The original design of the ion exchange resin for Tc-99 allowed for a 3-month Tc-99 breakthrough and subsequent resin canister change out. However, no Tc-99 breakthrough was noted for 3 years. The objective of the work was to analyze spent resin to determine if there are other compounds that may interfere with Tc-99 adsorption, and to determine whether the resin was removing any I-129.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fire-Induced Pressure Response and Failure Characterization of PCV/SCV/3013 Containers - Phase 3

Several Department of Energy (DOE) facilities have materials stored in robust, welded, stainless - steel containers with presumed fire - induced pressure response behaviors. Lack of test data related to fire exposure requires conservative safety analysis assumptions for container response at these facilities. This conservatism can in turn result in the implementation of challenging operational restrictions with costly nuclear safety controls. To help address this issue for sites that store DOE 3013 stainless - steel containers, a series of ten tests were undertaken at Sandia National Laboratories. The goal of this test series was to obtain the response behavior for various configurations of DOE 3013 containers with various payload compositions when exposed to one of two ASTM fire conditions. Key parameters measured in the test series included identification of failure - specific characteristics such as pressure, temperature, and whether or not a vessel was breached during a test . Numerous failure - specific characteristics were identified from the ten tests. This report describes the implementation and execution of the test series performed to identify these failure - specific characteristics. Discussions on the test configurations, payload compositions, thermal insults, and experimental setups are presented. Test results in terms of pressurization and vessel breach (or no - breach) are presented along with corresponding discussions for each test.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Digital Image Correlation Strain Field Analysis of Materials for Target Systems

Many accelerator facilities are currently being limited in beam power by their target facilities. When exposed to high-energy proton beams, target systems experience radiation damage, mechanical stress, and extreme temperatures, altering their physical properties.For example, due to defects induced in materials by high-energy protons, the physical properties of materials will change during irradiation. Conducting PIEs (Post Irradiation Examinations) can help us understand how the materials can change.Analyzing the strain field across an irradiated sample can help identify where defects have been created, how the hardness of materials have changed, and where they will experience failure.

Ayyildiz, Onat↗

System reliability analysis through corona testing

A corona vacuum test facility for nondestructive testing of power system components was built in the Reliability and Quality Engineering Test Laboratories at the NASA Lewis Research Center. The facility was developed to simulate operating temperature and vacuum while monitoring corona discharges with residual gases. The facility is being used to test various high-voltage power system components.

Lalli, V. R.↗

An analysis of maximum vertical gusts recorded at NASA's 150-meter ground winds tower facility at Kennedy Space Center, Florida

A statistical summary is presented of vertical wind speed data recorded at NASA's 150-Meter Ground Winds Tower Facility on Merritt Island, Kennedy Space Center, Florida. One year of continuous around-the-clock vertical wind speed measurements processed by the Automatic Data Acquisition System (ADAS) is classified as a function of tower level (10, 18, 60, and 150 meters) and period of reference day, month, season: winter (October through March) and summer (April through September), and annual. Intensity, frequency, time of occurrence, prevailing conditions, etc., of the daily maximum vertical gusts (i.e., updraft and downdraft) are determined. The results are compared with the vertical gusts associated with the daily maximum horizontal gust. The intent of this summarization of vertical wind speed data is to provide a general description of wind flow in the lower 150 meters of the atmosphere for the identification of hazards involved in wind shear encounters relative to ascent and descent of the Space Shuttle and conventional aircraft.

Alexander, M. B.↗

In-flight flow field analysis on the NASA F-18 high alpha research vehicle with comparisons to ground facility data

In-flight flow visualization results of the vortical flow on the forebody and leading-edge extensions (LEX) of an F-18 research aircraft have been presented for angles of attack from 15.8 to 42.5 deg and for sideslip angles up to 7.5 deg. Water tunnel results using a 3-percent scale F-18 model and a variety of wind tunnel results are used for comparison and interpretation of the flight results. The LEX vortex core breakdown point moved forward with increasing angle of attack. For a constant angle of attack, the windward LEX vortex core breakdown moves forward and inboard with sideslip and the leeward vortex core breakdown moves aft and outboard. For a constant angle of attack, the windward location of interaction moved aft with increasing sideslip and the leeward interaction moved forward.

Del Frate, John H.↗

Availability Estimation for Facilities in Extreme Geographical Locations

A value added analysis for the Reliability. Availability and Maintainability of McMurdo Ground Station was developed, which will be a useful tool for system managers in sparing, maintenance planning and determining vital performance metrics needed for readiness assessment of the upgrades to the McMurdo System. Output of this study can also be used as inputs and recommendations for the application of Reliability Centered Maintenance (RCM) for the system. ReliaSoft's BlockSim. a commercial Reliability Analysis software package, has been used to model the availability of the system upgrade to the National Aeronautics and Space Administration (NASA) Near Earth Network (NEN) Ground Station at McMurdo Station in the Antarctica. The logistics challenges due to the closure of access to McMurdo Station during the Antarctic winter was modeled using a weighted composite of four Weibull distributions. one of the possible choices for statistical distributions throughout the software program and usually used to account for failure rates of components supplied by different manufacturers. The inaccessibility of the antenna site on a hill outside McMurdo Station throughout one year due to severe weather was modeled with a Weibull distribution for the repair crew availability. The Weibull distribution is based on an analysis of the available weather data for the antenna site for 2007 in combination with the rules for travel restrictions due to severe weather imposed by the administrating agency, the National Science Foundation (NSF). The simulations resulted in an upper bound for the system availability and allowed for identification of components that would improve availability based on a higher on-site spare count than initially planned.

Fischer, Gerd M.↗

Microbes Share Rides Too: Updating Encapsulated Bioburden Estimate Values in Electronic Parts Common to Class D Mission Platforms.

As NASA develops more planetary protection missions that are Category III and in the Class D/rideshare mission platform, there is an increasing reliance on estimation of prelaunch bioburden to understand needs for burn up and breakup analyses or other methods to meet pre-launch bioburden levels. Current levels estimated for the encapsulated bioburden of semiconductor parts cited by NASA have been based on estimates of semiconductor manufacturing approaches from the 1970s that do not incorporate over fifty years of evolving cleanliness of semiconductor manufacturing processes and facilities. This investigation will focus on direct sampling of semiconductor parts for encapsulated bioburden values, drawing upon Goddard’s strength in EEE parts, supply chain management, destructive parts analysis and existing local planetary protection lab facilities to prepare and measure encapsulated bioburden at a statistically significant level for standard electronics parts common to known Class D/rideshare platforms.

planetary protection↗

Computational Analysis of a Boundary-Layer Ingesting Tailcone Thruster Configuration Within the National Transonic Facility Using the LAVA Solver

Boundary-layer ingesting (BLI) propulsion systems are one of the many technologies currently under investigation within the aerospace community to meet NASA’s Advanced Air Transport Technology project goal of a sustainable future in aviation. To that end, an experimental campaign was conducted in the National Transonic Facility (NTF) to study the propulsion-airframe integration effects of the Boundary-Layer Ingesting Tailcone System installed in the aft portion of a 2.7% scale design of the NASA Common Research Model (CRM). This test was accompanied by a numerical simulation effort using the Launch, Ascent, and Vehicle Aerodynamics (LAVA) solver, to validate the applicability of current best-practice Reynolds-averaged Navier Stokes (RANS) models in accurately predicting the relevant flow-physics in free-air. A total of 205 steady RANS simulations were performed using LAVA, covering the range of conditions present in the NTF test matrix. Flow conditions ranged from 5- to 15-million Reynolds number, Mach numbers of 0.75, 0.80 and 0.85, and angles-of-attack between –3° and 4°. Four different mass-flow plugs were also tested to assess propulsor operating condition effects. Sensitivity to these flow conditions are analyzed in detail, especially in terms of the nacelle flow distortion which was the main subject of the study. Aerodynamic load coefficients, aftbody boundary-layer measurements and fuselage pressure tap results are also discussed, providing a wide range of validation results from this experimental campaign. This validation effort shows that current best-practices using RANS models within the LAVA solver flow solver are well suited for predicting the inlet flow distortion characteristics of novel aircraft configurations employing BLI at the aft end of the fuselage.

AATT↗