Alkali layered compounds interfaces for energy conversion and energy storage

During year one a new ultra-high vacuum, an Ar(+) ion sputterer, a low energy electron diffraction (LEED) system, an Auger electron spectrometer (AES), a work function measurement device with a Kelvin probe, and related accessories were used. The study found a focus in the adsorption of chalcogenides on Si and III-V compound semiconductors. In the second year, a scanning tunneling microscope was obtained along with a quadrapole mass spectrometer, power supplies, a computer, a chart recorder, etc. We started the systematic study on the adsorption of chalcogenides on the compound semiconductor surfaces. The third year saw the mounting of the scanning tunneling microscope (STM) on the existing UHV system. The investigation continued with the adsorption of Cs (alkali) on S-covered Si(100)2x1 surfaces. Then the adsorption of S on Cs-covered Si(100) surfaces was studied.

Papageorgopoulos, Chris A.↗

Assessment of Corona/Arcing Hazard for Electron Beam Welding in Space Shuttle Bay at LEO for ISWE: Test Results

Test welds were made in argon over a range of pressures from 10-5 to 10-3 torr (the latter pressure an order of magnitude above pressures anticipated in the space shuttle bay during welding) with and without plasma on 304 stainless steel, 6Al-4V titanium, and 5456 aluminum in search of any possible unwanted electrical discharges. Only a faint steady glow of beam-excited atoms around the electron beam and sometimes extending out into the vacuum chamber was observed. No signs of current spiking or of any potentially dangerous electrical discharge were found.

Nunes, A. C., Jr.↗

Extraterrestrial Radiation Chemistry and Molecular Astronomy

Astronomical observations of both solar system and interstellar regions have revealed a rich chemical inventory that includes most classes of organic molecules and selected inorganics. For example, gas-phase ethylene glycol and SOz have been observed by astronomers, while solidphase detections include OCS, H2O2 , and the cyanate anion.' All of these are found in environments that are, by earthly standards, exceedingly hostile: temperatures of 10 - 100 K, miniscule densities, and near-ubiquitous ionizing-radiation fields. Beyond the simplest chemical species, these conditions have made it difficult-to-impassible to account for the observed molecular abundances using gas-phase chemistry, suggesting solid-phase reactions play an important role. In extraterrestrial environments, cosmic rays, UV photons, and magnetospheric radiation all drive chemical reactions, even at cryogenic temperatures. To study this chemistry, radiation astrochemists conduct experiments on icy materials, frozen under vacuum and exposed to sources such as keV electrons and MeV protons. Compositional changes usually are followed with IR spectroscopy and, in selected cases, more-sensitive mass-spectral techniques. This talk will review some recent results on known and suspected extraterrestrial molecules and ions. Spectra and reaction pathways will be presented, and predictions made for interstellar chemistry and the chemistry of selected solar system objects. Some past radiation-chemical contributions, and future needs, will be explored.

Hudson, Reggie L.↗

Vacancy effects on the formation of helium and krypton cavities in 3-C-SiC irradiated and annealed at elevated temperatures

Polycrystalline 3C-SiC was sequentially irradiated at 400 and 750°C with 120 keV He 2+ and 4 MeV Kr 15+ ions to 10 17 and 41016 cm -2 , respectively. The Kr 15+ ions penetrated the entire depth of the He 2+ ion implantation region. Three areas of He 2+ , Kr 15+ and He 2+ + Kr 15+ ion implanted 3C-SiC were created through masked overlapping irradiations. The sample was subsequently annealed at 1600°C in vacuum and characterized using cross-sectional transmission electron microscopy and energy-dispersive x-ray spectroscopy. Compared to the He 2+ ion only implanted 3C-SiC, helium cavities in the He 2+ and Kr15+ co-implanted 3C-SiC had a smaller size but higher density. At 25 dpa, presence of He in the co-implanted 3C-SiC significantly promoted cavity growth; much smaller voids were formed in the Kr 15+ ion only irradiated 3C-SiC at the same dose. In addition, local Kr migration and trapping at cavities occurred, but long-range Kr diffusion in 3C-SiC was not observed up to 1600°C.

36 MATERIALS SCIENCE↗

THERMAL ANALYSIS OF THE RHIC ARC DIPOLE MAGNET COLD MASS WITH THE EIC BEAM SCREEN

The EIC will make use of the existing RHIC storage rings with their superconducting (SC) magnet arcs. A stain-less-steel beam screen with co-laminated copper and a thin amorphous carbon (aC) film on the inner surface will be installed in the beam pipe of the SC magnets. The copper will reduce the beam-induced resistive-wall (RW) heating from operation with the higher intensity EIC beams, that if not addressed would make the magnets quench. Limiting the RW heating is also important to achieve an adequately low vacuum level. The aC coating will reduce secondary electron yield which could also cause heating and limit in-tensity. Among all the RHIC SC magnets, the arc dipoles present the biggest challenge to the design and installation of beam screens. The arc dipoles, which make up for 78% (2.5 km) length of all SC magnets in RHIC, expect the larg-est RW heating due to their smallest aperture. These mag-nets are also the longest (9.45 m each), thus experiencing the largest temperature rise over their length, and have a large sagitta (48.5 mm) that increases the difficulty to in-stall the beam screen in place. This paper presents a de-tailed thermal analysis of the magnet-screen system.

43 PARTICLE ACCELERATORS↗

Ultraviolet (UV) light emitting device (LED) driven photocathode

An apparatus includes an electromechanical x-ray generator (MEXRAY) configured to charged capacitors using a small, high-voltage direct current. The apparatus also includes an ultraviolet (UV) light emitting diode (LED) driven photocathode device configured to control/modulate an electron dose rate of the MEXRAY or other vacuum DC, source.

Watson, Scott Avery↗

The Jefferson Lab VUV-FEL at 10 eV and above

We will present details of the vacuum ultraviolet performance of the Jefferson Lab Free Electron Laser. The JLab FEL is oscillator-based [1] and uses a superconducting energy recovered linac for CW RF operation at up to 75 MHz. Lasing at a fundamental wavelength of 372 nm, the third harmonic is at 124 nm, corresponding to a photon energy of 10 eV. The energy per pulse in the fundamental is 20 microJoules, which at 9 MHz yields an average power of 180 Watts. The pulses have a FWHM of order 300 fs, which essentially determines the optical bandwidth. The third harmonic, which is a 0.1 ? 1% fraction of this, is considerably brighter than any other source in the region. Further, being an FEL, there is a wide range of tunability in the 1 eV to 15 eV range. Additional reach is possible with increased electron beam energy, and some options will be discussed in the talk. We acknowledge funding from ONR, AFRL and DOE-BES under contract AC05-060R23177. [1]. S. Benson et al. Nucl. Instrum. Methods A582, 14-17 (2007).

Williams, Gwyn↗

Commissioning of the vacuum system of the KATRIN Main Spectrometer

The KATRIN experiment will probe the neutrino mass by measuring the β-electron energy spectrum near the endpoint of tritium β-decay. We performed an integral energy analysis by an electro-static spectrometer (``Main Spectrometer''), an ultra-high vacuum vessel with a length of 23.2 m, a volume of 1240 m 3 , and a complex inner electrode system with about 120 000 individual parts. The strong magnetic field that guides the β-electrons is provided by super-conducting solenoids at both ends of the spectrometer. Its influence on turbo-molecular pumps and vacuum gauges had to be considered. Furthermore, a system consisting of 6 turbo-molecular pumps and 3 km of non-evaporable getter strips has been deployed and was tested during the commissioning of the spectrometer. In this paper the configuration, the commissioning with bake-out at 300 °C, and the performance of this system are presented in detail. The vacuum system has to maintain a pressure in the 10 -11 mbar range. We demonstrated that the performance of the system is already close to these stringent functional requirements for the KATRIN experiment, which will start at the end of 2016.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

QED with the electron as a very small black-hole-like object

We pursue a simple semi-classical particle-based picture of QED in which the electron is assumed to contain a point massless and chargeless core that interacts with the electromagnetic vacuum in ways that are not dissimilar to the manner in which small black holes may interact with photons. Modifications are made to obtain known properties of the electron including the presence of rest energy, Lamb shift, magnetic moments (both free and bound), charge, Larmor emission, and vacuum polarization. The present study does not provide proofs but is rather an attempt to reverse-engineer the photon-electron and black-hole-electron interaction properties needed to match experimental observations. The ease by which many QED observables can be reproduced suggests further study of the presented framework may be warranted. Future detailed analysis of the exchange of long wavelength Hawking radiation between a pair of small black holes will be of particular interest.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Interferometric studies of the electron density dynamics at the periphery of a micropinch discharge

Results are presented from experimental studies of the electron density dynamics at the periphery of a low-inductance vacuum spark. The measurements were performed using a newly developed homodyne quadrature interferometer possessing fairly high dynamic range and performance. The experiments demonstrated the presence of a plasma with an electron density of n{sub e} {>=} 10{sup 18} cm{sup -3} at the periphery of the discharge gap. The radial electron density distribution was shown to have a pronounced tubular structure. The relatively high values of the peripheral electron density indicate that the process of pinching can be substantially affected by shunt currents flowing at the discharge periphery.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Prepulse effects on the generation of high energy electrons in fast ignition scheme

The energy distribution of the produced high energy electrons in the interaction of ultraintense picosecond laser pulses with high-Z solid targets is shown to be sensitive to the preformed plasma created by the prepulse and the amplified spontaneous emission pedestal. The created preformed plasmas, which are obtained by radiation hydrodynamic simulations for the present heating laser system at ILE, Osaka University, are seen to extend up to 30-100 mum just before the arrival of the main pulse. The dependences of the coupling efficiency of the laser energy to high energy electrons, and the energy spectra of these accelerated electrons, on this preformed plasma, are studied via a two-dimensional particle-in-cell simulation code. It is found that in a small preformed plasma case, JxB heating is dominant and the produced electron temperature agrees well with Haines' scaling law [Haines et al., Phys. Rev. Lett., 102, 045008 (2009)]. While in a large preformed plasma case, in addition to JxB heating and/or vacuum heating, other acceleration mechanisms, such as stochastic heating, can accelerate electrons to very high energies, carrying a significant fraction of input laser energy. Even after several picoseconds, the number of high energy electrons (0.5 MeV<E<5 MeV) generated in a small preformed plasma case can be several times larger than that of a large preformed plasma case.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interferometric studies of the electron density dynamics at the periphery of a micropinch discharge

Results are presented from experimental studies of the electron density dynamics at the periphery of a low-inductance vacuum spark. The measurements were performed using a newly developed homodyne quadrature interferometer possessing fairly high dynamic range and performance. The experiments demonstrated the presence of a plasma with an electron density of n{sub e} {>=} 10{sup 18} cm{sup -3} at the periphery of the discharge gap. The radial electron density distribution was shown to have a pronounced tubular structure. The relatively high values of the peripheral electron density indicate that the process of pinching can be substantially affected by shunt currents flowing at the discharge periphery.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of electron irradiation on large insulating surfaces used for European Communications Satellites

Samples of aluminized Kapton used for passive thermal control on the VHF shield and the antenna dish of ESA's OTS satellite and its derivatives were subjected to an incident electron beam of 25 keV and irradiated for 8 hours at room temperature and at -173 C under a vacuum of the 10 to the minus 6 th power torr. Visual observations during electron irradiation, measurements of leakage current and discharge characteristics, and material degradation following completion of irradiation are discussed.

Reddy, J.↗

Magnetic Field Measurement and Analysis for the Muon g-2 Experiment

The Muon g-2 Experiment (E989) at Fermilab measures the muon magnetic anomaly, aiming to resolve the greater than 3$\sigma$ discrepancy between the previous measurement and the Standard Model calculation with an improved precision of 140 part-per-billion (ppb). In E989, the muon beam is stored in a ring magnet. The spin precession frequency $\omega_{a}$ is measured by counting the decay positrons in 24 calorimeters, and the magnetic field is measured by nuclear magnet resonance (NMR) probes. An in-vacuum field scanning system consisting of NMR probes and read-out electronics has been implemented to measure the magnetic field applied to the muon beam. An additional 378 NMR probes, placed at fixed locations outside the vacuum chamber, monitor the field drift in between field scans. A high-accuracy probe was designed for calibrating the probes in the scanner. In this presentation, the magnetic field measurement hardware system and analysis methods will be described in detail. The progress of the Run-1 data analysis and improvements in Run-2 will be presented as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancing controllability and stability of bottom-gated graphene thin-film transistors by passivation with methylamine

This paper is intended to aid to bridge the gap between chemistry and electronic engineering. In this work, the fabrication of chemical vapour deposited graphene field-effect transistors employing silicon-nitride (Si{sub 3}N{sub 4}) gate dielectric is presented, showing originally p-type channel conduction due to ambient impurities yielding uncontrollable behaviour. Vacuum annealing has been performed to balance off hole and electron conduction in the channel, leading to the observation of the Dirac point and therefore improving controllability. Non-covalent functionalisation by methylamine has been performed for passivation and stability reasons yielding electron mobility of 4800 cm{sup 2}/V s and hole mobility of 3800 cm{sup 2}/V s as well as stabilised controllable behaviour of a bottom-gated transistor. The introduction of interface charge following the non-covalent functionalisation as well as the charge balance have been discussed and analysed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Photon sputtering of H2O ices: A preliminary report

A preliminary measurement of the total yields of ejected ions and electrons from H2O ices has been carried out using the He I 584 A resonance line as the incident photon beam. The H2O ices were prepared at 77 K in an ultrahigh vacuum system. The total yield of the ejected ion species and electrons was determined to be 8.8x10(exp -5) and 4.2x10(exp -4), respectively.

Wu, C. Y. Robert↗

A Seemingly Simple Task: Filling a Solenoid Volume in Vacuum with Dense Plasma

Space-charge neutralization of a pulsed, high-current ion beam is required to compress and focus the beam on a target for warm dense matter physics or heavy ion fusion experiments. We described attempts to produce dense plasma in and near the final focusing solenoid through which the ion beam travels, thereby providing an opportunity for the beam to acquire the necessary charge-compensating electrons. Among the options are plasma injection from four pulsed vacuum arc sources located outside the solenoid, and using a high current (> 4 kA) pulsed vacuum arc plasma from a ring cathode near the edge of the solenoid. The plasma distribution is characterized by photographic means and by an array of movable Langmuir probes. The plasma is produced at several cathode spots distributed azimuthally on the ring cathode. Beam neutralization and compression are accomplished, though issues of density, uniformity, and pulse-to-pulse reproducibly remain to be solved.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Structure and orientation of small particles of platinum deposited on NaCl and mica

The structure of small platinum particles condensed in vacuum onto NaCl (001), NaCl (111) and mica substrates was studied by electron diffraction and electron microscopy. Results show that above a certain substrate temperature decahedral or icosahedral particles are formed. These particles are practically absent with substrates cleaved in high vacuum. They are always much less numerous than in gold films prepared under the same conditions. Assumptions made to explain this phenomenon are: (1) the initial growth of an abnormal structure of the nuclei as opposed by the substrate; (2) the particles disappear before they attain a size which corresponds to the observations; and (3) the particles result from a coalescence mechanism leading to multiple twinned particles.