Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “traces”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Making Intercontinental Burning Influences Quantitative: Lessons on Transport and Geochemistry From the 3-D Simulation of CO in PEM-T A and TRACE-A

We report on two aspects of the simulation of global transport of plumes originating from subtropical biomass fires. We use of meteorological assimilation (MM5) at 2-degree resolution with a Grail cloud parameterization and a Blackadar-based planetary boundary layer parameterization. Ames's GRACES model provides emissions, transport, and an appropriate level of simulated chemical transformation. We have worked with passive-tracer CO or linear chemistry. This is appropriate since we find major work to be done in evaluating CO source strengths and transport mechanisms before chemical integrations could be meaningful. First, we present mechanisms by which CO and other pollutants are introduced into the free troposphere, and are then transported with hate dilution from approx. 0 to approx. 180 degrees longitude. One principal conduit for these plumes is the vernal subtropical jet; however the plumes appear at various altitudes and latitudes as they influenced by frontal motions and (most likely) radiative processes. A common, repeated pattern of transport has pollutant plumes arriving in the distant Pacific Ocean from Africa and South America at 25 degrees south and 14 km altitude. Following this, there is then a general appearance of pollution at extending down to 5 kin at more equatorial (10 S) and polar latitudes (to 45 S). Second, we evaluate the quantitative success of our simulation. (Such success requires efforts considerably beyond trajectory analyses, and is necessary for our community to claim an understanding of the effects of biomass burning on global atmospheric chemistry and the planet's trend in oxidizing capacity.) We find that we simulate most pollution episodes sampled by Glenn Sachse's CO instrument and the Blake hydrocarbon analyses during PENT A. We will present our current ideas on why our general levels appear satisfactory when the observations are within 20 ppb of background levels, but substantially miss the variability associated with the most intense biomass burning plumes. As time allows, we will speculate on the origins of a class of plumes that appear in the mid-troposphere, but are missing from our simulations.

Chatfield, Robert↗

Sampling of Trace Atmospheric Constituents Above the Surface of Mars from a Montgolfiere Balloon

We suggest that use of an aerially deployed, solar-heated balloon, or Montgolfiere, during a Martian polar summer could provide an optimal platform for atmospheric measurements near the surface. Solar Montgolfieres are empty balloons with a hole in the bottom that fill with ambient atmosphere while failing and are rapidly heated in by the sun, thus providing buoyancy. Such a balloon would be driven by the Martian winds in the constant sunlight of a high latitude entry and could provide a traverse of thousands of kilometers. It would encircle the Martian north polar region over a period,likely lasting over one earth month, and its altitude could be controlled as low as 100 meters to as high as 4000 meters above the surface. The significant payload of tens of kilograms allowed by this technology could readily accommodate the mass of instrumentation and the power source needed for a sensitive search for disequilibrium species that might provide the atmospheric signature of localized subsurface biological or geological activity. A mass spectrometer used in combination with gas enrichment techniques can provide sensitivities to sub parts per billion for several species of interest. Additional highly specific and sensitive detectors can search for other species or measurements of their mixing ratio variation along the path of the balloon. It would be useful to combine these atmospheric measurements with electromagnetic sounding to search for variations in subsurface conductivity that might indicate the presence of subsurface water. After a month of operation, the balloon could also soft land the DBMS to provide additional data on soil samples from a 1-2 meter subsurface drill. In order to float a 30-kg payload at altitudes between 100 m and 4000 m above the Martian north polar surface, an aluminized polyethylene Montgolfiere would be approximately 29 meters in diameter and have a mass of 27 kg. Altitude variations could be accomplished by means of an upper vent to release hot gas, as has been tested at JPL, or be means of a simple, internal winch mechanism to decrease the volume of the balloon. JPL has successfully deployed three polyethylene Montgolfieres at 4-6 mbar pressure in the Earth's stratosphere and will be deploying a 20-m diameter polyethylene Montgolfiere later in 2001.

Jones, Jack A.↗

Measurements of Oxygenated Organic Chemicals In the Pacific Troposphere During TRACE-P: Higher Aldehydes (less than C(sub 1)), Their Sources, and Potential Role In Atmospheric Oxidation

Airborne measurements of a large number of oxygenated organics were carried out in the Pacific troposphere (to 12 km) in the Spring of 2001 (Feb. 24-April 10). Specifically these measurements included acetaldehyde, propanaldehyde, acetone, methylethyl ketone, methanol, ethanol, PAM and organic nitrates. Independent measurements of formaldehyde, peroxides, and tracers were also available. Highly polluted as well as pristine air masses were sampled. Oxygenated organics were abundant in the clean In troposphere and were greatly enhanced in the outflow regions from Asia. Extremely high concentrations of aldehydes could be measured in the troposphere. It is not possible to explain the large abundances of aldehydes in the background troposphere without invoking significant oceanic sources. A strong correlation between the observed mixing ratios of formaldehyde and acetaldehyde is present. We infer that higher aldehydes (such as acetaldehyde and propanaldehyde) may provide a large source of formaldehyde and sequester Cox throughout the troposphere. The atmospheric behavior of acetone, methylethyl ketone, and methanol is generally indicative of their common terrestrial sources with a Image contribution from biomass/biofuel burning. A vast body of data has been collected and it is being analyzed both statistically and with the help of models to better understand the role that oxygenated organics play in the atmosphere and to unravel their sources and sinks. These results will be presented.

Singh, Hanwant B.↗

Tropospheric Trace Gas Interactions with Aerosols

Tropospheric aerosols are of considerable environmental importance. They modify the radiative budget of Earth by scattering and absorbing radiation, and by providing nuclei for cloud formation. Additionally, they provide surfaces for heterogeneous and multiphase reactions that affect tropospheric chemistry. For example, Dentener and Crutzen (1993) showed that reactions of N2O5 and NO3 with sulfate aerosols may significantly alter the tropospheric concentrations of NO(x), O3, and OH by converting NOx to HNO3 which is rapidly removed by precipitation. Zhang et al. (1994) assumed these same reactions would occur on dust aerosols and showed that dust outbreaks may reduce NO(x) levels by up to 50%. Dentener et al. (1996) studied the possible effect of reactions on dust on sulfate, nitrate, and O3 concentration. Heterogeneous and multiphase reactions on aerosols may also perturb the sulfur cycle the chlorine cycle and the bromine cycle. Because these reactions can release free chlorine and free bromine they might lead to the destruction of ozone in the marine boundary layer that may be important to include in models of tropospheric chemistry. The goal of our proposed work is to examine the role of heterogeneous and multiphase reactions in the tropospheric cycles of reactive nitrogen and sulfur.

Penner, Joyce E.↗

Trace Gas Monitoring

Space technology is contributing to air pollution control primarily through improved detectors and analysis methods. Miniaturized mass spectrometer is under development to monitor vinyl chloride and other hydrocarbon contaminants in an airborne laboratory. Miniaturized mass spectrometer can be used to protect personnel in naval and medical operations as well as aboard aircraft.

Source record↗

Satellite-Based Stratospheric and Tropospheric Measurements: Determination of Global Ozone and Other Trace Species

This grant is an extension to our previous NASA Grant NAG5-3461, providing incremental funding to continue GOME (Global Ozone Monitoring Experiment) and SCIAMACHY (SCanning Imaging Absorption SpectroMeter for Atmospheric CHartographY) studies. This report summarizes research done under these grants through December 31, 2002. The research performed during this reporting period includes development and maintenance of scientific software for the GOME retrieval algorithms, consultation on operational software development for GOME, consultation and development for SCIAMACHY near-real-time (NRT) and off-line (OL) data products, and participation in initial SCIAMACHY validation studies. The Global Ozone Monitoring Experiment was successfully launched on the ERS-2 satellite on April 20, 1995, and remains working in normal fashion. SCIAMACHY was launched March 1, 2002 on the ESA Envisat satellite. Three GOME-2 instruments are now scheduled to fly on the Metop series of operational meteorological satellites (Eumetsat). K. Chance is a member of the reconstituted GOME Scientific Advisory Group, which will guide the GOME-2 program as well as the continuing ERS-2 GOME program.

Chance, Kelly↗

Measurement of Peroxyacetyl Nitrate (PAN), Peroxypropionyl Nitrate (PPN) and Peroxymethacryloyl Nitrate (MPAN) during TRACE-P

In Fall 2000, the PANs gas chromatograph (GC) was improved and prepared for installation on the NASA P-3. A number of experiments were conducted in conjunction with the NCAR NO,, instrument (B. Ridley) to settle some of the fine details of the output of the calibration system for each instrument. In addition, the sampling frequency was improved.

Flocke, Frank↗

Mid-infrared difference-frequency generation source pumped by 1.1-1.5 micrometer dual-wavelength fiber amplifier for trace-gas detection

Continuous-wave mid-infrared radiation near 3.5 micrometers is generated by difference-frequency mixing of the output of a compact 1.1-1.5 micrometer dual-wavelength fiber amplifier in periodically poled LiNbO3. The diode side-pumped amplifier is constructed with double-cladding Yb-doped fiber followed by single-mode Er/Yb codoped fiber. Output powers of as much as 11 microW at 3.4 micrometers are obtained, and spectroscopic detection of CH4 and H2CO is demonstrated. c 1998 Optical Society of America.

Non-NASA Center↗

Portable fiber-coupled diode-laser-based sensor for multiple trace gas detection

Tunable narrowband mid-infrared radiation from 3.25 to 4.4 micrometers is generated by a compact fiber-coupled, difference-frequency-based spectroscopic source. A 20-mW external cavity diode laser (with a tuning range from 814 to 870 nm) and a 50-mW distributed-Bragg-reflector diode-laser-seeded ytterbium-doped fiber amplifier operating at 1083 nm are difference-frequency mixed in a multi-grating, temperature-controlled periodically poled LiNbO3 crystal. A conversion efficiency of 0.44 mW/(W2cm) (corresponding to a power of approximately equal to 3 microW at 3.3 micrometers) represents the highest conversion efficiency reported for a portable device. Performance characteristics of such a sensor and its application to spectroscopic detection of CO2, N2O, H2CO, HCl, NO2, and CH4 will be reported in this work.

Non-NASA Center↗

Tropospheric Modeling Studies of TRACE-P Data: Investigations of the HO(x)/NO(x)/O3 Photochemical System and Its Coupling to Sulfur/Aerosol Species

During the duration of the NASA Grant NCC1-01-24, members of research team consisted of: D. Davis, G. Chen, S. Liu, C. Song, B. DiNunno, J. Nowak, and X. Gong. The major goal of our group effort was that of analyzing data from several NASA field studies and then preparing manuscripts for publication reflecting these analyses. Many of the papers so published were initiated by members of the Davis group; however, for a great many others one or more group members assisted other PI'S in writing their manuscripts. Both types of manuscripts are listed below as representing the final product from this grant.

Davis, Douglas D.↗

Fractal analysis of heart rate dynamics as a predictor of mortality in patients with depressed left ventricular function after acute myocardial infarction. TRACE Investigators. TRAndolapril Cardiac Evaluation

A number of new methods have been recently developed to quantify complex heart rate (HR) dynamics based on nonlinear and fractal analysis, but their value in risk stratification has not been evaluated. This study was designed to determine whether selected new dynamic analysis methods of HR variability predict mortality in patients with depressed left ventricular (LV) function after acute myocardial infarction (AMI). Traditional time- and frequency-domain HR variability indexes along with short-term fractal-like correlation properties of RR intervals (exponent alpha) and power-law scaling (exponent beta) were studied in 159 patients with depressed LV function (ejection fraction <35%) after an AMI. By the end of 4-year follow-up, 72 patients (45%) had died and 87 (55%) were still alive. Short-term scaling exponent alpha (1.07 +/- 0.26 vs 0.90 +/- 0.26, p <0.001) and power-law slope beta (-1.35 +/- 0.23 vs -1.44 +/- 0.25, p <0.05) differed between survivors and those who died, but none of the traditional HR variability measures differed between these groups. Among all analyzed variables, reduced scaling exponent alpha (<0.85) was the best univariable predictor of mortality (relative risk 3.17, 95% confidence interval 1.96 to 5.15, p <0.0001), with positive and negative predictive accuracies of 65% and 86%, respectively. In the multivariable Cox proportional hazards analysis, mortality was independently predicted by the reduced exponent alpha (p <0.001) after adjustment for several clinical variables and LV function. A short-term fractal-like scaling exponent was the most powerful HR variability index in predicting mortality in patients with depressed LV function. Reduction in fractal correlation properties implies more random short-term HR dynamics in patients with increased risk of death after AMI.

Non-NASA Center↗

Background contamination by coplanar polychlorinated biphenyls (PCBs) in trace level high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS) analytical procedures

The addition of the "dioxin-like" polychlorinated biphenyl (PCB) congeners to the assessment of risk associated with the 2,3,7,8-chlorine substituted dioxins and furans has dramatically increased the number of laboratories worldwide that are developing analytical procedures for their detection and quantitation. Most of these procedures are based on established sample preparation and analytical techniques employing high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS), which are used for the analyses of dioxin/furans at low parts-per-trillion (ppt) levels. A significant and widespread problem that arises when using these sample preparation procedures for the analysis of coplanar PCBs is the presence of background levels of these congeners. Industrial processes, urban incineration, leaking electrical transformers, hazardous waste accidents, and improper waste disposal practices have released appreciable quantities of PCBs into the environment. This contamination has resulted in the global distribution of these compounds via the atmosphere and their ubiquitous presence in ambient air. The background presence of these compounds in method blanks must be addressed when determining the exact concentrations of these and other congeners in environmental samples. In this study reliable procedures were developed to accurately define these background levels and assess their variability over the course of the study. The background subtraction procedures developed and employed increase the probability that the values reported accurately represent the concentrations found in the samples and were not biased due to this background contamination.

Polychlorinated Biphenyls/analysis/metabolism↗

Spatial Variation of Methane and Other Trace Gases Detected on Mars: Interpretation with a General Circulation Model

Several teams have recently reported the detection of methane in the Martian atmosphere [1-3]. Although the detection is at the limit of the instrument capacities, one of the most surprising findings by some of these teams is the apparent strong spatial variations observed in spite of the fact that a gas like methane was expected to have a relatively long lifetime in the Martian atmosphere and thus be well mixed. To better quantitatively understand how such spatial variations can form on Mars, we have performed multiple realistic 3D general circulation model simulations in which gases with different sources, lifetime or sinks are released and transported in the Martian atmosphere.

Forget, F.↗

Liquid Propellant Tracing Impingement Injector

An injector for use with the rocket thruster has a plurality of fuel ports separated from a plurality of oxidizer ports. The oxidizer and fuel ports are paired together directing their respective fluids along a path with radial and tangential components so that the two fluids impinge at a predetermined spaced apart distance from the chamber wall of the combustion chamber at an impingement track. By providing the fuel at a steeper angle relative to the chamber walls than the oxidizer, the fuel can be utilized to provide a fuel rich zone near the chamber walls to assist in cooling the chamber walls during operation.

George D Xenofos↗