Instrument interface description for NOAA 2000 instruments with European morning spacecraft and/or NOAA-OPQ spacecraft

The purpose is to describe at a high level the common interface provisions and constraints placed on the NOAA-2000 instruments and the interfacing spacecraft elements in the following areas: electrical interface, mechanical interface, thermal interface, magnetic interface, electromagnetic compatibility, structural/mechanical environmental interface, contamination control, and the ionizing radiation environment. The requirements reflect the fact that these instruments must be compatible with a number of different polar orbiting satellite vehicles including the NOAA-OPQ satellites and the EUMETSAT METOP satellites.

Source record↗

BeyondPlanck: I. Global Bayesian analysis of the Planck Low Frequency Instrument data

We describe the BEYONDPLANCK project in terms of our motivation, methodology, and main products, and provide a guide to a set of companion papers that describe each result in more detail. Building directly on experience from ESA’s Planck mission, we implemented a complete end-to-end Bayesian analysis framework for the Planck Low Frequency Instrument (LFI) observations. The primary product is a full joint posterior distribution P(ω | d), where ω represents the set of all free instrumental (gain, correlated noise, bandpass, etc.), astrophysical (synchrotron, free-free, thermal dust emission, etc.), and cosmological (cosmic microwave background – CMB – map, power spectrum, etc.) parameters. Some notable advantages of this approach compared to a traditional pipeline procedure are seamless end-to-end propagation of uncertainties; accurate modeling of both astrophysical and instrumental effects in the most natural basis for each uncertain quantity; optimized computational costs with little or no need for intermediate human interaction between various analysis steps; and a complete overview of the entire analysis process within one single framework. As a practical demonstration of this framework, we focus in particular on low-ℓ CMB polarization reconstruction with Planck LFI. In this process, we identify several important new effects that have not been accounted for in previous pipelines, including gain over-smoothing and time-variable and non-1/f correlated noise in the 30 and 44 GHz channels. Modeling and mitigating both previously known and newly discovered systematic effects, we find that all results are consistent with the ΛCDM model, and we constrained the reionization optical depth to τ = 0.066 ± 0.013, with a low-resolution CMB-based χ 2 probability to exceed of 32%. This uncertainty is about 30% larger than the official pipelines, arising from taking a more complete instrumental model into account. The marginal CMB solar dipole amplitude is 3362.7 ± 1.4 μK, where the error bar was derived directly from the posterior distribution without the need of any ad hoc instrumental corrections. We are currently not aware of any significant unmodeled systematic effects remaining in the Planck LFI data, and, for the first time, the 44 GHz channel is fully exploited in the current analysis. We argue that this framework can play a central role in the analysis of many current and future high-sensitivity CMB experiments, including LiteBIRD, and it will serve as the computational foundation of the emerging community-wide COSMOGLOBE effort, which aims to combine state-of-the-art radio, microwave, and submillimeter data sets into one global astrophysical model.

79 ASTRONOMY AND ASTROPHYSICS↗

Cloud Droplet Measurement System for the ARM Tethered Balloon System (TBS) Field Campaign Report

The Mesa Photonics' cloud droplet measurement system (CDMS) performs in situ measurement of droplet size distribution and droplet number density in clouds. These characteristics are important cloud microphysical properties that are critical input parameters for atmospheric models and are also useful for proper calibration and validation of performance of other atmospheric measurement instrumentation. This small campaign was the first project (out of two) that involved integration of the CDMS into the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility’s tethered balloon system (TBS) and its initial testing at the ARM Southern Great Plains (SGP) atmospheric observatory. The follow-up campaign (AFC07016) involved testing of the CDMS under relevant conditions at the third ARM Mobile Facility (AMF3) at Oliktok Point, Alaska and making in situ measurements in clouds. The goal of this small field campaign was to deploy the CDMS on the ARM TBS, demonstrate its integrity and compatibility with the TBS, and test the wireless telecommunication system in preparation for subsequent in-cloud measurements at ARM’s North Slope of Alaska (NSA) observatory at Utqiagvik (formerly Barrow). The specific technical objectives included: (1) Integration of the Mesa Photonics' CDMS into the ARM TBS, (2) testing of the wireless telecommunication system of the CDMS, (3) evaluating the data acquisition software and image processing algorithms especially under high-background-illumination conditions, and (4) testing the ruggedness of the instrument's optical alignment and other performance characteristics. All objectives have been successfully met. The mounting hardware was designed and built mostly at Sandia National Laboratories (SNL), which allowed reliable mounting of the CDMS on the TBS and co-locating the CDMS with other instruments. The field tests were performed by the principal investigator (PI) in collaboration with the TBS operational crew led by D. Dexheimer. The field testing demonstrated good compatibility of the CDMS with the TBS. During the TBS flights, the crew did not experience any operational issues with the CDMS. The instrument demonstrated reliable operational characteristics, including sufficient battery life and good thermal management. The wireless telecommunication system has been successfully tested at TBS flight altitudes of up to 1000 m. During all flights, the CDMS raw data were wirelessly transmitted to the ground station and processed in real time. The ruggedness of the instrument's optical alignment was evaluated by performing calibration of the CDMS (using Mesa Photonics' fixed-size monodisperse droplet generator) before and after the campaign. The calibration was stable within the instrument's measurement precision. In summary, the campaign demonstrated good compatibility of the Mesa Photonics' CDMS with the ARM TBS. The flight tests confirmed the mechanical integrity of the CDMS and stability of its optical layout, as well as reliability of the wireless telecommunication system. Successful completion of this campaign provided a solid basis for the next campaign (AFC07016, November 2020), that involved testing of the CDMS during in-cloud TBS flights at AMF3 at Oliktok Point.

54 ENVIRONMENTAL SCIENCES↗

Spacelab 2 pointed experiments

Thirteen experiments have been selected for development for the multidisciplinary Spacelab 2 mission. They include three solar physics instruments and an atmospheric physics investigation mounted on the Instrument Pointing System (IPS), a two-axis gimballed X-ray experiment, an infrared telescope scanned about a single axis, and several fixed instruments. Integration of the IPS with its instruments and integration of the entire experiment complement into a flight mission has been a most demanding, complex task which has evolved as the Shuttle carrier vehicle, Spacelab, the IPS, and the experiments have matured. Mechanical interactions between all of these elements, thermal design restrictions, Shuttle and IPS operational constraints, mission duration, pointed instrument collision avoidance, and many other factors have impacted the scientific and engineering objectives of all of the experiments. Not all of the impacts have been adverse, however, and four types of joint science between previously unrelated experiments have so far been generated. This paper summarizes the current state of mission planning, particularly as it relates to the achievement of the scientific and engineering objectives of the pointed experiments. It discusses some of the compromises that have been made to satisfy the diverse requirements and capabilities of the hardware, the planning to date for joint solar observations from the IPS, and some system problems which remain.

Urban, E. W.↗

WF/PC internal molecular contamination during system thermal-vacuum test

During the recent system thermal vacuum test of the Wide-Field/Planetary Camera (WF/PC), instrumentation was added to the WF/PC to characterize the internal molecular contamination and verify the instrument throughput down to 1470 angstroms. Analysis of data elements revealed two contaminants affecting the far-ultraviolet (FUV) performance of the WF/PC. The one contaminant (heavy volatile) is correlated with the electronic and housing temperature, and the contamination is significantly reduced when the electronics are operated below plus 8 degrees to plus 10 degrees C. The other contaminant (light volatile) is controlled by the heat pipe temperature, and the contamination is significantly reduced when the Thermal Electric Cooler (TEC) hot-junction temperature is below minus 40 degrees to minus 50 degrees C. The utility of contamination sensors located behind instruments during system tests was demonstrated.

Taylor, Daniel M.↗

Implications of high-spatial-resolution thermal infrared (Termoskan) data for Mars landing site selection

Thermal infrared observations of Mars from spacecraft provide physical information about the upper thermal skin depth of the surface, which is on the order of a few centimeters in depth and thus very significant for lander site selection. The Termoskan instrument onboard the Soviet Phobos '88 spacecraft acquired the highest spatial-resolution thermal infrared data obtained for Mars, ranging in resolution from 300 m to 3 km per pixel. It simultaneously obtained broadband reflected solar flux data. Although the 6 deg N - 30 deg S Termoskan coverage only slightly overlaps the nominal Mars Pathfinder target range, the implications of Termoskan data for that overlap region and the extrapolations that can be made to other regions give important clues for optimal landing site selection.

Betts, Bruce H.↗

Active CryoCubeSat

The Active CryoCubeSat project will demonstrate an advanced thermal control system for a 6-Unit (6U) CubeSat platform. A miniature, active thermal control system, in which a fluid is circulated in a closed loop from thermal loads to radiators, will be developed. A miniature cryogenic cooler will be integrated with this system to form a two-stage thermal control system. Key components will be miniaturized by using advanced additive manufacturing techniques resulting in a thermal testbed for proving out these technologies. Previous CubeSat missions have not tackled the problem of active thermal control systems nor have any past or current CubeSat missions included cryogenic instrumentation. This Active CryoCubeSat development effort will provide completely new capacities for CubeSats and constitutes a major advancement over the state-of-the-art in CubeSat thermal control.

CubeSat↗

Comparison of laboratory calibrations of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) at the beginning and end of the first flight season

Spectral and radiometric calibrations of AVIRIS are described together with changes in instrument characteristics that occurred during the flight season. These changes include detachment of the optical fibers to two of the four AVIRIS spectrometers, degradation in the optical alignment of the spectrometers due to thermally induced and mechanical warpage, and breakage of a thermal blocking filter in one of the spectrometers. Means of improving the instrument are discussed.

Vane, Gregg↗

Principal Component Noise Filtering for NAST-I Radiometric Calibration

The National Polar-orbiting Operational Environmental Satellite System (NPOESS) Airborne Sounder Testbed- Interferometer (NAST-I) instrument is a high-resolution scanning interferometer that measures emitted thermal radiation between 3.3 and 18 microns. The NAST-I radiometric calibration is achieved using internal blackbody calibration references at ambient and hot temperatures. In this paper, we introduce a refined calibration technique that utilizes a principal component (PC) noise filter to compensate for instrument distortions and artifacts, therefore, further improve the absolute radiometric calibration accuracy. To test the procedure and estimate the PC filter noise performance, we form dependent and independent test samples using odd and even sets of blackbody spectra. To determine the optimal number of eigenvectors, the PC filter algorithm is applied to both dependent and independent blackbody spectra with a varying number of eigenvectors. The optimal number of PCs is selected so that the total root-mean-square (RMS) error is minimized. To estimate the filter noise performance, we examine four different scenarios: apply PC filtering to both dependent and independent datasets, apply PC filtering to dependent calibration data only, apply PC filtering to independent data only, and no PC filters. The independent blackbody radiances are predicted for each case and comparisons are made. The results show significant reduction in noise in the final calibrated radiances with the implementation of the PC filtering algorithm.

Tian, Jialin↗

Landsat 9 Mission Update and Status

Landsat 9 is currently undergoing testing at the integrated observatory level in preparation for launch from Vandenberg Air Force Base in 2021. Landsat 9 will replace Landsat 7 in orbit, 8 days out of phase with Landsat 8. Landsat 9 is largely a copy of Landsat 8 in terms of instrumentation, with an Operational Land Imager (OLI), model #2 and a Thermal Infrared Sensor (TIRS), model #2. The TIRS-2 is more significantly changed from TIRS with increased redundancy, as well as changes to the telescope baffling to improve stray light control and a revised scene select mirror encoder mechanism. Data quality of the Landsat 9 instruments is comparable to, or better than the Landsat 8 ones, with an increase to 14 bits of data transmitted and more detailed pre-launch characterization for OLI-2, and with more detailed characterization of the TIRS-2 pre-launch, in addition to the improved stray light control. The performance of the two instruments is summarized and compared to that of the Landsat 8 instruments.

Brian Markham↗

Landsat 9 pre-launch sensor characterization and comparison with Landsat 8 results

Landsat 9 is planned for launch in December 2020 to continue the mission of observing changes on the Earth’s surface that began in 1972 with the launch of Landsat 1. Like Landsat 8, Landsat 9 will carry two imaging instruments: Operational Land Imager 2 (OLI-2), designed and built by Ball Aerospace, and Thermal Infrared Sensor 2 (TIRS-2), manufactured by NASA Goddard Space Flight Center (GSFC). As of this writing, both sensors have completed the instrument-level ground testing and are ready for integration into the spacecraft. Data collected during the pre-launch performance testing are analyzed to assess the usability of responses of the video reference pixels (VRPs)located on the focal planes of OLI-2 and Landsat 8 OLI for more accurate detector bias estimates, develop a methodology to correct for nonlinearities in the OLI-2 response and compare it to the OLI correction approach, and determine the spatial performance of TIRS-2.

Esad Micijevic↗

A Simplified Model of VIPER Thermal Management System. Part I: Loop Heat Pipe

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) uses a combination of loop heat pipes (LHPs) and heaters as the primary hardware to modulate the temperature of the electronic boxes and payloads instruments. LHPs have been designed and instrumented to be capable of passive and active shutdown. The goal of the passive shutdown, using a thermal control valve (TCV) to limit the flow of the working fluid, is to preserve thermal energy and avoid unnecessary heat leaks during lunar night. The goal of the active shutdown on the other hand, is to forcefully increase the vehicle internal temperature to bakeout the payload instruments. Several numerical modeling tools are available to analyze LHP performance under the complex set of operational requirements and environments levied on the VIPER Thermal Management System (TMS). Yet, while those numerical modeling tools are capable of detailed performance analysis, they tend to take large computational resources and long computational time. In this paper, a model of a single LHP developed based on control volume approach is presented. By using the control volume approach, the complex geometry of the LHP, and the components attached to it, are reduced to thermal lump capacitances, thus reducing the computation effort. This paper also describes the effort to correlate the proposed LHP model using thermal vacuum (TVAC) test data.

Loop Heat Pipe↗

A Simplified Model of VIPER Thermal Management System. Part I: Loop Heat Pipe

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) uses a combination of loop heat pipes (LHPs) and heaters as the primary hardware to modulate the temperature of the electronic boxes and payloads instruments. LHPs have been designed and instrumented to be capable of passive and active shutdown. The goal of the passive shutdown, using a thermal control valve (TCV) to limit the flow of the working fluid, is to preserve thermal energy and avoid unnecessary heat leaks during lunar night. The goal of the active shutdown on the other hand, is to forcefully increase the vehicle internal temperature to bakeout the payload instruments. Several numerical modeling tools are available to analyze LHP performance under the complex set of operational requirements and environments levied on the VIPER Thermal Management System (TMS). Yet, while those numerical modeling tools are capable of detailed performance analysis, they tend to take large computational resources and long computational time. In this paper, a model of a single LHP developed based on control volume approach is presented. By using the control volume approach, the complex geometry of the LHP, and the components attached to it, are reduced to thermal lump capacitances, thus reducing the computation effort. This paper also describes the effort to correlate the proposed LHP model using thermal vacuum (TVAC) test data.

Loop Heat Pipe↗

Terra and Aqua MODIS Thermal Emissive Bands On-Orbit Calibration and Performance

Since launch, the Moderate Resolution Imaging Spectroradiometer (MODIS) instruments on the Terra and Aqua spacecraft have operated successfully for more than 14 and 12 years, respectively. A key instrument for National Aeronautics and Space Administration Earth Observing System missions, MODIS was designed to make continuous observations for studies of Earth's land, ocean, and atmospheric properties and to extend existing data records from heritage Earth observing sensors. The 16 thermal emissive bands (TEBs) (3.75-14.24 micrometers) are calibrated on orbit using a temperature controlled blackbody (BB). Both Terra and Aqua MODIS BBs have displayed minimal drift over the mission lifetime, and the seasonal variations of the BB temperature are extremely small in Aqua MODIS. The long-term gain and noise equivalent difference in temperature performance of the 160 TEB detectors on both MODIS instruments have been well behaved and generally very stable. Small but noticeable variations of Aqua MODIS bands 33-36 (13.34-14.24 micrometer) response in recent years are primarily due to loss of temperature control margin of its passive cryoradiative cooler. As a result, fixed calibration coefficients, previously used by bands when the BB temperature is above their saturation temperatures, are replaced by the focal-plane-temperature-dependent calibration coefficients. This paper presents an overview of the MODIS TEB calibration, the on-orbit performance, and the challenging issues likely to impact the instruments as they continue operating well past their designed lifetime of six years.

TEBs↗

Advanced very high resolution radiometer

The program covered the design, construction, and test of a Breadboard Model, Engineering Model, Protoflight Model, Mechanical/Structural Model, and a Life Test Model. Special bench test and calibration equipment was also developed for use on the program. Initially, the instrument was to operate from a 906 n.mi. orbit and be thermally isolated from the spacecraft. The Breadboard Model and the Mechanical/Structural Model were designed and built to these requirements. The spacecraft altitude was changed to 450 n.mi., IFOVs and spectral characteristics were modified, and spacecraft interfaces were changed. The final spacecraft design provided a temperature-controlled Instrument Mounting Platform (IMP) to carry the AVHRR and other instruments. The design of the AVHRR was modified to these new requirements and the modifications were incorporated in the Engineering Model. The Protoflight Model and the Flight Models conform to this design.

Source record↗

Microgravity Transport Phenomena Experiment (MTPE) Overview

The Microgravity Transport Phenomena Experiment (MTPE) is a fluids experiment supported by the Fundamentals in Biotechnology program in association with the Human Exploration and Development of Space (BEDS) initiative. The MTP Experiment will investigate fluid transport phenomena both in ground based experiments and in the microgravity environment. Many fluid transport processes are affected by gravity. Osmotic flux kinetics in planar membrane systems have been shown to be influenced by gravimetric orientation, either through convective mixing caused by unstably stratified fluid layers, or through a stable fluid boundary layer structure that forms in association with the membrane. Coupled transport phenomena also show gravity related effects. Coefficients associated with coupled transport processes are defined in terms of a steady state condition. Buoyancy (gravity) driven convection interferes with the attainment of steady state, and the measurement of coupled processes. The MTP Experiment measures the kinetics of molecular migration that occurs in fluids, in response to the application of various driving potentials. Three separate driving potentials may be applied to the MTP Experiment fluids, either singly or in combination. The driving potentials include chemical potential, thermal potential, and electrical potential. Two separate fluid arrangements are used to study membrane mediated and bulk fluid transport phenomena. Transport processes of interest in membrane mediated systems include diffusion, osmosis, and streaming potential. Bulk fluid processes of interest include coupled phenomena such as the Soret Effect, Dufour Effect, Donnan Effect, and thermal diffusion potential. MTP Experiments are performed in the Microgravity Transport Apparatus (MTA), an instrument that has been developed specifically for precision measurement of transport processes. Experiment fluids are contained within the MTA fluid cells, designed to create a one dimensional flow geometry of constant cross sectional area, and to facilitate fluid filling and draining operations in microgravity. The fluid cells may be used singly for bulk solutions, or in a Stokes diaphragm configuration to investigate membrane mediated phenomena. Thermal and electrical driving potentials are applied to the experiment fluids through boundary plates located at the ends of the fluid cells. In the ground based instrument, two constant temperature baths circulate through reservoirs adjacent to the boundary plates, and establish the thermal environment within the fluid cells. The boundary plates also serve as electrodes for measurement and application of electrical potentials. The Fluid Manipulation System associated with the MTA is a computer controlled system that enables storage and transfer of experiment fluids during on orbit operations. The system is used to automatically initiate experiments and manipulate fluids by orchestrating pump and valve operations through scripted sequences. Unique technologies are incorporated in the MTA for measurement of fluid properties. Volumetric Flow Sensors have been developed for precision measurement of total fluid volume contained within the fluid cells over time. This data is most useful for measuring the kinetics of osmosis, where fluid is transported from one fluid cell to another through a semipermeable membrane. The MicroSensor Array has been designed to perform in situ measurement of several important fluid parameters, providing simultaneous measurement of solution composition at multiple locations within the experiment fluids. Micromachined sensors and interface electronics have been developed to measure temperature, electrical conductivity, pH, cation activity, and anion activity. The Profile Refractometer uses a laser optical system to directly image the fluid Index of Refraction profile that exists along the MTA fluid cell axis. A video system acquires images of the RI profile over time, and records the transport kinetics that occur upon application of chemical, thermal, or electrical driving potentials. Image processing algorithms have been developed to analyze the refractometer images on a pixel by pixel basis, calibrating and scaling the measured Index of Refraction profile to correlated solution properties of interest such as density, concentration, and temperature. Additional software has been developed to compile the processed images into a three dimensional matrix that contains fluid composition data as a function of experiment time and position in the fluid cell. These data are combined with data from the other sensor systems, and analyzed in the context of transport coefficients associated with the various transport phenomena. Analysis protocols have been developed to measure the transient kinetics, and steady state distribution of fluid components that occur in response to the applied driving potentials. The results are expressed in terms of effective transport coefficients. Experiments have been performed using a variety of solutes, and results generated are that are in agreement with published transport coefficient values.

Mason, Larry W.↗

Some General Principles in Cryogenic Design, Implementation, and Testing

Brief Course Description: In 2 hours only the most basic principles of cryogenics can be presented. I will concentrate on the differences between a room temperature thermal analysis and cryogenic thermal analysis, namely temperature dependent properties. I will talk about practical materials for thermal contact and isolation. I will finish by describing the verification process and instrumentation used that is unique to cryogenic (in general less than 100K) systems.

heat transfer↗

BeyondPlanck: XV. Limits on large-scale polarized anomalous microwave emission from Planck LFI and WMAP

We constrained the level of polarized anomalous microwave emission (AME) on large angular scales using Planck Low-Frequency Instrument (LFI) and WMAP polarization data within a Bayesian cosmic microwave background (CMB) analysis framework. We modeled synchrotron emission with a power-law spectral energy distribution, as well as the sum of AME and thermal dust emission through linear regression with the Planck High-Frequency Instrument (HFI) 353 GHz data. This template-based dust emission model allowed us to constrain the level of polarized AME while making minimal assumptions on its frequency dependence. We neglected CMB fluctuations, but show through simulations that these fluctuations have a minor impact on the results. We find that the resulting AME polarization fraction confidence limit is sensitive to the polarized synchrotron spectral index prior. In addition, for prior means β s < -3.1 we find an upper limit of p AME max ≲ 0.6% (95% confidence). In contrast, for means β s = -3.0, we find a nominal detection of p AME = 2.5 ± 1.0% (95% confidence). These data are thus not strong enough to simultaneously and robustly constrain both polarized synchrotron emission and AME, and our main result is therefore a constraint on the AME polarization fraction explicitly as a function of β s . Combining the current Planck and WMAP observations with measurements from high-sensitivity low-frequency experiments such as C-BASS and QUIJOTE will be critical to improve these limits further.

79 ASTRONOMY AND ASTROPHYSICS↗