Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system software”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Grid Stability Awareness System (GSAS) (Final Scientific/Technical Report)

The project team developed a software suite named Grid Stability Awareness System (GSAS) for power system near real-time stability monitoring and analysis based on synchrophasor measurement. The software suite consists of five analytical tools: an oscillation monitoring tool, a voltage stability monitoring tool, a transient instability monitoring tool, an angle difference monitoring tool, and an event detection tool. These tools have been integrated into one framework to provide power grid operators with both real-time or near real-time stability status of a power grid and historical information about system stability status. These tools are being considered for real-time use in the operation environment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experiences Readying Applications for Exascale

The advent of Exascale computing invites an assessment of existing best practices for developing application readiness on the world's largest supercomputers. This work details observations from the last four years in preparing scientific applications to run on the Oak Ridge Leadership Computing Facility's (OLCF) Frontier system. This paper addresses a range of topics in software including programmability, tuning, and portability considerations that are key to moving applications from existing systems to future installations. A set of representative workloads provides case studies for general system and software testing. We evaluate the use of early access systems for development across several generations of hardware. Finally, we discuss how best practices were identified and disseminated to the community through a wide range of activities including user-guides and trainings. We conclude with recommendations for ensuring application readiness on future leadership computing systems.

exascale↗

Experiences readying applications for Exascale

The advent of Exascale computing invites an assessment of existing best practices for developing application readiness on the world's largest supercomputers. This work details observations from the last four years in preparing scientific applications to run on the Oak Ridge Leadership Computing Facility's (OLCF) Frontier system. This paper addresses a range of topics in software including programmability, tuning, and portability considerations that are key to moving applications from existing systems to future installations. A set of representative workloads provides case studies for general system and software testing. We evaluate the use of early access systems for development across several generations of hardware. Finally, we discuss how best practices were identified and disseminated to the community through a wide range of activities including user-guides and trainings. We conclude with recommendations for ensuring application readiness on future leadership computing systems.

Gottiparthi, Kalyan↗

Energy System Modeling with REopt

This poster details how REopt - NREL's software modeling platform for energy systems integration and optimization - can help to model energy systems. Some benefits of modeling with REopt include optimizing behind the meter storage for cost and resiliency, optimizing lab testing, optimizing dispatch of utility scale storage, and quantifying renewable energy impact on outage survivability.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

DEPRECATED Hasty [SWR-20-80]

DEPRECATED This repository was archived by the owner on Nov 18, 2022. It is now read-only. The software is a web app to create semantic metadata models, namely, Haystack and Brick. The purpose of Hasty is to assist in the auditing of building mechanical systems and controls. The software is designed to capture mechanical system topology and important information regarding real world controls implementations. The tool is intended to output Brick / Haystack / ASHRAE 223 compliant models.

Mosiman, Cory↗

Common Cause Failure Evaluation of High Safety Significant Safety-related Digital Instrumentation and Control Systems using IRADIC Technology

Digital instrumentation and control (DI&C) systems in nuclear power plants (NPPs) have many advantages over analog systems but also pose different engineering and technical challenges, such as potential threats due to common cause failures (CCFs). This paper proposes an integrated risk assessment technology for DI&C systems (IRADIC) developed by Idaho National Laboratory for dealing with potential software CCFs in DI&C systems of NPPs. The methodology development of the IRADIC technology on the quantitative evaluation of software CCFs in high safety-significant safety-related DI&C systems in NPPs is illustrated in this paper. In IRADIC, qualitative hazard analysis and quantitative reliability and consequence analysis are successively implemented to obtain quantitative risk information, compare with respective risk evaluation acceptance criteria, and provide suggestions for risk reduction and design optimization. A comprehensive case study was also performed and documented in this paper. Results show that the IRADIC technology can effectively identify potential digital-based CCFs, estimate their failure probabilities, and evaluate their impacts to system and plant safety.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Hybrid Solar GHP Simulator

This project provides an easy-to-use, menu-driven, software tool for designing hybrid solar-geothermal heat pump systems (GHP) for both heating- and cooling-dominated buildings. No such design tool currently exists. In heating-dominated buildings, the design approach takes advantage of glazed solar collectors to effectively balance the annual thermal loads on the ground with renewable solar energy. In cooling-dominated climates, the design approach takes advantage of relatively low-cost, unglazed solar collectors as the heat rejecting component. The primary benefit of hybrid GHPs is the reduced initial cost of the ground heat exchanger (GHX). Furthermore, solar thermal collectors can be used to balance the ground loads over the annual cycle, thus making the GHX fully sustainable; in heating-dominated buildings, the hybrid energy source (i.e., solar) is renewable, in contrast to a typical fossil fuel boiler or electric resistance as the hybrid component; in cooling-dominated buildings, use of unglazed solar collectors as a heat rejecter allows for passive heat rejection, in contrast to a cooling tower that consumes a significant amount of energy to operate, and hybrid GHPs can expand the market by allowing reduced GHX footprint in both heating- and cooling-dominated climates. The design tool allows for the straight-forward design of innovative GHP systems that currently pose a significant design challenge. The project lays the foundations for proper and reliable design of hybrid GHP systems, overcoming a series of difficult and cumbersome steps without the use of a system simulation approach, and without an automated optimization scheme. As new technologies and design concepts emerge, sophisticated design tools and methodologies must accompany them and be made usable for practitioners. Lack of reliable design tools results in reluctance of practitioners to implement more complex systems. A menu-driven software tool for the design of hybrid solar GHP systems is provided that is based on mathematically robust, validated models. An automated optimization tool is used to balance ground loads and incorporated into the simulation engine. With knowledge of the building loads, thermal properties of the ground, the borehole heat exchanger configuration, the heat pump peak hourly and seasonal COP for heating and cooling, the critical heat pump design entering fluid temperature, and the thermal performance of a solar collector, the total GHX length can be calculated along with the area of a supplemental solar collector array and the corresponding reduced GHX length. An economic analysis module allows for the calculation of the lowest capital cost combination of solar collector area and GHX length.

Yavuzturk, Cy↗

Control and Information Systems for the National Ignition Facility

Orchestration of every National Ignition Facility (NIF) shot cycle is managed by the Integrated Computer Control System (ICCS), which uses a scalable software architecture running code on more than 1950 front-end processors, embedded controllers, and supervisory servers. The ICCS operates laser and industrial control hardware containing 66 000 control and monitor points to ensure that all of NIF’s laser beams arrive at the target within 30 ps of each other and are aligned to a pointing accuracy of less than 50 μm root-mean-square, while ensuring that a host of diagnostic instruments record data in a few billionths of a second. NIF’s automated control subsystems are built from a common object-oriented software framework that distributes the software across the computer network and achieves interoperation between different software languages and target architectures. A large suite of business and scientific software tools supports experimental planning, experimental setup, facility configuration, and post-shot analysis. Standard business services using open-source software, commercial workflow tools, and database and messaging technologies have been developed. An information technology infrastructure consisting of servers, network devices, and storage provides the foundation for these systems. Thus, this work is an overview of the control and information systems used to support a wide variety of experiments during the National Ignition Campaign.

42 ENGINEERING↗

Direct FuelCell/Turbine Power Plant

This report summarizes the progress made in development of Direct FuelCell/Turbine (DFC/T{reg_sign}) power plants for generation of clean power at very high efficiencies. The DFC/T system employs an indirectly heated Turbine Generator to supplement fuel cell generated power. The concept extends the high efficiency of the fuel cell by utilizing the fuel cell's byproduct heat in a Brayton cycle. Features of the DFC/T system include: electrical efficiencies of up to 75% on natural gas, minimal emissions, reduced carbon dioxide release to the environment, simplicity in design, direct reforming internal to the fuel cell, and potential cost competitiveness with existing combined cycle power plants. Proof-of-concept tests using a sub-MW-class DFC/T power plant at FuelCell Energy's (FCE) Danbury facility were conducted to validate the feasibility of the concept and to measure its potential for electric power production. A 400 kW-class power plant test facility was designed and retrofitted to conduct the tests. The initial series of tests involved integration of a full-size (250 kW) Direct FuelCell stack with a 30 kW Capstone microturbine. The operational aspects of the hybrid system in relation to the integration of the microturbine with the fuel cell, process flow and thermal balances, and control strategies for power cycling of the system, were investigated. A subsequent series of tests included operation of the sub-MW Direct FuelCell/Turbine power plant with a Capstone C60 microturbine. The C60 microturbine extended the range of operation of the hybrid power plant to higher current densities (higher power) than achieved in initial tests using the 30kW microturbine. The proof-of-concept test results confirmed the stability and controllability of operating a fullsize (250 kW) fuel cell stack in combination with a microturbine. Thermal management of the system was confirmed and power plant operation, using the microturbine as the only source of fresh air supply to the system, was demonstrated. System analyses of 40 MW DFC/T hybrid systems, approaching 75% efficiency on natural gas, were carried out using CHEMCAD simulation software. The analyses included systems for near-term and long-term deployment. A new concept was developed that was based on clusters of one-MW fuel cell modules as the building blocks. The preliminary design of a 40 MW power plant, including the key equipment layout and the site plan, was completed. The process information and operational data from the proof-of-concept tests were used in the design of 40 MW high efficiency DFC/T power plants. A preliminary cost estimate for the 40 MW DFC/T plant was also prepared. Pilot-scale tests of the cascaded fuel cell concept for achieving high fuel utilizations were conducted. The tests demonstrated that the concept has the potential to offer higher power plant efficiency. Alternate stack flow geometries for increased power output and fuel utilization capabilities were also evaluated. Detailed design of the packaged sub-MW DFC/T Alpha Unit was completed, including equipment and piping layouts, instrumentation, electrical, and structural drawings. The lessons learned from the proof-of-concept tests were incorporated in the design of the Alpha Unit. The sub-MW packaged unit was fabricated, including integration of the Direct FuelCell{reg_sign} (DFC{reg_sign}) stack module with the mechanical balance-of-plant and electrical balance-of-plant. Factory acceptance tests of the Alpha DFC/T power plant were conducted at Danbury, CT. The Alpha Unit achieved an unsurpassed electrical efficiency of 58% (LHV natural gas) during the factory tests. The resulting high efficiency in conversion of chemical energy to electricity far exceeded any sub-MW class power generation equipment presently in the market. After successful completion of the factory tests, the unit was shipped to the Billings Clinic in Billings, MT, for field demonstration tests. The DFC/T unit accomplished a major achievement by successfully completing 8000 hours of operation at the Billings site. The Alpha sub-MW DFC/T power plant unit was returned to the factory for post-operation inspection and analysis. The success of the Alpha Unit operation in the field and achievement of the ultra-high efficiency of 58%, triggered the establishment of a MW-scale commercial product design and development program. Design of a 3 MW (nominal rating) DFC/T Power Plant was completed with an electrical efficiency approaching 60+% LHV of natural gas depending on the design and performance of the gas turbine. Development efforts incorporated lessons learned from the Alpha sub-MW DFC/T power plant demonstration, as well as design features from FCE's commercial product offerings, the DFC1500 and DFC3000 MW-class simple cycle power plants. The 3 MW DFC/T power plant is anticipated to be a superb alternative for large distributed generation applications in locations with high cost-of-electricity.

03 NATURAL GAS↗

Automated metadata, provenance cataloging and navigable interfaces: ensuring the usefulness of extreme-scale data

The MPO (Metadata, Provenance, Ontology) Project successfully addressed the goal of improving the usefulness and traceability of scientific data by building a system that could capture and display all steps in the process of creating, analyzing and disseminating that data. Throughout history, scientists have generated handwritten logbooks to keep track of data, their hypotheses, assumptions, experimental setup, and computational processes as well as reflections on observations and issues encountered. Over the last several decades, with the growth of personal computers, handheld devices, and the World Wide Web, the handwritten logbook has begun to be replaced by electronic logbooks. This transition has brought increased capability such as supporting multi-media, hypertext, and fast searching. However, content creation and metadata (a set of data that describes and gives information about other data) capturing has for the most part remained a manual activity just as it was with handwritten logbooks. This has led to a fragmentation of data, processing, and annotation that has only accelerated as scientific workflows continue to increase in complexity. From a scientific perspective, it is very important to be able to understand the lineage of any piece of data: who, what, when, how, and why. This is typically referred to as data provenance. The fragmentation discussed previously often means that data provenance is lost. As scientific workflows move to powerful computers and become more complex, the ability to track all of the steps involved in creating a piece of data become even more difficult. It was the goal of the MPO (Metadata, Provenance, Ontology) Project to create a system (the MPO System) that allows for automatic provenance and metadata capturing in such a way to allow easy searching and browsing. This goal needed to be accomplished in a general way so that it may be used across a broad range of scientific domains, yet allow the addition of vocabulary (Ontology) that is domain specific as is required for intelligent searching and browsing in the scientific context. Through the creation and deployment of the MPO system, the goals of the project were achieved. An enhanced metadata, provenance, and ontology storage system was created. This was combined with innovative methodologies for navigating and exploring these data using a web browser for both experimental and simulation-based scientific research. In addition, a system to allow scientists to instrument their existing workflows for automatic metadata and provenance is part of the MPO system. In that way, a scientist can continue to use their existing methodology yet easily document their work. Workflows and data provenance can be displayed either graphically or in an electronic notebook format and support advanced search features including via ontology. The MPO system was successfully used in both Climate and Magnetic Fusion Energy Research. The software for the MPO system is located at https://github.com/MPO-Group/MPO and is open source distributed under the Revised BSD License. A demonstration site of the MPO system is open to the public and is available at https://mpo.psfc.mit.edu/. A Docker container release of the command line client is available for public download using the command docker pull jcwright/mpo-cli at https://hub.docker.com/r/jcwright/mpo-cli.

97 MATHEMATICS AND COMPUTING↗

Scalable PETSc Implementation of the Three-Phase Unbalanced AC Power Flow Solver

A revolutionary transition of energy infrastructure, spanning across supply and demand sectors, is happening all around the world. Integration of renewable energy sources into our ever-complex power distribution networks is central to the infrastructure planning of the future. One step towards achieving this goal is to solve unbalanced transmission and distribution systems. Traditional approaches and software tools are not suitable because they assume a completely balanced 3-phase system, hence a single-phase equivalent can be solved. Renewable energy such as wind and solar power are intermittent and can pose a challenge when integrating into an already unbalanced power grid. Furthermore, these power grids can be quite large at scale consisting of potentially thousands of buses, which can be computationally demanding. This poster presents preliminary work on designing a robust and scalable 3-phase unbalanced AC power flow solver. The proposed power flow solver will eventually be built on top of the PETSc library and utilizes state-of-the-art parallel data structures like the DMNetwork as well as iterative solvers and preconditioners.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cooperation on Improved Isotopic Identification and Analysis Software for Portable, Electrically Cooled High-Resolution Gamma Spectrometry Systems Final Report

Under a 2006 agreement between the Department of Energy (DOE) of the United States of America and the Institut de Radioprotection et de Sûreté Nucléaire (IRSN) of France, the National Nuclear Security Administration (NNSA) within DOE and IRSN initiated a collaboration to improve isotopic identification and analysis of nuclear material [i.e., plutonium (Pu) and uranium (U)]. The specific aim of the collaborative project was to develop new versions of two types of isotopic identification and analysis software: (1) the fixed-energy response-function analysis for multiple energies (FRAM) codes and (2) multi-group analysis (MGA) codes. The project is entitled Action Sheet 4 – Cooperation on Improved Isotopic Identification and Analysis Software for Portable, Electrically Cooled, High-Resolution Gamma Spectrometry Systems (Action Sheet 4). FRAM and MGA/U235HI are software codes used to analyze isotopic ratios of U and Pu. FRAM is an application that uses parameter sets for the analysis of U or Pu. MGA and U235HI are two separate applications that analyze Pu or U, respectively. They have traditionally been used by safeguards practitioners to analyze gamma spectra acquired with high-resolution gamma spectrometry (HRGS) systems that are cooled by liquid nitrogen. However, it was discovered that these analysis programs were not as accurate when used on spectra acquired with a newer generation of more portable, electrically cooled HRGS (ECHRGS) systems. In response to this need, DOE/NNSA and IRSN collaborated to update the FRAM and U235HI codes to improve their performance with newer ECHRGS systems. Lawrence Livermore National Laboratory (LLNL) and Los Alamos National Laboratory (LANL) performed this work for DOE/NNSA.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A software framework for assessing the resilience of drinking water systems to disasters with an example earthquake case study

Water utilities are vulnerable to a wide variety of human-caused and natural disasters. The Water Network Tool for Resilience (WNTR) is a new open source PythonTM package designed to help water utilities investigate resilience of water distribution systems to hazards and evaluate resilience-enhancing actions. In this paper, the WNTR modeling framework is presented and a case study is described that uses WNTR to simulate the effects of an earthquake on a water distribution system. The case study illustrates that the severity of damage is not only a function of system integrity and earthquake magnitude, but also of the available resources and repair strategies used to return the system to normal operating conditions. While earthquakes are particularly concerning since buried water distribution pipelines are highly susceptible to damage, the software framework can be applied to other types of hazards, including power outages and contamination incidents.

97 MATHEMATICS AND COMPUTING↗

Verification Data Pattern Recognition and Change Detection at the Neutron Instrument Level

As the pressure on International Atomic Energy Agency (IAEA) safeguards resources increases, there is a drive to essentially “do more with less.” New ways of using current verification instrumentation and visualizing the collected data are needed, coupled with maintaining and sustaining the current safeguards instrumentation fleet. This paper explores how to innovate with current safeguards neutron instrumentation using data-driven algorithms at the instrument level. A concept is described for upgrading current neutron counting systems with modern electronics by leveraging electronics developments in other fields (e.g., high-energy physics) to facilitate full list mode data acquisition and, therefore, expand existing analyses to pattern recognition and change detection at the instrument level. The aim is to advance correlated neutron counting by improving the reliability of detecting nuclear material diversion and, at the same time, to improve the sustainability of those systems. It is likely that upgrading existing systems with new hardware and software is more cost-effective than replacing systems with other novel systems that might meet this need. A specific project example is highlighted in which a system was upgraded by retrofitting the standard uranium neutron collar detector with new electronics; as a result, verification data can be analyzed in new ways. A new neutron analysis method, the “List Mode Response Matrix,” has been developed to analyze every pulse train from the detector array and thus enable the verification of spatial information about the assay item for safeguards inspections. This project has improved the reliability of resolving individual fuel pin locations within a given fresh fuel assembly and the percentage of partial defects detected. Herein, the overall concept of upgrading current neutron counting systems is discussed with respect to the potential increase in analysis capabilities. In addition, the details and results of the list mode collar project are discussed.

Worrall, Louise G.↗

Advanced Simulation and Computing (ASC) Software Quality Plan: ASC Software Quality Engineering Practices (V.4.0)

The purpose of the Sandia National Laboratories (SNL) Advanced Simulation and Computing (ASC) Software Quality Plan is to clearly identify the software quality engineering practices that are the basis for continually improving the quality of ASC software products. This plan defines the SNL ASC Program software quality engineering practices and provides a mapping of these practices to Laboratory Policy System IT008: Provide Quality Software Policy. This plan also identifies ASC Program Management and the software project teams' responsibilities in implementing quality software engineering practices and in assessing progress towards achieving their software quality goals.

97 MATHEMATICS AND COMPUTING↗

NDA Tech: Multimodal Data Fusion with 3D Gamma-Ray Imaging for Safeguards

The ultimate project goal is to improve quantitative results obtained by the IAEA with the H420 gamma ray imager. Distribution to the IAEA will be through incorporation of project results into the software provided with the device by our commercial partner, H3D, Inc. Toward achieving that goal, we have started discussions with H3D to identify the requisite software components and how they will mesh with their own internally developed contextual data systems and other extant software components. We have identified the coded-aperture response data cube as a key structure. Discussions on contextual imaging were informative but somewhat inconclusive as the project lead on contextual data (LBNL) has not been available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wire Scanner Beam Profile Measurements for the LANSCE Facility

The Los Alamos Neutron Science Center (LANSCE) is replacing beam profile measurement systems, commonly known as Wire Scanners (WS). Using the principal of secondary electron emission, the WS measurement system moves a wire or fiber across an impinging particle beam, sampling a projected transverse-beam distribution. Because existing WS actuators and electronic components are either no longer manufactured or home-built with antiquated parts, a new WS beam profile measurement is being designed, fabricated, and tested. The goals for these new WS's include using off-the-shelf components while eliminating antiquated components, providing quick operation while allowing for easy maintainability, and tolerating external radioactivation. The WS measurement system consists of beam line actuators, a cable plant, an electronics processor chassis, and software located both in the electronics chassis (National Instruments LabVIEW) and in the Central Control Room (EPICS-based client software). This WS measurement system will measure Hand H{sup +} LANSCE-facility beams and will also measure less common beams. This paper describes these WS measurement systems.

43 PARTICLE ACCELERATORS↗

Special Issue on Data-Intensive Scalable Computing Systems

Traditional high performance computing (HPC) systems were designed from a compute-centric perspective, with an emphasis on high floating point performance. As scientific and analytics applications become more data intensive, there is a need to rethink HPC system architectures, programming models, runtime systems, and tools with a focus on scalable data intensive computing. Industry approaches supporting data intensive applications have been highly successful, leading many in the HPC community to search for ways to adapt them to HPC hardware and software contexts. Conversely, industry looks to the HPC community for their expertise in designing, deploying, and using extremely large and high performance computing systems. This special issue contains seven articles, each of which is an extended version of a paper presented in the 2015 International Workshop on Data Intensive Scalable Computing Systems (DISCS-2015) held in Austin, Texas on November 15, 2015. The workshop program included papers that ranged from programming models to systems software to storage, each with a strong focus on data intensive computing.

97 MATHEMATICS AND COMPUTING↗