Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “soft”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Mobility Selective Ion Soft-Landing and Characterization Enabled Using Structures for Lossless Ion Manipulation

In this study, while conventional ion-soft landing uses the mass-to-charge (m/z) ratio to achieve molecular selection for deposition, here we demonstrate the use of Structures for Lossless Ion Manipulation (SLIM) for mobility-based ion selection and deposition. The dynamic rerouting capabilities of SLIM were leveraged to enable the rerouting of a selected range of mobilities to a different SLIM path (rather than MS) that terminated at a deposition surface. A selected mobility range from a phosphazene ion mixture was rerouted and deposited with a current pulse (~150 pA) resembling its mobility peak. In addition, from a mixture of tetra-alkyl ammonium (TAA) ions containing chain lengths of C5–C8, selected chains (C6, C7) were collected on a surface, reconstituted into solution-phase, and subsequently analyzed with a SLIM-qToF to obtain an IMS/MS spectrum, confirming the identity of the selected species. Further, this method was used to characterize triply charged tungsten-polyoxometalate anions, PW 12 O 40 3– (WPOM). The arrival time distribution of the IMS/MS showed multiple peaks associated with the triply charged anion (PW 12 O 40 3– ), of which a selected ATD was deposited and imaged using TEM. Additionally, the identity of the deposited WPOM was ascertained using energy-dispersive (EDS) spectroscopy. Further, we present theory and computations that reveal ion landing energies, the ability to modulate the energies, and deposition spot sizes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Navigating the Expansive Landscapes of Soft Materials: A User Guide for High-Throughput Workflows

Synthetic polymers are highly customizable with tailored structures and functionality, yet this versatility generates challenges in the design of advanced materials due to the size and complexity of the design space. Thus, exploration and optimization of polymer properties using combinatorial libraries has become increasingly common, which requires careful selection of synthetic strategies, characterization techniques, and rapid processing workflows to obtain fundamental principles from these large data sets. Herein, we provide guidelines for strategic design of macromolecule libraries and workflows to efficiently navigate these high-dimensional design spaces. We describe synthetic methods for multiple library sizes and structures as well as characterization methods to rapidly generate data sets, including tools that can be adapted from biological workflows. We further highlight relevant insights from statistics and machine learning to aid in data featurization, representation, and analysis. This Perspective acts as a “user guide” for researchers interested in leveraging high-throughput screening toward the design of multifunctional polymers and predictive modeling of structure–property relationships in soft materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Soft X-ray Spectroscopy Study of the Electronic Structure of Oxidized and Partially Oxidized Magnetite Nanoparticles

The crystal structure of magnetite nanoparticles may be transformed to maghemite by complete oxidation, but under many relevant conditions the oxidation is partial, creating a mixed-valence material with structural and electronic properties that are poorly characterized. We used X-ray diffraction, Fe K-edge extended X-ray absorption fine structure (EXAFS) spectroscopy, and soft X-ray absorption and emission spectroscopy to characterize the products of oxidizing uncoated and oleic acid-coated magnetite nanoparticles in air. The oxidization of uncoated magnetite nanoparticles creates a material that is structurally and electronically indistinguishable from maghemite. By contrast, while oxidized oleic acid-coated nanoparticles are also structurally indistinguishable from maghemite, Fe L-edge spectroscopy revealed the presence of interior reduced iron sites even after a 2-year period. We used X-ray emission spectroscopy at the O K-edge to study the valence bands (VB) of the iron oxide nanoparticles, using resonant excitation to remove the contributions from oxygen atoms in the ligands and from low-energy excitations that obscured the VB edge. The bonding in all nanoparticles was typical of maghemite, with no detectable VB states introduced by the long-lived, reduced-iron sites in the oleic acid-coated sample. However, O K-edge absorption spectroscopy observed a 0.2 eV shift in the position of the lowest unoccupied states in the coated sample, indicating an increase in the semiconductor band gap relative to bulk stoichiometric maghemite that was also observed by optical absorption spectroscopy. The results show that the ferrous iron sites within ferric iron oxide nanoparticles coated by an organic ligand can persist under ambient conditions with no evidence of a distinct interior phase and can exert an effect on the global electronic and optical properties of the material. This phenomenon resembles the band gap enlargement caused by electron accumulation in the conduction band of TiO2.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Soft-Landing of CoIII(salen)+ and MnIII(salen)+ on Self-Assembled Monolayer Surfaces

Soft-landing of mass-selected CoIII(salen)+ and MnIII(salen)+ complexes was performed using self-assembled monolayer surfaces of alkanethiol (HSAM) and fluorinated alkanethiol (FSAM) on gold as targets. Physical processes associated with ion deposition were studied using time-resolved in situ secondary ion mass spectrometry (SIMS) in a specially designed Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS). We demonstrate charge retention by a significant fraction of precursor ions on the FSAM and complete neutralization on the HSAM surface. Our results indicate efficient electron transfer from gold to the deposited species for the HSAM surface and inefficient, if any, electron transfer on the FSAM surface. Formation of abundant cluster ions observed in SIMS spectra is attributed to gas-phase reactions in the SIMS plume. Detailed analysis allowed us to extract the kinetics of both ionic and neutral complexes trapped on the FSAM surface. The results indicate that neutralization on this surface most likely takes place on the defect sites.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Theory-driven design of high-valence metal sites for water oxidation confirmed using in situ soft X-ray absorption

The efficiency with which renewable fuels and feedstocks are synthesized from electrical sources is limited at present by the sluggish oxygen evolution reaction (OER) in pH-neutral media. Here, we took the view that generating transition metal sites with high valence at low applied bias should improve the activity of neutral OER catalysts. Using density functional theory, we find that the formation energy of desired Ni 4+ sites is systematically modulated by incorporating judicious combinations of Co, Fe and non-metal phosphorus. Here we synthesized NiCoFeP oxyhydroxides and probed their oxidation kinetics by employing in situ soft X-ray absorption (sXAS). In situ sXAS studies of neutral-pH OER catalysts indicate ready promotion of Ni 4+ under low overpotential conditions. NiCoFeP catalyst outperforms IrO 2 and retains its performance following 100 hours of operation. We showcase NiCoFeP in a membrane-free CO 2 electroreduction system that achieves a 1.99 V cell voltage at 10 mA cm -2 , reducing CO 2 into CO and oxidizing H 2 O to O 2 with a 64% electricity-to-chemical-fuel efficiency.

30 DIRECT ENERGY CONVERSION↗

High-resolution neutron spectroscopy using backscattering and neutron spin-echo spectrometers in soft and hard condensed matter

The instruments best suited to performing high-energy-resolution neutron spectroscopy are spin-echo spectrometers and backscattering spectrometers. The development of these experimental techniques dates back almost half a century, and most major neutron scattering facilities operate mature spectrometers of one or both classes. Recent advances in instrumentation and neutron sources are enhancing their performance and expanding their capabilities, with the objective of enabling researchers to tackle new and more complex problems. Finally, in this Technical Review, we assess the current state of the art in high-energy-resolution neutron spectrometers, showcasing their role in the study of nanoscale dynamics in soft and biological materials, as well as disordered magnets.

47 OTHER INSTRUMENTATION↗

Hard-to-soft transition-enhanced piezoelectricity in poly(vinylidene fluoride) via relaxor-like secondary crystals activated by high-power ultrasonication

We report although high piezoelectric coefficients have recently been observed in poly(vinylidene fluoride-co-trifluoroethylene) [P(VDF-TrFE)] random copolymers, they have low Curie temperatures, which makes their piezoelectricity thermally unstable. It has been challenging to achieve high piezoelectric performance from the more thermally stable PVDF homopolymer. In this report, we describe how high-power ultrasonic processing was used to induce a hard-to-soft piezoelectric transition and improve the piezoelectric coefficient d 31 in neat PVDF. After high-power ultrasonication for 20 min, a uniaxially stretched and poled PVDF film exhibited a high d 31 of 50.2 ± 1.7 pm V -1 at room temperature. Upon heating to 65 °C, the d 31 increased to a maximum value of 76.2 ± 1.2 pm V -1 , and the high piezoelectric performance persisted up to 110 °C. The enhanced piezoelectricity was attributed to the relaxor-like secondary crystals in the oriented amorphous fraction, broken off from the primary crystals by ultrasonication, as suggested by differential scanning calorimetry and broadband dielectric spectroscopy studies.

relaxor-like secondary crystals↗

Synchrotron Soft X-ray Studies of Single-Walled Carbon Nanotubes Functionalized by Radio-Frequency SF{sub 6} Plasma

Single-walled carbon nanotubes have been functionalized using an inductively coupled radio-frequency plasma system with SF{sub 6}, O{sub 2} and H{sub 2}O plasmas. Samples were characterized using synchrotron soft X-ray photoemission spectroscopy. The influence of plasma power has been investigated along with the effect of gaseous mixtures. It has been found that oxygen has a strong influence over the extent of fluorination both as an impurity in the SF{sub 6} plasma and in the form of surface oxygen content on the nanotubes prior to exposure. The presence of sulfur in samples after exposure has until now been considered non-existent but using the synchrotron source, its presence has been noted in very small concentrations.

36 MATERIALS SCIENCE↗

Ferrimagnetism in epitaxially grown Mn{sub 2}VAl Heusler alloy investigated by means of soft x-ray magnetic circular dichroism

Epitaxially grown Mn{sub 2}VAl films were fabricated on MgO (001) single crystalline substrates by using a sputtering technique. The resulting Mn{sub 2}VAl films with substrate temperatures of T{sub s}=500 and 600 deg. C showed an L2{sub 1}-ordered structure. The saturation magnetization was 150 emu/cm{sup 3} at 300 K for a sample with T{sub s}=600 deg. C. Ferrimagnetic coupling between the Mn and V magnetic moments in the L2{sub 1}-Mn{sub 2}VAl film was clearly demonstrated by soft x-ray magnetic circular dichroism. In previous studies, this coupling was found only in polycrystalline bulk samples examined by nuclear magnetic resonance.

36 MATERIALS SCIENCE↗

Highly efficient pulsed power supply system with a two-stage LC generator and a step-up transformer for fast capillary discharge soft x-ray laser at shorter wavelength

Highly efficient and compact pulsed power supply system for a capillary discharge soft x-ray laser (SXRL) has been developed. The system consists of a 2.2 {mu}F two-stage LC inversion generator, a 2:54 step-up transformer, a 3 nF water capacitor, and a discharge section with a few tens of centimeter length capillary. Adoption of the pulsed transformer in combination with the LC inversion generator enables us to use only one gap switch in the circuit for charging the water capacitor up to about 0.5 MV. Furthermore, step-up ratio of a water capacitor voltage to a LC inversion generator initial charging voltage is about 40 with energy transfer efficiency of about 50%. It also leads to good reproducibility of a capillary discharge which is necessary for lasing a SXRL stably. For the study of the possibility of lasing a SXRL at shorter wavelength in a small laboratory scale, high-density and high-temperature plasma column suitable for the laser can be generated relatively easily with this system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Longitudinal and transverse magnetization components in thin films: A resonant magnetic reflectivity investifation using circularly polarized soft x-rays

An in-plane vectorial analysis of the magnetization of thin magnetic films is presented. Longitudinal soft x-ray resonant magnetic reflectivity curves display characteristic nodes where the longitudinal scattering component is suppressed by x-ray interference. The transverse magnetic component can be effectively retrieved at these nodal points, despite the use of circular polarization and longitudinal scattering geometry. Using a single geometric configuration, transverse and longitudinal magnetic hysteresis loops can be clearly separated. Calculations based on a Stoner-Wohlfarth model satisfactorily describe both loops. Therefore, this method presents a viable alternative to standard vectorial analysis techniques, with the additional benefit of element specificity.

36 MATERIALS SCIENCE↗

Soft X-Ray Spectrometer Using 100-Pixel STJ Detectors for Synchrotron Radiation

Fluorescent X-ray absorption fine structure (XAFS) is an important tool for material analysis, especially for the measurement of chemical states or local structures of elements. Semiconductor detectors are usually used for separating the fluorescent of elements in question from background fluorescence. However, the semiconductor detectors cannot always discriminate K-lines of light elements and L-lines of various elements as different X-ray peaks at an energy range below about 3 keV. Superconducting tunnel junction (STJ) detectors are promising device for the soft X-ray at synchrotron radiation beam lines because of excellent energy resolution, high detection efficiency, and high counting rate. We are constructing a fluorescent X-ray spectrometer having 100-pixel array of STJs with 200 {mu}m square. The array detector is mounted on a liquid cryogen-free {sup 3}He cryostat. The sensitive area is the largest among the superconducting X-ray spectrometers operating at synchrotron beam lines. Each pixel is connected to a room temperature readout circuit that consists of a charge sensitive amplifier and a pulse height analyzer. The spectrometer will achieve a total solid angle of {approx}0.01 sr and a maximum counting rate of more than 1 M count per second. The present status of developments of our fluorescent X-ray spectrometer was reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental Results and Modeling of Low-Heat-Capacity TES Microcalorimeters for Soft-X-ray Spectroscopy

Transition-edge-sensor (TES) X-ray microcalorimeters have mostly been targeted at mid-band energies from 0.05-10 keV and high energies to above 100 keV. However, many other optimizations are possible. Here we present results from devices optimized for soft X-ray applications. For spectroscopy below 1 keV, the X-ray stopping power and heat capacity (C) of the TES itself are high enough that we can omit a separate absorber. The resulting devices have low C and the best-achievable energy resolution should be under 1 eV. We are interested in pursuing such devices primarily for astrophysical applications and laboratory astrophysics at LLNL's Electron-Beam Ion Trap. To this end, we have studied arrays in which 'bare' TESs are interspersed with broad-band pixels that have absorbers. By extending the absorbers to cover the area where the leads contact the low-energy pixels, we have eliminated a significant source of non-Gaussian detector response. The bare devices are in a different regime from our typical devices in that C is ten times lower and the conductance to the bath is four times lower. We have explored this regime through simultaneous fitting of noise and impedance data. These data cannot be fit by the simple model we employ to describe our typical broad-band devices. In this contribution we present X-ray spectra and the results from modeling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Astro-H Soft X-ray Spectrometer (SXS)

The Soft-X-ray Spectrometer (SXS) is a high spectral resolution, cryogenic x-ray spectrometer that will fly on the Japan/U.S. Astro-H observatory in 2014. The SXS is composed of a 36 pixel, imaging, x-ray calorimeter array that will operate at 0.05 K utilizing a 2-stage adiabatic demagnetization refrigerator and a redundant pre-cooler design using both a 40 liter liquid helium tank and a 1.7 K Joule-Thomson (JT) cryocooler. Additional redundant Stirling cycle coolers provide pre-cooling for the (JT) and cool the outer thermal shields for the JT and the helium tank. The detector system, while similar to that flown on Suzaku, is composed of larger 0.81x0.81mm pixels, but has significantly better performance, currently predicted to be better than 4 eV FWHM at 6 keV with 95% quantum efficiency. This instrument is the result of a close collaboration between many institutions in the U.S. and Japan over the last 25 years. Here we will present an overview of the SXS instrument, the SXS cooling system, and recent laboratory improvements to the detector system.0.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Response-time improved hydrothermal-method-grown ZnO scintillator for soft x-ray free-electron laser timing-observation

For pump and probe experiments in x-ray free-electron laser (XFEL) facilities, accurate timing synchronization between short-wavelength femtosecond pulses from XFELs and short optical pulses from other light sources is required. For this purpose, the response time of a hydrothermal-method-grown ZnO is improved by over one order of magnitude via intentional iron ion doping. The fluorescence rise- and decay-time constants are measured to be less than 10 and 100 ps, respectively. Owing to its intense fluorescence even for single pulse XFEL excitation, the timing jitter of the soft x-ray pulse and timing electronics are evaluated to be less than 70 ps.

43 PARTICLE ACCELERATORS↗

Phase-Contrast Imaging of Nanostructures with Incoherent Femtosecond Laser Driven Soft X-Ray Source

Application of polychromatic (1.5-15 nm) soft X-ray emission of a spatially large (>0.1 mm) bright femtosecond laser driven plasma source for propagation based phase contrast imaging of nanometer thick foils and biological samples is considered. Diffraction and phase contrast effects increased quality and contrast of the experimental images, registered by LiF crystal X-ray detector with submicron resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

OPTIMIZATION OF A TWO-STAGE ADR FOR THE SOFT X-RAY SPECTROMETER (SXS) INSTRUMENT ON THE ASTRO-H MISSION

NASA/Goddard Space Flight Center has begun developing the Soft X-ray Spectrometer (SXS) instrument that will be flown on the Japanese Astro-H mission. The SXS's 36-pixel detector array will be cooled to 50 mK using a two-stage adiabatic demagnetization refrigerator (ADR). A complicating factor for its design is that the ADR will be integrated into a superfluid helium dewar at 1.3 K that will be coupled to a 1.8 K Joule-Thomson (JT) stage through a heat switch. When liquid helium is present, the coupling will be weak, and the JT stage will act primarily as a shield to reduce parasitic heat loads. When the liquid is depleted, the heat switch will couple more strongly so that the ADR can continue to operate using the JT stage as its heat sink. A two-stage ADR is the most mass efficient option and it has the operational flexibility to work well with a stored cryogen and a cryocooler. The stages are operated independently, and this opens up a very large parameter space for optimizing the design. This paper discusses the optimization process and most relevant trades considered in the design of the SXS ADR, and its expected performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact, sample-in-atmospheric-pressure soft x-ray microscope developed at Pohang Light Source

A full-field transmission soft x-ray microscope (TXM) was developed at the Pohang Light Source. With a 2 mm diameter condenser zone plate and a 40 nm outermost-zone-width objective zone plate, the TXM's achieved spatial resolution is better than 50 nm at the photon energy of 500 eV (wavelength: 2.49 nm). The TXM is portable and mounted in tandem with a 7B1 spectroscopy end station. The sample position is outside the vacuum, allowing for quick sample changes and enhanced in situ experimental capability. In addition, the TXM is pinhole-free and easy to align, having commercial mounts located outside the vacuum components.

43 PARTICLE ACCELERATORS↗