Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Improving Thermal Management Strategies for Data Centers: A Physical Testbed Incorporating Small Modular Reactor and Microreactor Technology

This study aims to accelerate the demonstration of various thermal management systems for data centers using nuclear-generated heat to enhance energy and grid reliability. Utilizing mobile containerized and stationary test beds at INL's High Performance Computing (HPC) facility, this project integrates with various nuclear-related energy systems testing facilities. Key components include immersion cooling apparatus, absorption chillers, and adjustable thermal management simulators. Tasks involve acquiring necessary hardware, sensors, and cooling apparatus, engaging with data center industry stakeholders, and providing a testing platform for algorithms, models, tools, and software. The objective is to expedite the deployment of nuclear-powered data centers, thereby improving energy reliability and affordability.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Development of Bismuth and Platinum Bi-Metallic Nanoparticles to Enhance Melt Wire Temperature Resolution

Advanced manufacturing (AM) based on direct-write (DW) technologies has emerged as the predominant enabler for the fabrication of active and passive sensors to be deployed in harsh operating environments seen in a nuclear reactor. Recently, Idaho National Laboratory and Boise State University have recently established capabilities to incorporate advanced manufacturing (AM) methods to accelerate, modernize and enhance functionality of nuclear sensors and instrumentation to achieve the goal of enhancing the safety and efficiency of nuclear reactors. A significant thrust of this work includes the development of nuclear relevant feedstock materials compatible with a variety of direct-write processes for the development, fabrication and testing of AM sensors for peak temperature detection and neutron flux monitoring. For this report, bismuth and bismuth/platinum (BiPt) bi-metallic nanoparticles were synthesized using wet chemical approaches to develop bi-metallic feedstock materials to enhance the sensitivity of melt wires for peak temperature detection. Nanoparticle characterization was performed with Transmission Electron Microscopy (TEM) for nanoparticle composition and size, Transmission X-Ray Diffraction Fluorescence (TXRF) for nanoparticle composition, and Differential Scanning Calorimetry to elucidate the melting point of BiPt bi-metallic nanoparticles. Preliminary results indicate bi-metallic BiPt nanoparticles as a viable pathway for fabricating high resolution AM melt wires.

36 MATERIALS SCIENCE↗

Tools Assessing Performance (FY2022 Quarter 4 Report)

We were finally successful in acquiring TTU’s 200-meter tower data for the duration of the Isolated Building Wake Experiment (IBWE). This data will provide an independent measurement of the undisturbed wind profile including heights far above those that are typical of meteorological sensor networks. These measurements will characterize the mean and turbulence throughout the atmospheric surface layer, which will be particularly useful for validation of highfidelity computational fluid dynamics models. This dataset can be shared freely among the TAP team but not outside of it as TTU sells this data to the wind power industry. The journal article overview has been submitted to LANL’s publication review and will be submitted to the Journal of Wind Engineering and Industrial Aerodynamics once the review is complete. We are nearing completion on another two articles. The first discusses analyses of the evolution of the measurements of mean wind speed along the centerline of the building as a function of atmospheric stability. Rather than using individual time steps, all of the wind speed measurements are normalized using the upwind measurement at 2 building heights (H) and filtered by wind direction and atmospheric stability. The second discusses the development of the diffusive wake model and uses the averaged profiles from the first article to validate the behavior of the model. The portion of the section below on the diffusive wake model discussing comparisons with the averaged profiles, will be included in the validation section of this paper.

17 WIND ENERGY↗

The Concept of a Quantum Edge Simulator: Edge Computing and Sensing in the Quantum Era

Sensors, enabling observations across vast spatial, spectral, and temporal scales, are major data generators for information technology (IT). Processing, storing, and communicating this ever-growing amount of data pose challenges for the current IT infrastructure. Edge computing—an emerging paradigm to overcome the shortcomings of cloud-based computing—could address these challenges. Furthermore, emerging technologies such as quantum computing, quantum sensing, and quantum communications have the potential to fill the performance gaps left by their classical counterparts. Here, we present the concept of an edge quantum computing (EQC) simulator—a platform for designing the next generation of edge computing applications. An EQC simulator is envisioned to integrate elements from both quantum technologies and edge computing to allow studies of quantum edge applications. The presented concept is motivated by the increasing demand for more sensitive and precise sensors that can operate faster at lower power consumption, generating both larger and denser datasets. These demands may be fulfilled with edge quantum sensor networks. Envisioning the EQC era, we present our view on how such a scenario may be amenable to quantification and design. Given the cost and complexity of quantum systems, constructing physical prototypes to explore design and optimization spaces is not sustainable, necessitating EQC infrastructure and component simulators to aid in co-design. We discuss what such a simulator may entail and possible use cases that invoke quantum computing at the edge integrated with new sensor infrastructures.

47 OTHER INSTRUMENTATION↗

Anomaly Detection in Liquid Sodium Cold Trap Operation with Multisensory Data Fusion Using Long Short-Term Memory Autoencoder

Sodium-cooled fast reactors (SFR), which use high temperature fluid near ambient pressure as coolant, are one of the most promising types of GEN IV reactors. One of the unique challenges of SFR operation is purification of high temperature liquid sodium with a cold trap to prevent corrosion and obstructing small orifices. We have developed a deep learning long short-term memory (LSTM) autoencoder for continuous monitoring of a cold trap and detection of operational anomaly. Transient data were obtained from the Mechanisms Engineering Test Loop (METL) liquid sodium facility at Argonne National Laboratory. The cold trap purification at METL is monitored with 31 variables, which are sensors measuring fluid temperatures, pressures and flow rates, and controller signals. Loss-of-coolant type anomaly in the cold trap operation was generated by temporarily choking one of the blowers, which resulted in temperature and flow rate spikes. The input layer of the autoencoder consisted of all the variables involved in monitoring the cold trap. The LSTM autoencoder was trained on the data corresponding to cold trap startup and normal operation regime, with the loss function calculated as the mean absolute error (MAE). The loss during training was determined to follow log-normal density distribution. During monitoring, we investigated a performance of the LSTM autoencoder for different loss threshold values, set at a progressively increasing number of standard deviations from the mean. The anomaly signal in the data was gradually attenuated, while preserving the noise of the original time series, so that the signal-to-noise ratio (SNR) averaged across all sensors decreased below unity. Results demonstrate detection of anomalies with sensor-averaged SNR < 1.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

FY 2019 Site-Directed Research & Development (Annual Report Overview)

This overview of the Fiscal Year 2019 Site-Directed Research & Development program and the Nevada National Security Site contains information regarding the program’s history and growth, leadership, project selection process, present areas of research, highlights of significant accomplishments and awards, noteworthy people, and performance metrics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic and Impedance Analysis of Fe 2 O 3 Nanoparticles for Chemical Warfare Agent Sensing Applications

A dire need for real-time detection of toxic chemical compounds exists in both civilian and military spheres. In this paper, we demonstrate that inexpensive, commercially available Fe 2 O 3 nanoparticles are capable of selective sensing of chemical warfare agents (CWAs) using frequency-dependent impedance spectroscopy, with additional potential as an orthogonal magnetic sensor. X-ray magnetic circular dichroism analysis shows that Fe 2 O 3 nanoparticles possess moderately lowered moment upon exposure to 2-chloroethyl ethyl sulfide (2-CEES) and diisopropyl methylphosphonate (DIMP) and significantly lowered moment upon exposure to dimethyl methylphosphonate (DMMP) and dimethyl chlorophosphate (DMCP). Associated X-ray absorption spectra confirm a redox reaction in the Fe 2 O 3 nanoparticles due to CWA structural analog exposure, with differentiable energy-dependent features that suggest selective sensing is possible, given the correct method. Impedance spectroscopy performed on samples dosed with DMMP, DMCP, and tabun (GA, chemical warfare nerve agent) showed strong, differentiable, frequency-dependent responses. The frequency profiles provide unique “shift fingerprints” with which high specificity can be determined, even amongst similar analytes. The results suggest that frequency-dependent impedance fingerprinting using commercially available Fe 2 O 3 nanoparticles as a sensor material is a feasible route to selective detection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Field-Scale Lysimeter Studies of Glass and Cementitious Waste Forms at the Hanford Site - 20392

The Hanford site Integrated Disposal Facility (IDF) will receive waste forms from vitrification activities at the Hanford Waste Treatment and Immobilization Plant (WTP). The waste form inventory to be disposed of at the IDF will consist of vitrified low-activity waste (LAW) in glass forms and solidified (or encapsulated) secondary wastes in cementitious forms. The IDF is a near-surface burial facility located near Hanford's Waste Treatment and Immobilization Plant in the 200 East Area of the site's Central Plateau. An extensive set of laboratory experimental data has been collected to support IDF performance assessment calculations of the eventual degradation of waste forms and mobility of contaminants. This paper describes the start of a field experiment to generate waste-form performance data on a larger scale (tens of centimeters), over a longer duration (five years or more), and under field conditions representative of the IDF. Results from this study are expected to improve model descriptions of contaminant mobility, reduce uncertainties about the representativeness of laboratory results in the IDF performance assessment, improve stakeholder confidence in the safe disposal of treated waste at the IDF, and facilitate the adoption of informed facility designs with the potential to reduce operational costs. A lysimeter test facility near Hanford's 200 West Area has been repurposed to carry out long-term assessments of waste forms buried in sediments excavated from the IDF. The waste forms are buried in large drainage lysimeters, open caissons that are two meters in diameter and three meters deep. Waste forms are buried in up to six locations in each lysimeter. Samplers collect pore water and drainage water beneath the waste forms and air from the pore space adjacent to waste forms. Sensors measure temperature, soil water content, soil water tension, and drainage flux. One lysimeter containing cementitious waste forms and one containing glass waste forms have been completed, along with a control lysimeter (without waste forms). The cementitious waste forms are Cast Stone grout formulations using a liquid secondary waste simulant and a generic Hanford high-salt simulant, as well as a hydrated lime-based grout formulation using a liquid secondary waste simulant. Technetium-99 and iodine-127 were added as tracers to monitor contaminant mobility. Glass waste forms were fabricated in two formulations (LAWA44 and ORLEC28), with rhenium and molybdenum tracers to monitor waste form degradation. The predicted performance of the waste forms in the lysimeters was modeled prior to installation to determine waste form size, tracer concentration/activity, and locations of sensors and samplers. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integration of the FastIC front-end electronics into the Picosec MicroMegas detector

The Picosec MicroMegas collaboration aims to develop gaseous fast-timing detectors; experimentally, intrinsic time resolutions from around 50 ps to better than 20 ps are obtained, depending on the exact detector configuration. Parts of developments focus on exploring various options of fast-timing multi-channel front-end electronics, to meet the data processing demands of experimental applications. One option is the FastIC, which was developed for reading out positive and negative input polarity sensors with intrinsic amplification. In this paper, the first results from reading out the gaseous Picosec MicroMegas detector with the FastIC are presented. In laboratory studies, a basic description of the data processing chain was performed using a function generator. The results from test beam measurements are used to characterise the timing performance and the charge processing of the combination of FastIC and Picosec MicroMegas, as well as to demonstrate the possibility of a multi-channel detector readout. Although the timing-at-threshold level of the FastIC introduces a time walk of around 1.5 ns, time resolutions of around 50 ps have been achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ambient Noise Attenuation Tomography Reveals an Asymmetric Damage Zone Across San Jacinto Fault Near Anza, California

Here, we perform seismic attenuation tomography of the shallow structure for the San Jacinto Fault in the Ramona Reservation of southern California. The study uses ambient seismic noise recorded by a linear array of 65 3-C sensors across the fault. We extract amplitude decay information, with uncertainty, from noise interferometry functions. To account for strong heterogeneities in the complex shallow fault zone structure, we apply a frequency-dependent amplitude correction for focusing/defocusing effects using inverted phase velocity maps obtained by solving the transport equation. We then estimate the attenuation structure based on the linear station-triplet method for both Love and Rayleigh waves. The attenuation tomography indicates strong attenuation correlated with known San Jacinto Fault surface traces. The Love wave attenuation tomography reveals an asymmetric damage zone that exists primarily on the fault side with faster seismic velocity, consistent with earthquake ruptures on a fault bimaterial interface with preferred propagation direction to the northwest.

58 GEOSCIENCES↗

Fiber coupled laser ultrasound system using a single mode hollow core fiber for excitation laser: Theory and demonstration for on-machine thickness gauging

Laser ultrasound (LU) is a technique that uses a pump laser and a probe laser to optically generate and detect elastic waves in a material. Despite its advantages over traditional contact transducer-based ultrasound, industrial adoption has been limited by complex optical setups and the inability of multi-mode fibers to deliver a stable Gaussian profile for the pump laser. Here, we report a fully fiber-coupled thermoelastic LU system that uses an anti-resonant hollow-core single-mode fiber to deliver 1 mJ nanosecond pulses of 1064 nm light, while preserving the fundamental Gaussian mode (pump laser). When combined with a fiber-coupled interferometer (probe laser), a small, flexible, and environmentally robust sensor capable of optically generating and detecting high frequency broadband ultrasound is realized. We demonstrate such an LU system implemented in situ on a four-axis precision lathe. High-resolution thickness gauging is performed, before and after precision cutting, by exciting and measuring a zero-group velocity guided wave mode. The measurements are verified with ex-situ traceable coordinate measuring machine data. Mean absolute deviations of 0.1%, of nominal thickness, before cutting, and 0.2% and 0.3%, after stepped and tapered cuts, respectively, are reported. A theoretical background for thermoelastic ultrasound generation in an elastic waveguide is also presented. Attention is given to the effect of the pump laser profile on wave generation to elucidate the importance of using single-mode laser light. The fiber-coupled system demonstrated is well-suited for use in scientific and engineering sensing applications and facilitates the adoption of LU for industrial non-destructive testing.

Engineering↗

Kinetic equilibrium reconstructions of plasmas in the MAST database and preparation for reconstruction of the first plasmas in MAST upgrade

Reconstructions of plasma equilibria using magnetic sensors were routine during operation of the Mega Ampere Spherical Tokamak (MAST) device, but reconstructions using kinetic profiles were not. These are necessary for stability and disruption analysis of the MAST database, as well as for operation in the upgrade to the device, MAST-U. The three-dimensional (3D) code VALEN is used to determine eddy currents in the 3D vessel structures for vacuum coil test shots, which are then mapped to effective resistances in the two-dimensional vessel groupings in the EFIT equilibrium reconstruction code to be used in conjunction with nearby loop voltage measurements for estimated currents in the structures during reconstruction. Kinetic equilibrium reconstructions with EFIT, using all available magnetic sensors as well as Thomson scattering measurements of electron temperature and density, charge exchange recombination spectroscopy measurements of ion temperature, and internal magnetic field pitch angle measurements from a motional Stark effect (MSE) diagnostic are performed for a large database of MAST discharges. Excellent convergence errors are obtained for the portions of the discharges where the stored energy was not too low, and it is found that reconstructions performed with temperature and density measurements but without MSE data usually already match the pitch angle measurements well. A database of 275 kinetic equilibria is used to test the ideal MHD stability calculation capability for MAST. In conclusion, the necessary changes to conducting structure in VALEN, and diagnostic setup in EFIT have been completed for the upgrade from MAST to MAST-U, enabling kinetic reconstructions to commence from the first plasma discharges of the upgraded device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast Relaxation on Qutrit Transitions of Nitrogen-Vacancy Centers in Nanodiamonds

Thanks to their versatility, nitrogen-vacancy (N-𝑉) centers in nanodiamonds have been widely adopted as nanoscale sensors. However, their sensitivities are limited by their short coherence times relative to N-𝑉⁢s in bulk diamond. A more complete understanding of the origins of decoherence in nanodiamonds is critical to improving their performance. Here we present measurements of fast spin relaxation on qutrit transitions between the energy eigenstates composed of the 𝑚 𝑠 =|±1⟩ states of the N-𝑉 − electronic ground state in approximately 40-nm nanodiamonds under ambient conditions. For frequency splittings between these states of 20 MHz or less the maximum theoretically achievable coherence time of the N-𝑉 spin is approximately 2 orders of magnitude shorter than would be expected if the N-𝑉 spin is treated as a qubit. We attribute this fast relaxation to electric field noise. We observe a strong falloff of the qutrit relaxation rate with the splitting between the states, suggesting that, whenever possible, measurements with N-𝑉⁢s in nanodiamonds should be performed at moderate axial magnetic fields (>60 G). We also observe that the qutrit relaxation rate changes with time. As a result, these findings indicate that surface electric field noise is a major source of decoherence for N-𝑉⁢s in nanodiamonds.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Detecting Spin-Bath Polarization with Quantum Quench Phase Shifts of Single Spins in Diamond

Single-qubit sensing protocols can be used to measure qubit-bath coupling parameters. However, for sufficiently large coupling, the sensing protocol itself perturbs the bath, which is predicted to result in a characteristic response in the sensing measurements. Here, we observe this bath perturbation, also known as a quantum quench, by preparing the nuclear spin bath of a nitrogen-vacancy (NV) center in polarized initial states and performing phase-resolved spin-echo measurements on the NV electron spin. These measurements reveal a time-dependent phase determined by the initial state of the bath. We derive the relationship between the sensor phase and the Gaussian spin-bath polarization and apply it to reconstruct both the axial and transverse polarization components. Using this insight, we optimize the transfer efficiency of our dynamic nuclear polarization sequence. This technique for directly measuring bath polarization may assist in preparing high-fidelity quantum memory states, improving nanoscale NMR methods, and investigating non-Gaussian quantum baths.

36 MATERIALS SCIENCE↗

Development and Evaluation of Chip-Enabled Raised Pavement Markers for Lane Line Detection

Increased energy consumption from autonomous vehicle (AV) sensors and computational load as well as upfront costs of sensors are barriers to broad AV adoption. For high quality and reliable perception of the driving environment, incoming data from multiple sensors need to be fused together using advanced computational algorithms, which requires a high compute load. As an alternative, infrastructure-based sensors can be designed to facilitate perception and sensing by supporting vehicle-to-infrastructure (V2I) information exchange. This work presents the initial development and evaluation of a novel energy efficient infrastructure-based sensor. The sensor, a chip-enabled raised pavement marker (CERPM), is capable of wireless communications to exchange environment information with AVs. As a test case, the developed CERPM is applied in real-world driving to perform lane line and drivable region detection for an AV. It is shown that CERPMs can be utilized to effectively detect the lane line and drivable region, which can improve perception while reducing the compute load.

Sharma, Sachin↗

Location generalizability of image-based air quality models

This paper is to be submitted at the IEEE/CVF Winter Conference on Applications of Computer Vision (WACV) Computer Vision for Earth Observation workshop. The full paper abstract is below: The ability to rapidly quantify atmospheric pollutants is important both for global emissions monitoring and for mitigating the adverse effects that follow a hazardous chemical release. In the aftermath of a chemical release, imagery is often the only available resource to assess local conditions. Recent work has demonstrated initial success in predicting particulate matter pollution from imagery; however, these results are tied to a specific site and do not generalize to new geographic locations. In this work, we seek to understand how easily deep learning models generalize to new locations in the context of image-based air quality assessments, targeting two distinct tasks: (1) broad measures of particulate matter pollution, and (2) the mass of a given chemical released in hazardous plumes. For the latter, we focus on sulfur dioxide, a toxic aerosol and a major component of particulate matter pollution caused by industrial fossil fuel consumption. To develop a model that operates in the widest possible range of environments, we test different training strategies, including the use of new geolocation foundation models. The best performing models achieve >80% accuracy when evaluating unseen imagery at previously seen sites, but we find significant drops in performance when evaluating imagery from unseen sites, at best 65%. Additionally, we present the public release of the National Parks Air Quality Index Dataset, a new medium-sized dataset that pairs imagery with sensor-based air quality measurements at 15 different national parks.

Byler, Eleanor B. [BATTELLE (PACIFIC NW LAB)]↗

UNCERTAINTY-AWARE DEEP LEARNING FRAMEWORK FOR FORECASTING COASTAL WATER LEVEL IN VIRGINIA BEACH

Coastal areas like Virginia Beach, USA, are increasingly vulnerable to flooding. To mitigate the impact of flooding, it is crucial for the City of Virginia Beach to have reliable 72-hour-ahead (3 days) forecasts of water levels at key gauge locations. To support this effort, several sensors have been installed throughout the city to monitor water levels and other environmental parameters such as wind speed, precipitation, and atmospheric pressure. Leveraging sensor data from one of these locations, we developed an uncertainty-aware deep learning model to forecast water levels. We employed deep quantile regression (DQR) to quantify variability in the predictions and examined the performance of three different model architectures. In addition to exclusively including historical data, we investigated the improvement wind forecasts provide to the accuracy of 72-hour-ahead water level predictions. The results show a twelvefold improvement in the flood forecast for a real flooding event.

Hasan, Mahmud [Thomas Jefferson National Accelerat↗

Modified Virtual Oscillator Based Operation of Grid Forming Converters with Single Voltage Sensor

Virtual oscillator based control architecture for grid forming converter with inner current control loop for additional objective accomplishments is proposed in this paper. In general, virtual oscillator is based on Lienard type of oscillator equation with a cubic nonlinearity. Virtual oscillator alone cannot accommodate unbalanced or harmonic mitigation while operating converters in grid forming mode. Therefore, to accomplish better tracking performance, incorporating the provision for nonlinear and/or unbalanced loads, an inner current control loop is utilized which is based upon Lyapunov energy function type control architecture due to its advantages. To reduce the overall cost of implementation and ensure proper phase difference in the generated voltages, the implemented virtual oscillator operates with only one voltage feedback from the point of common coupling as presented in this paper. To verify the effectiveness of the proposed approach, the overall system has been modeled in MATTLAB/Simulink and PLECS domain and case studies showing the successful production of low harmonic load voltages under nonideal loading condition along with other important results are presented in this paper.

dual second order generalized integrator↗