Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sampling statistics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Statistics of base polytopes in F-theory

We propose a new statistical ensemble of toric bases for elliptic Calabi-Yaus used in F-theory models, by focusing on only the convex hull of the base, i.e., the base polytope. This physically motivated coarse-graining greatly simplifies the combinatorial complexity of the part of the 4d F-theory landscape with toric bases. We develop a Monte Carlo approach that randomly samples the base polytopes within fixed boxes, with proper statistical weights. We first apply the algorithm to the set of 2d base polytopes, generating an enlarged set of toric 2d bases that include certain types of codimension-two (4,6) points, and we validate our approach against exact numbers. We then explore the set of 3d base polytopes which fit in a set of “maximal” 3d boxes, and estimate the total number of inequivalent 3d base polytopes to be 10 85 –10 90 . We provide statistical data such as the distribution of non-Higgsable gauge groups on these bases. Amusingly, a similar method can also be applied to generate reflexive polytopes in various dimensions. In both the reflexive and base polytope cases, the number of relevant polytopes obeys a Gaussian distribution as a function of the number of vertices, which can be understood in terms of other results on random polytopes in the math literature.

Differential and algebraic geometry↗

Time correlation between the radio and gamma-ray activity in blazars and the production site of the gamma-ray emission

In order to determine the location of the gamma-ray emission site in blazars, we investigate the time-domain relationship between their radio and gamma-ray emission. Light-curves for the brightest detected blazars from the first 3 years of the mission of the Fermi Gamma-ray Space Telescope are cross-correlated with 4 years of 15GHz observations from the OVRO 40-m monitoring program. The large sample and long light-curve duration enable us to carry out a statistically robust analysis of the significance of the cross-correlations, which is investigated using Monte Carlo simulations including the uneven sampling and noise properties of the light-curves. Modeling the light-curves as red noise processes with power-law power spectral densities, we find that only one of 41 sources with high quality data in both bands shows correlations with significance larger than 3σ (AO0235+164), with only two more larger than even 2.25σ (PKS 1502+106 and B2 2308+34). Additionally, we find correlated variability in Mrk 421 when including a strong flare that occurred in July-September 2012. These results demonstrate very clearly the difficulty of measuring statistically robust multiwavelength correlations and the care needed when comparing light-curves even when many years of data are used. This should be a caution. In all four sources the radio variations lag the gamma-ray variations, suggesting that the gamma-ray emission originates upstream of the radio emission. Continuous simultaneous monitoring over a longer time period is required to obtain high significance levels in cross-correlations between gamma-ray and radio variability in most blazars.

79 ASTRONOMY AND ASTROPHYSICS↗

Ion chamber absorbed dose calibration coefficients, N{sub D,w}, measured at ADCLs: Distribution analysis and stability

Purpose: To analyze absorbed dose calibration coefficients, N{sub D,w}, measured at accredited dosimetry calibration laboratories (ADCLs) for client ionization chambers to study (i) variability among N{sub D,w} coefficients for chambers of the same type calibrated at each ADCL to investigate ion chamber volume fluctuations and chamber manufacturing tolerances; (ii) equivalency of ion chamber calibration coefficients measured at different ADCLs by intercomparing N{sub D,w} coefficients for chambers of the same type; and (iii) the long-term stability of N{sub D,w} coefficients for different chamber types by investigating repeated chamber calibrations. Methods: Large samples of N{sub D,w} coefficients for several chamber types measured over the time period between 1998 and 2014 were obtained from the three ADCLs operating in the United States. These are analyzed using various graphical and numerical statistical tests for the four chamber types with the largest samples of calibration coefficients to investigate (i) and (ii) above. Ratios of calibration coefficients for the same chamber, typically obtained two years apart, are calculated to investigate (iii) above and chambers with standard deviations of old/new ratios less than 0.3% meet stability requirements for accurate reference dosimetry recommended in dosimetry protocols. Results: It is found that N{sub D,w} coefficients for a given chamber type compared among different ADCLs may arise from differing probability distributions potentially due to slight differences in calibration procedures and/or the transfer of the primary standard. However, average N{sub D,w} coefficients from different ADCLs for given chamber types are very close with percent differences generally less than 0.2% for Farmer-type chambers and are well within reported uncertainties. Conclusions: The close agreement among calibrations performed at different ADCLs reaffirms the Calibration Laboratory Accreditation Subcommittee process of ensuring ADCL conformance with National Institute of Standards and Technology standards. This study shows that N{sub D,w} coefficients measured at different ADCLs are statistically equivalent, especially considering reasonable uncertainties. This analysis of N{sub D,w} coefficients also allows identification of chamber types that can be considered stable enough for accurate reference dosimetry.

07 ISOTOPE AND RADIATION SOURCES↗

A microscopic and crystallographic study of proton irradiated alloy 718

Solution annealing and age hardening are important processes for achieving good engineering and chemical properties of alloy 718. The composition of alloy 718 also plays an important role as it can affect both mechanical (γ”- and γ’-phase formation) and irradiation behaviors. Therefore, in this study five different sets of alloy 718 samples with two different chemical compositions were fabricated using different processing conditions and irradiated up to 4 dpa. Based on the effects of irradiation on the microstructural data of γ”- and γ’-phases, irradiation-induced dislocation statistics, and crystallographic data, it can be inferred that the samples processed at high solution annealing temperature (1093°C) behave better under irradiation compared to the samples processed at low solution annealing temperatures (945 and 1065°C).

36 MATERIALS SCIENCE↗

Importance sampling : promises and limitations.

Importance sampling is an unbiased sampling method used to sample random variables from different densities than originally defined. These importance sampling densities are constructed to pick 'important' values of input random variables to improve the estimation of a statistical response of interest, such as a mean or probability of failure. Conceptually, importance sampling is very attractive: for example one wants to generate more samples in a failure region when estimating failure probabilities. In practice, however, importance sampling can be challenging to implement efficiently, especially in a general framework that will allow solutions for many classes of problems. We are interested in the promises and limitations of importance sampling as applied to computationally expensive finite element simulations which are treated as 'black-box' codes. In this paper, we present a customized importance sampler that is meant to be used after an initial set of Latin Hypercube samples has been taken, to help refine a failure probability estimate. The importance sampling densities are constructed based on kernel density estimators. We examine importance sampling with respect to two main questions: is importance sampling efficient and accurate for situations where we can only afford small numbers of samples? And does importance sampling require the use of surrogate methods to generate a sufficient number of samples so that the importance sampling process does increase the accuracy of the failure probability estimate? We present various case studies to address these questions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The potential effect of metallothionein 2A - 5 A/G single nucleotide polymorphism on blood cadmium, lead, zinc and copper levels

Metallothioneins (MTs) are low molecular weight, cysteine-rich, metal-binding proteins. Because of their rich thiol groups, MTs bind to the biologically essential metals and perform these metals' homeostatic regulations; absorb the heavy metals and assist with their transportation and extraction. The aim of this study was to investigate the association between the metallothionein 2A (MT2A) core promoter region - 5 A/G single nucleotide polymorphism (SNP) and Cd, Pb, Zn and Cu levels in the blood samples. MT2A polymorphism was determined by the standard polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) technique using the 616 blood samples and the genotype frequencies were found as 86.6% homozygote typical (AA), 12.8% heterozygote (AG) and 0.6% homozygote atypical (GG). Metal levels were analyzed by dual atomic absorption spectrophotometer system and the average levels of Cd, Pb, Zn and Cu in the blood samples were 1.69 {+-} 1.57 ppb, 30.62 {+-} 14.13 ppb, 0.98 {+-} 0.49 ppm and 1.04 {+-} 0.45 ppm, respectively. As a result; highly statistically significant associations were detected between the - 5 A/G core promoter region SNP in the MT2A gene and Cd, Pb and Zn levels (p = 0.004, p = 0.012 and p = 0.002, respectively), but no association was found with Cu level (p = 0.595). Individuals with the GG genotype had statistically lower Zn level and higher Cd and Pb levels in the blood samples than individuals with AA and AG genotypes. This study suggests that having the GG genotype individuals may be more sensitive for the metal toxicity and they should be more careful about protecting their health against the toxic effects of the heavy metals. - Highlights: > MT2A -5A/G SNP has strong effect on the Cd, Pb and Zn levels in the blood. > MT2A GG individuals should be more careful for their health against metal toxicity. > This SNP might be considered as a biomarker for risk of disease related to metals.

60 APPLIED LIFE SCIENCES↗

Field evaluation of remote wind sensing technologies: Shore-based and buoy mounted LIDAR systems

In developing a national energy strategy, the United States has a number of objectives, including increasing economic growth, improving environmental quality, and enhancing national energy security. Wind power contributes to these objectives through the deployment of clean, affordable and reliable domestic energy. To achieve U.S. wind generation objectives, the Wind and Water Power Program within the Department of Energy’s (DOE) Office of Energy Efficiency and Renewable Energy (EERE) instituted the U.S. Offshore Wind: Removing Market Barriers Program in FY 2011. Accurate and comprehensive information on offshore wind resource characteristics across a range of spatial and temporal scales is one market barrier that needs to be addressed through advanced research in remote sensing technologies. There is a pressing need for reliable offshore wind-speed measurements to assess the availability of the potential wind energy resource in terms of power production and to identify any frequently occurring spatial variability in the offshore wind resource that may impact the operational reliability and lifetime of wind turbines and their components and to provide a verification program to validate the “bankability” of the output of these alternative technologies for use by finance institutions for the financing of offshore wind farm construction. The application of emerging remote sensing technologies is viewed as a means to cost-effectively meet the data needs of the offshore wind industry. In particular, scanning and buoy mounted LIDAR have been proposed as a means to obtain accurate offshore wind data at multiple locations without the high cost and regulatory hurdles associated with the construction of offshore meteorological towers. However; before these remote sensing technologies can be accepted the validity of the measured data must be evaluated to ensure their accuracy. The proposed research will establish a unique coastal ocean test-bed in the Mid-Atlantic for the evaluation of LIDAR-based wind measurement systems to validate the accuracy of remotely measured wind data in marine applications. Specifically, the test-bed will be utilized to systematically evaluate the capability of emerging scanning LIDAR and buoy mounted vertically profiling LIDAR by: (1) Evaluating a fixed scanning LIDAR against land-based 50 and 60 meter high meteorological masts fitted with research quality cup-vane and/or sonic anemometers; (2) Evaluating a buoy mounted vertically profiling LIDAR fixed on land and floating in a sheltered bay against a co-located 60 meter high meteorological mast fitted with a research quality cup-vane and/or sonic anemometers and the fixed scanning LIDAR; and (3) Offshore field evaluation of both LIDAR platforms through a comparison of the fixed scanning LIDAR data and data obtained by the buoy mounted LIDAR located 10 miles offshore. The proposed research will systematically validate Light Detection and Ranging (LIDAR) based wind measurement systems and assess the temporal and spatial variability of the offshore wind resource in the Mid-Atlantic east of New Jersey. The goal of the proposed project is to address the technical and commercial challenges of the offshore wind energy industry by validating and assessing cost-effective, over ocean wind resource characterization technologies. The objective is to systematically evaluate the capability of both scanning and vertically profiling LIDARs to accurately measure 3D wind fields through comparison with fixed met masts and intercomparison among LIDAR platforms. Once validated, data collected by both buoy mounted vertically profiling LIDARs and shore-based, pulsed horizontally scanning LIDARs can be used to accurately assess offshore wind resources and to quantify the spatial and temporal variability in the offshore wind fields. One of the fundamental research questions to be addressed in phase 1 is the assessment of various measurement and data processing schemes to retrieve accurate wind vectors in the marine environment over large sampling ranges (10 to 12 km) and varying atmospheric aerosol levels. Atmospheric conditions and aerosol content within the coastal ocean region of the Mid-Atlantic seaboard of the US can vary significantly over short time periods in response to frontal passages and extratropical and tropical low pressure system passage offshore of the coast. Since aerosols provide the scattering medium for the determination of LIDAR Doppler shifts in the atmosphere the accuracy and range of LIDAR derived velocity measurements as a function of variation in aerosol content in the marine environment is a key research question to be addressed. In phase 1, it is desired to capture as much variation in atmospheric conditions and aerosol content as possible. To this end, collocated measurements of LIDAR and standard anemometer wind fields will be captured by the project PIs over all four seasons and during specific events (e.g., coastal low pressure system passage) in year 1. Additionally, since the meteorological masts are permanent structures, additional events can be captured over the three year duration of the field research project. All research instruments are owned by Fishermen’s Energy and made available to the PIs though a lease agreement as part of the DOE grant. Energy Fishermen’s Energy will be responsible for the operation and maintenance of the scanning LIDAR and met mast anemometers. On a daily basis, environmental data and systems performance indicators will be transmitted from each measurement station to the Fishermen’s project team consisting of both in-house personnel and equipment manufacturer engineers. Data sets include compiled LIDAR files as well as data sets from ancillary sensors. Diagnostic parameters to be monitored include standard deviations of measured values, battery levels and charging systems output, and the operational status. Once data have been confirmed as complete and reliable, files will be transferred to the Garrad Hassan (a subcontractor to Fishermen’s Energy) for incorporation in to the validation database, which is accessible to other scientific team members. Data collection times and durations will be determined by the PI and Co-PIs in consultation with instrument engineers to ensure the capture of data representative of the expected range of mid-Atlantic atmospheric conditions (e.g., temperature, moisture, coastal low pressure systems, tropical systems, rain, snow, fog). The collection and processing of the data is a function of site specific measurement requirements (Kelley et.al. 2007; Hannon et.al. 2008). To determine the optimal profiles of wind speed and direction from the LIDAR radial velocities as a function of azimuth angle, rigorous estimates of the bias and random error of each radial velocity estimate are required. Lockheed Martin Coherent Technologies, Inc., under contract with Fishermen’s Energy, will provide analyses of raw and processed data using various scan patterns to determine optimal performance settings for the pulsed scanning LIDAR. Once optimized, appropriate processing and analyses techniques will be evaluated by Garrad Hassan for use in validating the accuracy of the LIDAR wind field measurements against the standard anemometer measurements from the meteorological masts. The most attractive capability of the scanning LIDAR is the ability to provide high spatial resolution observations in a three-dimensional volume which provides superior statistical accuracy due to the large number of samples obtained. Each radial scan provides measurements in 100 range gates over a distance of 10 to 12 km at an update rate of 5 to 10 Hz and rotation of 2.5° per second. Each rotation at a fixed azimuth requires 2.4 minutes. Depending on the number of azimuths desired a complete scan can take up to 10 minutes or longer to complete. Once collected the radial velocities are processed to produce vector wind velocity estimates based on a set of data distributed in angle and range around points of interest, typically a standard grid within the radial wind map. To calculate wind vectors over a limited spatial area of interest for the comparison of data with other measurement platforms a localized least-squares approach has been applied by Hannon et.al. (2008) and a Variation Assimilation (VAR) processing technique has been applied by Chan and al Assimilation (VAR) processing technique has been applied by Chan and Shao (2006). Additionally, Kelley et.al. (2007) applied a “stare” technique that fixed a scanning LIDAR in both azimuth and elevation angles to measure over collocated sampling volumes of the LIDAR and a 3D sonic anemometer mounted to a fixed mast. Although the stare technique is limited to wind directions aligned with the sampling radial of the LIDAR, it does provide a direct comparison of sampling volumes. Each of the processing techniques described above (and possibly others) will be evaluated to determine the validity of the LIDAR derived wind fields in the marine environment. Numerical methods such as linear regression and comparison of probability density functions of wind fields measured by each instrument platform will be used to assess the processing techniques. Linear regression has the advantage of directly evaluating corresponding pairs of wind data measured by each instrument and can lend insight into deviations and bias between instruments as a function of wind speed. Assessment of the coherency between the probability density function of the wind measured by each instrument provides insight into processes that may not be accurately resolved by each instrument at specific frequencies. Once processed and assessed the most appropriate technique will be utilized to provide valid wind measurements from the pulsed scanning LIDAR. A detailed analysis of the measurement data from the LIDAR and the three meteorological towers and comparison of the coastal wind characteristics from the different systems will be performed by the CO_PI at NREL. This analysis will evaluate how the WT LIDAR performance and measurement of the wind characteristics vary with distance from the LIDAR and by atmospheric conditions; using the tower measurements at different distances (4.8, 9.6, and 19 km) from the LIDAR as a reference. The comparative analysis will include, to the extent possible, evaluation of parameters such as wind speed and direction distributions, wind shear, turbulence intensity and their variations by atmospheric conditions, month or season, and time of day.

17 WIND ENERGY↗

SU-F-I-43: A Software-Based Statistical Method to Compute Low Contrast Detectability in Computed Tomography Images

Purpose: The low contrast detectability (LCD) of a CT scanner is its ability to detect and display faint lesions. The current approach to quantify LCD is achieved using vendor-specific methods and phantoms, typically by subjectively observing the smallest size object at a contrast level above phantom background. However, this approach does not yield clinically applicable values for LCD. The current study proposes a statistical LCD metric using software tools to not only to assess scanner performance, but also to quantify the key factors affecting LCD. This approach was developed using uniform QC phantoms, and its applicability was then extended under simulated clinical conditions. Methods: MATLAB software was developed to compute LCD using a uniform image of a QC phantom. For a given virtual object size, the software randomly samples the image within a selected area, and uses statistical analysis based on Student’s t-distribution to compute the LCD as the minimal Hounsfield Unit’s that can be distinguished from the background at the 95% confidence level. Its validity was assessed by comparison with the behavior of a known QC phantom under various scan protocols and a tissue-mimicking phantom. The contributions of beam quality and scattered radiation upon the computed LCD were quantified by using various external beam-hardening filters and phantom lengths. Results: As expected, the LCD was inversely related to object size under all scan conditions. The type of image reconstruction kernel filter and tissue/organ type strongly influenced the background noise characteristics and therefore, the computed LCD for the associated image. Conclusion: The proposed metric and its associated software tools are vendor-independent and can be used to analyze any LCD scanner performance. Furthermore, the method employed can be used in conjunction with the relationships established in this study between LCD and tissue type to extend these concepts to patients’ clinical CT images.

60 APPLIED LIFE SCIENCES↗

Multiparameter Methods are the New Field in Statistics

During the last decade statistical problems of a new kind have appeared more and more often, in which the dimensionality of observations is large, and the sample size is small or comparable with the dimensionality of observations. These problems may be characterized as multiparameter problems. The theory of multiparameter analysis, proposed by A.N.Kolmogorov and supported by the studies on the spectral theory of random matrices of V. A.Marchenko, L. A.Pastur, V. L.Girko, and others, revealed some specific phenomena appearing in statistics with a large number of weakly dependent variables. Particularly, there are stable relations between the principal parts of parameter set functions and the set of observed variables, which may be used to improve the statistical analysis. The use of these phenomena allows one to develop a thorough, always stable, and approximately optimal (irrespective of samples) versions of mostly used statistical procedures. The multiparameter versions of the discriminant analysis are of special interest.

97 MATHEMATICS AND COMPUTING↗

Exploration of multifidelity UQ sampling strategies for computer network applications.

Network modeling is a powerful tool to enable rapid analysis of complex systems that can be challenging to study directly using physical testing. Here, two approaches are considered: emulation and simulation. The former runs real software on virtualized hardware, while the latter mimics the behavior of network components and their interactions in software. Although emulation provides an accurate representation of physical networks, this approach alone cannot guarantee the characterization of the system under realistic operative conditions. Operative conditions for physical networks are often characterized by intrinsic variability (payload size, packet latency, etc.) or a lack of precise knowledge regarding the network configuration (bandwidth, delays, etc.); therefore uncertainty quantification (UQ) strategies should be also employed. UQ strategies require multiple evaluations of the system with a number of evaluation instances that roughly increases with the problem dimensionality, i.e., the number of uncertain parameters. It follows that a typical UQ workflow for network modeling based on emulation can easily become unattainable due to its prohibitive computational cost. In this paper, a multifidelity sampling approach is discussed and applied to network modeling problems. The main idea is to optimally fuse information coming from simulations, which are a low-fidelity version of the emulation problem of interest, in order to decrease the estimator variance. By reducing the estimator variance in a sampling approach it is usually possible to obtain more reliable statistics and therefore a more reliable system characterization. Several network problems of increasing difficulty are presented. For each of them, the performance of the multifidelity estimator is compared with respect to the single fidelity counterpart, namely, Monte Carlo sampling. For all the test problems studied in this work, the multifidelity estimator demonstrated an increased efficiency with respect to MC.

97 MATHEMATICS AND COMPUTING↗

Modeling neutral defects in III-V ternary alloys with a special quasirandom structure: Analysis of As- and III-site point defects in InGaAs

While first-principles density functional theory modeling has become a vital tool to investigate defect properties in semiconductors, the lack of crystalline periodicity in pseudobinary random composition alloys, such as In 1−𝑥 ⁢Ga 𝑥 ⁢As, complicates such analyses. We present a simulation strategy to systematically take into account the variability in the local defect environment in order to predict statistical properties of neutral intrinsic defects in In 1−𝑥⁢ Ga 𝑥 ⁢As. We use a comprehensive sampling from a modest-sized 64-atom special quasirandom structure (SQS) to define a statistically representative set of defects, and use a 512-atom hypercell, a 2 × 2 × 2 supercell of SQS supercells, to achieve cell-size convergence. We articulate an equivalent site principle and describe how it constrains atomic chemical reference energies in computation of defect formation energies in pseudobinary alloys. A simple protocol for estimating reference energies for the Ga and In atoms sharing the III site succeeds in obtaining the equivalence of defects at Ga-sites and In sites in the SQS supercell, (<30 meV differences in average formation energies). For III-site defects, such as the As antisite As III , the statistical variability in formation energies is modest, ≈ 0.1–0.2 eV. The variability in formation energy at As-site defects, such as the As vacancy 𝑣 As , can be much larger, >1 eV. The As antisite is shown to be a low-energy defect and the most likely to be present in as-grown materials, just as in GaAs. All other defects are higher-energy defects unlikely to be important in native material, but potentially important in radiation-damaged material. With a strong variability in defect energies, especially on the As-site, explicit consideration of statistical variability due to compositional randomness will be imperative for meaningful and quantitative comparisons to experiment.

Density functional theory↗

Studying vapor-liquid transition using a generalized ensemble

Homogeneous vapor-liquid nucleation is studied using the generalized Replica Exchange Method (gREM). The generalized ensemble allows the study of unstable states that cannot directly be studied in the canonical ensemble. Along with replica exchange, this allows for efficient sampling of the multiple states in a single simulation. Statistical Temperature Weighted Histogram Analysis Method is used for postprocessing to get a continuous free energy curve from bulk vapor to bulk liquid. gREM allows the study of planar, cylindrical, and spherical interfaces in a single simulation. The excess Gibbs free energy for the formation of a spherical liquid droplet in vapor for a Lennard-Jones system is calculated from the free energy curve and compared against the umbrella sampling results. The nucleation free energy barrier obtained from gREM is then used to calculate the nucleation rate without relying on any classification scheme for separating the vapor and liquid.

Ballal, Deepti (ORCID:0000000315694749)↗

A NEW TEST OF THE STATISTICAL NATURE OF THE BRIGHTEST CLUSTER GALAXIES

A novel statistic is proposed to examine the hypothesis that all cluster galaxies are drawn from the same luminosity distribution (LD). In such a 'statistical model' of galaxy LD, the brightest cluster galaxies (BCGs) are simply the statistical extreme of the galaxy population. Using a large sample of nearby clusters, we show that BCGs in high luminosity clusters (e.g., L {sub tot} {approx}> 4 x 10{sup 11} h {sup -2} {sub 70} L {sub sun}) are unlikely (probability {<=}3 x 10{sup -4}) to be drawn from the LD defined by all red cluster galaxies more luminous than M{sub r} = -20. On the other hand, BCGs in less luminous clusters are consistent with being the statistical extreme. Applying our method to the second brightest galaxies, we show that they are consistent with being the statistical extreme, which implies that the BCGs are also distinct from non-BCG luminous, red, cluster galaxies. We point out some issues with the interpretation of the classical tests proposed by Tremaine and Richstone (TR) that are designed to examine the statistical nature of BCGs, investigate the robustness of both our statistical test and those of TR against difficulties in photometry of galaxies of large angular size, and discuss the implication of our findings on surveys that use the luminous red galaxies to measure the baryon acoustic oscillation features in the galaxy power spectrum.

79 ASTRONOMY AND ASTROPHYSICS↗

The environmental dependence of the stellar mass of active galactic nucleus host galaxies and dependence of the clustering properties of active galactic nucleus host galaxies on the stellar mass

Abstract We used two volume‐limited active galactic nucleus (AGN) host galaxy samples constructed by Deng & Wen (2020, RMxAA , 56, 87), and explored the environmental dependence of the stellar mass of AGN host galaxies. In the luminous volume‐limited AGN host galaxy sample, the stellar mass of AGN host galaxies apparently depends on local environments: high mass AGN host galaxies exist preferentially in the dense regions of the universe, while low mass AGN host galaxies are located preferentially in low density regions. But in the faint volume‐limited AGN host galaxy sample, this dependence is fairly weak. We also examined the dependence of the clustering properties of AGN host galaxies on the stellar mass by cluster analysis, and found that in the luminous volume‐limited AGN host galaxy sample, low mass AGN host galaxies preferentially form isolated galaxies, close pairs, and small groups, while high mass AGN host galaxies preferentially inhabit the dense groups and clusters. A substantial dependence of the clustering properties of AGN host galaxies on the stellar mass is also observed in the faint volume‐limited AGN host galaxy sample, which is inconsistent with the environmental dependence of the stellar mass of AGN host galaxies in the faint volume‐limited AGN host galaxy sample. This is likely due to the galaxy number of the faint volume‐limited AGN host galaxy sample being too small to ensure an ideal statistical analysis.

Deng, Xin‐Fa↗

Breeding Realistic D‐Brane Models

Abstract Intersecting branes provide a useful mechanism to construct particle physics models from string theory with a wide variety of desirable characteristics. The landscape of such models can be enormous, and navigating towards regions which are most phenomenologically interesting is potentially challenging. Machine learning techniques can be used to efficiently construct large numbers of consistent and phenomenologically desirable models. In this work we phrase the problem of finding consistent intersecting D‐brane models in terms of genetic algorithms, which mimic natural selection to evolve a population collectively towards optimal solutions. For a four‐dimensional supersymmetric type IIA orientifold with intersecting D6‐branes, we demonstrate that unique, fully consistent models can be easily constructed, and, by a judicious choice of search environment and hyper‐parameters, of the found models contain the desired Standard Model gauge group factor. Having a sizable sample allows us to draw some preliminary landscape statistics of intersecting brane models both with and without the restriction of having the Standard Model gauge factor.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

PET/CT-guided Interventions: Personnel Radiation Dose

PurposeTo quantify radiation exposure to the primary operator and staff during PET/CT-guided interventional procedures.MethodsIn this prospective study, 12 patients underwent PET/CT-guided interventions over a 6 month period. Radiation exposure was measured for the primary operator, the radiology technologist, and the nurse anesthetist by means of optically stimulated luminescence dosimeters. Radiation exposure was correlated with the procedure time and the use of in-room image guidance (CT fluoroscopy or ultrasound).ResultsThe median effective dose was 0.02 (range 0-0.13) mSv for the primary operator, 0.01 (range 0-0.05) mSv for the nurse anesthetist, and 0.02 (range 0-0.05) mSv for the radiology technologist. The median extremity dose equivalent for the operator was 0.05 (range 0-0.62) mSv. Radiation exposure correlated with procedure duration and with the use of in-room image guidance. The median operator effective dose for the procedure was 0.015 mSv when conventional biopsy mode CT was used, compared to 0.06 mSv for in-room image guidance, although this did not achieve statistical significance as a result of the small sample size (p = 0.06).ConclusionThe operator dose from PET/CT-guided procedures is not significantly different than typical doses from fluoroscopically guided procedures. The major determinant of radiation exposure to the operator from PET/CT-guided interventional procedures is time spent in close proximity to the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A multi-level anomaly detection algorithm for time-varying graph data with interactive visualization

This work presents a novel modeling and analysis framework for graph sequences which addresses the challenge of detecting and contextualizing anomalies in labelled, streaming graph data. We introduce a generalization of the BTER model of Seshadhri et al. by adding flexibility to community structure, and use this model to perform multi-scale graph anomaly detection. Specifically, probability models describing coarse subgraphs are built by aggregating node probabilities, and these related hierarchical models simultaneously detect deviations from expectation. This technique provides insight into a graph's structure and internal context that may shed light on a detected event. Additionally, this multi-scale analysis facilitates intuitive visualizations by allowing users to narrow focus from an anomalous graph to particular subgraphs or nodes causing the anomaly. For evaluation, two hierarchical anomaly detectors are tested against a baseline Gaussian method on a series of sampled graphs. We demonstrate that our graph statistics-based approach outperforms both a distribution-based detector and the baseline in a labeled setting with community structure, and it accurately detects anomalies in synthetic and real-world datasets at the node, subgraph, and graph levels. Furthermore, to illustrate the accessibility of information made possible via this technique, the anomaly detector and an associated interactive visualization tool are tested on NCAA football data, where teams and conferences that moved within the league are identified with perfect recall, and precision greater than 0.786.

97 MATHEMATICS AND COMPUTING↗

Earthworms Exposed to Polyethylene and Biodegradable Microplastics in Soil: Microplastic Characterization and Microbial Community Analysis

While much is known about microplastics in aquatic environments, only few studies have focused on how microplastics interact with terrestrial organisms. The objective of our study was to investigate the interactions of earthworms with microplastics in a natural environment with environmentally realistic plastic concentrations. Here we investigated whether earthworms would ingest microplastics and incorporate them into their bodies and cast, and whether microplastics would alter the intestinal and soil microbiome. Lumbricus terrestris was exposed to two types of mi croplastics, biodegradable polybutylene adipate terephthalate (PBAT) and low-density polyethylene (LDPE) in mesocosoms filled with natural soil. Microplastics were mixed with poplar leaves and earthworms were allowed to forage for food for 20 days. Surface and bulk soil, earthworm cast, and earthworms themselves were sampled and analyzed for plastic content and microbial communities. Earthworms did not show macroscopic health deterioration (weight loss, vitality). We observed microplastics particles in earthworm casts and guts. Raman spectroscopy indicated that PBAT in guts and cast had degraded to some extent; however, LDPE remained unchanged among the different samples. Microbial analysis showed that soil and casts has similar microbial communities; however, they were signicantly different from the guts samples. Microplastic treatments did not result in a statistically signicant change in bacterial richness, diversity or community composition compared to controls. Taken together, our results suggest that, at environmentally realistic concentrations and short exposure times, PBAT and LDPE microplastics do not have adverse effects on Lumbricus terrestris earthworms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗