Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “resonance frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Bubble Measuring Instrument and Method

Method and apparatus are provided for a non-invasive bubble measuring instrument operable for detecting. distinguishing, and counting gaseous embolisms such as bubbles over a selectable range of bubble sizes of interest. A selected measurement volume in which bubbles may be detected is insonified by two distinct frequencies from a pump transducer and an image transducer, respectively. The image transducer frequency is much higher than the pump transducer frequency. The relatively low-frequency pump signal is used to excite bubbles to resonate at a frequency related to their diameter. The image transducer is operated in a pulse-echo mode at a controllable repetition rate that transmits bursts of high-frequency ultrasonic signal to the measurement volume in which bubbles may be detected and then receive, the echo. From the echo or received signal, a beat signal related to the repetition rate may be extracted and used to indicate the presence or absence of a resonant bubble. In a preferred embodiment, software control maintains the beat signal at a preselected frequency while varying the pump transducer frequency to excite bubbles of different diameters to resonate depending on the range of bubble diameters selected for investigation.

Robert Kline-Schoder↗

Bubble Measuring Instrument and Method

Method and apparatus are provided for a non-invasive bubble measuring instrument operable for detecting, distinguishing, and counting gaseous embolisms such as bubbles over a selectable range of bubble sizes of interest. A selected measurement volume in which bubbles may be detected is insonified by two distinct frequencies from a pump transducer and an image transducer, respectively. The image transducer frequency is much higher than the pump transducer frequency. The relatively low-frequency pump signal is used to excite bubbles to resonate at a frequency related to their diameter. The image transducer is operated in a pulse-echo mode at a controllable repetition rate that transmits bursts of high-frequency ultrasonic signal to the measurement volume in which bubbles may be detected and then receives the echo. From the echo or received signal, a beat signal related to the repetition rate may be extracted and used to indicate the presence or absence of a resonant bubble. In a preferred embodiment, software control maintains the beat signal at a preselected frequency while varying the pump transducer frequency to excite bubbles of different diameters to resonate depending on the range of bubble diameters selected for investigation.

Robert Kline-Schoder↗

Bubble Measuring Instrument and Method

Method and apparatus are provided for a non-invasive bubble measuring instrument operable for detecting, distinguishing, and counting gaseous embolisms such as bubbles over a selectable range of bubble sizes of interest. A selected measurement volume in which bubbles may be detected is insonified by two distinct frequencies from a pump transducer and an image transducer, respectively. The image transducer frequency is much higher than the pump transducer frequency. The relatively low-frequency pump signal is used to excite bubbles to resonate at a frequency related to their diameter. The image transducer is operated in a pulse-echo mode at a controllable repetition rate that transmits bursts of high-frequency ultrasonic signal to the measurement volume in which bubbles may be detected and then receives the echo. From the echo or received signal, a beat signal related to the repetition rate may be extracted and used to indicate the presence or absence of a resonant bubble. In a preferred embodiment, software control maintains the beat signal at a preselected frequency while varying the pump transducer frequency to excite bubbles of different diameters to resonate depending on the range of bubble diameters selected for investigation.

Robert Kline-Schoder↗

Bubble measuring instrument and method

Method and apparatus are provided for a non-invasive bubble measuring instrument operable for detecting, distinguishing, and counting gaseous embolisms such as bubbles over a selectable range of bubble sizes of interest. A selected measurement volume in which bubbles may be detected is insonified by two distinct frequencies from a pump transducer and an image transducer, respectively. The image transducer frequency is much higher than the pump transducer frequency. The relatively low-frequency pump signal is used to excite bubbles to resonate at a frequency related to their diameter. The image transducer is operated in a pulse-echo mode at a controllable repetition rate that transmits bursts of high-frequency ultrasonic signal to the measurement volume in which bubbles may be detected and then receives the echo. From the echo or received signal, a beat signal related to the repetition rate may be extracted and used to indicate the presence or absence of a resonant bubble. In a preferred embodiment, software control maintains the beat signal at a preselected frequency while varying the pump transducer frequency to excite bubbles of different diameters to resonate depending on the range of bubble diameters selected for investigation.

Kline-Schoder, Robert↗

Resonant power processors. I - State plane analysis

State-plane techniques in conjunction with piecewise-linear analysis is employed to study the steady-state and transient characteristics of a series resonant converter. With the direct viewing of the resonant tank energy and the device switching instants, the state portrayal provides unique insights into the complex behavior of the converter. Operation of the converter under both continuous and discontinuous current modes and at frequencies both below and above resonant frequency are discussed.

Oruganti, R.↗

Frequency‐Locked Wireless Multifunctional Surface Acoustic Wave Sensors

Abstract Surface acoustic waves (SAWs) have shown great potential for developing sensors for structural health monitoring (SHM) and lab‐on‐a‐chip (LOC) applications. Existing SAW sensors mainly rely on measuring the frequency shifts of high‐frequency (e.g., >0.1 GHz) resonance peaks. This study presents frequency‐locked wireless multifunctional SAW sensors that enable multiple wireless sensing functions, including strain sensing, temperature measurement, water presence detection, and vibration sensing. These sensors leverage SAW resonators on piezoelectric chips, inductive coupling‐based wireless power transmission, and, particularly, a frequency‐locked wireless sensing mechanism that works at low frequencies (e.g., <0.1 GHz). This mechanism locks the input frequency on the slope of a sensor's reflection spectrum and monitors the reflection signal's amplitude change induced by the changes of sensing parameters. The proof‐of‐concept experiments show that these wireless sensors can operate in a low‐power active mode for on‐demand wireless strain measurement, temperature sensing, and water presence detection. Moreover, these sensors can operate in a power‐free passive mode for vibration sensing, with results that agree well with laser vibrometer measurements. It is anticipated that the designs and mechanisms of the frequency‐locked wireless SAW sensors will inspire researchers to develop future wireless multifunctional sensors for SHM and LOC applications.

Bo, Luyu↗

Reducing Field Distortion in Magnetic Resonance Imaging

A concept for a magnetic resonance imaging (MRI) system that would utilize a relatively weak magnetic field provides for several design features that differ significantly from the corresponding features of conventional MRI systems. Notable among these features are a magnetic-field configuration that reduces (relative to the conventional configuration) distortion and blurring of the image, the use of a superconducting quantum interference device (SQUID) magnetometer as the detector, and an imaging procedure suited for the unconventional field configuration and sensor. In a typical application of MRI, a radio-frequency pulse is used to excite precession of the magnetic moments of protons in an applied magnetic field, and the decaying precession is detected for a short time following the pulse. The precession occurs at a resonance frequency proportional to the strengths of the magnetic field and the proton magnetic moment. The magnetic field is configured to vary with position in a known way; hence, by virtue of the aforesaid proportionality, the resonance frequency varies with position in a known way. In other words, position is encoded as resonance frequency. MRI using magnetic fields weaker than those of conventional MRI offers several advantages, including cheaper and smaller equipment, greater compatibility with metallic objects, and higher image quality because of low susceptibility distortion and enhanced spin-lattice-relaxation- time contrast. SQUID MRI is being developed into a practical MRI method for applied magnetic flux densities of the order of only 100 T

Eom, Byeong Ho↗

Tidal Circularization of Binaries by Resonance Locking. I. The Importance of the Pre-main Sequence

Although tidal dissipation in binary stars has been studied for over a century, theoretical predictions have yet to match the observed properties of binary populations. This work quantitatively examines the recent proposal of tidal circularization by resonance locking, where tidal dissipation arises from resonances between the star’s natural oscillation frequencies and harmonics of the orbital frequency, and where resonances are “locked” for an extended period of time due to concurrent stellar evolution. We focus on tidal resonances with axi-symmetric gravity modes, and examine binaries with primary masses from one to two solar masses. We find that orbital evolution via resonance locking occurs primarily during the star’s pre-main-sequence phase, with the main-sequence phase contributing negligibly. Resonance locking, ignoring nonlinearity, can circularize binaries with peri-center distances out to ∼10 stellar radii, corresponding to circular periods of ∼4–6 days. However, we find resonantly excited gravity modes will become nonlinear in stellar cores, which prevents them from reaching their full, linear amplitudes. We estimate that such a “saturated resonance lock” reduces the circularization period by about a third, but resonance locking remains much more effective than the cumulative actions of equilibrium tides. In a companion paper, we examine recent binary data to compare against theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modeling of multi-rotor torsional vibrations in rotating machinery using substructuring

The application of FEM modeling techniques to the analysis of torsional vibrations in complex rotating systems is described and demonstrated, summarizing results reported by Soares (1985). A substructuring approach is used for determination of torsional natural frequencies and resonant-mode shapes, steady-state frequency-sweep analysis, identification of dynamically unstable speed ranges, and characterization of transient linear and nonlinear systems. Results for several sample problems are presented in diagrams, graphs, and tables. STORV, a computer code based on this approach, is in use as a preliminary design tool for drive-train torsional analysis in the High Altitude Wind Tunnel at NASA Lewis.

Soares, Fola R.↗

A Method of Moments Wide Band Adaptive Rational Interpolation Method for High-Quality Factor Resonant Cavities

A new adaptive rational interpolation method is proposed to obtain the wideband frequency response of a resonant cavity simulated with the method of moments (MoM). This interpolation method uses both the Loewner matrix to construct a rational expression for the solution vector of MoM’s matrix system and an error estimator generated by the solution vectors and their derivatives. This error estimator is implemented in the adaptive procedure to gain a minimum set of frequencies and solution vectors required in the interpolation. The resulting set of frequencies and solution vectors is applied to interpolate other system variables, such as shielding effectiveness and input impedance. Here numerical results of a slotted cylindrical cavity supporting high-quality factor resonances are presented, showing that the new rational interpolation method is accurate and efficient in interpolating the complicated resonant response of the solution vector functions.

42 ENGINEERING↗

Influence of the Biasing Scheme on the Performance of Au/SrTiO3/LaAlO3 Thin Film Conductor/Ferroelectric Tunable Ring Resonators

The performance of gold/SrTio3 /LaAlO3 conductor/ferroelectric/dielectric side-coupled, tunable ring resonators at K-band frequencies is presented. The tunability of these rings arises from the sensitivity of the relative dielectric constant (Er) of SrTiO 3 to changes in temperature and dc electric fields (E). We observed that the change in F-, which takes place by biasing the ring up to 450 V alters the effective dielectric constant (e-eff) of the circuit resulting in a 3k resonant frequency shift of nearly 12 % at 77 K. By applying a separate dc bias between the microstrip line and the ring, one can optimize their coupling to obtain bandstop resonators with unloaded quality factors (Q(sub o)) as high as 12,000. The 31 resonance was tuned from 15.75 to 17.41 GHz while keeping Q. above 768 over this range. The relevance of these results for practical microwave components will be discussed.

VanKeuls, F. W.↗

Model support roll balance and roll coupling

The design concepts of two specialized wind tunnel model support mechanisms are described. The forced oscillation roll balance mechanism was designed to meet the specific requirement to measure aerodynamic forces and moments to permit determination of the damping-in-roll parameters of winged configurations. A variable speed motor is used to oscillate the model by means of an offset crank. The oscillating motion is resisted by a torsion spring to provide a restoring torque and is attached to the section forward of the strain-gage balance. This spring action allows the model to be oscillated at a frequency for velocity resonance, whereby the mechanical spring and any aerodynamic spring balance. This spring action allows the model to be oscillated at a frequency for velocity resonance, whereby the mechanical spring and any aerodynamic spring balance out the model inertia. The only torque then required to oscillate the model at that particular frequency is equal to that due to aerodynamic damping. The second mechanism, a roll coupling for remotely rotating a model, was designed to invert or roll a model about its longitudinal axis when mounted for testing.

Sharpes, R. E.↗

Penetration through slots in cylindrical cavities with cavity modes overlapping with the first slot resonance

In this work, we analyze the coupling into a slotted cylindrical cavity operating at fundamental cavity modal frequencies overlapping with the slot’s first resonance frequency through an unmatched formulation that accounts for the slot’s absorption and radiation processes. The model is validated through full-wave simulations and experimental data. We then couple the unmatched formulation to a perturbation theory model to investigate an absorber within the cavity to reduce the interior field strength, also validated with full-wave simulations and experiments. These models are pivotal to understanding the physical processes involved in the electromagnetic penetration through slots, and may constitute design tools to mitigate electromagnetic interference effects within cavities.

42 ENGINEERING↗

A Method for In-Situ Q₀ Measurements of High-Quality SRF Resonators

Accelerator projects such as LCLS-II naturally require low-loss superconducting (SRF) cavities. Due to strong demand for improving intrinsic quality factor (Q₀), importance of accurate cavity characterization increases. We propose a method to measure Q₀ in situ for an SRF resonator installed in its cryogenic module and connected with a RF feed source via a fixed RF coupler. The method exploits measurements of a response for an SRF resonator fed by an amplitude-modulated signal. Such a signal can be synthesized as a beat-wave composed of two frequencies that are close to the resonant frequency. Analyzing the envelope of the reflected signal, one can find the difference in reflection for the chosen frequencies and use them to compute the intrinsic Q. We also develop the methodology to carry out measurements of Q₀ at the nominal cavity operating voltage. We verified our method in experiments with a room temperature copper resonator and with two SRF resonators including Fermilab’s 650 MHz cavity and JLab’s 1500 MHz cavity.

43 PARTICLE ACCELERATORS↗

A design procedure for the phase-controlled parallel-loaded resonant inverter

High-frequency-link power conversion and distribution based on a resonant inverter (RI) has been recently proposed. The design of several topologies is reviewed, and a simple approximate design procedure is developed for the phase-controlled parallel-loaded RI. This design procedure seeks to ensure the benefits of resonant conversion and is verified by data from a laboratory 2.5 kVA, 20-kHz converter. A simple phasor analysis is introduced as a useful approximation for design purposes. The load is considered to be a linear impedance (or an ac current sink). The design procedure is verified using a 2.5-kVA 20-kHz RI. Also obtained are predictable worst-case ratings for each component of the resonant tank circuit and the inverter switches. For a given load VA requirement, below-resonance operation is found to result in a significantly lower tank VA requirement. Under transient conditions such as load short-circuit, a reversal of the expected commutation sequence is possible.

King, Roger J.↗

Vibration Method for Tracking the Resonant Mode and Impedance of a Microwave Cavity

There has been a concerted effort to improve the microwave heating technique for processing materials at high temperature. Improved optimization of the energy transfer from a microwave source to the material being processed is required. A vibration technique is pre- sented to continuously maintain a mode resonance and impedance match between a constant frequency magnetron source and a resonant cavity.

microwave↗

Pseudo continuous wave instrument

Acoustic properties and their changes in a sample of liquid, gas, plasma or solid are measured by applying a variable frequency source to the sample by means of a transducer to produce sound waves within the sample. The application of the variable frequency source to the sample is periodically interrupted for a short duration. Means are connected to the transducer for receiving the resulting acoustic signals during the interruptions for producing a control signal indicative of a difference in the frequency of the output of the variable frequency source and the frequency of a mechanical resonant peak in the sample. The control signal is applied to the variable frequency source to maintain its output frequency at the frequency of the mechanical resonant peak. The change in frequency of the variable frequency source indicates the shift in frequency of the mechanical resonant peak and the amplitude of the acoustic signals indicates the attenuation of the acoustic signals in the sample.

Heyman, J. S.↗