Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pump systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

An assessment of the use of antimisting fuel in turbofan engines

The effects of antimisting kerosene on the performance of the components from the fuel system and the combustor of a JT8D aircraft engine were evaluated. The problems associated with antimisting kerosene were identified and the extent of shearing or degradation required to allow the engine components to achieve satisfactory operation were determined. The performance of the combustor was assessed in a high pressure facility and in an altitude relight/cold ignition facility. The performance of the fuel pump and control system was evaluated in an open loop simulation.

Fiorentino, A.↗

Optically pumped polarized 3 He ++ ion source development for RHIC/EIC

The proposed polarized 3 He ++ acceleration in RHIC and the future Electron-Ion Collider will require about 2×10 11 ions in the source pulse. A new technique had been proposed for production of high intensity polarized 3 He ++ ion beams. It is based on ionization and accumulation of the 3 He gas (polarized by metastability-exchange optical pumping and in the 5T high magnetic field) in the existing Electron Beam Ion Source (EBIS). A novel 3 He cryogenic purification and storage technique was developed to provide the required gas purity. An original gas refill and polarized 3 He gas injection to the EBIS long drift tubes, (which serves as the storage cell) were developed to ensure polarization preservation. An infrared laser system for optical pumping and polarization measurements in the high 3–5 T field has been developed. The 3 He polarization 80–85% (and sufficiently long ~30 min relaxation time) was obtained in the “open” cell configuration with refilling valve tube inlet and isolation valve closed. The development of the spin-rotator and 3 He 4 He absolute nuclear polarimeter at 6 MeV 3 He ++ beam energy is also presented here in this work.

43 PARTICLE ACCELERATORS↗

Pump-probe X-ray Diffraction Technique for Irreversible Phase Change Materials

We have developed a pump-probe X-ray diffraction measurement system for a sample with irreversible reaction at BL40XU in the SPring-8. The system mainly consists of a time-resolved measurement system, a sample disk rotation system, and an X-ray microbeam system. The time-resolved measurement system gives time resolution of 50 ps in laser-pump and X-ray probe method. A sample disk rotation system for repetitive measurements was made to give a virgin sample for every measurement. The number of repetitions for one sample disk was increased by using the X-ray microbeam technique. To keep the overlap of the X-ray microbeam and the laser beam on the sample surface during the disk rotation, the sample disk rotation system was constructed by a low-eccentric spindle motor. By using this system, the pump-probe X-ray diffraction measurement was demonstrated for a crystallization process of a DVD material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Computer Modeling VRF Heat Pumps in Commercial Buildings using EnergyPlus

Variable Refrigerant Flow (VRF) heat pumps are increasingly used in commercial buildings in the United States. Monitored energy use of field installations have shown, in some cases, savings exceeding 30% compared to conventional heating, ventilating, and air-conditioning (HVAC) systems. A simulation study was conducted to identify the installation or operational characteristics that lead to energy savings for VRF systems. The study used the Department of Energy EnergyPlus? building simulation software and four reference building models. Computer simulations were performed in eight U.S. climate zones. The baseline reference HVAC system incorporated packaged single-zone direct-expansion cooling with gas heating (PSZ-AC) or variable-air-volume systems (VAV with reheat). An alternate baseline HVAC system using a heat pump (PSZ-HP) was included for some buildings to directly compare gas and electric heating results. These baseline systems were compared to a VRF heat pump model to identify differences in energy use. VRF systems combine multiple indoor units with one or more outdoor unit(s). These systems move refrigerant between the outdoor and indoor units which eliminates the need for duct work in most cases. Since many applications install duct work in unconditioned spaces, this leads to installation differences between VRF systems and conventional HVAC systems. To characterize installation differences, a duct heat gain model was included to identify the energy impacts of installing ducts in unconditioned spaces. The configuration of variable refrigerant flow heat pumps will ultimately eliminate or significantly reduce energy use due to duct heat transfer. Fan energy is also studied to identify savings associated with non-ducted VRF terminal units. VRF systems incorporate a variable-speed compressor which may lead to operational differences compared to single-speed compression systems. To characterize operational differences, the computer model performance curves used to simulate cooling operation are also evaluated. The information in this paper is intended to provide a relative difference in system energy use and compare various installation practices that can impact performance. Comparative results of VRF versus conventional HVAC systems include energy use differences due to duct location, differences in fan energy when ducts are eliminated, and differences associated with electric versus fossil fuel type heating systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The enhanced capillary pumped loop flight experiment, a prototype of the EOS platform thermal control system

The CAPL shuttle flight experiment will provide micro-gravity verification of the prototype capillary pumped loop (CPL) thermal control system for EOS. The design of the experiment is discussed with particular emphasis on the new technology areas in ammonia two-phase reservoir design and heat pipe heat exchanger development. The thermal and hydrodynamic analysis techniques and results are also presented, including pressure losses, fluid flow, and on-orbit heat rejection capability. CAPL experiment results will be presented after the flight, currently planned for 1993.

Butler, D.↗

Strong and weak coupling of two coupled qubits

I investigate the dynamics and power spectrum of two coupled qubits (two-level systems) under incoherent continuous pump and dissipation. New regimes of strong coupling are identified, which are due to additional paths of coherence flow in the system. Dressed states are reconstructed even in the regime of strong decoherence. The results are analytical and offer an exact description of strong coupling in the presence of pumping and decay in a nontrivial (nonlinear) system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

AUTOMATED WATER LEVEL MEASUREMENTS IN SMALL-DIAMETER AQUIFER TUBES

Groundwater contaminated with hexavalent chromium, strontium-90, and uranium discharges into the Columbia River along approximately 16 km (10 mi) of the shoreline. Various treatment systems have and will continue to be implemented to eliminate the impact of Hanford Site contamination to the river. To optimize the various remediation strategies, it is important to understand interactions between groundwater and the surface water of the Columbia River. An automated system to record water levels in aquifer sampling tubes installed in the hyporheic zone was designed and tested to (1) gain a more complete understanding of groundwater/river water interactions based on gaining and losing conditions ofthe Columbia River, (2) record and interpret data for consistent and defensible groundwater/surface water conceptual models that may be used to better predict subsurface contaminant fate and transport, and (3) evaluate the hydrodynamic influence of extraction wells in an expanded pump-and-treat system to optimize the treatment system. A system to measure water levels in small-diameter aquifer tubes was designed and tested in the laboratory and field. The system was configured to allow manual measurements to periodically calibrate the instrument and to permit aquifer tube sampling without removing the transducer tube. Manual measurements were collected with an e-tape designed and fabricated especially for this test. Results indicate that the transducer system accurately records groundwater levels in aquifer tubes. These data are being used to refine the conceptual and numeric models to better understand interactions in the hyporheic zone of the Columbia River and the adjacent river water and groundwater, and changes in hydrochemistry relative to groundwater flux as river water recharges the aquifer and then drains back out in response to changes in the river level.

54 ENVIRONMENTAL SCIENCES↗

Measured Whole-House Performance of TaC Studios Test Home

As part of the NAHB Research Center Industry Partnership, Southface partnered with TaC Studios, an Atlanta-based architecture firm specializing in residential and light commercial design, on the construction of a new test home in Atlanta, GA in the mixed humid climate. This home serves as a residence and home office for the firm's owners, as well as a demonstration of their design approach topotential and current clients. Southface believes the home demonstrates current best practices for the mixed-humid climate, including a building envelope featuring advanced air sealing details and low density spray foam insulation, glazing that exceeds ENERGY STAR requirements, and a high performance heating and cooling system. Construction quality and execution was a high priority for TaCStudios and was ensured by a third party review process. Post-construction testing showed that the project met stated goals for envelope performance, an air infiltration rate of 2.15 ACH50. The homeowners wished to further validate whole house energy savings through the project's involvement with Building America and this long-term monitoring effort. As a Building America test home, this homewas evaluated to detail whole house energy use, end use loads, and the efficiency and operation of the ground source heat pump and associated systems. Given that the home includes many non-typical end use loads including a home office, pool, landscape water feature, and other luxury features not accounted for in Building America modeling tools, these end uses were separately monitored todetermine their impact on overall energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measured Whole-House Performance of TaC Studios Test Home

As part of the NAHB Research Center Industry Partnership, Southface partnered with TaC Studios, an Atlanta-based architecture firm specializing in residential and light commercial design, on the construction of a new test home in Atlanta, GA, in the mixed humid climate. This home serves as a residence and home office for the firm's owners, as well as a demonstration of their design approach to potential and current clients. Southface believes the home demonstrates current best practices for the mixed-humid climate, including a building envelope featuring advanced air sealing details and low density spray foam insulation, glazing that exceeds ENERGY STAR requirements, and a high performance heating and cooling system. Construction quality and execution was a high priority for TaC Studios and was ensured by a third party review process. Post-construction testing showed that the project met stated goals for envelope performance, an air infiltration rate of 2.15 ACH50. The homeowners wished to further validate whole house energy savings through the project's involvement with Building America and this long-term monitoring effort. As a Building America test home, this home was evaluated to detail whole house energy use, end use loads, and the efficiency and operation of the ground source heat pump and associated systems. Given that the home includes many non-typical end use loads including a home office, pool, landscape water feature, and other luxury features not accounted for in Building America modeling tools, these end uses were separately monitored to determine their impact on overall energy consumption.

(team name)↗

Combined laser ultrasonics, laser heating, and Raman scattering in diamond anvil cell system

Here, we developed a multi-functional in situ measurement system under high pressure equipped with a laser ultrasonics (LU) system, Raman device, and laser heating system (LU-LH) in a diamond anvil cell (DAC). The system consists of four components: (1) a LU-DAC system (probe and pump lasers, photodetector, and oscilloscope) and DAC; (2) a fiber laser, which is designed to allow precise control of the total power in the range from 2 to 100 W by changing the diode current, for heating samples; (3) a spectrometer for measuring the temperature of the sample (using black body radiation), fluorescence spectrum (spectrum of the ruby for pressure measurement), and Raman scattering measurements inside a DAC under high pressure and high temperature (HPHT) conditions; and (4) an optical system to focus laser beams on the sample and image it in the DAC. The system is unique and allows us to do the following: (a) measure the shear and longitudinal velocities of non-transparent materials under HPHT; (b) measure temperature in a DAC under HPHT conditions using Planck’s law; (c) measure pressure in a DAC using a Raman signal; and (d) measure acoustical properties of small flat specimens removed from the DAC after HPHT treatment. In this report, we demonstrate that the LU-LH-DAC system allows measurements of velocities of the skimming waves in iron at 2580 K and 22 GPa.

47 OTHER INSTRUMENTATION↗

Laser spark plug numerical design process with experimental validation

This work reports the numerical modeling design procedure for a miniaturized laser spark plug. In previous work both side pumped and end pumped laser spark plugs were empirically designed and tested. Experimental data from the previous laser spark plug development cycles is compared to the output predicted by a known set of rate equations. The rate equations are used to develop interrelated inter cavity time dependent waveforms that are then used to identify key variables. These variables are then input to a set of secondary equations for determining the output pulse energy, output power, and output pulse width of the simulated laser system. The physical meaning and the operation of the rate equations is explained in detail. This paper concentrates on the process and decision points needed to successfully design a solid state passively Q-switched laser system, either side pumped or end pumped, that produces the appropriate output needed for use as a laser spark plug for internal combustion engines.

58 GEOSCIENCES↗

Building America Case Study: Performance and Costs of Ductless Heat Pumps in Marine Climate High-Performance Homes: Habitat for Humanity -- The Woods, Tacoma, Washington

The Woods is a Habitat for Humanity (HFH) community of ENERGY STAR Homes (c) Northwest (ESHNW)-certified homes located in the marine climate of Tacoma/Pierce County, Washington. This research report builds on an earlier preliminary draft 2014 BA report, and includes significant billing analysis and cost effectiveness research from a collaborative, ongoing Ductless Heat Pump (DHP) research effort for Tacoma Public Utilities (TPU) and Bonneville Power Administration (BPA). This report focuses on the results of field testing, modeling, and monitoring of ductless mini-split heat pump hybrid heating systems in seven homes built and first occupied at various times between September 2013 and October 2014. The report also provides WSU documentation of high-performance home observations, lessons learned, and stakeholder recommendations for builders of affordable high-performance housing such as HFH.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design-Point Techno-Economics of Brayton Cycle PTES for Combined Heat and Power

Pumped thermal energy storage (PTES) systems are grid batteries that use heat pumps to create both hot and cold thermal energy stores when there is excess electricity and then use a power cycle to convert the thermal energy into electricity when there is demand for electricity. In normal operation, Joule–Brayton PTES discharges low-grade heat at temperatures useful for thermal energy consumers like district and industrial heating. Furthermore, PTES designs, like conventional combined heat and power (CHP) technology, can be modified to sacrifice some round-trip efficiency (RTE) to increase the temperature of heat rejection. Here, this paper uses design-point performance and cost models that provide a detailed understanding of the efficiency and cost tradeoffs of rejecting heat at various temperatures in ideal-gas Brayton PTES configurations. First, we keep the heat rejection in its nominal location in the PTES system: in the discharge cycle after the low-pressure exit of the recuperator before the cold-storage heat exchanger. Next, we move the heat rejection to the discharge turbine exit. We define design-point metrics that isolate both the cost and performance penalty associated with the hotter heat rejection and attribute it exclusively to the heat economic metrics. Finally, we estimate the performance of electric heater technology to generate heat at equivalent temperatures. We find that the levelized cost of heat (LCOH), including the cost of thermal energy storage (TES) buffering the PTES and heat off-taker, compares favorably versus electric technologies and is less than the cost of natural gas for low temperature scenarios and competitive with the cost of natural gas in some regions of the contiguous U.S. in high temperature scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design-Point Techno-Economics of Brayton Cycle PTES for Combined Heat and Power

Pumped thermal energy storage (PTES) systems are grid batteries that use heat pumps to create both hot and cold thermal energy stores when there is excess electricity and then use a power cycle to convert the thermal energy into electricity when there is demand for electricity. In normal operation, Joule-Brayton PTES discharges low-grade heat at temperatures useful for thermal energy consumers like district and industrial heating. Furthermore, PTES designs, like conventional combined heat and power (CHP) technology, can be modified to sacrifice some round-trip efficiency RTE to increase the temperature of heat rejection. This paper uses design-point performance and cost models that provide a detailed understanding of the efficiency and cost trade-offs of rejecting heat at various temperatures in ideal-gas Brayton PTES configurations. First, we keep the heat rejection in its nominal location in the PTES system: in the discharge cycle after the low-pressure exit of the recuperator before the cold-storage heat exchanger. Next, we move the heat rejection to the discharge turbine exit. We define design-point metrics that isolate both the cost and performance penalty associated with the hotter heat rejection and attribute it exclusively to the heat economic metrics. Finally, we estimate the performance of electric heater technology to generate heat at equivalent temperatures. We find that the levelized cost of heat, including the cost of thermal energy storage (TES) buffering the PTES and heat off-taker, compares favorable versus electric technologies and is less than the cost of natural gas for low temperature scenarios and competitive with the cost of natural gas in some regions of the contiguous United States in high temperature scenarios.

CHP↗

Renovation of Thermal Vacuum Chambers at Idaho National Laboratory (INL) for Testing of Radioisotope Power Systems (RPS)

The Radioisotope Power Systems (RPS) program at Idaho National Laboratory (INL) fuels and performs environmental testing of RPS in support of National Aeronautics and Space Administration (NASA) missions. Recently the programs’ thermal vacuum chambers, housed within INL’s Space and Security Power Systems Facility (SSPSF), underwent successful renovations to improve functional capabilities and system control in support of customer missions. Thermal vacuum system renovations focused primarily on three core functions. The first focus area was integration of semi-automated Programmable Logic Controllers (PLC) to enhance operational feedback and process control. This included the use of numerically controlled vacuum valves and integration of real time feedback from process pressure transducers. Improvements to the system high vacuum pumping technology was the second priority focus. Legacy diffusion pumps were replaced with turbo-molecular and cryogenic pumps to help mitigate the possibility of back streaming diffusion pump oil onto the surface of the test article or radiative cooling surfaces located within the chambers. The third and final core function involved meeting emergent customer thermal requirements. This led to retro-fitting one of the vacuum chambers with a cryogenically cooled Thermal Conditioning Unit (TCU) and thermal shrouds. The TCU utilizes gaseous nitrogen to heat or cool a cylindrical shroud to maintain a set temperature with a programmable range of -I85 °C to I00 °C. With the successful completion of RPS acceptance testing, the newly renovated thermal vacuum chamber systems are operational and better equipped to support testing of Radioisotope Power Systems for space exploration missions.

42 ENGINEERING↗

Renovation of Thermal Vacuum Chambers at Idaho National Laboratory for Testing of Radioisotope Power Systems

The Radioisotope Power Systems (RPS) program at Idaho National Laboratory (INL) fuels and performs environmental testing of RPS in support of National Aeronautics and Space Administration (NASA) missions. Recently the programs’ thermal vacuum chambers, housed within INL’s Space and Security Power Systems Facility (SSPSF), underwent successful renovations to improve functional capabilities and system control in support of customer missions. Thermal vacuum system renovations focused primarily on three core functions. The first focus area was integration of semi-automated Programmable Logic Controllers (PLC) to enhance operational feedback and process control. This included the use of numerically controlled vacuum valves and integration of real time feedback from process pressure transducers. Improvements to the system high vacuum pumping technology was the second priority focus. Legacy diffusion pumps were replaced with turbo-molecular and cryogenic pumps to help mitigate the possibility of back streaming diffusion pump oil onto the surface of the test article or radiative cooling surfaces located within the chambers. The third and final core function involved meeting emergent customer thermal requirements. This led to retro-fitting one of the vacuum chambers with a cryogenically cooled Thermal Conditioning Unit (TCU) and thermal shrouds. The TCU utilizes gaseous nitrogen to heat or cool a cylindrical shroud to maintain a set temperature with a programmable range of -I85 °C to I00 °C. With the successful completion of RPS acceptance testing, the newly renovated thermal vacuum chamber systems are operational and better equipped to support testing of Radioisotope Power Systems for space exploration missions.

42 ENGINEERING↗

Renovation of Thermal Vacuum Chambers at Idaho National Laboratory (INL) for Testing of Radioisotope Power Systems (RPS)

The Radioisotope Power Systems (RPS) program at Idaho National Laboratory (INL) fuels and performs environmental testing of RPS in support of National Aeronautics and Space Administration (NASA) missions. Recently the programs’ thermal vacuum chambers, housed within INL’s Space and Security Power Systems Facility (SSPSF), underwent successful renovations to improve functional capabilities and system control in support of customer missions. Thermal vacuum system renovations focused primarily on three core functions. The first focus area was integration of semi-automated Programmable Logic Controllers (PLC) to enhance operational feedback and process control. This included the use of numerically controlled vacuum valves and integration of real time feedback from process pressure transducers. Improvements to the system high vacuum pumping technology was the second priority focus. Legacy diffusion pumps were replaced with turbo-molecular and cryogenic pumps to help mitigate the possibility of back streaming diffusion pump oil onto the surface of the test article or radiative cooling surfaces located within the chambers. The third and final core function involved meeting emergent customer thermal requirements. This led to retro-fitting one of the vacuum chambers with a cryogenically cooled Thermal Conditioning Unit (TCU) and thermal shrouds. The TCU utilizes gaseous nitrogen to heat or cool a cylindrical shroud to maintain a set temperature with a programmable range of -I85 °C to I00 °C. With the successful completion of RPS acceptance testing, the newly renovated thermal vacuum chamber systems are operational and better equipped to support testing of Radioisotope Power Systems for space exploration missions.

42 ENGINEERING↗

Ionization-Assisted Getter Pumping for Ultra-Stable Trapped Ion Frequency Standards

A method eliminates (or recovers from) residual methane buildup in getter-pumped atomic frequency standard systems by applying ionizing assistance. Ultra-high stability trapped ion frequency standards for applications requiring very high reliability, and/or low power and mass (both for ground-based and space-based platforms) benefit from using sealed vacuum systems. These systems require careful material selection and system processing (cleaning and high-temperature bake-out). Even under the most careful preparation, residual hydrogen outgassing from vacuum chamber walls typically limits the base pressure. Non-evaporable getter pumps (NEGs) provide a convenient pumping option for sealed systems because of low mass and volume, and no power once activated. An ion gauge in conjunction with a NEG can be used to provide a low mass, low-power method for avoiding the deleterious effects of methane buildup in high-performance frequency standard vacuum systems.

Tjoelker, Robert L.↗