Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power system event”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Enhanced Component Performance Study: Turbine-Driven Pumps 1998-2020

This report presents an enhanced performance evaluation of turbine-driven pumps (TDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2020 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The TDP failure modes considered for standby systems are fail to start (FTS), fail to run (FTR) for one hour of operation (FTR≤1H), FTR after one hour of operation (FTR>1H), and for normally running systems FTS and FTR. An eight-hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period. No increasing trends were identified for TDPs for the most recent 10-year period: The following decreasing trends were identified for TDPs for the most recent 10-year period: • Standby TDP FTR>1H failure rate • Standby TDP unavailability • Standby MDP total unreliability (8-hour mission) • Standby TDP frequency of FTR>1H events (failures per reactor year) • Normally running TDP frequency of start demands (demands per reactor year) • Normally running TDP frequency of run hours (hours per reactor year).

99 GENERAL AND MISCELLANEOUS↗

Thermal and electric multidomain dynamic model for integration of power grid distribution with behind-the-meter devices

As renewable energy sources like solar and wind power become more integrated into the grid, coordinated control of behind-the-meter devices is crucial for enhancing grid flexibility and reliability and for meeting cost targets, with standardized models being developed to support this transition. The increasing flexibility and uncertainty of integrated renewable energy grids, along with interactions between various subsystems, make traditional steady-state modeling insufficient to capture transient and dynamic behaviors. Current models (e.g., composite load and battery equivalent models) focus on thermodynamic or electrical characteristics but overlook critical electromechanical interactions. This limits the ability to share performance information for grid services and hampers fast dynamic simulations. In addition, motor stalling is usually triggered by a fault event and attributed to the characteristics of the mechanical torque of the motor, resulting in absorption of a large amount of reactive power during the stalling period. Further, this significant withdrawal of reactive power will deteriorate the dynamic voltage stability of power grids and cause delayed voltage recovery. Therefore, an in-depth modeling of the thermodynamics or mechanical torque is essential to study the impacts of the realistic torque characteristics of those behind-the-meter devices on power system voltage stability. This study developed a dynamic multidomain model for building HVAC systems, such as air-source heat pumps, to simulate their thermal and electrical responses to grid transients. The model can accurately predict power metrics with a mean absolute percentage error of 10%, by validating against with power system computer-aided design performance data. Case studies demonstrate the model capability of capturing the transient response to sudden voltage changes, rapid load fluctuations, and system shutdowns respectively. During a sudden voltage drop (30% for 0.1s), a fully loaded heat pump’s motor speed dropped, continued declining, and shut down after 3.6s, with severe power oscillations and a torque spike. A partially loaded unit experienced temporary oscillations but stabilized. Under higher building loads, compressor speed increased from 64% to 100%, with power and torque rising before stabilizing. In safety-triggered shutdowns, power decreased after minor fluctuations, and torque briefly spiked before dropping to zero.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Unified Metric for Fast Frequency Response in Low-Inertia Power Systems

Future power systems with more inverter-based resources (IBRs), will be vulnerable to frequency decline contingencies. Fast frequency response (FFR) provided by IBRs is a good candidate to arrest frequency excursions. Diverse types of FFR have been proposed, and some have been deployed in our power systems. Without a unified quantification of FFR, it is hard for the grid operators to compare and fully leverage the FFR capabilities of IBRs. This work introduces a potential unified metric that quantifies two key characteristics of FFR and describes its application to three prevailing FFR types. We then use metric-to-frequency mapping to validate the accuracy of the metric in predicting the impact of a given FFR on the trajectory of a frequency event. The results show that the proposed metric is simple yet accurately captures the ability of diverse forms of FFR to improve system frequency dynamics.

effective inertia↗

Enabling Realistic Communications Evaluations for ADMS

Increasing penetration levels of inverter-based distributed energy resources (DERs) in distribution systems are creating challenges in system operation. Currently, wired or proprietary wireless communications are used by advanced distribution management systems (ADMS) to detect the state of the system and control the DERs for optimal operation. Wireless communications are an alternative solution that can enable connectivity between the dispersed assets used in distribution system applications. As demand for the seamless integration of distributed energy resources (DERs) continues to increase, proper networking and communications systems are becoming important to support the DER infrastructure. This report summarizes validation of a private wireless LTE network in a laboratory environment. The purpose of this work is to 1) demonstrate the effectiveness of private wireless LTE communication for grid applications and 2) provide a means of evaluating latency and overall performance of wireless communication in grid applications. First, private wireless LTE communication was validated in a direct transfer trip relaying scenario as an example of one-way communications using grid equipment. This study provided a baseline understanding of the variation in latency for seven different kinds of wireless scenarios shown in Figure A below. As expected, weak (attenuated) wireless signal-based communication yielded the widest ranges in latency. When higher priority was set for the trip signal communication, this resulted in lower latency in communication timing. In the final phase of this project, the private wireless LTE network was validated using two-way communications in an advanced distribution management system (ADMS) testbed which was developed in the ESIF at NREL. The purpose of this was to study the impact of wireless communication on grid performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Harmonized Automatic Relay Mitigation of Nefarious Intentional Events (HARMONIE) - Special Protection Scheme (SPS)

The harmonized automatic relay mitigation of nefarious intentional events (HARMONIE) special protection scheme (SPS) was developed to provide adaptive, cyber-physical response to unpredictable disturbances in the electric grid. The HARMONIE-SPS methodology includes a machine learning classification framework that analyzes real time cyber-physical data and determines if the system is in normal conditions, cyber disturbance, physical disturbance, or cyber-physical disturbance. This classification then informs response, if needed and/or suitable, and included cyber-physical corrective actions. Beyond standard power system mitigations, a few novel approaches were developed that included a consensus algorithm-based relay voting scheme, an automated power system triggering condition and corrective action pairing algorithm, and a cyber traffic routing optimization algorithm. Both the classification and response techniques were tested within a newly integrated emulation environment composed of a real-time digital simulator (RTDS) and SCEPTRE™. This report details the HARMONIE-SPS methodology, highlighting both the classification and response techniques, and the subsequent testing results from the emulation environment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermal Spectrum Molten Salt-Fueled Reactor Reference Plant Model

This report details a fully coupled neutronics thermal hydraulics reference plant model for a thermal spectrum molten salt-fueled reactor. The Multiphysics model is developed on the Nuclear Regulatory Commission's Comprehensive Reactor Analysis Bundle available on the Idaho National Laboratory high-performance computer, which natively and seamlessly couples Griffin and Sam codes of the Multiphysics Object-Oriented Simulation Environment (MOOSE) based applications. Griffin provides the reactor physics capabilities, k-eigenvalue, delayed neutron precursor concentrations, and transient solutions for stationary and flowing fuels. Sam provides the solution of mass, momentum, and energy conservation equations of the whole system with a set of system components for one-dimensional single-phase flow. The neutronics feedback model relies primarily on fuel and moderator temperatures, fuel salt density, and delayed neutron precursors distributions. This report presents our results for the coupled steady state core and an unprotected loss of flow event. Although this model is prototypical regarding capabilities in the Comprehensive Reactor Analysis Bundle, its results are consistent with experimental data of the pump transient tests that were performed at zero power of the Molten Salt Reactor Experiment (MSRE).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Open Building Operating System: An Open-Source Grid Responsive Control Platform for Buildings

Grid-interactive efficient buildings (GEBs) with flexible loads are a promising method to decarbonize buildings, shift loads during peak hours, and lower energy use and electricity costs. Despite the promising benefits of GEBs, automation systems that manage flexible loads in response to energy prices or other grid signals are still uncommon in small and medium commercial buildings. Recent literature demonstrates such control solutions, but they often rely on custom integrations lacking the tools and drivers needed for scalability. To address these gaps, our team has created a fully open-source software stack capable of integrating heterogeneous flexible building loads and implementing integrated portable control applications called the Open Building Operating System (OpenBOS). The software can be deployed over existing control architecture with a small capital cost. OpenBOS leverages semantic models, which have been the subject of recent investigations to facilitate application portability. The use of semantic data reduces the labor and expense required to deploy and update smart control applications, increasing scalability. In this paper, the semantic modeling schema "Brick" was used, but the proposed approach can also be applied to ASHRAE standard 223P, when released. This paper describes the methodology and software components of OpenBOS and demonstrates its functionality with a rule-based demand flexibility control application configured using a semantic model. This application was tested at a real building in NY that uses a dual-fuel heating system made up of five ductless heat pump mini-splits and a central furnace serving a single zone. The demonstration reduced electricity costs at the site by 27%, demand during a shed event by 49%, and furnace usage by 35%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cryogenic on-orbit performance of the NASA Cosmic Background Explorer (COBE)

The initial thermal set-up and operation of the dewar for the COBE spacecraft are discussed, focusing on the helium vent system. During the initial cooldown of the dewar from 1.72 K to 1.41 K, short term temperature and pressure oscillations were observed in the porous plug and in the vent line. A detailed flow model describing these oscillations was developed. Attention is also given to the steady state operating mode for the instruments and the dewar, a comparison of the 'mission mode' temperature and power profile of the dewar with the predicted performance, the instrument and spacecraft events affecting the helium boil-off rate, and the methods for determining the helium flow rate and remaining mass measurements.

Volz, Stephen M.↗

Advanced Fuels Campaign Time-at-Temperature Irradiation Campaign and Post-Irradiation Examination Plan

With increasing per capita energy consumption and rapidly growing energy consumption predicted for data centers, the US faces challenges in meeting projected energy demands. The current administration is attempting to accelerate the deployment of new nuclear construction by providing significant investments in advanced nuclear and by modernizing regulatory approaches for the licensing new reactors. However, enabling extended power uprates (EPUs) for the current nuclear reactor fleet would provide a shorter-term solution to better calibrate near-term energy generation capacity to the ever-growing energy demands of the modern era. One pathway to achieve power uprates is to increase the operational window by reassessing fuel safety limits around anticipated transients. Existing light-water reactors (LWRs) utilize a targeted operational window with well-defined operational efficiencies, yet this window is also often bound by conservative safety limits that result in suboptimal operational performance. For example, the operation of the existing fleet is highly constrained by safeguards to operation related to anticipated operational occurrences (AOOs), which are moderate-frequency transients expected with a frequency greater than 0.01 per reactor-year. These AOOs include temperature excursions where the critical heat flux for the system is exceeded, resulting in a departure from nucleate boiling (DNB) at the cladding surface. This DNB event is a thermohydraulic condition that, with current conservative fuel safety limits, results in the fuel rods being classified as “failed,” meaning that the cladding may not be returned to service.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Megadrought: A Series of Unfortunate La Niña Events?

Megadroughts are multidecadal periods of aridity more persistent than most droughts during the instrumental period. Paleoclimate evidence suggests that megadroughts occur in many parts of the world, including North America, Central America, western Europe, eastern Asia, and northern Africa. It remains unclear to what extent such megadroughts require external forcing or whether they can arise from internal climate variability alone. A novel statistical–dynamical approach is used to evaluate the possibility that such events arise solely as a function of interannual tropical sea surface temperature (SST) variations. A statistical emulator of tropical SST variations is constructed by using an empirical moving-blocks bootstrap approach that randomly samples multiyear sequences of the observational SST record. This approach preserves the power spectrum, seasonal cycle, and spatial pattern of El Niño-Southern Oscillation (ENSO) but removes longer timescale fluctuations embedded in the observational record. These resampled SST anomalies are then used to force an atmospheric model (the Community Atmosphere Model Version 5). As megadroughts emerge in this run, they should, therefore, be solely a consequence of La Niña sequences combined with internal atmospheric variability and persistence driven by soil moisture storage and other land-surface processes. We indeed find that megadroughts in this simulation have an amplitude-duration rate that is generally indistinguishable from the rate documented in paleoclimate records of the western United States. Our findings support the idea that megadroughts may occur randomly when the unforced climate system evolves freely over a sufficiently long period of time, implying that an unforced unusual but statistically plausible series of La Niña events may be sufficient to generate megadrought.

54 ENVIRONMENTAL SCIENCES↗

Design and requirements of a hydrogen component reliability database (HyCReD)

Hydrogen technologies are expected to play a key role in the decarbonization of several sectors including energy storage and transportation. Rigorous investigation and quantification of the risk and reliability issues associated with hydrogen technologies will be critical to ensuring both their wider adoption and safe, economical operations. Quantitative risk assessment (QRA) is an important tool that has been used to enable the safe deployment of many engineering systems, including hydrogen fueling stations and hydrogen storage systems. However, QRA studies require reliability data which is currently lacking for expanding applications of hydrogen systems. Here, to address this gap, we present a new structure for a hydrogen component reliability database (HyCReD) that can be used to generate reliability data to be used in QRA, reliability, safety studies, maintenance planning, and more. Building on our previous work examining four major hydrogen safety data collection tools (West et al., 2022) [1], our approach in this work was to consult scientific literature on reliability data collection as well as a number of existing reliability engineering databases in the oil & gas, chemical processing, and nuclear power plant sectors. The evaluation of these databases led to identifying best practices to be implemented in a data collection framework for a hydrogen component reliability database. Based on these best practices, a set of 24 requirements for the proposed database are presented, covering its characteristics and the types of data to be collected. We define the structure of the HyCReD database and 25 data elements to be collected, spanning system description, failure, shutdown, or near-miss events, and maintenance events. The data elements are then defined according to international standards used in the safety and reliability practice and potential choice lists are provided for each field. Since this database is being piloted for hydrogen fueling stations, a generic station component hierarchy developed by West (2021) [2] is used to standardize system data. Finally, we demonstrate populating the database with information extracted from five narrative reports on hydrogen fueling station incidents.

08 HYDROGEN↗

Behavior of Multiple PV Plants in Future Power Grids During Events

As the integration of multiple photovoltaic (PV) plants into power grids grows, the dynamic response of each plant and their interactions during transient events demands a deeper understanding. In this paper, the dynamic behavior of multiple PV plants connected to future power grids is comprehensively explored using site-specific high-fidelity electromagnetic transient (EMT) PV plant models and generic high-fidelity EMT PV plant models. This research demonstrates the need to employ multiple high-fidelity EMT PV plant models to understand the intricate interactions between multiple PV plants during grid events. These models, developed in Fortran within the PSCAD environment, encompass a range of operational scenarios and plant configurations, offering invaluable insights crucial for future system planning with multiple PV plants to enhance grid stability.

Marthi, Phani Ratna Vanamali [ORNL] (ORCID:0000000↗

An Alternative Timing and Synchronization Approach for Situational Awareness and Predictive Analytics

Accurate and synchronized timing information is required by power system operators for controlling the grid infrastructure (relays, Phasor Measurement Units (PMUs), etc.) and determining asset positions. Satellite-based global positioning system (GPS) is the primary source of timing information. However, GPS disruptions today (both intentional and unintentional) can significantly compromise the reliability and security of our electric grids. A robust alternate source for accurate timing is critical to serve both as a deterrent against malicious attacks and as a redundant system in enhancing the resilience against extreme events that could disrupt the GPS network. To achieve this, we rely on the highly accurate, terrestrial atomic clock-based network for alternative timing and synchronization. In this paper, we discuss an experimental setup for an alternative timing approach. The data obtained from this experimental setup is continuously monitored and analyzed using various time deviation metrics. We also use these metrics to compute deviations of our clock with respect to the National Institute of Standards and Technologys (NIST) GPS data. The results obtained from these metric computations are elaborately discussed. Finally, we discuss the integration of the procedures involved, like real-time data ingestion, metric computation, and result visualization, in a novel microservices-based architecture for situational awareness.

Chinthavali, Supriya↗

Mitigation of Motor Stalling and FIDVR via Energy Storage Systems with Temporal Logic Specifications

The fault-induced delayed voltage recovery (FIDVR) phenomenon has been very common from the distribution system through the transmission system. It causes a delay on recovering significantly depressed local voltage after the fault is cleared, and it can also lead to more widespread cascading system failures. Mitigating this event with current control approaches is challenging and becoming a crucial issue. Here, a model predictive control-based strategy employing signal temporal logic specifications is proposed to help mitigate FIDVR. To this end, it investigates and extends a dynamic performance model allowing analytic insights into the system-wide impact of motor stalling and FIDVR. The proposed controller provides richer descriptions of voltage specifications addressing both magnitude and time simultaneously. We consider different control specifications with reactive power support from energy storage systems to prevent the voltage during/after the fault from dropping too low, and reduce the delay time of voltage recovery. The simulation results conducted with the IEEE 57 bus test network validate the proposed method and demonstrate the effectiveness of the mitigation strategy on FIDVR.

25 ENERGY STORAGE↗

A Guide for Improved Resource Adequacy Assessments in Evolving Power Systems: Institutional and Technical Dimensions

This paper identifies and evaluates issues in traditional resource adequacy (RA) assessment practices, and how adjusting these practices may affect and depend on existing institutional arrangements for planning and procurement. The paper proposes a technical-institutional roadmap that would allow regulators in vertically-integrated jurisdictions and system planners and operators in restructured jurisdictions to revise RA practices across a range of components. First, we compile a critical review of current RA assessment practices based on (1) interviews with RA practitioners and (2) a review of recent technical literature. We find that (i) RA may need to expand beyond capacity adequacy to ensure energy adequacy – relevant for energy-limited resources such as storage – and potentially some form of ancillary service adequacy (e.g. enough ramping-up and ramping-down capability in the system); (ii) chronological hourly simulations for all hours in the year are the current best practice; (iii) metrics and models used do not reflect economic criteria in system operation and loss of load; and (iv) there is a need to improve representation of weather dependencies and weather data. Second, we review planning and RA reports for several private and public entities that plan generation and/or transmission infrastructure in the continental U.S. to look for existing practices involving resilience assessments. We find no systematic treatment of the costs of extreme weather and other hazards, the benefits of resilience, and resilience metrics in planning analyses and no systematic treatment of resilience metrics, methods, and outcomes for resource adequacy purposes. Third, we create a technical framework for probabilistic RA assessment and use it to study how key choices about how to model power system operations affect the values that are obtained for RA metrics. We find that (i) non-economic dispatch schemes that ignore economic objectives can lead to accurate RA assessments when coordinated with detailed operational strategies; (ii) multi-year data is critical to capture a wide variety of system conditions; (iii) not incorporating transmission limits into RA assessment could lead to substantial underestimation of traditional “expected value” RA metrics; and (iv) new RA metrics that capture event-specific shortfall characteristics should be used as supplements to traditional metrics. Finally, we examine RA assessments and use this information to propose a guide of evolving industry standards for resource adequacy assessments in resource planning and transmission planning. We report minimum, best, and frontier practices for temporal resolution of assessments, metrics and targets, weather data, load forecasting, characterization of variable renewable resources, characterization of transmission and market transactions, RA modeling and integration with planning processes, and capacity accreditation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

OGLE-2017-BLG-1434Lb: Confirmation of a Cold Super-Earth Using Keck Adaptive Optics

The microlensing event OGLE-2017-BLG-1434 features a cold super-Earth planet that is 1 of 11 microlensing planets with a planet–host-star mass ratio of q < 1 × 10{sup -4}. We provide an additional mass–distance constraint on the lens host using near-infrared adaptive optics photometry from Keck/NIRC2. We are able to determine a flux excess of K {sub L} = 16.96 ± 0.11, which most likely comes entirely from the lens star. Combining this with constraints from the large Einstein ring radius, θ {sub E} = 1.40 ± 0.09 mas, and OGLE parallax we confirm this event as a super-Earth with a mass of m {sub p} = 4.43 ± 0.25M {sub ⊕}. This system lies at a distance of D {sub L} = 0.86 ± 0.05 kpc from Earth and the lens star has a mass of M {sub L} = 0.234 ± 0.012M {sub ⊙}. We confirm that with a star–planet mass ratio of q = 0.57 × 10{sup -4}, OGLE-2017-BLG-1434 lies near the inflexion point of the planet–host mass-ratio power law.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Restoring Redundancy to the MAP Propulsion System

The Microwave Anisotropy Probe (MAP) is a follow-on to the Differential Microwave Radiometer (DMR) instrument on the Cosmic Background Explorer (COBE). Due to the MAP project's limited mass, power, and financial resources, a traditional reliability concept including fully redundant components was not feasible. The MAP design employs selective hardware redundancy, along with backup software modes and algorithms, to improve the odds of mission success. In particular, MAP's propulsion system, which is used for orbit maneuvers and momentum management, uses eight thrusters positioned and oriented in such a way that its thruster-based attitude control modes can maintain three-axis attitude control in the event of the failure of any one thruster.

O'Donnell, James R., Jr.↗

High Current ESD Test of Advanced Triple Junction Solar Array Coupon

Testing was conducted on an Advanced Triple Junction (ATJ) coupon that was part of a risk reduction effort in the development of a high-powered solar array design by Space Systems Loral, LLC (SSL). The ATJ coupon was a small, 4-cell, two-string configuration of flight-type design that has served as the basic test coupon design used in previous SSL environmental aging campaigns. The objective of the present test was to evaluate the performance of the coupon after being subjected to induced electrostatic discharge (ESD) testing at two string voltages (100 V, 150 V) and four string currents (1.65 A, 2.0 A, 2.475 A, and 3.3 A). An ESD test circuit, unique to SSL solar array design, was built that simulates the effect of missing cells and strings in a full solar panel with special primary arc flashover circuitry. A total of 73 primary arcs were obtained that included 7 temporary sustained arcs (TSA) events. The durations of the TSAs ranged from 50 micro-seconds to 2.75 milli-seconds. All TSAs occurred at a string voltage of 150 V. Post-ESD functional testing showed that no degradation occurred due to the TSA events. These test results point to a robust design for application to a high-current, high-power mission.

Wright, Kenneth H., Jr.↗