Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical alignment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

GaAs circuits for monolithic optical controller

GaAs circuits for use in a fully monolithic 1 Gb/s optical controller have been developed and tested. The circuits include photodetectors, transimpedance amplifiers and 1:16 demultiplexers that can directly control the phase of MMIC phase shifters. The entire chip contains approximately 300 self-aligned gate E/D-mode MESFETs. The MESFETs have one micron-wide gate and the E-mode FETs typically have transconductance of 200 ms/mm. Results of simulations and tests are reported. Also, the design and layout of the fully monolithic chip is discussed.

Gustafson, G.↗

The influence of grain growth in circumstellar dust envelopes on observed colors and polarization of some eruptive stars

R CrB stars are classical examples of stars where dust envelope formation takes place. Dust envelope formation was detected around the Kuwano-Honda object (PU Vul) in 1980 to 1981 when the star's brightness fell to 8(sup m). Such envelopes are also formed at nova outbursts. The process of dust envelope formation leads to appreciable variations in optical characteristics, which are seen in specific color and polarization variations in the course of light fading and the appearance of IR radiation. It is shown that the model of a circumstellar dust envelope with aligned particles of changing size can be successfully applied to explain most phenomena observed at the time of light minima for a number of eruptive stars. The polarization may arise in a nonspherical dust envelope or be produced by alignment of nonspherical particles.

Efimov, Yu. S.↗

Quasars, blazars, and gamma rays

The paper discusses the extragalactic sources that have been discovered with the Energetic Gamma Ray Experiment Telescope. All of the sources demonstrate evidence of blazar properties at other wavelengths, including high optical polarization, extreme optical variability, flat-spectrum radio emission associated with a compact core, and apparent superluminal motion. These properties are believed to be produced by those few rare extragalactic quasars and radio galaxies that are favorably aligned to make it possible to observe almost directly down a relativistically outflowing jet of matter expelled from a supermassive black hole.

Dermer, Charles D.↗

SXI prototype mirror mount

The purpose of this contract was to provide optomechanical engineering and fabrication support to the Solar X-ray Imager (SXI) program in the areas of mirror, optical bench and camera assemblies of the telescope. The Center for Applied Optics (CAO) worked closely with the Optics and S&E technical staff of MSFC to develop and investigate the most viable and economical options for the design and fabrication of a number of parts for the various telescope assemblies. All the tasks under this delivery order have been successfully completed within budget and schedule. A number of development hardware parts have been designed and fabricated jointly by MSFC and UAH for the engineering model of SXI. The major parts include a nickel electroformed mirror and a mirror mount, plating and coating of the ceramic spacers, and gold plating of the contact rings and fingers for the camera assembly. An aluminum model of the high accuracy sun sensor (HASS) was also designed and fabricated. A number of fiber optic tapers for the camera assembly were also coated with indium tin oxide and phosphor for testing and evaluation by MSFC. A large number of the SXI optical bench parts were also redesigned and simplified for a prototype telescope. These parts include the forward and rear support flanges, front aperture plate, the graphite epoxy optical bench and a test fixture for the prototype telescope. More than fifty (50) drawings were generated for various components of the prototype telescope. Some of these parts were subsequently fabricated at UAH machine shop or at MSFC or by the outside contractors. UAH also provide technical support to MSFC staff for a number of preliminary and critical design reviews. These design reviews included PDR and CDR for the mirror assembly by United Technologies Optical Systems (UTOS), and the program quarterly reviews, and SXI PDR and CDR. UAH staff also regularly attended the monthly status reviews, and made a significant number of suggestions to improve the design, assembly and alignment of the telescope. Finally, a high level assembly and alignment plan for the entire telescope was prepared by UAH. This plan addresses the sequence of assembly, the required assembly and alignment tolerances, and the methods to verify the alignment at each step during the assembly process. This assembly and alignment plan will be used to assemble and integrate the engineering model (EM) of the telescope. Later on, based on this plan more detailed assembly and alignment procedures will be developed for the lower-level assemblies of SXI.

Source record↗

Planar Doppler Velocimetry for Large-Scale Wind Tunnel Testing

Recently, Planar Doppler Velocimetry (PDV) has been shown by several laboratories to offer an attractive means for measuring three-dimensional velocity vectors everywhere in a light sheet placed in a flow. Unlike other optical means of measuring flow velocities, PDV is particularly attractive for use in large wind tunnels where distances to the sample region may be several meters, because it does not require the spatial resolution and tracking of individual scattering particles or the alignment of crossed beams at large distances. To date, demonstrations of PDV have been made either in low speed flows without quantitative comparison to other measurements, or in supersonic flows where the Doppler shift is large and its measurement is relatively insensitive to instrumental errors. Moreover, most reported applications have relied on the use of continuous-wave lasers, which limit the measurement to time-averaged velocity fields. This work summarizes the results of two previous studies of PDV in which the use of pulsed lasers to obtain instantaneous velocity vector fields is evaluated. The objective has been to quantitatively define and demonstrate PDV capabilities for applications in large-scale wind tunnels that are intended primarily for the production testing of subsonic aircraft. For such applications, the adequate resolution of low-speed flow fields requires accurate measurements of small Doppler shifts that are obtained at distances of several meters from the sample region. The use of pulsed lasers provides the unique capability to obtain not only time-averaged fields, but also their statistical fluctuation amplitudes and the spatial excursions of unsteady flow regions such as wakes and separations. To accomplish the objectives indicated, the PDV measurement process is first modeled and its performance evaluated computationally. The noise sources considered include those related to the optical and electronic properties of Charge-Coupled Device (CCD) arrays and to speckle effects associated with coherent illumination from pulsed lasers. The signal noise estimates are incorporated into the PDV signal analysis process and combined with computed scattering signals using a Mie scattering theory for polydisperse smoke particles. The relevant parameters incorporate a range of practical aerodynamic test conditions and facility sizes. The results define the optimum instrument configurations, show that the expected signal levels from a practical PDV system are sufficiently large to allow its useful application in large facilities, and show that the expected velocity measurement uncertainties are small compared to the mean velocities of interest for most subsonic, large-scale wind tunnel testing. Experimental studies using several experimental bench-top setups are then described that validate the physics of the PDV model and to calibrate its computed results. The validated model allows estimates of the uncertainties of PDV measurements and a complete definition of the PDV capabilities to be made with sufficient confidence to decide the viability of PDV for large-scale wind tunnel applications.

McKenzie, Robert L.↗

Interfacial Charge Transfer in Lead Sulfide/Cadmium Sulfide Quantum Dot–Monolayer Molybdenum Disulfide Heterostructures

We investigate the ultrafast interfacial charge transfer dynamics in mixed-dimensional PbS/CdS quantum dot (QD)–monolayer MoS 2 heterostructures exhibiting a type-II band alignment. These 0D–2D heterostructures were assembled using oleic acid-capped PbS/CdS QDs with systematically varied core sizes deposited onto molecular beam epitaxy-grown monolayer MoS 2 . Steady-state and time-resolved optical spectroscopies revealed pronounced bidirectional charge transfer between the 0D and 2D components, involving both electron and hole exchange across the interface. The quenching of the monolayer MoS 2 A-exciton bleach and the modifications of its decay dynamics provide direct evidence for efficient hole transfer from photoexcited MoS 2 into the PbS QD core. Concurrently, attenuation of the QD ground-state bleach and the emergence of ultrafast decay components confirmed electron transfer from photoexcited QDs to monolayer MoS 2 . Both hole and electron transfer processes are dependent on the QD core size, with smaller cores enabling faster transfer rates and higher efficiencies due to enhanced band offsets and interfacial coupling. The complementary insights gained from transient absorption and time-resolved photoluminescence measurements clarify the mechanisms governing interfacial carrier exchange and highlight the importance of both hole and electron transfer as key components in the functioning of such 0D–2D heterostructures. This study underscores the potential of 0D–2D semiconductor heterostructures for advanced optoelectronic and light-energy conversion applications.

36 MATERIALS SCIENCE↗

Using Fourier-Plane Imaging Microscopy for Determining Transition-Dipole-Moment Orientations in Organic Light-Emitting Devices

Here, we use Fourier-plane imaging microscopy (FIM) to determine the transition-dipole-moment orientation in doped organic emissive thin films. The use of FIM enables precise, sensitive, and rapid measurement of dipole orientation in the emission layer of an organic light-emitting device (OLED). An optical model of a stratified birefringent multilayer is introduced for interpreting results obtained by FIM. Using the model, we determine the average orientation of transition-dipole-moment vectors of three phosphorescent dopant emitters. The dipole alignment measured by FIM quantitatively explains the difference in OLED efficiencies using these archetype dopant molecules. FIM provides a nondestructive tool to measure and ultimately improve the outcoupling efficiency of OLEDs and other light-emitting devices.

74 ATOMIC AND MOLECULAR PHYSICS↗

AutoFocus: AI-driven alignment of nanofocusing X-ray mirror systems

We describe the application of an AI-driven system to autonomously align complex x-ray-focusing mirror systems, including mirrors systems with variable focus spot sizes. The system has been developed and studied on a digital twin of nanofocusing X-ray beamlines, built using advanced optical simulation tools calibrated with wavefront sensing data collected at the beamline. We experimentally demonstrated that the system is reliably capable of positioning a focused beam on the sample, both by simulating the variation of a beamline with random perturbations due to typical changes in the light source and optical elements over time, and by conducting similar tests on an actual focusing mirror system.

47 OTHER INSTRUMENTATION↗

Distributions and characteristics of high-latitude field aligned electron precipitation

Satellite measurements of field-aligned auroral electron precipitation were analyzed using 16 months of data from the OGO-4 auroral particles experiment. It was observed that the anisotropies are of short time duration and are most likely to occur when particle fluxes are high. Field-aligned 2.3 keV electron precipitation is found in an oval shaped region primarily in the nighttime hours, with a maximum probability at approximately 70 deg invariant latitude near midnight, congruent to and poleward of the auroral optical emissions in these hours. This precipitation was found to be associated with the high latitude boundary of auroral electron precipitation during substorm expansion and is characterized by a harder and more intense energy spectrum than typical isotropic precipitation.

Berko, F. W.↗

Distributions and characteristics of high-latitude field-aligned electron precipitation.

Satellite measurements of field-aligned auroral electron precipitation have been analyzed using 16 months of data from the OGO 4 auroral particles experiment. As can be seen from the moving satellite, the anisotropies are of short duration and are most likely to occur when particle fluxes are high. Field-aligned 2.3-keV electron precipitation is found in an oval-shaped region primarily in the nighttime hours; maximum probability is at about 70 deg invariant latitude near midnight, congruent to and poleward of the auroral optical emissions in these hours. This precipitation is found to be associated with the high-latitude boundary of auroral electron precipitation during substorm expansion and is characterized by a slightly harder and considerably more intense energy spectrum than typical isotropic precipitation.-

Berko, F. W.↗

An experimental evaluation of the Hamrock and Dowson minimum film thickness equation for fully flooded EHD point contacts

Fifty-seven measurements of the minimum lubricant film separating the elastohydrodynamically lubricated point contact of a steel crowned roller and a flat sapphire disk were made by an optical interferometry technique. The data collected were used to evaluate the Hamrock and Dowson minimum EHD film thickness model over a practical range of contact ellipticity ratio where the major axis of the contact ellipse is aligned both parallel and perpendicular to the direction of motion. A statistical analysis of the measured film thickness data showed that on the average the experimental data averaged 30 percent greater film thickness than the Hamrock and Dowson model predicts.

Koye, K. A.↗

High altitude AM0 testing of PV concentrator lens elements

Recently, the NASA Lewis Research Center modified its Lear High Altitude Test Facility to fly two prototype ENTECH minidome Fresnel lens photovoltaic concentrator elements. The tests were highly successful, and the results verified the ability of the Lear High Altitude Facility to measure the optical performance of individual concentrator lens elements and concentrator/cell combinations at near AM0 insolation conditions. The two concentrator lenses flown achieved optical efficiencies, based on a gallium arsenide concentrator cell response, of 89.8 percent and 90.0 percent. The flights demonstrated the ability of the aircraft to maintain the pointing accuracy required to obtain useful data. With proper alignment of the collimating tube and the pilot's sunsight, this facility could easily maintain a pointing accuracy of + or - 0.5 deg for a sufficiently long time to obtain accurate, reproducible results.

Piszczor, M. F.↗

STIS Coronagraphic Imaging of Fomalhaut: Main Belt Structure and the Orbit of Fomalhaut b

We present new optical coronagraphic data of Fomalhaut obtained with HST/STIS in 2010 and 2012. Fomalhaut b is recovered at both epochs to high significance. The observations include the discoveries of tenuous nebulosity beyond the main dust belt detected to at least 209AU projected radius, and a approx. 50AU wide azimuthal gap in the belt northward of Fomalhaut b. The two epochs of Space Telescope Imaging Spectrograph (STIS) photometry exclude optical variability greater than 35%. A Markov chain Monte Carlo analysis demonstrates that the orbit of Fomalhaut b is highly eccentric, with e = 0.8 +/- 0.1, a = 177 +/- 68AU, and q = 32 +/- 24AU. Fomalhaut b is apsidally aligned with the belt and 90% of allowed orbits have mutual inclination <=36 deg. Fomalhaut b's orbit is belt crossing in the sky plane projection, but only 12% of possible orbits have ascending or descending nodes within a 25AU wide belt annulus. The high eccentricity invokes a dynamical history where Fomalhaut b may have experienced a significant dynamical interaction with a hypothetical planet Fomalhaut c, and the current orbital configuration may be relatively short-lived. The Tisserand parameter with respect to a hypothetical Fomalhaut planet at 30AU or 120AU lies in the range 2-3, similar to highly eccentric dwarf planets in our solar system. We argue that Fomalhaut b's minimum mass is that of a dwarf planet in order for a circumplanetary satellite system to remain bound to a sufficient radius from the planet to be consistent with the dust scattered light hypothesis. In the coplanar case, Fomalhaut b will collide with the main belt around 2032, and the subsequent emergent phenomena may help determine its physical nature.

Tisserand parameter↗

Efficient and tunable blue light generation using lithium niobate nonlinear photonics

Thin-film lithium niobate (LN) has recently emerged as a playground for chip-scale nonlinear optics and leads to efficient frequency conversions from near-infrared to near-visible bands. For many nonlinear and quantum photonics applications, it is desirable to operate deep into the visible band within LN's transparency window. However, the strong material dispersion at short wavelengths makes phase-matching difficult, necessitating sub-micrometer scale control of domain structures for efficient phase-matching. Here, we report the operation of thin film LN in the blue wavelength and high fidelity poling of the thin-film LN waveguide to this regime. As a result, quasi-phase matching is realized between IR (871 nm) and blue (435.5 nm) wavelengths in a straight waveguide and prompts strong blue light generation with a conversion efficiency (1040% ± 140%/W). This blue second harmonic generator exhibits stable temperature tunability, which is important for applications that require precise frequency alignment, such as atomic clocks.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement Capabilities of Planar Doppler Velocimetry in Large-Scale Wind Tunnels

Over the past few years, Planar Doppler Velocimetry (PDT) has been shown by several laboratories to offer an attractive means for measuring three-dimensional velocity vectors everywhere in a light sheet placed in a flow. Unlike some other optical means of measuring flow velocities, PDT is particularly attractive for use in large wind tunnels where distances to the sample region may be several meters, because it does not require the spatial resolution and tracking of individual scattering particles or the alignment of crossed beams at large distances. To date, demonstrations of PDT (also called Doppler Global Velocimetry by some authors) have been made either in low speed flows without quantitative comparison to other measurements, or in supersonic flows where the Doppler shift is large and its measurement is relatively insensitive to instrumental errors. Moreover, most reported applications have relied on the use of continuous-wave lasers, which limit the measurement to time-averaged velocity fields. This work summarizes the results of two previous studies of PDT in which the use of pulsed lasers to obtain instantaneous velocity vector fields is evaluated. The objective has been to quantitatively define and demonstrate PDT capabilities for applications in large-scale wind tunnels that are intended primarily for the testing of rotorcraft and subsonic aircraft at speeds typically less than 100 m/s. For such applications, the adequate resolution of low-speed flow fields requires accurate measurements of small Doppler shifts that are obtained at distances of several meters from the sample region and with a field of view that is sufficient to encompass the entire region of interest. The use of pulsed lasers provides the unique capability to obtain not only time-averaged fields, but also their statistical fluctuation amplitudes and the spatial excursions of unsteady flow regions such as wakes, separations, and rotor-tip vortices. To accomplish the objectives of these studies, the PDT measurement process was first modeled and its performance evaluated computationally. The noise sources considered included those related to the optical and electronic properties of Charge-Coupled Device (CCD) arrays and to speckle effects associated with the coherent illumination of aerosols from pulsed lasers. The signal noise estimates were incorporated into the PDT signal analysis process and combined with computed scattering signals using a Mae scattering theory for a distributed range of aerosol particle sizes. The results are used to define the necessary instrument configuration, to show that the expected signal levels from a practical PDT system are sufficiently large to allow its useful application in large facilities, and to show that the expected velocity measurement uncertainties are small compared to the mean velocities of interest for most subsonic, large-scale wind tunnel testing, Experimental studies using several bench-top setups are then described that validate the physics of the PDT model and demonstrate the ability to obtain accurate PDT measurements using procedures that are compatible with large-scale wind tunnel operations. The PDT measurement capabilities found in this study lead to the conclusion that PDT offers significant advantages compared to other means of measuring velocity fields in large-scale wind tunnels, including those operating at low speeds.

McKenzie, Robert L.↗

Spontaneous Valley Polarization of Interacting Carriers in a Monolayer Semiconductor

Here, we report magnetoabsorption spectroscopy of gated WSe 2 monolayers in high magnetic fields up to 60 T. When doped with a 2D Fermi sea of mobile holes, well-resolved sequences of optical transitions are observed in both σ ± circular polarizations, which unambiguously and separately indicate the number of filled Landau levels (LLs) in both K and K ' valleys. This reveals the interaction-enhanced valley Zeeman energy, which is found to be highly tunable with hole density p . We exploit this tunability to align the LLs in K and K ' , and find that the 2D hole gas becomes unstable against small changes in LL filling and can spontaneously valley polarize. These results cannot be understood within a single-particle picture, highlighting the importance of exchange interactions in determining the ground state of 2D carriers in monolayer semiconductors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of Advanced, Radiation Resistant, Optical-based Detector Technology for Future Experiments.

The primary objective of this project has been to advance the design of high-performance electromagnetic (EM) calorimeters for future particle physics experiments, to identify and measure the timing, position and energy of electrons, positrons and gamma rays, particularly in high-luminosity environments with intense radiation and pileup conditions. To meet such challenges, the proposed research has focused on the development of ultra-compact, radiation-hard calorimeter modules, to provide excellent timing, spatial, and energy resolution. The work aligns with the DOE’s Basic Research Needs (BRN) for High Energy Physics (HEP) Instrumentation and the research team contributes actively to the Coordinating Panel on Advanced Detectors (CPAD) RDC9 calorimetry collaboration in the USA and the European Committee on Future Accelerators (ECFA) DRD-CALO calorimetry collaboration at CERN, the European Laboratory for Particle Physics located in Geneva, Switzerland. The research builds on the RADiCAL (radiation-hard, ultra-compact) modular sampling calorimeter approach, developed by the research team, which employs dense and very bright optical materials such as LYSO:Ce scintillator plates that are interleaved with very dense tungsten plates to minimize detector size while optimizing performance. The modules are comparable in size to a human index finger, dimensionally 14 mm x 14 mm in cross section and 135 mm in length. And despite the small size, the structure is capable of providing excellent timing and energy resolution. This is facilitated through the use of specialized quartz capillaries filled with wavelength-shifting filaments, positioned at various depths along the length of a module, to collect and guide light signals to silicon photomultipliers (SiPMs) which detect and convert the optical signals to electronic signals for analysis. The primary goals of this project have been: (1) Achieve a timing resolution to σ t ≤ 30 ps for high-energy electrons and photons, important for their association with specific events produced in colliding-beam experiments and for the detection of decays-in-flight of long-lived particles. The project has achieved this goal in beam tests of a single RADiCAL module at CERN, during which a timing resolution of σ t = 27 ps was measured for electrons of energy E = 150 GeV. Based upon a mathematical fit to the data measured over a broad energy range from low energy to high energy, a resolution of σ t ≤ 18 ps has been estimated for electrons of very high (TeV) energy. From these measurements and with further expected technical improvements, the timing resolution should reach σ t ≤ 10 ps, important for searches for discovery physics in upcoming and future experiments. (2) Achieve an energy resolution of σ E / E ≤ 10% / $\sqrt{E}$. The project has yet to achieve this goal, but is close to it, having measured a value of σ E / E ≤ 15.9% / $\sqrt{E}$ using a modular array. Ultimately, the resolution goal is expected to be reached by adjustments to material thicknesses within the modules, which will improve the sampling fraction to measure more precisely the shower energy for lower energy particles. The versatility of the modular RADiCAL approach enables the testing of advanced materials, photosensors and electronics, developed in collaboration with CPAD RDC and ECFA DRD-CALO groups. The structure can distinguish electrons, positrons and gamma rays from hadrons and muons and beam-induced backgrounds, making it a valuable tool in a variety of detector environments, including future circular colliders (FCC-ee, FCC-hh) proposed for the European Laboratory for Particle Physics (CERN), the muon-collider proposed for Fermi National Accelerator Laboratory (Fermilab), and searches for new physics in beam-dump, fixed target and forward-physics experiments. And, while designed with particle physics applications in mind, the technologies developed in this project have the potential for application more broadly in particle and nuclear physics, materials science, and medical physics, underscoring the far-reaching potential of this line of instrumentation research and development.

47 OTHER INSTRUMENTATION↗