Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “normalization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Design of Nuclear Criticality Safety Framework for Hands-on Construction of Fast Systems Over Ranges of Multiplication

Since 1945, Los Alamos National Laboratory (LANL) has performed critical experiments, primarily at the Los Alamos Critical Experiments Facility (LACEF) at Technical Area 18 (TA-18). Since 2011, these experiments have been conducted by the National Criticality Experiments Research Center (NCERC), operated by LANL, at the Device Assembly Facility (DAF) in the Nevada National Security Site (NNSS). These experiments utilize various types of Special Nuclear Material (SNM). Some of these experiments utilize what is referred to as the Rocky Flat Shells, which are called such as they came from the Rocky Flats Plant. These concentric hemi-shells are made of Highly Enriched Uranium (HEU), which is 93 w/o 235U. Fig. 1. Subset of the Rocky Flat Shells LANL is designing a new subcritical hands-on experiment with the goal of achieving a neutron multiplication in the range of 50 to 200, which correlates to Keff values of 0.98 to 0.995. ANSI/ANS-1 is the standard for Conduct of Critical Experiments which governs critical operations at NCERC. Section 3.9 of ANSI/ANS-1 states that when manipulating a critical assembly by hand, the predicted k eff of a known configuration should not exceed 0.95 (a neutron multiplication of 20). This presents a challenge, as this system would have a higher multiplication than 20 and the assembly would have to remain subcritical in normal and credible accident scenarios. To ensure the safety of such an assembly, the different normal and abnormal conditions that could alter the criticality 1 MCNP® and Monte Carlo N-Particle® are registered trademarks owned by Triad National Security, LLC, manager and operator of Los Alamos National Laboratory. Any third party use of such registered marks should be properly of the system must be considered and analyzed. If such a condition is deemed to be credible, it will be further investigated using the Monte Carlo N-Particle (MCNP) transport code. If the results of these simulations show that a k eff larger than one could be possible, modifications to the assembly will be made until such an event is deemed no longer possible.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

01-07 Reactor Supplemental Shielding For the NRIC DOME Test Bed 01-07 Reactor Supplemental Shielding For the NRIC DOME Test Bed 2

A radiation shielding system is needed to protect personnel and equipment from harsh neutron and photon fluxes during: Reactor operations Post shut down operations Disassembly Decommissioning Examples of RSS driving requirements Radiological Controls Operating dose rate: the dose rate during normal reactor operations shall be <0.5 mrem/hr at the exterior wall of DOME containment Outdoor radiation limit: shielding shall provide the dose to a facility worker outside of DOME to <0.05 mrem/hr at 50 ft from the exterior wall of the DOME Temperature Reactors may have operating temperatures up to 800C The RSS shall be capable of removing up to 100 KW of heat during normal operating conditions the concrete structure has an upper temperature limit of 100°C

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Novel Technique for Distributed Measuring of Strain in the Vadose Zone

Characterizing water content and pressure changes in the vadose zone is important to understanding a variety of geologic processes, ranging from permeability, to evapotranspiration, and aquifer recharge. Changes in water content, or pressure, cause strain in the solid porous medium of the vadose zone, and it is possible that measuring those strains could be used a characterization tool. The Coherence-length-gated Microwave Photonics Interferometry (CMPI) technique measures strain at high resolution along many intervals defined by pairs of reflectors distributed along an optical fiber. This technique has recently been developed at Clemson University, and it has the spatial, and temporal resolution to characterize the strains that are expected to occur with hydrologic changes in the vadose zone. However, the technique has never been used to measure strain in porous media, so its capabilities remain uncertain. The objective of this thesis is to evaluate the ability of using CMPI to measure strain changes in the vadose zone. The research approach consists of conducting laboratory tests using a column filled with sand that was subjected to changes in water content and pressure. An optical fiber with CMPI reflectors was deployed in a high surface area ribbon and used to measure strain along the axis of the column. The column was made from 8-inch, Schedule 40 PVC pipe (75 cm tall, 20 cm inner diameter) and filled with medium-grained sand (K = 2.5x10-6 m/s, porosity = 0.28, Coefficient of Uniformity = 2, van Genuchten (n = 4.34 and  = 0.00039 m-1), Young’s Modulus = 18 – 47 MPa). Five pressure and four temperature sensors attached to probes inserted into the wall. The optical fiber includes five reflectors spaced 10 cm apart on the inside and outside of the column along the vertical axis. Strain measurements are made between pairs of reflectors. The reflectors are created in 250-micron-diameter acrylate-coated single mode Corning SMF28e+ optical fiber using a femtosecond laser. The optical fiber was laminated between two pieces of polyester film creating a large surface area to transfer strain from the porous media to the optical fiber. The experiments were conducted by filling the column from the bottom or infiltrating water from the top. The water was allowed to equilibrate to room temperature prior to each test in order to limit thermoelastic strain. Five injection tests with a rate of 250 ml/min and three infiltration tests at varying rates were conducted, and the results show patterns of strain and pressure are generally similar. Hydrologic conditions define three zones based on the pressure magnitude and distribution. 1.) Ambient Zone where the pressure heads are quasi-static and the pressure gradient is roughly unity (head gradient of zero). This is the uppermost zone and is characterized by negative pressures. 2.) Transition Zone where the pressures increase from ambient to zero, are changing relatively rapidly and the pressure gradient is relatively steep (pressure head gradients of 2). The Transition zone is 10 to 15 cm thick. 3.) Positive Pressure Zone where the pressure is positive, the rate of change is slower than in the transition zone and the gradient is flatter (pressure head gradient 1.1 to 1.2). This is the lowest zone in the column. Injection of water causes the pressure to increase and the three zones to move upward. The Transition zone moves at a rate of approximately 0.0002 m/s +/- .00005, according to analyses of pressure profiles. This is the same as the average velocity of the water calculated as volumetric flux/effective porosity =5.4x10-5 m/s/0.28. Strain signals in the range of 10s  were observed with a noise level of generally less than 0.1  (signal to noise ratio of greater than 100) during injection and drainage. The spatial and temporal distributions of strain caused by injection depend on the location of the moving pressure zones. The locations of the different pressure zones were determined from pressure profiles at different times and these data were transferred to strain time series. This showed that strain in the Ambient pressure zone is either unchanged or slightly compressive, whereas strain in Transition zone is tensile and roughly proportional to the pressure change, and strain ranges from tensile to compressive in the Positive Pressure zone. In general, the strain is variable at the top of the Positive Pressure zone, but it appears to be consistently tensile lower in the zone. The spatial distribution of strain causes three distinct stages in the strain times series measured between pairs of CMPI reflectors. The strain is unchanged or slightly compressive during Stage 1, it increases (positive strain is tensile) approximately linearly at a rate of 0.02 to 0.03 μ/s during the Stage 2, and then flattens out in Stage 3. The strain increases again during Stage 4 of the time series. The pressure also changes in stages. It is unchanged during Stage 1 and then increases relatively rapidly at a rate of between 4 and 10 Pa/s during Stage 2 and continues to increase during Stages 3 and 4, but at a rate slightly slower than during Stage 2 (from 2.5 to 3.5 Pa/s). The rates of pressure and strain change are consistent with basic analyses. The rate of pressurization is similar to the calculated velocity of flow in the saturated zone, and this is similar to the measured velocity of the strain increase. The ratio of the pressurization rate and strain rate during Stage 2 (2.5 (Pa/s) /0.03 (μ/s)) is 80 MPa, which is approximately equal to the upper range expected considering the uniaxial compression and the Young’s Modulus of the sand. An interesting effect occurs when the upper surface of the sand becomes saturated. Significant compression (several 10s of ) occurs as the pressure and saturation increase at the upper surface. Compression occurs throughout the column, but the effect is greatest at the top of the column. The rate of compression is fastest slightly before ponding occurs, but it slows markedly and nearly stops when water starts to accumulate at the surface (ponding). This effect reverses when the surface of the sand is drained, resulting in tension throughout the column. The compression caused by this effect can be as large or larger than the tensile strain that accumulated during filling. This effect was unexpected because increasing pressure is normally associated with tensile strain. Nevertheless, this effect was observed consistently in all tests where the pressure changes at the upper surface, including tests where water was injected from below or infiltrated from above. This effect behaves as if the pore pressure at the upper surface of the sand exerts a normal force on the boundary (increasing pore pressure exerts a downward compression on the boundary). The results of these laboratory experiments indicate that CMPI can measure strain caused by fluid pressure changes in the vadose zone with a signal to noise ratio of 100 or more. Injection and drainage cause a strain signal that is complex, but repeatable. The magnitudes of the strain signal are consistent with magnitudes that are expected based on poroelastic calculations using independently measured properties of the sand. These results indicate that the CMPI technique with an optical fiber laminated in a polyester ribbon generates data that represent the strain distribution during hydrologic processes of imbibition and drainage in variably saturated sand. This suggests that distributed strain measurements using CMPI could be a viable approach for evaluating processes in the vadose zone, laying the groundwork for future field implementation.

47 OTHER INSTRUMENTATION↗

Beam Dynamics simulations for ERDC project -- SRF linac for industrial use

Compact conductively cooled SRF industrial linacs can provide unique parameters of the electron beam for industrial applications. (up to 10MeV, 1MW). For ERDC project we designed normal conducting RF injector with thermal RF gridded gun integrated in first cell of multi-cell cavities. For design of the RF gun we used MICHELLE software to simulate and optimize parameters of the beam. Output file was converted to ASTRA format and most beam dynamic simulations in multi-cell normal conducting cavity and cryomodule were performed by using ASTRA software. For cross-checking we compare results of MICHELLE and AS-TRA in first few cells. At the end of injector beam reach ~250keV energy which allow to trap bunch in acceleration regime without losses in TESLA like 1.3 GHz cavity. Short solenoid at the end of injector allow to regulate transverse beam size in cryomodule to match beam to extraction system and also reduce charge losses in accelerator.

43 PARTICLE ACCELERATORS↗

"Source Term Modeling for Advanced Gas Micro-Reactors"

Maintaining the safety of the public, environment, and operating personnel is the most important factor in designing, operating, maintaining, and decommissioning nuclear reactors. In recent years, there has been a growing interest in the development of micro-reactors employing TRi-structural ISOtropic (TRISO)-coated particle fuel. In gas reactors, TRISO fuel plays an important role in the safety case for high temperature reactors because of the fission product retention properties of the fuel. This ability enables the use of a functional containment strategy for the reactor where multiple barriers are used to prevent fission product release to the environment. Part of the safety analysis of these advanced reactors is the assessment of radionuclide releases under normal and accident conditions through the multiple credited safety barriers. Using conservative assumptions, a mechanistic analysis can be performed to quantify these releases that combines the probabilistic assessment of failure with analytic solutions to radionuclide transport equations. Source term modeling for TRISO fuel has been performed for previous reactor designs; however, these models are outdated, in many cases proprietary, and need updates to be applied to the current state of TRISO fuel technology and alternative gas reactor core configurations [1]. Currently, the only publicly available source term assessment for gas reactors is an expert-based Monte Carlo simulation based on the effectiveness of the fuel kernel, coating layers, and graphite block in a modular high temperature gas reactor [2]. Thus, there is a need to develop a simple, versatile, and mechanistic model of fission product release and transport in gas reactor cores that could be applied to a variety of reactors through user inputs and reactor-specific radionuclide inventories. The release is calculated by the diffusion of the key safety important fission products through the kernel, silicon carbide (SiC), graphite for both intact and defective TRISO particles based on fuel and graphite temperatures in the reactor under normal operation. These releases from the fuel enter the coolant where they can plate-out on cooler surfaces. A clean-up model is included for designs with a coolant purification system to remove fission gases. This initial distribution of fission products in the reactor serves as an initial condition for potential releases under postulated accident conditions. The model then can calculate the fission product release for any transient temperature profile and fission product releases can then be used to assess radiological dose to the workers and the public using conventional dose tools. Data on the diffusion of fission products is based on historic German TRISO experiments and the more current Department of Energy (DOE) Advanced Gas Reactor (AGR) TRISO fuel development program. The model is coded in python with inputs and outputs in excel spreadsheets, as well as python plotting utilities to aid in the interpretation of the results. References: [1] INL, NGNP Mechanistic Source Term White Paper, INL-10-17997, July 2010. [2] David A. Petti, Richard R. Hobbins, Peter Lowry, Hans Gougar, “Representative Source Terms and The Influence of Reactor Attributes on Functional Containment in Modular High Temperature Gas-cooled Reactors,” Nuclear Technology, Vol. 184, p. 181-197, Nov. 2013.

07 ISOTOPE AND RADIATION SOURCES↗

Fuel Performance Evaluation of THOR-C Experiments

The Temperature Heatsink Overpower Response Commissioning (THOR-C) and THOR-Metal (THOR-M) experiments will be performed as part of an ongoing project for testing sodium fast reactor fuels with the Japan Atomic Energy Agency (JAEA). The THOR-C experiments consist of fresh metallic fuel pins and have been analyzed using the ABAQUS, Ansys codes and the BISON fuel performance code. THOR-M-Loss of Flow-1 (THOR-M-LOF-1) is designed to test an EBR-II irradiated fuel pin under LOF conditions. Simulation of the THOR-MLOF-1 experiment required first simulating the base irradiation of the fuel pin in EBR-II. MFUEL module of SAS4A/SASSYS-1 [1] is a physics-based metallic fuel performance model applicable to the normal operation, transient scenarios and fuel failure modeling including scenarios with bulk fuel melting. The model has been validated using EBR-II normal operation, separate effect transient tests as well as TREAT M-Series transient tests [2]. In this study, MFUEL models has been utilized together with a new capsule heat transfer model developed in this project. The new heat transfer model was necessary due to (1) significant amount of heat losses that required 2D heat transfer, (2) the presence of a titanium heat sink, rejecting a significant amount of heat, and (3) stagnant coolant conditions, which are inconsistent with SAS4A/SASSYS-1 (SAS) heat transfer model. Updates to SAS4A/SASSYS-1 and MFUEL has been described below, followed by a preliminary validation effort using the results from THOR-C-2 fresh fuel capsule experiment. A previous study for THOR-C-2 analysis using BISON code is also utilized in this study to model this test [3]. [1] D. O’Grady, A. J. Brunett, L. Ibarra, A. Karahan, T. Kim, T. S. Sumner, R. Thomas, T. H. Fanning, “The SAS4A/SASSYS-2 Version 5.7 Safety Analysis Code System,” Argonne National Laboratory,ANL/NSE-SAS/5.7, (2023). [2] A. Karahan, T. Kim, T. Fanning, D. O’Grady, “Validation of MFUEL Metal Fuel Performance Models of SAS4A/SASSYS-1,” Argonne National Laboratory, ANL/NSE-23/11, (2023). [3] M. Mihelish, A. Zabriskie, K. Paaren, P. Medvedev, C. Jensen, “Fuel Performance Predictions for the TREAT THOR-C Experiments,” Idaho National Laboratory, INL/RPT-23-73397, Revision 0, (2023)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Light Detecting and Ranging (LIDAR) for in-situ heliostat optical error assessment

A system and method for optical assessment of a heliostat includes obtaining a point cloud data representing an image of the heliostat; isolating the data; filtering and fitting the filtered heliostat data to a bounding box; translating the heliostat data to a plane to aid in segmentation; segmenting a plurality of facets of the heliostat fitting each of the segmented facets to a respective plane; generating normal vectors characterizing each of the plurality of facets; and calculating a canting angle associated with each respective facet of the plurality of facets. A heliostat with mirrored facets and a scanner are provided. The scanner captures point cloud data representing the heliostat, which is segmented for each facet. Normal vectors characterize the facets and a canting angle is calculated for the respective facet.

Small, Daniel E.↗

Methods for making high-temperature thermocouples

Methods of manufacturing thermocouples having a first thermoelement wire comprises a molybdenum-lanthanum based material and a second thermoelement wire comprises a phosphorus-doped niobium, may involve exposing a first thermoelement wire and a second thermoelement wire to a temperature in a range extending from about 50° C. to about 60° C. above an intended operational temperature of the first and second thermoelement wires and until a rate of change of a normalized voltage output of the first thermoelement wire and the second thermoelement wire is about 0.001 normalized Volts per hour or less.

Skifton, Richard S.↗

DROP DURABILITY ASSESSMENT OF ELECTRONIC ASSEMBLIES UNDER OFF-AXIS LOADING WITH SKEWED FIXTURES

This thesis studies drop durability of electronic assemblies when the acceleration vector is oriented at 45° to the out-of-plane direction of the circuit card. The off-axis drop tests are accomplished with a skewed fixture and are conducted as a proxy for multiaxial drop testing. Advanced shock testing and vibration test methods have been developed over the last few decades to better represent real-world field environments during ground-based laboratory testing. However, many of these test methods require expensive and specialized equipment not available in most laboratories. An alternative approach for approximating simultaneous loading along multiple axes on conventional equipment utilizes skewed fixtures which have seen use in off-axis random vibration and drop impact testing. These methods generally rely on the conversion of a uniaxial input load from the test equipment (using a uniaxial drop tower or shaker) into a multiaxial load when resolved in the reference frame of the test article (mounted on a skewed fixture). Skewed fixture design is presented and recommendations for conducting skewed angle drop testing are introduced based on local measurements along the skewed face of the fixture to accurately monitor the impact event. Characterization tests were performed with a skewed fixture, at simultaneous acceleration loads from 500 to 3,000 g in two (in-plane and out-of-plane) directions, while meeting standard time domain tolerances. Upon experimental characterization, drop shock durability tests were conducted on a printed circuit assembly (PCA). Mean drops-to-failure were measured and quantified with Weibull statistics. Dominant solder joint failure modes were identified via failure analysis. Prior work on inclined angle impact testing is limited, and the majority of solder joint interconnect level fatigue studies are conducted considering perpendicular loading normal the circuit card. Low-cycle fatigue curves are generated based on plastic strain and plastic work density within the solder joint. A multiscale nonlinear finite element model is used to relate board-level flexure to solder joint interconnect level plastic strain. A high strain rate solder constitutive model allows for accurate modeling of solder plasticity resulting from high-impact drop shock. Fatigue parameters are computed from the Coffin-Manson relation and Palmgren-Miner damage accumulation. This work serves to apply established low-cycle fatigue methods for conventional drop shock loading (impact normal to circuit card) to non-perpendicular loading with a skewed fixture.

Hower, Jonathan [Kansas City National Security Cam↗

Interfacial Analysis of Blister Formation in U-10Mo Mini-Plates

A thorough investigation of potential failure mechanisms builds confidence in the performance of monolithic U-10wt%Mo (U-10Mo) fuel plates. The lowenriched uranium (LEU) fuel system is currently undergoing qualification as a high U-density fuel that can be used to convert United States high-performance research reactors from high-enriched uranium (HEU) operation. This will require establishing fuel operational limits such that fission products and a coolable geometry are retained, even during off-normal reactor operation conditions [1]. Such off-normal conditions can subject the fuel plates to temperatures where the internal pressure of precipitated fission gasses result in a permanent deformed, raised area of the cladding, referred to as a blister. These blisters can reduce the local coolability of a fuel plate and can even close coolant channels of a fuel assembly, so blistered plates are considered failed regardless of whether the fuel is truly breached. Historically, a marginto- failure is established through out-of-pile blister threshold testing of irradiated fuel plates. This is accomplished by incrementally heating irradiated fuel plates until blisters are observed. This reveals the temperature threshold that would have resulted in a blister if a plate experienced them at those irradiation conditions [2]. While the blister testing itself reveals the temperatures at which the cladding mechanical integrity was exceeded, a more thorough investigation of the interface evolution in proximity to formed blisters may reveal mechanisms as to the blister formation and retention of fission gases. Previous studies have explored potential underlying mechanisms in historical plates that may have been close to blistering [3]; however, this work is the first exploration of blister tested irradiated plates, fabricated by a commercial vendor—another requirement for qualification of the fuel system [1]. The Mini-plate 1 (MP-1) experiment was the first in a series of irradiation and post-irradiation examination (PIE) campaigns to qualify the U-10Mo monolithic fuel system. It consisted of commercially fabricated 25.4×101.5 mm Al-clad mini-plates with a monolithic U-10Mo foil coated in a Zr diffusion barrier. The primary MP-1 PIE campaign was previously completed. Among the suit of examinations was a blister testing campaign, where plates were incrementally annealed in 25°C increments until blisters were observed or a maximum temperature of 550°C was reached [4]. The previously blistered plates from this campaign were revisited in this work.

25228↗

MARVEL Reactor Fuel Performance Report

The Microreactor Applications Research Validation and EvaLuation (MARVEL) project is producing a high temperature liquid metal-cooled nuclear test bed at Idaho National Laboratory (INL) to ultimately improve the integration of microreactors to end-user applications. This ambitious effort seeks to design, authorize, construct, test, and operate the reactor within five years. In order to construct and operate the MARVEL reactor in a timely manner, the system will utilize materials and component designs which have already been used, qualified, or licensed from previous reactors. The MARVEL reactor will be located at the INL Transient Reactor Test (TREAT) facility in the north high-bay equipment pit and will use the existing 304 stainless steel-clad U-ZrH1.6 pin-type fuel system developed by General Atomics and purchased from TRIGA International. This fuel has been previously qualified under the United States Department of Energy’s (US DOE) Reduced Enrichment for Research and Test Reactors (RERTR) Program. Even though the regulator of the MARVEL reactor is the US DOE, the standards and overall approach recommended by the Nuclear Regulatory Commission is well-defined and utilized here. Following NUREG-1537 regulatory guidance, this report documents the authorization case for the MARVEL fuel system’s application to MARVEL and establishes stable and predictable fuel performance during the most thermophysically unfavorable conditions achievable in the MARVEL reactor. To that end, this report provides a comprehensive survey of the known thermophysical properties, performance, and quantitative relationships associated with the MARVEL reactor fuel element and uses this information to determine its mechanical integrity and risk of reaching unacceptable conditions during the most extreme accident scenarios predicted for the reactor using the most conservative assumptions available. The information contained herein is compiled from a combination of historical reports and peer reviewed scientific publication manuscripts. Known mechanisms under which the fuel is susceptible to failure are highlighted and compared to conditions that could exist in the MARVEL reactor during an unanticipated transient or accident scenario. The two scenarios considered for analysis in this report are (1) an unprotected loss of flow accident and (2) a hypothetical unprotected loss of coolant accident during the loss of flow accident. Preliminary 2D steady-state analyses herein indicate that both fuel-cladding chemical interactions and fuel-cladding mechanical interactions are negligible throughout the fuel’s operational cycle under both normal and high temperature accident scenario conditions. Although higher fidelity 3D time-dependent modeling and simulations are planned, the following may be concluded presently. The MARVEL fuel element maintains its geometric stability and structural integrity during the most extreme accident scenarios predicted for the MARVEL reactor. The hoop stress during the unprotected loss of flow accident reaches about -1.27 MPa; this negative stress indicates that it is compressive rather than tensile. The compressive stress is a result of the NaK pressure on the outside of the fuel element, caused by the restricted thermal expansion of the NaK coolant, exceeding the internal pressures generated inside of the fuel element. The hoop stress generated in the cladding during the unprotected loss of coolant accident reaches a maximum of about approximately 10 MPa, which is nearly an order of magnitude less than the predicted yield strength of the cladding under high-temperature accident scenario conditions. Calculations were compared with results from high performance computational simulations using BISON and are in very close agreement. A conservative MARVEL fuel meat peak temperature limit of 900 °C is recommended presently, which is about 180 °C higher than the peak fuel temperature predicted to occur during the most extreme accident. Based on the known properties and behavior of the MARVEL fuel element, the fuel successfully meets its design and safety requirements under normal and most extreme accident conditions with a large safety margin.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modeling of Vertical Motor-driven Pump for Simulation of a Fault Signature \\ for Condition Monitoring

As part of the ongoing effort to transition from preventive maintenance strategies to condition-based maintenance strategies in nuclear power plants, there is significant reliance on using machine learning techniques. To develop a robust machine learning model that can diagnose all the fault modes of a vertical motor-driven pump, data capturing the unique signature of each fault mode is required. In practice, it is difficult to collect or capture data that captures all the fault modes from a single plant site. So to address this situation, a computational model of a vertical motor-driven pump is developed using the multipurpose finite element software COMSOL Multiphysics. The developed model is used to generate simulated data under normal operation and is compared with the vibration data collected using vibration sensors. Once the simulation model is verified under normal operating condition, simulated data for the fault mode for which minimal or no evidence is available in historical plant process data is developed. This simulated data is used to develop fault signatures to achieve robust predictive models. This paper presents modeling details and verification of the model that can used to generate data for fault modes that are not available at a plant site for condition monitoring purpose.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Modeling of Vertical Motor-driven Pump for Simulation of a Fault Signature \\ for Condition Monitoring

As part of the ongoing effort to transition from preventive maintenance strategies to condition-based maintenance strategies in nuclear power plants, there is significant reliance on using machine learning techniques. To develop a robust machine learning model that can diagnose all the fault modes of a vertical motor-driven pump, data capturing the unique signature of each fault mode is required. In practice, it is difficult to collect or capture data that captures all the fault modes from a single plant site. So to address this situation, a computational model of a vertical motor-driven pump is developed using the multipurpose finite element software COMSOL Multiphysics. The developed model is used to generate simulated data under normal operation and is compared with the vibration data collected using vibration sensors. Once the simulation model is verified under normal operating condition, simulated data for the fault mode for which minimal or no evidence is available in historical plant process data is developed. This simulated data is used to develop fault signatures to achieve robust predictive models. This paper presents modeling details and verification of the model that can used to generate data for fault modes that are not available at a plant site for condition monitoring purpose.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Detecting Process Equipment Failures Using Acoustic Data and Machine Learning

Nuclear power plant (NPP) process equipment such as fans, motors, valves, and pumps generate frequent or continuous noise, and deviations from the normal operational sounds made by this equipment can indicate potential issues. These deviations can be identified via automated acoustic anomaly detection, which involves using acoustic sensors (i.e., microphones) alongside detection algorithms to continuously monitor for changes in acoustic signatures. This task is made challenging by the substantial background noise that exists, such as operators opening and closing doors, manipulating valves, and conversing—in addition to typical plant noises. In collaboration with a nuclear power utility partner, this effort assessed the efficacy of acoustic anomaly detection when using a specific acoustic sensor that compresses data into a fixed set of features that are transferable over a standard Internet of Things communication protocol, thereby improving usability but potentially degrading detection performance. Two methods of performing automated acoustic anomaly detection were evaluated: one-class support vector machine (OC-SVM) and isolation forest (iForest). To enable the use of high-quality acoustic data encompassing both normal and anomalous conditions, the study utilized the publicly available Malfunctioning Industrial Machine Investigation and Inspection dataset, which includes real measured acoustic sensor data for a range of equipment types, model numbers, and signal-to-noise ratios (SNRs), along with a benchmark set of detection results. Using this dataset, the methods were tested and then compared against the benchmark results. The results indicated that although the specific acoustic sensor did not enable as rich a feature set extraction, the proposed methods with the limited feature set performed just as well. This provides solid justification for both the methods and the use of the proposed acoustic sensor.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Material Selection and Heat Transfer Model for PTUHS Device

The Path to Ultimate Heat Sink Device (PTUHS) is a passive safety system that utilizes a radiative heat transfer valve to control the rate at which heat is removed from a nuclear reactor pressure vessel (RPV) and dispersed into surrounding soil. The material selection for the PTUHS device is investigated, where the thermophysical properties are either maximized or minimized bases on what section of the PTUHS that material is being used for. Final recommendations of material choice are then presented. The heat transfer model of the PTUHS device is solved in ABAQUS, where a normal operating conditions and SCRAM conditions are solved. These temperature maps and heat flux of the system show the system's ability, where minimal heat is lost during normal operating conditions and system failure in a SCRAM scenario due to temperatures that were reached.

42 - ENGINEERING↗

From Obsolete to Optimal (ATR Demineralized Water System)

My project was migrating a Human-Machine Interface (HMI) and Programmable Logic Controller (PLC) program from legacy software to a modern platform, enhancing operational efficiency and eliminating unsupported, obsolete equipment. Initially, I used a migration tool to transfer the programs to the new software, then manually updated variables to align with the new PLC. I optimized the PLC code by leveraging new scaling features in the I/O cards, removing over 45 obsolete rungs, and enhancing clarity with functional tag aliases. Next, I modernized the HMI's visuals with an updated color scheme and 3D buttons. I developed multiple interface versions iteratively refining them based on operator feedback. I also designed and created a dedicated "Rounds" screen incorporating insights from a previous intern’s project to streamline daily rounds. To improve clarity, consistency, and efficiency I redesigned the entire interface. Adding visual indicators to enhance operational awareness: red is used for values outside normal specifications, green for normal operating modes, yellow for manual mode, and grey for offline units. Additionally, I added a dynamic visual representation of tank levels, creating PLC logic to show the level in inches as well as inches and feet. I then incorporated a navigation sidebar to facilitate efficient screen transitions. Risk of human error was mitigated by defining narrow input ranges for tank level shutoff and password protecting setpoint changes. I also fixed issues with datatypes that caused inaccuracies in the original code. Overall, this comprehensive upgrade significantly enhanced the HMI's functionality, user experience, and operational reliability.

47 - OTHER INSTRUMENTATION↗

Chemical Interaction of Palladium in Uranium Oxycarbide Nuclear Fuel Kernel

Chemical Interaction of Palladium in Uranium Oxycarbide Nuclear Fuel Kernel Jana Howard1,3, Guang Yang3, Haiyan Zhao1*, Patrick Warren4, Tiankai Yao3, Steven Cavazos4 Elizabeth Sooby Wood4*, Ching-heng Shiau2 1 University of Idaho, Environmental Science, Idaho Falls, Idaho, USA 2 Boise State University, Microscopy and Characterization Suite, Idaho Falls, Idaho, USA 3 Idaho National Laboratory, Idaho Falls, Idaho, USA 4 University of Texas San Antonio, Department of Physics and Astronomy, San Antonio, Texas, USA *Corresponding author: haiyanz@uidaho.edu; elizabeth.soobywood@utsa.edu Tri-structural Isotropic (TRISO) particle fuel is the preferred choice for the newest and next-generation high-temperature nuclear reactors due to its robust construction [1]. The fuel design effectively contains fission products inside the particle at extremely high temperatures [2]. However, the effect of transition metal fission products on fuel performance and structural integrity remains largely unknown, creating uncertainties in predicting fuel performance and potential failure mechanisms [2]. For example, palladium (Pd) has a strong tendency to form intermetallic phases with uranium (U). These new phases tend to be hard and brittle which could lead to fracture of fuel kernel during irradiation [3,4]. Pd is not normally produced in high concentrations in normal fission reactions however, driving the production of Pd into the locality of a Uranium Oxycarbide (UCO) nuclear fuel provides an opportunity to closely observe the diffusion and chemical interactions. This study focuses on detailed transmission electron microscopy characterization of the intermetallic phases formed by the interaction between a UCO kernel and a Pd bar after annealing at 1100 °C for 100 hours. Figure 1 provides an overview of the UCO kernel in contact with the Pd bar. The UCO-Pd sample surface was examined using a Focused Ion Beam (FIB) Quanta 3D FEG FEI in VCD detector mode at 10kV, 83pA to reveal surface features. Several key surface features in the interaction region were observed including: (1) a small area with dendritic microstructure, (2) color contrast near the UCO kernel and Pd boundary, and (3) darker and lighter regions throughout the sample surface. To analyze diffusion behavior, FIB was used to prepare lamellae from five different areas of the UCO-Pd sample, as well as one for the as-received sample. These lamellae were examined using a Scanning Transmission Electron Microscope ThermoFisher Spectra 300 (STEM-Spectra). Energy Dispersive Spectroscopy results confirmed the diffusion between the UCO fuel and Pd bar. Figure 2 shows the identified phases of UC, UO2, and Pd dispersed throughout the interaction region. It was also found that the Pd concentration decreases as the radial distance from the UCO-Pd interface increases. The Pd concentration was 36.93% atomic fraction 11µm from the interaction region then decreased to 7.51% atomic fraction at 257 µm away from the interaction region. Figure 3 shows how concentrations of U and Pd vary across the interaction zone, highlighting the extent of diffusion. This study confirms that Pd interacts with surrounding material to form U-Pd phase and diffusion zones. These diffusion zones vary in composition depending on its radial distance from the point of contact with the Pd bar. These findings contribute to a deeper understanding of the fission product behavior in high temperature nuclear fuels, aiding in the prediction and mitigation of potential fuel degradation mechanisms. A B C Fig. 1. SEM micrographs of UCO fuel kernel in contact with solid Pd bar and the lift out locations. Figure 1A shows UCO fuel kernel in contact with solid Pd bar. Figure 1B shows a higher magnification image of the UCO fuel-Pd interaction zone. Figure 1C shows lift out sites for the lamellae. A B C Fig 2. EDS maps reveal the distribution of U, O, and Pd in location 3. Figure 2A shows the distribution of uranium. Figure 2B shows the distribution of oxygen. Figure 2C shows the distribution of palladium. A B C Fig 3. Palladium and uranium concentration across interaction zone in location 2. Figure 3A shows EDS map of lift out number 2. Figure 3B shows a zoomed in EDS map taken from the interaction zone. Figure 3C shows a line graph of uranium and palladium concentrations across the interaction zone. References: 1. B.E. Wells, N.R. Phillips, K.J. Geelhood. Pacific West Laboratory. (2021). TRISO Fuel: Properties and Failure Modes. https://www.nrc.gov/docs/ML2117/ML21175A152.pdf (Accessed January 16, 2025). 2. American Nuclear Society. TRISO Fuel Development Progresses in INL, ORNL. https://www.gen-4.org/gif/upload/docs/application/pdf/2014-03/nov13nn_fuel_reprint.pdf (Accessed January 16, 2025) 3. Clark R.A., M.A. Con

36 - MATERIALS SCIENCE↗

Chemical Interaction of Palladium in Uranium Oxycarbide Nuclear Fuel Kernel

Chemical Interaction of Palladium in Uranium Oxycarbide Nuclear Fuel Kernel Jana Howard1,3, Guang Yang3, Haiyan Zhao1*, Patrick Warren4, Tiankai Yao3, Steven Cavazos4 Elizabeth Sooby Wood4*, Ching-heng Shiau2 1 University of Idaho, Environmental Science, Idaho Falls, Idaho, USA 2 Boise State University, Microscopy and Characterization Suite, Idaho Falls, Idaho, USA 3 Idaho National Laboratory, Idaho Falls, Idaho, USA 4 University of Texas San Antonio, Department of Physics and Astronomy, San Antonio, Texas, USA *Corresponding author: haiyanz@uidaho.edu; elizabeth.soobywood@utsa.edu Tri-structural Isotropic (TRISO) particle fuel is the preferred choice for the newest and next-generation high-temperature nuclear reactors due to its robust construction [1]. The fuel design effectively contains fission products inside the particle at extremely high temperatures [2]. However, the effect of transition metal fission products on fuel performance and structural integrity remains largely unknown, creating uncertainties in predicting fuel performance and potential failure mechanisms [2]. For example, palladium (Pd) has a strong tendency to form intermetallic phases with uranium (U). These new phases tend to be hard and brittle which could lead to fracture of fuel kernel during irradiation [3,4]. Pd is not normally produced in high concentrations in normal fission reactions however, driving the production of Pd into the locality of a Uranium Oxycarbide (UCO) nuclear fuel provides an opportunity to closely observe the diffusion and chemical interactions. This study focuses on detailed transmission electron microscopy characterization of the intermetallic phases formed by the interaction between a UCO kernel and a Pd bar after annealing at 1100 °C for 100 hours. Figure 1 provides an overview of the UCO kernel in contact with the Pd bar. The UCO-Pd sample surface was examined using a Focused Ion Beam (FIB) Quanta 3D FEG FEI in VCD detector mode at 10kV, 83pA to reveal surface features. Several key surface features in the interaction region were observed including: (1) a small area with dendritic microstructure, (2) color contrast near the UCO kernel and Pd boundary, and (3) darker and lighter regions throughout the sample surface. To analyze diffusion behavior, FIB was used to prepare lamellae from five different areas of the UCO-Pd sample, as well as one for the as-received sample. These lamellae were examined using a Scanning Transmission Electron Microscope ThermoFisher Spectra 300 (STEM-Spectra). Energy Dispersive Spectroscopy results confirmed the diffusion between the UCO fuel and Pd bar. Figure 2 shows the identified phases of UC, UO2, and Pd dispersed throughout the interaction region. It was also found that the Pd concentration decreases as the radial distance from the UCO-Pd interface increases. The Pd concentration was 36.93% atomic fraction 11µm from the interaction region then decreased to 7.51% atomic fraction at 257 µm away from the interaction region. Figure 3 shows how concentrations of U and Pd vary across the interaction zone, highlighting the extent of diffusion. This study confirms that Pd interacts with surrounding material to form U-Pd phase and diffusion zones. These diffusion zones vary in composition depending on its radial distance from the point of contact with the Pd bar. These findings contribute to a deeper understanding of the fission product behavior in high temperature nuclear fuels, aiding in the prediction and mitigation of potential fuel degradation mechanisms. A B C Fig. 1. SEM micrographs of UCO fuel kernel in contact with solid Pd bar and the lift out locations. Figure 1A shows UCO fuel kernel in contact with solid Pd bar. Figure 1B shows a higher magnification image of the UCO fuel-Pd interaction zone. Figure 1C shows lift out sites for the lamellae. A B C Fig 2. EDS maps reveal the distribution of U, O, and Pd in location 3. Figure 2A shows the distribution of uranium. Figure 2B shows the distribution of oxygen. Figure 2C shows the distribution of palladium. A B C Fig 3. Palladium and uranium concentration across interaction zone in location 2. Figure 3A shows EDS map of lift out number 2. Figure 3B shows a zoomed in EDS map taken from the interaction zone. Figure 3C shows a line graph of uranium and palladium concentrations across the interaction zone. References: 1. B.E. Wells, N.R. Phillips, K.J. Geelhood. Pacific West Laboratory. (2021). TRISO Fuel: Properties and Failure Modes. https://www.nrc.gov/docs/ML2117/ML21175A152.pdf (Accessed January 16, 2025). 2. American Nuclear Society. TRISO Fuel Development Progresses in INL, ORNL. https://www.gen-4.org/gif/upload/docs/application/pdf/2014-03/nov13nn_fuel_reprint.pdf (Accessed January 16, 2025) 3. Clark R.A., M.A. Con

36 - MATERIALS SCIENCE↗