Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Doxorubicin-Loaded QuadraSphere Microspheres: Plasma Pharmacokinetics and Intratumoral Drug Concentration in an Animal Model of Liver Cancer

The purpose of this study was to evaluate, in vitro and in vivo, doxorubicin-loaded poly (vinyl alcohol-sodium acrylate) copolymer microspheres [QuadraSphere microspheres (QSMs)] for transcatheter arterial delivery in an animal model of liver cancer. Doxorubicin loading efficiency and release profile were first tested in vitro. In vivo, 15 rabbits, implanted with a Vx-2 tumor in the liver, were divided into three groups of five rabbits each, based on the time of euthanasia. Twenty-five milligrams of QSMs was diluted in 10 ml of a 10 mg/ml doxorubicin solution and 10 ml of nonionic contrast medium for a total volume of 20 ml. One milliliter of a drug-loaded QSM solution containing 5 mg of doxorubicin was injected into the tumor feeding artery. Plasma doxorubicin and doxorubicinol concentrations, and intratumoral and peritumoral doxorubicin tissue concentrations, were measured. Tumor specimens were pathologically evaluated to record tumor necrosis. As a control, one animal was blandly embolized with plain QSMs in each group. In vitro testing of QSM doxorubicin loadability and release over time showed 82-94% doxorubicin loadability within 2 h and 6% release within the first 6 h after loading, followed by a slow release pattern. In vivo, the doxorubicin plasma concentration declined at 40 min. The peak doxorubicin intratumoral concentration was observed at 3 days and remained detectable till the study's end point (7 days). Mean percentage tumor cell death in the doxorubicin QSM group was 90% at 7 days and 60% in the bland QSM embolization group. In conclusion, QSMs can be efficiently loaded with doxorubicin. Initial experiments with doxorubicin-loaded QSMs show a safe pharmacokinetic profile and effective tumor killing in an animal model of liver cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ENHANCED DOE HIGH LEVEL WASTE MELTER THROUGHPUT STUDIES: SRNL GLASS SELECTION STRATEGY

The Department of Energy has authorized a team of glass formulation and processing experts at the Savannah River National Laboratory (SRNL), the Pacific Northwest National Laboratory (PNNL), and the Vitreous State Laboratory (VSL) at Catholic University of America to develop a systematic approach to increase high level waste melter throughput (by increasing waste loading with minimal or positive impacts on melt rate). This task is aimed at proof-of-principle testing and the development of tools to improve waste loading and melt rate, which will lead to higher waste throughput. Four specific tasks have been proposed to meet these objectives (for details, see WSRC-STI-2007-00483): (1) Integration and Oversight, (2) Crystal Accumulation Modeling (led by PNNL)/Higher Waste Loading Glasses (led by SRNL), (3) Melt Rate Evaluation and Modeling, and (4) Melter Scale Demonstrations. Task 2, Crystal Accumulation Modeling/Higher Waste Loading Glasses is the focus of this report. The objective of this study is to provide supplemental data to support the possible use of alternative melter technologies and/or implementation of alternative process control models or strategies to target higher waste loadings (WLs) for the Defense Waste Processing Facility (DWPF)--ultimately leading to higher waste throughputs and a reduced mission life. The glass selection strategy discussed in this report was developed to gain insight into specific technical issues that could limit or compromise the ability of glass formulation efforts to target higher WLs for future sludge batches at the Savannah River Site (SRS). These technical issues include Al-dissolution, higher TiO{sub 2} limits and homogeneity issues for coupled-operations, Al{sub 2}O{sub 3} solubility, and nepheline formation. To address these technical issues, a test matrix of 28 glass compositions has been developed based on 5 different sludge projections for future processing. The glasses will be fabricated and characterized based on the protocols outlined in the SRNL Task and Quality Assurance (QA) plan.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Condition Monitoring of Wind Turbine Planetary Gearboxes Under Different Operating Conditions

Digitally enhanced services for wind power could reduce Operations and Maintenance (O&M) costs as well as the Levelised Cost Of Energy (LCOE). Therefore, there is a continuous need for advanced monitoring techniques which can exploit the opportunities of Internet of Things (IoT) and Big Data Analytics, revolutionizing the future of the energy sector. The heart of wind turbines is a rather complex epicyclic gearbox. Among others, extremely critical gearbox components which are often responsible for machinery stops are the rolling element bearings. The vibration signatures of bearings are rather weak compared to other components, such as gears, and as a result an extended number of signal processing techniques and tools have been proposed during the last decades, focusing towards accurate, early, and on time bearing fault detection with limited false alarms and missed detections. Envelope Analysis is one of the most important methodologies, where an envelope of the vibration signal is estimated usually after filtering around a frequency band excited by impacts due to the bearing faults. Different tools, such as Kurtogram, have been proposed in order to accurately select the optimum filter parameters (center frequency and bandwidth). Cyclic Spectral Correlation and Cyclic Spectral Coherence, based on Cyclostationary Analysis, have been proved as very powerful tools for condition monitoring. The monitoring techniques seem to have reached a mature level in case a machinery operates under steady speed and load. On the other hand, in case the operating conditions change, it is still unclear whether the change of the monitoring indicators is due to the change of the health of the machinery or due to the change of the operating parameters. Recently, the authors have proposed a new tool called IESFOgram, which is based on Cyclic Spectral Coherence and can automatically select the filtering band. Furthermore, the Cyclic Spectral Coherence is integrated along the selected frequency band leading to an Improved Envelope Spectrum. In this paper, the performance of the tool is evaluated and further extended on cases operating under different speeds and different loads. The effectiveness of the methodology is tested and validated on the National Renewable Energy Laboratory (NREL) wind turbine gearbox vibration condition monitoring benchmarking data set which includes various faults with different levels of diagnostic complexity as well as various speed and load operating conditions.

17 WIND ENERGY↗

Field Trial of a Low-Cost, Distributed Plug Load Monitoring System

Researchers have struggled to inventory and characterize the energy use profiles of the ever-growing category of so-called miscellaneous electric loads (MELs) because plug-load monitoring is cost-prohibitive to the researcher and intrusive to the homeowner. However, these data represent a crucial missing link to understanding how homes use energy. Detailed energy use profiles would enable the nascent automated home energy management (AHEM) industry to develop effective control algorithms that target consumer electronics and other plug loads. If utility and other efficiency programs are to incent AHEM devices, they need large-scale datasets that provide statistically meaningful justification of their investments by quantifying the aggregate energy savings achievable. To address this need, NREL researchers investigated a variety of plug-load measuring devices available commercially and tested them in the laboratory to identify the most promising candidates for field applications. This report centers around the lessons learned from a field validation of one proof-of-concept system, called Smartenit (formerly SimpleHomeNet). The system was evaluated based on the rate of successful data queries, reliability over a period of days to weeks, and accuracy. This system offers good overall performance when deployed with up to 10 end nodes in a residential environment, although deployment with more nodes and in a commercial environment is much less robust. NREL concludes that the current system is useful in selected field research projects, with the recommendation that system behavior is observed over time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data Management for Digital Twin Implementation: Enhancing Existing SCADA Architecture for INL's CITRC Test Distribution System

The United States power grid will continue to experience stress from aging infrastructure, extreme weather, and increasing loads. In order to strengthen resiliency, researchers need to run tests and simulations that model real-life infrastructure. Idaho National Laboratory (INL) is creating a digital twin of its Critical Infrastructure Test Range Complex (CITRC). CITRC is an at-scale grid testbed which can be configured in utility-realistic distribution scenarios for a variety of tests, such as advanced grid protection and control. A digital twin of this infrastructure would support in-depth tests/simulations without risking physical consequences, before trialing devices under test at-scale. This project focuses on the data acquisition part of constructing a digital twin. It investigates the Supervisory Data Acquisition and Control (SCADA) system of CITRC and explores ways to utilize this system for the twin. Future “ideal” at-scale implementations such as upgraded equipment, modern communication protocols, and automation applications are also explored.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

RH Packaging Operations Manual (Rev. 3)

This procedure provides operating instructions for the remote-handled transuranic (RH-TRU) 72-B Cask Waste Shipping Package (hereinafter referred to as "72-B cask"). In this document, "Packaging" refers to the assembly of components necessary to ensure compliance with the packaging requirements (not loaded with a payload). "Package" refers to a Type B packaging that, with its radioactive contents, is designed to retain the integrity of its containment and shielding when subject to the normal conditions of transport and hypothetical accident test conditions set forth in 10 CFR Part 71. Before 72-B cask loading operations begin, loading procedures and revisions must be sent to the DOE Carlsbad Field Office (CBFO) at site.documents@wipp.ws for approval. Loading of the 72-B cask can be done one of two ways: on the cask trailer in the vertical position or by removing the cask from the trailer and loading it in an area designated for remote-handling. Two types of trailers were specially designed to transport the 72-B cask: a spread axle trailer requiring a crane to rotate the cask and a cask uprighting trailer designed with built-in hydraulics to rotate the 72-B cask into the vertical position while on the trailer. The hydraulic power unit is a separate piece of equipment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Field Trial of a Low-Cost, Distributed Plug Load Monitoring System

Researchers have struggled to inventory and characterize the energy use profiles of the ever-growing category of so-called miscellaneous electric loads (MELs) because plug-load monitoring is cost-prohibitive to the researcher and intrusive to the homeowner. However, these data represent a crucial missing link to our understanding of how homes use energy, and we cannot control what we do not understand. Detailed energy use profiles would enable the nascent automated home energy management (AHEM) industry to develop effective control algorithms that target consumer electronics and other plug loads. If utility and other efficiency programs are to incent AHEM devices, they need large-scale datasets that provide statistically meaningful justification of their investments by quantifying the aggregate energy savings achievable. To address this need, we have investigated a variety of plug-load measuring devices available commercially and tested them in the laboratory to identify the most promising candidates for field applications. The scope of this report centers around the lessons learned from a field validation of one proof-of-concept system, called Smartenit (formerly SimpleHomeNet). The system was evaluated based on the rate of successful data queries, reliability over a period of days to weeks, and accuracy. This system offers good overall performance when deployed with up to ten end nodes in a residential environment, although deployment with more nodes and in a commercial environment is much less robust. We conclude that the current system is useful in selected field research projects, with the recommendation that system behavior is observed over time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Condition Based Monitoring of Gas Turbine Combustion Components

The objective of this program is to develop sensors that allow condition based monitoring of critical combustion parts of gas turbines. Siemens teamed with innovative, small companies that were developing sensor concepts that could monitor wearing and cracking of hot turbine parts. A magnetic crack monitoring sensor concept developed by JENTEK Sensors, Inc. was evaluated in laboratory tests. Designs for engine application were evaluated. The inability to develop a robust lead wire to transmit the signal long distances resulted in a discontinuation of this concept. An optical wear sensor concept proposed by K Sciences GP, LLC was tested in proof-of concept testing. The sensor concept depended, however, on optical fiber tips wearing with the loaded part. The fiber tip wear resulted in too much optical input variability; the sensor could not provide adequate stability for measurement. Siemens developed an alternative optical wear sensor approach that used a commercial PHILTEC, Inc. optical gap sensor with an optical spacer to remove fibers from the wearing surface. The gap sensor measured the length of the wearing spacer to follow loaded part wear. This optical wear sensor was developed to a Technology Readiness Level (TRL) of 5. It was validated in lab tests and installed on a floating transition seal in an F-Class gas turbine. Laboratory tests indicate that the concept can measure wear on loaded parts at temperatures up to 800OC with uncertainty of < 0.3 mm. Testing in an F-Class engine installation showed that the optical spacer wore with the wearing part. The electro-optics box located outside the engine enclosure survived the engine enclosure environment. The fiber optic cable and the optical spacer, however, both degraded after about 100 operating hours, impacting the signal analysis.

42 ENGINEERING↗

HIGH ALUMINUM HLW GLASSES FOR HANFORDS WTP

The world's largest radioactive waste vitrification facility is now under construction at the United State Department of Energy's (DOE's) Hanford site. The Hanford Tank Waste Treatment and Immobilization Plant (WTP) is designed to treat nearly 53 million gallons of mixed hazardous and radioactive waste now residing in 177 underground storage tanks. This multi-decade processing campaign will be one of the most complex ever undertaken because of the wide chemical and physical variability of the waste compositions generated during the cold war era that are stored at Hanford. The DOE Office of River Protection (ORP) has initiated a program to improve the long-term operating efficiency of the WTP vitrification plants with the objective of reducing the overall cost of tank waste treatment and disposal and shortening the duration of plant operations. Due to the size, complexity and duration of the WTP mission, the lifecycle operating and waste disposal costs are substantial. As a result, gains in High Level Waste (HLW) and Low Activity Waste (LAW) waste loadings, as well as increases in glass production rate, which can reduce mission duration and glass volumes for disposal, can yield substantial overall cost savings. EnergySolutions and its long-term research partner, the Vitreous State Laboratory (VSL) of the Catholic University of America, have been involved in a multi-year ORP program directed at optimizing various aspects of the HLW and LAW vitrification flow sheets. A number of Hanford HLW streams contain high concentrations of aluminum, which is challenging with respect to both waste loading and processing rate. Therefore, a key focus area of the ORP vitrification process optimization program at EnergySolutions and VSL has been development of HLW glass compositions that can accommodate high Al{sub 2}O{sub 3} concentrations while maintaining high processing rates in the Joule Heated Ceramic Melters (JHCMs) used for waste vitrification at the WTP. This paper, reviews the achievements of this program with emphasis on the recent enhancements in Al{sub 2}O{sub 3} loadings in HLW glass and its processing characteristics. Glass formulation development included crucible-scale preparation and characterization of glass samples to assess compliance with all melt processing and product quality requirements, followed by small-scale screening tests to estimate processing rates. These results were used to down-select formulations for subsequent engineering-scale melter testing. Finally, further testing was performed on the DM1200 vitrification system installed at VSL, which is a one-third scale (1.20 m{sup 2}) pilot melter for the WTP HLW melters and which is fitted with a fully prototypical off-gas treatment system. These tests employed glass formulations with high waste loadings and Al{sub 2}O{sub 3} contents of {approx}25 wt%, which represents a near-doubling of the present WTP baseline maximum Al{sub 2}O{sub 3} loading. In addition, these formulations were processed successfully at glass production rates that exceeded the present requirements for WTP HLW vitrification by up to 88%. The higher aluminum loading in the HLW glass has an added benefit in that the aluminum leaching requirements in pretreatment are reduced, thus allowing less sodium addition in pretreatment, which in turn reduces the amount of LAW glass to be produced at the WTP. The impact of the results from this ORP program in reducing the overall cost and schedule for the Hanford waste treatment mission will be discussed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation of Mode I Notch Toughness of Zr{sub 41.2}Ti{sub 13.8}Cu{sub 10}Ni{sub 12.5}Be{sub 22.5} Metallic Glass under Dynamic Loading Conditions

Based on dynamic three-point bending tests, the dynamic notch toughness (K{sub Q}{sup d}) of Zr{sub 41.2}Ti{sub 13.8}Cu{sub 10}Ni{sub 12.5}Be{sub 22.5} (Vit 1) bulk metallic glass (BMG) was found to be sensitive to stress intensity factor rate ( K-dot {sub Q}{sup d}), which varied from 5.21 to 31.90 MPa m{sup 1/2}. The number of shear bands (N{sub s}) in the notch tip plastic zone was quantitatively analyzed. The phenomenon wherein N{sub s} decreased with increasing loading rate was explained based on the theory of the shear transformation zone and the softening mechanism. Then, power law relationships were established among N{sub s}, K{sub Q}{sup d} and K-dot {sub Q}{sup d}. The results showed that shear bands can affect K{sub Q}{sup d} and K-dot {sub Q}{sup d} and act as a bridge connecting K{sub Q}{sup d} and K-dot {sub Q}{sup d}. The sensitivity of K{sub Q}{sup d} to K-dot {sub Q}{sup d} in BMGs can be well explained by the variation of N{sub s} with loading rate.

36 MATERIALS SCIENCE↗

Dry Cask Shipments of ATR Spent Nuclear Fuel at INL

The High Load Charger (HLC) cask will be replacing the Advanced Test Reactor (ATR) spent fuel transfer cask that has been used at Idaho National Laboratory (INL) to wet-transfer spent ATR fuel elements from ATR to Idaho Nuclear Technology and Engineering Center (INTEC) in order to support future plans at both facilities. INTEC intends to discontinue use of the CPP-666 storage pools in compliance with the Idaho Settlement Agreement and the basins will no longer be available to store spent ATR fuel elements. In order to support the core-internals change out in 2021 for ATR, spent ATR fuel elements must be removed from the canal and shipped to INTEC. INL contractors will use the HLC cask for safe, dry transfer of spent Advanced Test Reactor (ATR) fuel elements between the ATR Complex managed by Battelle Energy Alliance, LLC and the Idaho Nuclear Technology and Engineering Center (INTEC) managed by Fluor Idaho, LLC. The HLC cask (also known as the High Load Charging Cask or High Load Charger) is a lead-shielded, stainless steel transfer container originally designed in 1954 by the Idaho Nuclear Corporation to meet the radiation and contamination controls requirements of the time for shipment of spent nuclear fuel. The cask has been modified over the years and is currently used for wet-to-dry transfers at INTEC. It is approved only for out-of-commerce transfers. The cask will arrive at the ATR where eight spent ATR fuel elements will be loaded into two, newly-designed buckets. Each bucket is a quarter section, right-cylinder shape that has four compartments. The cask will be lifted out of the ATR canal allowing most of the water to drain from the cask. Processing the 12,500 kg cask will be completed in ATR and then transported on a tractor trailer to INTEC where the loaded buckets will be removed from the cask. The loaded buckets will undergo a drying process before placing the four buckets into a canister for long-term storage in the Irradiated Fuel Storage Facility (IFSF) at INTEC. A new transportation plan that was submitted to, and approved by, the U.S. Department of Energy to provide the cask safety basis, which describes the hazard analysis and accident analysis for the cask during transport. Supporting accident analysis include criticality, thermal, dose, and drop analyses. Of particular interest for this cask was the drop analysis from which was derived the speed limit for the transport. The drop analysis addressed drops in air onto an unyielding surface and in water onto an energy-absorbing pad for the cask in the ATR facility. These analyses are typically applied as the bounding drop scenarios during transport; however, this resulted in a safety basis speed limit of 12.9 kph. In order to more accurately represent the in-transit accident scenario, LS-DYNA software was procured and the model was updated to more closely represent the potential drop heights and impact surfaces of asphalt and soil for the cask while in transit. This analysis resulted in a safety basis speed limit of 48 kph. This safety basis speed limit is more practical to implement and control.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Wind-induced torsion of parabolic trough collectors in operation

Parabolic trough collector (PTC) systems, a type of concentrating solar power (CSP), use parabolic mirrors to reflect the sun's rays toward an absorber tube to heat the fluid inside. PTCs track the sun throughout the day and are sensitive to angular misalignment, which reduces optical performance. Torsion of the PTC, exacerbated by wind loading, contributes to angular misalignment, which has been quantified by previous studies using numerical simulations and experimental tests. However, angular misalignment due to torsion and wind loading has not yet been studied in an operational plant, which can experience more extreme and variable conditions. This study characterizes the angular misalignment due to torsion at three rows of the Nevada Solar One CSP plant and investigates the influence of wind loading. These findings reveal substantial torsion along the PTC support structure that depends on wind conditions and orientation. Strong winds perpendicular to the PTCs increase the median angular displacement of the outermost row by up to 18 mrad and increase the standard deviation by up to 8 mrad when compared to weak wind conditions. These findings can inform enhanced PTC design, controls and modeling that will improve the performance, reliability and bankability of future CSP plants.

14 SOLAR ENERGY↗

Extending the range of constant strain rate nanoindentation testing

Constant strain rate nanoindentation hardness measurements at high sustained strain rates cannot be made in conventional nanoindentation testing systems using the commonly employed continuous stiffness measurement technique (CSM) because of the “plasticity error” recently reported by Merle et al. [Acta Mater.134, 167 (2017)]. To circumvent this problem, here we explore an alternative testing and analysis procedure based on quasi-static loading and an independent knowledge of the Young's modulus, which is easily obtained by standard nanoindentation testing. In theory, the method applies to any indentation strain rate, but in practice, an upper limit on the rate arises from hardware limitations in the testing system. The new methodology is developed and applied to measurements made with an iMicro nanoindenter (KLA, Inc.), in which strain rates up to 100 s -1 were successfully achieved. The origins of the hardware limitations are documented and discussed.

36 MATERIALS SCIENCE↗

Finite element analyses of continuous filament ties for masonry applications : final report for the Arquin Corporation.

Finite-element analyses were performed to simulate the response of a hypothetical vertical masonry wall subject to different lateral loads with and without continuous horizontal filament ties laid between rows of concrete blocks. A static loading analysis and cost comparison were also performed to evaluate optimal materials and designs for the spacers affixed to the filaments. Results showed that polypropylene, ABS, and polyethylene (high density) were suitable materials for the spacers based on performance and cost, and the short T-spacer design was optimal based on its performance and functionality. Simulations of vertical walls subject to static loads representing 100 mph winds (0.2 psi) and a seismic event (0.66 psi) showed that the simulated walls performed similarly and adequately when subject to these loads with and without the ties. Additional simulations and tests are required to assess the performance of actual walls with and without the ties under greater loads and more realistic conditions (e.g., cracks, non-linear response).

42 ENGINEERING↗

Spent Nuclear Fuel Mechanical Loads in the General Package Drop Scenario

The US Department of Energy Spent Fuel and Waste Science and Technology program is performing research to determine the mechanical loading conditions applied to spent nuclear fuel (SNF) during normal conditions of transportation to inform mechanical tests of SNF and close an important knowledge gap related to the practical disposition of SNF in the US. A recent multi-national collaborative test campaign measured SNF assembly impact response to the 30 cm horizontal package drop scenario, which is a common regulatory basis test of SNF package design. Researchers at Pacific Northwest National Laboratory (PNNL) are using the test data to validate explicit finite element models to calculate the mechanical loads and structural response of spent nuclear fuel assemblies in the as-tested 30 cm horizontal package drop scenario. Once the as-tested package drop model is validated, the next step is to apply the model to the general 30 cm drop scenario, which includes all impact angles, all fuel assembly types, and all burnup conditions. PNNL is developing a damage model that will incorporate the results of finite element parametric studies to establish trends in SNF mechanical loading to various input parameters, like impact orientation and burnup. The damage model will have the capability to estimate mechanical loads for any single set of input parameters, but it will first be used to describe the upper bounds of potential SNF loading in the 30 cm drop scenario. This paper describes PNNL’s progress toward developing the general solution to the problem of spent nuclear fuel mechanical loads in the 30 cm package drop scenario and it describes the next steps in closing the knowledge gap.

Klymyshyn, Nicholas A.↗

China Energy Efficiency Round Robin Testing Results for Room Air Conditioners

In recent years China's energy consumption has increased rapidly. The problem of high energy consumption intensity and low energy utilization efficiency is serious, and the contradiction between economic development and energy and environmental resources has become increasingly acute, making energy conservation and consumption reduction an important society-wide concern. At the same time, global climate change has and will continue to have profound impacts on human survival and development, and is another major challenge to all countries. In order to accelerate China's energy conservation and emission reduction work, the National Leading Group to Address Climate Change, Energy Conservation and Emission Reduction was founded with Premier Wen Jiabao as the head, and the 'Comprehensive Work Program of Energy Conservation and Emission Reduction' and 'China's National Program of Addressing Climate Change' were issued, under which China's energy conservation and emission reduction work has been fully deployed. Efforts to promote energy efficiency have been further strengthened in all levels of government, and various policies and measures have progressively been issued and implemented. In addition, based on China's experience with implementing energy-saving priority strategies over the past 20+ years, our government established a goal of a 20% decrease in energy consumption per unit GDP in the 'Eleventh Five-year Development Plan'. Furthermore, in November 2009, in order to support global greenhouse gas emission reduction activities and promote China's low carbon economic development, the government established a further 40-50% reduction in energy consumption per unit GDP by 2020 compared to the year 2005. Improving energy utilization efficiency by scientific and technological progress will undoubtedly play an important role in achieving the above stated objectives. The improvement of energy efficiency of energy consuming products has always been an important component of all countries energy strategies. As we all know, a very large amount of total energy consumption is due to energy consuming products and equipment, which account for about 50% of China's total energy consumption. However, the current average energy utilization efficiency of this sector is only about 60%, 10 percent lower than the international advanced level. Therefore, China's energy consuming products and equipment sector holds great energy-saving potential. On the other hand, the energy supplied to these products is mainly from fossil fuel combustion, a major source of greenhouse gas (GHG) emissions. Therefore, improving the energy efficiency and augmenting the market share of market-dominant energy consuming products is of significant importance to achieving China's energy saving and emission reduction target and is an effective means to deal with energy and environmental constraints and climate change issues. Main energy consuming products generally include widely-used home appliances, industrial equipment, office equipment, transportation vehicles, etc. China is one of the major manufacturers and exporters of energy end-using products such as air-conditioners, refrigerators, televisions, etc. Their overall energy efficiency is comparatively low and the products are poorly designed, leading to great energy-saving potential. For example, electricity consumption of air conditioners accounts for about 20% of China's total electricity consumption and 40% of the summer electricity peak load in large and medium cities. However, less than 5% of units sold in the domestic market in 2009 reached the standard's highly efficient level of grade 2 above. The electricity consumption of electric motors and their related drive systems accounts for about 60% of China's total electricity consumption; however, less than 2% of the domestic market share consists of energy-efficient electric motor products. Promoting the energy efficiency and market shares of main energy-consuming products has become an important determinant of achieving energy conservation and emission reduction targets throughout the world.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Real-Time Dynamic Brake Assessment Proof of Concept Final Report

This proof-of-concept research was performed to explore the feasibility of using real-world braking data from commercial motor vehicles to make a diagnosis of brake condition similar to that of the performance-based brake tester (PBBT). This was done by determining the relationship between pressure and brake force (P-BF), compensating for the gross vehicle weight (GVW). The nature of this P-BF relationship (e.g., low braking force for a given brake application pressure) may indicate brake system problems. In order to determine the relationship between brake force and brake application pressure, a few key parameters of duty cycle information were collected. Because braking events are often brief, spanning only a few seconds, a sample rate of 10 Hz was needed. The algorithm under development required brake application pressure and speed (from which deceleration was calculated). Accurate weight estimation was also needed to properly derive the braking force from the deceleration. In order to ensure that braking force was the predominant factor in deceleration for the segments of data used in analysis, the data was screened for grade as well. Also, the analysis needed to be based on pressures above the crack pressure. The crack pressure is the pressure below which the individual brakes are not applied due the nature of the mechanical system. This value, which may vary somewhat from one wheel end to another, is approximately 10 psi. Therefore, only pressures 15 psi and above were used in the analysis. The Department of Energy s Medium Truck Duty Cycle research has indicated that under the real-world circumstances of the test vehicle brake pressures of up to approximately 30 psi can be expected. Several different types of data were collected during the testing task of this project. Constant-pressure stopping tests were conducted at several combinations of brake application pressure (15, 20, 25, and 30 psi), load conditions (moderately and fully laden), and speeds (20 and 30 mph). Data was collected at 10 Hz. Standard and stepped-pressure performance-based brake tests with brake pressure transducers were performed for each loading condition. The stepped-pressure test included the constant-pressure intervals of brake application at 15, 20, 25, and 30 psi. The PBBT data files included 10 Hz streaming data collected during the testing of each axle. Two weeks of real-world duty cycle (driving and braking) data was also collected at 10 Hz. Initial analysis of the data revealed that the data collected in the field (i.e., day-to-day operations) provided the same information as that obtained from the controlled tests. Analysis of the data collected revealed a strong linear relationship between brake application pressure and deceleration for given GVWs. As anticipated, initial speed was not found to be a significant factor in the deceleration-pressure relationship, unlike GVW. The positive results obtained from this proof of concept test point to the need for further research to expand this concept. A second phase should include testing over a wider range of speeds and include medium brake application pressures in addition to the low pressures tested in this research. Testing on multiple vehicles would also be of value. This future phase should involve testing to determine how degradation of braking performance affects the pressure-deceleration relationship.

99 GENERAL AND MISCELLANEOUS↗

Levelized cost of charging of extreme fast charging with stationary LMO/LTO batteries

Extreme DC fast charging for electric vehicles (EVs) could be competitive with the internal combustion engine refueling experience and enable longer-distance travel, which could help with EV adoption and decarbonization, but these systems have high capital costs and extremely variable high-power demands. Behind-the-meter systems (BTMS) could support extreme-fast-charging (XFC) stations to increase nationwide adoption of EVs. Here, this study examines the optimal break-even levelized cost of charging (LCOC) across 96 BTMS scenarios to enable low-wait XFC stations providing 200 miles of charge in 10 min. This research simulates LCOC via synthetic XFC-capable EV loads, machine-learned battery life models from testing data, and nonlinear optimal controls, co-minimizing complex utility costs and battery replacements. An aggregate optimal BTMS design treating each EV load as equal likely gives an optimal LCOC per utility rate, the average of which is $\$$0.59/kWh. In addition, the sensitivity of optimal and off-optimal design factors, the long-life LMO/LTO chemistry, and optimized controls are analyzed. The battery control model, based on battery stressors to compare chemistries, optimizes LMO/LTO resting state of charge and cycle depth without compromising cost reduction, which enables greater flexibility in operation. The LCOC savings due to replacement reduction are small, up to $\$$0.035/kWh (6%), with an average of $\$$0.02/kWh (3.5%). Compared with gasoline stations, the aggregate XFC station design achieves comparable speed, experience of service, and cost at $\$$3.81/gal gasoline, showing that EVs can replace gasoline vehicles even for longer-distance travel.

25 ENERGY STORAGE↗