Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

An Optical Streaking Method for Measuring Femtosecond Electron Bunches

The measurement of the ultra-short electron bunch length on the femtosecond time scale constitutes a very challenging problem. In the x-ray free electron laser facilities such as the Linac Coherent Light Source, generation of a sub-ten femtoseconds electron beam with 20pC charge is possible, but direct measurements are very difficult due to the resolution limit of the present diagnostics. We propose a new method here based on the measurement of the electron beam energy modulation induced from laser-electron interaction in a short wiggler. A typical optical streaking method requires a laser wavelength much longer than the electron bunch length. In this paper a laser with its wavelength shorter than the electron bunch length has been adopted, while the slope on the laser intensity envelope is used to distinguish the different periods. With this technique it is possible to reconstruct the bunch longitudinal profile from a single shot measurement. Generation of ultrashort x-ray pulses at femtoseconds (fs) scale is of great interest within synchrotron radiation and free electron laser (FEL) user community. One of the simple methods is to operate the FEL facility at low charge. At the Linac Coherent Light Source (LCLS), we have demonstrated the capability of generating ultrashort electron-beam (e-beam) with a duration of less than 10 fs fwhm using 20 pC charge. The x-ray pulses have been delivered to the x-ray users with a similar or even shorter pulse duration. However, The measurement of such short electron or x-ray pulse length at the fs time-scale constitutes a challenging problem. A standard method using an S-band radio-frequency (rf) transverse deflector has been established at LCLS, which works like a streak camera for electrons and is capable of resolving bunch lengths as short as 25 fs fwhm. With this device, the electrons are transversely deflected by the high-frequency time-variation of the deflecting fields. Increasing the deflecting voltage and rf frequency are the right direction to achieve a better resolution. For example, by choosing an X-band transverse deflecting cavity, the expected resolution for LCLS beam with 4.3 GeV is about 1 fs rms. Typically the rf breakdown threshold and the power source availability prevent going to even higher voltage and frequency. With the highly-developed laser techniques, we can choose to streak the beam at optical frequencies. By jumping from rf to optical frequency, the wavelength is shortening by 4 to 5 orders. With an electron bunch length shorter than half period of the laser, we can apply the similar rf deflecting or zero-phasing method for e-beam bunch length measurements using a high-power laser. A short wiggler is required to provide interaction between the electron and the laser. For example, to measure the e-beam at the order of 1 m rms length, a laser with its wavelength of 10 {mu}m may be considered. For a typical few GeV e-beam, the wiggler period has to be large to satisfy the resonance condition. Also, if the e-beam is longer than one laser period, the different modulation periods will overlap and we cannot distinguish them. So this method is so far limited by the achievable long-wavelength laser power. To get an effective modulation on an e-beam of 4.3 GeV, the required laser power is about a few tens GW. In this paper we propose to adopt a high-power Ti:Sapphire laser (wavelength of 800 nm), and use the slope in the intensity envelope to distinguish the different modulation periods. First an ultrashort electron beam interacts with the Ti:Sapphire laser in a wiggler, where the electron energy is modulated at the same periods of the laser. If the laser pulse is long and the short electron bunch is overlapped (in time) with the middle part of the laser, such as the setup at LCLS laser heater, the different energy modulation periods on the electron beam will be overlapped on the energy profile. In this conditionwe typically have a double-horn distribution of the energy profile, and the electron-bunch length information cannot be retrieved. But if the laser pulse (with a Gaussian temporal shape) is relatively short, we can synchronize the e-beam with the laser at the slope region of the intensity envelope, and the amplitude of each energy modulation period will be different. Then these electrons pass through a dispersive section such as a spectrometer, after that this periodically-modulated energy profile can be observed in a transverse screen. By properly choosing the laser parameters, each modulation period will show as a separate streak on the screen. This modulation period in energy dimension correlates to the laser wavelength in time dimension. Since the laser wavelength is a known parameter, no additional calibration is needed. This provides a single shot, self-calibrated method for ultrashort electron bunch length measurements.

43 PARTICLE ACCELERATORS↗

Combining experiment and optical simulation in coherent X-ray nanobeam characterization of Si/SiGe semiconductor heterostructures

The highly coherent and tightly focused x-ray beams produced by hard x-ray light sources enable the nanoscale characterization of the structure of electronic materials but are accompanied by significant challenges in the interpretation of diffraction and scattering patterns. X-ray nanobeams exhibit optical coherence combined with a large angular divergence introduced by the x-ray focusing optics. The scattering of nanofocused x-ray beams from intricate semiconductor heterostructures produces a complex distribution of scattered intensity. We report here an extension of coherent x-ray optical simulations of convergent x-ray beam diffraction patterns to arbitrary x-ray incident angles to allow the nanobeam diffraction patterns of complex heterostructures to be simulated faithfully. These methods are used to extract the misorientation of lattice planes and the strain of individual layers from synchrotron x-ray nanobeam diffraction patterns of Si/SiGe heterostructures relevant to applications in quantum electronic devices. The systematic interpretation of nanobeam diffraction patterns from semiconductor heterostructures presents a new opportunity in characterizing and ultimately designing electronic materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Combining X-ray Absorption and X-ray Diffraction Techniques for in Situ Studies of Chemical Transformations in Heterogeneous Catalysis:Advantages and Limitations

Recent advances in catalysis instrumentations include synchrotron-based facilities where time-resolved X-ray scattering and absorption techniques are combined in the same in situ or operando experiment to study catalysts at work. To evaluate the advances and limitations of this method, we performed a series of experiments at the new XAFS/XRD instrument in the National Synchrotron Light Source. Nearly simultaneous X-ray diffraction (XRD) and X-ray absorption fine-structure (XAFS) measurements of structure and kinetics of several catalysts under reducing or oxidizing conditions have been performed and carefully analyzed. For CuFe{sub 2}O{sub 4} under reducing conditions, the combined use of the two techniques allowed us to obtain accurate data on kinetics of nucleation and growth of metallic Cu. For the inverse catalyst CuO/CeO{sub 2} that underwent isothermal reduction (with CO) and oxidation (with O{sub 2}), the XAFS data measured in the same experiment with XRD revealed strongly disordered Cu species that went undetected by diffraction. These and other examples emphasize the unique sensitivity of these two complementary methods to follow catalytic processes in the broad ranges of length and time scales.

43 PARTICLE ACCELERATORS↗

Final Report on the Joule-Scale Experimental Demonstration

We describe the final results of the High Power Laser Pulse Recirculation project. We have developed and implementing a novel technique for picosecond, Joule-class laser pulse recirculation inside a passive cavity. The aim of this project was to develop technology compatible with increasing the efficiency of Compton based light sources by more than an order of magnitude. In year 1 of the project, we achieved a greater than 40 times average power enhancement of the mJ-scale laser pulses inside a passive cavity with internal focus. In year 2, we demonstrated recirculation of lasers pulses with energies up to 191 mJ at 532 nm, at a repetition rate of 10 Hz, and a pulse duration of 20 ps. In this high energy regime, we achieved up to 14 times average power enhancement inside the cavity. This enhancement factor is compatible with the new X-band based mono-energetic gamma-ray machine, Velociraptor, being constructed at LLNL. The demonstrated cavity enhancement is primarily limited by the poor spatial beam quality of the high power laser beam. We expect a nearly diffraction limited laser beam to achieve 40 times or better cavity enhancement, as demonstrated in low energy experiments in FY-07. The two primary obstacles to higher average brightness and conversion efficiency of laser pulse energy to gamma-rays are the relatively small Compton scattering cross-section and the typically low repetition rates of Joule-class interaction lasers (10 Hz). Only a small fraction (10{sup -10}) of the available laser photons is converted to gamma-rays, while the rest is discarded. To significantly reduce the average power requirements of the laser and increase the overall system efficiency, we can recirculate laser light for repeated interactions with electron bunches. Our pulse recirculation scheme is based on nonlinear frequency conversion, termed recirculation injection by nonlinear gating (RING), inside a passive cavity. The main objectives of the two year project were: (1) Validate the concept of RING pulse trapping and recirculation technique. Completed Sep. 07 (2) Develop cavity designs compatible with a laser-electron Compton light source. Completed January 08. (3) Demonstrate trapping and recirculation of laser pulses suitable for high brightness gamma-ray generation. Completed Aug. 08 Our project has established RING as a viable technology for enhancing Compton scattering based gamma-ray generation. With sufficient funding we can implement pulse recirculation on the next generation Mono-energetic Gamma-Ray machine under construction at LLNL.

42 ENGINEERING↗

Simulations of in situ x-ray diffraction from uniaxially compressed highly textured polycrystalline targets

A growing number of shock compression experiments, especially those involving laser compression, are taking advantage of in situ x-ray diffraction as a tool to interrogate structure and microstructure evolution. Although these experiments are becoming increasingly sophisticated, there has been little work on exploiting the textured nature of polycrystalline targets to gain information on sample response. Here, we describe how to generate simulated x-ray diffraction patterns from materials with an arbitrary texture function subject to a general deformation gradient. We will present simulations of Debye-Scherrer x-ray diffraction from highly textured polycrystalline targets that have been subjected to uniaxial compression, as may occur under planar shock conditions. In particular, we study samples with a fibre texture, and find that the azimuthal dependence of the diffraction patterns contains information that, in principle, affords discrimination between a number of similar shock-deformation mechanisms. For certain cases, we compare our method with results obtained by taking the Fourier transform of the atomic positions calculated by classical molecular dynamics simulations. Illustrative results are presented for the shock-induced α–ϵ phase transition in iron, the α–ω transition in titanium and deformation due to twinning in tantalum that is initially preferentially textured along [001] and [011]. The simulations are relevant to experiments that can now be performed using 4th generation light sources, where single-shot x-ray diffraction patterns from crystals compressed via laser-ablation can be obtained on timescales shorter than a phonon period.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Determination of X-ray flux using silicon pin diodes

Accurate measurement of photon flux from an X-ray source, a parameter required to calculate the dose absorbed by the sample, is not yet routinely available at macromolecular crystallography beamlines. The development of a model for determining the photon flux incident on pin diodes is described here, and has been tested on the macromolecular crystallography beamlines at both the Swiss Light Source, Villigen, Switzerland, and the Advanced Light Source, Berkeley, USA, at energies between 4 and 18 keV. These experiments have shown that a simple model based on energy deposition in silicon is sufficient for determining the flux incident on high-quality silicon pin diodes. The derivation and validation of this model is presented, and a web-based tool for the use of the macromolecular crystallography and wider synchrotron community is introduced.

absorbed dose↗

Repeatability and sensitivity characterization of the far-field high-energy diffraction microscopy instrument at the Advanced Photon Source

In the last two decades, far-field high-energy diffraction microscopy (FF-HEDM) and similar non-destructive techniques have been actively developed at synchrotron light sources around the world. As these techniques (and associated analysis tools) are becoming more available for the general users of these light sources, it is important and timely to characterize their performance and capabilities. In this work, the FF-HEDM instrument implemented at the 1-ID-E endstation of the Advanced Photon Source (APS) is summarized. The set of measurements conducted to characterize the instrument's repeatability and sensitivity to changes in grain orientation and position are also described. When an appropriate grain matching method is used, the FF-HEDM instrument's repeatability is approximately 5 µm in translation, 0.02° in rotation, and 2 × 10 −4 in strain; the instrument sensitivity is approximately 5 µm in translation and 0.05° in rotation.

3DXRD↗

Aperture alignment in autocollimator-based deflectometric profilometers

During the last ten years, deflectometric profilometers have become indispensable tools for the precision form measurement of optical surfaces. They have proven to be especially suitable for characterizing beam-shaping optical surfaces for x-ray beamline applications at synchrotrons and free electron lasers. Deflectometric profilometers use surface slope (angle) to assess topography and utilize commercial autocollimators for the contactless slope measurement. To this purpose, the autocollimator beam is deflected by a movable optical square (or pentaprism) towards the surface where a co-moving aperture limits and defines the beam footprint. In this paper, we focus on the precise and reproducible alignment of the aperture relative to the autocollimator's optical axis. Its alignment needs to be maintained while it is scanned across the surface under test. The reproducibility of the autocollimator's measuring conditions during calibration and during its use in the profilometer is of crucial importance to providing precise and traceable angle metrology. In the first part of the paper, we present the aperture alignment procedure developed at the Advanced Light Source, Lawrence Berkeley National Laboratory, USA, for the use of their deflectometric profilometers. In the second part, we investigate the topic further by providing extensive ray tracing simulations and calibrations of a commercial autocollimator performed at the Physikalisch-Technische Bundesanstalt, Germany, for evaluating the effects of the positioning of the aperture on the autocollimator's angle response. The investigations which we performed are crucial for reaching fundamental metrological limits in deflectometric profilometry.

47 OTHER INSTRUMENTATION↗

Color Choice is Everything - Impacts Color makes to the Lighting Environment

When contracts are let out to design multiple systems in a vehicle, it is a challenge to maintain integration between system leads. Designers on niche systems, like lighting and control panel design, often get caught up in the challenge of designing the light source or visual interface and fail to include time in their schedule to work with system architects on how their lighting system will be integrated. Additionally, behavioral scientists, industrial designers, and materials engineers get caught up with the materials and look of the system, but often fail to consider how the selection of their materials could affect the certification or performance of electronic devices like lighting systems. Additionally, computer modeling of the system architecture often assumes a perfect environment without the clutter of actual human use (dirt, stowage, crowding). As a result, lighting systems, and backlit displays run the risk of being overdesigned or under designed. Engineers making the assumption that because they have no input or there is no requirement on work surface reflectance, make the assumption that they can t count on good material choices and thus may install more lighting than is necessary. While having more lights may seem better, for a vehicle that is trying to conserve power, more lights may not be a good option. On the other hand, designers who made the opposite assumption and designed a lighting system that only produced just enough light, often wind up with a system that did conserve power, but didn t produce enough light. These situations are exasperated when the system starts to be used and the models are not perfect anymore. The lack of coordination and iterative design not only can impact lighting levels within an environment, but also can affect color perception. This is because, if materials do not represent a gradation of white or black, the material unevenly absorbs and reflects light at different wavelengths of the visual spectrum. The lighting designer may have built a light that meets light spectra requirements, but the eventual light reaching the human user may not be the spectra of light architects intended, if materials near the light source change the spectrum just by how much color is absorbed or reflected. With the recent findings concerning Circadian rhythm, where the spectra of light is extremely important for addressing crew sleep and wake cycles, system architects should pay considerable attention on the impact material choices have in changing the light spectrum in an environment. This presentation will show examples of how material choices impact the resulting illuminance, color spectrum, and power usage of an illuminated space. Its goal is to encourage system designers and planners to use more care in development of requirements and the verification of systems intended for the human visual interface.

Clark, Toni A.↗

The Effect of Incident Light Polarization on Vegetation Bidirectional Reflectance Factor

The Laboratory-based Bidirectional Reflectance Factor (BRF) polarization study of vegetation is presented in this paper. The BRF was measured using a short-arc Xenon lamp/monochromator assembly producing an incoherent, tunable light source with a well-defined spectral bandpass at visible and near-infrared wavelengths of interest at 470 nm and 870 nm and coherent light source at 1.656 microns. All vegetation samples were measured using P and S linearly polarized incident light over a range of incident and scatter angles. By comparing these results, we quantitatively examine how the BRF of the samples depends on the polarization of the incident light. The differences are significant, depend strongly on the incident and scatter angles, and can be as high as 120% at 67 deg incident and 470nm. The global nature of Earth's processes requires consistent long-term calibration of all instruments involved in data retrieval. The BRF defines the reflection characteristics of Earth surface. It provides the reflectance of a target in a specific direction as a function of illumination and viewing geometry. The BRF is a function of wavelength and reflects the structural and optical properties of the surface. Various space and airborne radiometric and imaging remote sensing instruments are used in the remote sensing characterization of vegetation canopies and soils, oceans, or especially large pollution sources. The satellite data is validated through comparison with airborne, ground-based and laboratory-based data in an effort to fully understand the vegetation canopy reflectance, The Sun's light is assumed to be unpolarized at the top of the atmosphere; however it becomes polarized to some degree due to atmospheric effects by the time it reaches the vegetation canopy. Although there are numerous atmospheric correction models, laboratory data is needed for model verification and improvement.

Georgiev, Georgi T.↗

Apparatus for Direct Optical Fiber Through-Lens Illumination of Microscopy or Observational Objects

In one embodiment of the invention, a microscope or other observational apparatus, comprises a hollow tube, a lens mounted to the tube, a light source and at least one flexible optical fiber having an input end and an output end. The input end is positioned to receive light from the light source, and the output end is positioned within the tube so as to directly project light along a straight path to the lens to illuminate an object to be viewed. The path of projected light is uninterrupted and free of light deflecting elements. By passing the light through the lens, the light can be diffused or otherwise defocused to provide more uniform illumination across the surface of the object, increasing the quality of the image of the object seen by the viewer. The direct undeflected and uninterrupted projection of light, without change of direction, eliminates the need for light-deflecting elements, such as beam-splitters, mirrors, prisms, or the like, to direct the projected light towards the object.

Kadogawa, Hiroshi↗

Low-Charge, Hard X-Ray Free Electron Laser Driven with an X-Band Injector and Accelerator

After the successful operation of the Free Electron Laser in Hamburg (FLASH) and the Linac Coherent Light Source (LCLS), soft and hard x-ray free electron lasers (FELs) are being built, designed, or proposed at many accelerator laboratories. Acceleration employing lower frequency rf cavities, ranging from L-band to C-band, is usually adopted in these designs. In the first stage bunch compression, higher-frequency harmonic rf system is employed to linearize the beam's longitudinal phase space, which is nonlinearly chirped during the lower frequency rf acceleration process. In this paper, a hard x-ray FEL design using an all X-band accelerator at 11.424 GHz (from photocathode rf gun to linac end) is presented, without the assistance of any harmonic rf linearization. It achieves LCLS-like performance at low charge using X-band linac drivers, which is more versatile, efficient, and compact than ones using S-band or C-band rf technology. It employs initially 42 microns long (rms), low-charge (10 pC) electron bunches from an X-band photoinjector. An overall bunch compression ratio of roughly 100 times is proposed in a two stage bunch compressor system. The start-to-end macroparticle 3D simulation employing several computer codes is presented in this paper, where space charge, wakefields, and incoherent and coherent synchrotron radiation effects are included. Employing an undulator with a short period of 1.5 cm, a Genesis FEL simulation shows successful lasing at a wavelength of 0.15 nm with a pulse length of 2 fs and a power saturation length as short as 20 meters, which is equivalent to LCLS low-charge mode. Its overall length of both accelerators and undulators is 180 meters (much shorter than the effective LCLS overall length of 1230 meters, including an accelerator length of 1100 meters and an undulator length of 130 meters), which makes it possible to be built in places where only limited space is available.

43 PARTICLE ACCELERATORS↗

Silicon-Phosphorene Nanocavity-Enhanced Optical Emission at Telecommunications Wavelengths

Generating and amplifying light in silicon (Si) continues to attract significant attention due to the possibility of integrating optical and electronic components in a single material platform. Unfortunately, silicon is an indirect band gap material and therefore an inefficient emitter of light. With the rise of integrated photonics, the search for silicon-based light sources has evolved from a scientific quest to a major technological bottleneck for scalable, CMOS-compatible, light sources. Recently, emerging two-dimensional materials have opened the prospect of tailoring material properties based on atomic layers. Few-layer phosphorene, which is isolated through exfoliation from black phosphorus (BP), is a great candidate to partner with silicon due to its layer-tunable direct band gap in the near-infrared where silicon is transparent. Here we demonstrate a hybrid silicon optical emitter composed of few-layer phosphorene nanomaterial flakes coupled to silicon photonic crystal resonators. We show single-mode emission in the telecommunications band of 1.55 μm ($E_g$ = 0.8 eV) under continuous wave optical excitation at room temperature. The solution-processed few-layer BP flakes enable tunable emission across a broad range of wavelengths and the simultaneous creation of multiple devices. Our work highlights the versatility of the Si-BP material platform for creating optically active devices in integrated silicon chips.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Characterization of groove density variation of VLS gratings with ALS XROL LTP-II in different operation modes

The long trace profiler, LTP-II, available at the Advanced Light Source (ALS) X-ray Optics Laboratory (XROL), was recently upgraded by replacing a multimode diode laser light source with a single-mode, wavelength-stabilized, fibercoupled diode laser system. The upgrade enables us to reliably characterize the lateral variation of groove density of variable-line-spacing (VLS) x-ray diffraction gratings. Here, we discuss the LTP-II performance with an example of measurements with a VLS grating with the groove density at the grating center of 300 lines/mm. For the measurements, we use the LTP-II in two different operation arrangements, the single Gaussian beam and the pencil beam interferometer arrangements. For each operation arrangement, we apply two data processing algorithms: with calculating the centroid position and with determining the position of a characteristic features of the detected beam intensity distributions. Additionally, we discuss the observed strong correlation between the LTP-II modes of operation and the resulted (extracted) groove density variations. We also speculate on possible origin of the correlation.

42 ENGINEERING↗

Initial test bed concentrator characterization

The operational characteristics and the mirror alignment technique of the test bed concentrator control system are highlighted. The final design of the TBC control system provided one axis of fast slew capability so that either the Sun acquisition or emergency off-Sun mode could be obtained in a minimum time. The procedure for getting on and off Sun is to run the elevation axis up to the approximate elevation of the Sun for the particular time of acquisition and then slew the concentrator on Sun in azimuth. The automatic Sun-acquisition system is controlled by two Sun sensors, one for each axis; each has a 2deg acquisition cone angle within which the concentrators are programmed to point. The mirror alignment technique chosen utilized a semi-distant incandescent light source which produced a reflected image on the focal point target. The concentrator was boresighted to the light by moving the concentrator while sighting along the cross hairs and through the apertures in the disks to the light source resulting in a maximum point error of 0.11 deg. Test plans to install a solar flux mapper to characterize the solar spot and to measure the size, shape, and intensity of the Sun's image are outlined.

Starkey, D. J.↗

Hardware and Methods of the Optical End-to-End Test of the Far Ultraviolet Spectroscopic Explorer (FUSE)

The Far Ultraviolet Spectroscopic Explorer (FUSE), currently being tested and scheduled for a 1999 launch, is an astrophysics satellite designed to provide high spectral resolving power (Lambda/(Delta)Lambda = 24,000-30,000) over the interval 90.5-118.7 nm. The FUSE optical path consists of four co-aligned, normal incidence, off-axis parabolic, primary mirrors which illuminate separate Rowland circle spectrograph channels equipped with holographic gratings and delay line microchannel plate detectors. We describe the hardware and methods used for the optical end-to-end test of the FUSE instrument during satellite integration and test. Cost and schedule constraints forced us to devise a simplified version of the planned optical test which occurred in parallel with satellite thermal-vacuum testing. The optical test employed a collimator assembly which consisted of four co-aligned, 15" Cassegrain telescopes which were positioned above the FUSE instrument, providing a collimated beam for each optical channel. A windowed UV light source, remotely adjustable in three axes, was mounted at the focal plane of each collimator. Problems with the UV light sources, including high F-number and window failures, were the only major difficulties encountered during the test. The test succeeded in uncovering a significant problem with the secondary structure used for the instrument closeout cavity and, furthermore, showed that the mechanical solution was successful. The hardware was also used extensively for simulations of science observations, providing both UV light for spectra and visible light for the fine error sensor camera.

Conard, Steven J.↗

Identifying Longitudinal Jitter Sources in the LCLS Linac

The Linac Coherent Light Source (LCLS) at SLAC is an x-ray Free Electron Laser (FEL) with wavelengths of 0.15 nm to 1.5 nm. The electron beam stability is important for good lasing. While the transverse jitter of the beam is about 10-20% of the rms beam sizes, the jitter in the longitudinal phase space is a multiple of the energy spread and bunch length. At the lower energy of 4.3 GeV (corresponding to the longest wavelength of 1.5 nm) the relative energy jitter can be 0.125%, while the rms energy spread is with 0.025% five times smaller. An even bigger ratio exists for the arrival time jitter of 50 fs and the bunch duration of about 5 fs (rms) in the low charge (20 pC) operating mode. Although the impact to the experiments is reduced by providing pulse-by-pulse data of the measured energy and arrival time, it would be nice to understand and mitigate the root causes of this jitter. The thyratron of the high power supply of the RF klystrons is one of the main contributors. Another suspect is the multi-pacting in the RF loads. Phase measurements down to 0.01 degree (equals 10 fs) along the RF pulse were achieved, giving hints to the impact of the different sources.

43 PARTICLE ACCELERATORS↗

Fluorescence strobo-stereoscopy for specular reflection-suppressed full field of view imaging

This report introduces fluorescence strobo-stereoscopy (FSS) to suppress strong specular reflection and enable the full field of view (FFOV) 3D surface imaging while the part is rotating. Specular reflection off the target surface significantly degrades the image quality and becomes critical for highly reflective surface measurements. In FSS, the fluorescent dye-doped fluid applied on the machined surface is excited upon incident ultra-violet light and becomes a new light source by Stokes' Law. Thus, specular reflection off of smooth surface can be suppressed by separating the fluorescent light from the excitation light. The developed FSS comprises a pair of imaging cameras, spatial filters, and an excitation light source. As a result, FSS effectively rejected the specular reflection and improved the FFOV 3D surface image quality of the machined part by enhancing contrast in the rotating target surface. Such enhancements in 3D imaging allowed to identify manufacturing tolerance of the part and to detect the surface features. The axial and lateral accuracy errors of FSS were 2.3% and 1.4% with the target size of 4.07 mm and 0.215 mm, respectively. A whole view reconstruction of the cylindrical target sample was performed, and the corresponding cylindricity and diameter deviation were assessed. The fluid media effect and the target surface quality effect were discussed.

3D surface imaging↗