Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light pulses”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Optical techniques for time and frequency transfer

Light has been used as a means for time synchronization for a long time. The flight time was supposed to be negligible. The first scientific determination of the velocity of the light was done by measuring a round trip flight time on a given distance. The well known flying clock experiment leading to Einstein's General Relativity is another example. The advent of lasers, particularly short pulse and modulated ones, as well as the improvements of the timing equipments have led to new concepts for time and frequency transfer. We describe some experiments using different techniques and configurations which have been proposed and tested in this field since the beginning of the space age. Added to that, we set out advantages, drawbacks, and performances achieved in the different cases.

Baumont, Francoise↗

Fiber-Optic Pressure Sensor With Dynamic Demodulation Developed

Researchers at the NASA Glenn Research Center developed in-house a method to detect pressure fluctuations using a fiber-optic sensor and dynamic signal processing. This work was in support of the Intelligent Systems Controls and Operations project under NASA's Information Technology Base Research Program. We constructed an optical pressure sensor by attaching a fiber-optic Bragg grating to a flexible membrane and then adhering the membrane to one end of a small cylinder. The other end of the cylinder was left open and exposed to pressure variations from a pulsed air jet. These pressure variations flexed the membrane, inducing a strain in the fiber-optic grating. This strain was read out optically with a dynamic spectrometer to record changes in the wavelength of light reflected from the grating. The dynamic spectrometer was built in-house to detect very small wavelength shifts induced by the pressure fluctuations. The spectrometer is an unbalanced interferometer specifically designed for maximum sensitivity to wavelength shifts. An optimum pathlength difference, which was determined empirically, resulted in a 14-percent sensitivity improvement over theoretically predicted path-length differences. This difference is suspected to be from uncertainty about the spectral power difference of the signal reflected from the Bragg grating. The figure shows the output of the dynamic spectrometer as the sensor was exposed to a nominally 2-kPa peak-to-peak square-wave pressure fluctuation. Good tracking, sensitivity, and signal-to-noise ratios are evident even though the sensor was constructed as a proof-of-concept and was not optimized in any way. Therefore the fiber-optic Bragg grating, which is normally considered a good candidate as a strain or temperature sensor, also has been shown to be a good candidate for a dynamic pressure sensor.

Lekki, John D.↗

Tunable Optical True-Time Delay Devices Would Exploit EIT

Tunable optical true-time delay devices that would exploit electromagnetically induced transparency (EIT) have been proposed. Relative to prior true-time delay devices (for example, devices based on ferroelectric and ferromagnetic materials) and electronically controlled phase shifters, the proposed devices would offer much greater bandwidths. In a typical envisioned application, an optical pulse would be modulated with an ultra-wideband radio-frequency (RF) signal that would convey the information that one seeks to communicate, and it would be required to couple differently delayed replicas of the RF signal to the radiating elements of a phased-array antenna. One or more of the proposed devices would be used to impose the delays and/or generate the delayed replicas of the RF-modulated optical pulse. The beam radiated or received by the antenna would be steered by use of a microprocessor-based control system that would adjust operational parameters of the devices to tune the delays to the required values. EIT is a nonlinear quantum optical interference effect that enables the propagation of light through an initially opaque medium. A suitable medium must have, among other properties, three quantum states (see Figure 1): an excited state (state 3), an upper ground state (state 2), and a lower ground state (state 1). These three states must form a closed system that exhibits no decays to other states in the presence of either or both of two laser beams: (1) a probe beam having the wavelength corresponding to the photon energy equal to the energy difference between states 3 and 1; and (2) a coupling beam having the wavelength corresponding to the photon energy equal to the energy difference between states 3 and 2. The probe beam is the one that is pulsed and modulated with an RF signal.

Kulikov, Igor↗

High Harmonic Generation Seeding Echo-Enabled Harmonic Generation toward a Storage Ring-Based Tender and Hard X-ray-Free Electron Laser

To align with the global trend of integrating synchrotron light source (SLS) and free electron laser (FEL) facilities on one site, in line with examples such as SPring-8 and SACLA in Japan and ELETTRA and FERMI in Italy, we actively explore FEL options leveraging the ultralow-emittance electron beam of the NSLS-II upgrade. These options show promising potential for synergy with storage ring (SR) operations, thereby significantly enhancing our facility’s capabilities. Echo-enabled harmonic generation (EEHG) is well-suited to SR-based FELs, and has already been demonstrated with the capability of generating extremely narrow bandwidth as well as high brightness, realized using diffraction-limited short pulses in transverse planes and Fourier transform-limited bandwidth in the soft X-ray spectrum. However, regarding a conventional EEHG scheme, the combination of the shortest seed laser wavelength (256 nm) and highest harmonic (200) sets the short wavelength limit to λ = 1.28 nm. To further extend the short wavelength limit down to the tender and hard X-ray region, a vital option is to shorten the seed laser wavelength. Thanks to recent advances in high harmonic generation (HHG), packing 10 9 photons at one harmonic within a few-femtosecond pulse could turn such a novel HHG source into an ideal seeding for EEHG. Thus, compared to the cascaded EEHG, the HHG seeding option could not only lower the cost, but also free the SR space for accommodating more user beamlines. Moreover, to mitigate the SASE background noise on the sample and detector, we combine the HHG seeding EEHG with the crab cavity short pulse scheme for maximum benefit.

36 MATERIALS SCIENCE↗

Coupled order parameters and photoinduced domain walls in the charge density wave of (TaSe 4 ) 2 I

The charge density wave in (TaSe 4 ) 2 I has drawn much attention recently as a controversial candidate for an axion insulator where the CDW breaks the chiral symmetry of the Weyl semimetal. Here we use ultrafast x-ray scattering to study the collective modes of this CDW. By measuring several diffraction peaks we find that the order parameter involves coupled optical and acoustic modes. For strong near-infrared excitation, the dynamics of the x-ray diffraction show evidence of photoinduced inversion of both components of the CDW order parameter, and associated domain walls. These results demonstrate the potential of ultrafast methods to induce topological defects through highly nonequilibrium dynamics. In (TaSe 4 ) 2 I these defects should lead to exotic electronic states due to the nontrivial topology of the band structure.

36 MATERIALS SCIENCE↗

Performance of large-scale 6 Li-doped pulse-shape discriminating plastic scintillators

A 6 Li-doped plastic scintillator with pulse-shape discrimination capabilities, commercially identified as EJ -299-50, has been developed and produced at the kilogram-scale. A total of 44 bars of dimensions 5.5 cm x 5.5 cm x 50 cm of this material have been characterized. Optical properties like light output and effective attenuation length have been found to be comparable to 6 Li-doped liquid scintillators. Further, the scintillator EJ -299-50 shows good neutron detection capabilities with an effective efficiency for capture on 6 Li of approximately 85%. Stability tests performed on two formulation variations showed no intrinsic degradation in the material or optical properties during several months of observations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring a Fiber-Optic Delay Line Using a Mode-Locked Laser

The figure schematically depicts a laboratory setup for determining the optical length of a fiber-optic delay line at a precision greater than that obtainable by use of optical time-domain reflectometry or of mechanical measurement of length during the delay-line-winding process. In this setup, the delay line becomes part of the resonant optical cavity that governs the frequency of oscillation of a mode-locked laser. The length can then be determined from frequency-domain measurements, as described below. The laboratory setup is basically an all-fiber ring laser in which the delay line constitutes part of the ring. Another part of the ring - the laser gain medium - is an erbium-doped fiber amplifier pumped by a diode laser at a wavelength of 980 nm. The loop also includes an optical isolator, two polarization controllers, and a polarizing beam splitter. The optical isolator enforces unidirectional lasing. The polarization beam splitter allows light in only one polarization mode to pass through the ring; light in the orthogonal polarization mode is rejected from the ring and utilized as a diagnostic output, which is fed to an optical spectrum analyzer and a photodetector. The photodetector output is fed to a radio-frequency spectrum analyzer and an oscilloscope. The fiber ring laser can generate continuous-wave radiation in non-mode-locked operation or ultrashort optical pulses in mode-locked operation. The mode-locked operation exhibited by this ring is said to be passive in the sense that no electro-optical modulator or other active optical component is used to achieve it. Passive mode locking is achieved by exploiting optical nonlinearity of passive components in such a manner as to obtain ultra-short optical pulses. In this setup, the particular nonlinear optical property exploited to achieve passive mode locking is nonlinear polarization rotation. This or any ring laser can support oscillation in multiple modes as long as sufficient gain is present to overcome losses in the ring. When mode locking is achieved, oscillation occurs in all the modes having the same phase and same polarization. The frequency interval between modes, often denoted the free spectral range (FSR), is given by c/nL, where c is the speed of light in vacuum, n is the effective index of refraction of the fiber, and L is the total length of optical path around the ring. Therefore, the length of the fiber-optic delay line, as part of the length around the ring, can be calculated from the FSRs measured with and without the delay line incorporated into the ring. For this purpose, the FSR measurements are made by use of the optical and radio-frequency spectrum analyzers. In experimentation on a 10-km-long fiber-optic delay line, it was found that this setup made it possible to measure the length to within a fractional error of about 3 10(exp -6), corresponding to a length error of 3 cm. In contrast, measurements by optical time-domain reflectometry and mechanical measurement were found to be much less precise: For optical time-domain reflectometry, the fractional error was found no less than 10(exp -4) (corresponding to a length error of 1 m) and for mechanical measurement, the fractional error was found to be about 10(exp -2) (corresponding to a length error of 100 m).

Tu, Meirong↗

Uncovering extreme nonlinear dynamics in solids through time-domain field analysis

Time-domain analysis of harmonic fields with sub-cycle resolution is now experimentally viable due to the emergence of sensitive, on-chip techniques for petahertz-scale optical-field sampling. We demonstrate how such a time-domain, field-resolved analysis uncovers the extreme nonlinear electron dynamics responsible for high-harmonic generation within solids. Time-dependent density functional theory was used to simulate harmonic generation from a solid-state band-gap system driven by near- to mid-infrared waveforms. Particular attention was paid to regimes where both intraband and interband emission mechanisms play a critical role in shaping the nonlinear response. We show that a time-domain analysis of the harmonic radiation fields identifies the interplay between intra- and interband dynamical processes underlying the nonlinear light generation. With further analysis, we show that changes to the dominant emission regime can occur after only slight changes to the peak driving intensity and central driving wavelength. Furthermore, time-domain analysis of harmonic fields also reveals, for the first time, the possibility of rapid changes in the dominant emission mechanism within the temporal window of the driving pulse envelope. Finally, we examine the experimental viability of performing time-domain analysis of harmonic fields with sub-cycle resolution using realistic parameters.

74 ATOMIC AND MOLECULAR PHYSICS↗

An improved light source for laser ranging

The development of a new laser material, Cr-doped LiSAF, makes possible the development of a laser source for satellite ranging systems that is more superior in performance capabilities than current Nd:YAG-based laser sources. This new material offers the potential of shorter pulses and more preferable wavelengths (850 and 425 nm) than multiwavelength Nd:YAG systems, leading to superior ranging resolution and greater detection sensitivity. We are embarking on a feasibility study of a two-wavelength, mode-locked laser system based on Cr:LiSAF, providing shorter pulses for improved ranging resolution.

Hamal, Karel↗

SO2 Spectroscopy with A Tunable UV Laser

A portion of the fluorescence spectrum of SO2 has been studied using a narrow wavelength doubled dye laser as the exciting source. One purpose of this study is to evaluate the use of SO2 resonance re-emission as a probe of SO2 in the atmosphere. When the SO2 is excited by light at 300.2 nm, for example, a strong reemission peak is observed which is Stokes-shifted from the incident light wavelength by the usual Raman shift (the VI symmetric vibration frequency 1150.5/cm ). The intensity of this peak is sensitive to small changes (.01 nm) in the incident wavelength. Measurements of the N2 quenching and self quenching of this re-emission have been obtained. Preliminary analysis of this data indicates that the quenching is weak but not negligible. The dye laser in our system is pumped by a pulsed N2 laser. Tuning 'and spectral narrowing are accomplished using a telescope-echelle grating combination. In a high power configuration the resulting pulses have a spectral width of about 5 x 10(exp -3) nm and a time duration of about 6 nsec. The echelle grating is rotated by a digital stepping motor, such that each step shifts the wavelength by 6 x 10(exp -4) nm. In addition to the tunable, narrow wavelength uv source and spectral analysis of the consequent re-emission, the system also provides time resolution of the re-emitted light to 6 nsec resolution. This capability is being used to study the lifetime of low pressure S02 fluorescence at different wavelengths and pressures.

Morey, W. W.↗

Direct evidence of the effect of a moderate external magnetic field on stimulated Raman scattering in the kinetic regime

We present results from an experiment carried out at the OMEGA-EP laser facility that investigated the effect of a perpendicular magnetic field on stimulated Raman scattering (SRS) and report the first direct measurement of magnetic mitigation of SRS. A 13-T magnetic field generated by pulsed-power coils was imposed on a gas jet plasma, and a novel three-picket interaction beam was used to explore SRS reflectivity for several plasma conditions within single shots. The time-resolved backscattered light shows that SRS was mitigated by the external 13-T magnetic field in the kinetic regime (kλ D ∼ 0.3, where k is the electron plasma wave's wavenumber and λ D is electron Debye length) and at a density of n e /n cr ∼ 0.10. On the other hand, we also measured an enhancement of SRS reflectivity at lower density (n e /n cr < 0.08). We discuss experimental results in the context of magnetohydrodynamic and particle-in-cell simulations that scan SRS dynamics for a variety of plasma conditions. While the experimental evidence of SRS mitigation validates prior work on the kinetic simulation of SRS in an external magnetic field, we also find that other mechanisms such as SRS rescatter can lead to an enhancement of measured SRS reflectivity in simulations of parameters relevant to our experiment.

Gas jet↗

Mass-dependent channel electron multiplier operation

The absolute counting efficiency and pulse height distributions of a continuous-channel electron multiplier used in the detection of hydrogen, argon and xenon ions are assessed. The assessment technique, which involves the post-acceleration of 8-eV ion beams to energies from 100 to 4000 eV, provides information on counting efficiency versus post-acceleration voltage characteristics over a wide range of ion mass. The charge pulse height distributions for H2 (+), A (+) and Xe (+) were measured by operating the experimental apparatus in a marginally gain-saturated mode. It was found that gain saturation occurs at lower channel multiplier operating voltages for light ions such as H2 (+) than for the heavier ions A (+) and Xe (+), suggesting that the technique may be used to discriminate between these two classes of ions in electrostatic analyzers.

Fields, S. A.↗

Soft x-ray properties of the binary millisecond pulsar J0437-4715

We obtained a light curve for the 5.75 ms pulsar J0437-4715 in the 65-120 A range with 0.5 ms time resolution using the Deep Survey instrument on the EUVE satellite. The single-peaked profile has a pulsed fraction of 0. 27 +/- 0.05, similar to the ROSAT data in the overlapping energy band. A combined analysis of the EUVE and ROSAT data is consistent with a power-law spectrum of energy index alpha = 1.2-1.5, intervening column density NH = (5-8) x 10(exp 19)/sq cm, and luminosity 5.0 x 10(exp 30) ergs/s in the 0.1-2. 4 keV band. We also use a bright EUVE/ROSAT source only 4.3 deg from the pulsar, the Seyfert galaxy RX J0437.4-4711 (= EUVE J0437-471 = lES 0435-472), to obtain an independent upper limit on the intervening absorption to the pulsar, NH less than 1.2 x 10(exp 20)/sq cm. Although a blackbody spectrum fails to fit the ROSAT data, two-component spectral fits to the combined EUVE/ROSAT data are used to limit the temperatures and surface areas of thermal emission that might make partial contributions to the flux. A hot polar cap of radius 50-600 m and temperature (1.0-3.3) x 10(exp 6) K could be present. Alternatively, a larger region with T = (4-12) x 10(exp 5) K and area less than 200 sq km, might contribute most of the EUVE and soft X-ray flux, but only if a hotter component were present as well. Any of these temperatures would require some mechanism(s) of surface reheating to be operating in this old pulsar, the most plausible being the impact of accelerated electrons and positrons onto the polar caps. The kinematically corrected spin-down power of PSR J0437-4715 is only 4 x 10(exp 33) ergs/s, which is an order of magnitude less than that of the lowest-luminosity gamma-ray pulsars Geminga and PSR B1055-52. The absence of high-energy gamma-rays from PSR J0437-4715 might signify an inefficient or dead outer gap accelerator, which in turn accounts for the lack of a more luminous reheated surface such as those intermediate-age gamma-ray pulsars may have.

Halpern, Jules P.↗

Soft X-Ray Properties of the Binary Millisecond Pulsar J0437-4715

We obtained a light curve for the 5.75 ms pulsar J0437-4715 in the 65-120 A range with 0.5 ms time resolution using the Deep Survey instrument on the EUVE satellite. The single-peaked profile has a pulsed fraction of 0.27 +/- 0.05, similar to the ROSAT data in the overlapping energy band. A combined analysis of the EUVE and ROSAT data is consistent with a power-law spectrum of energy index alpha = 1.2 - 1.5, intervening column density N(sub H) = (5 - 8) x 10(exp 19)/sq cm, and luminosity 5.0 x 10(exp 30) ergs/s in the 0.1 - 2.4 keV band. We also use a bright EUVE/ROSAT source only 4.2 min. from the pulsar, the Seyfert galaxy RX J0437.4-4711 (= EUVE J0437-471 = IES 0435-472), to obtain an independent upper limit on the intervening absorption to the pulsar, N(sub H) less than 1.2 x 10(exp 20)/sq cm. Although a blackbody spectrum fails to fit the ROSAT data, two-component spectral fits to the combined EUVE/ROSAT data are used to limit the temperatures and surface areas of thermal emission that might make partial contributions to the flux. A hot polar cap of radius 50 - 600 m and temperature (1.0 - 3.3) x 10(exp 6) K could be present. Alternatively, a larger region with T = (4 - 12) x 10(exp 5) K and area less than 200 sq km, might contribute most of the EUVE and soft X-ray flux, but only if a hotter component were present as well. Any of these temperatures would require some mechanism(s) of surface reheating to be operating in this old pulsar, the most plausible being the impact of accelerated electrons and positrons onto the polar caps. The kinematically corrected spin-down power of PSR J0437-4715 is only 4 x 10(exp 33) ergs/s, which is an order of magnitude less than that of the lowest-luminosity gamma-ray pulsars Geminga and PSR B1055-52. The absence of high-energy gamma-rays from PSR J0437-4715 might signify an inefficient or dead outer gap accelerator, which in turn accounts for the lack of a more luminous reheated surface such as those intermediate-age gamma-ray pulsars may have.

Halpern, Jules P.↗

Constraints on the Emission and Viewing Geometry of the Transient Anomalous X-ray Pulsar XTE J1810-197

The temporal decay of the flux components of the transient anomalous X-ray pulsar XTE J1 810-197 following its 2002 outburst presents a unique opportunity to probe the emission geometry of a magnetar. Toward this goal, we model the magnitude of the pulsar's modulation in narrow spectral bands over time. Following previous work, we assume that the postoutburst flux is produced in two distinct thermal components arising from a hot spot and a warm concentric ring. We include general relativistic effects on the blackbody spectra due to gravitational redshift and light bending near the stellar surface, which strongly depend on radius. This affects the model fits for the temperature and size of the emission regions. For the hot spot, the observed temporal and energy-dependent pulse modulation is found to require an anisotropic, pencil-beamed radiation pattern. We are able to constrain an allowed range for the angles that the line of sight (psi) and the hot spot pole (xi) make with respect to the spin axis. Within errors, this is defined by the locus of points in the xi-psi plane that lie along the line [xi + beta(R)] [psi + [beta(R)] = const, where beta(R) is a function of the radius R of the star. For a canonical value of R = 12 km, the viewing parameters range from psi = xi = 37deg to (psi, xi) = (85deg, 15deg). We discuss our results in the context of magnetar emission models.

Perna, Rosalba↗

Nonlinear reversal of photoexcitation on the attosecond time scale improves ultrafast X-ray diffraction images

The complex refractive index of a material governs its light-matter interactions, with intense light fields enabling tailored nonlinear optical responses. In the X-ray regime, rapid photoionization limits the potential of nonlinear techniques by inducing irreversible electronic damage. Here we demonstrate that intense, sub-femtosecond X-ray pulses, shorter than typical Auger decay times, can partially reverse photoexcitation via stimulated emission near atomic resonances. By analyzing thousands of coherent diffraction patterns and ion spectra from neon nanoparticles exposed to sub-fs and 15-fs pulses, we observe enhanced X-ray diffraction alongside reduced energy absorption for sub-fs pulses. Theoretical modeling attributes this to dynamics akin to Rabi flopping that prolong the lifetime of resonant states and suppress electronic bleaching. These findings suggest that ultrashort, intense X-ray pulses enable active control of X-ray refractive index and damage pathways, opening avenues for improved high-resolution imaging and nonlinear spectroscopy in complex nanoscale systems.

Ulmer, Anatoli [Universität Hamburg (Germany)] (OR↗

Radiation-induced reaction kinetics of Zn 2+ with e S - and Cl 2 ˙ - in Molten LiCl–KCl eutectic at 400–600 °C

We report molten chloride salts are currently under consideration as combined coolant and liquid fuel for next-generation molten salt nuclear reactors. Unlike complementary light-water reactor technologies, the radiation science underpinning molten salts is in its infancy, and thus requires a fundamental mechanistic investigation to elucidate the radiation-driven chemistry within molten salt reactors. Here we present an electron pulse radiolysis kinetics study into the behaviour of the primary radiolytic species generated in molten chloride systems, i.e., the solvated electron (e S - ) and di-chlorine radical anion (Cl 2 ˙- ). We examine the reaction of e S - with Zn 2+ from 400–600 °C (E a = 30.31 ± 0.09 kJ mol -1 ), and the kinetics and decay mechanisms of Cl 2 ˙- in molten lithium chloride-potassium chloride (LiCl–KCl) eutectic. In the absence of Zn 2+ , the lifetime of e S - was found to be dictated by residual impurities in ostensibly “pure” salts, and thus the observed decay is dependent on sample history rather than being an intrinsic property of the salt. The decay of Cl 2 ˙- is complex, owing to the competition of Cl 2 ˙- disproportionation with several other chemical pathways, one of which involves reduction by radiolytically-produced Zn + species. Overall, the reported findings demonstrate the richness and complexity of chemistry involving the interactions of ionizing radiation with molten salts.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Advanced Water Vapor Lidar Detection System

In the present water vapor lidar system, the detected signal is sent over long cables to a waveform digitizer in a CAMAC crate. This has the disadvantage of transmitting analog signals for a relatively long distance, which is subjected to pickup noise, leading to a decrease in the signal to noise ratio. Generally, errors in the measurement of water vapor with the DIAL method arise from both random and systematic sources. Systematic errors in DIAL measurements are caused by both atmospheric and instrumentation effects. The selection of the on-line alexandrite laser with a narrow linewidth, suitable intensity and high spectral purity, and its operation at the center of the water vapor lines, ensures minimum influence in the DIAL measurement that are caused by the laser spectral distribution and avoid system overloads. Random errors are caused by noise in the detected signal. Variability of the photon statistics in the lidar return signal, noise resulting from detector dark current, and noise in the background signal are the main sources of random error. This type of error can be minimized by maximizing the signal to noise ratio. The increase in the signal to noise ratio can be achieved by several ways. One way is to increase the laser pulse energy, by increasing its amplitude or the pulse repetition rate. Another way, is to use a detector system with higher quantum efficiency and lower noise, on the other hand, the selection of a narrow band optical filter that rejects most of the day background light and retains high optical efficiency is an important issue. Following acquisition of the lidar data, we minimize random errors in the DIAL measurement by averaging the data, but this will result in the reduction of the vertical and horizontal resolutions. Thus, a trade off is necessary to achieve a balance between the spatial resolution and the measurement precision. Therefore, the main goal of this research effort is to increase the signal to noise ratio by a factor of 10 over the current system, using a newly evaluated, very low noise avalanche photo diode detector and constructing a 10 MHz waveform digitizer which will replace the current CAMAC system.

Elsayed-Ali, Hani↗