Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

MO-DE-206-03: Quantifying Metabolism with Hyperpolarized MR

In this symposium jointly sponsored by the World Molecular Imaging Society (WMIS) and the AAPM, luminary speakers on imaging metabolism will discuss three impactful topics. The first presentation on Cellular Metabolism of FDG will be given by Guillem Pratx (Stanford). This presentation will detail new work on looking at how the most common molecular imaging agent, fluoro-deoxy-glucose is metabolized at a cellular level. This will be followed by a talk on an improved approach to whole-body PET imaging by Simon Cherry (UC Davis). Simon’s work on a new whole-body PET imaging system promises to have dramatic improvement in our ability to detect and characterize cancer using PET. Finally, Jim Bankson (MD Anderson) will discuss extremely sophisticated approaches to quantifying hyperpolarized-13-C pyruvate metabolism using MR imaging. This technology promises to compliment the exquisite sensitivity of PET with an ability to measure not just uptake, but tumor metabolism. Learning Objectives: Understand the metabolism of FDG at a cellular level. Appreciate the engineering related to a novel new high-sensitivity whole-body PET imaging system. Understand the process of hyperpolarization, how pyruvate relates to metabolism and how advanced modeling can be used to better quantify this data. G. Pratx, Funding: 5R01CA186275, 1R21CA193001, and Damon Runyon Cancer Foundation. S. Cherry, National Institutes of Health; University of California, Davis; Siemens Medical SolutionsJ. Bankson, GE Healthcare; NCI P30-CA016672; CPRIT PR140021-P5.

60 APPLIED LIFE SCIENCES↗

Integrated imaging sensor systems with CMOS active pixel sensor technology

This paper discusses common approaches to CMOS APS technology, as well as specific results on the five-wire programmable digital camera-on-a-chip developed at JPL. The paper also reports recent research in the design, operation, and performance of APS imagers for several imager applications.

double sampling↗

A Scintillation-Fiber Based Cosmic-ray Muon Tomography System for Imaging Dry Storage Cask

Because of the growth of the nuclear power industry in the United States and the policy decision to ban reprocessing of commercial spent nuclear fuel, the spent fuel inventory at commercial reactor sites has been increasing. Spent nuclear fuel presents extra complexity of security and proliferation issues. These fuel assemblies are practically inaccessible for inspection purposes, as reopening a DSC would require special facilities and would be tremendously expensive. Cosmic-ray muon Tomography has been studied in the past for various applications and was demonstrated to be a good non-destructive assay technique for high-Z materials, such as spent nuclear fuel assemblies in dry storage casks (DSC). Compared to conventional imaging techniques, muon imaging has some advantages due to its negligible health risk and high penetrating power. In this paper, we report our simulation study on imaging a DSC using muon Tomography technique. The Point of Closest Approach (POCA) and the Maximum-Likelihood Expectation- Maximization (ML-EM) algorithms are implemented and evaluated. A scaled-down prototype muon tomography system is proposed and studied. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Information efficiency of line-scan imaging mechanisms

Information theory is used to formulate a single figure of merit for assessing the performance of line-scan imaging systems as a function of their spatial response (PSF or MTF), sensitivity, and sampling and quantization intervals and of the statistical properties of a random radiance field. Information density and efficiency (i.e., the ratio of information density to data density) tend to be optimum when the MTF and sampling passband of the imaging system are matched to the Wiener spectrum of the radiance field. Computational results for the statistical properties of natural radiance fields and the responses of common line-scan imaging mechanisms indicate that information density and efficiency are not strongly sensitive to variations in typical statistical properties of the radiance field and that the best practically realizable performance is approached when the sampling intervals are approximately 0.5-0.7 times the equivalent diameter of the PSF.

Huck, F. O.↗

Europium-doped aluminum oxide phosphors as indicators for frontal polymerization dynamics

In this study, we present an inexpensive and practical method that allows the monitoring and visualization of front polymerization, propagation, and dynamics. Commercially available europium-doped aluminum oxide powders were combined with video imaging to visualize free-radical propagating polymer fronts. In order to demonstrate the applicability of this method, frontal copolymerization reactions of propoxylated glycerin triacrylate (EB53), pentaerythritol triacrylate (PETA), and pentaerythritol tetra-acrylate (PETEA) with 1,1-Bis(tert-butylperoxy)-3,3,5-trimethylcyclohexane (Luperox 231®) as an initiator were studied and compared to the results obtained by IR imaging. Systems exhibiting higher filler loading, higher EB53 content, and less acrylated monomers showed a marked decrease in front velocity, while those with more acrylated monomers and higher crosslinking density showed a marked increase in front velocity. Finally, in order to show the potential of the imaging technique, we studied fronts propagating in planar and spherical geometries.

36 MATERIALS SCIENCE↗

A survey of SAR image-formation processing for earth resources applications

Currently there is considerable interest in active microwave sensors for earth resources applications, such as the SEASAT-A radar. However, to obtain spatial resolutions comparable to optical sensors at radar frequencies, sophisticated image formation processing techniques must be applied to the raw data. Processing requirements for non-coherent optical and coherent radar imaging systems are compared. The image formation processing requirements for synthetic aperture radar (SAR) systems are discussed. Both optical and digital techniques are addressed, and examples of hardware and imagery for each processing technique are presented.

Bayma, R. W.↗

Event-Driven 3D Sensing Architecture

Some events happen too quickly to capture twice. Whether tracking satellites, monitoring aircraft, observing autonomous systems, or recording high speed industrial processes, imaging systems often have only one opportunity to collect the right information. If a camera is focused on the wrong distance, uses the wrong exposure, or cannot keep pace with rapid motion, important details may be lost forever. Los Alamos National Laboratory has developed an event-driven imaging architecture that preserves more information during data collection than a conventional camera. Instead of committing to a single image, the system captures data that can later be used to digitally adjust focus and exposure while reconstructing the scene in three dimensions. The result is a more flexible approach for imaging dynamic environments where conventional cameras can struggle.

42 ENGINEERING↗

A Comprehensive Analysis of the Physical Properties of Advanced GaAs/AlGaAs Junctions

Extensive studies have been performed on MQW junctions and structures because of their potential applications as avalanche photodetectors in optical communications and imaging systems. The role of the avalanche photodiode is to provide for the conversion of an optical signal into charge. Knowledge of junction physics, and the various carrier generation/recombination mechanisms, is crucial for effectively optimizing the conversion process and increasing the structure's quantum efficiency. In addition, the recent interest in the use of APDs in imaging systems has necessitated the development of semiconductor junctions with low dark currents and high gains for low light applications. Because of the high frame rate and high pixel density requirements in new imaging applications, it is necessary to provide some front-end gain in the imager to allow operation under reasonable light conditions. Understanding the electron/hole impact ionization process, as well as diffusion and surface leakage effects, is needed to help maintain low dark currents and high gains for such applications. In addition, the APD must be capable of operating with low power, and low noise. Knowledge of the effects of various doping configurations and electric field profiles, as well as the excess noise resulting from the avalanche process, are needed to help maintain low operating bias and minimize the noise output.

Menkara, Hicham M.↗

Measurement of the Landsat Thematic Mapper modulation transfer function using an array of point sources

This paper presents a method for measuring the Thematic Mapper (TM) imaging system point spread function (PSF) using TM imagery or a specially constructed target consisting of a two-dimensional array of approximate point sources of known dimensions and radiometric qualities. The target allows 16 separate point sources to be imaged simultaneously by the TM. The point sources were carefully placed on the ground so that their relative positions were known. Owing to sample-scene phasing, each imaged point source exhibits a different amount of blur in the digital image. The target pixels may then be recombined according to their known relative positions to form a single, sampled, nonaliased imaging system PSF. The modulation transfer function is then obtained as the modulus of the discrete Fourier transform of the PSF.

Rauchmiller, Robert F., Jr.↗

Proton pinhole imaging on the National Ignition Facility

Pinhole imaging of large (mm scale) carbon-deuterium (CD) plasmas by proton self-emission has been used for the first time to study the microphysics of shock formation, which is of astrophysical relevance. The 3 MeV deuterium-deuterium (DD) fusion proton self-emission from these plasmas is imaged using a novel pinhole imaging system, with up to five different 1 mm diameter pinholes positioned 25 cm from target-chamber center. CR39 is used as the detector medium, positioned at 100 cm distance from the pinhole for a magnification of 4 ×. A Wiener deconvolution algorithm is numerically demonstrated and used to interpret the images. When the spatial morphology is known, this algorithm accurately reproduces the size of features larger than about half the pinhole diameter. For these astrophysical plasma experiments on the National Ignition Facility, this provides a strong constraint on simulation modeling of the experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coronagraphic Notch Filter for Raman Spectroscopy

A modified coronagraph has been proposed as a prototype of improved notch filters in Raman spectrometers. Coronagraphic notch filters could offer alternatives to both (1) the large and expensive double or triple monochromators in older Raman spectrometers and (2) holographic notch filters, which are less expensive but are subject to environmental degradation as well as to limitations of geometry and spectral range. Measurement of a Raman spectrum is an exercise in measuring and resolving faint spectral lines close to a bright peak: In Raman spectroscopy, a monochromatic beam of light (the pump beam) excites a sample of material that one seeks to analyze. The pump beam generates a small flux of scattered light at wavelengths slightly greater than that of the pump beam. The shift in wavelength of the scattered light from the pump wavelength is known in the art as the Stokes shift. Typically, the flux of scattered light is of the order of 10 7 that of the pump beam and the Stokes shift lies in the wave-number range of 100 to 3,000 cm 1. A notch filter can be used to suppress the pump-beam spectral peak while passing the nearby faint Raman spectral lines. The basic principles of design and operation of a coronagraph offer an opportunity for engineering the spectral transmittance of the optics in a Raman spectrometer. A classical coronagraph may be understood as two imaging systems placed end to end, such that the first system forms an intermediate real image of a nominally infinitely distant object and the second system forms a final real image of the intermediate real image. If the light incident on the first telescope is collimated, then the intermediate image is a point-spread function (PSF). If an appropriately tailored occulting spot (e.g., a Gaussian-apodized spot with maximum absorption on axis) is placed on the intermediate image plane, then the instrument inhibits transmission of light from an on-axis source. However, the PSFs of off-axis light sources are formed off axis - that is, away from the occulting spot - so that they become refocused onto the final image plane.

Cohen, David↗

Light microscopic image analysis system to quantify immunoreactive terminal area apposed to nerve cells

The present report describes a desktop computer-based method for the quantitative assessment of the area occupied by immunoreactive terminals in close apposition to nerve cells in relation to the perimeter of the cell soma. This method is based on Fast Fourier Transform (FFT) routines incorporated in NIH-Image public domain software. Pyramidal cells of layer V of the somatosensory cortex outlined by GABA immunolabeled terminals were chosen for our analysis. A Leitz Diaplan light microscope was employed for the visualization of the sections. A Sierra Scientific Model 4030 CCD camera was used to capture the images into a Macintosh Centris 650 computer. After preprocessing, filtering was performed on the power spectrum in the frequency domain produced by the FFT operation. An inverse FFT with filter procedure was employed to restore the images to the spatial domain. Pasting of the original image to the transformed one using a Boolean logic operation called 'AND'ing produced an image with the terminals enhanced. This procedure allowed the creation of a binary image using a well-defined threshold of 128. Thus, the terminal area appears in black against a white background. This methodology provides an objective means of measurement of area by counting the total number of pixels occupied by immunoreactive terminals in light microscopic sections in which the difficulties of labeling intensity, size, shape and numerical density of terminals are avoided.

Non-NASA Center↗

Realization of quasi-spherical implosion using pre-shaped prolate wire arrays with a compression foam target inside

Quasi-spherical (QS) implosion of wire arrays and its impact on the foam target have been studied on the 100 ns 1.5 MA Qiangguang-I facility, which suggests that a high quality impact between the QS implosion and foam target can be achieved by adjusting load's initial shape carefully to match the external magnetic pressure. Implosions of loads with H/d ∼ 1.2 were studied with a self-emission x-ray pinhole image system and a dark field schlieren system. The radially developed spike-like instabilities indicate the spherical convergence of plasma. The observed radiation on the foam target surface suggests satisfying implosion symmetry and wire-foam impact simultaneity. An average implosion speed of 10.5 × 10{sup 6 }cm/s was obtained with an optical streak image system. The derived peak kinetic energy density ∼2.1 kJ/cm is remarkably higher than cylindrical cases, which agree with the expectations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preparations for Tomographic Background-Oriented Schlieren at the 31-Inch Mach 10 Wind Tunnel

This paper details effort by researchers at NASA Langley Research Center to prepare for an upcoming high-speed tomographic background-oriented schlieren test entry in the 31-Inch Mach 10 wind tunnel. In order to troubleshoot potential problems that will arise when setting up the experiment in the actual test facility, a full-scale mock-up of the 31-Inch Mach 10 wind tunnel test section was constructed in the laboratory to provide equivalent characteristic optical access and mounting options. A 3D-printed model that replicates the scale of the forebody of a supersonic retropropulsion (SRP) model that will be used in the final test entry has been fabricated with a central nozzle that can be connected to a high-pressure gas supply to approximate the nozzle flow that will occur. Six high-speed imaging systems consisting of a high-speed camera with a fiber illuminator module have been assembled and mounted on the test section mock-up to provide six unique perspective views of the nozzle flow from the model. Tests with one of the imaging systems using a pulsed laser light source showed that sufficient signal intensity and illumination uniformity was achieved, as demonstrated by the 2D BOS data obtained with the system. Additional work to show that retroreflective material would survive inside of the test section of the 31-Inch Mach 10 tunnel was also performed. Finally, a remotely-controlled tomographic BOS calibration system is discussed.

Brett F Bathel↗

Simultaneous Luminescence Pressure and Temperature Measurement System for Hypersonic Wind Tunnels

Surface pressures and temperatures are determined from visible emission brightness and green-to-red color ratioing of induced luminescence from a ceramic surface with an organic dye coating. A ceramic-dye matrix of porous silica ceramic with an adsorbed dye is developed for high-temperature pressure sensitivity and stability (up to 150 C). Induced luminescence may be excited using a broad range of incident radiation from visible blue light (488-nm wavelength) to the near ultraviolet (365 nm). Ceramic research models and test samples are fabricated using net-form slip-casting and sintering techniques. Methods of preparation and effects of adsorption film thickness on measurement sensitivity are discussed. With the present 8-bit imaging system a 10% pressure measurement uncertainty from 50 to 760 torr is estimated, with an improvement to 5% from 3 to 1500 torr with a 12-bit imaging system.

Buck, Gregory M.↗

Information density and efficiency of two-dimensional /2-D/ sampled imagery

Information density and efficiency (i.e., the ratio of information density to data density) are used as criteria for assessing the quality of 2-D sampled and quantized imagery as a function of the statistical properties of random radiance fields, the spatial response (PSF or MTF) and sensitivity of imaging systems, and the sampling and quantization intervals. Computational results are intuitively satisfying: they are consistent with experimental and theoretical results obtained by earlier investigators concerned with the performance of TV cameras, and they provide useful guidelines for optimizing the design of line-scan and sensor-array imaging systems, especially if these systems use a digital communication link for transmitting data.

Huck, F. O.↗

Spot size measurement of a deuterium–tritium dense plasma focus using neutron radiography

Neutron radiography is a technique uniquely suited to applications in nuclear diagnostics, non-destructive testing, and subcritical experiments. The spatial resolution of neutron radiographs is degraded by optical blur in the imaging system and the neutron source size, where the ideal source is point-like to optimize the point-spread function. A potential neutron source for radiography is the dense plasma focus (DPF), a coaxial Z-pinch that produces thermonuclear and beam-target neutrons. To assess if the source size is suitable for radiography, a neutron imaging system was used to measure the source size of the 4 MA Sodium DPF at the Nevada National Security Site operating with deuterium–tritium gas-fill. The source size was measured using the edge-spread function of tungsten objects, each having a rolled (convex) edge. The spot size was found to be 7–12 mm full-width at half-max (FWHM) assuming a Gaussian source, though comparison is presented for Lorentzian and Bennett distributions. The average FWHM was found to be 8.6 ± 1.2 mm vertically and 10.8 ± 1.2 mm horizontally with respect to the image plane, averaging over varied edges and alignments. The results were sensitive to source alignment and edge metrology, which introduced notable uncertainties. These results are consistent with separate experimental measurements as well as magnetohydrodynamics simulations of this DPF, which suggest that neutron production can originate from pinches ∼5–7 mm off-axis. These results suggest that the DPF should be used for radiography at low magnification (M < 1) where spot size does not dominate spatial blur.

47 OTHER INSTRUMENTATION↗

Photonic Doppler velocimetry probe used to measure grain boundaries of dynamic shocked materials

Material scientists have developed computational modeling to predict the dynamic response of materials undergoing stress, but there is still a need to make precision measurements of surfaces undergoing shock compression. Miniature photonic Doppler velocimetry (PDV) probes have been developed to measure the velocity distribution from a moving surface traveling tens of kilometers per second. These probes use hundreds of optical fibers imaged by optical relays onto different regions of this moving surface. While previous work examined large surface areas, we have now developed a PDV microscope that can interrogate 37 different spots within a field of view of <1 mm, with a standoff distance of 17 mm, to analyze the motion differences across grain boundaries of the material undergoing dynamic stress. Each PDV fiber interrogates a 10 μm spot size on the moving surface. A separate imaging system using a coherent bundle records the location of the PDV spots relative to the grain boundaries prior to the dynamic event. Designing the mounting structures for the lenses, fibers, and coherent bundle was a challenge. To minimize back reflections, the fibers are index matched onto the first relay lens, which is made of fused silica. The PDV fibers are aligned normal to the moving surface. The imaging probe views the surface at an 18° angle. The coherent bundle is tilted 11° to its optical relay. All components are assembled into a single probe head assembly. The coherent bundle is removed from the probe head to be used for the next dynamic event. Alignment issues will also be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗