Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “home performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Evaluation of the Repeatability of the Delta Q Duct Leakage Testing TechniqueIncluding Investigation of Robust Analysis Techniques and Estimates of Weather Induced Uncertainty

The DeltaQ test is a method of estimating the air leakage from forced air duct systems. Developed primarily for residential and small commercial applications it uses the changes in blower door test results due to forced air system operation. Previous studies established the principles behind DeltaQ testing, but raised issues of precision of the test, particularly for leaky homes on windy days. Details of the measurement technique are available in an ASTM Standard (ASTM E1554-2007). In order to ease adoption of the test method, this study answers questions regarding the uncertainty due to changing weather during the test (particularly changes in wind speed) and the applicability to low leakage systems. The first question arises because the building envelope air flows and pressures used in the DeltaQ test are influenced by weather induced pressures. Variability in wind induced pressures rather than temperature difference induced pressures dominates this effect because the wind pressures change rapidly over the time period of a test. The second question needs to answered so that DeltaQ testing can be used in programs requiring or giving credit for tight ducts (e.g., California's Building Energy Code (CEC 2005)). DeltaQ modeling biases have been previously investigated in laboratory studies where there was no weather induced changes in envelope flows and pressures. Laboratory work by Andrews (2002) and Walker et al. (2004) found biases of about 0.5% of forced air system blower flow and individual test uncertainty of about 2% of forced air system blower flow. The laboratory tests were repeated by Walker and Dickerhoff (2006 and 2008) using a new ramping technique that continuously varied envelope pressures and air flows rather than taking data at pre-selected pressure stations (as used in ASTM E1554-2003 and other previous studies). The biases and individual test uncertainties for ramping were found to be very close (less than 0.5% of air handler flow) to those found in for the pressure station approach. Walker and Dickerhoff also included estimates of DeltaQ test repeatability based on the results of field tests where two houses were tested multiple times. The two houses were quite leaky (20-25 Air Changes per Hour at 50Pa (0.2 in. water) (ACH50)) and were located in the San Francisco Bay area. One house was tested on a calm day and the other on a very windy day. Results were also presented for two additional houses that were tested by other researchers in Minneapolis, MN and Madison, WI, that had very tight envelopes (1.8 and 2.5 ACH50). These tight houses had internal duct systems and were tested without operating the central blower--sometimes referred to as control tests. The standard deviations between the multiple tests for all four houses were found to be about 1% of the envelope air flow at 50 Pa (0.2 in. water) (Q50) that led to the suggestion of this as a rule of thumb for estimating DeltaQ uncertainty. Because DeltaQ is based on measuring envelope air flows it makes sense for uncertainty to scale with envelope leakage. However, these tests were on a limited data set and one of the objectives of the current study is to increase the number of tested houses. This study focuses on answering two questions: (1) What is the uncertainty associated with changes in weather (primarily wind) conditions during DeltaQ testing? (2) How can these uncertainties be reduced? The first question is addressing issues of repeatability. To study this five houses were tested as many times as possible over a day. Weather data was recorded on-site--including the local windspeed. The result from these five houses were combined with the two Bay Area homes from the previous studies. The variability of the tests (represented by the standard deviation) is the repeatability of the test method for that house under the prevailing weather conditions. Because the testing was performed over a day a wide range of wind speeds was achieved following typical diurnal variations of low wind in the early morning and greatest winds in the late afternoon/early evening. Typically about ten tests were performed in each house. To answer the second question, different data analysis techniques were investigated that looked at averaging techniques, elimination of outliers, limiting leak pressures, etc. in order to minimize the influence of changing wind conditions during the test. The objective was to find a reasonable compromise between test precision and robustness--because many of the changes to the analysis to make the test more robust limit its ability to examine wide ranges of pressures and leakage flows. A secondary goal of this study is to show that DeltaQ uncertainties are acceptable for testing low leakage systems. Therefore houses with low duct leakage were deliberately chosen to be tested.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Studying Turbulence Using Numerical Simulation Databases: Proceedings of the Summer Program - No. 7

The Seventh Summer Program of the Center for Turbulence Research took place in the four-week period, July 5 to July 31, 1998. This was the largest CTR Summer Program to date, involving thirty-six participants from the U. S. and nine other countries. Thirty-one Stanford and NASA-Ames staff members facilitated and contributed to most of the Summer projects. A new feature, and perhaps a preview of the future programs, was that many of the projects were executed on non-NASA computers. These included supercomputers located in Europe as well as those operated by the Departments of Defense and Energy in the United States. In addition, several simulation programs developed by the visiting participants at their home institutions were used. Another new feature was the prevalence of lap-top personal computers which were used by several participants to carry out some of the work that in the past were performed on desk-top workstations. We expect these trends to continue as computing power is enhanced and as more researchers (many of whom CTR alumni) use numerical simulations to study turbulent flows. CTR's main role continues to be in providing a forum for the study of turbulence for engineering analysis and in facilitating intellectual exchange among the leading researchers in the field. Once again the combustion group was the largest. Turbulent combustion has enjoyed remarkable progress in using simulations to address increasingly complex and practically more relevant questions. The combustion group's studies included such challenging topics as fuel evaporation, soot chemistry, and thermonuclear reactions. The latter study was one of three projects related to the Department of Energy's ASCI Program (www.llnl.gov/asci); the other two (rocket propulsion and fire safety) were carried out in the turbulence modeling group. The flow control and acoustics group demonstrated a successful application of the so-called evolution algorithms which actually led to a previously unknown forcing strategy for jets yielding increased spreading rate. A very efficient algorithm for flow in complex geometries with moving boundaries based on the immersed boundary forcing technique was tested with very encouraging results. Also a new strategy for the destruction of aircraft trailing vortices was introduced and tested. The Reynolds Averaged Modeling (RANS) group demonstrated that the elliptic relaxation concept for RANS calculations is also applicable to transonic flows with shocks; however, prediction of laminar/turbulent transition remains an important pacing item. A large fraction of the LES effort was devoted to the development and testing of a new algorithmic procedure (as opposed to phenomenological model) for subgrid scale modeling based on regularized de-filtering of the flow variables. This appears to be a very promising approach, and a significant effort is currently underway to assess its robustness in high Reynolds number flows and in conjunction with numerical methods for complex flows. As part of the Summer Program two review tutorials were given on Turbulent structures in hydrocarbon pool fires (Sheldon Tieszen), and Turbulent combustion modeling: from RANS to LES via DNS (Luc Vervisch); and two seminars entitled Assessment of turbulence models for engineering applications (Paul Durbin) and Subgrid-scale modeling for non-premixed, turbulent reacting flows (James Riley) were presented. A number of colleagues from universities, government agencies, and industry attended the final presentations of the participants on July 31 and participated in the discussions. There are twenty-six papers in this volume grouped in five areas. Each group is preceded with an overview by its coordinator.

Source record↗

Data Management and Science at DOE BES User Facilities – Past, Present, and Future

The primary mission of user facilities operated by Basic Energy Sciences under the Department of Energy is to produce data for users in support of open science and basic research. We trace back almost 30 years of history across selected user facilities illustrating the evolution of facility data management practices and how these practices have related to performing scientific research. The facilities cover multiple techniques such as X-ray and neutron scattering, imaging and tomography sciences. Over time, detector and data acquisition technologies have dramatically increased the ability to produce prolific volumes of data challenging the traditional paradigm of users taking data home upon completion of their experiments to process and publish their results. During this time, computing capacity has also increased dramatically, though the size of the data has grown significantly faster than the capacity of one's laptop to manage and process this new facility produced data. Trends indicate that this will continue to be the case for yet some time. Thus users face a quandary for how to manage today's data complexity and size as these may exceed the computing resources users have available to themselves. This same quandary can also stifle collaboration and sharing. Realizing this, some facilities are already providing web portal access to data and computing thereby providing users access to resources they need. Portal based computing is now driving researchers to think about how to use the data collected at multiple facilities in an integrated way to perform their research, and also how to collaborate and share data. In the future, inter-facility data management systems will enable next tier cross-instrument-cross facility scientific research fuelled by smart applications residing upon user computer resources. We can learn from the medical imaging community that has been working since the early 1990's to integrate data from across multiple modalities to achieve better diagnoses - similarly, data fusion across BES facilities will lead to new scientific discoveries.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Homocysteine and Cognitive Performance in Elders with Self-Neglect

Elevated plasma homocysteine has been associated with altered cognitive performance in older adults. Elders referred to Adult Protective Services (APS) for self-neglect have been reported to have elevated plasma homocysteine levels and to suffer from cognitive impairment. This study assesses the association, if any, between plasma homocysteine and cognitive performance among elders with self-neglect. Methods: Sixty-five community-living adults, 65 years of age and older, reported to Adult Protective Services for self-neglect and 55 matched controls (matched for age, ethnicity, gender and socio-economic status) consented and participated in this study. The research team conducted in-home comprehensive geriatric assessments which included the mini-mental state exam (MMSE), the 15-item geriatric depression scale (GDS), the Wolf-Klein Clock Drawing Tests (CDT) and a comprehensive nutritional biochemistry panel, which included plasma homocysteine. Student s t tests and Pearson correlations were conducted to assess for bivariate associations. Results: Elders with self-neglect had significantly higher plasma homocysteine levels (M=12.68umol/L, sd=4.4) compared to the controls (M=10.40umol/L, sd=3.61;t=3.21, df=127, p=.002). There were no statistically significant associations between cognitive performance and plasma homocysteine in the self-neglect group, however there was a significant correlation between plasma homocysteine and the CDT among the controls (r=-.296, p=.022). Conclusion: Mean plasma homocysteine levels were significantly higher in elders with self-neglect, however, they do not appear to be related to cognitive performance, indicating that cognitive impairment in elder self-neglect involve mechanisms other than hyperhomocysteinemia. These findings warrant further investigation

Burnett, J.↗

Data Management and Its Role in Delivering Science at DOE BES User Facilities – Past, Present, and Future

Abstract. The primary mission of user facilities operated by Basic Energy Sciences under the Department of Energy is to produce data for users in support of open science and basic research [1]. We trace back almost 30 years of history across selected user facilities illustrating the evolution of facility data management practices and how these practices have related to performing scientific research. The facilities cover multiple techniques such as X-ray and neutron scattering, imaging and tomography sciences. Over time, detector and data acquisition technologies have dramatically increased the ability to produce prolific volumes of data challenging the traditional paradigm of users taking data home upon completion of their experiments to process and publish their results. During this time, computing capacity has also increased dramatically, though the size of the data has grown significantly faster than the capacity of one’s laptop to manage and process this new facility produced data. Trends indicate that this will continue to be the case for yet some time. Thus users face a quandary for how to manage today’s data complexity and size as these may exceed the computing resources users have available to themselves. This same quandary can also stifle collaboration and sharing. Realizing this, some facilities are already providing web portal access to data and computing thereby providing users access to resources they need [2]. Portal based computing is now driving researchers to think about how to use the data collected at multiple facilities in an integrated way to perform their research, and also how to collaborate and share data. In the future, inter-facility data management systems will enable next tier cross-instrument-cross facility scientific research fuelled by smart applications residing upon user computer resources. We can learn from the medical imaging community that has been working since the early 1990’s to integrate data from across multiple modalities to achieve better diagnoses [3] – similarly, data fusion across BES facilities will lead to new scientific discoveries.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Conway Street Apartments: A Multifamily Deep Energy Retrofit

While single-family, detached homes account for 63% of households (EIA 2009); multi-family homes account for a very large portion of that remaining housing stock, and this fraction is growing. Through recent research efforts, CARB has been evaluating strategies and technologies that can make dramatic improvements in energy performance in multi-family buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Conway Street Apartments: A Multifamily Deep Energy Retrofit

While single-family, detached homes account for 63% of households (EIA 2009); multi-family homes account for a very large portion of that remaining housing stock, and this fraction is growing. Through recent research efforts, CARB has been evaluating strategies and technologies that can make dramatic improvements in energy performance in multi-family buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Telecommuting (Work-At-Home) at NASA Lewis Research Center

This report presents a study in evaluating the viability of providing a work-at-home (telecommuting) program for Lewis Research Center's corporate employees using Integrated Services Digital Network (ISDN). Case studies have been presented for a range of applications from casual data access to interactive access. The network performance of telemedia applications were studied against future requirements for such level of remote connectivity. Many of the popular ISDN devices were characterized for network and service functionality. A set of recommendations to develop a telecommuting policy have been proposed.

Srinidhi, Saragur M.↗

A Survey of Staphylococcus sp and its Methicillin Resistance aboard the International Space Station

Background: Within the past few years, methicillin-resistant Staphylococcus aureus has emerged in environments with susceptible hosts in close proximity, such as hospitals and nursing homes. As the International Space Station (ISS) represents a semi-closed environment with a high level of crewmember interaction, an evaluation of isolates of clinical and environmental Staphylococcus aureus and coagulase negative Staphylococcus was performed to determine if this trend was also present in astronauts occupying ISS or on surfaces of the space station itself. Methods: Identification of isolates was completed using VITEK (GPI cards, BioMerieux), 16S ribosomal DNA analysis (MicroSeq 500, ABI), and Rep-PCR DNA fingerprinting (Divemilab, Bacterial Barcodes). Susceptibility tests were performed using VITEK (GPS-105 cards, BioMerieux) and resistance characteristics were evaluated by testing for the presence of the mecA gene (PBP2' MRSA test kit, Oxoid). Results: Rep-PCR analysis indicated the transfer of S. aureus between crewmembers and between crewmembers and ISS surfaces. While a variety of S. aureus were identified from both the crewmembers and environment, evaluations of the microbial population indicated minimal methicillin resistance. Results of this study indicated that within the semi-closed ISS environment, transfer of bacteria between crewmembers and their environment has been occurring, although there was no indication of a high concentration of methicillin resistant Staphylococcus species. Conclusions: While this study suggests that the spread of methicillin resistant S. aureus is not currently a concern aboard ISS, the increasing incidence of Earth-based antibiotic resistance indicates a need for continued clinical and environmental monitoring.

Bassinger, V. J.↗

Building America Case Study: Conway Street Apartments, Greenfield, Massachusetts (Fact Sheet)

While single-family, detached homes account for 63% of households (EIA 2009); multi-family homes account for a very large portion of that remaining housing stock, and this fraction is growing. Through recent research efforts, CARB has been evaluating strategies and technologies that can make dramatic improvements in energy performance in multi-family buildings

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Byggmeister Test Home: Analysis and Initial Results of Cold Climate Wood-Framed Home Retrofit

The Building Science Corporation seeks to further the energy efficiency market for retrofit projects in the New England area by supporting projects that are based on solid building science fundamentals and verified implementation. The Building Science Corporation has been working with Byggmeister, a partner on its Building America Program team, on retrofit projects. Byggmeister is a Boston-area design-build firm that specializes in energy efficient retrofits and new construction. The DEAP (Duclos, Eldrenkamp and Panish) Energy Group, which is associated with Byggmeister, conducts energy analysis for projects during design and performs monitoring after completion. With the high exposure of energy efficiency and retrofit terminology currently being used in the general media, it is important to have evidence that measures being proposed will in fact benefit the homeowner through a combination of energy savings, improved durability, and occupant comfort. Concrete data from specific projects can close the gap between “hype” and reality. This technical report describes a deep energy retrofit project for a two-family wood framed home located in Belmont, Massachusetts. Built in the 1920s, this home is referred to in this report as the “Belmont Two-Family.” The report examines the retrofit measures for the enclosure and mechanical systems and the decision making that took place during project planning. Because the retrofit project is complete, projected and actual energy use data are compared for the 5 months immediately following the retrofit. Occupant reactions and experiences are also described. The retrofit measures implemented for the Belmont Two-Family resulted in a home with airtightness of 0.93 air changes per hour at 50 pascal test pressure, a Home Energy Rating System index of 44 (excluding photovoltaics), and initial energy use significantly less than the energy models projected. The home is on track to meet the Thousand Home Challenge. In these ways, the project meets or exceeds the energy goals established for the retrofit. Energy modeling tools were found to be useful during the planning stage for investigating the relative cost effectiveness of retrofit measures. They were less effective, however, in projecting actual energy use. Discrepancies between the results of different tools need to be better understood, and interactions among retrofit measures are not effectively handled by the energy modeling tools at this time. During the first few months after the retrofit, the homeowner had questions about the effective operation of the mechanical equipment. With the increased airtightness and R-values, the equipment needs to be operated differently to realize the potential energy savings. This information needs to be better understood and disseminated by everyone involved with retrofit projects. This technical report contributes to several basic areas of research. These include the combination of measures that is feasible, affordable, and acceptable to homeowners as well as expectations versus results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Surveys of Microwave Ovens in U.S. Homes

The U.S. Department of Energy (DOE) is conducting test procedure and energy conservation standard rulemakings for microwave ovens. These units generally offer a “convection,” “bake,” or “combo” cooking mode on the user interface. DOE divides products under analysis into classes by the type of energy used, capacity, or other performance-related features that affect consumer utility and efficiency. Installation types are grouped as (1) countertop and (2) built-in and over-the-range. The following sub-sections summarize the existing data as well as the specific data LBNL obtained with surveys.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impairment of Human Ocular Tracking with Low-Dose Alcohol

Previous studies have documented adverse effects of alcohol on oculomotor performance. For example, moderate-dose alcohol (yielding a Blood Alcohol Concentration or BAC of 0.04-0.1%) has been shown to decrease steady-state pursuit gain (Fransson et al., 2010, Clin Neurophysiol, 121(12): 2134; Moser et al., 1998, J Neurol, 245(8): 542; Roche & King, 2010, Psychopharmacology, 212(1): 33), to increase saccade latency (Moser et al., 1998, J Neurol, 245(8): 542; Roche & King, 2010, Psychopharmacology, 212(1): 33), to decrease peak saccadic velocity (Fransson et al., 2010, Clin Neurophysiol, 121(12): 2134; Roche & King, 2010, Psychopharmacology, 212(1): 33), and to increase the frequency of catch-up saccades (Moser et al., 1998, J Neurol, 245(8): 542). Here, we administered two doses of ethanol on different days, yielding moderate (0.06%) and low (0.02%) levels of initial BAC, to examine the effects on human ocular tracking over BACs ranging from 0.00 to 0.07%. Twelve subjects (8 females) participated in a 5-day study. Three days of at-home measurements of daily activity and sleep were monitored, followed by two laboratory days where, ~5 hours after awakening, we administered one of the two possible single doses of alcohol. Using a previously published paradigm (Liston & Stone, 2014, J Vis, 14(14): 12), we measured oculomotor performance multiple times throughout the day with three pre-dosing baseline runs and bi-hourly post-dosing test runs until the subject recorded a BAC of 0.00% for two hours. BAC was measured before each run using an Alco-Sensor IV breathalyzer (Intoximeters, Inc., St. Louis, MO). For each of the oculometric measures, for each subject, we computed the within-subject % deviation for each test run from their baseline averaged across their three pre-dosing runs. We then averaged the data across subjects in 0.01% BAC bins. Finally, we used linear regression to compute the slope and x-intercept (threshold) of the mean binned % deviation as a function of BAC. We found that pursuit initiation was impaired at very low BAC levels, with significant (p < 0.002) linear trends in latency (+1.3%/0.01%BAC) and initial acceleration (-4.6%/0.01%BAC) with extrapolated absolute thresholds at or below 0.01% BAC. We also found that steady-state tracking was impaired showing significant (p < 0.002) linear trends in gain (- 3.8%/0.01%BAC) and catch-up saccade amplitude (+9.1%/0.01%BAC), again with extrapolated absolute thresholds around 0.01% BAC. We also found a significant (p < 0.02) increase in pursuit direction noise (+9.8%/0.01%BAC) with an extrapolated absolute threshold below 0.01% BAC. Many aspects of ocular tracking are impaired in a dose-dependent manner beginning at a BAC level around 0.01%, with significant effects at levels lower than previously reported and up to 8-times lower than the legal limit for driving in most states.

human performance↗

Sustainability and affordability of building electrification: A state-by-state holistic approach for multifamily buildings

This paper explores the evolving narrative of building electrification, considering its potential to solve climate change. Previous research has predominantly focused on hybrid renewable energy portfolios and increasing home pricing premiums, overlooking the perspectives of renters burdened by housing costs. Moreover, existing studies have primarily examined the effects of electrification on single-family homes and case studies, neglecting multifamily buildings and their relationship with the grid. This comprehensive study leverages calibrated building energy models to address these gaps and evaluates sustainability through carbon dioxide emissions and affordability through economic performance. The findings demonstrate significant progress in electrification since 2017, with nearly all states showing decreased energy usage in the electrified models. Environmentally, twenty-two states perform better or comparably with the electrified models in the most recent study. Economically, challenges persist, but a sensitivity analysis demonstrates how results could improve soon. Furthermore, the study discusses the outlook of electrified multifamily buildings, considering ongoing decarbonization plans for the electric grid. In three case studies, electrification demonstrates improvements in over half of the states by 2026. Overall, the research highlights the importance of expanding analysis to include multifamily buildings and emphasizes the positive impact of electrification as a viable energy, environmental, and economic solution.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Frictional and Lithological Controls on Shallow Slow Slip at the Northern Hikurangi Margin

Slow slip events (SSEs) have been identified at subduction zones globally as an important link in the continuum between elastodynamic ruptures and stable creep. The northern Hikurangi margin is home to shallow SSEs which propagate to within 2 km of the seafloor and possibly to the trench, providing insights into the physical conditions conducive to SSE behavior. We report on a suite of friction experiments performed on protolith material entering the SSE source region at the Hikurangi margin, collected during the International Ocean Discovery Program Expedition 375. We performed velocity stepping and slide-hold-slide experiments over a range of fault slip rates, from plate rate (5 cm/yr or 1.6 × 10 –9 m/s) to ~1 mm/s (10 –3 m/s) and quantified the frictional velocity dependence and healing rates for a range of lithologies atdifferent stresses. The frictional velocity dependence (a-b) and critical slip distance DC increase with fault slip rate in our experiments. We observe atransition from velocity weakening to strengthening at slip rates of ~0.3 µm/s. This velocity dependence of DC could be due to a combination of dilatant strengthening and a widening of the active shear zone at higher slip rates. We document low healing rates in the clay-rich volcaniclastic conglomerates, which lie above the incoming plate basement at least locally, and relatively higher healing rates in the chalk lithology. Finally, our experimental constraints on healing rates in different input lithologies extrapolated to timescales of 1–10 years are consistent with the geodetically inferred low stress drops and healing rates characteristic of the Hikurangi SSEs.

58 GEOSCIENCES↗

An Implementation for Transforming a Home Energy Management System to a Multi-agent System

In the United States, 41% of produced energy is consumed by the building sector, i.e. residential and commercial buildings (Building Energy Data Book, Buildings Sector, US Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Office, 2012. n.d.). The anticipation is that Home Energy Management Systems (HEMS) will support energy efficiency gains through control of the devices in an optimal fashion. New opportunities are offering the ability to integrate grid type controls and the most suitable way to perform these controls is through a multi-agent system (MAS). In this paper, approaches on supporting a HEMS and MAS integration are discussed.

Zandi, Helia↗

Improving Gas Furnace Performance: A Field and Laboratory Study at End of Life

In 2010, natural gas provided 54% of total residential space heating energy the U.S. on a source basis, or 3.5 Quadrillion Btu. Natural gas burned in furnaces accounted for 92% of that total, and boilers and other equipment made up the remainder. A better understanding of installed furnace performance is a key to energy savings for this significant energy usage. In this project, the U.S. Department of Energy Building America team Partnership for Advanced Residential Retrofit examined the impact that common installation practices and age-induced equipment degradation may have on the installed performance of natural gas furnaces over the life of the product, as measured by steady-state efficiency and annual efficiency. The team identified 12 furnaces of various ages and efficiencies that were operating in residential homes in the Des Moines, Iowa, metropolitan area and worked with a local heating, ventilation, and air conditioning contractor to retrieve furnaces and test them at the Gas Technology Institute laboratory for steady-state efficiency and annual efficiency. Prior to removal, system airflow, static pressure, equipment temperature rise, and flue loss measurements were recorded for each furnace as installed in the house.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗