Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid impact analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Electromagnetic Transient Modeling of Large Data Centers for Grid-Level Studies

The magnitude and complexity of electricity usage patterns from large data centers are having significant impacts on the operation and dynamics of the power grid; grid operators and planners require a range of specialized data center models to properly evaluate these impacts and specify technical solutions as needed. Towards addressing this need, Pacific Northwest National Laboratory (PNNL) has developed a library of electromagnetic transient (EMT) models for grid-level studies of data centers called the data center model library (DML). This report describes how the DML was created and how it may properly be used. The models present in the DML are generic models; subject matter expertise and additional technical data are needed to modify these models before they can represent any real data center. However, they will significantly reduce the level of effort required to develop site-specific models and can serve as a common starting point to guide industry towards a more refined consensus. Most of the models within DML are dedicated to representing the power electronics interfaces commonly used in modern data centers, such as double-conversion uninterruptible power supplies and single-phase power factor correction converters. These models are intended for use in grid-level studies and are a simplified aggregation of many small components. That said, background material on the physical and electrical design of large data centers is provided as companion material so that users can be aware of many of the details which have been omitted or streamlined as a matter of practical necessity. Additionally, guidance on the application of EMT analysis for data center interconnection studies is provided, which aids users in identifying when the DML is necessary and what sort of additional model development may be necessary for conducting real-world studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Frequency Signature-Based Fault Detection for Future MV Distribution Grids

Increasing penetration levels of inverter based distributed energy resources (DERs) impact the legacy distribution system protection. Inverter based DERs provide approximately 1.2-2 pu fault current. In systems with high penetration of inverter based DERs, it is difficult for over-current based protection schemes to differentiate between normal loading conditions and a fault. Directional, distance, and adaptive forms of protection schemes are also affected by low fault currents. This paper analyzes fault generated traveling wave (TW) based high-frequency signatures in the distribution system. In order to simulate such signatures, frequency-dependent distributed parameter line modeling approach is used in this research work to represent distribution lines and underground cables. Modified IEEE 13-bus medium voltage test system is modeled in electromagnetic transient simulation tool and multiple transient scenarios are simulated in this test system. The results are analyzed to understand the high-frequency signatures that can be used to detect and locate faults under high penetration of DERs.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Renewable Electrolysis System Development (Final Report)

Renewable hydrogen is becoming globally recognized as a key component required for de-carbonization of our energy system, both as a medium for capture of excess renewable energy sources, vehicle refueling, and as an intermediate for multiple industrial processes. Hydrogen production, via low-temperature electrolysis, is a flexible grid-friendly, clean energy carrying intermediate that enables fast ramp and de-ramp rates as naturally varying solar, wind, and storage systems become a larger percentage of the electricity mix. Analysis shows that by 2050, employing renewable hydrogen at scale can decrease total U.S. CO 2 emissions by about half relative to business as usual, critical to achieving >80% greenhouse gas reduction targets. Energy storage systems help commercial customers reduce their electric bills by storing energy from the grid or from renewable electricity sources when energy is inexpensive, then using that stored energy when demand and prices are high. Proton exchange membrane (PEM) electrolysis is one of the few technologies that can produce hydrogen with zero carbon emissions at relevant scale (hundreds of MWs) in the near term. NREL's research has shown that electrolyzers are fast and flexible enough to participate in energy and ancillary service markets that can help stabilize the grid. In 2015, Proton OnSite (now NEL Hydrogen) introduced the M-series electrolyzer platform, the world's first megawatt PEM electrolyzer for the global energy storage market, offering a carbon-free source of hydrogen fuel or process gas. In addition, the ability to sell the hydrogen into a high value application like vehicle (e.g., light- and heavy-duty and material handling) fueling allows for a layering of revenue streams that creates better business cases for hydrogen energy storage systems (HES). The ability to provide multiple value streams from the fast-responding controllable electrolyzer will have a direct impact on the net cost of hydrogen.

08 HYDROGEN↗

Securing Grid-interactive Efficient Buildings (GEB) through Cyber Defense and Resilient System (CYDRES)

The DOE CYDRES project is driven by the urgent need to address critical research gaps in the domain of cyber-physical security of smart buildings, including Grid-interactive Efficient Buildings (GEBs). CYDRES, a real-time advanced building resilient platform, aims to enhance the cyber-attack-immune capabilities of buildings through multi-layered prevention, detection, and adaptation mechanisms. CYDRES consists of five key modules: a multi-layer network analyzer, an Automatic Fault Detection, Diagnosis, and Prognosis (AFDDP) framework, an intelligent mode selector, a cyber-resilient control framework, and a situation awareness platform. The Network Analyzer employs a data-driven framework that includes a protocol state learning tool and a CRF (Conditional Random Field) command validator. In Hardware-In-the-Loop (HIL) testbeds, it achieved 100% detection accuracy with a false alarm rate of 3%, validating its efficacy in identifying selected cyber-attacks. The AFDDP framework leverages pattern matching, PCA (Principal Component Analysis)-based strategies, and a DBN (Dynamic Bayesian Network)-based fault diagnosis approach to pinpoint the causes of physical system abnormalities using Building Automation System (BAS) data. In HIL experiments, the AFDDP module attained a detection accuracy of over 95% with a false alarm rate below 7%. Additionally, the fault detector utilized machine learning (Random Forest) and deep learning (Multi-Layer Perceptron) methods with acoustic sensor data to achieve a 100% fault detection accuracy in Heating, Ventilation, and Air-Conditioning (HVAC) equipment. The Mode Selector offered real-time impact analysis, allowing immediate actions to protect BASs in the face of emerging threats. The cyber-resilient control framework included an adaptive Model Predictive Control (MPC) and a measurement compensator, reducing temperature violations by up to 94% and improving the total demand flexibility by up to 70% in HIL experiments. Such HIL experiments covered a cyber-attack case and a physical fault case, showcasing CYDRES’ efficiency in maintaining operational continuity during threats. The situation awareness platform in Grafana enhanced real-time threat detection and response visualization, augmenting the operational awareness for building operators. CYDRES demonstrated high technical effectiveness in various test scenarios, particularly in HIL environments. The project's phased development approach ensured efficient use of resources, highlighting its practical feasibility and readiness for commercialization. By enhancing the security and resilience of building operations, CYDRES represents a significant advance in mitigating risks associated with cyber-physical systems, thereby enhancing public confidence in the safety of modern building infrastructure. Future directions for the project include expanding testing protocols, refining AFDDP methodologies, exploring more comprehensive resilient control strategies, and testing in real commercial buildings.

42 ENGINEERING↗

CFD and X-ray Analysis of Gaseous Direct Injection from an Outward Opening Injector

Using natural gas in an internal combustion engine (ICE) is emerging as a promising way to improve thermal efficiency and reduce exhaust emissions. In the development of such engine platforms, computational fluid dynamics (CFD) plays a fundamental role in the optimization of geometries and operating parameters. One of the most relevant issues in the simulation of direct injection (DI) gaseous processes is the accurate prediction of the gas jet evolution. The simulation of the injection process for a gaseous fuel does not require complex modeling, nevertheless properly describing high-pressure gas jets remains a challenging task. At the exit of the nozzle, the injected gas is under-expanded, the flow becomes supersonic and shocks occur due to compressibility effects. These phenomena lead to challenging computational requirements resulting from high grid resolution and low computational time-steps. In this paper, the simulation of gaseous injection from an outward opening injector was carried out with the commercial CFD software CONVERGE. Argon was injected into a quiescent chamber filled with Nitrogen. Two free-jet cases with injection pressure of 15 and 10 bar, and ambient pressure of 1 and 2 bar respectively, were tested. For the 15 bar injection pressure and 1 bar ambient pressure, a jet impinging on a barrier case was performed as well. The numerical results were validated against experimental mass measurements using X-ray radiography. The results, presented in terms of 2D maps and transverse sections of equivalent path length of argon, showed good agreement between modeling and experiments in terms of jet penetration, shape and gas mass distribution. These emphasized the significant impact of mesh size on the results for the simulation of this type of injector. Due to the small geometrical dimensions a fine mesh is required in order to deliver an accurate description of the mixture formation. Numerical results were discussed with a particular emphasis on the application to engine simulations, where a trade-off between accuracy and computational time is a necessity.

Bartolucci, Lorenzo↗

Lightning Strike Distance Distribution Beyond a Preexisting Lightning Area

The 45th Weather Squadron (45 WS) asked the Applied Meteorology Unit (AMU) to review the 30-year-old, lightning stand-off distances of 5 nautical miles (nmi) for applicability to today's operations. This was based on the realization that previous lightning strike distance studies did not match how 45 WS issues lightning warnings (Roeder, 2008). The previous lightning distance studies were from the point of origin of the lightning or the average starting location that would tend to be in the core of the thunderstorm. However, the 45 WS issues lightning warnings based on the edge of a preexisting lightning area. Before beginning the AMU project, it took several years to develop a method to calculate a distance distribution beyond a preexisting area (Roeder, 2015). The AMU pulled Lightning Detection and Ranging (LDAR) sensor data from 1/1/2013 to 12/31/2013. This dataset consisted of 37 million individual source data points from the LDAR sensors. Only sources within 50 km north, south, east or west of the LDAR grid center were included in the dataset. This limited the use of LDAR data to that with the greatest accuracy of source detection and increased data processing. Points were grouped into flashes based on spatial and temporal criteria. Based on the sensitivity analysis the AMU performed on the flash clustering algorithm, a time value of 0.3 seconds was found to model flashes adequately. Distance parameters were tested from 1,500 to 7,500 meters (m) in 500 m increments. Distance parameters of both 3,000 m and 4,000 m produced results in the plotting tool that were most representative of the physical behavior of lightning. Thus statistics were gathered for the most representative of these spatial and temporal criteria on the flash size and the polygon expansion distance in order to find the correct data distributions. The best fit curves for the LDAR polygon expansion frequency vs. distances for both the 3 kilometer (km) and 4 km distance threshold values were exponential decay functions and had R2 values of > 0.998, indicating good model fits. The equations of the best fit curves were then used to calculate a desired safety radius of 4 nmi for either 3 km or 4 km distance threshold criteria. The AMU analysis concludes the safe reduction of the 5 nmi lightning warning circles to 4 nmi should improve the operational impact by 36% if based on distance from the center of the property area being protected. If based on the edge of the property being protected, then the reduction is 4.5 nmi to 4 nmi and the operational impact is decreased by 21%. For the 6 nmi lightning warning circles, the recommended 4 nmi stand-off distance will result in a safe reduction of operational impact of 31% if based on the center of the area being protected, or 16% if based on the edge of the property.

Flash clustering algorithm↗

Revenue Opportunities through Ancillary Services for Nuclear Power Plants with Integrated Firebrick Resistance- Heated Energy Storage (FIRES)

Deregulation of electricity markets has brought about major changes in the ways investments in and operation of power plants are planned and optimized. Although many NPPs have seen reduced revenue in recent years as power purchase agreement end and wholesale market electricity prices have remained low, there are opportunities to expand the technical capabilities of NPPs, participate in additional market services and increase revenue. This transaction summarizes the opportunities provided by participation in ancillary services markets potentially made possible by integration of thermal energy storage capacity, specifically the Firebrick Resistance-heated Energy Storage System (FIRES), into future nuclear power plants with high-temperature reactors and Nuclear Air-Brayton combined cycle (NACC) power conversion. The restructuring, or deregulation, of electric power systems in most of Europe and North America has had a substantial impact on the economic performance of currently operating nuclear power plants (NPPs) and the prospects for new builds. Owners of NPPs in some markets have expressed concern that low wholesale electricity market prices and insufficient compensation for capacity, reliability, and other services are threatening the financial viability of their plants. However, both current and future NPPs have the potential to increase their competitiveness by increasing the flexibility of their electricity output. Flexible output has previously only been possible in water-cooled reactors through load-following operation, which requires core power maneuvers and operation of the steam turbine at reduced efficiency. Integration of thermal energy storage systems (TESS) provides an alternative, providing the plant the option to either output electricity or store heat for greater later electric output. The plant owner may thus increase sales of electricity during hours when it is most valuable. Even more, some TESS technologies have the potential to greatly increase the net ramp rate capability of the plant. The ability to rapidly change net power output to the grid may make it possible for NPPs to secure additional revenue by providing additional minute-by-minute balancing services to the grid. FIRES is only one technology out of many that might provide additional technical capabilities at NPPs, and this discussion has only highlighted the opportunities in a single market. Analysis of other options, include steam accumulator systems, nitrate salt TESS, phase change material TESS, and opportunities in other markets are subjects of ongoing work. Deregulation of electricity markets has brought about major changes in the ways investments in and operation of power plants are planned and optimized. Although many NPPs have seen reduced revenue in recent years as power purchase agreements end and wholesale market electricity prices have remained low, there are opportunities to expand the technical capabilities of NPPs, participate in additional market services, and increase revenue. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High-Frequency Signature-Based Fault Detection for Future MV Distribution Grids

Increasing penetration levels of inverter based distributed energy resources (DERs) impact the legacy distribution system protection. Inverter based DERs provide approximately 1.2-2 pu fault current. In systems with high penetration of inverter based DERs, it is difficult for over-current based protection schemes to differentiate between normal loading conditions and a fault. Directional, distance, and adaptive forms of protection schemes are also affected by low fault currents. This paper analyzes fault generated traveling wave (TW) based high-frequency signatures in the distribution system. In order to simulate such signatures, frequency-dependent distributed parameter line modeling approach is used in this research work to represent distribution lines and underground cables. Modified IEEE 13-bus medium voltage test system is modeled in electromagnetic transient simulation tool and multiple transient scenarios are simulated in this test system. The results are analyzed to understand the high-frequency signatures that can be used to detect and locate faults under high penetration of DERs.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Multi-Dimensional Damage Detection for Surfaces and Structures

Current designs for inflatable or semi-rigidized structures for habitats and space applications use a multiple-layer construction, alternating thin layers with thicker, stronger layers, which produces a layered composite structure that is much better at resisting damage. Even though such composite structures or layered systems are robust, they can still be susceptible to penetration damage. The ability to detect damage to surfaces of inflatable or semi-rigid habitat structures is of great interest to NASA. Damage caused by impacts of foreign objects such as micrometeorites can rupture the shell of these structures, causing loss of critical hardware and/or the life of the crew. While not all impacts will have a catastrophic result, it will be very important to identify and locate areas of the exterior shell that have been damaged by impacts so that repairs (or other provisions) can be made to reduce the probability of shell wall rupture. This disclosure describes a system that will provide real-time data regarding the health of the inflatable shell or rigidized structures, and information related to the location and depth of impact damage. The innovation described here is a method of determining the size, location, and direction of damage in a multilayered structure. In the multi-dimensional damage detection system, layers of two-dimensional thin film detection layers are used to form a layered composite, with non-detection layers separating the detection layers. The non-detection layers may be either thicker or thinner than the detection layers. The thin-film damage detection layers are thin films of materials with a conductive grid or striped pattern. The conductive pattern may be applied by several methods, including printing, plating, sputtering, photolithography, and etching, and can include as many detection layers that are necessary for the structure construction or to afford the detection detail level required. The damage is detected using a detector or sensory system, which may include a time domain reflectometer, resistivity monitoring hardware, or other resistance-based systems. To begin, a layered composite consisting of thin-film damage detection layers separated by non-damage detection layers is fabricated. The damage detection layers are attached to a detector that provides details regarding the physical health of each detection layer individually. If damage occurs to any of the detection layers, a change in the electrical properties of the detection layers damaged occurs, and a response is generated. Real-time analysis of these responses will provide details regarding the depth, location, and size estimation of the damage. Multiple damages can be detected, and the extent (depth) of the damage can be used to generate prognostic information related to the expected lifetime of the layered composite system. The detection system can be fabricated very easily using off-the-shelf equipment, and the detection algorithms can be written and updated (as needed) to provide the level of detail needed based on the system being monitored. Connecting to the thin film detection layers is very easy as well. The truly unique feature of the system is its flexibility; the system can be designed to gather as much (or as little) information as the end user feels necessary. Individual detection layers can be turned on or off as necessary, and algorithms can be used to optimize performance. The system can be used to generate both diagnostic and prognostic information related to the health of layer composite structures, which will be essential if such systems are utilized for space exploration. The technology is also applicable to other in-situ health monitoring systems for structure integrity.

Williams, Martha↗

Analysis of thermal and mechanical properties with inventory level of the molten salt storage tank in central receiver concentrating solar power plants

Molten salt thermal energy storage (TES) tanks ensure steady power output of concentrating solar power (CSP) plants; however, recent tank failures have highlighted the need for further analysis. Current studies primarily focus on analyzing the molten salt flow, heat transfer, and thermal efficiency. Additionally, research on the latest tank structures is limited and lacks newest experimental validation. This study measures temperature and molten salt inventory levels in the high-temperature tank at a 50 MW central receiver CSP plant, connected to the power grid in 2019. A multi-physics model was developed to evaluate thermal and mechanical properties of TES tanks by combining computational fluid dynamics and finite element modeling using real plant data. Heat loss, temperature, displacement, and stress distribution of the tank at different inventory levels were investigated. Results show that ambient air velocity near the tank roof reaches 2.14 m/s, much higher than 0.2 m/s near the wall. The temperatures of inventory fluid and tank are close, varying slightly at different levels due to thermal conduction and radiation. Because the heat loss strongly depends on temperature, the total tank loss remains nearly constant across inventory levels. Larger temperature gradients and thermal stresses are primarily localized along the tank floor edge and the air-salt interface. Notably, the maximum thermal stress at the tank edge is three times higher than that at the interface. The magnitude of total stress changes by less than 5 MPa with and without thermal load, indicating that high temperatures exert only a minor impact on tank stress. In contrast, thermal load significantly affects tank deformation, particularly at the roof edge, where values exceed 150 mm. Despite the large variation in molten salt levels, tank wall temperatures and displacements present a minor change, suggesting a weak correlation with inventory levels. In conclusion, the findings obtained in this study provide important insights on the TES tank that could be used to optimize tank design and operation strategies.

14 SOLAR ENERGY↗

Comprehensive Solutions for Integration of Solar Resources into Grid Operations

The need for proactive closed-loop integration of uncertainty information into system operations and probability-based controls is widely recognized, but rarely implemented in system operations. Proactive integration for this project means that the information concerning expected uncertainty ranges for net load and balancing requirements, including required balancing capacity, ramping and ramp duration characteristics, will be fed back into the generation commitment and dispatch algorithms to modify their performance so that potential shortages of these characteristics can be prevented. This basic, yet important, premise is the motivating factor for this project. The achieved project goal is to demonstrate the benefit of such a system. The project quantifies future uncertainties, predicts additional system balancing needs including the prediction intervals for capacity and ramping requirements of future dispatch intervals, evaluates the impacts of uncertainties on transmission including the risk of overloads and voltage problems, and explores opportunities for intra-hour generation adjustments helping to provide more flexibility for system operators. The resulting benefits culminate in more reliable grid operation in the face of increased system uncertainty and variability caused by solar power. The project identifies that solar power does not require special separate penetration level restrictions or penalization for its intermittency. Ultimately, the collective consideration of all sources of intermittency distributed over a wide area unified with the comprehensive evaluation of various elements of balancing process, i.e. capacity, ramping, and energy requirements, help system operators more robustly and effectively balance generation against load and interchange. This project showed that doing so can facilitate more solar and other renewable resources on the grid without compromising reliability and control performance. Efforts during the project included developing and integrating advanced probabilistic solar forecasts, including distributed PV forecasts, into closed –loop decision making processes. Additionally, new uncertainty quantifications methods and tools for the direct integration of uncertainty and variability information into grid operations at the transmission and distribution levels were developed and tested. During Phase 1, project work focused heavily on the design, development and demonstration of a set of processes and tools that could reliably and efficiently incorporate solar power into California’s grid operations. In Phase 2, connectivity between the ramping analysis tools and market applications software were completed, multiple dispatch scenarios demonstrated a successful reduction of overall uncertainty and an analysis to quantify increases in system operator reliability, and the transmission and distribution system uncertainty prediction tool was introduced to system operation engineers in a live webinar. The project met its goals, the experiments prove the advancements to methods and tools, when working together, are beneficial to not only the California Independent System Operator, but the benefits are transferable to other system operators in the United States.

14 SOLAR ENERGY↗

Scout Benchmark Scenarios for U.S. Building Energy and CO2 Emissions to 2050

Overview and Intended Use Cases: These scenarios establish a range of futures for U.S. buildings sector energy use and CO2 emissions to 2050 using Scout (scout.energy.gov), a reproducible and granular model of U.S. building energy use, emissions, and consumer costs developed by the U.S. national labs for the U.S. Department of Energy's Building Technologies Office (BTO). Scout benchmark scenario data are suitable for the following example use cases: setting high-level policy goals for the U.S. buildings sector to 2050 (e.g., X% building CO2 emissions reductions vs. 2005 levels by 2030, Y% reductions vs. 2005 levels by 2050); exploring the effects of key dynamics driving U.S. buildings sector energy and CO2 emissions to 2050 that could be affected by policy levers (e.g., raising minimum technology performance levels; accelerating electrification and/or retrofit rates; introducing breakthrough technologies to the market); determining priority segments (regions, building types, and end use/technology types) and sequencing of U.S. buildings sector energy and CO2 emissions reductions to 2050 under a given set of assumptions; and/or identifying the energy and emissions impacts or cost effectiveness of specific technologies or operational approaches of interest—in isolation or after considering competition with other measures in a scenario portfolio. Scenario Summary: A total of 8 scenarios explore the effects of changes across both the demand- and supply-side of building energy use on annual U.S. building energy use and CO2 emissions from 2022–2050. Scenarios are organized into three groups representing low, moderate, and best-case potentials for building decarbonization, respectively.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Machine-Learning-Based Mapping and Modeling of Solar Energy with Ultra-High Spatiotemporal Granularity

Despite the rapid growth of solar energy, we still lack a dynamic, high-fidelity database that tracks the spatiotemporal variations of solar PVs and their associated infrastructures across different places at a spatially resolved scale. The absence of such data presents a barrier to various applications such as solar PV growth projection, solar energy integration, solar incentive design, and climate risk assessment. In this project, we aim to bridge this gap by developing AI-based algorithms to extract granular information about solar PV installations and their associated infrastructures (i.e., distribution grids) from widely available unstructured data like remote sensing images and street views. As a result, we have built the Solar Energy Atlas, a fine-grained, large-scale geospatial overlay of distributed solar PVs and distribution grids. On top of it, we have advanced the understanding of solar adoption and distribution grid vulnerability to climate-induced extremes. Our major contributions can be summarized as follow: (1) By developing new AI algorithms, we have built the most comprehensive solar PV spatiotemporal database covering the entire US. This is the first time we obtained the exact GPS locations, size, subtype, and installation year information for rooftop solar PVs across the US. This database can be used for solar PV growth projection, solar energy integration, solar energy policy analysis and design, and spatially-resolved climate risk assessment. (2) Leveraging this database, we have uncovered the socioeconomic driving factors that are correlated with earlier onset of solar adoption and higher saturated adoption levels. We have identified the heterogeneity in the effects of different types of financial incentives on solar adoption and provided implications for tailoring incentive design based on local income levels to promote equitable solar adoption. (3) We have developed a distribution grid GIS mapping algorithm which can obtain granular geospatial and topology information about distribution grids using multi-modal open data, reducing the dependency on hard-to-obtain smart meter data of conventional approaches. It shows effectiveness in both the U.S. and Sub-Saharan Africa. Using this algorithm, we have uncovered the non-uniform vulnerability of distribution grids to wildfires in California in the aspects of undergrounding protection and Distributed Energy Resources (DER) preparedness. This has provided important implications for improving the affordability and equity of grid adaptation approaches. (3) We have made our produced database publicly available and provided user-friendly interface to enable various stakeholders and the general public to interact with the data. We have also integrated the produced data into the Data Commons platform to enable the public to access the data and correlate it with other location-specific characteristics simply using natural language as queries. The impact of our project is three-fold: (1) New algorithms for mapping solar PVs and distribution grids across space and time, which are open source to facilitate researchers and industry; (2) New databases of solar PVs and distribution grids that have been made publicly available for engineering, social, and policy applications; (3) New understandings and actionable insights on the potential approaches to promoting solar adoption and reducing energy infrastructure vulnerabilities. In this report, we start by discussing the project background and motivation (section 5), followed by the overview of project objectives (section 6). Results and discussion for each task are presented in section 7. Significant accomplishments are summarized in section 8. This report will be concluded by discussing the paths forwards (section 9), products (section 10), and team roles (section 11).

14 SOLAR ENERGY↗

Representing the Future Role of Hydropower and Pumped Storage Hydropower (PSH) in Electricity Planning Tools

Existing tools for long-term electric sector planning struggle to represent hydropower's nuanced site-specific technical and operating characteristics, which depend on technical specifications as well as water management practices and regulations. As a result, long-term planning models and tools insufficiently characterize hydropower value and incentives, and they cannot fully represent the role hydropower can play in a future electricity system that could include a high penetration of variable wind and solar generation, battery storage, and other low-carbon technologies. This presentation demonstrates the culmination of a multi-year effort to enhance hydropower representations in electricity planning models at the National Renewable Energy Laboratory (NREL), as part of the U.S. Department of Energy (USDOE) HydroWIRES Initiative. New modeling techniques are demonstrated using the NREL Regional Energy Deployment System (ReEDS), an open-access electric sector capacity expansion model used extensively in a wide range of technology deployment and integration analysis, including the 2016 USDOE Hydropower Vision. ReEDS uses a least-cost optimization approach to understand investment and operation of electricity generation, storage, and transmission technologies under future scenarios of electricity technology innovation, demand, policy, and other sectoral drivers. ReEDS was modified to better represent value and opportunities for both pumped storage hydropower (PSH) and hydropower systems without pumping. We incorporated a new national closed-loop PSH resource and cost assessment to explore new PSH deployment opportunities and added plant-level data to better represent the existing PSH fleet. New upgrade pathways enable opportunities for enhanced hydropower flexibility by adding pumps, upgrading dispatchability, increasing capacity, or increasing energy availability. The model was also modified to better represent the value of long-duration energy storage beyond diurnal time scales, allowing both hydropower and PSH to better balance energy supply and demand variations in high-renewable systems. These new features are demonstrated under reference and high-renewable futures and a range of sensitivity scenarios to understand which hydropower and PSH deployment and upgrade opportunities are the most attractive. These scenarios indicate potential for new closed-loop PSH deployment and for hydropower flexibility improvements to have important impacts on long-term electricity system emissions and economic outcomes. Increasing flexibility of the existing hydropower fleet can reduce the need to invest in new flexible grid technologies and help achieve decarbonization goals. Systems with sufficient energy storage could also be valuable for balancing seasonal differences in renewable energy availability, particularly from solar energy. The methods developed for ReEDS and subsequent scenario results reveal important considerations for future hydropower and grid system planning, and all data and code is freely available in a public code repository for use throughout the hydropower industry.

capacity expansion↗

OR-AGENT framework – Architecting electrified heavy-duty drayage applications

The widespread adoption of zero-emission vehicles in heavy-duty (HD) commercial freight transportation faces considerable technoeconomic challenges. For heavy-duty trucks, ensuring high uptime, cost parity with diesel, and safety standards is especially critical as these vehicles operate over long distances with heavy loads, where any downtime or off-nominal behaviors significantly impacts logistics, productivity, and the total cost of ownership. Unlike traditional diesel refueling, BEV charging infrastructure must be co-optimized with vehicle deployment, operational demands, and grid capacity to ensure cost-effective and reliable freight operations. However, the lack of a standardized ownership and service model has led to a fragmented approach—where commercial vehicle operators may invest in, own, and maintain both vehicle/batteries and charging/energy infrastructure. This disconnect may exclude energy service providers from the equation, forcing fleet operators to explore ‘behind-the-fence’ energy solutions that increase capital investment, operational downtime, overhead costs, and, in some cases, net carbon emissions. To address these issues, this study introduces OR-AGENT (Optimal Regional Architecture Generation for Efficient National Transport), a comprehensive modeling framework that integrates powertrain architectures, charging infrastructures, and energy backbone systems into a cohesive strategy. In this paper, OR-AGENT is applied to develop an interconnected systems architecture for energy efficiency and resiliency enhancement of heavy-duty drayage vehicles at the Port of Savannah, GA. This framework showcases an interconnected systems approach to electrifying heavy-duty drayage vehicles at the Port of Savannah, GA. The study assessed BEVs with 400–1200 kWh battery capacities, accounting for seasonal variations in weather and freight routing. A diverse charging mix (150 kW–1250 kW) was evaluated alongside grid capacity constraints, cost, and carbon intensity analysis, leading to the development of a strategic microgrid/Distributed Energy Resources (DER) deployment architecture to ensure a reliable and sustainable transition. However, the findings also highlight the need for alternative zero-emission solutions for remaining trips, such as larger batteries, electrified roadways, hydrogen powertrains, or net-zero emission fuels. In conclusion, the findings are incorporated into a Total Cost of Ownership (TCO) model to identify optimal architectures for an interconnected electrified ecosystem.

Commercial vehicles↗

2014-2018 Summary of NCAR activities in the Earth Energy Exascale System Model (E3SM) project

NCAR participation in E3SM activities as part of this funded collaborative project has been successful in leveraging the existing atmosphere model development experience from CESM scientists and applying it to initial v1 atmosphere model (EAM) development and analysis. NCAR partners collectively had many decades of experience in parameterization development, running and tuning coupled models and building the required software infrastructure to support ongoing model developments. Furthermore, collaboration between E3SM and CESM developers was of mutual benefit to both modeling endeavors. In the earlier periods of the project, participation in E3SM both complemented core critical path DOE activities and advanced individual parameterization development; including orographic drag, convection parameterization, convective gustiness and cloud and microphysical processes. Significant progress has been made implementing model capabilities for separating out the physics and dynamics grids, and providing the infrastructure for including orographic elevation class communication between the land and atmosphere models. Our activities working with the E3SM workflow and software engineering teams have established efficient protocols and infrastructure for the sharing of CESM and E3SM model codes of interest to both modeling groups, a large component of which is the mutual communication of common code bugs. As well as these specific project tasks all NCAR project members have been regular participants in atmosphere and coupled group telecons, as well as PI meetings. We have been fully engaged with and contributed to decisions regarding v1 atmosphere model developments, coupled model simulations, model tunings, and software engineering infrastructure. NCAR’s contribution to more recent E3SM development activities has centered on analysis of v1 release and pre-release simulations in order to address outstanding systematic biases and communicate climate improvements. Of particularly note is the work in understanding clouds and cloud feedbacks, shortcomings in ENSO and sub-seasonal variability; in particular the Madden Julian Oscillation (MJO). Contributions have been made to a number of papers that are currently published or in preparation detailing model performance in CMIP6-protocal experiments. They outline the simulations of mean climate, clouds and convection processes, convective gustiness, atmospheric blocking coupled climates. The contributions of NCAR’s funded activities to the E3SM atmosphere in the initial years of the project have had a positive impact on many aspects of the model simulations described in these papers.

58 GEOSCIENCES↗

Energy transport corridors: the potential role of Federal lands in states identified by the Energy Policy Act of 2005, section 368(b).

On August 8, 2005, the President signed the Energy Policy Act of 2005 (EPAct) into law. In Subtitle F of EPAct, Congress set forth various provisions that would change the way certain federal agencies (Agencies) coordinate to authorize the use of land for a variety of energy-related purposes. As part of Subtitle F of EPAct, Section 368 addresses the issue of energy transportation corridors on federal land for oil, gas, and hydrogen pipelines, as well as electricity transmission and distribution facilities. Because of the critical importance of improving the nation's electrical transmission grid, Congress recognized that electricity transmission issues should receive added attention when the Agencies address corridor location and analysis issues. In Section 368, Congress specifically directed the Agencies to consider the need for upgraded and new facilities to deliver electricity: In carrying out [Section 368], the Secretaries shall take into account the need for upgraded and new electricity transmission and distribution facilities to (1) improve reliability; (2) relieve congestion; and (3) enhance capability of the national grid to deliver electricity. Section 368 does not require the Agencies to consider or approve specific projects, applications for rights-of-way (ROWs), or other permits within designated energy corridors. Importantly, Section 368 does not direct, license, or otherwise permit any on-the-ground activity of any sort. If an applicant is interested in obtaining an authorization to develop a project within any corridor designated under Section 368, the applicant would have to apply for a ROW authorization and applicable permits. The Agencies would consider each application by applying appropriate project-specific reviews under requirements of laws and related regulations, including, but not limited to, the National Environmental Policy Act (NEPA), the Clean Water Act, the Clean Air Act, Section 7 of the Endangered Species Act (ESA), and Section 106 of the National Historic Preservation Act (NHPA). Under Section 368, Congress divided the United States into two groups of states: the 11 contiguous western states and the remaining states. Direction for energy transportation corridor analysis and selection in the 11 western states was addressed in Section 368(a) of EPAct, while direction for energy transportation corridor analysis and selection in all other states was addressed under Section 368(b) of EPAct. It was clearly the priority of Congress to conduct corridor location studies and designation first on federal lands in the western states. Under Section 368(a), the Agencies produced a programmatic environmental impact statement (EIS), Designation of Energy Corridors on Federal Land in the 11 Western States (DOE and DOI 2008), that was used in part as the basis for designating more than 6,000 mi (9,656 km) of energy transportation corridors on federal land in 11 western states. Under Section 368(a) of EPAct, Congress clearly stated the Agencies needed to (1) designate energy transportation corridors on federal land, (2) conduct the necessary environmental review of the designated corridors, and (3) incorporate the designated corridors into the appropriate land use plans. Congressional direction under Section 368(b) of EPAct differs from that provided under Section 368(a). Specifically, Section 368(b) requires the secretaries of the Agencies, in consultation with the Federal Energy Regulatory Commission (FERC), affected utility industries, and other interested persons, to jointly: (1) Identify corridors for oil, gas, and hydrogen pipelines and electricity transmission and distribution facilities on federal land in states other than the 11 western states identified under Section 368(a) of EPAct, and (2) Schedule prompt action to identify, designate, and incorporate the corridors into the applicable land use plans. While Section 368(a) clearly directs designation as a necessary first step for energy transportation corridors in the 11 western states, Section 368(b) directs the Agencies to first identify corridors and then schedule prompt action to identify, designate, and incorporate the corridors into applicable land use plans. To comply with the congressional direction provided in Section 368(b), the Agencies investigated corridor identification issues in the Section 368(b) states; this report to Congress provides information that could be relevant to possible future designation of energy corridors. Future designations, if appropriate and necessary, would occur when the Agencies undertake revisions and/or updates to land use plans that guide management decisions on lands located within individual administrative units, such as specific National Forests, National Parks, or Wildlife Refuges. At this time, the Agencies are not proposing any actions or decisions related directly or indirectly to designating energy corridors on federal land under Section 368(b) of EPAct.

08 HYDROGEN↗

Turbulent kinetics of a large wind farm and their impact in the neutral boundary layer

High-resolution large-eddy simulation of the flow over a large wind farm (64 wind turbines) is performed using the HIGRAD/FIRETEC-WindBlade model, which is a high-performance computing wind turbine–atmosphere interaction model that uses the Lagrangian actuator line method to represent rotating turbine blades. These high-resolution large-eddy simulation results are used to parameterize the thrust and power coefficients that contain information about turbine interference effects within the wind farm. Those coefficients are then incorporated into the WRF (Weather Research and Forecasting) model in order to evaluate interference effects in larger-scale models. In the high-resolution WindBlade wind farm simulation, insufficient distance between turbines creates the interference between turbines, including significant vertical variations in momentum and turbulent intensity. The characteristics of the wake are further investigated by analyzing the distribution of the vorticity and turbulent intensity. Quadrant analysis in the turbine and post-turbine areas reveals that the ejection motion induced by the presence of the wind turbines is dominant compared to that in the other quadrants, indicating that the sweep motion is increased at the location where strong wake recovery occurs. Regional-scale WRF simulations reveal that although the turbulent mixing induced by the wind farm is partly diffused to the upper region, there is no significant change in the boundary layer depth. The velocity deficit does not appear to be very sensitive to the local distribution of turbine coefficients. However, differences of about 5% on parameterized turbulent kinetic energy were found depending on the turbine coefficient distribution. Furthermore, turbine coefficients that consider interference in the wind farm should be used in wind farm parameterization for larger-scale models to better describe sub-grid scale turbulent processes.

17 WIND ENERGY↗