Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fringe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Holocene submergence of southern Long Island, New York

Samples of basal peat from south-central Long Island have been dated by the radiocarbon method, and a local curve of submergence has been obtained for the past 8,000 yr. The submergence curve indicates that from 7,000 and 3,000 yr BP the Long Island coast was being submerged at a rate of about 25 cm per 100 yr, a rate which slowed markedly to about 10 cm per 100 yr during the past 3,000 yr. Sea-level data for before 7,000 yr show considerable scatter. Samples from the fringing and mid-bay marsh areas of the Great South Bay taken at depths of -1.1 and -0.3 m MSL gave radiocarbon ages of about 1,015 and 300 yr, respectively. The inception of these marshes is estimated to have occurred at about 2,000 yr BP. It seems likely that the change from open lagoon to saltmarsh was initiated in the Great South Bay by a decrease in the rate of submergence at about 3,000 yr BP, which allowed sedimentation to build the floor of the lagoon to a level suitable for colonization by marsh grasses.

Rampino, M. R.↗

New phyllosilicate types in a carbonaceous chondrite matrix

Observations of new types of layer silicates in the crystalline regions of the matrix of a carbonaceous chondrite are reported. Ion-thinned sections of the Murchison meteorite were observed by high-resolution transmission electron microscopy. Images obtained of patterns of fringe spacings of 4.9 and 7.3 A are interpreted as resulting from ordered and disordered sequences of brucite-like and serpentine-like layers, respectively. The temperature and pressure conditions of phyllosilicate formation in the Murchison matrix are discussed in light of the suggested crysotile serpentine and brucite layers and evidence of Fe and Al in the layered intergrowths.

Mackinnon, I. D. R.↗

A two-dimensional white-light amplitude interferometer

A review of the applications of a point-symmetric, 180-degree, rotational shearing interferometer is given. Material includes, photographs of the Michelson stellar interferometer fringes from Alpha-Lyr, measures of amplitude of phase excursions in the atmosphere, and a measure of the order of interference of speckle patterns. New material includes unpublished double star speckle patterns to illustrate the isoplanatic patch, a measure of the time fluctuations in the earth's atmosphere, and measurements of the properties of a 256 channel linear reticon.

Breckinridge, J. B.↗

Assessing urbanized area expansion through the integration of Landsat and conventional data /79052/

An image base information system (IBIS) is utilized to integrate Landsat and census data for the purpose of mapping urban land and updating urbanized-area outer lines. IBIS is a subset of the video image communication and retrieval digital image processing system developed at JPL. IBIS is used to analyze three urban areas: Orlando, Florida; Seattle, Washington; and Boston, Massachusetts. In all three applications the primary objective is to map the expansion of urban land cover in the urban fringe. Pertinent tabular reports are produced.

Davis, J. B.↗

On-axis velocity component measurement with laser velocimeters

The application of Doppler shifted laser light to the measurement of the two velocity components normal to the optical axis of the system is relatively simple as compared to the measurement of the on-axis velocity component. The present paper deals with the reference-beam (local oscillator) technique and the dual-beam (fringe mode) technique, which have been developed for measuring the on-axis component. Some results obtained for the on-axis component are examined.

Neti, S.↗

Fourier emission infrared microspectrophotometer for surface analysis. I - Application to lubrication problems

A far-infrared interferometer was converted into an emission microspectrophotometer for surface analysis. To cover the mid-infrared as well as the far-infrared the Mylar beamsplitter was made replaceable by a germanium-coated salt plate, and the Moire fringe counting system used to locate the moveable Michelson mirror was improved to read 0.5 micron of mirror displacement. Digital electronics and a dedicated minicomputer were installed for data collection and processing. The most critical element for the recording of weak emission spectra from small areas was, however, a reflecting microscope objective and phase-locked signal detection with simultaneous referencing to a blackbody source. An application of the technique to lubrication problems is shown.

Lauer, J. L.↗

High-resolution spectrometrometry/interferometer

Modified double-pass interferometer has several features that maximize its resolution. Proposed for rocket-borne probes of upper atmosphere, it includes cat's-eye retroreflectors in both arms, wedge-shaped beam splitter, and wedged optical-path compensator. Advantages are full tilt compensation, minimal spectrum "channeling," easy tunability, maximum fringe contrast, and even two-sided interferograms.

Breckinridge, J. B.↗

Optical calibrator for TDL spectrometers

Two etalons and monochromator mode selector help calibrate spectrometer in selected laser mode. Technique accurately determines free spectral range of etalon. By establishing number of fringes between two modes, both of which have been calibrated with molecular line standards, one finds free spectral range with error inversely proportional to spectral interval between calibration points. Procedure establishes free spectral range of etalon without prior knowledge of its length or refractive index.

Jennings, D. E.↗

Efficient laser anemometer for intra-rotor flow mapping in turbomachinery

A fringe type laser anemometer is described. Features of the anemometer include; a rapid and efficient data acquisition process; a detailed real time graphic display of the data being accumulated; and input laser beam positioning that maximizes the size of the intrarotor region being mapped. Results are presented that demonstrate the anemometer's capability in flow mapping within a transonic axial flow compressor rotor. A velocity profile, derived from 30,000 measurements along 1000 sequential circumferential positions covering 20 blade passages, was obtained in 30 seconds. The use of fluorescent seed particles allowed flow measurements near the rotor hub and the casing window.

Powell, J. A.↗

Velocity servo for continuous scan Fourier interference spectrometer

A velocity servo for continuous scan Fourier interference spectrometer of the double pass retroreflector type having two cat's eye retroreflectors is described. The servo uses an open loop, lead screw drive system for one retroreflector with compensation for any variations in speed of drive of the lead screw provided by sensing any variation in the rate of reference laser fringes, and producing an error signal from such variation used to compensate by energizing a moving coil actuator for the other retroreflector optical path, and energizing (through a highpass filter) piezoelectric actuators for the secondary mirrors of the retroreflectors.

Schindler, R. A.↗

Visualization of impact damage of composite plates by means of the Moire technique

The phenomenological aspects of propagation damage due to low velocity impact on heavily loaded graphite-epoxy composite laminates were investigated using high speed photography coupled with the moire fringe technique. High speed moire motion records of the impacted specimens are presented. The results provide information on the time scale and sequence of the failure process. While the generation of the initial damage cannot always be separated temporally from the spreading of the damage, the latter takes place on the average with a speed on the order of 200 m/sec.

Knauss, W. G.↗

Gladstone-Dale constant for CF4

The Gladstone-Dale constant, which relates the refractive index to density, was measured for CF4 by counting fringes of a two-beam interferometer, one beam of which passes through a cell containing the test gas. The experimental approach and sources of systematic and imprecision errors are discussed. The constant for CF4 was measured at several wavelengths in the visible region of the spectrum. A value of 0.122 cu cm/g with an uncertainty of plus or minus 0.001 cu cm/g was determined for use in the visible region. A procedure for noting the departure of the gas density from the ideal-gas law is discussed.

Burner, A. W., Jr.↗

Atomic emission spectroscopy

The relationship between the Slater-Condon theory and the conditions within the atom as revealed by experimental data was investigated. The first spectrum of Si, Rb, Cl, Br, I, Ne, Ar, and Xe-136 and the second spectrum of As, Cu, and P were determined. Methods for assessing the phase stability of fringe counting interferometers and the design of an autoranging scanning system for digitizing the output of an infrared spectrometer and recording it on magnetic tape are described.

Andrew, K. H.↗

Astronomy using basic Mark 2 very long baseline interferometry

Two experiments were performed in April and September 1976 to determine precise positions of radio sources using conventional Mark 2 VLBI techniques. Four stations in the continental United States observed at a wavelength of 18 cm. The recording bandwidth was 2 MHz. The preliminary results using analyses of fringe rate and delay are discussed and the source positions compared with the results of other measurements.

Spencer, J. H.↗

Phase delay astrometry and its geodetic applications

The accuracy inherent in the fringe phase in the determination of source positions was calculated. It is shown that accuracy can be utilized by applying differencing techniques in order to circumvent such systematic effects as clock drift and delay due to the propagation media.

Wittels, J. J.↗

Development and performance of a laser heterodyne spectrometer using tunable semiconductor lasers as local oscillators

A diode laser based IR heterodyne spectrometer for laboratory and field use was developed for high efficiency operation between 7.5 and 8.5 microns. The local oscillator is a PbSSe tunable diode laser kept continuously at operating temperatures of 12-60 K using a closed cycle cooler. The laser output frequency is controlled and stabilized using a high precision diode current supply, constant temperature controller, and a shock isolator mounted between the refrigerator cold tip and the diode mount. Single laser modes are selected by a grating placed in the local oscillator beam. The system employs reflecting optics throughout to minimize losses from internal reflection and absorption, and to eliminate chromatic effects. Spectral analysis of the diode laser output between 0 and 1 GHz reveals excess noise at many diode current settings, which limits the infrared spectral regions over which useful heterodyne operation can be achieved. System performance has been studied by making heterodyne measurements of etalon fringes and several Freon 13 (CF3Cl) absorption lines against a laboratory blackbody source. Preliminary field tests have also been performed using the Sun as a source.

Glenar, D.↗

Photoelastic tests on models of thermal protection system for space shuttle orbiter

The thermal protection system (TPS) of the space shuttle orbiter vehicle, consisting of ceramic tile/adhesive/strain isolator pad/adhesive/aluminum substructure, was modeled photoelasticity. A highly sensitive photoelastic material was used in the models to show the nature of the stress-transfer between the strain isolation pad (SIP) and the ceramic tile through the RTV-adhesive layer. Isochromatic fringe patterns were obtained for models subjected to tension and combined tension and bending. Tests indicated that the load-transfer between the SIP and the photoelastic material occurred at discrete locations causing stress concentrations in the photoelastic material. Stress concentration factors of the order of 1.9 were measured, but as the observed photoelastic response was an integrated effect through the model thickness, the local stress concentration factors at the SIP/tile interface could be even higher.

Prabhakaran, R.↗

The table mountain 8-mm-wavelength interferometer

The system components, performance, and calibration of two element radio interferometer operating at 8.33 mm wavelength are discussed. The interferometer employs a 5.5 m and a 3 m diameter antenna on an east-west baseline of 60 or 120 m, yielding fringe spacings at transit of 28 or 14 in. respectively. The broad intermediate frequency bandpass of 100 to 350 MHz and the system noise temperature of 500 K provide high sensitivity for the measurement of continuum sources. The interferometer has been used for high resolution studies of the planets and the Sun, and it is currently being adapted to study solar flare emissions at high spatial and time resolution.

Janssen, M. A.↗