Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “focal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Two Year Cosmology Large Angular Scale Surveyor (CLASS) Observations: Long Timescale Stability Achieved with a Front-end Variable-delay Polarization Modulator at 40 GHz

The Cosmology Large Angular Scale Surveyor (CLASS) is a four-telescope array observing the largest angular scales (2≲ ℓ ≲ 200) of the cosmic microwave background (CMB) polarization. These scales encode information about reionization and inflation during the early universe. The instrument stability necessary to observe these angular scales from the ground is achieved through the use of a variable-delay polarization modulator as the first optical element in each of the CLASS telescopes. Here, we develop a demodulation scheme used to extract the polarization timestreams from the CLASS data and apply this method to selected data from the first 2 yr of observations by the 40 GHz CLASS telescope. These timestreams are used to measure the 1/f noise and temperature-to-polarization (T → P) leakage present in the CLASS data. We find a median knee frequency for the pair-differenced demodulated linear polarization of 15.12 mHz and a T → P leakage of <3.8 × 10 -4 (95% confidence) across the focal plane. We examine the sources of 1/f noise present in the data and find the component of 1/f due to atmospheric precipitable water vapor (PWV) has an amplitude of 203 ± 12 µK RJ $\sqrt{{s}}$ for 1 mm of PWV when evaluated at 10 mHz; accounting for ~17% of the 1/f noise in the central pixels of the focal plane. In conclusion, the low levels of T → P leakage and 1/f noise achieved through the use of a front-end polarization modulator are requirements for observing of the largest angular scales of the CMB polarization by the CLASS telescopes.

79 ASTRONOMY AND ASTROPHYSICS↗

Immunohistochemical analysis of cyclin A expression in Wilms tumor

Background: Cyclin A overexpression is found in a variety of human tumors and correlates with unfavorable outcome. We analyzed immunohistochemical expression of cyclin A in Wilms tumor (WT) in relation to clinicopathological characteristics, preoperative chemotherapy (PrOpChTh), and overall survival (OS). Methods: This retrospective study involved 43 patients who underwent nephrectomy from January 1996 to October 2010. Tumor stage and histological subtype were determined by revised Societé International d’Oncologie Pediatrique protocol, based on histological components/alterations caused by PrOpChTh, within the prognostic group of low, intermediate and high risk, and with criteria for anaplasia. The regressive/necrotic changes in total tumor mass of primary tumor and the proportion of epithelial, blastemal, and stromal components in the remaining viable tumor tissue were also determined. Cyclin A expression was evaluated by immunohistochemistry using a polyclonal rabbit, antihuman antibody (H-432). Results: Cyclin A overexpression was found in 34.3% of WTs, with higher frequency in tumors with epithelial (31.3%) and blastemal (37.1%) components than those with stromal component (17.7%). Regarding histological type, cyclin A overexpression was found most often in focal anaplasia (100%), stromal (60%), and diffuse anaplastic (66.7) WTs. The overexpression was also more frequent in stages 3 and 4 (77.8% and 66.7%, respectively) compared to tumors in stages 1 and 2 (13.3% and 12.5%, respectively; p = 0.004) in all components, as well as in blastemal component in stages 3 and 4 (77.8% and 66.7%, respectively) vs. stages 1 and 2 (13.3% and 25%, respectively, p = 0.009). Cyclin A overexpression in all components was 66.7% in WTs with metastasis and 31.3% in WTs without metastasis (p = 0.265, Fisher test). Log-rank testing revealed differences of OS regarding stage (p = 0.000), prognostic groups (p = 0.001), and cyclin A expression in blastemal component (p = 0.025). After univariate analysis, tumor stage (p = 0.001), prognostic group (p = 0.004), and cyclin A expression in blastemal component (p = 0.042) were significant prognostic factors for OS; however, after multivariate analysis, none of these factors were confirmed as independent predictors of survival. Discussion: This study showed that cyclin A overexpression might be associated with the development and progression of WT with anaplasia. Also, cyclin A overexpression was more often observed in advanced stages (3 and 4) of WT, in the group of high-risk WTs, and in focal and diffuse anaplasia WTs. There was no relation of cyclin A overexpression and metastatic ability of WT. Although this study has not confirmed the prognostic value of cyclin A overexpression, its association with unfavorable prognosis should be further evaluated. Copyright 2019 Radojevic-Škodric et al.

60 APPLIED LIFE SCIENCES↗

Radiant energy absorption enhancement in optical imaging systems

Reimaging system efficiently uses incident light and overcomes previous imaging detector problems. Optical system collects reflected and focal plane transmitted light and redirects it so it again impinges on focal plane in register with original image. Reimaging unabsorbed light increases light absorption and detector use probability.

Brown, R. M.↗

Comparison of photogrammetric and astrometric data reduction results for the wild BC-4 camera

The results of astrometric and photogrammetric plate reduction techniques for a short focal length camera are compared. Several astrometric models are tested on entire and limited plate areas to analyze their ability to remove systematic errors from interpolated satellite directions using a rigorous photogrammetric reduction as a standard. Residual plots are employed to graphically illustrate the analysis. Conclusions are made as to what conditions will permit the astrometric reduction to achieve comparable accuracies to those of photogrammetric reduction when applied for short focal length ballistic cameras.

Hornbarger, D. H.↗

Large Space Telescope (LST) preliminary analysis and design report, revision A

The design of a three meter class large space telescope (LST) is described. Mechanical design concepts were developed which integrate the separate spacecraft, telescope and instrument structures in such a way as to minimize their interaction during launch and orbital operation. The LST is of the Ritchey-Chretin type with a primary optics focal ratio of 3.12 to an overall focal ratio of 12.

Source record↗

Moonquakes.

Although the average rate of seismic energy release within the moon appears to be far below that of the earth, over 100 events believed to be moonquakes have been recorded by the two seismic stations installed on the lunar surface during Apollo missions 12 and 14. With few exceptions, the moonquakes occur at monthly intervals near times of perigee and apogee and show correlations with the longer-term (7-month) lunar gravity variations. The repeating moonquakes are believed to occur at not less than 10 different locations. However, a single focal zone accounts for 80 per cent of the total seismic energy detected. This active zone appears to be 600 kilometers south-southwest of the Apollo 12 and 14 sites and deep within the moon. Each focal zone must be small (less than 10 kilometers in linear dimension) and fixed in location over a 14-month period. Cumulative strain at each location is inferred. Thus, the moonquakes appear to be releasing internal strain of unknown origin, the release being triggered by tidal stresses.

Latham, G.↗

Lunar orbital photography of astronomical phenomena.

This paper reports further progress on photography of faint astronomical and geophysical phenomena accomplished during the recent Apollo missions. Command module pilots have been able to photograph such astronomical objects as the solar corona, zodiacal light-corona transition region, lunar libration region, and portions of the Milky Way. The methods utilized for calibration of the film by adaptation of the High Altitude Observatory sensitometer are discussed. Kodak 2485 high-speed recording film was used in both 35-mm and 70-mm formats. The cameras used were Nikon f/1.2 55-mm focal length and Hasselblad f/2.8 80-mm focal length. Preflight and postflight calibration exposures were included on both the flight and control films, corresponding to luminances extending from the inner solar corona to as faint as 1/10 of the luminance of the light of the night sky. The photographs obtained from unique vantage points available during lunar orbit are discussed.

Mercer, R. D.↗

Polarization of the solar corona.

A method of obtaining polarized photographs of the solar corona during total eclipse is described. The required equipment is a reflex viewing type camera with a lens of adequate focal length to give an image of the corona a few millimeters in diameter at the focal plane. A sheet of linear polarizing filter material is placed directly in front of the lens. The filter is mounted in such a way so as to permit a set of four exposures of equal length to be taken after totality begins. Since the light of the corona is highly polarized, the resultant set of photographs will show marked differences in the shape of the corona.

Feibelman, W. A.↗

Design and analysis of a star image motion compensator

The feasibility of designing and fabricating a small optical system to compensate for motions of a stellar field image on the focal plane of a large orbiting telescope is examined for a single-axis system. An all-reflecting two-mirror star image motion compensator maintains both a flat focal plane and image focus for one or more star images. Both theoretical and experimental evaluations show that only one adjustment is needed to aline the system since the change in focus is linearly related to the misalinements of all critical components. Results of an error analysis show that the focus error resulting from fabrication tolerances is very small compared to the adjustment capability of the system.

Romanczyk, K. C.↗

Far infrared astronomy

The research to develop a spectrometer to be used with a ground based telescope is described. Two liquid helium cooled infrared spectrometers were designed and built. The first, has a Cassegrain optical system and a variable focal length between 51.4 cm and 92.6 cm. It is capable of a resolution of 500. The second, has a focal length of 19.1 cm and has a resolution of 100. Both spectrometers have been operated at 10-30 microns. Sample spectra are included.

Houck, J. R.↗

Dual purpose optical instrument capable of simultaneously acting as spectrometer and diffractometer

A dual purpose optical instrument is described capable of simultaneously acting as a spectrometer and diffractometer to respectively perform elemental and structural analysis of an unknown sample. The diffractometer portion of the instrument employs a modified form of Seeman-Bohlin focusing which involves providing a line source of X-rays, a sample, and a detector, all on the same focal circle. The spectrometer portion of the instrument employs a fixedly mounted X-ray energy detector mounted outside of the plane of the focal circle.

Dasgupta, K.↗

Stellar figure sensor

A compilation of analytical and experimental data is presented concerning the stellar figure sensor. The sensor is an interferometric device which is located in the focal plane of an orbiting large space telescope (LST). The device was designed to perform interferometry on the optical wavefront of a single star after it has propagated through the LST. An analytical model of the device was developed and its accuracy was verified by an operating laboratory breadboard. A series of linear independent control equations were derived which define the operations required for utilizing a focal plane figure sensor in the control loop for the secondary mirror position and for active control of the primary mirror.

Peters, W. N.↗

Analytical study of the large orbital X-ray telescope imaging system

Results of an analytical study of the large orbital X-ray telescope (LOXT) are presented. The LOXT consists of a nested array of four conventional paraboloidal-hyperboloidal X-ray telescopes arranged with a common optical axis and a common focal plane. The composite nested array has a nominal effective focal length of 135.0 inches. The equations of the various mirror surfaces and the numerical values of the parameters in the defining equations are given in the technical specification sheets for the LOXT.

Foreman, J. W., Jr.↗

Development of a long wavelength spectrometer for the 24-channel multispectral scanner: Instructions for installation, start-up, and adjustment

The basic information is presented, which is required for start-up and operation of two long-wavelength focal-plane and cooler assemblies, including the amplifiers and temperature control systems. The focal plane systems, referred to as the long wavelength spectrometer (LWS) were developed for direct replacement of Arrays 3 and 4 into the multispectral scanner presently being operated by the NASA Manned Spacecraft Center Facility, and Laboratory Support Branch. The equipment is comprised of two major sub-assemblies: Array 3 with three indium antimonide detector channels and Array 4 with seven mercury doped Germanium detector channels. Each array is mounted on a cryogenic cooler and includes the vacuum housings, mounting hardware (x, y, z translation and rotation stages) and detector signal conditioning, temperature control and monitoring electronics. The two arrays were designed to operate independently and do not share common equipment (viz power supplies, housings, mounts, etc.).

Source record↗

Study of X-ray optics

The testing is reported of a polished Kanigen coated beryllium mirror in a soft X-ray telescope to be flown on a Skylark sounding rocket. This test involved inserting the telescope in a 220 foot long vacuum line and taking photographs of an X-ray resolution source. These photographs were then used to evaluate the performance of the telescope mirror as a function of distance from the focal plane and the angular distance off the telescope axis. A second test was made in which a point source was used to study the imaging characteristics by means of a pinhole and proportional counter placed in the telescope focal plane. A third test was conducted using a position sensitive detector. The efficiency and resolution was increased by polishing.

Froechtenigt, J. F.↗

Spectrometer integrated with a facsimile camera

This invention integrates a spectrometer capability with the basic imagery function of facsimile cameras without significantly increasing mechanical or optical complexity, or interfering with the imaging function. The invention consists of a group of photodetectors arranged in a linear array in the focal plane of the facsimile camera with a separate narrow band interference filter centered over each photodetector. The interference filter photodetector array is on a line in the focal plane of the facsimile camera along the direction of image motion due to the rotation of the facsimile camera's vertical mirror. As the image of the picture element of interest travels down the interference filter photodetector array, the photodetector outputs are synchronously selected and sampled to provide spectral information on the single picture element.

Burcher, E. E.↗

Multiplate focusing collimator

An appartus is described for scanning relatively small near sources of penetrating radiation to obtain the energy distribution thereof, wherein a collimator assembly is interposed between a radiation source and a radiation detector. The collimator assembly has a plurality of plates aligned in parallel planes with respect to a common axis normal to their centers. All the plates have similar random distribution of apertures. All apertures on each plate are the same size. The size of respective plates, the size of the apertures of said respective plates, and the spacing between said respective plates vary precisely according to a predetermined ratio to produce radiation channels which converge to a focal point. The radiation incident to the radiation detector is maximized when the focal point and the radiation source are co-incident.

Hoover, R. B.↗

Laser head for simultaneous optical pumping of several dye lasers

The invention is a laser head for simultaneous pumping several dye lasers with a single flash lamp. The laser head includes primarily a multi-elliptical cylinder cavity with a single flash lamp placed along the common focal axis of the cavity and with capillary tube dye cells placed along each of the other focal axes of the cavity. The inside surface of the cavity is polished. Hence, the single flash lamp supplies the energy to the several dye cells.

Mumola, P. B.↗