How [NOT] to Measure a Solar Cell to Get the Highest Efficiency

The multibillion-dollar photovoltaic (PV) industry sells products by the watt; the calibration labs measure this parameter at the cell and module level with the lowest possible uncertainty of 1-2 percent. The methods and procedures to achieve a measured 50 percent efficiency on a thin-film solar cell are discussed. This talk will describe methods that ignore procedures that increase the uncertainty. Your questions will be answered concerning 'Everything you Always Wanted to Know about Efficiency Enhancements But Were Afraid to Ask.' The talk will cover a step-by-step procedure using examples found in literature or encountered in customer samples by the National Renewable Energy Laboratory's (NREL's) PV Performance Characterization Group on how to artificially enhance the efficiency. The procedures will describe methods that have been used to enhance the current voltage and fill factor.

14 SOLAR ENERGY↗

Enhancing the thermal conductivity of ethylene-vinyl acetate (EVA) in a photovoltaic thermal collector

Samples of Ethylene-Vinyl Acetate (EVA) were doped with particles of Boron Nitride (BN) in concentrations ranging from 0-60% w/w. Thermal conductivity was measured using a Differential Scanning Calorimetery (DSC) technique. The thermal conductivity of parent EVA was increased from 0.24 W/m ⋅ K to 0.80 W/m ⋅ K for the 60% w/w sample. Two PV laminates were made; one using the parent EVA the other using EVA doped with 50% BN. When exposed to a one directional heat flux the doped laminate was, on average, 6% cooler than the standard laminate. A finite difference model had good agreement with experimental results and showed that the use of 60% BN composite achieved a PV performance increase of 0.3% compared to the standard laminate.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

EMAT enhanced dispersion of particles in liquid

Particulate matter is dispersed in a fluid material. A sample including a first material in a fluid state and second material comprising particulate matter are placed into a chamber. The second material is spatially dispersed in the first material utilizing EMAT force. The dispersion process continues until spatial distribution of the second material enables the sample to meet a specified criterion. The chamber and/or the sample is electrically conductive. The EMAT force is generated by placing the chamber coaxially within an induction coil driven by an applied alternating current and placing the chamber and induction coil coaxially within a high field magnetic. The EMAT force is coupled to the sample without physical contact to the sample or to the chamber, by another physical object. Batch and continuous processing are utilized. The chamber may be folded within the bore of the magnet. Acoustic force frequency and/or temperature may be controlled.

36 MATERIALS SCIENCE↗

Long-Life, Ultrahigh-Nickel Cathodes with Excellent Air Storage Stability for High-Energy Density Lithium-Based Batteries

With increased energy density and cost advantage, ultrahigh-nickel layered oxides (LiNi x M 1-x O 2 , x = 0.9 - 1.0) are becoming front-runner as cathodes for next-generation lithium-based batteries, yet their commercialization is blocked both by severe capacity fade and exponentially aggravated air degradation. Thus, it is imperative to find effective solutions to address these issues simultaneously. Here, a significant enhancement in both the cycling and air storage stability of the ultrahigh-Ni cathode LiNi 0.94 Co 0.06 O 2 is achieved via a distinctive phosphoric acid treatment strategy. The modified cathode displays remarkably improved capacity retention (from 36 % to 80 % after 1,000 cycles) and rate capability (from 0 to 105 mA h g -1 at 30C rate) in pouch cells. Impressively, the modified cathode, after air storage for 450 days, maintains the morphology and 92% of the initial capacity of the fresh sample with excellent cyclability. Comprehensive interphase and structural analyses reveal that the enhanced electrochemical performance is due to a highly stabilized electrode/electrolyte interphase that suppresses electrode corrosion and lattice reconstruction. The excellent air stability results from an adsorption-buffering effect enabled by phosphoric acid to air attack. Finally, the study demonstrates an engineering pathway to improve the cycling and air stability, facilitating the practical viability of high-capacity, affordable, ultrahigh-Ni cathodes in lithium-based batteries.

25 ENERGY STORAGE↗

Manufacturing techniques studies of ceramics by neutron and γ-ray radiography

In this study, the aim was to evaluate capabilities and constraints of radiographic imagery using thermal neutrons and gamma-rays as tools to identify the type of technique employed in ceramics manufacturing especially that used in prehistoric Brazilian pottery from Acre state. For this purpose, radiographic images of test objects made with clay of this region using both techniques - palette and rollers - have been acquired with a system comprised of a source of gamma-rays or thermal neutrons and a corresponding X-ray or neutron-sensitive Imaging Plate as detector. For the neutrongraphy samples were exposed to a thermal neutron flux of order of 10{sup 5}n.cm{sup −2}.s{sup −1} for 3 minutes at main port of Argonauta research reactor of the Instituto de Engenharia Nuclear - IEN/CNEN. The radiographic images using γ-rays from {sup 165}Dy (95 keV) and {sup 198}Au (412 keV) both produced at this reactor, have been acquired under an exposure time of a couple of hours. After acquisition, images have undergone a treatment to improve their quality through enhancement of their contrast, a procedure involving corrections of the beam divergence, sample shape and averaging of the attenuation map profile. Preliminary results show that difference between manufacturing techniques is better identified by radiography using low energy γ-rays from {sup 165}Dy rather than neutrongraphy or γ-rays from {sup 198}Au. Nevertheless, disregarding the kind of employed radiation, it should be stressed that feasibility to apply the technique is tightly tied to homogeneity of the clay itself and tempers due to their different attenuation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Targeted amplification for enhanced detection of biothreat agents by next-generation sequencing

Background: Historically, identification of causal agents of disease has relied heavily on the ability to culture the organism in the laboratory and/or the use of pathogen-specific antibodies or sequence-based probes. However, these methods can be limiting: Even highly sensitive PCR-based assays must be continually updated due to signature degradation as new target strains and near neighbors are sequenced. Thus, there has been a need for assays that do not suffer as greatly from these limitations and/or biases. Recent advances in library preparation technologies for Next-Generation Sequencing (NGS) are focusing on the use of targeted amplification and targeted enrichment/ capture to ensure that the most highly discriminating regions of the genomes of known targets (organism-unique regions and/or regions containing functionally important genes or phylogenetically-discriminating SNPs) will be sequenced, regardless of the complex sample background. Results: In the present study, we have assessed the feasibility of targeted sequence enhancement via amplification to facilitate detection of a bacterial pathogen present in low copy numbers in a background of human genomic material. Our results indicate that the targeted amplification of signature regions can effectively identify pathogen genomic material present in as little as 10 copies per ml in a complex sample. Importantly, the correct species and strain calls could be made in amplified samples, while this was not possible in unamplified samples. Conclusions: The results presented here demonstrate the efficacy of a targeted amplification approach to biothreat detection, using multiple highly-discriminative amplicons per biothreat organism that provide redundancy in case of variation in some primer regions. Importantly, strain level discrimination was possible at levels of 10 genome equivalents. Similar results could be obtained through use of panels focused on the identification of amplicons targeted for specific genes or SNPs instead of, or in addition to, those targeted for specific organisms (ongoing gene-targeting work to be reported later). Note that without some form of targeted enhancement, the enormous background present in complex clinical and environmental samples makes it highly unlikely that sufficient coverage of key pathogen(s) present in the sample will be achieved with current NGS technology to guarantee that the most highly discriminating regions will be sequenced.

59 BASIC BIOLOGICAL SCIENCES↗

Effects of rolling temperature and subsequent annealing on mechanical properties of ultrafine-grained Cu–Zn–Si alloy

The effects of rolling temperature and subsequent annealing on mechanical properties of Cu–Zn–Si alloy were investigated by using X-ray diffraction, transmission electron microscope, electron back scattered diffraction and tensile tests. The Cu–Zn–Si alloy has been processed at cryogenic temperature (approximately 77 K) and room temperature up to different rolling strains. It has been identified that the cryorolled Cu–Zn–Si alloy samples show a higher strength compared with those room temperature rolled samples. The improved strength of cryorolled samples is resulted from grain size effect and higher densities of dislocations and deformation twins. And subsequent annealing, as a post-heat treatment, enhanced the ductility. An obvious increase in uniform elongation appears when the volume fraction of static recrystallization grains exceeds 25%. The strength–ductility combination of the annealed cryorolled samples is superior to that of annealed room temperature rolled samples, owing to the finer grains, high fractions of high angle grain boundaries and twins. - Highlights: • An increase in hardness of Cu–Zn–Si alloy is noticed during annealing process. • Thermal stability is reduced in Cu–Zn–Si alloy by cryorolling. • An obvious enhancement in UE is noticed when fraction of SRX grains exceeds 25%. • A superior strength–ductility combination is achieved in the cryorolling samples.

36 MATERIALS SCIENCE↗

An efficient implementation of Forward-Backward Least-Mean-Square Adaptive Line Enhancers

An efficient implementation of the forward-backward least-mean-square (FBLMS) adaptive line enhancer is presented in this article. Without changing the characteristics of the FBLMS adaptive line enhancer, the proposed implementation technique reduces multiplications by 25% and additions by 12.5% in two successive time samples in comparison with those operations of direct implementation in both prediction and weight control. The proposed FBLMS architecture and algorithm can be applied to digital receivers for enhancing signal-to-noise ratio to allow fast carrier acquisition and tracking in both stationary and nonstationary environments.

Yeh, H.-G.↗

Mechanistic Insights Into Fatigue Life Enhancement of High‐Strength Steel via Ultrasonic Impact Treatment

In this work we explore the impact of Ultrasonic Impact Treatment (UIT) on the fatigue performance of high‐strength microalloyed steel commonly used in crankshaft applications. Building on prior observations of fatigue life improvement with UIT, this work focuses on unraveling the process–structure–performance relationships underpinning these enhancements. Microstructural analysis revealed significant grain refinement in the near‐surface layers, with deformation depth increasing at higher impact energies. This led to increased surface hardness and the development of deeper compressive residual stresses, particularly in samples treated with higher impact energy. Rotating bending fatigue testing showed a substantial improvement in fatigue life for UIT‐treated samples, with the endurance limit nearly doubling compared with untreated specimens. Fractographic analysis revealed a transition in crack initiation from surface defects in untreated samples to interior regions in UIT‐treated samples, characterized by the formation of noninclusion‐induced granular bright facets (GBFs). The observed fatigue enhancement is attributed to the synergistic effects of strain hardening and compressive residual stresses, which increase the surface crack threshold and promote interior crack initiation. This study provides new mechanistic insight into UIT‐induced fatigue resistance and interior failure behavior in high‐strength steels.

36 MATERIALS SCIENCE↗

Effect of NaOH Concentration and Adding Sequences on Structural and Magnetic Properties of Ni{sub 0.4}Co{sub 0.6}Fe{sub 2}O{sub 4} Nanopowders Prepared Via Co-precipitation Route

Ni{sub 0.4}Co{sub 0.6}Fe{sub 2}O{sub 4} nanopowders were prepared via the co-precipitation route followed by annealing treatment. The structural and magnetic properties of the as-synthesized samples were determined by XRD, FT-IR, TG-DSC, and PPMS measurements, respectively. The XRD patterns indicated a single-phase cubic spinel structure for all the Ni-Co ferrite samples, regardless of adding sequences of the reactants or NaOH concentration. The analysis of the XRD patterns revealed that the enhancement in lattice constant with increasing NaOH concentration is related to the prevention of oxidization of Co{sup 2+} ions in the Ni-Co ferrite lattice. The FT-IR spectra indicated that samples prepared in the B process have fewer impurities than those prepared in the A process. The enhancement in saturation magnetization with the increase in sodium hydroxide concentration could be attributed to the strengthening of super-exchange interaction between A and B sublattices, due to replacements of Co{sup 3+} ions (magnetic moment of 0 μ{sub B}) by Co{sup 2+} ions (magnetic moment of 3 μ{sub B}) at B sublattices. The obvious increase in the coercivity field with the increase in concentration of NaOH solutions can be interpreted in terms of enhancement of magneto-crystalline anisotropy that originated from gradual substitutions of Co{sup 3+} ions with Co{sup 2+} ions at the octahedral sites.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improved lipid analysis using a 2D-LC-MS system with a novel injection procedure

The aim of this study was to improve analysis of nonpolar lipidomics sample extracts using reversed phase (RP) chromatography. A 4/3/3 (v/v/v) mixture of methanol/methyl tert-butyl ether/chloroform (MeOH/MTBE/CHCl 3 , MMC) was chosen for sample extraction solvent based on its proven extraction capability for several lipid classes. To avoid carry over, loss of analytes and peak distortion the loops and all capillaries of the presented LC system were flushed and filled up with methanol until the analytical column. Here, the choice of methanol was due to its weak elution strength and being infinitely miscible with MMC and several other nonpolar solvents. This allowed injection of a 100 μl sample that was 20 μl nonpolar extraction solvent diluted fivefold with methanol. All lipids of 25 lipid classes were transferred quantitatively to the column head where the online dilution of methanol was carried out with aqueous eluent for focusing the lipid analytes. The weak elution strength of methanol prevented peak distortions. The consecutive reversed phase elution resulted in remarkably narrow peaks (full width at half maximum was 0.07–0.08 min typically) and enhanced sensitivity (limit of detection usually in sub nM region) because of increased sample injection volume and narrow peaks. Calibration and quality control samples made by diluting commercial lipid standards 200–50000 times confirmed the applicability of this approach both for targeted lipid quantification and for untargeted quantitative comparison of lipids from different sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phosphate-Induced Immobilization of Uranium in Hanford Sediments

Phosphate can be added to subsurface environments to immobilize U(VI) contamination. The efficacy of immobilization depends on the site-specific groundwater chemistry and aquifer sediment properties. Batch and column experiments were performed with sediments from the Hanford 300 Area in Washington State and artificial groundwater prepared to emulate the conditions at the site. Batch experiments revealed enhanced U(VI) sorption with increasing phosphate addition. X-ray absorption spectroscopy measurements of samples from the batch experiments found that U(VI) was predominantly adsorbed at conditions relevant to the column experiments and most field sites (low U(VI) loadings, <25 μM), and U(VI) phosphate precipitation occurred only at high initial U(VI) (>25μM) and phosphate loadings. While batch experiments showed the transition of U(VI) uptake from adsorption to precipitation, the column study was more directly relevant to the subsurface environment because of the high solid:water ratio in the column and the advective flow of water. In column experiments, nearly six times more U(VI) was retained in sediments when phosphate-containing groundwater was introduced to U(VI)-loaded sediments than when the groundwater did not contain phosphate. This enhanced retention persisted for at least one month after cessation of phosphate addition to the influent fluid. Sequential extractions and laser-induced fluorescence spectroscopy of sediments from the columns suggested that the retained U(VI) was primarily in adsorbed forms. These results indicate that in situ remediation of groundwater by phosphate addition provides lasting benefit beyond the treatment period via enhanced U(VI) adsorption to sediments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhanced thermoelectric performance in Cd doped CuInTe{sub 2} compounds

CuIn{sub 1−x}Cd{sub x}Te{sub 2} materials (x = 0, 0.02, 0.05, and 0.1) are prepared using melting-annealing method and the highly densified bulk samples are obtained through Spark Plasma Sintering. The X-ray diffraction data confirm that nearly pure chalcopyrite structures are obtained in all the samples. Due to the substitution of Cd at In sites, the carrier concentration is greatly increased, leading to much enhanced electrical conductivity and power factor. The single parabolic band model is used to describe the electrical transport properties of CuInTe{sub 2} and the low temperature Hall mobility is also modeled. By combing theoretical model and experiment data, the optimum carrier concentration in CuInTe{sub 2} is proposed to explain the greatly enhanced power factors in the Cd doped CuInTe{sub 2}. In addition, the thermal conductivity is reduced by extra phonon scattering due to the atomic mass and radius fluctuations between Cd and In atoms. The maximum zTs are observed in CuIn{sub 0.98}Cd{sub 0.02}Te{sub 2} and CuIn{sub 0.9}Cd{sub 0.1}Te{sub 2} samples, which are improved by over 100% at room temperature and around 20% at 600 K.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterization of Shear Properties for APO/MBI Syntactic Foam

Triaxial compression testing is a means for mechanical characterization of a material. A unique feature of the triaxial compression test is the application of two different magnitudes of compressive pressures on the material simultaneously. The material behavior under these different compressive pressures can be monitored over time. Several important characteristics of the material, such as stress yield values and the shear failure envelope may then be determined. Also mechanical properties such as Poisson’s ratio, Young’s modulus and bulk modulus can be determined from the triaxial compression test. The triaxial compression test was employed in this investigation to characterize the shear behavior, shear failure envelope, and mechanical properties of a syntactic foam. Los Alamos National Laboratory (LANL) supplied a total of 36 samples of APO-BMI syntactic foam to the University of New Mexico, Department of Civil Engineering for testing between December 2003 and May 2004. Each sample had a diameter of 1.395±0.005 in. (3.543±0.013cm.) and a length of 2.796±0.004 in. (7.102±0.010 cm.). The samples had an average density of 0.295 g/cm3. Additional information about the material tested in this investigation can be found in the “Specimen Description” section contained in Chapter 1. The nomenclatures used in this study is presented in Chapter 1. In addition to designing and implementing triaxial compression tests capable of up to 2,000 psi. confining pressure (minor principal stress) and roughly 13,000 psi. in axial pressure (major principal stress), a pure tension test was designed and conducted on the foam material. The purpose of this pure tension test was to obtain maximum tensile stress values to enhance the characterization of the shear envelope in the stress space. The sampling procedure and specimen preparation for a standard test can be found in the American Society for Testing Materials (ASTM) D 5379/ D 5379 – 93. The above tests mentioned and their procedures are discussed in Chapter 2. Chapter 2 contains the types of tests performed and the apparatus used for testing the material. Chapter 2 also has a brief explanation of the equipment and the procedures used for conducting the tests. In Chapter 3, the material characteristics and mechanical properties obtained from the tests are described; composite plots of deviatoric vs. mean stress and deviatoric stress vs. longitudinal strain are also included. The plots of deviatoric stress vs. mean stress clearly identify the shear envelope for the material. Chapter 4 summarizes the vital information obtained from the tests and the conclusions made. All the necessary plots and the data generated during the testing have been included in the Appendix. The information in the appendix includes plots of: Strain vs. Time, Stress vs. Time, Stress vs. Strain, Mean Stress vs. Volumetric Strain, Lateral Strain vs. Longitudinal Strain, and q vs. p. Bulk modulus, Poisson’s ratio, and Young’s modulus are displayed in the appropriate plots in each appendix.

36 MATERIALS SCIENCE↗

Are young stars always associated with cold massive disks? A CO and millimeter interferometric continuum survey

The results of a combined millimeter-spectral-line and continuum survey of cold far-infrared sources selected to favor embedded young stars in the Galaxy are presented. The spectral-line observations were performed with the 5 meter antenna of the University of Texas Millimeter-Wave Observatory. High resolution continuum observations were obtained with the Owens Valley (OVRO) Millimeter-Wave Interferometer. The goal of the survey was to gain insight into the mass, temperature, and distribution of cold dust which envelopes stars during the earliest stages of their evolution. The first phase of our survey involved 1.2 arcmin resolution observations of CO-12 and CO-13 emission lines toward each source. All but two sources had detectable CO emission. We found that 40% of the sources appear to be associated with star formation as evidenced by the presence of enhanced CO-12 line widths or broad wings. At least five of these objects are associated with bipolar molecular outflows. The second phase of our survey involves high resolution 2.7 mm continuum observations with 3 interferometer baselines ranging from 15 to 55 m in length. Preliminary results indicate that about 25% of the sources in our sample have detectable continuum emission on scales less than 30 arcsec. The high percentage of sources with enhanced CO-12 line widths or broad wings indicates that a significant fraction of our samples, 40%, are likely to be young stars. The lower detection percentage in the continuum observations, 25%, suggest that such objects are not always surrounded by large concentrations of gas and dust. The continuum detection percentage for actual dust emission could be lower than that given above since emission from ionized gas could be responsible for the observed 2.7 mm emission in some objects. To get an understanding of the type of object detected in our survey, a map of one of the survey sources, L1689N, has been made using the OVRO mm interferometer.

Mundy, L. G.↗

An innovative accident tolerant LWR fuel rod design based on uranium-molybdenum metal alloy

The US Department of Energy is developing a uranium-molybdenum metal alloy Enhanced Accident Tolerant Fuel concept for Light Water Reactor applications that provides improved fuel performance during normal operation, anticipated operational occurrences, and postulated accidents. The paper is organized as follows. First, an overview of the design features of the U-Mo fuel concept is summarized, including the key attributes and technical challenges to be addressed through the research and development program. Second, recent results are provided on the triple extrusion of a depleted U-Mo fuel rodlet with a niobium liner and SS-316 cladding. A status is presented next on the high temperature water corrosion testing of short samples with pre-drilled cladding defects. Lastly, an assessment of the enhanced accident tolerance features is discussed that highlights the key performance attributes of the U-Mo fuel rod design. Scoping calculations have identified that the reduced stored energy of the U-Mo fuel at the initiation of a LOCA event may reduce core temperatures below 500-600 Celsius degrees during the early phase of the LOCA event. These preliminary evaluations find that the U-10Mo fuel design concept has many beneficial features that can meet or improve conventional LWR fuel performance requirements under normal operation, anticipated operational occurrences (AOOs) and postulated accidents.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A PCR Based Microbial Monitoring Alternative Method of Detection and Identification of Microbes Aboard ISS

Previous research has shown that microorganisms and potential human pathogens have been detected on the International Space Station (ISS) with additional introduction of new microflora occurring with every exchange of crew or addition of equipment and supplies. These microbes are readily transferred between crew and subsystems (i.e. ECLSS, environmental control and life support systems). As this can be detrimental to astronaut health and optimal performance of ISS systems, monitoring of systems such as ECLSS to include identification of microbial contaminants could prevent adverse effects on human health and life support systems. Current monitoring on ISS is laborious and utilizes culture based methods followed by sample return to Earth for complete analysis. Future, long-distance spaceflight missions will require real-time monitoring capabilities that enable efficient and rapid assessments of the microbial environment allowing for expedited decisions and more targeted response to cope with anomalies. Polymerase chain reaction (PCR), a molecular microbial monitoring method was chosen and numerous PCR instruments investigated for their potential to perform in microgravity conditions. Using ISS as a test bed for PCR verification in microgravity will enable NASA to assess whether molecular based microbiological sensors may be components of reliable, closed-loop life support and habitation systems in spacecraft, enhancing infrastructure capabilities through increased efficiency, reliability, and time savings by enabling sample analysis on orbit. NASA selected the Water Monitoring Suite as one of the rapid spaceflight hardware demonstration activities utilizing a streamlined process to minimize the time required to fly experimental flight hardware. The RAZOR EX (BioFire Defense, Salt Lake City, UT) system was part of the water monitoring suite and is a commercial off-the-shelf (COTS) real-time PCR instrument designed for field work. The RAZOR EX was originally designed for Department of Defense (DoD) under a small business innovative research (SBIR) grant and is ruggedized, compact and provides a rapid, sample to answer in less than an hour. PCR assays using a fluorescent probe were optimized and spiked with known concentrations of DNA (Pseudomonas aeruginosa) ranging from 0.002 to 20 ng. PCR reagents were lyophilized and configured in customized pouches and tested for flight readiness. Three types of water were used to rehydrate the reagents and demonstrate the fidelity of the PCR reaction in microgravity. Molecular grade deionized water served as a control while filtered and unfiltered ISS potable water served to test for chemical or biological inhibitors. All three types were compared to parallel ground test results. Nine tests were run on ISS (3 of each water type) and the critical threshold cycle (Ct) was compared to parallel ground tests completed at Kennedy Space Center, FL and Johnson Space Center, TX. All concentrations of Pseudomonas aeruginosa DNA were detected. A comparison of the Ct produced in real time PCR indicated similarity between flight and ground samples. There appeared to be no significant difference between flight or ground PCR reactions or between any of the three water types. This testing demonstrated the ability to perform molecular testing during spaceflight operations with similar sensitivity. It will allow for future ground development of molecular protocols and minimize the need for spaceflight testing. Future testing will include development of additional targets including environmental and health related organisms.

Christina Khodadad↗

Absorption of Solar Radiation by the Cloudy Atmosphere: Further Interpretations of Collocated Aircraft Measurements

We have extended the interpretations made in two prior studies of the aircraft shortwave radiation measurements that were obtained as part of the Atmospheric Radiation Measurements (ARM) Enhanced Shortwave Experiments (ARESE). These extended interpretations use the 500 nm (10 nm bandwidth) measurements to minimize sampling errors in the broadband measurements. It is indicated that the clouds present during this experiment absorb more shortwave radiation than predicted by clear skies and thus by theoretical models, that at least some (less than or equal to 20%) of this enhanced cloud absorption occurs at wavelengths less than 680 nm, and that the observed cloud absorption does not appear to be an artifact of sampling errors nor of instrument calibration errors.

Cess, R. D.↗