Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrical switches”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

The NASA space power technology program

NASA has a broad technology program in the field of space power. This paper describes that program, including the roles and responsibilities of the various NASA field centers and major contractors. In the power source area, the paper discusses the SP-100 Space Nuclear Power Project, which has been under way for about seven years and is making substantial progress toward development of components for a 100-kilowatt power system that can be scaled to other sizes. This system is a candidate power source for nuclear electric propulsion, as well as for a power plant for a lunar base. In the energy storage area, the paper describes NASA's battery- and fuel-cell development programs. NASA is actively working on NiCd, NiH2, and lithium batteries. A status update is also given on a U.S. Air Force-sponsored program to develop a large (150 ampere-hour) lithium-thionyl chloride battery for the Centaur upper-stage launch vehicle. Finally, the area of power management and distribution (PMAD) is addressed, including power system components such as solid-state switches and power integrated circuits. Automated load management and other computer-controlled functions offer considerable payoffs. The state of the art in space power is described, along with NASA's medium- and long-term goals in the area.

Stephenson, R. Rhoads↗

Magnetic Launch Assist: NASA's Vision for the Future

With the ever-increasing cost of getting to space and the need for safe, reliable, and inexpensive ways to access space. The National Aeronautics and Space Administration (NASA) is taking a look at technologies that will get us there. One of these technologies is Magnetic Launch Assist (MagLev). This is the concept of using both magnetic levitation and magnetic propulsion to provide an initial velocity by using electrical power from ground sources. The use of ground generated electricity can significantly reduce operational costs over the consumables necessary to attain the same velocity. The technologies to accomplish this are both old and new. The concept of MagLev has been around for a long time and several MagLev Trains have been developed. Where NASA's MagLev diverges from the traditional train is in the immense amount of power required to propel this vehicle to 183 meters per second in less than 10 seconds. New technologies or the upgrade of existing technologies will need to be investigated in the areas of energy storage and power switching. An added difficulty is the separation of a very large mass (the space vehicle) from the track and the aerodynamics of that vehicle while on the track. These are of great concern and require considerable study and testing. NASA's plan is to mature these technologies in the next 25 years to achieve our goal of launching a full sized space vehicle for under $300 a kilogram.

Jacobs, William A.↗

Total cost of ownership of vehicle electrification and fuel switching options for light-duty and heavy-duty vehicles

Projecting the transition from combustion engines to battery-based powertrains is complex becuase it involves numerous interdependent decisions. This study estimates total cost of ownership (TCO) to assess the economic viability of powertrain electrification, focusing exclusively on advances in vehicle and fuel technologies. Under two bounding technology-progress scenarios, we develop vehicle designs and fuel cost trajectories, which serve as inputs to TCO projections for selected classes from 2021 to 2050. We analyzed a small sport utility vehicle (SUV) to represent the light-duty vehicle (LDV) sector, and four medium- and heavy-duty vehicle (MHDV) classes: Class 6 box delivery, Class 8 drayage, Class 8 long-haul, and Class 8 transit bus. For each class, we compared the TCO of battery electric vehicles (BEVs) and fuel cell hybrid electric vehicles (FCHEVs) against conventional internal combustion engine vehicles (ICEVs). The results show that modern ICEVs generally have lower TCO; however, BEVs and FCHEVs could match or have lower TCOs than ICEVs over time, depending on technological progress. In LDVs, BEV300 is projected to deliver the lowest TCO by 2050, particularly under the high-progress scenario. In MHDVs, both BEVs and FCHEVs could become more cost-competitive than ICEVs by 2050 in the high-progress case. Beyond these results, the findings suggest further investigation is warranted for BEV charging infrastructure, FCHEV hydrogen refueling infrastructure, and MHDV charging strategies. In conclusion, these factors could reduce the fuel-cost share of TCO and enhance the competitiveness of BEVs and FCHEVs relative to ICEVs.

Battery electric vehicle↗

Investigation of Dynamic Temperature-Sensitive Electrical Parameters for Medium-Voltage Low-Current Silicon Carbide and Silicon Devices

This paper presents five dynamic temperature-sensitive electrical parameters (TSEPs) for the medium-voltage silicon carbide (SiC) and silicon (Si) devices. The theoretical temperature dependence of these parameters is analyzed. A test platform that enables to implement the temperature relevant dynamic characterization is developed. The tested TSEPs are summarized in terms of their relationship with junction temperature, drain/collector current, DC voltage, and external gate resistance. The comparison between the 3 kV 12 A Si IGBT and 3.3 kV 5 A SiC MOSFET with the identical TO-263 package is conducted. The results verify that the turn-off drain-source voltage switching rate achieves better thermal sensitivity for medium-voltage low-current SiC MOSFETs compared with Si IGBTs. Both the turn-on and turn-off delay time exhibit better thermal linearity for the two devices. The turn-off delay time further achieves five times better thermal sensitivity than the turn-on delay time for investigated medium-voltage SiC MOSFETs.

Ni, Ze↗

Design of BLDC Motor Diagnostic Device Based on Surge Test for Phase to Ground Fault

BLDC motor is essential in the industrial world, especially it been used for an electric vehicle. The benefit of using BLDC motor is that it has high rate efficiency and low mechanical losses. However, to know the isolation condition of winding and increase reliability, it needs to be tested. With the implementation of surge test based fault detection device of BLDC motor, the condition of BLDC motor can be monitored and maintained according to analysis of its condition. The surge test method used because it is sensitive in detecting the initial damage in the isolation failure process on stator winding. A surge voltage is generated from the Cockroft-Walton and switching circuit with capacitors. The result is analyzed using Error Area Ratio (EAR). The test result shows that the higher the value of resistance and inductance, the smaller the frequency of the surge wave. When the BLDC motor in a parallel short circuit condition, the threshold value of the EAR test-reff has a minimum value of 5.28%, an average of 13.52%, and a maximum of 28.55%.

BLDC motor↗

A Review on Protection Challenges on Transmission Lines Connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses. Utilities, university researchers, research institutes, and relay manufacturers have performed studies to investigate different aspects of high IBR penetration. Almost all studies support 1) creating international and national standards to regulate the IBRs, 2) revising engineering tools to address shortcomings, and 3) adjusting the protective relay settings to resolve protection problems. This paper summarizes the studies and research conducted in recent years to quantify the impact of IBR penetration on transmission line protection and to identify potential solutions to improve the dependability and reliability of grid protection systems.

14 SOLAR ENERGY↗

A review on protection challenges of Transmission Lines connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses.

14 SOLAR ENERGY↗

NASA Tech Briefs, June 2014

Topics include: Real-Time Minimization of Tracking Error for Aircraft Systems; Detecting an Extreme Minority Class in Hyperspectral Data Using Machine Learning; KSC Spaceport Weather Data Archive; Visualizing Acquisition, Processing, and Network Statistics Through Database Queries; Simulating Data Flow via Multiple Secure Connections; Systems and Services for Near-Real-Time Web Access to NPP Data; CCSDS Telemetry Decoder VHDL Core; Thermal Response of a High-Power Switch to Short Pulses; Solar Panel and System Design to Reduce Heating and Optimize Corridors for Lower-Risk Planetary Aerobraking; Low-Cost, Very Large Diamond-Turned Metal Mirror; Very-High-Load-Capacity Air Bearing Spindle for Large Diamond Turning Machines; Elevated-Temperature, Highly Emissive Coating for Energy Dissipation of Large Surfaces; Catalyst for Treatment and Control of Post-Combustion Emissions; Thermally Activated Crack Healing Mechanism for Metallic Materials; Subsurface Imaging of Nanocomposites; Self-Healing Glass Sealants for Solid Oxide Fuel Cells and Electrolyzer Cells; Micromachined Thermopile Arrays with Novel Thermo - electric Materials; Low-Cost, High-Performance MMOD Shielding; Head-Mounted Display Latency Measurement Rig; Workspace-Safe Operation of a Force- or Impedance-Controlled Robot; Cryogenic Mixing Pump with No Moving Parts; Seal Design Feature for Redundancy Verification; Dexterous Humanoid Robot; Tethered Vehicle Control and Tracking System; Lunar Organic Waste Reformer; Digital Laser Frequency Stabilization via Cavity Locking Employing Low-Frequency Direct Modulation; Deep UV Discharge Lamps in Capillary Quartz Tubes with Light Output Coupled to an Optical Fiber; Speech Acquisition and Automatic Speech Recognition for Integrated Spacesuit Audio Systems, Version II; Advanced Sensor Technology for Algal Biotechnology; High-Speed Spectral Mapper; "Ascent - Commemorating Shuttle" - A NASA Film and Multimedia Project DVD; High-Pressure, Reduced-Kinetics Mechanism for N-Hexadecane Oxidation; Method of Error Floor Mitigation in Low-Density Parity-Check Codes; X-Ray Flaw Size Parameter for POD Studies; Large Eddy Simulation Composition Equations for Two-Phase Fully Multicomponent Turbulent Flows; Scheduling Targeted and Mapping Observations with State, Resource, and Timing Constraints;

Source record↗

A Review on Protection Challenges of Transmission Lines Connected to Inverter-Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses

14 SOLAR ENERGY↗

Vertical nanoscale strain-induced electronic localization in epitaxial La2/3Sr1/3MnO3 films with ZrO2 nanopillar inclusions

Abstract Unusual electrical transport properties associated with weak or strong localization are sometimes found in disordered electronic materials. Here, we report experimental observation of a crossover of electronic behavior from weak localization to enhanced weak localization due to the spatial influence of disorder induced by ZrO 2 nanopillars in (La 2/3 Sr 1/3 MnO 3 ) 1− x :(ZrO 2 ) x ( x = 0, 0.2, and 0.3) nanocomposite films. The spatial strain regions, identified by scanning transmission electron microscopy and high-resolution x-ray diffraction, induce a coexistence of two-dimentional (2D) and three-dimentional (3D) localization and switches to typical 2D localization with increasing density of ZrO 2 pillars due to length scale confinement, which interestingly accords with enhancing vertically interfacial strain. Based on the excellent agreement of our experimental results with one-parameter scaling theory of localization, the enhanced weak localization exists in metal range close to the fixed point. These films provide a tunable experimental model for studying localization in particular the transition regime by appropriate choice of the second epitaxial phase. Graphical Abstract

36 MATERIALS SCIENCE↗

Environmental Evaluation of Gas Switching Reforming for Low Carbon Hydrogen: A Power-to-X Study

Gas Switching Reforming for hydrogen production (GSR-H2) offers a promising pathway for producing low-carbon hydrogen at scale, with significant implications for Power-to-X (PtX) systems that rely on clean hydrogen as a feedstock for synthetic fuels and chemicals. GSR-H2 integrates inherent carbon capture and thermal self-sufficiency, positioning it as an efficient alternative to conventional steam methane reforming (SMR), proton exchange membrane (PEM) electrolysis, and chemical looping reforming (CLR). Unlike SMR, GSR-H2 avoids external natural gas combustion by leveraging exothermic redox cycles to generate process steam and recover electricity internally. Its innovative reactor design consolidates all reforming stages within a single reactor cluster, eliminating the need for solid circulation found in CLR, thereby reducing capital costs and improving system reliability and scalability. This presentation describes the first environmental life cycle assessment (LCA) of GSR-H2, evaluating its environmental performance across U.S. grid and renewable energy scenarios. In a renewables-powered configuration, GSR-H2 achieves a global warming potential (GWP) of 2.77 kg CO2 equivalent per kg H2, substantially lower than SMR (10.4 kg) and competitive with PEM electrolysis (1.85 kg) and CLR (1.84 kg). Results across additional impact categories, including air quality and water use, support GSR-H2’s role as a complementary hydrogen source in PtX applications. Its reduced environmental burden, thermal integration, and simplified scale-up potential make GSR-H2 a viable contributor to net-zero PtX systems, particularly where renewable energy is abundant and electricity-intensive hydrogen production faces economic or infrastructure constraints.

03 NATURAL GAS↗

Independent Orbiter Assessment (IOA): Analysis of the electrical power distribution and control subsystem, volume 1

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results corresponding to the Orbiter Electrical Power Distribution and Control (EPD and C) hardware. The EPD and C hardware performs the functions of distributing, sensing, and controlling 28 volt DC power and of inverting, distributing, sensing, and controlling 117 volt 400 Hz AC power to all Orbiter subsystems from the three fuel cells in the Electrical Power Generation (EPG) subsystem. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode. Of the 1671 failure modes analyzed, 9 single failures were determined to result in loss of crew or vehicle. Three single failures unique to intact abort were determined to result in possible loss of the crew or vehicle. A possible loss of mission could result if any of 136 single failures occurred. Six of the criticality 1/1 failures are in two rotary and two pushbutton switches that control External Tank and Solid Rocket Booster separation. The other 6 criticality 1/1 failures are fuses, one each per Aft Power Control Assembly (APCA) 4, 5, and 6 and one each per Forward Power Control Assembly (FPCA) 1, 2, and 3, that supply power to certain Main Propulsion System (MPS) valves and Forward Reaction Control System (RCS) circuits.

Schmeckpeper, K. R.↗

SLR 2000

SLR 2000 is a concept for a totally automated subcentimeter SLR system presently being studied at GSFC. If funding permits, a prototype would be installed and tested at the Goddard Geophysical and Astronomical Observatory (GCAO) in FY98 and a small number of automated stations would be fielded by the year 2000. Unlike present systems, the "SLR 2000" system is being designed to: 1) operate autonomously without the need for onsite operators; 2) present no hazards (i.e., optical, electrical, and/or chemical) to personnel in the vicinity or to overflying aircraft; and 3) have a mean time between failures (MTBF) of at least three months. It is assumed that the systems are located at "friendly" sites where some level of security is provided and where certain low level service functions (e.g. commercial power, communications, heat pump service cleaning, etc.) are available or can be contracted for locally on an as-needed basis. The main system consists of two parts - an optical head and electronics rack. The optical head contains the laser transmitter and power supply, transmit/receive switch, optical telescope, tracking angle sensor (intensified CCD camera), detector and power supply, two angular encoders, azimuth and elevation motors, and a protective dome. The optical head mounts directly to the top of a concrete pier which contains the geodetic monument and forms part of the environmental housing for the hardware and servicing personnel. It is equipped with electronic levels for leveling the mount and monitoring its stability.

Degnan, John J.↗

Dry cooling retrofits at existing fossil fuel-fired power plants in a water-stressed region: Tradeoffs in water savings, cost, and capacity shortfalls

This study (completed by US Department of Energy, National Energy Technology Laboratory) investigates the performance, cost, and generating capacity impacts of switching from wet cooling towers to dry cooling systems to reduce consumptive water use at existing fossil fuel-fired power plants in a water-stressed region. Here, retrofit analysis of dry cooling is conducted on a unit-by-unit basis for both coal-fired and gas-fired power plants in several western U.S. states. Based on regional averages, retrofitting dry cooling systems in lieu of wet cooling towers decreases total annual plant water consumption at existing coal- and gas-fired power plants by 93% and 100%, respectively, while increasing the levelized cost of electricity generation by approximately 12% and 18%, respectively. Over the year, the change in monthly net regional generating capacity from dry cooling retrofits exhibits a seasonal pattern, with the largest shortfalls occurring in July. Dry cooling retrofits thus lead to tradeoffs in water savings, cost, and capacity shortfalls, which vary with power plant characteristics. The tradeoffs identified here can inform electric power industry water management plans and decision-making for alternative cooling options in water-stressed regions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Production and testing of the powerboard for ATLAS ITk Strip barrel modules

The upgrade of the ATLAS ITk strips detector for HL-LHC will employ a custom PCB (powerboard) for on-module DC-DC conversion, HV switching, and monitoring. Production of about 14100 of such PCBs with high reliability is a big challenge. In this paper we will present the production procedure and quality control (QC) testing system for the powerboards to be installed on ITk Strip barrel modules. During production, about 150 powerboards will be produced every week. Each powerboard will need to pass QC tests before they are assembled to module. The QC tests include thermal cycling between -35 °C and 40 °C, soak test (continuous running of DC-DC converter at high load at 20 °C), and basic functionality and characterization electrical tests of the low voltage (LV), high voltage (HV), and monitoring functions of the powerboard. A custom QC test system is described, which is based on a reusable PCB (active board) with all testing circuits, a one-time powerboard carrier card, and a Z-turn SoC board which hosts and runs the testing program. The production procedure and QC test system has been tested with 400 powerboards during pre-production, and the system has been proven ready for production with the desired testing program, speed, safety, and cost. Performance and typical failures of powerboards observed during the QC test of pre-production powerboards is also presented.

47 OTHER INSTRUMENTATION↗

A new approach to the design of surface subsystems of polymeric insulators for HV and MV apparatus under AC voltage

The design of high voltage and medium voltage AC and DC standoff insulators, and, in general, of insulation systems where surface and interface properties are predominant factors, is based on specifications and standards that rely upon long-term experiences and lab testing. Surface insulating properties depend on electrical and thermal stresses, besides environmental factors, and the inception of extrinsic ageing phenomena, such as partial discharges, can be already a cause of reduced reliability and premature failure (for organic insulating materials). An innovative approach, based on field simulation, discharge modelling, and partial discharge inception measurements is presented by the authors, which can establish a solid basis to optimise insulation design for any type of supply voltage waveform. This method, the three-leg approach, is applied here to a cable system under AC sinusoidal voltage, but it can work for any type of insulation system, such as bushings, switch gears, transformers, rotating machines, and power electronics boards.

42 ENGINEERING↗

Anomaly Detection, Localization and Classification using Drifting Synchrophasor Data Streams

With ongoing automation and digitization of the electric power system, several Phasor Measurement Units(PMUs) have been deployed for monitoring and control. PMU data can have multiple anomalies, and many of the researchers in the past have concentrated on training machine/deep learning algorithms offline for anomaly detection over PMU data (i.e., not in real time). These machine/deep learning algorithms, when trained offline on a sample rather than a population of the dataset, fail to consider the dynamic behavior of the power grid in real-time, resulting in low accuracy. Considering the dynamic behavior of the power grid (e.g., change in load, generation, distributed energy resources (DERs) switching, network, controls), the definition of data anomalies varies in time and requires online training. A fundamental challenge is to enable online (i.e., real-time) training of machine/deep learning algorithms for anomaly detection over streaming PMU data. While machine/deep learning is often desirable to manage data streams, training a deep learning algorithm over streaming PMU data is nontrivial due to changes in data statistics caused by dynamic streaming data. This paper proposes PMUNET: a novel device-level deep learning-based data-driven approach for anomaly detection, localization, and classification over streaming PMU data, using online learning and multivariate data-drift detection algorithm .Two variants of PMUNET, Dynamic data Change Driven Learning (DCDL) and Continuity Driven Learning (CDL), are proposed and compared. DCDL aims to train the deep learning algorithm whenever the definition of anomaly changes due to the power grid dynamics. On the other hand, CDL continuously trains the deep learning algorithm over the PMU data-stream. The experimental results verify that DCDL outperforms CDL and other efficient anomaly detection methods over multiple events such as faults and load/ generator/capacitor/DERs variations/switching for IEEE 14 and 39 Bus test system as well as real PMU industrial data. The result verifies that DCDL variant of PMUNET improves over existing approach with a gain of 2% - 10% in terms of accuracy, false-positive rate, and false-negative rate.

adversarial deep learning↗

Study of a Solar Sensor for use in Space Vehicle Orientation Control Systems

The solar sensor described herein may be used for a variety of space operations requiring solar orientation. The use of silicon solar cells as the sensing elements provides the sensor with sufficient capability to withstand the hazards of a space environment. A method of arranging the cells in a sensor consists simply of mounting them at a large angle to the base. The use of an opaque shield placed between the cells and perpendicular to the base enhances the small-angle sensitivity while adding slightly to the bulk of the sensor. The difference in illumination of these cells as the result of an oblique incidence of the light rays from the reference source causes an electrical error signal which, when used in a battery-bridge circuit, requires a minimum of electrical processing for use in a space-vehicle orientation control system. An error which could occur after prolonged operation of the sensor is that resulting from asymmetrical aging of opposite cells. This could be periodically corrected with a balance potentiometer. A more routine error in the sensor is that produced by reflected earth radiation. This error may be eliminated over a large portion of the operation time by restricting the field of view and, consequently, the capture capability. A more sophisticated method of eliminating this error is to use separate sensors, for capture and fine pointing, along with a switching device. An experimental model has been constructed and tested to yield an output sensitivity of 1.2 millivolts per second of arc with a load resistance of 1,000 ohms and a reference light source of approximately 1,200 foot-candles delivered at the sensor.

Spencer, Paul R.↗