Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electric load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Aligning Electric Vehicle Customer Charging with Grid Needs

This talk to the National Association of Regulatory Utility Commissioners (NARUC) focuses on "Aligning Electric Vehicle Customer Charging with Grid Needs" to highlight the opportunities associated with managed electric vehicle charging and its value for consumers and the power system. Electric vehicles (EVs) are experiencing a rapid rise in popularity and adoption, and growing EV adoption offers an opportunity to increase electricity demand. With expected widespread EV adoption, supporting charging will require investments in generation, transmission, and distribution systems. Uncoordinated charging of EVs will lead to increased system peak load, possibly exceeding the maximum power that can be supported by distribution systems and generally increasing power system stress. However, vehicles are underutilized assets parked ~96% of the time: managed EV charging can satisfy mobility needs while also supporting the grid. EVs are not a burden for the grid, but a resource: The demand-side flexibility provided by managed EV charging offers significant potential benefits for the grid over multiple timescales and applications., especially for high-renewable systems. Managed charging can support power system planning and operations during normal and extreme conditions, benefitting EV owners and other electricity consumers. Managed charging is shown to consistently provide hundreds of dollars in cost savings per EV each year.

ADVANCED PROPULSION SYSTEMS↗

Rheological and microstructural characterization of aqueous suspensions of carbon black and reduced graphene oxide

Carbon black is often used as a conductivity enhancer in battery electrodes. Reduced graphene oxide is another conducting material, with a high aspect ratio sheet-like morphology, and offers the possibility of generating a conducting network at loadings that are small compared to carbon black. Suspensions of conducting carbon, active materials and binders are typically coated on current collectors during the formation of electrodes. The rheology of these suspensions is an important indicator of the connectivity of particles in the suspension and impacts the electrical conductivity as well as the thickness of the coated layer. In this work, the rheology and microstructures of aqueous suspensions of para-aminobenzoic acid terminated carbon black (CB) with and without reduced graphene oxide (RGO) were investigated. The CB loading varied between 0.05 wt.% -10 wt.%, while the samples containing RGO had an RGO loading of 0.05 wt.%. The pH of the suspension was varied from 7.5 to 3. The carboxyl groups on the CB surface are deprotonated at pH 7.5, making the particles hydrophilic. Protonation of the carboxylate groups at pH 3 makes the particles partially hydrophobic. Suspensions of CB showed Newtonian behavior at all loadings for pH 7.5, and at loadings below 1.5 wt.% for pH 3. They are shear thinning at loadings between 1.5–10 wt.%. Interestingly, the low shear viscosity is non-monotonic with CB loading, rising up to a CB loading of 7.5 wt.%, and then dropping at 10 wt.%. Cryogenic scanning electron microscopy (SEM) showed CB particles forming aggregates at pH 3 for CB loadings greater than 1.5 wt.%. At pH 3, addition of 0.05 wt.% RGO resulted in a viscosity increase for suspensions containing 0.5 wt.% CB, as the RGO formed connections with CB particles that enhanced network formation. Adding RGO had little effect on suspensions that had 1.5 wt.% CB. The combination of SEM imaging and suspension rheology provides insight into the particle connectivity for the carbon-based materials studied here. These insights will be useful in determining coating conditions for slurries used in rechargeable battery electrodes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Energy flexibility of residential buildings: A systematic review of characterization and quantification methods and applications

With building electric demand becoming increasingly dynamic, and a growing percentage of intermittent renewable power generation from solar photovoltaics and wind turbines, the power grid is facing increasing challenge to manage the real time balance between the supply and demand. With advancements in smart sensing and metering, smart appliances, electric vehicles, and energy storage technologies, demand side management of residential buildings can help the grid to improve stability by optimizing flexible loads. This paper reviews recent studies on residential building demand side management, with a focus on characterization and quantification of energy flexibility covering various types of flexible loads, metrics, methods, and applications. The reviewed studies showed four levels of applications: building level (45%), district or community level (29%), system level (19%), and building sector level (7%). Shifting loads is the dominant flexibility type in 60% of applications, followed by shedding (19%), generation (16%), and modulating (6%). Depending on the technology and application scope, flexible operations have a wide range of performance, with peak power reductions of 1%~65%, energy savings up to 60%, operational cost reduction of 1%~48%, and greenhouse gas emission reductions of up to29%. More than half (51%) of the studies employed control strategies to achieve flexibility; among those 72% used optimal controls, while 28% used rule-based controls. About 58% of the studies used mathematical formulation to quantify energy flexibility. Most studies were based on simulation, while less than 15% of the studies had measurements from experiments or field tests. The review reveals research opportunities to address significant gaps in the existing literature: (1) establishing a common definition and performance metrics for energy flexibility of buildings that are technology and application agnostic, (2) developing an ontology to standardize representation of flexibility resources for interoperability, (3) integrating occupant impacts into the quantification and optimization of energy flexibility, and (4) developing requirements and credits of energy flexibility in building energy codes and standards. Findings from the review can inform future research and development of energy flexible buildings which are essential to a reliable and resilient power grid.

Li, H↗

Design and performance assessment of a dual-mode latent thermal storage integrated heat pump across multiple climate zones

The electrification of space cooling and heating systems risks overloading the existing electrical grid during peak hours. Heat pumps integrated with thermal energy storage (HP-TES) offer a promising solution by shifting peak loads to off-peak hours, reducing grid strains. This work presents the design and assessment of a dual-mode HP-TES that uses a single 22°C phase-change material (PCM) as a heat source or sink in heating and cooling modes, respectively. Performance assessment was conducted using Modelica-based transient models, and full-year simulations were conducted across eight US climate zones using typical weather data. Two HP-TES performance metrics: peak energy reduction and recharge energy increases, were defined by comparing HP-TES energy consumption with base HP peak consumptions. Annual heating demand reductions (40–65%) exceeded cooling demand reductions (15–20%) due to the elimination of peak-hour backup heating. Cooling mode recharge energy requirements (0–10%) were reduced in locations with lower summer nighttime temperatures, while heating recharge requirements were lower than the high base-peak energy demand from backup heating. Simplified rapid methods that were 10 7 times faster than annual simulations were developed to predict seasonal cooling and heating energy reductions, and recharge energy requirements, with maximum deviations of ±2.5% and ±3.5% points. These methods enabled rapid parametric studies that identified optimal location-specific PCM temperatures between 22°C and 27°C, highlighting the need to consider both discharge and recharge energy requirements to achieve sustainable, energy-efficient peak load shifting across various climate zones.

25 ENERGY STORAGE↗

Modular Iron–Bipyridine-Based Conjugated Aerogels as Catalysts for Oxygen Reduction Reaction

Aerogels have a large surface area and a porous structure, which make them an attractive catalyst support materials for fuel cells. Modifying the aerogels’ building blocks and introducing catalytic sites into their backbones allow them to function as both catalysts and supports, thereby increasing the density and distribution of catalyst active sites. In this work, we studied conjugated aerogels containing iron–bipyridine catalytic sites for the oxygen reduction reaction. To demonstrate the variation in physical and electrochemical properties of these aerogels, a series of aerogels were synthesized by a Glaser coupling reaction. Iron salt was added to the three-dimensional gel to produce iron–bipyridine complexes and obtain atomically dispersed catalytic sites. The electrocatalytic activity and electrical conductivity of the aerogels were increased after their heat treatment to yield Fe-doped carbon aerogels. The control of metal loadings was accomplished by changing the bipyridine content during the aerogel synthesis, resulting in 0.9–4.1 wt % Fe. In conclusion, the results show a correlation between Fe loading, aerogel structure, and catalytic activity, achieving high performance for the oxygen reduction reaction in both acidic and alkaline media.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A turnkey gaseous helium-cooled superconducting CORC ® dc power cable with integrated current leads

Abstract High-temperature superconducting (HTS) direct current (dc) power cable systems, capable of delivering power exceeding 10 MW while being cooled with cryogenic helium gas, have been developed for applications on naval electric ships, electric aircraft and in data centers. Current injection from room temperature into the superconducting power cable causes by far the greatest heat load to the cryogenic system. Efficient current leads with integrated helium gas heat exchangers were developed to inject a current exceeding 1 kA from room temperature into a superconducting Conductor on Round Core (CORC ® ) power cable, without the need for liquid nitrogen pre-cooling. A 2 m long single-pole CORC ® power cable system that included current leads was cooled using a Stirling cryocooler with a closed-loop helium gas circulation system. The turnkey power cable system allowed cool down from room temperature to its operating temperature of 60 K–70 K within 5 h, after which continuous operation at 1.2 kA was demonstrated. The successful development and demonstration of a CORC ® power cable with current leads containing integrated helium gas heat exchangers enables widespread implementation of HTS MW-class, high current density superconducting dc power cables in many applications with constrained space that require a power dense solution.

Physics↗

DC-Ripple-Energy Adaptive-Minimization (DREAM) Modulation Scheme for a High Power Density Inverter

The DC bus capacitor is one of the major power-density and reliability hurdles of electric drive systems. It is hard to shrink because it is constrained by the DC bus RMS ripple current, which is only load dependent. A dual-inverter based segmented drive can reduce the ripple current by ~50% compared to a non-segmented case. This paper analyzes the origin of this ripple current and points out the path for minimization. An optimal DC-ripple-energy adaptive-minimization (DREAM) modulation method is proposed to further reduce the ripple current. It is observed in experimental results that the proposed method can achieve additional 38% reduction over the traditional segmented drive system.

Xue, Lincoln↗

Mechanical Analysis of Carbon Fiber Retaining Sleeve for A High-speed Outer Rotor SPM Electric Motor Design

Outer rotor motors can be designed with a larger airgap diameter than inner rotor motors for the same overall diameter and therefore provide higher torque which makes them ideal for high torque space constrained applications. This advantage fits well with the increasing demand of high-speed electric machines in many applications due to their inherent high-power density. However, increasing the motor speed results in significant centrifugal loads for the outer rotor motor design. Layers of carbon fiber sleeve winding on the rotor outer surface is necessary to guarantee its structural integrity without introducing too much weight on the motor itself. In this paper, we studied the mechanical stress of a carbon fiber retaining sleeve in a surface permanent magnet outer rotor motor that spins up to 20,000 RPM. Analytical results from finite element method (FEM) confirmed that the maximum stress experienced by the carbon fiber sleeve was under the material’s yield strength. The proposed sleeve will allow this outer rotor motor to operate at high speeds.

Lin, Lianshan↗

Crack Propagation Modeling of a High-Speed Outer Rotor Motor

This study aims to investigate the propagation of initial cracks in electric motors and their rate of spread through the rotor structure under various operating conditions. Traction motors are subjected to high centrifugal load owing to their speed and rapid acceleration and deceleration. In the manufacturing process, some initial imperfections or cracks in the rotor components are likely to occur. Under the influence of loading, these cracks will grow, and factors such as loading frequency, material strength, and location of material voids will affect this threshold speed. In the current study, a fracture mechanics–based approach has been used to investigate the crack growth rate for a 100 kW outer rotor motor with a rated speed of 6,000 rpm and a peak speed of 20,000 rpm for an integrated drive application.

Barua, Himel↗

Model-Free Control of Grid-Interactive Efficient Buildings Under Communication Time Delays

Grid-interactive efficient buildings (GEBs) have recently been used to enhance the reliability and stability of the electric grid through demand response (DR) programs. However, most existing DR control strategies require accurate modeling of the various building thermostatically controlled loads (TCLs) and are computationally expensive. To address these challenges, a model-free control (MFC)-based strategy has recently been introduced for coordinating and controlling GEBs. MFC is a data-enabled control strategy that is computationally efficient and does not require the analytical models of the various building equipment. In this paper, we numerically investigate the impact of communication time delays on the performance of MFC in maintaining the TCLs' temperatures within the desired comfort levels while meeting the assigned power allocation constraint.

Telsang, Bhagyashri [University of Tennessee, Knox↗

TEAMER: FOSWEC Mooring Modeling and Analysis, Post Access Report and Data

Floating oscillating surge wave energy converters (FOSWECs) offer several advantages over bottom-hinged oscillating surge wave energy converters, including large wave potential at deep-water sites with fewer permitting and environmental concerns outside territorial waters. As a team, Stevens Institute of Technology, Virginia Tech and Resolute Marine Energy are designing a 100 kW FOSWEC with DOE support (2020-2021) for the PacWave test site "PacWave". The proposed FOSWEC consists of a floating platform, two pivoting flaps, and an innovative power-take-off (PTO). The distance between the two flaps is around half the typical wavelength, resulting in out-of-phase motion and a reduction in motion of the frame and mooring loads. The overall goal of the project is to design, build, deploy and analyze a 1:2 scale (100-kW annual averaged electrical power output) device with reduced levelized cost of energy (LCOE) and peak-to-average power ratio, through the co-design and control of the PTO, WEC, and floating platform. This submission includes a Post Access Report and data for the project of Mooring Modeling and Analysis for Floating Oscillating Surge Wave Energy Converter that Powers Marine Aquaculture of RFTS2 (request for technical support). The data are used to generate all figures in the Post Access Report. Project was a collaboration between Virginia Tech and the National Renewable Energy Lab, with funding from TEAMER.

16 TIDAL AND WAVE POWER↗

ENG 572 Final Report

Thermo-electric coolers (TECs) provide an essential function in many high-powered applications by diverting heat away from a temperature-sensitive load. This summer I have worked with Sandia National Laboratories in exploring the failure mechanisms behind said devices. I have been tasked with determining a plan of action for two TECs manufactured by two different companies labeled A and B respectively. Prior to my involvement in the project, the former has displayed failures during normal operation within its packaging. The latter was subsequently chosen to resolve these issues. Thermal cycling between the extreme expected operating temperatures (-40°C to 80°C) was applied to 5 unmounted TECAs over a period of 5 hours with 1-hour soaks at each extreme. The unmounted TECBs are currently undergoing the same process, and the task is expected to be completed over the next few weeks. The results of the TECA characterization have indicated no failure has occurred, which indicates that failure will need to be induced through either higher temperature extremes or additional mechanical stress.

47 OTHER INSTRUMENTATION↗

Designing and Operating Resilient Electric Distribution Grids [Slides]

In the past, electricity was produced by power plants on the transmission system and distributed to customers through substations. Now, distributed energy resources and dynamic loads are penetrating distribution grids, with their own energy production, resilience, and reliability challenges separate from the traditional model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An assessment of the global cooling supply chain and implications for critical minerals

The global room air conditioner (AC) industry has undergone rapid growth, and the U.S. and India now face new supply chain risks due to China’s dominant role in manufacturing and driving demand. As India’s room AC market and related electricity consumption increases with continued economic development, it faces dual challenges of supply chain vulnerabilities and power grid blackouts from higher peak loads. To mitigate supply chain vulnerabilities for high-efficiency cooling equipment and critical mineral inputs to AC components, there is an increasing need to diversify the supply chain and address energy security and peak load risks to both the U.S. and India. This report assesses the potential for diversifying supply chains and scaling up manufacturing of highly efficient cooling equipment technologies and related critical mineral inputs in the U.S. and India. Successful cooperation on these technologies will enable the U.S., India, and their Quadrilateral Security Dialogue (Quad) partners to diversify AC supply chains while meeting India’s large and growing demand for efficient cooling. In the similarly concentrated supply chain for critical minerals, the U.S. and India can work with Japan and Australia to leverage each country’s strengths in diversifying mining, processing, and refining while pursuing alternatives to materials with high supply chain risks and supporting increased recycling and circular economy approaches.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Fast, Controllable, and Modular Solid-State Circuit Breaker Design for Battery Management Systems

Electric power grid is experiencing a growing number of distributed and inertia-free generation resources. To facilitate the growing generation and load demands, and ensure stable operation, energy storage systems, especially behind-themeter-storage (BTMS), have emerged as a potential candidate. BTMS plays a vital role in the grid storage sector and supports high power charging for EVs. However, the potential of thermal runaway and associated safety concerns in the batteries can hamper their widespread adoption. In this work, we provide a solution for a fast and controllable discharge of a cell that was identified as a stressful/faulty, in the battery pack, and fast circuit breaking leveraging the Solid-State Circuit Breaker (SSCB) technology which provides active control over the cell connection as opposed to conventional passive solutions. Testing on the simulation platform successfully validated the concept, demonstrating its efficacy. Controlled discharge testing with 20Ah LiFePO4 Lithium Iron Phosphate (LFP) cells from 1C-10C current rate on the hardware prototype corroborated simulation results, demonstrating design feasibility and providing essential data for its performance and thermal characteristics, while also revealing limitations that inform areas for further optimization.

33 ADVANCED PROPULSION SYSTEMS↗

Towards Energy-Positive Buildings through a Quality-Matched Energy Flow Strategy

Current strategies for net-zero buildings favor envelopes with minimized aperture ratios and limiting of solar gains through reduced glazing transmittance and emissivity. This load-reduction approach precludes strategies that maximize on-site collection of solar energy, which could increase opportunities for net-zero electricity projects. To better leverage solar resources, a whole-building strategy is proposed, referred to as “Quality-Matched Energy Flows” (or Q-MEF): capturing, transforming, buffering, and transferring irradiance on a building’s envelope—and energy derived from it—into distributed end-uses. A mid-scale commercial building was modeled in three climates with a novel Building-Integrated, Transparent, Concentrating Photovoltaic and Thermal fenestration technology (BITCoPT), thermal storage and circulation at three temperature ranges, adsorption chillers, and auxiliary heat pumps. BITCoPT generated electricity and collected thermal energy at high efficiencies while transmitting diffuse light and mitigating excess gains and illuminance. The balance of systems satisfied cooling and heating demands. Relative to baselines with similar glazing ratios, net electricity use decreased 71% in a continental climate and 100% or more in hot-arid and subtropical-moderate climates. Total EUI decreased 35%, 83%, and 52%, and peak purchased electrical demands decreased up to 6%, 32%, and 20%, respectively (with no provisions for on-site electrical storage). Decreases in utility services costs were also noted. These results suggest that with further development of electrification the Q-MEF strategy could contribute to energy-positive behavior for projects with similar typology and climate profiles.

54 ENVIRONMENTAL SCIENCES↗

The Potential of Hydrogen in a Decarbonized Future

Green hydrogen has become an interesting opportunity for utilities especially while considering a decarbonized future. This presentation will discuss how producing green hydrogen can benefit the grid when generation exceeds load and possible applications and markets for green hydrogen including injection into the natural gas system and as a fuel for dispatchable electricity generation during peak times. Technology and market status and challenges will also be identified.

decarbonization↗

A hybrid method to evaluate the life cycle climate performance of heat pumps

Heat pumps have a significant impact on the climate, and numerous studies exist discussing the environmental impact of heat pumps quantitatively. Life Cycle Climate Performance (LCCP) is a widely accepted metric and can evaluate the carbon footprint of heat pumps from cradle to grave. LCCP calculation typically requires inputs like annual energy consumption, the material used, refrigerant type, and charge level, which are usually the intermediate or final results from heat pump simulation tools. Thus, a platform linking the heat pump simulation software, local weather conditions, and LCCP evaluation tool can simplify the heat pump design process, especially for complicated systems. This paper presents an LCCP evaluation tool accessing the outputs from the DOE Heat Pump Design Model and the building loads and temperature bin data from AHRI standard 210/240. As for case studies, this paper investigates the LCCP values and life cycle electricity costs (LCEC) of a given cooling-based heat pump with R410A in five typical US cities. In conclusion, this cooling-based heat pump has the highest LCCP value at Chicago and lowest LCCP value at Seattle. In contrast, the heat pump has the highest LCEC at Seattle and the lowest LCEC at Miami. As a future work, a more comprehensive carbon emission and cost analysis of heat pump systems will be conducted through all major cities around the world.

Shen, Bo↗