Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diode effects”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Photovoltaic Hydrogen Sensor

Photovoltaic device senses hydrogen developed to test degradation of diodes with platinum flash gates on backs. Sensing element is p/n junction rather than conventional Schottky barrier or metal oxide/silicon field-effect transistor. Hydrogen-indicating electrical signal modulated optically rather than electrically. Layered structure of hydrogen detector and principle of operation resemble silicon solar photovoltaic cell. Hydrogen detector responds to hydrogen in atmosphere within minutes and recovers quickly when hydrogen removed.

Daud, Taher↗

Aging behavior of Au-based ohmic contacts to GaAs

Gold based alloys, commonly used as ohmic contacts for solar cells, are known to react readily with GaAs. It is shown that the contact interaction with the underlying GaAs can continue even at room temperature upon aging, altering both the electrical characteristics of the contacts and the nearby pn junction. Au-Ge-Ni as-deposited (no heat-treatment) contacts made to thin emitter (0.15 microns) GaAs diodes have shown severe shunting of the pn junction upon aging for several months at room temperature. The heat-treated contacts, despite showing degradation in contact resistance, did not affect the underlying pn junction. Au-Zn-Au contacts to p-GaAs emitter (0.2 microns) diodes, however, showed slight improvement in contact resistance upon 200 C isothermal annealing for several months, without degrading the pn junction. The effect of aging on electrical characteristics of the as-deposited and heat-treated contacts and the nearby pn junction, as well as on the surface morphology of the contacts are presented.

Fatemi, Navid S.↗

Dc-To-Dc Converter Uses Reverse Conduction Of MOSFET's

In modified high-power, phase-controlled, full-bridge, pulse-width-modulated dc-to-dc converters, switching devices power metal oxide/semiconductor field-effect transistors (MOSFET's). Decreases dissipation of power during switching by eliminating approximately 0.7-V forward voltage drop in anti-parallel diodes. Energy-conversion efficiency increased.

Gruber, Robert P.↗

HgCdTe Photoconductive Mixers for 2-8 THz

Heterodyne spectroscopy has been taken to wavelengths as short as 63 micrometers with Schottky-diode mixers. Schottkys, however, are relatively insensitive compared to superconducting mixers such as the hot-electron microbolometer (HEB), which has an effective quantum efficiency of 3% at 120 micrometers (2.5 THz). Although HEB sensitivities are bound to improve, there will always be losses associated with antenna coupling of radiation into sub-micron size devices. Another approach to far infrared (FIR) mixer design is to use a photoconductive device which can be made much larger than a wavelength, and thus act as its own antenna. For example, HgCdTe photodiodes have been used as mixers in the lambda = 10 micrometers band for over 25 years, with sensitivities now only a factor of 2 from the quantum-noise-limit. HgCdTe can also be applied at FIR wavelengths, but surprisingly little work has been done to date. The exception is the pioneering work of Spears and Kostiuk and Spears, who developed HgCdTe photomixers for the 20-120 micrometer region. The spectral versatility of the HgCdTe alloy is well recognized for wavelengths as long as 8-20 micrometers. What is not so recognized, however, is that theoretically there is no long wavelength limit for appropriately composited HgCdTe. Although Spears successfully demonstrated a photoconductive response from HgCdTe at 120 micrometers, this initial effort was apparently never followed up, in part because of the difficulty of controlling the HgCdTe alloy composition with liquid-phase-epitaxy (LPE) techniques. With the availability of precise molecular-beam-epitaxy (MBE) since the early 1990's, it is now appropriate to reconsider HgCdTe for detector applications longward of lambda = 20 micrometers. We recently initiated an effort to fabricate detectors and mixers using II-VI materials for FIR wavelengths. Of particular interest are device structures called superlattices, which offer a number of advantages for high sensitivity direct detectors and very long wavelength heterodyne mixers.

Betz, A. L.↗

Analysis of Carbon Nanotube Metal-Semiconductor Diode Device

We study recently reported drain current Id-drain voltage Vd characteristics of a carbon nanotube metal semiconductor diode device with the gate voltage Vg applied to modulate the carrier density in the nanotube. The diode was kink-shaped at the metal-semiconductor interface. It was shown that (1) larger negative Vg blocked Id more effectively in the negative Vd region, resulting in the rectifying Id-Vd characteristics, and that (2) positive Vg allowed Id in the both Vd polarities, resulting in the non-rectifying characteristics. The negative Vd was the Schottky reverse direction, judging from the negligible Id behavior for a wide region of -4 V less than Vd less than 0 V, with Vg = -4 V. Such negative Vg would attract positive charges from the metallic electrodes (charge reservoir) to the nanotube and lower the nanotube Fermi energy (EF). With larger negative Vg, the experiment showed that the Schottky forward direction (Vd greater than 0) had a smaller turn-on voltage and the Schottky reverse direction (Vd less than 0) was more resistant to the tunneling breakdown. Therefore, the majority carriers in the transport would be electrons since they can see a lower tunneling barrier (shallower built-in potential) in the forward direction when EF is lowered, and a thicker tunneling barrier (Schottky barrier) in the reverse direction due to the reduction in the electron density when EF is lowered.

Yamada, Toshishige↗

AlGaAs/GaAs laser diode bars (λ = 808 nm) with improved thermal stability

Two series of AlGaAs/GaAs laser heterostructures have been grown by metal-organic vapour phase epitaxy, and 808-nm laser diode bars fabricated from the heterostructures have been investigated. The heterostructures differed in waveguide thickness and quantum well depth. It is shown that increasing the barrier height for charge carriers in the active region has an advantageous effect on the output parameters of the laser sources in the case of the heterostructures with a narrow symmetric waveguide: the slope of their power – current characteristics increased from 0.9 to 1.05 W A{sup -1}. Thus, the configuration with a narrow waveguide and deep quantum well is better suited for high-power laser diode bars under hindered heat removal conditions. (lasers)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tooth Whitening And Temperature Rise With Two Bleaching Activation Methods

To measure the tooth whitening and the surface and Intrapulpal temperature increase in vitro on freshly extracted upper human central incisors after chemical, Zoom AP light and diode laser activated bleaching. Thirty caries-free upper human incisors were selected. Teeth were divided into three equal groups according to the methods of activation of the bleaching agent (n = 10). A whitening gel containing hydrogen peroxide was applied to the buccal surface of all teeth. Group I was bleached using chemically activated hydrogen peroxide gel, for three applications of 15 min each. Group II was bleached with high intensity advanced power Zoom activation light (Zoom AP), for three applications of 15 min each. Group III was bleached with diode laser activation technique, where the teeth were irradiated with 2 Watt diode laser for three applications of 30 sec each. The whitening degree was assessed using an image analysis system, while temperature rise was recorded using a thermocouple on the external tooth surface and Intrapulpal. The degree of whitening increased significantly in all groups. However, the percentage of whitening was not statistically significantly different between the three groups. In addition, group II showed statistically significant higher mean rise in both surface and pulp temperatures than group I and group III. Chemical bleaching produces the same whitening effect as Zoom AP light and laser, with no surface or pulpal temperature rise. Laser application is faster and produces less surface and pulp temperature increase than Zoom AP light. Diode laser used to activate bleaching gels is not considered dangerous to the vitality of dental pulp using power settings of 2 W.

36 MATERIALS SCIENCE↗

Compositionally Graded Alloy Quantum Dot Phosphors for Solid State Lighting. Final Report

To push the boundaries of efficiency and cost in solid state lighting (SSL), narrow band red emitting down conversion phosphors must be improved. These materials are critical to both the color rendering ability and optical output of phosphor converted light emitting diodes (LEDs). Improvements in these performance parameters will have a significant impact on the adoption of SSL in retail, office, and home lighting applications. Quantum Dots (QDs) are widely acknowledged as a cost-effective front-runner among developing downconverting technologies because they emit narrow band luminescence that is tunable across the visible spectrum. Current syntheses of quantum dots, however, utilize expensive and toxic reagents and often involve several time-intensive purification steps. To address this, we have introduced a novel, cost-effective synthetic scheme, whereby the final quantum dot structures can be accessed with fewer synthetic steps using a library of inexpensive, easily-synthesized precursors. With the help of automated high throughput synthesis robotics, Columbia, LBNL, and OSRAM have optimized red and amber CdS/CdSe/CdS QD architectures for SSL. QDs with improved shelling layers have been identified that meet the industry state of the art performance on chip under high humidity accelerated aging tests. This is remarkable considering the time frame of this project compared to the time and resources allocated for the development of the industrial standard. Furthermore, although particle stability to optical charging is often stressed in improving QLED performance, we have identified effective ZnS particle over-coating as the most important factor determining particle survivability and device performance in down-converting LEDs.

36 MATERIALS SCIENCE↗

Discrete space charge affected field emission: Flat and hemisphere emitters

Models of space-charge affected thermal-field emission from protrusions, able to incorporate the effects of both surface roughness and elongated field emitter structures in beam optics codes, are desirable but difficult. The models proposed here treat the meso-scale diode region separate from the micro-scale regions characteristic of the emission sites. The consequences of discrete emission events are given for both one-dimensional (sheets of charge) and three dimensional (rings of charge) models: in the former, results converge to steady state conditions found by theory (e.g., Rokhlenko et al. [J. Appl. Phys. 107, 014904 (2010)]) but show oscillatory structure as they do. Surface roughness or geometric features are handled using a ring of charge model, from which the image charges are found and used to modify the apex field and emitted current. The roughness model is shown to have additional constraints related to the discrete nature of electron charge. The ability of a unit cell model to treat field emitter structures and incorporate surface roughness effects inside a beam optics code is assessed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On the uncertainty of the Auger recombination coefficient extracted from InGaN/GaN light-emitting diode efficiency droop measurements

III-nitride light-emitting diodes (LEDs) suffer from a severe efficiency reduction with increasing injection current (droop). Auger recombination is often seen as primary cause of this droop phenomenon. The corresponding Auger recombination coefficient C is typically obtained from efficiency measurements using mathematical models. However, C coefficients reported for InGaN active layers vary over two orders of magnitude. We here investigate this uncertainty and apply successively more accurate models to the same efficiency measurement, thereby revealing the strong sensitivity of the Auger coefficient to quantum well properties such as electron-hole ratio, electric field, and hot carrier escape.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Deposition-Dependent Coverage and Performance of Phosphonic Acid Interface Modifiers in Halide Perovskite Optoelectronics

In this work, we study the effect of various deposition methods for phosphonic acid interface modifiers commonly pursued as self-assembled monolayers in high-performance metal halide perovskite photovoltaics and light-emitting diodes. We compare the deposition of (2-(3,6-diiodo-9H-carbazol-9-yl)ethyl)phosphonic acid onto indium tin oxide (ITO) bottom contacts by varying three parameters: the method of deposition, specifically spin coating or prolonged dip coating; ITO surface treatment via HCl/FeCl3 etching; and use in combination with a second modifier, 1,6-hexylenediphosphonic acid. We demonstrate that varying these modification protocols can impact time-resolved photoluminescence carrier lifetimes and quasi-Fermi level splitting of perovskite films deposited onto the phosphonic acid-modified ITO. Ultraviolet photoelectron spectroscopy shows an increase in the effective work function after phosphonic acid modification and clear evidence for photoemission from carbazole functional groups at the ITO surface. We used X-ray photoelectron spectroscopy to probe differences in phosphonic acid coverage on the metal oxide contact and show that perovskite samples grown on ITO with the highest phosphonic acid coverage exhibit the longest carrier lifetimes. Finally, we establish that device performance follows these same trends. These results indicate that the reactivity, heterogeneity, and composition of the bottom contact help to control recombination rates and therefore power conversion efficiencies. ITO etching, prolonged deposition times for phosphonic acids via dip coating, and the use of a secondary, more hydrophilic bisphosphonic acid all contribute to improvements in surface coverage, carrier lifetime, and device efficiency. Furthermore, these improvements each have a positive impact, and we achieve the best results when all three strategies are implemented.

contact engineering↗

A study of the effect of fast neutrons and electrons on white and blue LEDs

Current-voltage and light-current characteristics of light-emitting InGaN/GaN heterostructures and blue and white light-emitting diodes before and after irradiation with fast neutrons and electrons are analyzed. A generalized model of a light-emitting heterostructure, with an optically active region with one or several quantum wells in the compensated layer, is suggested. The constants of nonradiative lifetime degradation of blue and white light-emitting diodes under irradiation are estimated.

36 MATERIALS SCIENCE↗

Detector to detector corrections: A comprehensive experimental study of detector specific correction factors for beam output measurements for small radiotherapy beams

Purpose: The aim of the present study is to provide a comprehensive set of detector specific correction factors for beam output measurements for small beams, for a wide range of real time and passive detectors. The detector specific correction factors determined in this study may be potentially useful as a reference data set for small beam dosimetry measurements. Methods: Dose response of passive and real time detectors was investigated for small field sizes shaped with a micromultileaf collimator ranging from 0.6 × 0.6 cm{sup 2} to 4.2 × 4.2 cm{sup 2} and the measurements were extended to larger fields of up to 10 × 10 cm{sup 2}. Measurements were performed at 5 cm depth, in a 6 MV photon beam. Detectors used included alanine, thermoluminescent dosimeters (TLDs), stereotactic diode, electron diode, photon diode, radiophotoluminescent dosimeters (RPLDs), radioluminescence detector based on carbon-doped aluminium oxide (Al{sub 2}O{sub 3}:C), organic plastic scintillators, diamond detectors, liquid filled ion chamber, and a range of small volume air filled ionization chambers (volumes ranging from 0.002 cm{sup 3} to 0.3 cm{sup 3}). All detector measurements were corrected for volume averaging effect and compared with dose ratios determined from alanine to derive a detector correction factors that account for beam perturbation related to nonwater equivalence of the detector materials. Results: For the detectors used in this study, volume averaging corrections ranged from unity for the smallest detectors such as the diodes, 1.148 for the 0.14 cm{sup 3} air filled ionization chamber and were as high as 1.924 for the 0.3 cm{sup 3} ionization chamber. After applying volume averaging corrections, the detector readings were consistent among themselves and with alanine measurements for several small detectors but they differed for larger detectors, in particular for some small ionization chambers with volumes larger than 0.1 cm{sup 3}. Conclusions: The results demonstrate how important it is for the appropriate corrections to be applied to give consistent and accurate measurements for a range of detectors in small beam geometry. The results further demonstrate that depending on the choice of detectors, there is a potential for large errors when effects such as volume averaging, perturbation and differences in material properties of detectors are not taken into account. As the commissioning of small fields for clinical treatment has to rely on accurate dose measurements, the authors recommend the use of detectors that require relatively little correction, such as unshielded diodes, diamond detectors or microchambers, and solid state detectors such as alanine, TLD, Al{sub 2}O{sub 3}:C, or scintillators.

07 ISOTOPE AND RADIATION SOURCES↗

SU-C-BRC-04: Efficient Dose Calculation Algorithm for FFF IMRT with a Simplified Bivariate Gaussian Source Model

Purpose: To develop an efficient and accurate independent dose calculation algorithm with a simplified analytical source model for the quality assurance and safe delivery of Flattening Filter Free (FFF)-IMRT on an Elekta Versa HD. Methods: The source model consisted of a point source and a 2D bivariate Gaussian source, respectively modeling the primary photons and the combined effect of head scatter, monitor chamber backscatter and collimator exchange effect. The in-air fluence was firstly calculated by back-projecting the edges of beam defining devices onto the source plane and integrating the visible source distribution. The effect of the rounded MLC leaf end, tongue-and-groove and interleaf transmission was taken into account in the back-projection. The in-air fluence was then modified with a fourth degree polynomial modeling the cone-shaped dose distribution of FFF beams. Planar dose distribution was obtained by convolving the in-air fluence with a dose deposition kernel (DDK) consisting of the sum of three 2D Gaussian functions. The parameters of the source model and the DDK were commissioned using measured in-air output factors (Sc) and cross beam profiles, respectively. A novel method was used to eliminate the volume averaging effect of ion chambers in determining the DDK. Planar dose distributions of five head-and-neck FFF-IMRT plans were calculated and compared against measurements performed with a 2D diode array (MapCHECK™) to validate the accuracy of the algorithm. Results: The proposed source model predicted Sc for both 6MV and 10MV with an accuracy better than 0.1%. With a stringent gamma criterion (2%/2mm/local difference), the passing rate of the FFF-IMRT dose calculation was 97.2±2.6%. Conclusion: The removal of the flattening filter represents a simplification of the head structure which allows the use of a simpler source model for very accurate dose calculation. The proposed algorithm offers an effective way to ensure the safe delivery of FFF-IMRT.

60 APPLIED LIFE SCIENCES↗

On the importance of AlGaN electron blocking layer design for GaN-based light-emitting diodes

There has been confusion regarding the usefulness of AlGaN electron blocking layer (EBL) in GaN-based light-emitting diodes (LEDs) with some published experimental data indicating that the LEDs without EBL performed better than those with it. InGaN/GaN LEDs have been investigated numerically to analyze its actual effect in these devices. Simulation results show that hole blocking effect of EBL mainly determines the effectiveness of using it which is more sensitive to its Al composition, band offset ratio, and polarization charges. It is found that the choice of Al composition is critical for EBL to improve the optical performance of GaN-based LEDs.

36 MATERIALS SCIENCE↗

Enhancement of hole injection and electroluminescence by ordered Ag nanodot array on indium tin oxide anode in organic light emitting diode

We report the enhancement of hole injection and electroluminescence (EL) in an organic light emitting diode (OLED) with an ordered Ag nanodot array on indium-tin-oxide (ITO) anode. Until now, most researches have focused on the improved performance of OLEDs by plasmonic effects of metal nanoparticles due to the difficulty in fabricating metal nanodot arrays. A well-ordered Ag nanodot array is fabricated on the ITO anode of OLED using the nanoporous alumina as an evaporation mask. The OLED device with Ag nanodot arrays on the ITO anode shows higher current density and EL enhancement than the one without any nano-structure. These results suggest that the Ag nanodot array with the plasmonic effect has potential as one of attractive approaches to enhance the hole injection and EL in the application of the OLEDs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-T-628: Effect of Dose Rate and Leakage Correction for Dosimetric Leaf Gap Measurement

Purpose: To study the dose rate response of Mapcheck and quantify/correct dose rate/leakage effect on IMRT QA. Evaluate the dose rate/leakage effect on dosimetric leaf gap (DLG) measurement. Methods: Varian Truebeam Linac with HD120 MLC was used for all measurement, it is capable to adjust dose rate from 600MU/min to 5MU/min. Fluke Advanced Therapy Doisemter and PTW 30013 Farmer chamber for chamber measurement; SunNuclear Mapcheck2 with 5cm total buildup for diode measurement. DLG was measured with both chamber and diode.Diode response was measured by varies dose rate, while fixed mapcheck setup and total MU. MLC Leakage was measured with both chamber and diode. Mapcheck measurement was saved as movie file (mcm file), which include measurement updated every 50mSec. The difference between intervals can be converted to dose and dose rate and leakage response correction can be applied to them. Results: DLG measurement results with chamber and diode were showed as follows, the DLG value is 0.36 vs. 0.24mm respectively. Diode dose rate response drops from 100% at 600MU/min to 95.5% at 5MU/min as follows. MLC Leakage measured with diode is 1.021%, which is 9% smaller than 1.112% from chamber measurement. By apply the dose rate and leakage correction, the residue error reduced 2/3. Conclusions: Diode has lower response at lower dose rate, as low as 4.5% for 5MU/min; diode has lower energy response for low energy too, 5% lower for Co-60 than 6MV. It partially explains the leakage difference of 9% between chamber and diode. Lower DLG with diode is because of the lower response at narrower gap, in Eclipse however DLG need to increase to makeup lower response, which is over correction for chamber though. Correction can reduce error by 2/3, the rest 1/3 can be corrected by scatter effect, which is under study.

07 ISOTOPE AND RADIATION SOURCES↗