Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “destructive techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Advanced non-destructive assessment technology to determine the aging of silicon containing materials for generation IV nuclear reactors

To create an in-situ, real-time method of monitoring neutron damage within a nuclear reactor core, irradiated silicon carbide samples are examined to correlate measurable variations in the material properties with neutron fluence levels experienced by the silicon carbide (SiC) during the irradiation process. The reaction by which phosphorus doping via thermal neutrons occurs in the silicon carbide samples is known to increase electron carrier density. A number of techniques are used to probe the properties of the SiC, including ultrasonic and Hall coefficient measurements, as well as high frequency impedance analysis. Gamma spectroscopy is also used to examine residual radioactivity resulting from irradiation activation of elements in the samples. Hall coefficient measurements produce the expected trend of increasing carrier concentration with higher fluence levels, while high frequency impedance analysis shows an increase in sample impedance with increasing fluence.

36 MATERIALS SCIENCE↗

Neutron and X-Ray Studies of Advanced Materials V: CENTENNIAL Symposium

In 2012 the diffraction community will celebrate 100 years since the prediction of X-ray diffraction by M. Laue, and following his suggestion the first beautiful diffraction experiment by W. Friedrich and P. Knipping. The significance of techniques based on the analysis of the diffraction of X-rays, neutrons, electrons and Mossbauer photons discovered later, has continued to increase in the past 100 years. The aim of this symposium is to provide a forum for discussion of using state-of-the-art neutron and X-ray scattering techniques for probing advanced materials. These techniques have been widely used to characterize materials structures across all length scales, from atomic to nano, meso, and macroscopic scales. With the development of sample environments, in-situ experiments, e.g., at temperatures and applied mechanical load, are becoming routine. The development of ultra-brilliant third-generation synchrotron X-ray sources, together with advances in X-ray optics, has created intense X-ray microbeams, which provide the best opportunities for in-depth understanding of mechanical behavior in a broad spectrum of materials. Important applications include ultra-sensitive elemental detection by X-ray fluorescence/absorption and microdiffraction to identify phase and strain with submicrometer spatial resolution. X-ray microdiffraction is a particularly exciting application compared with alternative probes of crystalline structure, orientation and strain. X-ray microdiffraction is non-destructive with good strain resolution, competitive or superior spatial resolution in thick samples, and with the ability to probe below the sample surface. Advances in neutron sources and instrumentation also bring new opportunities in neutron scattering research. In addition to characterizing the structures, neutrons are also a great tool for elucidating the dynamics of materials. Because neutrons are highly penetrating, neutrons have been used to map stress in engineering systems. Neutrons have also played a vital role in our understanding of the magnetism and magnetic properties. Specialized instruments have been built to gain physical insights of the fundamental mechanisms governing phase transformation and mechanical behaviors of materials. The application of those techniques, in combination with theoretical simulations and numerical modeling, will lead to major breakthroughs in materials science in the foreseeable future that will contribute to the development of materials technology and industrial innovation.

36 MATERIALS SCIENCE↗

Comparison of SOFC Cathode Microstructure Quantified using X-ray Nanotomography and Focused Ioni Beam-scanning Electron Microscopy

X-ray nanotomography and focused ion beam scanning electron microscopy (FIB-SEM) have been applied to investigate the complex 3D microstructure of solid oxide fuel cell (SOFC) electrodes at spatial resolutions of 45 nm and below. The application of near edge differential absorption for x-ray nanotomography and energy selected backscatter detection for FIB-SEM enable elemental mapping within the microstructure. Using these methods, non-destructive 3D x-ray imaging and FIB-SEM serial sectioning have been applied to compare three-dimensional elemental mapping of the LSM, YSZ, and pore phases in the SOFC cathode microstructure. The microstructural characterization of an SOFC cathode is reported based on these measurements. The results presented demonstrate the viability of x-ray nanotomography as a quantitative characterization technique and provide key insights into the SOFC cathode microstructure.

30 DIRECT ENERGY CONVERSION↗

Quantum Phase Transitions and Continuous Observation of Spinor Dynamics in an Antiferromagnetic Condensate

Condensates of spin-1 sodium display rich spin dynamics due to the antiferromagnetic nature of the interactions in this system. We use Faraday rotation spectroscopy to make a continuous and minimally destructive measurement of the dynamics over multiple spin oscillations on a single evolving condensate. This method provides a sharp signature to locate a magnetically tuned separatrix in phase space which depends on the net magnetization. We also observe a phase transition from a two- to a three-component condensate at a low but finite temperature using a Stern-Gerlach imaging technique. This transition should be preserved as a zero-temperature quantum phase transition.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

3013 Baseline Inner Container Report: Description, Imaging, and Analysis

This report presents consolidated findings from three microscopy studies of baseline Bagless Transfer Containers (BTCs), which are the inner containers used in DOE Standard 3013-compliant plutonium storage packages. The studies were conducted by Los Alamos National Laboratory (LANL), Savannah River National Laboratory (SRNL), and DNV, a subcontractor specializing in corrosion science. The baseline BTCs examined had not been exposed to corrosive environments, serving as control samples for comparison with destructively examined (DE) containers. Additionally, the Background section provides an overview of the BTC design, including manufacturing methods, material properties, and container configurations that may influence corrosion behavior. The primary objective of the LANL and SRNL studies was to establish reference characteristics of BTCs to distinguish manufacturing artifacts from corrosion-induced features observed in DE containers. Both laboratories used advanced microscopy techniques, including Wide Area Microscopy (WAMS), Laser Confocal Microscopy (LCM), Scanning Electron Microscopy (SEM), and Focused Ion Beam (FIB), to reveal that most surface anomalies were shallow and attributable to flow-forming processes, not corrosion. Subsurface impurities, identified as non-metallic inclusions, were also observed. DNV’s investigation focused on characterizing the mechanical and chemical properties of the BTC material to support crack growth modeling. Their findings indicate higher hardness and strength but reduced ductility—consistent with flow-formed 304L stainless steel and a higher-than-expected martensite content, in contrast to manufacturer claims. Ongoing and future studies, including Electron Backscatter Diffraction (EBSD), aim to further understand the microstructural factors influencing crack initiation and propagation. The combined studies provide a crucial baseline for distinguishing corrosion effects in DE containers, contributing to the safe and reliable long-term storage of plutonium-bearing materials.

36 MATERIALS SCIENCE↗

Quantitative non-destructive testing

The work undertaken during this period included two primary efforts. The first is a continuation of theoretical development from the previous year of models and data analyses for NDE using the Optical Thermal Infra-Red Measurement System (OPTITHIRMS) system, which involves heat injection with a laser and observation of the resulting thermal pattern with an infrared imaging system. The second is an investigation into the use of the thermoelastic effect as an effective tool for NDE. As in the past, the effort is aimed towards NDE techniques applicable to composite materials in structural applications. The theoretical development described produced several models of temperature patterns over several geometries and material types. Agreement between model data and temperature observations was obtained. A model study with one of these models investigated some fundamental difficulties with the proposed method (the primitive equation method) for obtaining diffusivity values in plates of thickness and supplied guidelines for avoiding these difficulties. A wide range of computing speeds was found among the various models, with a one-dimensional model based on Laplace's integral solution being both very fast and very accurate.

Welch, C. S.↗

Low-energy electron holographic imaging of individual tobacco mosaic virions

Modern structural biology relies on Nuclear Magnetic Resonance (NMR), X-ray crystallography, and cryo-electron microscopy for gaining information on biomolecules at nanometer, sub-nanometer, or atomic resolution. All these methods, however, require averaging over a vast ensemble of entities, and hence knowledge on the conformational landscape of an individual particle is lost. Unfortunately, there are now strong indications that even X-ray free electron lasers will not be able to image individual molecules but will require nanocrystal samples. Here, we show that non-destructive structural biology of single particles has now become possible by means of low-energy electron holography. As an example, individual tobacco mosaic virions deposited on ultraclean freestanding graphene are imaged at 1 nm resolution revealing structural details arising from the helical arrangement of the outer protein shell of the virus. Since low-energy electron holography is a lens-less technique and since electrons with a deBroglie wavelength of approximately 1 Å do not impose radiation damage to biomolecules, the method has the potential for Angstrom resolution imaging of single biomolecules.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tailoring Fibre Structure Enabled by X-ray Analytics for Targeted Biomedical Applications

The rising interest in designing fibres via spinning techniques combining the properties of various polymeric materials into advanced functionalised materials is directed towards targeted biomedical applications such as drug delivery, wearable sensors or tissue engineering. Understanding how these functional polymers exhibit multiscale structures ranging from the molecular level to nano-, micro-and millimetre scale is a key prerequisite for their challenging applications that can be addressed by a non-destructive X-ray based analytical approach. X-ray multimodalities combining X-ray imaging, scattering and diffraction allow the study of morphology, molecular structure, and the analysis of nano-domain size and shape, crystallinity and preferential orientation in 3D arrangements. The incorporation of X-ray analytics in the design process of polymeric fibers via their nanostructure under non-ambient conditions (i.e. temperature, mechanical load, humidity…) allows for efficient optimization of the fabrication process as well as quality control along the product lifetime under operating environmental conditions. Here, we demonstrate the successful collaboration between the laboratory of Biomimetic Textiles and Membranes and the Center of X-ray Analytics at Empa for the design, characterisation and optimisation of advanced functionalised polymeric fibrous material systems.

60 APPLIED LIFE SCIENCES↗

Raman Spectroscopy and Microscopy of Individual Cells andCellular Components

Raman spectroscopy provides the unique opportunity to non-destructively analyze chemical concentrations on the submicron length scale in individual cells without the need for optical labels. This enables the rapid assessment of cellular biochemistry inside living cells, and it allows for their continuous analysis to determine cellular response to external events. Here, we review recent developments in the analysis of single cells, subcellular compartments, and chemical imaging based on Raman spectroscopic techniques. Spontaneous Raman spectroscopy provides for the full spectral assessment of cellular biochemistry, while coherent Raman techniques, such as coherent anti-Stokes Raman scattering is primarily used as an imaging tool comparable to confocal fluorescence microscopy. These techniques are complemented by surface-enhanced Raman spectroscopy, which provides higher sensitivity and local specificity, and also extends the techniques to chemical indicators, i.e. pH sensing. We review the strengths and weaknesses of each technique, demonstrate some of their applications and discuss their potential for future research in cell biology and biomedicine.

42 ENGINEERING↗

The radiation valley and exotic resonances in $Wγ$ production at the LHC

The tree-level partonic angular distribution of Standard Model $Wγ$ production possesses a feature known as the Radiation Amplitude Zero (RAZ) where destructive interference causes the cross section to vanish. At the proton level the exact cancellation disappears, however, one can find a dip in the central region of the angular distributions, here called the Radiation Valley (RV). In this paper, we show how the sensitivity for $W(ℓv)γ$ resonances can be significantly improved if one focuses on events in the RV region. Using this technique, we find that the LHC could probe a larger range of resonance masses, equivalent to increasing the luminosity by a factor of 2–3 over conventional searches. The exact increase depends on the spin of the $Wγ$ resonance and exactly how it couples to electroweak gauge bosons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Non-destructive structural characterization of graphite components using mechanical resonance and deep learning

As compared to conventional nuclear reactors, microreactors have the potential to significantly reduce construction timelines and capital costs, decreasing the barriers for advanced nuclear reactor technologies. However, the lower power output of these microreactors (typically < 20 MWe) creates challenging economics if operation and maintenance costs cannot be sufficiently reduced. The compact size of these designs presents an opportunity for comprehensive in-situ structural health monitoring to provide real-time feedback in order to reduce operational costs associated with maintenance and downtime. Many microreactor concepts use graphite for both in-core neutron moderation and as a structural material, which has typically required some form of periodic and laborious inspection. This report provides a description and assessment of recent work with graphite to couple acoustic-based experimental measurements and characterization with machine learning models to mature structural health monitoring capabilities and generate benefits for the nuclear microreactor industry. With resilient embedded sensors in development in other programs funded by the US Department of Energy’s Office of Nuclear Energy and elsewhere, the work described herein builds upon previously funded efforts to mature non-destructive testing technology that relates measured vibrational signatures to structural changes, using a combination of new experimental measurements and machine learning processing. Building on past successful demonstrations of predictive workflows to identify structural changes in a hexagonal stainless steel test article with excellent acoustic propagation, we first performed baseline characterization on graphite samples with canonical geometries to ensure compatibility and confidence in the applied techniques for a material with distinctly different mechanical properties. In contrast to efforts in previous years, we worked exclusively with unidirectional vibration data that is more comparable to those expected from the existing embedded sensor technologies which are suitable for deployment in a reactor setting. Established acoustic and modern machine-learning-based characterization approaches were applied to the resulting datasets from these simple geometries. Both approaches were found to be highly capable of detecting even small geometric irregularities amongst nominally identical samples. As such, we then moved to testing these approaches for detection of artificial local stress perturbations introduced into a more complex geometry: a hexagonal block with drilled holes. A main outcome of this work is that a generalizable ML workflow can be used to detect and predict the characteristics of small artificial anomalies in a graphite component with a relevant geometry. While this work was performed using surficial vibration data, we expect the approach to be flexible and viable for other monitoring scenarios, such as those with different arrangements or types of sensor arrays. As compared to previously funded efforts, an existing ML workflow based on neural networks was enhanced through the addition of recently developed Fourier neural operators. As applied to previously collected and new vibration datasets, prediction accuracies of anomaly characterizations were greatly improved with minimal added computational cost. As trained on small durations of vibration data (tens of seconds) collected over a realistic number of locations, the model was able to reliably determine the presence of a subtle stress anomaly and begin to provide location estimates. Such an approach is likely to be viable for more relevant reactor damage scenarios for graphite components, such as progressive crack growth or creep.

36 MATERIALS SCIENCE↗

Systems and methods for direct estimation of battery parameters using only charge/discharge curves

Electrochemical models for the lithium-ion battery are useful in predicting and controlling its performance. The values of the parameters in these models are vital to their accuracy. However, not all parameters can be measured precisely, especially when destructive methods are prohibited. In some embodiments of the present disclosure, a parameter estimation approach is used to estimate the open circuit potential of the positive electrode (Up) using piecewise linear approximation together with all the other parameters of a single particle model. Up and 10 more parameters may be estimated from a single discharge curve without knowledge of the electrode chemistry using a technique such as a genetic algorithm. Different case studies were presented for estimating Up with different types of parameters of the battery model. The estimated parameters were then validated by comparing simulations at different discharge rates with experimental data.

Qi, Yanbo↗

Pore size distribution and accessible pore size distribution in bituminous coals

The porosity and pore size distribution of coals determine many of their properties, from gas release to their behavior on carbonization, and yet most methods of determining pore size distribution can only examine a restricted size range. Even then, only accessible pores can be investigated with these methods. Small-angle neutron scattering (SANS) and ultra small-angle neutron scattering (USANS) are increasingly used to characterize the size distribution of all of the pores non-destructively. Here we have used USANS/SANS to examine 24 well-characterized bituminous and subbituminous coals: three from the eastern US, two from Poland, one from New Zealand and the rest from the Sydney and Bowen Basins in Eastern Australia, and determined the relationships of the scattering intensity corresponding to different pore sizes with other coal properties. The range of pore radii examinable with these techniques is 2.5 nm to 7 {micro}m. We confirm that there is a wide range of pore sizes in coal. The pore size distribution was found to be strongly affected by both rank and type (expressed as either hydrogen or vitrinite content) in the size range 250 nm to 7 {micro}m and 5 to 10 nm, but weakly in intermediate regions. The results suggest that different mechanisms control coal porosity on different scales. Contrast-matching USANS and SANS were also used to determine the size distribution of the fraction of the pores in these coals that are inaccessible to deuterated methane, CD{sub 4}, at ambient temperature. In some coals most of the small ({approx} 10 nm) pores were found to be inaccessible to CD{sub 4} on the time scale of the measurement ({approx} 30 min - 16 h). This inaccessibility suggests that in these coals a considerable fraction of inherent methane may be trapped for extended periods of time, thus reducing the effectiveness of methane release from (or sorption by) these coals. Although the number of small pores was less in higher rank coals, the fraction of total pores that was inaccessible was not rank dependent. In the Australian coals, at the 10 nm to 50 nm size scales the pores in inertinites appeared to be completely accessible to CD{sub 4}, whereas the pores in the vitrinite were about 75% inaccessible. Unlike the results for total porosity that showed no regional effects on relationships between porosity and coal properties, clear regional differences in the relationships between fraction of closed porosity and coal properties were found. The 10 to 50 nm-sized pores of inertinites of the US and Polish coals examined appeared less accessible to methane than those of the inertinites of Australian coals. This difference in pore accessibility in inertinites may explain why empirical relationships between fluidity and coking properties developed using Carboniferous coals do not apply to Australian coals.

01 COAL, LIGNITE, AND PEAT↗

Decontamination of Genesis Array Materials by UV Ozone Cleaning

Shortly after the NASA Genesis Mission sample return capsule returned to earth on September 8, 2004, the science team discovered that all nine ultra-pure semiconductor materials were contaminated with a thin molecular organic film approximately 0 to 100 angstroms thick. The organic contaminate layer, possibly a silicone, situated on the surface of the materials is speculated to have formed by condensation of organic matter from spacecraft off-gassing at the Lagrange 1 halo orbit during times of solar exposure. While the valuable solar wind atoms are safely secured directly below this organic contamination and/or native oxide layer in approximately the first 1000 angstroms of the ultra-pure material substrate, some analytical techniques that precisely measure solar wind elemental abundances require the removal of this organic contaminate. In 2005, Genesis science team laboratories began to develop various methods for removing the organic thin film without removing the precious material substrate that contained the solar wind atoms. Stephen Sestak and colleagues at Open University first experimented with ultraviolet radiation ozone (UV/O3) cleaning of several non-flight and flown Genesis silicon wafer fragments under a pure flowing oxygen environment. The UV/O3 technique was able to successfully remove organic contamination without etching into the bulk material substrate. At NASA Johnson Space Center Genesis Curation Laboratory, we have installed an UV/O3 cleaning devise in an ambient air environment to further experimentally test the removal of the organic contamination on Genesis wafer materials. Preliminary results from XPS analysis show that the UV/O3 cleaning instrument is a good non-destructive method for removing carbon contamination from flown Genesis array samples. However, spectroscopic ellipsometry results show little change in the thickness of the surface film. All experiments to date have shown UV/O3 cleaning method to be the best non-destructive method for removing organic contamination from the surface of the Genesis materials. The UV/O3 cleaning process can also clean carbon contamination to levels below non-flight standards. This can be seen by comparing sample 60260's carbon 10667 cps with non-flight Si carbon 21675 cps. Therefore, surface carbon contamination should not hinder the analysis of solar wind.

Calaway, Michael J.↗

Fabricating High-Resolution X-Ray Collimators

A process and method for fabricating multi-grid, high-resolution rotating modulation collimators for arcsecond and sub-arcsecond x-ray and gamma-ray imaging involves photochemical machining and precision stack lamination. The special fixturing and etching techniques that have been developed are used for the fabrication of multiple high-resolution grids on a single array substrate. This technology has application in solar and astrophysics and in a number of medical imaging applications including mammography, computed tomography (CT), single photon emission computed tomography (SPECT), and gamma cameras used in nuclear medicine. This collimator improvement can also be used in non-destructive testing, hydrodynamic weapons testing, and microbeam radiation therapy.

Appleby, Michael↗

CHARACTERIZATION OF SURPLUS PLUTONIUM FOR DISPOSITION OPTIONS

The United States (U.S.) has identified 61.5 metric tons (MT) of plutonium that is permanently excess to use in nuclear weapons programs, including 47.2 MT of weapons-grade plutonium. Except for materials that remain in use for programs outside of national defense, including programs for nuclear-energy development, the surplus inventories will be stored safely by the Department of Energy (DOE) and then transferred to facilities that will prepare the plutonium for permanent disposition. Some items will be disposed as transuranic waste, low-level waste, or spent fuel. The remaining surplus plutonium will be managed through: (1) the Mixed Oxide (MOX) Fuel Fabrication Facility (FFF), to be constructed at the Savannah River Site (SRS), where the plutonium will be converted to fuel that will be irradiated in civilian power reactors and later disposed to a high-level waste (HLW) repository as spent fuel; (2) the SRS H-Area facilities, by dissolving and transfer to HLW systems, also for disposal to the repository; or (3) alternative immobilization techniques that would provide durable and secure disposal. From the beginning of the U.S. program for surplus plutonium disposition, DOE has sponsored research to characterize the surplus materials and to judge their suitability for planned disposition options. Because many of the items are stored without extensive analyses of their current chemical content, the characterization involves three interacting components: laboratory sample analysis, if available; non-destructive assay data; and rigorous evaluation of records for the processing history for items and inventory groups. This information is collected from subject-matter experts at inventory sites and from materials stabilization and surveillance programs, in cooperation with the design agencies for the disposition facilities. This report describes the operation and status of the characterization program.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutrons in Structural Biology: Challenges and Opportunities (Workshop Report)

Gaining a thorough understanding of biological systems requires building our knowledge about biological processes from the level of atoms and electrons, and up to whole organisms. Such comprehensive knowledge will allow for a predictive understanding of complex biological systems behavior. It will guide us in the design and development of novel therapeutics and vaccines to tackle existing health threats and to prepare for future pandemics, and it will provide information necessary to create new biomaterials and bio-inspired technologies through manipulation of biological macromolecules, their assemblies, single cells and even microorganisms. Reaching these goals will require a synergistic combination of multiple experimental techniques with molecular calculations and predictive simulations, and the design and development of new techniques and capabilities that bridge current knowledge and technology gaps. Neutron scattering provides unique information about the biomacromolecular structure and function and can play a major role in achieving these goals. A workshop was held to engage the scientific community in identifying pressing challenges in biochemistry, structural biology, enzymology and structure-guided drug design not solved with the current neutron scattering technologies or utilizing other structural biology techniques such as X-ray crystallography, NMR, and cryo-EM. The workshop brought together structural biology, biochemistry and computational experts, as well as early career researchers and students, creating a forum for discussing scientific advancement and collaboration. The workshop included a one-day satellite training workshop where graduate students and postdoctoral researchers were educated in the application of neutron crystallography and small-angle scattering in structural biology. Furthermore, the Instrument Scientific Advisory Board (ISAB) for the development of a macromolecular neutron diffractometer at ORNL’s Second Target Station was introduced at the workshop. The major outcome was that neutrons can provide atomic-level understanding of biomacromolecular structure, function and dynamics which is of paramount importance for addressing the identified challenges. Neutron crystallography, in particular, can resolve long-standing biochemical issues regarding enzyme function by delineating the underlying chemistry and can have a major impact on the design of small-molecule therapeutics, especially in combination with molecular computation (quantum chemistry and molecular dynamics simulations) and the emerging artificial intelligence (AI)-assisted drug design technologies. The unique properties of neutrons, including their high sensitivity to hydrogen and their non-destructive nature, make them ideal probes of biological matter. There is a palpable need in the scientific community to expand and enhance the impact of neutron sciences on biology. Neutron crystallography is the only structural biology method capable of determining positions of all hydrogen atoms in proteins, nucleic acids and their complexes at near-physiological temperatures and of unstable species at cryogenic temperatures. Moreover, neutron analysis is non-ionizing, non-destructive and does not perturb the structure or redox chemistry of active site metal centers and clusters in proteins, which can be invaluable for studying radiation-sensitive metalloprotein complexes. Further, neutron energies used in scattering applications are similar to atomic motions, permitting neutron spectroscopies to characterize the dynamics of biomacromolecules on the picosecond to microsecond timescales. The different sensitivities of neutrons to protium (H) and deuterium (D) isotopes of hydrogen allow enhanced visibility of specific parts of biological complexes through isotopic labeling. The impact of neutrons will be most powerful when neutron scattering is combined with complementary experimental techniques that use photons and electrons, and with high-performance computing. The interconnection and mutuality of the experimental and theoretical capabilities will drive discoveries in biological and health sciences to generate more complete picture of complex biological systems. The major limitation in the field of biological neutron crystallography has been signal-to-noise, demanding large samples that are difficult to produce for the majority of biomacromolecules and limiting the applicability of this technique in biological sciences. A neutron crystallography instrument at the Second Target Station will revolutionize biological science with neutrons by engaging a large scientific community of structural biologists, enabling successful neutron diffraction experiments from radically smaller biomacromolecular crystals, resolving unanswered biochemical questions, and meaningfully contributing to rational drug design. The meeting highlighted 10 grand challenges that will be addressed with this advanced capability over the next decade and beyond, and the recommendations required to help address them are given below.

59 BASIC BIOLOGICAL SCIENCES↗

NDE of PWA 1480 single crystal turbine blade material

Cantilever bending fatigue specimens were examined by fluorescent liquid penetrant and radioactive gas penetrant (Krypton) non-destructive evaluation (NDE) methods and tested. Specimens with cast, ground, or polished surface were evaluated to study the effect of surface condition on NDE and fatigue crack initiation. Fractographic and metallurgical analyses were performed to determine the nature of crack precursors. Preliminary results show that fatigue strength was lower for specimens with cast surfaces than for specimens with machined surfaces. The liquid penetrant and gas penetrant techniques both provided indications of a large population of defects on the cast surfaces. On ground or polished specimen surfaces, the gas penetrant appeared to estimate the actual number of voids more accurately than the liquid penetrant.

Klima, Stanley J.↗