Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cryogenics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Study and design of a cryogenic propellant acquisition system

The development of an acquisition system for supplying subcooled liquid hydrogen and liquid oxygen under in-orbit conditions is discussed. The system will be applied to the integrated cryogenic feed requirements for space systems such as a space shuttle cryogenic auxiliary propulsion system (APS) and main propulsion for an advanced spacecraft propulsion module (ASPM). Concepts that use the favorable surface tension characteristics of fine mesh screens are emphasized. The specific objectives of the program are: (1) to evolve conceptual designs for candidate acquisition systems, (2) to formulate the analytical models needed to analyze the systems, and (3) to generate parametric data on overall candidate system performance, characteristics, and operational features in sufficient depth to establish critical design problems and criteria to support a sound system design and evaluation.

Burge, G. W.↗

Cryogenic line insulation made from prefabricated polyurethane shells

Prefabricated polyurethane foam insulation is inexpensive and easily installed on cryogenic lines. Insulation sections are semicircular half shells. Pair of half shells is placed to surround cryogenic line. Cylindrically-shaped knit sock is pulled over insulation then covered with polyurethane resin to seal system.

Lerma, G.↗

A balloon-borne cryogenically cooled filter radiometer

The development of a cryogenically cooled filter radiometer for use with high altitude balloons is discussed. The radiometer has features which include the options for remote operation of two filter wheels each containing six filters at helium temperature and a cryogenic rotary chopper which may be run at 200 cycles per second or positioned open or closed, and a remotely operable chopped blackbody calibration source. The radiometer contains a ten inch diameter liquid nitrogen cooled Cassegrain telescope with nine individually filtered field stops in the focal plane. The telescope is mounted on a two-axis servo operated gimbal which is used to make sky scans under the control of an onboard programmer.

Debell, A. G.↗

Design, development and testing of a cryogenic temperature heat pipe for the icicle system

An analytical model was formulated for a cryogenic heat pipe, and thermal and transport analyses were developed to predict the performance characteristics of various heat pipe designs. These analyses permitted optimization of various design parameters. A series of four breadboard heat pipes were fabricated and tested to provide inputs such as internal film coefficients, minimum capillary radii, and wick permeabilities which are required for the analyses. The results of instrumentation, charging, and testing of cryogenic heat pipes were applied to the prototype heat pipes. After a thorough design analysis of three potential heat pipe wicks (slab, artery, and axial groove), the first two were chosen for application to two prototype heat pipes. Detailed designs were made of the two heat pipes and the units were fabricated. Tests were conducted which verified the integrity and safety margin of the design to withstand the internal pressure at ambient temperature and fatigue of thermal cycling. During the acceptance testing in the vacuum chamber, no difficulty was experienced in priming the slab-wick heat pipe and it met the performance design requirements. The artery-wick heat pipe would not prime with nitrogen working fluid for any test conditions.

Trimmer, D. S.↗

Design, fabrication, and testing of a cryogenic thermal diode

Cryogenic heat pipe diode applications and a new heat pipe geometry are discussed. This new geometry employs excess liquid to block the vapor space of the evaporator and part of the transport section during reverse mode conditions. An orifice plate is positioned in the pipe at the blocking meniscus location, with the opening arranged to permit proper liquid distribution in both ground tests and zero g operation. Experimental data are presented for a room temperature heat pipe modified to operate as a blocking orifice diode. The test results verify feasibility of the blocking orifice technique with the diode having a rapid shutoff characteristic. The selection of a diode for fabrication and test was based mainly on a parametric investigation of the liquid trap and liquid blockage techniques. The blocking orifice form of liquid blockage was selected for the cryogenic diode based on its high throughput, small reservoir requirement, and small energy and time required for shutoff.

Quadrini, J.↗

ERTS-C (Landsat 3) cryogenic heat pipe experiment definition

A flight experiment designed to demonstrate current cryogenic heat pipe technology was defined and evaluated. The experiment package developed is specifically configured for flight aboard an ERTS type spacecraft. Two types of heat pipes were included as part of the experiment package: a transporter heat pipe and a thermal diode heat pipe. Each was tested in various operating modes. Performance data obtained from the experiment are applicable to the design of cryogenic systems for detector cooling, including applications where periodic high cooler temperatures are experienced as a result of cyclic energy inputs.

Brennan, P. J.↗

Cryogenic nitrogen as a transonic wind-tunnel test gas

The test gas for the Langley Pilot Transonic Cryogenic Tunnel is nitrogen. Results from analytical and experimental studies that have verified cryogenic nitrogen as an acceptable test gas are reviewed. Real-gas isentropic and normal-shock flow solutions for nitrogen are compared to the ideal diatomic gas solutions. Experimental data demonstrate that for temperatures above the liquefaction boundaries there are no significant real-gas effects on two-dimensional airfoil pressure distributions. Results of studies to determine the minimum operating temperatures while avoiding appreciable effects due to liquefaction are included.

Adcock, J. B.↗

Development and test of two flexible cryogenic heat pipes

Results are presented for a comprehensive test program directed toward determining the physical and thermal performance of two flexible cryogenic heat pipes that can provide a highly efficient thermal link between a detector and a space radiator or other cooling system in spacecraft applications. A 100-200 K high-power heat pipe is tested with methane at 100-140 K while a 15-100 K low-temperature pipe is designed for operation with nitrogen and oxygen and is optimized for oxygen in the range 75-90 K. Parametric performance and design tradeoff studies are carried out to determine the optimum geometry and materials for the container and wicking systems. A spiral multiwrap wick in conjunction with braided bellows appears to be a workable solution to the problem of developing highly flexible heat transport devices for cryogenic applications.

Wright, J. P.↗

Cryogenic Hydrogen/helium Storage and Supply System, Phase 1

An existing cryogenic tank was refurbished, microspheres were installed in the tank annulus, and the thermal performance of the unit was tested. The performance data was compared with NRC-2 multilayer insulation and low emittance aluminized surfaces installed in tanks of the same basic design. The cryogenic tank modified during the program was originally designed for the Manned Orbiting Laboratory (MOL) Program, and subsequently modified by vacuum-depositing aluminum on all annulus surfaces and leaving out the NRC-2 multilayer insulation. It is concluded that the application of aluminized-microsphere insulation is not yet very predictable for tank design purposes, especially at LH2 temperature and in the presence of a vapor-cooled shield.

Norman, R. H.↗

Spacelab cryogenic propellant management experiment

The conceptual design of a Spacelab cryogen management experiment was performed to demonstrate toe desirability and feasibility of subcritical cryogenic fluid orbital storage and supply. A description of the experimental apparatus, definition of supporting requirements, procedures, data analysis, and a cost estimate are included.

Cady, E. C.↗

Evaluation of hydrogen as a cryogenic wind tunnel test gas

The nondimensional ratios used to describe various flow situations in hydrogen were determined and compared with the corresponding ideal diatomic gas ratios. The results were used to examine different inviscid flow configurations. The relatively high value of the characteristic rotational temperature causes the behavior of hydrogen, under cryogenic conditions, to deviate substantially from the behavior of an ideal diatomic gas in the compressible flow regime. Therefore, if an idea diatomic gas is to be modeled, cryogenic hydrogen is unacceptable as a wind tunnel test gas in a compressible flow situation.

Haut, R. C.↗

Cryogenic wind-tunnel technology

The cryogenic concept and the advantages it offers with respect to achieving full scale Reynolds number in a moderate size tunnel at reasonable levels of dynamic pressure are described. Aspects which must be considered during the development of a facility that uses gaseous nitrogen as the test gas are examined. These include the properties of nitrogen, particularly at high pressure; isentropic expansion and normal shock flows in nitrogen; real gas ratios; and the problem of condensation. Sources of information on cryogenic technology are cited.

Kilgore, R. A.↗

The design of models for cryogenic wind tunnels

Factors to be considered in the design and fabrication of models for cryogenic wind tunnels include high model loads imposed by the high operating pressures, the mechanical and thermodynamic properties of materials in low temperature environments, and the combination of aerodynamic loads with the thermal environment. Candidate materials are being investigated to establish criteria for cryogenic wind tunnel models and their installation. Data acquired from these tests will be provided to users of the National Transonic Facility.

Gillespie, V. P.↗

High-pressure cryogenic seals for pressure vessels

Problems associated with maintaining high pressures at cryogenic temperatures in pressure vessels are investigated. The goals were to identify the appropriate materials and design for a seal intended for cryogenic applications at pressures up to 4,080 bars (60,000 psi), and to examine the factors affecting the seal performance. The method employed and the apparatus used in a series of experimental seal system tests, and the test results are described in detail. It is concluded that the common seal designs and extrusion seal-ring materials such as Teflon, tin, and lead are not suitable. However, new seal systems developed using indium seal rings, brass or 304 stainless steel anvil rings, and two 0-rings of silicone rubber or Kel-F did prove suitable.

Buggle, A. E.↗

Cryogenic foam insulation: Abstracted publications

A group of documents were chosen and abstracted which contain information on the properties of foam materials and on the use of foams as thermal insulation at cryogenic temperatures. The properties include thermal properties, mechanical properties, and compatibility properties with oxygen and other cryogenic fluids. Uses of foams include applications as thermal insulation for spacecraft propellant tanks, and for liquefied natural gas storage tanks and pipelines.

Williamson, F. R.↗

Cryogenic-container suspension strap

Fiberglass/epoxy supporting strap holds inner shell of cryogenic storage tank away from outer shell. Strap, made of two or more links, reduces heat leakage into cryogenic fluid more efficiently than conventional suspension systems.

Vorreiter, J. W.↗

Insulating seal for cryogenic-liquid transfer

Modification to male bayonet on cryogenic transfer line prevents freezeup of transfer-line coupling and leakage of cryogenic liquid. Procedure helps leakage in plumbing and other cold fluids.

Kroenke, I. M.↗