Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “consistent filtering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Design and Optimization of Multi-Pixel Transition-Edge Sensors for X-Ray Astronomy Applications

Multi-pixel transition-edge sensors (TESs), commonly referred to as 'hydras', are a type of position sensitive micro-calorimeter that enables very large format arrays to be designed without commensurate increase in the number of readout channels and associated wiring. In the hydra design, a single TES is coupled to discrete absorbers via varied thermal links. The links act as low pass thermal filters that are tuned to give a different characteristic pulse shape for x-ray photons absorbed in each of the hydra sub pixels. In this contribution we report on the experimental results from hydras consisting of up to 20 pixels per TES. We discuss the design trade-offs between energy resolution, position discrimination and number of pixels and investigate future design optimizations specifically targeted at meeting the readout technology considered for Lynx.

Smith, Stephen J.↗

Integrated Scalable Parallel Firewall and Intrusion Detection System for High-Speed Networks

This project developed a new scalable network firewall and Intrusion Protection System (IPS) that can manage increasing traffic loads, higher network speeds, and strict Quality of Service (QoS) requirements. This new approach provides a strong foundation for next-generation network security technologies and products that address growing and unmet needs in the government and corporate sectors by delivering Optimal Network Security. Controlling access is an essential task for securing networks that are vital to private industry, government agencies, and the military. This access can be granted or denied based on the packet header or payload contents. For example, a simple network firewall enforces a security policy by inspecting and filtering the packet headers. As a complement to the firewall, an Intrusion Detection System (IDS) inspects the packet payload for known threat signatures; for example, virus or worm. Similar to a firewall policy, IDS policies consist of multiple rules that specify an action for matching packets. Each rule can specify different items, such as the signature contents and the signature location within the payload. When the firewall and IDS are merged into one device, the resulting system is referred to as an Intrusion Protection System (IPS), which provides both packet header and payload inspections. Having both types of inspections is very desirable and more manageable in a single device.

97 MATHEMATICS AND COMPUTING↗

Energetic deposition of metal ions: Observation of self-sputtering and limited sticking for off-normal angles of incidence

The deposition of films under normal and off-normal angle of incidence has been investigated to show the relevance of non-sticking of and self-sputtering by energetic ions, leading to the formation of neutral atoms. The flow of energetic ions was obtained using a filtered cathodic arc system in high vacuum and therefore the ion flux had a broad energy distribution of typically 50-100 eV per ion. The range of materials included Cu, Ag, Au, Ti, and Ni. Consistent with molecular dynamics simulations published in the literature, the experiments show, for all materials, that the combined effects of non-sticking and self-sputtering are very significant, especially for large off-normal angles. Modest heating and intentional introduction of oxygen background affect the results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calibration of the SNPP and NOAA 20 VIIRS Sensors for Continuity of the MODIS Climate Data Records

Accurate long-term sensor calibration and periodic re-processing to ensure consistency and continuity of atmospheric, land and ocean geophysical retrievals from space within the mission period and across different missions is a major requirement of climate data records. In this work, we applied the Multi-Angle Implementation of Atmospheric Correction (MAIAC)-based vicarious calibration technique over Libya-4 desert site to perform calibration analysis of Visible Infrared Imaging Radiometer Suite (VIIRS) on Suomi National Polar-orbiting Partnership (SNPP) and NOAA-20 satellites. For both VIIRS sensors we characterized residual linear calibration trends and cross-calibrated both sensors to MODerate resolution Imaging Spectroradiometer (MODIS) Aqua regarded as a calibration standard. The relative spectral response (RSR) differences were accounted for using the German Aerospace Center (DLR) Earth Sensing Imaging Spectrometer (DESIS) hyperspectral surface reflectance data. Our results agree with independent vicarious calibration results of both the MODIS/VIIRS Characterization Support Team as well as the CERES Imager and Geostationary Calibration Group within estimated uncertainty of 1–2%. Analysis of MAIAC geophysical products with the new calibration shows a high level of agreement of MAIAC aerosol, surface reflectance and NDVI records between MODIS and VIIRS. Excluding high aerosol optical depth (AOD), all three sensors agree in AOD with mean difference (MD) less than 0.01 and residual mean squared difference rmsd ∼ 0.04. Spectral geometrically normalized surface reflectance agrees within rmsd of 0.003–0.005 in the visible and 0.01–0.012 at longer wavelengths. The residual surface reflectance differences are fully explained by differences in spectral filter functions. Finally, difference in NDVI is characterized by rmsd ∼ 0.02 and MD less than 0.003 for NDVI based on VIIRS imagery bands I1/I2 and less than 0.01 for NDVI based on VIIRS radiometric bands M5/M7. In practical sense, these numbers indicate consistency and continuity in MAIAC records ensuring the smooth transition from MODIS to VIIRS.

MAIAC↗

Design and test of the Mu2e undoped CsI+SiPM crystal calorimeter

The Mu2e experiment at Fermilab will search for the charged-lepton flavour violating neutrino-less conversion of a negative muoninto an electron in the field of an aluminum nucleus. The calorimeter plays an important role in providing a fast trigger filter,excellent particle identification and a seeding for track reconstruction. Its requirements are to provide an energy (timing) resolutionbetter than 10% (0.5 ns) and a position resolution below 1 cm, for 100 MeV electrons. The calorimeter consists of two disks, eachone made of 674 un-doped CsI crystals readout by two large area arrays of 23 UV-extended SiPMs of 66 mm2dimensions.A large scale prototype (Module-0) has been constructed and tested with an electron beam in the energy range between 60 and 120MeV at the BTF of Frascati National Laboratories. Results demonstrated that this calorimeter satisfies the Mu2e requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Expression of interfacial Seebeck coefficient through grain boundary engineering with multi-layer graphene nanoplatelets

Energy filtering has been a long-sought strategy to enhance a thermoelectric material's figure of merit zT through improving its power factor. Here we show a composite of multi-layer graphene nanoplatelets (GNP) and n-type Mg 3 Sb 2 leads to the expression of an energy filtering like effect demonstrated by an increase in the material's Seebeck coefficient and maximum power factor, without impact on the material's carrier concentration. We analyse these findings from the perspective of a heterogeneous material consisting of grain and grain boundary phases, instead of a more traditional and common analysis that assumes a homogeneously transporting medium. An important implication of this treatment is that it leads to the development of an interfacial Seebeck coefficient term, which can explain the observed increase in the material's Seebeck coefficient. The contribution of this interfacial Seebeck coefficient to the overall Seebeck coefficient is determined by the relative temperature drop across the grain boundary region compared to that of the bulk material. In Te doped Mg 3 Sb 2 we show the introduction of GNP increases the interfacial thermal resistance of grain boundaries, enhancing the contribution of the interfacial Seebeck coefficient arising from grain boundaries to the overall Seebeck coefficient. Without significant detriment to the electrical conductivity this effect results in a net increase in maximum power factor. This increased interfacial thermal resistance also leads to the synergistic reduction of the total thermal conductivity. As a result, we enhance zT of the Mg 3 Sb 2 to a peak value of 1.7 near 750 K. Considering the two-dimensional nature of the grain boundary interface, this grain boundary engineering strategy could be applied to a few thermoelectric systems utilizing various two-dimensional nanomaterials.

42 ENGINEERING↗

Diel mercury concentration variations in a mercury-impacted stream

Here, filtered and particulate mercury (Hg) and methylmercury (MMHg), and associated water chemistry parameters, were evaluated bi-hourly for several 30 h periods during the summer and winter seasons at several distinct locations (downstream forested, midstream urban/suburban, upstream industrial) along a creek contaminated with high levels of inorganic Hg to determine if biogeochemical Hg and MMHg cycles respond to the daily photocycle. In summer particulate Hg and MMHg concentrations doubled overnight (excluding the upstream industrial site) concurrent with increases in turbidity and total suspended sediment; no such pattern was evident in winter. Seasonal and diel changes in the activity of macrobiota affecting the suspension of contaminated sediments are likely responsible for these patterns as other potential explanatory variables (e.g., instrument drift, pH, discharge) could not account for the range and timing of our observations. Diel patterns in filtered Hg (Hg D ) were significant only at locations and times of the year when channel shading was not present and daytime concentrations increased 22–89% above nighttime minima likely caused by direct and indirect photochemical reactions. Relationships between Hg D and dissolved organic carbon (DOC) concentration or character were inconsistent between sites. Unlike Hg D , there were significant diel patterns in filtered MMHg (MMHg D ) at all sites and times of year, with summer concentrations peaking in mid to late afternoon while the timing differed in winter, with concentrations peaking after sunset. Daily variability in MMHg D concentration ranged between 25 and 75%. The results imply key controls on net methylation occur within the stream or on the stream bed and include factors such as small-scale temperature changes in the water column and photosynthetic activity of stream biofilm. With respect to stream monitoring, results from this study indicate (1) consistent timing in stream Hg and MMHg sampling is required for accurate assessment of long-term trends, (2) in situ measurements of turbidity can be used to quantify diel dynamics of both particulate Hg and MMHg concentrations, and (3) in situ fluorescing dissolved organic matter (FDOM), a potential proxy for DOC, was not capable of resolving diel dynamics of filtered Hg or MMHg.

54 ENVIRONMENTAL SCIENCES↗

Tangential extreme ultraviolet and soft x-ray diagnostic system for time-resolved temperature measurement on the High Beta Tokamak-Extended Pulse

The High Beta Tokamak-Extended Pulse has recently incorporated a tangential multi-energy extreme ultraviolet and soft x-ray diagnostic system. This system enables measurements of the electron temperature and the examination of mode dynamics within the tokamak. While other systems have been built for poloidal views over similar temperature ranges, this is the first multi-energy tangential-view system designed to work in a temperature range below 200 eV in a tokamak. To facilitate these measurements, a filter wheel comprising five distinct groups of dual-filters has been developed and implemented. By employing a combination of 0.1 μm aluminum and 0.2 μm titanium filters, the system allows estimation of electron temperature profiles through reconstruction of the emission profile using the standard “double-foil” technique. The influence of impurities and filter oxide layers on measurement outcomes is examined. Results reveal that, while the absolute electron temperature values may exhibit some deviations, key characteristics like the electron temperature profile shape and inversion radius during sawtooth events remain consistent. This consistency confirms the system’s suitability for core plasma studies. This system has proven effective in detecting and analyzing internal magnetohydrodynamic phenomena, such as sawteeth.

Instruments & Instrumentation↗

AlGaN/GaN Core-Shell Nanofin Diodes on Si Substrates for Vertical GaN Electronics

We demonstrate plasma-assisted MBE selective-area growth of GaN/AlGaN core-shell structures on Si(111) as a path to vertical GaN devices. The selective-area growth enables the full vertical and uniform core-shell fin structures to be realized in a continuous growth without breaking vacuum. TEM images and EDS mapping of the core-shell structures show well-aligned crystal structure and sharp heterointerfaces. Dislocation filtering was observed in STEM imaging of the fin structure. P-N junction diodes fabricated with GaN/AlGaN core-shell structures reveal ideality factors as low as 1.5, and the reverse-bias leakage is consistent with trap-assisted space-charge-limited conduction. While practical challenges exist, including material-related leakage, growth-related challenges and optimization, this demonstration of p-n junction by this method may provide a path to vertical Superjunction device concepts in GaN and related materials.

Xiong, Juncheng [University of Notre Dame, IN (Uni↗

Numerical quantum clock simulations for measuring tunneling times

Here, we numerically study two methods of measuring tunneling times using a quantum clock. In the conventional method using the Larmor clock, we show that the Larmor tunneling time can be shorter for higher tunneling barriers. In the second method, we study the probability of a spin-flip of a particle when it is transmitted through a potential barrier including a spatially rotating field interacting with its spin. According to the adiabatic theorem, the probability depends on the velocity of the particle inside the barrier. It is numerically observed that the probability increases for higher barriers, which is consistent with the result obtained by the Larmor clock. By comparing outcomes for different initial spin states, we suggest that one of the main causes of the apparent decrease in the tunneling time can be the filtering effect occurring at the end of the barrier.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Solution Method for the Filtered Lifting Line Theory

The filtered lifting line theory presents a continuous form of the inviscid momentum equations of flow over a lifting device, such as a wing or rotor blade, using body forces without mathematical singularities. This theory is also consistent with an actuator line representation of a lifting device. In this work, we present a reformulation of the equations in terms of the local flow angle along the line, which allows solving the stand-alone equations using multivariate root-finding algorithms. This approach can be used to obtain a fast, computationally inexpensive solution of the loading distribution along a wing without the need to perform computational fluid dynamic simulations. We study the requirements in terms of resolution in the spanwise direction and establish the criteria for spacing and minimum amount of points required along the blade to obtain converged solutions. The solutions are compared to results from large-eddy simulations, and we observed excellent agreement with less than a percent difference in quantities along the blade between the methods.

17 WIND ENERGY↗

Further developments of capillary absorption spectrometers using small hollow-waveguide fibers

Our objective is to enhance quantification of stable carbon and oxygen isotope ratios to better than 1‰ relative isotope precision for sample sizes < 1 pico-mole. A newer variant Capillary Absorption Spectrometer (CAS) is described using a proprietary linear-taper hollow waveguide in conjunction with wavelength and frequency modulation techniques of tunable laser absorption spectrometry. Previous work used circular capillaries with uniform 1 mm ID to measure 13C/12C ratios with ≥ 20 pico-mole samples to ≤ 10 ppm (1‰ precision against standards) [1]. While performing fairly well, it generated residual modal noise due to multipath propagation in the hollow-waveguides (HWGs). This system has been utilized with laser ablation-catalytic combustion techniques to analyze small resolution (~ 25 μm spot diameter) laser ablation events on solids. Using smaller ID capillary waveguides could improve detection limits and spatial resolutions. Reducing an IR compatible hollow waveguide’s inner diameter (ID) to < 300 μm, reduces modal noise significantly for mid-IR operation, but feedback noise with high gain semiconductor lasers can become problematic. A proprietary linear-taper small waveguide (mean ID = 0.35 mm, L = 1 m) was tested to understand whether modal noise and optical feedback effects could be simultaneously reduced. We see better mode filtering and, significant reductions of feedback noise under favorable coupling of a multi-spatial mode QC laser to the smaller ID of the linear-tapered HWG. We demonstrate that better modal coupling operation is consistent with Liouville’s theorem, where greater suppression of feedback from spurious scatter within the HWG occurs by injecting the laser into the smaller ID port. Our progress on developing lighter weight, potentially fieldable alternatives to Isotope Ratio Mass Spectrometers (IRMS) with a small volume (≤ 0.1 cm3) CAS system will be discussed and compared to other competitive systems.

Kelly, James F.↗

Quantification of breast density with dual energy mammography: An experimental feasibility study

Purpose: Breast density, the percentage of glandular breast tissue, has been shown to be a strong indicator of breast cancer risk. A quantitative method to measure breast density with dual energy mammography was investigated using physical phantoms. Methods: The dual energy mammography system used a tungsten anode x-ray tube with a 50 {mu}m rhodium beam filter for low energy images and a 300 {mu}m copper beam filter for high energy images. Glandular and adipose equivalent phantoms of uniform thickness were used to calibrate a dual energy basis decomposition algorithm. Four different phantom studies were used to evaluate the technique. The first study consisted of phantoms with thicknesses of 2.5-8.5 cm in 0.5 cm steps with variable densities centered at a mean of 28%. The second study consisted of phantoms at a fixed thickness of 4.0 cm, which ranged in densities from 0% to 100% in increments of 12.5%. The third study consisted of 4.0 cm thick phantoms at densities of 25%, 50% and 75% each imaged at three areal sizes, approximately 62.5, 125, and 250 cm{sup 2}, in order to assess the effect of breast size on density measurement. The fourth study consisted of step phantoms designed to more closely mimic the shape of a female breast with maximal thicknesses from 3.0 to 7.0 cm at a fixed density of 50%. All images were corrected for x-ray scatter. Results: The RMS errors in breast density measurements were 0.44% for the variable thickness phantoms, 0.64% for the variable density phantoms, 2.87% for the phantoms of different areal sizes, and 4.63% for step phantoms designed to closely resemble the shape of a breast. Conclusions: The results of the phantom studies indicate that dual energy mammography can be used to measure breast density with an RMS error of approximately 5%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated detection of pulmonary nodules in PET/CT images: Ensemble false-positive reduction using a convolutional neural network technique

Purpose: Automated detection of solitary pulmonary nodules using positron emission tomography (PET) and computed tomography (CT) images shows good sensitivity; however, it is difficult to detect nodules in contact with normal organs, and additional efforts are needed so that the number of false positives (FPs) can be further reduced. In this paper, the authors propose an improved FP-reduction method for the detection of pulmonary nodules in PET/CT images by means of convolutional neural networks (CNNs). Methods: The overall scheme detects pulmonary nodules using both CT and PET images. In the CT images, a massive region is first detected using an active contour filter, which is a type of contrast enhancement filter that has a deformable kernel shape. Subsequently, high-uptake regions detected by the PET images are merged with the regions detected by the CT images. FP candidates are eliminated using an ensemble method; it consists of two feature extractions, one by shape/metabolic feature analysis and the other by a CNN, followed by a two-step classifier, one step being rule based and the other being based on support vector machines. Results: The authors evaluated the detection performance using 104 PET/CT images collected by a cancer-screening program. The sensitivity in detecting candidates at an initial stage was 97.2%, with 72.8 FPs/case. After performing the proposed FP-reduction method, the sensitivity of detection was 90.1%, with 4.9 FPs/case; the proposed method eliminated approximately half the FPs existing in the previous study. Conclusions: An improved FP-reduction scheme using CNN technique has been developed for the detection of pulmonary nodules in PET/CT images. The authors’ ensemble FP-reduction method eliminated 93% of the FPs; their proposed method using CNN technique eliminates approximately half the FPs existing in the previous study. These results indicate that their method may be useful in the computer-aided detection of pulmonary nodules using PET/CT images.

60 APPLIED LIFE SCIENCES↗

SU-F-T-183: Design of a Beam Shaping Assembly of a Compact DD-Based Boron Neutron Capture Therapy System

Purpose: To design a beam shaping assembly (BSA) to shape the 2.45-MeV neutrons produced by a deuterium-deuterium (DD) neutron generator and to optimize the beam output for boron neutron capture therapy of brain tumors Methods: MCNP is used for this simulation study. The simulation model consists of a neutron surface source that resembles an actual DD source and is surrounded by a BSA. The neutron source emits 2.45-MeV neutrons isotropically. The BSA is composed of a moderator, reflector, collimator and filter. Various types of materials and geometries are tested for each component to optimize the neutron output. Neutron characteristics are measured with an 2×2×2-cm{sup 3} air-equivalent cylinder at the beam exit. The ideal BSA is determined by evaluating the in-air parameters, which include epithermal neutron per source neutron, fast neutron dose per epithermal neutron, and photon dose per epithermal neutron. The parameter values are compared to those recommended by the IAEA. Results: The ideal materials for reflector and thermal neutron filter were lead and cadmium, respectively. The thickness for reflector was 43 cm and for filter was 0.5 mm. At present, the best-performing moderator has 25 cm of AlF{sub 3} and 5 cm of MgF{sub 2}. This layout creates a neutron spectrum that has a peak at approximately 10 keV and produces 1.35E-4 epithermal neutrons per source neutron per cm{sup 2}. Additional neutron characteristics, fast neutrons per epithermal neutron and photon per epithermal neutron, are still under investigation. Conclusion: Working is ongoing to optimize the final layout of the BSA. The neutron spectrum at the beam exit window of the final configuration will have the maximum number of epithermal neutrons and limited photon and fast neutron contaminations within the recommended values by IAEA. Future studies will also include phantom experiments to validate the simulation results.

07 ISOTOPE AND RADIATION SOURCES↗

To image, or not to image: class-specific diffractive cameras with all-optical erasure of undesired objects

Abstract Privacy protection is a growing concern in the digital era, with machine vision techniques widely used throughout public and private settings. Existing methods address this growing problem by, e.g., encrypting camera images or obscuring/blurring the imaged information through digital algorithms. Here, we demonstrate a camera design that performs class-specific imaging of target objects with instantaneous all-optical erasure of other classes of objects. This diffractive camera consists of transmissive surfaces structured using deep learning to perform selective imaging of target classes of objects positioned at its input field-of-view. After their fabrication, the thin diffractive layers collectively perform optical mode filtering to accurately form images of the objects that belong to a target data class or group of classes, while instantaneously erasing objects of the other data classes at the output field-of-view. Using the same framework, we also demonstrate the design of class-specific permutation and class-specific linear transformation cameras, where the objects of a target data class are pixel-wise permuted or linearly transformed following an arbitrarily selected transformation matrix for all-optical class-specific encryption, while the other classes of objects are irreversibly erased from the output image. The success of class-specific diffractive cameras was experimentally demonstrated using terahertz (THz) waves and 3D-printed diffractive layers that selectively imaged only one class of the MNIST handwritten digit dataset, all-optically erasing the other handwritten digits. This diffractive camera design can be scaled to different parts of the electromagnetic spectrum, including, e.g., the visible and infrared wavelengths, to provide transformative opportunities for privacy-preserving digital cameras and task-specific data-efficient imaging.

47 OTHER INSTRUMENTATION↗

Linear polarization variations modulo 5.6 days in HDE 226868

Results are reported for observations of variations in the linear polarization in HDE 226868 (the optical counterpart of Cyg X-1) made with a photoelastic polarimeter and a U-filter. The UV linear-polarization variations, as folded on the 5.6-day orbital period, are found to have amplitudes of 0.25% and position-angle changes of 2.7 deg. These results are shown to be consistent with the geometry and phasing required by the model of the binary system.

Nolt, I. G.↗

On the role of dimensionality and sample size for unstructured and structured covariance matrix estimation

The experimental observation that a surprisingly small sample size vis-a-vis dimension is needed to achieve good signal-to-interference ratio (SIR) performance with an adaptive predetection filter is explained. The adaptive filter requires estimates as obtained by a recursive stochastic algorithm of the inverse of the filter input data covariance matrix. The SIR performance with sample size is compared for the situations where the covariance matrix estimates are of unstructured (generalized) form and of structured (finite Toeplitz) form; the latter case is consistent with weak stationarity of the input data stochastic process.

Morgera, S. D.↗