Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “charging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Charging Experiments and Filtration Testing on Facemask Materials: Towards Goals of Full Performance Restoration of Used N95 Masks and Enhancement of Common-Fabric Facemasks

Different techniques have been developed for sanitizing N95 masks while retaining whatever charge remains on them. However, these sanitizing methods do not address the fact that the electrical charge, filtration efficacy, and breathability of such masks may be expected to degrade during long-term use based on mechanisms known in the literature. In this study, approaches to electrically (re)charging facemask filter materials were explored in response to the COVID-19 induced shortage of N95 masks. The effort consisted of charging experiments followed by filtration testing conducted at the coupon level during a month-long period (May 2020). The main focus of the work was to develop a recharging technique which could eventually be adapted and used as part of a broader full-performance restoration process for used N95 masks, e.g., which might employ simple washing by alcohol or soapy water as a preceding step for sanitization and declogging. Most tested coupons were therefore nonwoven meltblown fibrous polypropylene (PP) filter media extracted from decades old N95 masks. Keeping in mind commonly used cloth facemasks, limited trials were also performed with some commercially available fabrics. Charging was done at elevated temperature and was followed by cooling to freeze in the applied charges produced from corona discharges using different electrode configurations and parameter combinations, or from triboelectric rubbing. Charging was also focused on using potentially scalable equipment, e.g., Van de Graaff generators or consumer ionic hair products. Some degree of success was achieved with one of the fabrics and the PP filter media which was first purposefully discharged to have typical filtration efficiency (FE) of ~35%. Numerous attempts at corona charging discharged media resulted in filtration efficiency (FE) ≥ 80 – 85%. Some measure of charge robustness was also established via stable performance during loading testing. However, results where FE ≥ 90% were not reliably repeatable and no results met the FE ≥ 95% goal due to shortcomings of the charging process. The best three trials for PP media statistically met the FE ≥ 90% criteria, amounted to a small percentage of the trials relying on an ionic hair dryer, and are attributed to good embedding of charges via aerodynamic force. Triboelectric charging significantly enhanced the viability of one of the polyester fabrics –measured FE increased from 19% up to 46% while maintaining a reasonably low pressure drop.

N95↗

Scalable probabilistic estimates of electric vehicle charging given observed driver behavior

To prepare for rapid growth in global electric vehicle adoption, grid and policy planners depend on detailed forecasts of future charging demand. In this paper we propose a novel holistic, scalable, probabilistic framework to produce large-scale estimates of electric vehicle charging load for long-term planning that capture real drivers’ charging patterns. Our framework captures the uncertainty and stochasticity in charging demand by taking a graphical modeling approach. It has three core elements: driver groups, charging segment choices, and charging session time and energy requirements. The framework uses hierarchical clustering to group drivers by their charging histories, capturing their heterogeneous behaviors and preferences across different segments or types of charging. The framework uses probabilistic mixture models for each driver group’s sessions to identify the unique charging behaviors observed within each segment. We illustrate its application with a large data set from California, profiling the charging patterns and unique driver clusters it identifies. Using the model knobs representing drivers’ battery capacities, behavior, and segment access we present scenarios for California’s charging demand in 2030 with 8 million passenger electric vehicles. Peak charging demand ranged from 3.3 to 8.7 GW across scenarios. Furthermore, each was calculated in under 45 s on a laptop computer.

33 ADVANCED PROPULSION SYSTEMS↗

Modeling charging infrastructure impact on the electric vehicle market in China

The plug-in electric vehicle (PEV) is deemed as a critical technological revolution, and the governments are imposing various vehicle policies to promote its development. Meanwhile, the market success of PEVs depends on many aspects. The study reported herein integrates one’s use of charging infrastructure at home, public place and workplace into the market dynamics analysis tool, New Energy and Oil Consumption Credits (NEOCC) model, to systematically assess the charging infrastructure (home parking ratio, public charging opportunity, and charging costs) impact on PEV ownership costs and analyze how the PEV market shares may be affected by the attributes of the charging infrastructure. Compared to the charging infrastructure, the impact of battery costs is incontrovertibly decisive on PEV market shares, the charging infrastructure is still non-negligible in the PEV market dynamics. The simulation results find that the public charging infrastructure has more effectiveness on promoting the PEV sales in the PEV emerging market than it does in the PEV mature market. However, the improvement of charging infrastructure does not necessarily lead to a larger PEV market if the charging infrastructure incentives do not coordinate well with other PEV policies. Besides, the increase of public charging opportunities has limited motivations on the growth of public PEV fleets, which are highly correlated to the number of public fast charging stations or outlets. It also finds that more home parking spaces can stimulate more sales of personal plug-in hybrid electric vehicles instead of personal battery electric vehicles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Charge conservation at energies available at the BNL Relativistic Heavy Ion Collider and contributions to local parity violation observables

Relativistic heavy ion collisions provide laboratory environments from which one can study the creation of a novel state of matter, the quark-gluon plasma. The existence of such a state is postulated to alter the mechanism and evolution of charge production, which then becomes manifest in charge correlations. We study the separation of balancing charges at kinetic freeze-out by analyzing recent results on balancing charge correlations for Au + Au collisions at {radical}(s{sub NN})=200 GeV. We find that in central collisions, the spatial points from which balancing charges are emitted are characterized by smaller relative angles. These results are consistent with the expectation that charge production occurred later in the collision, as would be expected for delayed hadronization. An alternative explanation would be that the charges were produced early, perhaps with a different mechanism where the charge production mechanism was altered from string breaking which tends to separate the charges in relative rapidity. The alternative explanation would also rely on the diffusion of charges being small. In addition we calculate the contributions from charge-balance correlations to STAR's local parity violation observable. We find that local charge conservation, when combined with elliptic flow, explains the bulk of STAR's measurement.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

DOE EV Data Collection - Charging Data

Charging data are collected from one of three sources, each with varying levels of additional information. These sources, in approximate order from most to least additional information, are: • The electric vehicle supply equipment (charger) • Onboard the vehicle itself • From a utility submeter. Many chargers provide software that allows for the collection and reporting of charging session data. If unavailable, data may be recorded by the charging vehicle’s onboard systems. If neither of these options is available, data can be acquired from utility submeters that simply track the energy flowing to one or more chargers. Data collected directly from the electric vehicle supply equipment (EVSE) are typically the most accurate and highest frequency. However, it is not always possible to discern which exact vehicle is being charged during any one session. EVSE-side data can be identified where a single charger ID but a range of vehicle IDs are present (e.g., CH001, EV001-EV005). Data collected from the vehicle’s onboard systems usually does not provide information on which exact charger is being used. Vehicle-side data can be identified where a single Vehicle ID but a range of Charger IDs are present (e.g., EV001, CH001-CH005). Data collected from utility submeters provide no information on which specific vehicle is charging or which specific charger is in use. Submeter data can be identified where multiple Vehicle IDs and multiple Charger IDs are present, but only a single Fleet ID is present (e.g., EV001-EV005, CH001-CH005, Fleet01). The **Charge Data Daily/Session Dictionaries** contains definitions for each available parameter collected as part of an individual charging session, aggregated at either a daily or session level. The parameters available will vary between vehicles and chargers. The **Charger Attributes** table contains specific charger characteristics, coded to at least one anonymous Charger ID and linked to either a single or a range of Vehicle IDs. Vehicle ID can be used as a key between charging data and vehicle attribute tables. The **Charger Attributes Data Dictionary** contains definitions for each available parameter collected on the physical and operational characteristics of the charging hardware itself. The **Vehicle Attributes Data Dictionary** contains definitions for each available parameter associated with a vehicle’s physical and functional attributes and fleet context. The **Vehicle Attributes** table contains specific vehicle characteristics, coded to an anonymous Vehicle ID. This Vehicle ID can be used as a key between vehicle data and vehicle attribute tables, and in cases where charging data are supplied, links a vehicle with the charger(s) that supplied it power. The **Charging Data** tables contain the data from each charger’s operations, coded to at least one anonymous Charger ID and linked to either a single or a range of Vehicle IDs. Vehicle ID can be used as a key between charging data and vehicle attribute tables. Data is being uploaded quarterly through 2023 and subject to change until the conclusion of the project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimization for Single-Spike X-Ray FELs at LCLS with a Low Charge Beam

The Linac Coherent Light Source is an x-ray free-electron laser at the SLAC National Accelerator Laboratory, which is operating at x-ray wavelengths of 20-1.2 Angstrom with peak brightness nearly ten orders of magnitude beyond conventional synchrotron radiation sources. At the low charge operation mode (20 pC), the x-ray pulse length can be <10 fs. In this paper we report our numerical optimization and simulations to produce even shorter x-ray pulses by optimizing the machine and undulator setup at 20 pC charge. In the soft x-ray regime, with combination of slotted-foil or undulator taper, a single spike x-ray pulse is achievable with peak FEL power of a few 10s GW. Linac Coherent Light Source (LCLS), the world's first hard x-ray Free electron laser (FEL), has started operation since 2009. With nominal operation charge of 250 pC, the generated x-ray pulse length is from 70 fs to a few hundred fs. This marks the beginning of a new era of ultrashort x-ray sciences. In addition, a low charge (20pC) operation mode has also been established. Since the collective effects are reduced at the low charge mode, we can increase the compression factor and still achieve a few kA peak current. The expected electron beam and x-ray pulses are less than 10 fs. There are growing interests in even shorter x-ray pulses, such as fs to sub-fs regime. One of the simple solutions is going to even lower charge. As discussed, single-spike x-ray pulses can be generated using 1 pC charge. However, this charge level is out of the present LCLS diagnostic range. 20 pC is a reasonable operation charge at LCLS, based on the present diagnostic system. At 20 pC in the soft x-ray wavelength regime, we have experimentally demonstrated that FEL can work at undercompression or over-compression mode, such as 1 degree off the full-compression; at full-compression, however, there is almost no lasing. In hard x-ray wavelength regime, we observed that there are reasonable photons generated even at full-compression mode, although the photon number is less than that from under-compression or over-compression mode. Since we cannot measure the x-ray pulse length at this time scale, the machine is typically optimized for generating maximum photons, not minimum pulse length. In this paper, we study the methods of producing femtosecond (or single-spike) x-ray pulses at LCLS with 20 pC charge, based on start-to-end simulations. Figure 1 shows a layout of LCLS. The compression in the second bunch compressor (BC2) determines the final e-beam bunch length. However, the laser heater, dog-leg after the main linac (DL2) and collective effects also affect the final bunch length. To adjust BC2 compression, we can either change the L2 phase or BC2 R{sub 56}. In this paper we only tune L2 phase while keep BC2 R{sub 56} fixed. For the start-to-end simulations, we used IMPACT-T and ELEGANT tracking from the photocathode to the entrance of the undulator, after that the FEL radiation was simulated with GENESIS. IMPACT-T tracks about 10{sup 6} particles in the injector part until 135 MeV, including 3D space charge force. The output particles from IMPACT-T are smoothed and increased to 12 x 10{sup 6} to reduce high-frequency numerical noise for subsequent ELEGANT simulations, which include linear and nonlinear transport effects, a 1D transient model of CSR, and longitudinal space charge effects, as well as geometric and resistive wake fields in the accelerator. In GENESIS part, the longitudinal wake field from undulator chamber and longitudinal space field are also included.

43 PARTICLE ACCELERATORS↗

VARIABLE CHARGE SOILS: MINERALOGY AND CHEMISTRY

Soils rich in particles with amphoteric surface properties in the Oxisols, Ultisols, Alfisols, Spodosols and Andisols orders (1) are considered to be variable charge soils (2) (Table 1). The term “variable charge” is used to describe organic and inorganic soil constituents with reactive surface groups whose charge varies with pH and ionic concentration and composition of the soil solution. Such groups are the surface carboxyl, phenolic and amino functional groups of organic materials in soils, and surface hydroxyl groups of Fe and Al oxides, allophane and imogolite. The hydroxyl surface groups are also present on edges of some phyllosilicate minerals such as kaolinite, mica, and hydroxyl-interlayered vermiculite. The variable charge is developed on the surface groups as a result of adsorption or desorption of ions that are constituents of the solid phase, i.e., H+, and the adsorption or desorption of solid-unlike ions that are not constituents of the solid phase. Highly weathered soils and subsoils (e.g., Oxisols and some Ultisols, Alfisols and Andisols) may undergo isoelectric weathering and reach a “zero net charge” stage during their development. They usually have a slightly acidic to acidic soil solution pH, which is close to either the point of zero net charge (PZNC) (3) or the point of zero salt effect (PZSE) (3). They are characterized by high abundances of minerals with a point of zero net proton charge (PZNPC) (3) at neutral and slightly basic pHs; the most important being Fe and Al oxides and allophane. Under acidic conditions, the surfaces of these minerals are net positively charged. In contrast, the surfaces of permanent charge phyllosilicates are negatively charged regardless of ambient conditions. Variable charge soils therefore, are heterogeneous charge systems.

highly weathered soils↗

Controlled workplace charging of electric vehicles: The impact of rate schedules on transformer aging

To accelerate adoption of non-residential charging for electric vehicles, sites must maximize utilization of existing electrical infrastructure. In this study we model electric vehicle charging at a workplace using real charging data and evaluate the lifetime of the site’s transformer as the number of charging stations is incrementally increased. We implement and compare a range of control schemes for workplace charging including minimizing the peak load, capping the total load, minimizing bills under different rate structures with time-of-use energy costs and demand charges, and directly minimizing the transformer’s aging. These are compared by the number of vehicles they allow the transformer to support, the transformer’s health, and the operator’s electricity bill. We draw a connection between minimizing the peak load and improving the transformer’s health. We observe that minimizing the electricity bill is the best scheme by both criteria when the bill includes a demand charge; in our experiment it allowed the infrastructure to support over 67% more cars than under uncontrolled charging. To protect the transformer we recommend that demand charges or capacity management be applied to parking lots of charging electric vehicles with high infrastructure utilization, and operators schedule charging to minimize their electricity bills.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Investigation of long-term light stability of negative charge injected into oxide-nitride-oxide passivation stack of crystalline silicon solar cells

A negatively charged oxide-nitride-oxide stack for field-effect passivation of crystalline silicon solar cells is discussed. The negative charge was injected into the stack by a plasma charge injection technology. Charge stability was studied by exposing samples to AM1.5 simulation visible light and full-spectrum light at temperatures ranging from 55 to 78 °C for up to 300 h. Charge injection and loss were quantified based on shifts in the flatband voltage of capacitance–voltage curves measured with a mercury probe. The most probable mechanism of charge loss was found to be diffusion of negative charged hydrogen atoms through nitride and bottom oxide. The optimum recipe for each layer of the stack was investigated to minimize the loss of injected charge. The flatband voltage decay of the optimized stack was found to fit a power-law trend, suggesting the dispersive transport of hydrogen atoms with a dispersion parameter of ~0.06–0.07. The optimized stack is projected to maintain a negative charge density of about 3.6 × 10 12 cm –2 or more after 25 years of field operation in an environment such as Arizona, which would be sufficient for field-effect passivation under one-sun illumination. Furthermore, the high stability of the negative injected charge makes the plasma charging technology a safer and lower cost alternative to Al 2 O 3 -passivation technology commonly used to passivate p-type surfaces.

14 SOLAR ENERGY↗

Enabling Fast Charging: A Technology Gap Assessment

The transportation sector accounts for the largest percentage of energy use in the United States. Decreasing energy consumption across this sector, especially in commercial light duty transportation, is essential for the U.S. to gain energy independence. Recently, powertrain electrification with plug-in electric vehicles (PEVs) have gained traction as an alternative due to their inherent efficiency advantages compared to the traditional internal combustion engine vehicle (ICEV). Accounting for 500,000 vehicle on the road today, these PEVs will reduce oil imported into the U.S. by five billion gallons and save two billion dollars in fuel costs to consumers over their useful life. Though there are many different classes of PEV, the intent of this study is to focus on non-hybrid powertrains, or battery electric vehicles (BEVs). Despite rapid drops in cost within the BEV powertrain of over 4x in the last 10 years, the PEV market still only accounts for approximately 1% of new light duty vehicle sales annually. Though BEV powertrain costs are not quite at parity with the ICEV, another gap to wider adoption of BEVs that have been identified is the ability to refuel quickly, or to fast charge. Though the majority of recharging BEVs is done at home, having access to fast charge stations has a big impact on BEV utility from a consumer perspective. To address the fast charge barrier, charging at 350 kW, or extreme fast charging (XFC), has been proposed and will serve as the basis for discussion in this report. Studies have shown that in areas where drivers have access to 50 kW or 120 kW fast charge stations, annual electric vehicle miles traveled (eVMT) increased by over 25%, even in cases where fast charging was used for 1-5% of total charging events [1, 2]. Having access to these fast charge stations can help alleviate the “range anxiety” that is cited as a common reason for consumers to hesitate to buy a BEV. Though, to be truly competitive to the ICEV refueling experience, even higher power stations are necessary. These extreme fast charge stations (XFC) should be able to recharge a BEV in less than 10 minutes and provide approximately 175 additional miles of driving. However, this introduces a host of new challenges that need to be addressed. As a result, it is expected that packs designed to meet XFC will be significantly more expensive initially than BEVs optimized for range that can reach 140kW with current technology. From the battery cell to the power grid to which these 350 kW chargers are connected, this study will discuss the issues that need to be addressed at each level in order to implement a 350 kW charging network. Although this report is U.S.-focused, the findings should be applicable to other countries with mature automotive infrastructures.

25 ENERGY STORAGE↗

Electric Vehicles at Scale (EVs@Scale) Laboratory Consortium Deep-Dive Technical Meetings: High Power Charging (HPC) Summary Report

Electric vehicle (EV) adoption will change the composition of EV charging load to higher-power charging as more medium- (MD) and heavy-duty (HD) applications are electrified, and as all vocations, including light-duty (LD) vehicles, are capable of faster charging. These shifts provide the opportunity for high-power charging (HPC) and facility equipment to evolve and improve efficiency, cost, and space. High-Power Electric Vehicle Charging Hub Integration Platform (eCHIP) project designs and develops a high-power, interoperable charging experimental platform to research, develop, and demonstrate the integration approaches and technology solutions. The project addresses (1) interconnection and management of a grid-tied inverter; (2) development of a DC distribution system that is responsible for system energy management, interoperability, and DC protection; (3) modular DC/DC conversion for vehicle charging; (4) EV charging interface and DC/DC integration; and (5) smart charge control and vehicle-to-edge (vehicle-to-building [V2B], vehicle-to-everything [V2X]) capability. This summary presentation is the first technical progress output of the project. It provides insight for the first deep-dive technical meeting outputs in terms of research presentations and also includes summary of the discussions occurred in the follow-up breakout sessions. The summary presentation covers three technical areas: (1) HPC: State of the art power architectures and the design of the power electronics, (2) Modeling, energy management, and power control in the HPC station, and (3) Next Generation Profiles for high power charging characterization.

ADVANCED PROPULSION SYSTEMS↗

Carbons with Regular Pore Geometry Yield Fundamental Insights into Supercapacitor Charge Storage

We conduct molecular dynamics simulations of electrical double-layer capacitors (EDLCs) using a library of ordered, porous carbon electrode materials called zeolite templated carbons (ZTCs). The well-defined pore shapes of the ZTCs enable us to determine the influence of pore geometry on both charging dynamics and charge storage mechanisms in EDLCs, also referred to as supercapacitors. We show that charging dynamics are negatively correlated with the pore-limiting diameter of the electrode material and display signatures of both progressive charging and ion trapping. However, the equilibrium capacitance, unlike charging dynamics, is not strongly correlated to commonly used, purely geometric descriptors such as pore size. Instead, we find a strong correlation of capacitance to the charge compensation per carbon (CCpC), a descriptor we define in this work as the average charge of the electrode atoms within the coordination shell of a counterion. A high CCpC indicates efficient charge storage, as the strong partial charges of the electrode are able to screen counterion charge, enabling higher ion loading and thus more charge storage within the electrode at a fixed applied voltage. We determine that adsorption sites with a high CCpC tend to be found within pockets with a smaller radius of curvature, where the counterions are able to minimize their distance with multiple points on the electrode surface, and therefore induce stronger local partial charges.

25 ENERGY STORAGE↗

Evaluation of Changes to the MTR Fuel Dissolution Flowsheet to Increase the Number of L-Bundles Charged to a Dissolver

Material Test Reactor (MTR) fuels are dissolved in the H-Canyon facility using a Hg-catalyzed, HNO₃ dissolution flowsheet. The flowsheet is based on experimental work in which laboratory-scale experiments were used to provide bounding values for both offgas and H₂ generation rates. The generation of H₂ gas, primarily from the dissolution of Al, is controlled by limiting the surface area exposed to the solution. The number of L-Bundles charged and their submergence level defines the exposed surface area which is directly proportional to the H₂ generation rate. For the MTR fuel dissolution flowsheet, the maximum number of L-Bundles which can be charged to a dissolver was specified as a function of the Al concentration in the solution and the submergence level of the bundle. The MTR fuels are currently dissolved in the 6.1D dissolver. To reach the desired terminal Al concentration, a total of 12 L-Bundles of fuel are dissolved per batch. Depending on the submergence level being used in the dissolver, the 12 bundles are dissolved in three charges of four bundles per charge or in a sequence of three, four, and five bundles. However, if six L-Bundles could be dissolved in the initial charge, a dissolver batch could be completed in two dissolutions instead of three. To assess the feasibility of dissolving six bundles in the first charge, the Savannah River National Laboratory evaluated changes to the MTR flowsheet which increase the number of bundles which can be charged to a dissolver. Since the development of the existing MTR fuel dissolution flowsheet, improved offgas measurement methods have been developed to more accurately calculate the offgas composition and generation rate during laboratory-scale dissolutions. In the first part of this study, improvements in the calibration model for the Raman spectrometer (used for offgas characterization) and a more effective data smoothing routine were applied to existing data. The uncertainty in the offgas composition data used to define the MTR fuel dissolution flowsheet were subsequently re-evaluated which resulted in an approximate 50% reduction in the uncertainty of the H₂ gas concentration measurements. The reduced uncertainty was used in new calculations to define the maximum number of L-Bundles which can be charged to either the 6.1D or 6.4D dissolver as a function of the Al concentration. With the reduced uncertainty in the H₂ concentration measurements, a flowsheet was defined which supported initially charging 6 bundles to a dissolver. This flowsheet is based on the use of 0.002 M Hg, an L-Bundle immersion depth of 54 in., an air sparge/purge flowrate of 40 scfm, an iodine reactor operating temperature of 200 °C, and not exceeding 60% of the H₂ LFL in the dissolver offgas. In the second phase of this study, calculations were performed to assess the impact of changing various operating parameters to increase the number of L-Bundles charged to an H-Canyon dissolver. Applying the improved offgas measurement techniques including the reduced uncertainty in the H₂ concentration measurements to the existing data, the number of bundles of MTR fuel which can be charged to either the 6.1D or 6.4D dissolver were calculated based on varying the bundle immersion depth (44-60 in.), air sparge/purge flowrate (40-60 scfm), iodine reactor operating temperature (150-200 °C), and the percentage of the H₂ LFL which must not be exceeded (60-76%). Qualitatively, the percentage of the LFL had the largest influence on the maximum number of bundles which can be charged to a dissolver followed by the air sparge/purge flowrate, L-Bundle immersion depth, and the iodine reactor operating temperature. During the evaluation of each variable, the other variables were held at the baseline flowsheet conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Charging and coagulation of radioactive and nonradioactive particles in the atmosphere

Charging and coagulation influence one another and impact the particle charge and size distributions in the atmosphere. However, few investigations to date have focused on the coagulation kinetics of atmospheric particles accumulating charge. This study presents three approaches to include mutual effects of charging and coagulation on the microphysical evolution of atmospheric particles such as radioactive particles. The first approach employs ion balance, charge balance, and a bivariate population balance model (PBM) to comprehensively calculate both charge accumulation and coagulation rates of particles. The second approach involves a much simpler description of charging, and uses a monovariate PBM and subsequent effects of charge on particle coagulation. The third approach is further simplified assuming that particles instantaneously reach their steady-state charge distributions. It is found that compared to the other two approaches, the first approach can accurately predict time-dependent changes in the size and charge distributions of particles over a wide size range covering from the free molecule to continuum regimes. The other two approaches can reliably predict both charge accumulation and coagulation rates for particles larger than about 0.04 micrometers and atmospherically relevant conditions. These approaches are applied to investigate coagulation kinetics of particles accumulating charge in a radioactive neutralizer, the urban atmosphere, and an atmospheric system containing radioactive particles. Limitations of the approaches are discussed.

07 ISOTOPE AND RADIATION SOURCES↗

"Electrostructural Phase Changes" In Charged Particulate Clouds: Planetary and Astrophysical Implications

There is empirical evidence that freely-suspended triboelectrostatically charged particulate clouds of dielectric materials undergo rapid conversion from (nominally) monodispersed "aerosols" to a system of well-defined grain aggregates after grain motion or fluid turbulence ceases within the cloud. In United States Microgravity Laboratory Space Shuttle experiments USML-1 and USML-2, it was found that ballistically-energized grain dispersions would rapidly convert into populations of filamentary aggregates after natural fluid (air) damping of grain motion. Unless continuously disrupted mechanically, it was impossible to maintain a non-aggregated state for the grain clouds of sand-size materials. Similarly, ground- based experiments with very fine dust-size material produced the same results: rapid, impulsive "collapse" of the dispersed grains into well-defined filamentary structures. In both ground-based and microgravity experiments, the chains or filaments were created by long-range dipole electrostatic forces and dipole-induced dielectric interactions, not by monopole interactions. Maintenance of the structures was assisted by short-range static boundary adhesion forces and van der Waals interactions. When the aggregate containers in the USML experiments were disturbed after aggregate formation, the quiescently disposed filaments would rearrange themselves into fractal bundles and tighter clusters as a result of enforced encounters with one another. The long-range dipole interactions that bring the grains together into aggregates are a product of randomly-distributed monopole charges on the grain surfaces. In computer simulations, it has been shown that when the force vectors of all the random charges (of both sign) on a grain are resolved mathematically by assuming Coulombic interaction between them, the net result is a dipole moment on individual grains, even though the grains are electrically neutral insofar as there is no predominance, on their surface, of one charge sign over another. The random charges of both sign derive from natural grain-to-grain interactions that produce triboelectrification via charge exchange every time grain surfaces make contact with one another. The conversion from a random distribution of grains (upon which there are randomly distributed charges) into an organization of electrostatically-ordered aggregates, can be regarded (within the framework of granular-material science) as an "electrical or Coulombic phase change" of the particulate cloud. It is not totally dissimilar from the more normal phase-change concept in which, for example, a gas with long free-path-molecules suddenly becomes a solid as a result of structural ordering of the molecules (notably, also the result of electronic forces, albeit at a different scale). In both the gas-to-solid case, and the aerosol-to-aggregate case, the same materials and charges are present before and after the phase change, but their arrangement now has a higher degree of order and a lower-energy configuration. An input of energy into the system is required to reverse the situation. The aggregates in the USML experiments were observed to undergo at least two phase changes as noted above. The point about phase changes, and by implication, the "electrostructural" reorganizations in particulate clouds, is the following: (a) they can occur very rapidly, almost spontaneously, above a critical cloud density, (b) in going from a higher energy state to a lower energy state, they convert to a denser system, (c) energy must be required to reverse the situation, implying that energy is released during the high-to-low energy phase change. In applying this information to natural particulate clouds, some inferences can be made (it is stressed that reference is still to dielectric materials attracted by dipole forces). There are several natural settings to which the USML observations apply, and to which the phase-change implications likewise apply. Dense clouds of triboelectrically-charged, kinetically-energized grains are to be found in volcanic eruptions (particularly on earth), aeolian dust storms (particularly on Mars), meteorite impact ejecta curtains (on all planets), in "immature" debris rings around planets (e.g., that from which our own Moon may have condensed), and in gravitationally collapsing protoplanetary dust/planetesimal debris disks where dielectric granules are being increasingly brought into collisional relationships with one another (increasing both charge exchange and physical proximity). It is noted that in many of these cases, the degree of electrical charging on the grains is likely to be much higher than that in the USML experiments where charging was not enhanced above the "normal", naturally encountered level for the particular materials (quartz, glass, and various silicate minerals). Application of the phase-change concept suggests that volcanic, aeolian, and impact debris clouds may, under certain circumstances, undergo rapid, impulsive, or even catastrophic collapse into a denser state that will lead to rapid precipitation or fall-out of suspended particulates. Although this idea has been suggested previously by the author , the phase change concept possibly permits some new insights into cloud-system behavior. For example, in a protoplanetary debris disk, the work of gravity may suddenly be enhanced by electrostatically driven collapse of the system when materials reach a critical intergranular spacing or grain number density. This might reduce the rate of planet formation by orders of magnitude (considering the ratio of g-forces to electrostatic ones for very small grains in close proximity), and indeed, it might drive the collapse into a system configuration that would perhaps not be created by gravity alone. Additional information is contained in the original.

Marshall, J. R.↗

Assessment and Control of Spacecraft Charging Risks on the International Space Station

The International Space Station (ISS) operates in the F2 region of Earth's ionosphere, orbiting at altitudes ranging from 350 to 450 km at an inclination of 51.6 degrees. The relatively dense, cool F2 ionospheric plasma suppresses surface charging processes much of the time, and the flux of relativistic electrons is low enough to preclude deep dielectric charging processes. The most important spacecraft charging processes in the ISS orbital environment are: 1) ISS electrical power system interactions with the F2 plasma, 2) magnetic induction processes resulting from flight through the geomagnetic field and, 3) charging processes that result from interaction with auroral electrons at high latitude. Recently, the continuing review and evaluation of putative ISS charging hazards required by the ISS Program Office revealed that ISS charging could produce an electrical shock hazard to the ISS crew during extravehicular activity (EVA). ISS charging risks are being evaluated in an ongoing measurement and analysis campaign. The results of ISS charging measurements are combined with a recently developed model of ISS charging (the Plasma Interaction Model) and an exhaustive analysis of historical ionospheric variability data (ISS Ionospheric Specification) to evaluate ISS charging risks using Probabilistic Risk Assessment (PRA) methods. The PRA combines estimates of the frequency of occurrence and severity of the charging hazards with estimates of the reliability of various hazard controls systems, as required by NASA s safety and risk management programs, to enable design and selection of a hazard control approach that minimizes overall programmatic and personnel risk. The PRA provides a quantitative methodology for incorporating the results of the ISS charging measurement and analysis campaigns into the necessary hazard reports, EVA procedures, and ISS flight rules required for operating ISS in a safe and productive manner.

Koontz, Steve↗

Spacecraft Charging Analysis of a CubeSat

Spacecraft charging occurs when charged particles from the surrounding space plasma environment contact a spacecraft and unequal charging currents result in a net charge density accumulation on or in spacecraft materials. Charging becomes a threat when differential potentials between two points on the spacecraft or between the spacecraft and the ambient space environment build to the level that electric fields associated with the potentials exceed the electric breakdown strength of the spacecraft materials and electrostatic discharge arcs are generated. Electrostatic discharges resulting from spacecraft charging can adversely affect telemetry and cause irreparable damage to electronics. Other spacecraft charging effects include damage of solar arrays and thermal protection, enhancement of contamination of surfaces, and degradation of optics. Typically, the large government and commercial space programs include spacecraft charging analysis as part of the design process. CubeSat projects, however, usually do not have the time or funding to include a spacecraft charging analysis due to their low budget and quick-turnaround requirements. CubeSat projects also tend to rely heavily on commercial "off-the-shelf" products, many of which are not qualified for use in space, and are particularly vulnerable to the effects of the space environment. As the demand for longer and more complex CubeSat missions increases, it is becoming more and more important to consider the effects of spacecraft charging in the design process. Results of surface charging analysis using Nascap-2k on a typical CubeSat design for a polar orbit scenario are illustrated. These results show that for a polar orbiting CubeSat, spacecraft charging could be an issue and steps should be taken to mitigate the effects for these small satellites.

Willis, Emily M.↗

Measuring momentum for charged particle tomography

Methods, apparatus and systems for detecting charged particles and obtaining tomography of a volume by measuring charged particles including measuring the momentum of a charged particle passing through a charged particle detector. Sets of position sensitive detectors measure scattering of the charged particle. The position sensitive detectors having sufficient mass to cause the charged particle passing through the position sensitive detectors to scatter in the position sensitive detectors. A controller can be adapted and arranged to receive scattering measurements of the charged particle from the charged particle detector, determine at least one trajectory of the charged particle from the measured scattering; and determine at least one momentum measurement of the charged particle from the at least one trajectory. The charged particle can be a cosmic ray-produced charged particle, such as a cosmic ray-produced muon. The position sensitive detectors can be drift cells, such as gas-filled drift tubes.

Morris, Christopher↗