Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calibrated”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

JPSS-1 VIIRS Solar Diffuser Witness Sample BRF Calibration Using a Table-Top Goniometer at NASA GSFC

In support of the prelaunch calibration of the Joint Polar Satellite System-1 (JPSS-1) Visible Infrared Imaging Radiometer Suite (VIIRS), the Bidirectional Reflectance Factor (BRF) and Bidirectional Reflectance Distribution Function (BRDF) of a VIIRS solar diffuser (SD) witness sample were determined using the table-top goniometer (TTG) located in the NASA GSFC Diffuser Calibration Laboratory (DCL). The BRF of the sample was measured for VIIRS bands in the reflected solar wavelength region from 410 nm to 2250 nm. The new TTG was developed to extend the laboratory’s BRF and BRDF measurement capability to wavelengths from 1600 to 2250 nm and specifically for the VIIRS M11 band centered at 2250 nm. We show the new features and capabilities of the new scatterometer and present the BRF and BRDF results for the incident/scatter test configuration of 0°/45° and for a set of angles representing of the VIIRS on-orbit solar diffuser calibration. The BRF and BRDF results of the SD witness were used to assist in finalizing the set of BRF values of J1 VIIRS SD to be used on-orbit. Comparison of the BRF results between the JPSS-1 VIIRS SD witness sample and the flight SD panel was made by varying different sample clocking orientations and by analyzing the ratio of BRF to total hemispherical reflectance in effort to minimize the uncertainty of the extrapolated flight BRF value at 2250 nm. Furthermore, differences between the prelaunch BRF results and those used in the VIIRS on-orbit BRF lookup table were examined to improve the VIIRS BRF calibration for future missions.

Zeng, Jinan↗

Methods of Earth View Based Calibration of the Response Versus Scan Angle of the MODIS Reflective Solar Bands

The MODIS instruments on the Terra and Aqua spacecraft are cross-track scanning radiometers that view the Earth scene, a space view port, and the on-board calibrators using a two-sided scan mirror. The reflectivity of the scan mirror varies with the angle of the incident light, and changes in this response versus scan angle (RVS) need to be tracked on orbit in order to maintain accurate calibration. In this paper, we review various methods of RVS calibration of the reflective solar bands using pseudo-invariant desert targets and discuss potential advantages and disadvantages for use in future calibration.

Twedt, Kevin A.↗

Initial Calibrations and Wind Tunnel Test Results for an In-Flow Reference Array Using New In-Flow Acoustic Sources in Four Array Mount Configurations

This paper describes efforts to develop a small in-flow phased microphone array as a reference acoustic sensor and quantify its level-measurement accuracy with new in-flow calibration sources. The devices can be applied to a wide variety of in- and out-of-flow measurement applications and test facilities. Recent tests of the array and two calibration sources in the NASA Anechoic Chamber and Army 7- by 10-foot Wind Tunnel at NASA Ames Research Center demonstrated that the array was functional over a frequency range of 2 to 100 kilohertz for emission angles of 92 degrees, 108 degrees, and 120 degrees, and Mach numbers of 0, 0.15, and 0.25. The array and calibration sources were then used to assess the relative effects of array installation on background noise and level measurement accuracy by locating the array in the flow (strut- and wall-mounted) as well as outside the flow behind a porous wall screen and a free shear layer. The wind tunnel array measurements were compared with anechoic chamber measurements using discrete microphones at the same source distance and emission angles. At 92 degrees, the noise floor and attenuation spectra were comparable (within 5 decibels) for each installation from 2 to 30 kilohertz. At higher angles, the array installation behind the Kevlar screen had the lowest noise floor at M = 0.15 and 0.25. The array installation 10 inches (maximum available distance) behind a free shear layer had higher background noise that is typically reduced to a lower level by moving the array back further from the flow. For emission angles greater than 92 degrees, both the Kevlar and free shear layer installations exhibited stronger attenuations in measured level, beginning at lower frequencies than either the wall- or strut-mount configurations. Additional array and calibration source units of the same design are being tested at NASA’s Glenn Research Center and Langley Research Center in their aeroacoustic research facilities in an effort to improve measurement accuracy and repeatability.

Aeroacoustic Wind Tunnel Research↗

The New (Version 4) Calibration of the Nighttime 532nm Channel of the CALIPSO Lidar

The data products from the Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) on board Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations (CALIPSO) were recently updated following the implementation of a new (version 4.1) calibration algorithm for all the level 1 products. We present the motivation for and the implementation of the version 4.1 nighttime 532 nm parallel channel measurements. This is the most fundamental calibration of CALIOP data since all other measurements, i.e the 532 nm nighttime perpendicular, daytime 532 nm as well as 1064 nm are tied to this calibration. The new calibration is shown to resolve the discrepancies in the earlier version and also leads to an improved representation of the stratospheric aerosols. Initial validation results using ground based and airborne lidar measurements are also presented.

Kar, J.↗

Comparison of MODIS Solar Diffuser Stability Monitor Calibration Results for Different Operational Configurations

The MODIS instruments on the Terra and Aqua spacecraft use a sunlit solar diffuser (SD), with an optional SD attenuation screen (SDS), to calibrate the reflective solar bands. A solar diffuser stability monitor (SDSM) is used to track the SD reflectance degradation on orbit, by taking a ratio of the detector response when viewing the SD compared to the response when viewing the sun. The MODIS SDSMs have been operated both with and without the SDS in place. The SDSMs have also been operated in both a fixed and an alternating mode. In the alternating mode, the SDSM detectors view the SD, sun, and a dark background in an alternating pattern with the view changing on every MODIS scan within a single orbit. In the fixed mode, the SDSM detectors are fixed on the sun view for one orbit, and then are fixed on the SD view for the following orbit. This paper reviews the history of the SDSM operational configurations used throughout the MODIS missions and discusses the differences in the SD degradation results, which may be due to differences in sun-satellite geometry, SD signal level, and stray light effects. We highlight Aqua SDSM results from two recent dates in October 2017 and July 2019, where both the fixed and alternating mode calibrations were run on the same day, providing clear examples of the calibration differences. Additionally, we show how mixing the results from calibrations done with and without the SDS for Aqua MODIS can provide more stable results.

Twedt, Kevin A.↗

Status of the GSICS VIS/NIR DCC Calibration Efforts

This year's goals for the GSICS VIS/NIR group is to finalize the VIS/NIR demonstration product requirements and to process the product for public dissemination provided on the GSICS web page. The GSICS VIS/NIR group members have been working on a unified calibration approach among various agencies. Two calibration methods have been chosen for the visible bands, deep convective clouds (DCC) and lunar invariant targets. To come to consensus across the agencies, each step of the DCC process will be outlined. Brief discussions are to follow to determine any outstanding issues. The presentation will review the DCC calibration process implemented by the CERES calibration team. CERES has already implemented the DCC method across 18 geostationary satellites. The various agencies have taken the framework and optimized the method for their particular geostationary satellite. Several new improvements will be discussed, such as deseasonalization of the DCC reflectances, impact of the bidirectional model, and update frequency.

David Doelling↗

Use of an Internal Mercury-Argon Lamp for the Calibration of Raman Frequency in Large Raman Images of Astromaterials

Raman imaging is an emerging tool for the analysis of meteorites, as it is capable of describing the mineralogy and organics within a petrographic context. Adequately examining the heterogeneous composition of a meteorite often requires the collection of large Raman images with long collection times on the time-scale of days. However, the frequency calibration of the Raman instrument/spectrometer drifts on long timescales resulting in low frequency precision for the Raman spectra comprising a large Raman image. Here we utilize a Hg-Ar calibration lamp integrated into our Raman microscope to calibrate the Raman spectra within a Raman image. We characterize this method of calibration in detail.

Ryan S. Jakubek↗

Calibration of a V-Cone for Low Mass Flows For Small Core Compressor Research

Advancements in core compressor technologies are necessary for next generation, high Overall Pressure Ratio (OPR) turbofan engines. High pressure compressors (HPCs) for future engines are being designed with exit corrected mass flow rates less than 2.25 kg/s (5 lbm/s). In order to accurately measure the performance of these advanced designs, high accuracy measurements are needed in test facilities. The W7 High Speed Multistage Axial Compressor Facility at NASA Glenn Research Center has been used to acquire data for advanced compressor designs. This facility utilizes an advanced differential pressure flow meter called a V-Cone. The facility has historically tested components with physical mass flow rates in the range of 27 to 45 kg/s (60 to 100 lbm/s). As such, when the V-Cone was calibrated prior to installation, the calibrations focused on higher mass flow rates, and uncertainties in that regime range from 0.5% to 0.85%. However, for low mass flow rates under 9 kg/s (20 lbm/s), expected in tests of advanced high OPR HPCs rear stages, the uncertainties of the V-Cone exceed 2.5%. To address this, using a method similar to that utilized by the National Institute of Standards and Technology, an array of Critical Flow Venturi Nozzles (CFVs) was installed in the W7 test section and used to calibrate the V-Cone in 0.5 kg/s (1 lbm/s) increments up to 10.5 kg/s (23 lbm/s). This effort details the measurements and uncertainties associated with this calibration which resulted in a final uncertainty of the V-Cone measurements under 1%.

Measurement Uncertainty↗

Twenty Years of Terra MODIS Spectral Performance using the Spectro-Radiometric Calibration Assembly

The Moderate Resolution Imaging Spectroradiometer (MODIS) instrument on-board the Terra spacecraft has provided valuable Earth data to the science community for the last 20 years. Equipped with several on-board calibrators (OBCs), MODIS has continued to operate nominally since its launch in December 1999. The Spectro-Radiometric Calibration Assembly (SRCA) is one such OBC that is able to provide on-orbit measurements of the MODIS reflective solar bands (RSBs) in radiometric, spatial and spectral modes. While the SRCA is operating in spectral mode, it is able to monitor the center wavelength (CW), bandwidth (BW) and in-band relative spectral response (RSR) of most RSBs. Prelaunch measurements of the CWs, BWs and RSRs of the RSBs were performed at the system level using the Spectral measurement Assembly (SpMA). Using both the prelaunch measurements and the measurements obtained on-orbit using the SRCA, the changes in the spectral response of the MODIS reflective bands can be monitored throughout the mission. This paper will provide a brief description of the spectral calibration approach and report on-orbit changes in these spectral performance parameters and their uncertainties over the last 20 years. It will also address changes to the SRCA operation on-orbit and their impact on measured spectral calibration results. Despite two decades in orbit, the spectral responses for most Terra MODIS reflective bands continue to remain within their design specifications.

MODIS↗

SNPP VIIRS RSB on-orbit radiometric calibration algorithms Version 2.0 and the performances. Part I: The algorithms

The first VIIRS instrument is aboard the Suomi National Polar-orbiting Partnership satellite. The instrument has 14 reflective solar bands (RSBs) to passively collect photons reflected from the Earth surface in the design wavelengths from 412 to 2250 nm. The instrument uses a solar diffuser (SD) to radiometrically calibrate its RSBs. When lit by the Sun through an attenuation screen (the SD screen), the SD diffusely reflects off the incident sunlight to act as a radiance source for the calibration. An onboard solar diffuser stability monitor (SDSM) yields the on-orbit change of the SD bidirectional reflectance distribution function (BRDF) by comparing the signal strength from the SD with that from the Sun attenuated by another attenuation screen (the SDSM screen). Complications arise due to the discovery that the on-orbit change of the BRDF is angle dependent. Additionally, the SDSM does not cover the wavelengths for the short-wave infrared bands in the RSBs. Furthermore, satellite yaw maneuvers were performed in the early mission to yield data for refining the prelaunch SDSM screen relative effective transmittance and the relative product of the SD screen transmittance and the BRDF at the mission start. But the yaw maneuver data are coarse in the solar azimuth angles and thus are unable to yield accurate values between the measurement angles. Over the years of performing on-orbit radiometric calibration through the SD for the VIIRSRSBs, we have developed several highly effective calibration algorithms to address the issues mentioned above. This paper reviews these algorithms.

on-orbit cailbration↗

Wavelength Calibration of the Full-sun Ultraviolet Rocket SpecTrograph: (FURST)

The Sun has a well-known periodicity in sunspot number and magnetic field variation. The underlying cause of this 11-year cycle is not fully understood and has yet to be connected with those processes in other stellar objects. The Full-sun Ultraviolet Rocket SpecTrograph (FURST) is a sounding rocket payload being developed by Montana State University (MSU) alongside the Marshall Space Flight Center (MSFC) solar physics group. Scheduled to launch from White Sands Missile Range (WSMR) in 2022, this instrument is unique in that it will provide the connection between stellar observatories with measurements of our Sun. It will achieve this through extremely high-resolution full-disk spectroscopy in EUV. We aim to obtain a wavelength resolution R > 10,000 in the 115 - 181 nm range, on par with that of the Hubble (HST) Space Telescope Imaging Spectrograph (STIS). The Lyman Alpha line (121 nm) is known to oversaturate most CCD electronics and is of particular challenge for this spectral range. In addition, this resolution goal will allow us to study the 3 km/s motion (a Doppler-shift of about 0.01 Angstroms) of the relatively low-temperature plasma in the chromosphere and lower corona. This paper will present the results of our simulation of the diagnostic lamp signal to be used in this wavelength calibration. To test the viability of this precise of a device, we are building a collimator capable of calibrating the FURST instrument under these strict radiometric requirements. By way of a diagnostic lamp simulation, we will account for photon noise, CCD electronic readout noise, and statistical error. These will lead to the development of our pre- and post-launch calibration plan. Future work includes absolute radiometric and wavelength calibration with this new collimator. In addition, the ability of FURST to measure extremely small Doppler-shifts will provide capabilities for planetary atmospheric scientists. This impact is coupled with the diverse international partnership created by the closely-knit Sounding Rocket teams across the globe. These Sounding Rockets have an even broader impact, as they encourage future satellite missions under the prospect of long-term observations.

FURST↗

NASA Glenn Icing Research Tunnel: 2019 Cloud Calibration Procedure and Results

The NASA Glenn Research Center 2019 Icing Research Tunnel cloud calibration results are presented in this paper. The current status of the cloud uniformity, liquid water content, and drop-size calibration results will be discussed. The goals achieved in this calibration were to establish a uniform cloud and to generate transfer functions from the inputs of airspeed, spray bar atomizing air pressure, and spray bar water pressure to the outputs of median volumetric diameter (drop size distributions) and liquid water content. This was completed for both 14 CFR Parts 25 and 29, Appendix C (“typical” icing) and Appendix O (supercooled large drop) conditions. The cloud uniformity from the Standard nozzles has remained the same as what was reported for the 2014 full calibration. Changes were made to the Mod1 nozzle cloud, resulting in higher liquid water content values associated with the Mod1 cloud.

Emily N. Timko↗

SNPP VIIRS RSB on-orbit radiometric calibration algorithms Version 2.0 and the performances. Part I: The algorithms

The first VIIRS instrument is aboard the Suomi National Polar-orbiting Partnership satellite. The instrument has 14 reflective solar bands (RSBs) to passively collect photons reflected from the Earth surface in the design wavelengths from 412 to 2250 nm. The instrument uses a solar diffuser (SD) to radiometrically calibrate its RSBs. When lit by the Sun through an attenuation screen (the SD screen), the SD diffusely reflects off the incident sunlight to act as a radiance source for the calibration. An onboard solar diffuser stability monitor (SDSM) yields the on-orbit change of the SD bidirectional reflectance distribution function (BRDF) by comparing the signal strength from the SD with that from the Sun attenuated by another attenuation screen (the SDSM screen). Complications arise due to the discovery that the on-orbit change of the BRDF is angle dependent. Additionally, the SDSM does not cover the wavelengths for the short-wave infrared bands in the RSBs. Furthermore, satellite yaw maneuvers were performed in the early mission to yield data for refining the prelaunch SDSM screen relative effective transmittance and the relative product of the SD screen transmittance and the BRDF at the mission start. But the yaw maneuver data are coarse in the solar azimuth angles and thus are unable to yield accurate values between the measurement angles. Over the years of performing on-orbit radiometric calibration through the SD for the VIIRSRSBs, we have developed several highly effective calibration algorithms to address the issues mentioned above. This paper reviews these algorithms.

Ning Lei↗

Science camera calibration for extreme adaptive optics

The nascent field of planet detection has yielded a host of extra-solar planet detections. To date, these detections have been the result of indirect techniques: the planet is inferred by precisely measuring its effect on the host star. Direct observation of extra-solar planets remains a challenging yet compelling goal. In this vein, the Center for Adaptive Optics has proposed a ground-based, high-actuator density extreme A0 system (XAOPI), for a large (~10 m) telescope whose ultimate goal is to directly evidence a specific class of these objects: young and massive planets. Detailed system wave-front error budgets suggest that this system is a feasible, if not an ambitious, proposition. One key element in this error budget is the calibration and maintenance of the science camera wave front with respect to the wave-front sensor which currently as an allowable contribution of ~ 5 nanometers rms. This talk first summarizes the current status of calibration on existing ground-based A0 systems, the magnitude of this effect in the system error budget and current techniques for mitigation. Subsequently, we will explore the nature of this calibration error term, it's source in the non-commonality between the science camera and wave front sensor, and the effect of the temporal evolution of non-commonality. Finally, we will describe preliminary plans for sensing and controlling this error term. The sensing techniques include phase retrieval, phase contrast and external metrology. To conclude, a calibration scenario that meets the stringent requirement for XAOPI will be discussed.

MacIntosh, Bruce↗

Inflight Calibration of AVIRIS in 1992 and 1993

In order to pursue the quantitative research objective of AVIRIS, the spectral, radiometric characteristic of the sensor must be known at the time of flight data acquisition. AVIRIS is rigorously calibrated in the laboratory. In addition, three times each year these characteristics of AVIRIS are validated through an inflight calibration experiment. Absolute radiometric calibration and signal-to-noise results are present for the inflight calibration experiment orchestrated in 1992 and 1993.

Chrien, Tom↗

Using solar eclipse events to validate VIIRS reflective solar band calibration at multiple radiance levels

The VIIRS instruments aboard the SNPP and NOAA-20 (N20) satellites have 14 reflective solar bands (RSB) covering a spectral range from 412 nm to 2250 nm. The radiance of each VIIRS RSB is calculated from a quadratic function of the background-subtracted digital count, 𝑑𝑛, with the quadratic coefficients determined during pre-launch testing. On orbit, calibration is maintained using observations of a sunlit solar diffuser (SD), which views the Sun every orbit through a fixed attenuation screen. The SD observations, which are at nearly the same radiance level every orbit, provide a time varying overall calibration adjustment factor, the F-factor. But there is no designed on-orbit mechanism for calibration at multiple radiance levels, so the relative strengths of the quadratic coefficients continue to be fixed at the pre-launch values. On a few rare occasions, the VIIRS instruments have passed through a partial solar eclipse during the part of the satellite orbit when the SD is illuminated by the Sun (near the South Pole). As of August 2019, the SNPP and N20 VIIRS SDs have observed five and three partial solar eclipses, respectively. While these events are rare, they offer a unique opportunity to test the RSB calibration using the SD at different radiance levels. In this paper, we compare the reduction in the measured SD signals during an eclipse to the predicted radiance reduction based on the Sun-Moon geometry and a solar radiance model. We find good agreement between the data and model for all events, indicating that the VIIRS RSB gain linearity has remained fairly stable on-orbit. The most significant deviation is for the N20 short-wave infrared bands, which had non-linearity concerns during pre-launch testing. We also investigate the SNPP results using different versions of the prelaunch quadratic gain coefficients.

solar eclipse↗

Smart power supply calibration system

This paper details the development of an automated procedure to conduct calibrations of power supplies at Jet Propulsion Laboratory, California Institute of Technology (JPL). The fundamentals of power supply calibrations is given, and discussion on the method by which this custom software handles that calibration. Additionally, this technique provides real time uncertainty quantification of the calibrations. This automated system has demonstrated a time savings over existing automated techniques in use today.

Umansky, Brandon M.↗

Inter-Calibration of Nine UV Sensing Instruments Over Antarctica and Greenland Since 1980

Nadir-viewed intensities (radiances) from nine UV sensing satellite instruments are calibrated over the East Antarctic Plateau and Greenland during summer. The calibrated radiances from these UV instruments ultimately will provide a global long-term record of cloud trends and cloud response from ENSO events since 1980. We first remove the strong solar zenith angle dependence from the intensities using an empirical approach rather than a radiative trans-fer model. Then small multiplicative adjustments are made to these solar zenith angle normalized intensities in order to minimize differences when two or more instruments tempo-rally overlap. While the calibrated intensities show a negligible long-term trend over Antarctica and a statistically in-significant UV albedo trend of−0.05 % per decade over the interior of Greenland, there are small episodic reductions in intensities which are often seen by multiple instruments. Three of these darkening events are explained by boreal forest. Other events are caused by surface melting or volcanoes. We estimate a 2-sigma uncertainty of 0.35% for the calibrated radiances

Nadir-viewed intensities (radiances) from nine UV ↗