Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building energy efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Advanced co-simulation framework for assessing the interplay between occupant behaviors and demand flexibility in commercial buildings

With buildings contributing significantly to electricity usage, enabling demand flexibility becomes a challenge, especially when accounting for occupant comfort. This study introduces an innovative co-simulation framework integrating multiple models: heating, ventilation, and air conditioning (HVAC) system, building zone load, indoor airflow, supervisory control, and occupant comfort and behavior. Uniquely, this framework allows for a comprehensive and dynamic analysis of building systems and occupant interactions in demand response events. Using this framework, we conducted a case study using a typical small office building model. Specifically, we focused on three areas: (1) the impact of indoor airflow modeling on energy use, occupant comfort, and behaviors forecasting, (2) the impact of occupant behaviors on demand flexibility, and (3) occupant comfort and behaviors under demand response events. Key performance indicators such as energy use, flexibility factor, durations of occupant discomfort and occupant behaviors were analyzed. Our findings indicated variations in energy usage and occupant comfort within demand flexibility events, marked by uncertainty boundaries, with variability in demand shedding up to 57.9%. Here, we concluded that this framework is suitable for analyzing typical commercial buildings and their HVAC systems in terms of demand flexibility potential under the impact of occupant behaviors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

PETSc/TAO developments for GPU-based early exascale systems

The Portable Extensible Toolkit for Scientific Computation (PETSc) library provides scalable solvers for nonlinear time-dependent differential and algebraic equations and for numerical optimization via the Toolkit for Advanced Optimization (TAO). PETSc is used in dozens of scientific fields and is an important building block for many simulation codes. During the U.S. Department of Energy’s Exascale Computing Project, the PETSc team has made substantial efforts to enable efficient utilization of the massive fine-grain parallelism present within exascale compute nodes and to enable performance portability across exascale architectures. We recap some of the challenges that designers of numerical libraries face in such an endeavor, and then discuss the many developments we have made, which include the addition of new GPU backends, features supporting efficient on-device matrix assembly, better support for asynchronicity and GPU kernel concurrency, and new communication infrastructure. In conclusion, we evaluate the performance of these developments on some pre-exascale systems as well as the early exascale systems Frontier and Aurora, using compute kernel, communication layer, solver, and mini-application benchmark studies, and then close with a few observations drawn from our experiences on the tension between portable performance and other goals of numerical libraries.

Exascale Computing Project (ECP)↗

Stepping into the Midwest Bioeconomy: Stakeholder Engagement and Geospatial Tools to Assist in Perennial Bioenergy Crop Decision Making and Entrepreneurship

This project, “Ecosystem Services and Farm Entrepreneurship Technical Assistance,” was a three-year project originally planned for FY22–FY24. Due to a late start and a few extensions, it is being completed in early FY25. This project explored opportunities to support the deployment of a bioeconomy with a circular, more sustainable supply chain. Using a tool developed by Argonne to identify agricultural areas suitable for use in the bioeconomy, we sought to create opportunities in the bioeconomy as biomass producers, bioenergy users, and environmental entrepreneurs. We proposed to focus at the beginning on enhancing the tool’s capabilities, while engaging with key stakeholders to improve and expand the tool’s functionality for all potential stakeholders in the bioeconomy. We believe that expanding our tools and technologies, coupled with conversations in agricultural spaces, will be needed as we continue to explore how best to offer farmers whole-of supply-chain opportunities to participate in the bioeconomy. Through this project we have continued to gain a better understanding of the ways in which farmers, landowners, bioenergy users, and environmental entrepreneurs may approach the bioeconomy. In addition, as we improve our analytic toolkit, we can continue to refine our communication and the ways in which we can valuate the bioeconomy. Refining these tools allows us to dive deeper into conversations around plausible policies and drivers for future bioeconomy investment and engagement by stakeholders. By working with farmers and agricultural landowners to enable a sustainable bioeconomy business model, enhance their energy options, and recover resources from their waste streams, this project directly responds to the Bioenergy Technology Office’s (BETO) priorities of building a resilient energy economy. It addresses BETO’s focus on fostering the development and adoption of energy technologies that enable the conversion of waste to energy, efficient land use, and robust job creation. By establishing a technical assistance program that develops capabilities and practices in agricultural areas to implement a bioeconomy future, this program will develop an important linkage between technology being developed at U.S. Department of Energy national laboratories and the agricultural communities of the Midwest. This project focuses on farmers with lower productivity farmland. Because less productive lands create a more difficult revenue stream for conventional crops, these farmers may therefore be more open to alternative agricultural land management regimes. Consequently, the technical assistance program and the methodologies for targeting perennial bioenergy crop application on marginal land provide a distinct opportunity to engage with and invest in the bioeconomy in these economically stressed areas. Stakeholders in this project include farmers and landowners, local conservation organizations (NRCS, SWCS, etc.), universities, non-profit environmental and agricultural entities, farm consultants, environmental regulators, and industry, including the industries working on conversion technologies, anaerobic digestion, pyrolysis, and biochar generation, and the companies interested in trading or purchasing/supporting the valuation of ecosystem services (ES).

09 BIOMASS FUELS↗

Potential Cooling Energy Savings of Economizer Control and Artificial-Neural-Network-Based Air-Handling Unit Discharge Air Temperature Control for Commercial Building

Heating, ventilation, and air-conditioning (HVAC) systems play a significant role in building energy consumption, accounting for around 50% of total energy usage. As a result, it is essential to explore ways to conserve energy and improve HVAC system efficiency. One such solution is the use of economizer controls, which can reduce cooling energy consumption by using the free-cooling effect. However, there are various types of economizer controls available, and their effectiveness may vary depending on the specific climate conditions. To investigate the cooling energy-saving potential of economizer controls, this study employs a dry-bulb temperature-based economizer control approach. The dry-bulb temperature-based control strategy uses the outdoor air temperature as an indicator of whether free cooling can be used instead of mechanical cooling. This study also introduces an artificial neural network (ANN) prediction model to optimize the control of the HVAC system, which can lead to additional cooling energy savings. To develop the ANN prediction model, the EnergyPlus program is used for simulation modeling, and the Python programming language is employed for model development. The results show that implementing a temperature-based economizer control strategy can lead to a reduction of 7.6% in annual cooling energy consumption. Moreover, by employing an ANN-based optimal control of discharge air temperature in air-handling units, an additional 22.1% of cooling energy savings can be achieved. In conclusion, the findings of this study demonstrate that the implementation of economizer controls, especially the dry-bulb temperature-based approach, can be an effective strategy for reducing cooling energy consumption in HVAC systems. Additionally, using ANN prediction models to optimize HVAC system controls can further increase energy savings, resulting in improved energy efficiency and reduced operating costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Recent Experiences Calculating g-functions for Use in Simulation of Ground Heat Exchangers

Temperature response functions, known as g-functions, are a computationally efficient method for simulating ground heat exchangers (GHEs), used with ground-source heat pump (GSHP) systems, either as part of a whole-building energy simulation or as part of a dedicated ground heat exchanger design tool. In fact, at present, they are the only feasible way to simulate a ground-source heat pump system in a whole-building energy simulation. This paper summarizes recent developments in the field and recent experience using a new open-source g-function calculation tool known as pygfunction (Cimmino 2018a, 2018b). This experience includes accuracy, computation time, memory requirements and sensitivity to boundary conditions. With larger ground heat exchangers, e.g. in excess of 100 boreholes, the computational time and memory requirements can create challenges.

Spitler, Jeffery↗

Development of a Hybrid Single/Two-Phase Capillary-Based Micro-Cooler Using Copper Inverse Opals Wick with Silicon 3D Manifold for High-Heat-Flux Cooling Application: Preprint

Previously, two-phase capillary-based cooling from narrow (200-1,000 micrometer) heater-bridge copper inverse opal (CIO) wicks with heat flux levels exceeding 1,400 watts per square cm with a low superheat of approximately 10 degrees C was demonstrated. Here, we demonstrate the area scaling of the proposed technology to large-area micro-cooler for the high-heat-flux cooling of microprocessors and power electronics. We developed a hybrid single/two-phase micro-cooler that relies on capillary wicking in 25-micrometer-thick CIOs with an open channel silicon 3D-manifold for liquid delivery and vapor extraction, to achieve a high heat flux of approximately 400 watts per square cm over a heated area of 1 square cm. For the range of inlet water (21 degrees C water temperature) flowrates from 5 to 60 mL per min, we achieved total thermal resistances and vapor qualities of 0.68-0.2 square cm Kelvin per watt and 0.55-0.12, respectively. The high heat flux levels are achieved with flowrates that are 10 times smaller than conventional single- or two-phase microchannel cooling technology. The corresponding two-phase thermal resistances are in the range of 0.05 to 0.02 square cm Kelvin per watt with temperature superheat of 8 to 6 degrees C. While the overall performance of the large-area (10 by 10 square millimeter) capillary-based micro-cooler degraded compared to previous demonstration of the technology for a heated area of 5 by 5 square millimeter, preliminary computational fluid dynamics (CFD) modeling indicates that an improved manifold design will be able to achieve comparable performance.

capillary flow↗

Factors Influencing Grid-connected Heat Pump Water Heater Performance in the Southeast U.S.

Grid-connected heat pump water heaters (HPWH) can shift electrical load while minimizing impacts to hot water availability for occupants. This capability provides a flexible grid resource to utilities seeking to manage peak loads Such load control also can feasibly improve renewable utilization within the utility electric production mix, for instance using off-peak generation during periods with high renewable energy generation. It also offers lower electric bills to customers through increased energy efficiency of HPWH and cuts greenhouse gas emissions. In particular, the Southeast U.S. due to its high penetration of electric water heating presents a promising opportunity for grid-connected HPWHs. This paper builds upon the results of an extensive HPWH load shifting field study conducted in 51 occupied homes in Florida using EcoPort technology (Butzbaugh et al, 2022). In 2022, only an initial evaluation was available. Here, long term load results are available as well as examination of various control strategies and influences. Analysis is conducted for HPWH energy use and load shifting performance based on home occupancy (i.e., low and high) and water heater location (i.e., conditioned and unconditioned) across different temperature profiles. An unexpected outcome of this analysis was the poor performance of HPWHs located in conditioned spaces, possibly because of inadequate air volume from improper installation. We did find higher demand reductions from 2-hour load ups and slightly improved for critical peak signals in the afternoon control periods. As expected, higher occupancy households showed great load reductions.

Fenaughty, Karen↗

Marine Energy Environmental Toolkit for Permitting and Licensing

The permitting and licensing process for marine energy in the U.S. could take up to 7 years for even small demonstrations or pilot studies despite existing resources like Tethys, MarineCadstre, and the FERC E-Library. The goal of the Marine Energy Environmental Toolkit Project was to increase regulators, developers, and marine energy innovators’ understanding of potential environmental effects of marine energy conversion devices deployments and provide information to make efficient and effective determinations during permitting and licensing; develop a one-stop shop for existing environmental, spatial, regulatory, and scientific data that allows users to access disparate sources of data through a series of tags and spatial queries. The Toolkit (marineenergy.app) builds upon prior U.S. Department of Energy (DOE) Water Power Technologies Office (WPTO) investments by pulling from WPTO-funded and outside resources to facilitate the permitting and licensing process, inform technology developers of required permits, and disseminate the latest knowledge of the environmental effects of these devices to regulators, developers, and marine energy innovators and stakeholders.

16 TIDAL AND WAVE POWER↗

Multifamily Building Stock Modeling: Cooperative Research and Development Final Report, CRADA Number CRD-17-00701

U.S. multifamily buildings house 35 million households, consuming 4 quads of source energy and spending $48 billion on utility bills every year. Almost all of these households live in urban areas, where cities are taking the lead on setting aggressive energy goals. Cities currently do not have the data and tools necessary to identify and target opportunities to save energy in their building stock. Building on the open-source, OpenStudio-based ResStock platform, this project will extend the publicly-available ResStock modeling capabilities to the multifamily sector, enabling Radiant Labs, and others, to partner with cities to market and strategically deploy cost-effective, energy efficiency (EE) upgrades directly to high-priority households. Radiant Labs has been successful in using ResStock's single-family capabilities to provide value to the City of Boulder, Colorado. However, lack of multifamily capabilities in ResStock is a roadblock for Radiant Labs working with New York City, San Francisco, Washington, D.C., and other cities that have expressed significant interest in working with them. In addition, other cities, companies, and utilities can use these open-source capabilities to grow their EE portfolios, thereby multiplying the impact of this project. This work also enables national-scale analysis of EE potential in multifamily buildings, which is of strong interest to a variety of stakeholders, including the U.S. Department of Energy (DOE) Office of Energy Policy and Systems Analysis (EPSA), DOE Weatherization Assistance Program (WAP), U.S. Department of Housing and Urban Development (HUD), and the Bonneville Power Administration (BPA).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Higher Efficiency, Demand Flexible Refrigerator with On-Demand Micro-Vibrational De-icing Technology

Refrigerator technology has advanced significantly over the last couple of decades. Today’s refrigerators use only about 25% of the energy that was required to power models built in 1975. Even as they continually improve efficiency to meet standards, refrigerators have increased in size by almost 20%, added energy-consuming features such as through-the-door ice, and provide more benefits than ever before. However, a few challenges and technology gaps are preventing further improvement of the demand responsiveness and efficiency of the refrigerators. One of the major technology gaps in existing refrigerators is their outdated de-icing process. When the evaporator generates frost, an old-fashioned resistive heating element melts the ice. Most refrigerators have a timed defrost cycle, rather than an active system that could monitor the state of the frost. In these systems, not only is the precious electricity used at its least efficient form of conversion (direct conversion of electricity to heat), but also all the latent heat associated with the ice is wasted during the melting process. On top of that, the refrigerator needs to work harder to pull the temperature down after defrosting, and, last but not least, the food quality is severely impacted by the temperature swings during the defrost cycle. According to a study, the EU alone wastes 89 million tons of food in the supply chain every year. Any temperature swing during defrosting (about 6F according to Emerson for low-temperature cases) can negatively impact the shelf life of meat and other products for multiple days. All these issues can happen during the peak demand time of the electric grid. Unlike the conventional systems, the proposed novel advanced micro-vibrational deicing process uses no heat for defrosting. Instead, it uses the micro vibrations generated by a piezoelectric or vibration-generating module to mechanically break ice from the heat exchanger almost instantaneously. The project titled “Higher Efficiency, Demand Flexible Refrigerator with On-Demand Micro-Vibrational De-icing Technology, performed by Ultrasonic Technology Solutions, LLC (UTS) of Knoxville, TN, in collaboration with Emerson (now Copeland), represents the final phase of a multi-year effort funded under the U.S. Department of Energy’s Building Technologies Office (BTO) BENEFIT FOA 2020. Initiated on October 1, 2021, and completed after a nine-month no-cost extension ending September 30, 2025, this project aimed to develop and validate a novel micro-vibrational mechanical defrosting system, achieving more than 25% improvement in defrosting energy efficiency over conventional baseline defrosting technologies. Over sixteen quarters, the project advanced from fundamental ice-mechanical characterization and prototype development to full-scale system integration and validation. Initial efforts established project management infrastructure and characterized ice adhesion properties, followed by the design and fabrication of early aluminum-based prototypes for resonance frequency testing. Subsequent quarters saw rapid technical progression, including the identification of optimal piezoelectric and motor-based vibration mechanisms, the demonstration of effective de-icing over 6x6-inch aluminum surfaces. The team achieved its Go/No-Go milestone by exceeding the 25% energy-efficiency improvement target—reaching up to 3,340% under optimized conditions—and later confirmed that motor-driven systems offered superior performance and energy efficiency compared to piezoelectric alternatives. Continued refinement led to the development of amplifier systems on printed circuit boards, improved control and instrumentation hardware, and integration into full-scale heat exchanger (HX) prototypes at both UTS and Copeland facilities. Multiple vibration-mounting studies and frost-growth experiments guided mechanical optimization and noise-mitigation strategies, achieving a 17.5 dB reduction in sound pressure level and verifying robust mechanical performance. Advanced analyses, including modal and harmonic simulations, established a quantitative understanding of vibrational behavior and de-icing efficiency across >1000 cm² systems. The final project phase successfully demonstrated scalable integration within reach-in and chest freezer prototypes, confirmed >25% efficiency improvements in large-area systems, and completed a comprehensive business model and scale-up strategy identifying electric defrost systems as the primary beachhead market. The culmination of this DOE-supported effort establishes micro-vibrational defrosting as a viable, high-efficiency, low-noise, and demand-flexible de-icing technology, paving the way for commercial deployment and broader application in next-generation refrigeration systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Level Model Articulation with BuildingSync and OpenStudio

The use of the BuildingSync schema for describing the contents of buildings is becoming more common with its recent integration into the Audit Template tool as well as ASHRAE’s Building Energy Quotient (bEQ) web portal. Although BuildingSync was initially created to store and transfer data related to building energy audits (as defined by ASHRAE Standard 211), it has since been expanded to store the data needed to articulate fully defined physics-based building energy models. BuildingSync combined with abstracted high-level input methods defined in OpenStudio’s Standards project and the newly developed BuildingSync gem allows BuildingSync eXtensible Markup Language (XML) (Bray, Paoli, Sperberg-McQueen, Maler, Eve (Sun Microsystems, & Francois, 2008) document to be converted into OpenStudio models. Automatic generation of a building energy model from data collected during an audit 1) eliminates the need to separately generate an energy model, 2) improves consistency between model generation, and 3) simplifies evaluation of various energy efficiency measures. This manuscript will discuss this open-source project, including: development of the validation infrastructure necessary to provide formalized expectations of informational requirements for BuildingSync documents; development of the BuildingSync gem for translation of BuildingSync documents to OpenStudio models as well as example implementations; and finally, the manuscript will elaborate on the advantages and disadvantages of using high-level models generated from BuildingSync as surrogates to detailed models.

30 DIRECT ENERGY CONVERSION↗

Managing Army Plug Load Equipment Energy Use: Breakroom Appliances

Breakroom equipment is the third highest energy-consuming plug load category in Army buildings. In addition to the vending machine measures described separately, improved purchasing and control measures for breakroom appliances can save the Army more than 9 million kWh and $550K per year in the building types evaluated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhancing Operational Performance and Productivity Benefits in Breweries through Smart Manufacturing Technologies

This article uses case studies to demonstrate the potential of smart manufacturing (SM) and Internet of Things (IoT) technologies to enhance operational performance and productivity in industry. The analysis highlights benefits such as cost reduction, production flexibility, shorter product time-to-market, energy/water efficiency and environmental impact reduction, and increased productivity. To illustrate the effectiveness of SM and IoT approaches, the authors sought out manufacturers currently implementing or seeking to implement SM and IoT technologies. The authors identified beer brewing (NAICS Code 312120) as a rapidly expanding industry whose members appear eager to implement SM technologies to optimize production lines by revealing bottlenecks and identifying performance-reducing nodes. This article presents two case studies based on SM and IoT technologies in breweries. It briefly describes a systematic framework introduced elsewhere by the authors and uses it to assess the energy productivity and competitiveness of SM applications in breweries. This article addresses questions concerning the information and communications technology infrastructure needed to build smart breweries and how corporations simplify the installation and deployment of SM and IoT components. This article was originally published in the Proceedings of the 2019 ACEEE Summer Study on Energy Efficiency in Industry.

42 ENGINEERING↗

Assessment of Low-Cost Minisplit Heat Pump Connection System

This project was funded by SCE's Emerging Technologies Program, and evaluates the feasibility of a connection system that can pave the path to accelerated, cost-effective adoption of high-efficiency Minisplit Heat Pump (MSHP) systems. This report details the characterization of this connection system and a heat pump enabled with this technology in a laboratory setting, and assesses the energy and cost impact applicable to residential buildings in SCE service territory. The energy and economic analysis leverages NREL's ResStock TM modeling approach based on the EnergyPlus ® hourly simulation platform. The connection system can be incorporated into existing MSHP architectures. This reduces installation time from 10 to 20 man hours to approximately one hour or less, dramatically lowering total installation costs without adversely impacting heat pump performance. This report characterizes the connection system's leakage performance while connected and disconnected, as well as leakage over several connection/disconnection cycles, commensurate with manufacturer specifications for the individual components. The connector was incorporated into an off-the-shelf MSHP. Performance was compared to an identical unmodified heat pump. The connector had no impact on performance. Large-scale hourly energy simulations were performed for 22,574 homes across 15 counties in SCE service territory. The analysis was performed using baseline assumptions about the penetrations of window air conditioners (~18%) and six upgrade scenarios for these air conditioners. All scenarios assumed 100% adoption of the Connector-Supported Heat Pump (CSHP) in place of window air conditioners: MSHPs at Seasonal Energy Efficiency Ratio (SEER) 17, 25, and 33, and CSHPs at SEER 17, 25, and 33. Results show the increased adoption of high-efficiency heat pumps can result in up to 29% air conditioning energy savings for homes with window air conditioners.

42 ENGINEERING↗

Charting a Path for Research and Development of Reliability and Resilience in South Asia's Power Sector

The power sector in South Asia faces several trends with the potential to impact its reliability and resilience. Rapidly increasing demand, coupled with an increasing reliance on variable renewable resources and the circular linkages with climate change points to an increasing need to understand the extent of climate impacts on both the electricity load and the electricity generation. These larger shifts are also coupled with opportunities near the grid edge that could have a large impact on system planning and operations, such as electrification of the transport sector, increased reliance on buildings to serve a broader set of loads and be flexible resources for utilities, more efficient use of industrial and agricultural loads, and growth in distributed energy resources such as rooftop solar and batteries. It is critical that as this transformation takes place that expectations for reliability and resilience of the grid continue to increase in the region. The South Asia Group for Energy (SAGE), composed of USAID, the US Department of Energy, and three national laboratories, has been tasked with providing an overview of the research and development resources necessary to understand the upcoming challenges for the power system as it pertains to reliability and resilience. This discussion paper identifies some of the key trends and connections that are important for power sector reliability and resilience and provides a starting point for eliciting feedback from power sector stakeholders about their experiences and needs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Environmentally Robust Quantum Dot Down Converters for Highly Efficient Solid State Lighting

This project contributes fundamental understanding of the chemical synthesis of cadmium free quantum dots (QDs) designed for solid state lighting (SSL). Methods to incorporate gallium into quantum dot architectures were explored, which led to more stable and brighter solid state lighting devices. These findings will help advance the incorporation of quantum dots in highly energy efficient lighting devices with a warm color spectrum. Such Cd-free lighting devices can greatly accelerate the adoption of high efficiency, warm spectrum lighting in buildings. The project targeted InP/GaP/ZnS colloidal quantum dots that more effectively absorb the blue light produced by light emitting diode packages and emit monochromatic red light with near perfect efficiency. While significant improvements in the QD absorptivity were demonstrated, the absorbance increase achieved was 3x rather than the targeted 10x increase. Similarly, the luminescence from these QDs achieved about half of the target photoluminescence quantum yield (PLQY) and twice the desired spectral width, a measure of the color purity of their luminescence. While the target characteristics and some of the year 2/2 milestones were not met, the new QD architectures did lead to greater stability on SSL packages, a sign of the long term promise of the technology.

36 MATERIALS SCIENCE↗

Expanded Energy Credits in Energy Codes (Technical Brief)

This technical brief provides additional energy efficiency measures that go beyond the current prescriptive commercial energy codes. It demonstrates relative savings for multiple measures and shows a base cost effective package by building type and climate zone. An advanced savings package is also shown. Potential building savings for the base package for different building types across climate zones range from 3.9% to 22% of building energy cost, while the advanced package building savings range from 8.4% to 44%. In addition to measure descriptions, this technical brief includes code language that can be adopted by local jurisdictions to implement these measures for new buildings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Separate sensible and latent cooling: Carnot limits and system taxonomy

Energy efficiency and thermal comfort can be improved by independent control of temperature and humidity. In recent work, an emerging class of cooling systems known as separate sensible and latent cooling (SSLC) systems have demonstrated 14 to 47% energy savings, while simultaneously providing better comfort control than conventional air conditioning. In this work, SSLC is defined as using two or more cooling processes with unequal sensible heat ratio (SHR) to control temperature and humidity independently and dynamically. Fundamental efficiency limits of SSLC systems are developed for the first time, demonstrating that the Carnot efficiency for SSLC is higher than that of conventional systems. It is revealed that SSLC has particularly high potential for moderate outdoor temperatures, high sensible building loads, and drier indoor conditions. Additionally, this work proposes a classification scheme for SSLC systems, revealing an enormous number of feasible cycle permutations. This provides a framework for the important research task of developing SSLC systems that will save energy, be practical to construct, and be controllable.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗