Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ambient temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Evaluation program for secondary spacecraft cells. Initial evaluation tests of Eagle-Picher Industries, Incorporated 3.0 ampere-hour nickel-cadmium spacecraft cells

The capacity of the cells ranged from 3.58 to 3.97 amperehours during the three capacity tests. Three cells were removed from test, due to high pressure, during the C/10, 24-hour charge at room ambient temperature. The voltage requirement of 1.480 volts was exceeded by the cells during the C/10, 24-hour charge at 20 C, although the end-of-charge voltage was below this value (1.466-1.475 volts). Average capacity out during the 20 C charge efficiency test was 0.84 AH which represents 48% and is below the minimum requirement of 55%. The cells exhibited no pressure decay during the open-circuit stand portion of the pressure versus capacity test, as all cells reached their voltage limit (1.550 volts) before their pressure reached 20 psia with the highest pressure being 8 psia during charge.

Harkness, J. D.↗

The effect of water injection on nitric oxide emissions of a gas turbine combustor burning ASTM Jet-A fuel

Tests were conducted to determine the effect of water injection on oxides of nitrogen (NOx) emissions of a full annular, ram induction gas turbine combustor burning ASTM Jet-A fuel. The combustor was operated at conditions simulating sea-level takeoff and cruise conditions. Water at ambient temperature was injected into the combustor primary zone at water-fuel ratios up to 2. At an inlet-air temperature of 589 K (600 F) water injection decreased the NOx emission index at a constant exponential rate: NOx = NOx (o) e to the -15 W/F power (where W/F is the water-fuel ratio and NOx(o) indicates the value with no injection). The effect of increasing combustor inlet-air temperature was to decrease the effect of the water injection. Other operating variables such as pressure and reference Mach number did not appear to significantly affect the percent reduction in NOx. Smoke emissions were found to decrease with increasing water injection.

Marchionna, N. R.↗

Radioprotection in depressed metabolic states: The physiology of helium-cold hypothermia

The use of hypothermia as a means of radiation protection was studied on a variety of mammals exposed to 80% helium-20% oxygen atmospheres at low ambient temperatures. Results show that the LD for normothermic animals significantly increased compared with hypothermic animals; similar results were obtained for hibernating mammalians. Pre-exposure of animals to cold temperatures increased their ability to withstand radiation levels close to LD sub 50.

Musacchia, X. J.↗

Film cooling in a combustor operating at fuel-rich exit conditions

Data were taken with a film-cooled test plate placed in the exhaust stream of a rectangular combustor. Results showed that in a fuel-rich zone, fuel entrained into the film-cooling air would burn at the conditions tested. Test conditions were cooling-gas flow rates, 9.5 and 5 percent of total gas flow; cooling-gas velocities, 23 and 12 m/sec; ambient-temperature cooling gas; hot-gas velocity, nominally 215 m/sec; fuel-air ratio to stoichiometric fuel-air ratio values of 0.1, 0.8, 1.0, 1.2, and 1.35, resulting in hot-gas temperatures from 590 to 2100 K; and atmospheric pressure. Analytical prediction of wall temperatures agreed reasonably well with experimental results.

Tacina, R. R.↗

Jet noise from co-axial nozzles over a wide range of geometric and flow parameters

Free field pure jet noise data were taken for a large range of coaxial nozzle configurations. The core nozzles were circular (1 to 4 in. diameter) and plug types. The fan to core area ratio varied from 0.7 to 43.5, while the velocity ratio typically varied from 0 to 1. For most cases the two nozzles were coplanar but large axial extensions of either nozzle were also tested. Correlation of the data resulted in a simple procedure for estimating ambient temperature subsonic coaxial jet noise spectra over a wide range of geometric and flow parameters.

Olsen, W.↗

Pressure-loss and flow coefficients inside a chordwise-finned, impingement, convection, and film air-cooled turbine vane

Total-pressure-loss coefficients, flow discharge coefficients, and friction factors were determined experimentally for the various area and geometry changes and flow passages within an air-cooled turbine vane. The results are compared with those of others obtained on similar configurations, both actual and large models, of vane passages. The supply and exit air pressures were controlled and varied. The investigation was conducted with essentially ambient-temperature air and without external flow of air over the vane.

Hippensteele, S. A.↗

Role of physical properties of liquids in cavitation erosion

The dependence of erosion rates on the ambient temperature of water is discussed. The assumption that the gas inside the bubble is compressed adiabatically during collapse gives better agreement with experiments than the assumption that the gas is isothermally compressed. Acoustic impedance is an important liquid parameter that governs the erosion intensity in vibratory devices. The investigation reveals that the major physical properties of liquids governing the intensity of erosion include density, sound speed, surface tension, vapor pressure, gas content, and nuclei distribution.

Thiruvengadam, A.↗

Engineering information on an Analog Signal to Discrete Time Interval Converter (ASDT-IC)

An electronic control system for nondissipative dc power converters is presented which improves (1) the routinely attainable static output voltage accuracy to the order of + or - 1% for ambient temperatures from -55 to 100 C and (2) the dynamic stability by utilizing approximately one tenth of the feedback gain needed otherwise. Performance is due to a functional philosophy of deterministic pulse modulation based on pulse area control and to an autocompensated signal processing principle. The system can be implemented with commercially available unselected components.

Schwarz, F. C.↗

Development and demonstration of flueric sounding rocket motor ignition

An analytical and experimental program is described which established a flueric rocket motor ignition system concept incorporating a pneumatic match with a simple hand pump as the only energy source. An evaluation was made of this concept to determine the margins of the operating range and capabilities of every component of the system. This evaluation included a determination of power supply requirements, ignitor geometry and alinement, ignitor/propellant interfacing and materials and the effects of ambient temperatures and pressure. It was demonstrated that an operator using a simple hand pump for 30 seconds could ignite BKNO3 at a standoff distance of 100 m (330 ft) with the only connection to the ignitor being a piece of plastic pneumatic tubing.

Marchese, V. P.↗

Infrared telescopes for a space observatory

A cryogenically cooled infrared telescope of 1 to 2 meter aperture is discussed. Advantages of the space environment are detailed, and design considerations for cooled telescopes are given, leading to a schematic and preliminary design of a telescope for the space shuttle. The advantages of the sortie mode to an infrared observatory are dealt with and possible use of an ambient temperature telescope is discussed. Costs of infrared telescope observation are indicated.

Witteborn, F. S.↗

Two-position dc pulse voltage stabilizer

The advantages of the dc pulse voltage stabilizers over the continuous action stabilizers are described. These advantages include higher efficiency, low sensitivity to the ambient temperature and insignificant size and weight. A comparison is made between the schematics of the known two position pulse stabilizer with a Schmitt trigger and that developed by the author. A characteristic feature of the improved system is the increased stabilization coefficient and the possibility of smooth regulation of the output voltage. A practical schematic is presented for the improved two position pulse stabilizer along with its parameters.

Osadchiy, V. I.↗

A mercury flow meter for ion thruster testing

The theory of operation of the thermal flow meter is presented, and a theoretical model is used to determine design parameters for a device capable of measuring mercury flows in the range of 0 to 5 gm/hr. Flow meter construction is described. Tests performed using a positive displacement mercury pump as well as those performed with the device in the feed line of an operating thruster are discussed. A flow meter response time of about a minute and a sensitivity of about 10 mv/gm/hr are demonstrated. Additional work to relieve a sensitivity of the device to variations in ambient temperature is indicated to improve its quantitative performance.

Wilbur, P. J.↗

Evaluation of several additional dry lubricants for spacecraft applications

Four transfer-film ball-bearing retainer materials were evaluated for their lubricating ability and wear capability under conditions of 120-gram radial load, 450-gram axial load, 3600-rpm unidirectional rotation, 23 C ambient temperature, and less than .1 microtorr pressure, using R-2 sized unshielded ball bearings. The 'stop-test' criterion was a total of one billion revolutions or a torque buildup greater than 18 gm-cm per bearing pair. A PTFE-fiberglass-MoS2 composite, a PTFE-bronze composite, and a tantalum-molybdenum-MoS2 composite operated for one billion revolutions without reaching the 18-gram torque limit. A p-oxybenzoyl polymer-MoS2 composite operated sixteen million revolutions before reaching the 18-gm cm stop-test torque. The first three materials are considered as suitable lubricants under the test conditions employed.

Vest, C. E.↗

NaK-nitrogen liquid metal MHD converter tests at 30 kw

The feasibility of electrical power generation with an ambient temperature liquid-metal MHD separator cycle is demonstrated by tests in which a NaK-nitrogen LM-MHD converter was operated at nozzle inlet pressures ranging from 100 to 165 N/sq cm, NaK flow rates from 46 to 72 kg/sec, and nitrogen flow rates from 2.4 to 3.8 kg/sec. The generator was operated as an eight-phase linear induction generator, with two of the eight phases providing magnetic field compensation to minimized electrical end losses at the generator channel inlet and exit.

Cerini, D. J.↗

Jet noise from coaxial nozzles over a wide range of geometric and flow parameters

Free field pure jet noise data were taken for a large range of coaxial nozzle configurations. The core nozzles were circular (1 to 4 in. diam.) and plug types. The fan to core area ratio varied from 0.7 to 43.5, while the velocity ratio typically varied from 0 to 1. For most cases the two nozzles were coplanar but large axial extensions of either nozzle were also tested. Correlation of the data resulted in a simple procedure for estimating ambient temperature subsonic coaxial jet noise spectra over a wide range of geometric and flow parameters.

Olsen, W.↗

Noise tests of a high-aspect-ratio slot nozzle with various V-gutter target thrust reversers

The results of experiments on the noise generated by a 1.33 x 91.4 cm slot nozzle with various V-gutter reversers are presented. The experiments were conducted with near-ambient temperature jets at nozzle pressure ratios of 1.25 to 3.0, yielding jet velocities of about 190 to 400 m/sec. At pressure ratios of 2 or less, the reversers, in addition to being noisier than the nozzle alone, also had a more uniform directional distribution and more high-frequency noise. At pressure ratios above 2, the nozzle alone generated enough shock noise that the levels were about the same as for the reversers. The maximum overall sound pressure level and the effective overall sound power level both varied with the sixth power of jet velocity over the range tested.

Stone, J. R.↗

Biological modulation of the earth's atmosphere

Review of the evidence that the earth's atmosphere is regulated by life on the surface so that the probability of growth of the entire biosphere is maximized. Acidity, gas composition including oxygen level, and ambient temperature are enormously important determinants for the distribution of life. The earth's atmosphere deviates greatly from that of the other terrestrial planets in particular with respect to acidity, composition, redox potential and temperature history as predicted from solar luminosity. These deviations from predicted steady state conditions have apparently persisted over millions of years. These anomalies may be evidence for a complex planet-wide homeostasis that is the product of natural selection. Possible homeostatic mechanisms that may be further investigated by both theoretical and experimental methods are suggested.

Margulis, L.↗

The resistance of selected high strength alloys to embrittlement by a hydrogen environment

Selected high strength iron base and cobalt base alloys with yield strengths in the range from 1233 to 2129 MN per sq m (179 to 309 KSI) were resistant to degradation of mechanical properties in a one atmosphere hydrogen environment at ambient temperature. These alloys were strengthened initially by cold working which produced strain induced epsilon prime-hcp martensite and fcc mechanical twins in an fcc matrix. Heat treatment of the cobalt base alloy after cold working produced carbide precipitates with retention of an hcp epsilon phase which increased the yield strength level to a maximum of 2129 MN per sq m (309 KSI). High-strength alloys can be produced which have some resistance to degradation of mechanical properties by a hydrogen environment under certain conditions.

Benson, R. B., Jr.↗