Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “additional protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

A Distributed Approach to High-Rate Delay Tolerant Networking Within a Virtualized Environment

The High-Rate Delay Tolerant Networking (HDTN) project has taken a distributed service-based approach to the development of a highly efficient delay tolerant networking (DTN) implementation. Through the analysis of many DTN implementations, system and mission requirements as well as the DTN protocol specifications, HDTN has worked to infuse modern computing technologies into the NASA approach to interplanetary networking. The initial use case of the HDTN software runs on a hypervisor representative of the International Space Station (ISS) DTN Gateway. In this scenario, multiple emulated payloads will send science data through HDTN to a mission operations center. HDTN will provide store and forward capability as well as network flow management. This paper discusses the infusion path of cognitive networking technologies in the NASA SCaN networks using the DTN architecture and protocols as the basis for cognitive routing and network management capabilities. HDTN has been developing the Bundle Protocol encoding and decoding mechanisms and messaging framework that can be used as the basis for integrating DTN with various learning and decision-making processes. The concepts of distributed computing, network virtualization, software defined networking and delay tolerant networking are basic building blocks which will further the development of cognitive networking. In addition to discussion of the HDTN software development and testing, this paper examines the role that each of these technologies play in the evolution of the current state of space networking into an intelligent network of networks.

Delay Tolerant Networking↗

A Distributed Approach to High-Rate Delay Tolerant Networking Within a Virtualized Environment

The High-Rate Delay Tolerant Networking (HDTN) project has taken a distributed service-based approach to the development of a highly efficient delay tolerant networking (DTN) implementation. Through the analysis of many DTN implementations, system and mission requirements as well as the DTN protocol specifications, HDTN has worked to infuse modern computing technologies into the NASA approach to interplanetary networking. The initial use case of the HDTN software runs on a hypervisor representative of the International Space Station (ISS) DTN Gateway. In this scenario, multiple emulated payloads will send science data through HDTN to a mission operations center. HDTN will provide store and forward capability as well as network flow management. This paper discusses the infusion path of cognitive networking technologies in the NASA Space Communications and Navigation (SCaN) networks using the DTN architecture and protocols as the basis for cognitive routing and network management capabilities. HDTN has been developing the Bundle Protocol encoding and decoding mechanisms and messaging framework that can be used as the basis for integrating DTN with various learning and decision-making processes. The concepts of distributed computing, network virtualization, software defined networking and delay tolerant networking are basic building blocks which will further the development of cognitive networking. In addition to discussion of the HDTN software development and testing, this paper examines the role that each of these technologies play in the evolution of the current state of space networking into an intelligent network of networks.

Rachel Mary Dudukovich↗

THE ABSORPTION OF HYDROGEN ON LOW PRESSURE HYDRIDE MATERIALS

For this study, hydrogen getter materials (Zircaloy-4 and pure zirconium) that have a high affinity for hydrogen (and low overpressure) have been investigated to determine the hydrogen equilibrium pressure on Zircaloy-4 and pure zirconium. These materials, as with most getter materials, offered significant challenges to overcome given the low hydrogen equilibrium pressure for the temperature range of interest. Hydrogen-zirconium data exists for pure zirconium at 500 C and the corresponding hydrogen overpressure is roughly 0.01 torr. This manuscript presents the results of the equilibrium pressures for the absorption and desorption of hydrogen on zirconium materials at temperatures ranging from 400 C to 600 C. The equilibrium pressures in this temperature region range from 150 mtorr at 600 C to less than 0.1 mtorr at 400 C. It has been shown that the Zircaloy-4 and zirconium samples are extremely prone to surface oxidation prior to and during heating. This oxidation precludes the hydrogen uptake, and therefore samples must be heated under a minimum vacuum of 5 x 10{sup -6} torr. In addition, the Zircaloy-4 samples should be heated at a sufficiently low rate to maintain the system pressure below 0.5 mtorr since an increase in pressure above 0.5 mtorr could possibly hinder the H{sub 2} absorption kinetics due to surface contamination. The results of this study and the details of the testing protocol will be discussed.

08 HYDROGEN↗

Sprites and State Channels: Payment Networks that Go Faster than Lightning

Bitcoin, Ethereum and other blockchain-based cryptocurrencies, as deployed today, cannot scale for wide-spread use. A leading approach for cryptocurrency scaling is a smart contract mechanism called a payment channel which enables two mutually distrustful parties to transact efficiently (and only requires a single transaction in the blockchain to set-up). Payment channels can be linked together to form a payment network, such that payments between any two parties can (usually) be routed through the network along a path that connects them. Crucially, both parties can transact without trusting hops along the route. In this paper, we propose a novel variant of payment channels, called Sprites, that reduces the worst-case “collateral cost” that each hop along the route may incur. The benefits of Sprites are two-fold. 1) In Lightning Network, a payment across a path of ℓ channels requires locking up collateral for Θ(ℓΔ) time, where Δ is the time to commit an on-chain transaction. Sprites reduces this cost to Θ(ℓ+Δ). 2) Unlike prior work, Sprites supports partial withdrawals and deposits, during which the channel can continue to operate without interruption. In evaluating Sprites we make several additional contributions. First, our simulation-based security model is the first formalism to model timing guarantees in payment channels. Our construction is also modular, making use of a generic abstraction from folklore, called the “state channel,” which we are the first to formalize. We also provide a simulation framework for payment network protocols, which we use to confirm that the Sprites construction mitigates against throughput-reducing attacks.

97 MATHEMATICS AND COMPUTING↗

Novel data analysis method for obtaining better performance from a complex 3D-printed collimator

Additively manufactured scattered beam collimators are increasingly being employed to boost the sample to cell peak signal ratio in high pressure neutron diffraction studies because of manufacturing versatility and performance improvements. We study how the measured diffraction pattern is affected by the presence of a collimator downstream of the sample, and develop a novel protocol that provides more effective background rejection. This protocol takes into account critical performance-determinants that were identified in this study, namely: (i) effectively identifying the collimator pattern on the detector; (ii) understanding the dependence of this pattern on sample and cell composition; and (iii) accurately identifying and differentiating the different regions of the pattern on the detector based on the dependency of the cell or sample and finally (iv) resolving the intensities at regions of the detector where neutrons scattered from the sample are preferentially represented, in order to boost the sample to cell peak signal ratio. Application of this novel analysis protocol is shown to increase the collimator performance over the traditional method.

3D printing↗

Uncovering Hidden Entanglement in Twin Beams

Proper characterization of quantum correlations in multimode optical quantum states is critical for applications in quantum information science. However, standard entanglement measurements can lead to incomplete state reconstruction and characterization. Here, we implement a resonator-based detection system that reveals entanglement between sideband modes of twin beams, achieving full tomography and retrieving often ignored quantum correlations. Unlike standard spectral measurements such as homodyne detection, resonator detection can independently address the sidebands of each beam, thereby accessing these hidden correlations. Additionally, we show how phase shifts between the carrier and the sideband modes of the involved fields redistribute information and modify the observation of entanglement for different witnesses. The ability of the resonant detection to independently address sideband modes of entangled states can contribute to enhancing the capacity for secure communication and quantum networking protocols.

Rincon Celis, Raul [University of Sao Paulo, Brazi↗

Generation of scalable genuine multipartite Gaussian entanglement with a parametric amplifier network

Genuine multipartite entanglement is a valuable resource in quantum information science, as it exhibits inseparability across all possible bipartitions of a multimode quantum state. The large degree of quantum correlations can be exploited in various quantum information protocols, such as teleportation, dense coding, and quantum interferometry. Here, in this study, we propose a scheme to generate scalable genuine multipartite continuous-variable entangled states of light using a parametric amplifier network. We verify the presence of genuine quadripartite, hexapartite, and octapartite entanglement through a violation of the positive partial transpose criteria. Additionally, we use 𝛼-entanglement of formation to demonstrate the scalability of our approach to an arbitrary number of 2⁢𝑁 genuinely entangled parties by taking advantage of the symmetries present in our scheme.

Kim, Saesun [Univ. of Oklahoma, Norman, OK (United↗

Systematic measurements of whole-body imaging dose distributions in image-guided radiation therapy

Purpose: The full benefit of the increased precision of contemporary treatment techniques can only be exploited if the accuracy of the patient positioning is guaranteed. Therefore, more and more imaging modalities are used in the process of the patient setup in clinical routine of radiation therapy. The improved accuracy in patient positioning, however, results in additional dose contributions to the integral patient dose. To quantify this, absorbed dose measurements from typical imaging procedures involved in an image-guided radiation therapy treatment were measured in an anthropomorphic phantom for a complete course of treatment. The experimental setup, including the measurement positions in the phantom, was exactly the same as in a preceding study of radiotherapy stray dose measurements. This allows a direct combination of imaging dose distributions with the therapy dose distribution. Methods: Individually calibrated thermoluminescent dosimeters were used to measure absorbed dose in an anthropomorphic phantom at 184 locations. The dose distributions from imaging devices used with treatment machines from the manufacturers Accuray, Elekta, Siemens, and Varian and from computed tomography scanners from GE Healthcare were determined and the resulting effective dose was calculated. The list of investigated imaging techniques consisted of cone beam computed tomography (kilo- and megavoltage), megavoltage fan beam computed tomography, kilo- and megavoltage planar imaging, planning computed tomography with and without gating methods and planar scout views. Results: A conventional 3D planning CT resulted in an effective dose additional to the treatment stray dose of less than 1 mSv outside of the treated volume, whereas a 4D planning CT resulted in a 10 times larger dose. For a daily setup of the patient with two planar kilovoltage images or with a fan beam CT at the TomoTherapy unit, an additional effective dose outside of the treated volume of less than 0.4 mSv and 1.4 mSv was measured, respectively. Using kilovoltage or megavoltage radiation to obtain cone beam computed tomography scans led to an additional dose of 8-46 mSv. For treatment verification images performed once per week using double exposure technique, an additional effective dose of up to 18 mSv was measured. Conclusions: Daily setup imaging using kilovoltage planar images or TomoTherapy megavoltage fan beam CT imaging can be used as a standard procedure in clinical routine. Daily kilovoltage and megavoltage cone beam computed tomography setup imaging should be applied on an individual or indication based protocol. Depending on the imaging scheme applied, image-guided radiation therapy can be administered without increasing the dose outside of the treated volume compared to therapies without image guidance.

60 APPLIED LIFE SCIENCES↗

SU-F-J-178: A Computer Simulation Model Observer for Task-Based Image Quality Assessment in Radiation Therapy

Purpose: Traditionally, image quality in radiation therapy is assessed subjectively or by utilizing physically-based metrics. Some model observers exist for task-based medical image quality assessment, but almost exclusively for diagnostic imaging tasks. As opposed to disease diagnosis, the task for image observers in radiation therapy is to utilize the available images to design and deliver a radiation dose which maximizes patient disease control while minimizing normal tissue damage. The purpose of this study was to design and implement a new computer simulation model observer to enable task-based image quality assessment in radiation therapy. Methods: A modular computer simulation framework was developed to resemble the radiotherapy observer by simulating an end-to-end radiation therapy treatment. Given images and the ground-truth organ boundaries from a numerical phantom as inputs, the framework simulates an external beam radiation therapy treatment and quantifies patient treatment outcomes using the previously defined therapeutic operating characteristic (TOC) curve. As a preliminary demonstration, TOC curves were calculated for various CT acquisition and reconstruction parameters, with the goal of assessing and optimizing simulation CT image quality for radiation therapy. Sources of randomness and bias within the system were analyzed. Results: The relationship between CT imaging dose and patient treatment outcome was objectively quantified in terms of a singular value, the area under the TOC (AUTOC) curve. The AUTOC decreases more rapidly for low-dose imaging protocols. AUTOC variation introduced by the dose optimization algorithm was approximately 0.02%, at the 95% confidence interval. Conclusion: A model observer has been developed and implemented to assess image quality based on radiation therapy treatment efficacy. It enables objective determination of appropriate imaging parameter values (e.g. imaging dose). Framework flexibility allows for incorporation of additional modules to include any aspect of the treatment process, and therefore has great potential for both assessment and optimization within radiation therapy.

60 APPLIED LIFE SCIENCES↗

Stochastic Petri net analysis of a replicated file system

A stochastic Petri-net model of a replicated file system is presented for a distributed environment where replicated files reside on different hosts and a voting algorithm is used to maintain consistency. Witnesses, which simply record the status of the file but contain no data, can be used in addition to or in place of files to reduce overhead. A model sufficiently detailed to include file status (current or out-of-date), as well as failure and repair of hosts where copies or witnesses reside, is presented. The number of copies and witnesses is a parameter of the model. Two different majority protocols are examined, one where a majority of all copies and witnesses is necessary to form a quorum, and the other where only a majority of the copies and witnesses on operational hosts is needed. The latter, known as adaptive voting, is shown to increase file availability in most cases.

Bechta Dugan, Joanne↗

Implementing bright light treatment for MSFC payload operations shiftworkers

Intense light can phase-shift circadian rhythms and improve performance, sleep, and wellbeing during shiftwork simulations, but to date there have been very few attempts to administer light treatment to real shiftworkers. We have developed procedures for implementing light treatment and have conducted controlled trials of light treatment for MSFC Payload Operations staff during the USML-1 mission. We found that treatment had beneficial effects on fatigue, alertness, self-rated job performance, sleep, mood, and work attendance. Although there are portable bright light boxes commercially available, there is no testing protocol and little performance information available. We measure the illuminance of two candidate boxes for use in this study and found that levels were consistently lower than those advertised by manufacturers. A device was developed to enhance the illuminance output of such units. This device increased the illuminance by at least 60 % and provided additional improvements in visual comfort and overall exposure. Both the design of this device and some suggested procedures for evaluating light devices are presented.

Hayes, Benita C.↗

Space Communications and Navigation (SCaN) Network Simulation Tool Development and Its Use Cases

In this work, we focus on the development of a simulation tool to assist in analysis of current and future (proposed) network architectures for NASA. Specifically, the Space Communications and Navigation (SCaN) Network is being architected as an integrated set of new assets and a federation of upgraded legacy systems. The SCaN architecture for the initial missions for returning humans to the moon and beyond will include the Space Network (SN) and the Near-Earth Network (NEN). In addition to SCaN, the initial mission scenario involves a Crew Exploration Vehicle (CEV), the International Space Station (ISS) and NASA Integrated Services Network (NISN). We call the tool being developed the SCaN Network Integration and Engineering (SCaN NI&E) Simulator. The intended uses of such a simulator are: (1) to characterize performance of particular protocols and configurations in mission planning phases; (2) to optimize system configurations by testing a larger parameter space than may be feasible in either production networks or an emulated environment; (3) to test solutions in order to find issues/risks before committing more significant resources needed to produce real hardware or flight software systems. We describe two use cases of the tool: (1) standalone simulation of CEV to ISS baseline scenario to determine network performance, (2) participation in Distributed Simulation Integration Laboratory (DSIL) tests to perform function testing and verify interface and interoperability of geographically dispersed simulations/emulations.

Jennings, Esther↗

Medical Data Architecture (MDA) Project Status

The Medical Data Architecture (MDA) project supports the Exploration Medical Capability (ExMC) risk to minimize or reduce the risk of adverse health outcomes and decrements in performance due to in-flight medical capabilities on human exploration missions. To mitigate this risk, the ExMC MDA project addresses the technical limitations identified in ExMC Gap Med 07: We do not have the capability to comprehensively process medically-relevant information to support medical operations during exploration missions. This gap identifies that the current in-flight medical data management includes a combination of data collection and distribution methods that are minimally integrated with on-board medical devices and systems. Furthermore, there are a variety of data sources and methods of data collection. For an exploration mission, the seamless management of such data will enable a more medically autonomous crew than the current paradigm. The medical system requirements are being developed in parallel with the exploration mission architecture and vehicle design. ExMC has recognized that in order to make informed decisions about a medical data architecture framework, current methods for medical data management must not only be understood, but an architecture must also be identified that provides the crew with actionable insight to medical conditions. This medical data architecture will provide the necessary functionality to address the challenges of executing a self-contained medical system that approaches crew health care delivery without assistance from ground support. Hence, the products supported by current prototype development will directly inform exploration medical system requirements.In fiscal year 2018, the MDA project developed Test Bed 2, the second iteration in a series of prototypes with functionality focused on data security through role-based access control and encryption, integration with One Portal exercise software and ingestion of an ultrasound Digital Imaging and Communications in Medicine (DICOM) file and image display. Test Bed 2 advances the medical data system architecture framework by providing these functionalities in a scalable system that maintained a layered, modular design. The architecture framework uses a data services approach with role-based access to data in a customized medical record system suitable for space exploration. These functionalities were demonstrated as part of the Next Space Technologies for Exploration Partnerships (NextSTEP) ground test demonstrated at the NASA Johnson Space Center Integrated Power, Avionics and Software (iPAS) facility. Interfacing to a Core Flight Software (CFS) system, the MDA system, using Consultative Committee for Space Data Systems (CCSDS) protocol, transferred an exercise file from the simulated flight MDA system to a mirrored MDA system on the ground through the CFS system. The selection of data sources and demonstrations enabled the team to address stakeholder concerns throughout the development process. In the next iteration, the MDA team will work with stakeholders to identify additional relevant functionalities to further advance system data models, standards and principles that will inform the medical system requirements development.

medical data architecture↗

Venous Gas Embolism: Review to Quantify a Safe Volume of Air in Intravenous Fluids Bags for Spaceflight Applications

INTRODUCTION: The ability to create intravenous fluids (IVF) in-situ from the potable water supply of a spaceflight vehicle or habitat is a desired capability for an exploration medical system. In order to define an acceptable volume of air in IVF bags, an understanding of the volume of venous gas embolism as it relates to negative outcomes is needed. The purpose of this study is to review the literature to determine if there is a known volume of gas that contributes to mortality and/or morbidity that could be used to define requirements for rapid IVF infusion in microgravity. METHODS: A literature review was conducted of the PubMed database using the syntax: (Venous) AND (Gas OR Air) AND (Embolism) AND (Morbidity) AND (Mortality) AND (Volume) as well as manual review of references from relevant articles. 151 articles were screened excluding partial text and pediatric articles. Studies were reviewed for identification of volume of venous gas embolism associated with morbidity and/or mortality, which identified 27 articles. RESULTS: Reviewed literature included animal studies, case reports, and review articles. A high variation of proposed volumes contributing to mortality was reported. The limited human data values ranged from 20 ml to 200 ml of infused air with mortality estimated to be 48 – 80%. No studies evaluated human morbidity in any capacity. DISCUSSION: The lack of consensus on the safe volume of infused air has potential ramifications for IVF use in spaceflight as current technologies to create IVF from potable water may introduce air in IVF bags. While current microgravity infusion protocols call for the use of inline air removal filters, commercially available options have flow rate limitations that preclude rapid infusion in a resuscitation scenario. Such filters may be used in parallel to increase flow rate, but the time required to set up such a system may exclude its use during a medical emergency. Additionally, these consumable filters drive up the overall mass and volume of the medical system. Identification of a safe volume of air in IVF would allow for guidelines for the in-situ production of IVF in future spaceflight vehicles/habitats.

Christopher R Woodard↗

Open-source Wireless Sensor Network (Wi-Se Net) for Flexible Deployment

Wireless sensors, especially if battery powered, have a number of advantages over wired sensors for flexible or temporary diagnostic deployment in a field or lab setting. Recent advances in wireless technology and microprocessor boards have produced a variety of inexpensive off-the shelf chips which can communicate wirelessly with simple protocols. This paper describes the design and implementation of a highly customizable wireless sensor network (called Wi-Se Net) using inexpensive open-source hardware components as wireless nodes. These wireless sensor nodes can transmit data at a rate <250 Hz, can be battery powered, and have a small footprint (2x5 cm). In addition, a preliminary over-the-air programming system was developed to allow for simple wireless configuration when active. The network performance was demonstrated by taking distributed and electrically isolated temperature measurements on a high-voltage lab apparatus. Although this test case is in a laboratory setting, this network architecture could be easily repurposed for various other forms of monitoring.

Wireless Sensor Network↗

Additional value of systolic wall thickening in myocardial stunning evaluated by stress-rest gated perfusion SPECT

Aim and patients: The aim of the present study is to evaluate the additional value of systolic wall thickening to myocardial perfusion in diagnosing myocardial stunning in patients with angiography proven coronary artery disease. We selected 91 ischemic patients (82 males; mean age 59.7 ± 10.3) with CAD documented by angiography. Ischemia was defined as a summed difference score ≥5. All patients underwent a 2-day gated perfusion SPECT protocol. The patients received a dose of 740 MBq of {sup 99m}Tc-tetrofosmin after stress and at rest. Treadmill maximal exercise tests were performed on all patients. Results: The post-stress LVEF was significantly lower than rest LVEF (48.1% ± 10.3% vs 50.3% ± 10.7%; P = .0001). The wall thickening summed difference score was 4.44 ± 4.13 (P = .0001). At a multivariate regression analysis, only WT-SDS as independent variable was significantly correlated with myocardial ischemia (SDS). We also divided patients according to SDS in those with mild (SDS < 8) and severe (SDS ≥ 8) ischemia. WT-SDS, but not ∆LVEF, was significantly different between groups. Conclusions: WT-SDS, more than the depression in the global function (∆LVEF) of the left ventricle, correlates with the degree of ischemia and better identifies, when present, the stunning phenomenon.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Commissioning of the discrete spot scanning proton beam delivery system at University of Texas M.D. Anderson Cancer Center, Proton Therapy Center, Houston

Purpose: To describe a summary of the clinical commissioning of the discrete spot scanning proton beam at the Proton Therapy Center, Houston (PTC-H). Methods: Discrete spot scanning system is composed of a delivery system (Hitachi ProBeat), an electronic medical record (Mosaiq V 1.5), and a treatment planning system (TPS) (Eclipse V 8.1). Discrete proton pencil beams (spots) are used to deposit dose spot by spot and layer by layer for the proton distal ranges spanning from 4.0 to 30.6 g/cm{sup 2} and over a maximum scan area at the isocenter of 30x30 cm{sup 2}. An arbitrarily chosen reference calibration condition has been selected to define the monitor units (MUs). Using radiochromic film and ion chambers, the authors have measured spot positions, the spot sizes in air, depth dose curves, and profiles for proton beams with various energies in water, and studied the linearity of the dose monitors. In addition to dosimetric measurements and TPS modeling, significant efforts were spent in testing information flow and recovery of the delivery system from treatment interruptions. Results: The main dose monitors have been adjusted such that a specific amount of charge is collected in the monitor chamber corresponding to a single MU, following the IAEA TRS 398 protocol under a specific reference condition. The dose monitor calibration method is based on the absolute dose per MU, which is equivalent to the absolute dose per particle, the approach used by other scanning beam institutions. The full width at half maximum for the spot size in air varies from approximately 1.2 cm for 221.8 MeV to 3.4 cm for 72.5 MeV. The measured versus requested 90% depth dose in water agrees to within 1 mm over ranges of 4.0-30.6 cm. The beam delivery interlocks perform as expected, guarantying the safe and accurate delivery of the planned dose. Conclusions: The dosimetric parameters of the discrete spot scanning proton beam have been measured as part of the clinical commissioning program, and the machine is found to function in a safe manner, making it suitable for patient treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality Assurance Framework for Mini-Grids

Providing clean and affordable energy services to the more than 1 billion people globally who lack access to electricity is a critical driver for poverty reduction, economic development, improved health, and social outcomes. More than 84% of populations without electricity are located in rural areas where traditional grid extension may not be cost-effective; therefore, distributed energy solutions such as mini-grids are critical. To address some of the root challenges of providing safe, quality, and financially viable mini-grid power systems to remote customers, the U.S. Department of Energy (DOE) teamed with the National Renewable Energy Laboratory (NREL) to develop a Quality Assurance Framework (QAF) for isolated mini-grids. The QAF for mini-grids aims to address some root challenges of providing safe, quality, and affordable power to remote customers via financially viable mini-grids through two key components: (1) Levels of service: Defines a standard set of tiers of end-user service and links them to technical parameters of power quality, power availability, and power reliability. These levels of service span the entire energy ladder, from basic energy service to high-quality, high-reliability, and high-availability service (often considered 'grid parity'); (2) Accountability and performance reporting framework: Provides a clear process of validating power delivery by providing trusted information to customers, funders, and/or regulators. The performance reporting protocol can also serve as a robust monitoring and evaluation tool for mini-grid operators and funding organizations. The QAF will provide a flexible alternative to rigid top-down standards for mini-grids in energy access contexts, outlining tiers of end-user service and linking them to relevant technical parameters. In addition, data generated through implementation of the QAF will provide the foundation for comparisons across projects, assessment of impacts, and greater confidence that will drive investment and scale-up in this sector. The QAF implementation process also defines a set of implementation guidelines that help the deployment of mini-grids on a regional or national scale, helping to insure successful rapid deployment of these relatively new remote energy options. Note that the QAF is technology agnostic, addressing both alternating current (AC) and direct current (DC) mini-grids, and is also applicable to renewable, fossil-fuel, and hybrid systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗