TPSAS-NF1676L-10819-DND

Additional aerodynamic data for the benchmark configuration of partially-dressed cavity-closed nose landing gear (PDCC-NLG), obtained at a flow Mach number of 0.166, are provided in this presentation. A detailed account of the unsteady surface pressure fluctuations acquired with a Kulite transducer designed to be mobile is also given. The roving nature of the transducer allowed the sensor to be placed at numerous locations where high-amplitude pressure fluctuations are expected. The measured surface pressure spectra are mainly broadband in nature, lacking any local peaks associated with coherent vortex shedding. This finding is in agreement with off-surface flow measurements based on particle image velocimetry, which revealed the flow field to be a collection of separated shear layers without any dominant vortex shedding processes.

Mehdi R Khorrami↗

TPSAS-NF1676L-10756-DND

Additional aerodynamic data for the benchmark configuration of partially-dressed cavity-closed nose landing gear (PDCC-NLG), obtained at a flow Mach number of 0.166, are provided in this presentation. A detailed account of the unsteady surface pressure fluctuations acquired with a Kulite transducer designed to be mobile is also given. The roving nature of the transducer allowed the sensor to be placed at numerous locations where high-amplitude pressure fluctuations are expected. The measured surface pressure spectra are mainly broadband in nature, lacking any local peaks associated with coherent vortex shedding. This finding is in agreement with off-surface flow measurements based on particle image velocimetry, which revealed the flow field to be a collection of separated shear layers without any dominant vortex shedding processes.

Mehdi R Khorrami↗

Coherence Analysis of the Space Launch System using Unsteady Pressure Sensitive Paint

Transonic buffet during atmospheric ascent is a major source of unsteady loading on launch vehicles that, in the past, has led to structural failures. Thus, determining accurate buffet forcing functions (BFFs) to properly predict the vehicle response to buffet is of vital importance in launch vehicle design. The state of the art for obtaining the BFFs relies on wind-tunnel tests where the fluctuating pressures are measured by pressure transducers (PTs) at sparse locations on a rigid, geometrically-scaled buffet model. To compute the BFFs, the outer mold line (OML) of the vehicle is mapped onto contiguous panels centered at the location of the PTs and the measured fluctuating pressures are integrated over the panels’ areas. To mitigate conservatism due to the assumption that the measured buffet pressures act in phase across each panel, coherence factors are applied, effectively reducing the integration areas and, therefore, the buffet forces. For coherence factors to provide the proper level of BFF attenuation, accurate knowledge of the spatial and temporal correlation of the buffet pressures is paramount. Unfortunately, even with hundreds of unsteady pressure transducers instrumenting the models, compromises must be made on the spatial resolution of the PTs. Typically, the PT layout aims at resolving the pressure correlation along the longitudinal axis of the vehicle, assuming that coherent structures propagate mostly in the longitudinal direction. As a result, the distribution of azimuthal/cross-stream correlation is not well known and its impact on the estimated BFFs is often neglected. To fill this and other knowledge gaps, extremely high spatial-resolution uPSP data were collected for three different production-design configurations of the Space Launch System in the NASA Ames Research Center Unitary Plan Wind Tunnel 11-Foot Transonic Wind Tunnel. Specifically, two cargo configurations, the Block 1 and Block 1B, and one crew configuration, the Block 1B crew, were surveyed at resolutions ranging from 600,000 to over 1 million uPSP measurement locations. To shed light on the temporal and spectral behavior of are presented. Several OML regions and flow features of interest are investigated, from theexpansion/shock on the Orion Multi-Purpose Crew Vehicle, to the terminal shock environment on the core stage, and the Strouhal shedding behind the boosters forward attach. The sensitivity of these environments to the vehicle attitude is examined. Furthermore, for selected panels,coherence factors that accurately capture the azimuthal coherence distribution of the buffetpressures are derived and their impact on the estimated BFFs is discussed. Finally, distributions of the local convection velocity and cross spectrum phase are presented.

buffet↗

Development and Testing of Pulse Guns for Combustion Instability Testing

To test liquid rocket engines (LREs) for combustion instabilities, devices such as bombs are often used to create pressure wave disturbances. Bombs, while effective, are inherently dangerous, expensive, and difficult to procure. Over the years, pulse guns have been used as a safer and more cost-effective way to generate controlled pressure disturbances in engine chambers. In anticipation of the need for stability testing of prototype LREs at NASA Marshall Space Flight Center (MSFC), a set of pulse guns have been designed, fabricated, tested, and characterized. The pulse gun program is funded by the RS-25 Engine Program managed out of MSFC and funded by NASA’s Space Launch System (SLS) through the MSFC Liquid Engines Office (LEO). A pulse gun is a simple device – like a traditional gun, it has a breech and barrel section. However, unlike a traditional gun, there is no bullet, as the purpose of the pulse gun is strictly to fire a high pressure pulse. Instead of a firing pin and primer that would normally be used in a traditional gun, an initiator is used to activate the gun powder. The initiator is a highly reliable pyrotechnic initiator. For this study, clone versions of the NASA Standard Initiator (NSI) were used. The initiator is used to ignite a pre-measured amount of gun powder loaded into the breech. When the pressure of the burnt gun powder exceeds the set point of a downstream burst disk, the disk ruptures, allowing the high pressure pulse to travel downstream through the barrel section. A ballistic pressure transducer located in the breech section is used to measure the short duration, high pressure pulse. Some configurations of the pulse gun have barrel sections that include one or more additional ballistic pressure transducers. These additional pressure measurements help track the degradation and damping of the pulse as it travels out of the barrel section. The measurements may also be used to determine the velocity of pulse. The objective of this paper is to present the different variants of this newly-developed pulse gun and characterize performance over a range of parameters. The parameters include breech diameter, barrel length, amount of gun powder used, the way the gun powder is packed, and the pressure setting of the burst disk. There are a total of six pulse guns: three with the 0.25 inch breech and three different length barrels, and three with the 0.40 inch breech and three different length barrels. For both breech sizes, the associated barrels are referred to as standard, one-port, and two-port barrels. The standard barrel has no instrumentation and is likely the barrel that will be used for engine stability testing. The one- and two-port barrels were designed specifically for pulse gun component testing to allow measurements of the magnitude and timing of the high pressure pulse as it makes its way through the pulse gun. The burst disks tested were commercially-available burst disks designed to rupture at 8,000, 16,000, and 24,000 psid. Testing was accomplished by firing the pulse gun into a test chamber pressurized with nitrogen at about 2300 psig. A total of four Model 113B23 High frequency ICP® pressure sensors (10k psi) were mounted in the test chamber, in the same plane as the pulse gun. Two of the sensors had “trimmed” adapters, and two did not. Given the symmetrical configuration of the sensors within the test chamber, different amplitudes of pressure measurements are attributed to the use of trimmed versus untrimmed adapters. The untrimmed adapters, with their narrower passages, tended to amplify the pressure amplitudes by as much as 50%. In total, 41 pulse gun tests have been conducted.Data are still being analyzed, but some trends are apparent. For example, measurements taken within the pulse gun are shown in Figures 3 and 4 for Hot-fires (HFs) # 11 and 39, respectively. Both tests were identical in that the 0.40 inch ID breech, two-port barrel, 8,000 psid burst disk, and same amount of gunpowder (6.639 grains for HF# 11, and 6.576 grains for HF# 39) were used, and the back pressure in the nitrogen test chamber was ~2300 psig. Despite keeping all these variables constant, the results from these two tests look quite different. For both tests, the first pressure peak shown in the P2111 trace within the breech is the firing of the initiator. The second peak and any subsequent peaks are from the combustion of the gunpowder. It should be noted that because the sensors are dynamic, the ~2300 psig baseline static pressure is not shown in the figures. For HF# 11, the burst disk clearly ruptured in a little over 0.1 ms from the time the initiator was fired. This is evident from the abrupt rise in pressure for P2112 followed by another abrupt rise in pressure for P2113. The sensors track the movement of the high pressure pulse through the pulse gun. For HF# 39, however, there was nearly 1 ms delay between the initiator firing and the burst disk rupturing. The only difference between these two tests was the way in which the gunpowder was packed within the breech. For HF# 11, the gunpowder was poured directly into the breech, atop the initiator, and held in place with a vegetable fiber wad appropriately sized for the barrel diameter. Once in place, the wad firmly held the gunpowder in place. For HF# 39, the gunpowder was rolled within cigarette paper with the ends of the paper twisted. The rolled gunpowder was gently pushed down into the breech, toward the initiator, and no wad was used. This method of loading the gunpowder consistently produced longer delays in the rupture of the burst disk, presumably because there was a steady, fuller burning of the gunpowder. The burst disk was rated for 8,000 psid, which means that the burst disk should not have opened until the pressure in the breech reached ~10,300 since there was ~2300 psig back pressure in the test chamber. In the case of HF# 11, the breech pressure only reached roughly 4200 psi before there was leakage either through or past the burst disk, but for HF#39, the breech pressure reached 10,600 psi prior to the burst disk opening. The temperature of the burst disk is certainly a factor in determining when the burst disk will rupture. A sharp rise in the burst disk temperature could weaken it and cause it to stray from the designed set point burst pressure. The burst disks are manufactured of Inconel to try to reduce their sensitivity to temperature, but how the burst disks perform above 900°F is not documented. All burst disks were engineered and tested by the manufacturer for ambient temperature conditions. One theory for why rolling the gunpowder in cigarette paper may produce better results is related to a more controlled temperature environment. The cigarette paper may act as a sheath that protects the burst disk from excessive temperatures during the rapid buildup of pressure in the breech. The ultimate benefit of not breeching the burst disk prematurely is shown in Figures 5 and 6, which graphs the resultant pressure pulse produced in the test chamber. For HF #11, the peak pressure on the P2123 trimmed adapter is about 270 psi, while for HF# 39 it is 343 psi, which is about 1.27 times greater in magnitude. In either case, the pressure pulse is ~20 μs in width once it reaches the test chamber. Another pressure rise about 100 μs later can be seen on the sensors located across from the pulse gun port, P2124 and P2121. These pressures are lower due to attenuation of the pressure wave as it moves across the test chamber. After the wave encounters the wall, it reflects back and forth within the chamber until it completely dissipates.

Pulse Gun↗

Overview of the Dragonfly Entry Aerosciences Measurements (DrEAM) Suite

NASA Ames and Langley arepartnering with DLR to propose acomprehensive instrumentation suite known as the Dragonfly Entry Aerosciences Meas-urements (DrEAM). DrEAM being the first competed mission to fly EDL instrumentation as part of NASA’s Engineering Science Investigation (ESI).DrEAM will provide key aerothermodynamicdata and performance analysisfor Dragonfly’s forebody and backshell therma lprotection system (TPS),and also includes a DLR-provided Data Acquisition System(DAS).Titan’s atmosphere predominantly consists of nitro-gen (~98% by mole) with small amounts of methane(~2% by mole)and other trace gases. CN is a strong ra-diator and is found in nonequilibriumconcentrationsfor Titan entry. The accurate modeling of nonequilibrium CN radiation has proven to be a difficult task. Prompted by the Huygensmission, many experimental campaigns and analyses were performed to better understand the aerothermal environments experience by the probe dur-ing Titan entry[1].However, the Huygens probe carried no heatshieldinstrumentation. Therefore,the DrEAM instrumentation suite will significantly advance the state-of-the-art not only by documenting theenviron-ment and performance of Dragonfly’sentry system but also by making keymeasurements in Titan’s atmos-phere for thefirst time, thus providing new benchmark dataapplicable to entry science more generally. Current Measurement Goals: Aerothermal envi-ronments and TPS responsewill be measured using sen-sors similarto the Mars Entry, Descent, and Landing In-strumentation2 (MEDLI2) Integrated Sensor Plug(MISP) and the COMbined Aerothermaland Radiome-ter Sensor (COMARS)suite[2], with the latter supplied by DLR.For MEDLI2, MISP usedembedded thermo-couples (TCs) todirectly measure in-depth temperature of theTPS at several locations,which can also be used to infer surface environmentsvia inverse analysis. For DrEAM, the MISPstyle plugswill be known as Drag-onfly Sensors for Aero-Thermal Reconstruction (Drag-STR)plugs. On Schiaparelli, the COMARSsuite in-cludedthree total surface-mounted heatflux sensors, three pressure sensors, and one radiometer. For DrEAM, the COMARS package will be known as COmbined Sensor System for Titan Atmosphere (COSSTA). Atmospheric density measurements and capsuleaerodynamic data will be obtained throughthe onboard Inertial Measurement Unit (IMU),supple-mented by pressure transducers similar tothose used by the MEDLI Mars Entry AtmosphericData System (MEADS).The DrEAM pressure sensors will be known as Dragonfly Atmospheric Flight Transducers(DrAFT) Both DragSTR and DrAFThave flight heritagefrom MISP and MEADS on the MSLand Mars 2020mis-sions, and the COMARS suite successfullyflew on the ESA Schiaparelli EDMlander. A preliminary layout of the sensors is shown in Fig. 1. Because Dragonflyuses the same aeroshell provider (i.e., LockheedMartin) and materials for the TPS,with what are expected to be sim-ilar thicknesses as MSL and Mars 2020on both the heat shield and backshell, theDrEAMinstrumentation will look to utilize the same techniques and processes as de-veloped byMEDLI and MEDLI2for vehicle integra-tion. This commonality alsoenables DrEAMto lever-age the extensiveground test qualifications performed forMEDLI and MEDLI2 and claim substantial heritagefor this system.

A Brandis↗

Overview of Dragonfly Entry Aerosciences Measurements (DrEAM)

NASA Ames Research Center (ARC) leads the Dragonfly Entry Aerosciences Measurements (DrEAM) project, which is an aeroshell instrumentation suite on the Dragonfly mission that fulfills the Engineering Science Investigation requirement for the New Frontiers mission. NASA ARC is partnering with NASA Langley Research Center (LaRC) and the German Aerospace Center (DLR) to provide a comprehensive sensor suite, including a DLR-provided Data Acquisition System (DAS). DrEAM will provide key aerothermodynamic data and performance analysis for Dragonfly’s forebody and backshell Thermal Protection System (TPS). Titan’s atmosphere predominantly consists of ni-trogen (~98% by mole) with small amounts of me-thane (~2% by mole) and other trace gases. CN is a strong radiator, and is found in nonequilibrium con-centrations for Titan entry. The accurate modeling of nonequilibrium CN radiation has proven to be a diffi-cult task. Prompted by the Huygens mission, many experimental campaigns and analyses were performed to better understand the aerothermal environments experienced by the probe during Titan entry [1]. How-ever, the Huygens probe carried no heatshield instru-mentation. Therefore, the DrEAM sensor suite will sig-nificantly advance the state-of-the-art not only by documenting the environment and performance of Dragonfly’s entry system but also by making key in situ measurements in Titan’s atmosphere for the first time. Aerothermal environments and TPS response will be measured using sensors whose flight heritage is tak-en from the Mars Entry, Descent, and Landing In-strumentation 2 (MEDLI2) thermocouple plugs and the COMbined Aerothermal and Radiometer Sensor (COMARS) suite [2], with the latter supplied by DLR. The MEDLI2 project used embedded thermocouples to directly measure the in-depth TPS temperature-time history at several locations on the heat shield and backshell of the Mars 2020 entry vehicle. These tem-perature measurements, in turn, can be used to infer surface environments via an inverse analysis proce-dure analogous to that used for MEDLI. For DrEAM, the thermocouple plug subsystem will be known as Dragonfly Sensors for Aero-Thermal Reconstruction (DragSTR). On Schiaparelli, the COMARS suite in-cluded three total surface-mounted heat flux sensors, three pressure sensors, and one radiometer. For DrEAM, the COMARS package will be known as the COmbined Sensor System for Titan Atmosphere (COSSTA). Since the methane concentration in the Titan atmos-phere is directly proportional to the radiative heat flux, the COSSTA measurements will be used to reduce the current uncertainty in the methane volume fraction. Atmospheric density measurements and capsule aero-dynamic data will be obtained through the onboard Inertial Measurement Unit (IMU), supplemented by pressure transducers similar to those used by the MEDLI and MEDLI2 projects. The DrEAM pressure sensors will be known as the Dragonfly Atmospheric Flight Transducers. (DrAFT). The pressure measure-ments, when combined with data from the on-board IMU, will allow for reconstruction of such quantities as vehicle Mach number, freestream density, and atmos-pheric winds. DrAFT measurements will enhance Dragonfly trajectory reconstruction and enable a sepa-ration of the aerodynamics from the atmosphere, as was done for MEDLI [3] and is currently in process for the MEDLI2 flight data set.

EDL↗

Unsteady Pressure Acquisition on the 1.75% Scale SLS Block 1B Cargo Liftoff Configuration

Time-varying pressure on the core of the Space Launch System (SLS) Block 1B Cargo vehicle was acquired using instrumentation typically used for steady, time averaged pressure. Resono Pressure Systems, Inc. in partnership with the University of Wyoming have developed a unique hardware and software system for measuring unsteady pressure, which was implemented in a large-scale wind tunnel test through a nonreimbursable Space Act Agreement with NASA. The technique was applied to 12 pressure ports on the 1.75% scale SLS wind tunnel model. Tubing lengths of approximately 14 inches separated the pressure transducer module from the pressure taps on the model surface, and surface-mount validation sensors (Kulites) were installed in close proximity to 5 of the 12 pressure ports. Up to about 500 Hz, the frequency response of pressure fluctuations agreed to within 1 dB of amplitude and 10° of phase difference compared to the simultaneously-acquired surface-mount transducers. Sample results using the reconstructed pressure from the full azimuthal ring of taps are presented.

unsteady pressure↗

Evaluating the Utility of Pressure Scanners for Unsteady Pressure Measurements in Wind Tunnel Characterization of the Space Launch System

In many aerodynamic measurement applications, the ability to make time-accurate measurements with pressure scanners provides practical advantages over making the same measurements directly using flush-mounted transducers. The pneumatic distortion due to the tubing between the sensing module and surface port limits the usefulness of such measurements to averaged, steady data only. This issue has restricted the application of pressure scanners for unsteady pressure measurements in wind tunnel and flight-testing applications. The Wiener-filtered inverse system response model has been proven to be effective in reconstructing complex unsteady pressure signals acquired remotely using pressure scanners. In this work, the feasibility of using pressure scanning systems for time-resolved pressure measurements in the NASA Langley 14- by 22-Foot Subsonic Wind Tunnel was evaluated. Results demonstrated good agreement between the reference transducers and reconstructed pressure scanner measurements up to frequencies of approximately 500 Hz.

Unsteady pressure↗

Joint Acceptance Attenuation Factor of Integrated Pressure with Unsteady Pressure-Sensitive Paint Measurements

The Unsteady Pressure-Sensitive Paint (uPSP) is widely used to measure the surface pressure of the scaled model in the wind tunnel tests. Compared to the conventional pressure transducers, uPSP has the advantage of high spatial resolution. With multiple high-speed cameras, the uPSP data collected with the camera pixels are mapped to the surface grid of the scaled model and converted to pressure. The shot noise, which is associated with the quantum processes both in the generation of the photons by the luminescent uPSP and in the conversion of the photons into electrons within the camera, is the dominant component of the noise in the uPSP measurement. The integrated pressure is usually computed as an area-weighted average of the uPSP measured pressures on the grid nodes of a user-defined patch. The effect of the shot noise is reduced in the integrated pressure; however, the measurement of the aerodynamic pressure is also attenuated. This paper discusses the Joint Acceptance Attenuation Factor (JAAF) of the integrated pressure with uPSP measurements. The JAAF is defined as the ratio of the auto or cross Power Spectral Density (PSD) of the integrated aerodynamic pressure on the patch to the average auto PSD of the aerodynamic pressure on the grid nodes of the patch. Under the assumption that the cross spectrum of the aerodynamic pressure can be described with the Corcos model, the closed-form formula of the JAAF is derived for the integrated pressure on rectangular patches via the summation of uPSP measurements on discrete grid nodes. The closed-form formula is verified via the integration of the pressure field of Corcos model over continuous areas. The properties of the JAAF with different parameters are presented and the applications in the comparison of the spectrum of the pressure transducers and uPSP measurements, which were collected in the NASA Space Launch System (SLS) tests with the 11-by-11-foot transonic wind tunnel at NASA Ames Research Center in December 2017 and September 2019 respectively, are also discussed. The work described in this paper is a part of NASA’s development of a new state-of-the-art uPSP capability in production wind tunnels. Funding was provided by the NASA Aerosciences Evaluation and Test Capabilities(AETC) Portfolio Office.

Unsteady Pressure-Sensitive Paint↗

Novel Mars In-situ Wind & Wind-Blown Particle Measurement Instruments

Mars Sonic Anemometer We have developed the Mars Sonic Anemometer: an in-situ wind measuring instrument. It uses transducers to transmit ‘chirps’ through a volume of atmosphere and measures wind direction, speed, and temperature based on the chirp travel times when received by a paired transducer (fig 1). This method can rapidly take multiple samples of wind (~20 Hz) and can measure gentler wind speeds (~0.05 m/s) than current planetary weather stations (~1Hz and ~2m/s) and is more durable than recent Mars wind sensors. The Sonic Anemometer opens new avenues of research into Mars surface-to-atmosphere exchange (e.g., of heat, momentum or trace gases). It also can be recast as a hydrogen ortho-para sensor for a giant planet descent probe or as an infrasound detector for Earth or Venus. The performance of the sensor at Mars-like conditions of 6mbar of CO2 was validated at the Danish Mars Wind Tunnel.

Donald J Banfield↗

Unsteady Surface Pressure Characterization on Launch Vehicle in Liftoff Configuration

Acquisition of unsteady pressure using remote scanners can provide practical advantages over making the same measurements directly using flush-mounted pressure transducers. However, pneumatic distortion of the signal is introduced by the tubing between the sensing module and surface port. This typically limits the usefulness of such measurements to averaged, steady data only, restricting the application of pressure scanners for unsteady pressure measurements in the wind tunnel and flight-testing applications. In this work, unsteady pressure on the surface of a 1.75%-scale model of the NASA Space Launch System Block 1B Cargo vehicle was remotely measured at the NASA Langley Research Center 14- by 22-Foot Subsonic Tunnel using an ESP pressure scanner. Subsequent reconstruction using an empirically-tuned, Wiener-filtered inverse transfer function produced excellent agreement compared to nearby surface-mounted transducers within a usable bandwidth of approximately 500 Hz. Interactions between the launch vehicle and the support tower produced strong oscillations that were absent in the vehicle-alone configuration, and it is likely that the wake interaction leads to a resonant flow response when the launch tower is immediately downstream of the vehicle.

Unsteady pressure↗

Force Measurement for Wind Tunnel Facilities - Current Practices and Research Investments

This presentation will provide an introduction to strain gage balances (force transducers) used in NASA’s wind tunnel facilities. It will cover the breadth of wind tunnel applications using balances ranging from cryogenic facilities to facilities with aero heating affects. Specific areas of expertise including six-component balance design and calibration will also be discussed. Moreover, research areas including additive manufacturing of wind tunnel balances, the development of topology optimization tools to produce novel force transducer geometries, and dynamic force measurement will also be highlighted.

Wind tunnel balance↗

Sound-masking device for a roll-up door

A portable sound-masking device for placing on a roll-up door having a number of horizontally-extending elements. The sound-masking device has a fixture, a magnet, and a transducer. The fixture has an inner face, an outer face, and a pair of spaced-apart tabs protruding from the inner face, the tabs being configured to engage one of the horizontally-extending elements of the roll-up door. The magnet is fastened to the inner face of the fixture and provides a force that tethers the sound-masking device to the roll-up door. The transducer is fastened to the outer face and is configured to emit sound-masking noise.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Detection, monitoring, and determination of location of changes in metallic structures using multimode acoustic signals

Methods for detection, monitoring, and determination of location of changes in rigid structures with arbitrarily complex geometries are described. Implementations include locating acoustic transducers that generate and receive acoustic signals at multiple locations along a surface of the rigid structure, wherein longitudinal spacing between the transducer locations define measurement zones. Acoustic signals with chosen amplitude-time-frequency characteristics excite multiple vibration modes in the structure within each zone. Small mechanical changes in the inspection zones lead to scattering and attenuation of broadband acoustic signals, which are detectable as changes in received signal characteristics as part of a through-transmission technique. Additional use of short, narrowband pulse acoustic signals as part of a pulse-echo technique allows determination of the relative location of the mechanical change within each zone based on the differential delay profiles.

42 ENGINEERING↗

Hybrid semiconductor-piezoacoustic radiofrequency device

An amplifying radiofrequency device includes a piezoelectric film and a semiconductor amplifier layer. The piezoelectric film is conformed as an acoustic waveguide. The piezoelectric film has a principal acoustic propagation direction parallel to the principal conduction direction of the amplifier layer. Interdigitated transducers are positioned on the piezoelectric film to respectively launch an acoustic wave in response to an input RF signal, and transduce the acoustic wave back to an output RF signal. There is a distance of less than the acoustic wavelength between the semiconductor amplifier layer and the piezoelectric film. The piezoelectric film has a thickness of less than the acoustic wavelength. According to a method for making such a device, a stack of III-V layers is epitaxially grown on a III-V substrate, wherein the stack comprises a first etch stop layer, a second etch stop layer, an amplifier layer, and a contact layer. The stack is bonded to a lithium niobate film. The III-V substrate is removed by etching down to the first etch stop layer. Deposition windows are opened by etching from the first etch stop layer down to the contact layer. Metal contact electrodes are deposited in the deposition windows.

36 MATERIALS SCIENCE↗

Characterization of Advanced Manufactured Surface Acoustic Wave Sensor for Temperature Measurement in Nuclear Applications

As part of a collaborative effort between Idaho National Laboratory and the Boise State University, printed SAW transducers were developed. The transducers were first modelled and evaluated for optimum performance, then fabricated using several piezoelectric substrates. These printed SAW-sensors were tested for temperature sensing ability and found to be highly sensitive and with a very linear response over the tested range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Focusing transformers/filters in isotropic/anisotropic piezoelectrics

A focusing interdigital transducer (IDT) and corresponding single- and dual-port piezoelectric devices are disclosed. The focusing interdigital transducer, which generates Lamé acoustic waves, permits operation at significantly higher frequencies than those possible with traditional IDTs. The focusing IDT employs multiple arced fingers formed both above and below the piezoelectric layer to improve coupling efficiency by coupling through both the e31 and e33 piezoelectric coefficients to the piezoelectric layer. By optimizing both anchor design and location, acoustic wave losses are minimized, thereby improving the device's quality factor Q. Through proper bus design and selection of the number of IDT fingers, a device's impedance can be tuned for a given application. The focusing IDTs may be used in single-port filter devices and dual-port transformer devices. The single- and dual-port devices may operate at a single frequency, at two frequencies, or over a band of frequencies.

Siddiqui, Aleem↗

Detection, monitoring, and determination of location of changes in metallic structures using multimode acoustic signals

Acoustic transducers generate and receive acoustic signals at multiple locations along a surface of rigid structure, wherein longitudinal spacing between transducer locations define measurement zones. Acoustic signals with chosen amplitude-time-frequency characteristics excite multiple vibration modes in the structure within each zone. Small mechanical changes in inspection zones lead to scattering and attenuation of broadband acoustic signals, which are detectable as changes in received signal characteristics as part of a through-transmission technique. Additional use of short, narrowband pulse acoustic signals as part of a pulse-echo technique allows determination of the relative location of the mechanical change within each zone based on the differential delay profiles. For accurate acoustic modeling and simulation, the mesh size, time step, time delay, and time-window size are optimized. Frequency normalization of the Short-Time Fourier Transform of acoustic response output improves experiment-simulation cross-validation. Applications of the method to structures with arbitrarily complex geometries are also demonstrated.

Findikoglu, Alp Tugrul↗