Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Testing and Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

The effect of differential mineral shrinkage on crack formation and network geometry

Rock, concrete, and other engineered materials are often composed of several minerals that change volumetrically in response to variations in the moisture content of the local environment. Such differential shrinkage is caused by varying shrinkage rates between mineral compositions during dehydration. Using both 3D X-ray imaging of geo-architected samples and peridynamic (PD) numerical simulations, we show that the spatial distribution of the clay affects the crack network geometry with distributed clay particles yielding the most complex crack networks and percent damage (99.56%), along with a 60% reduction in material strength. We also demonstrate that crack formation, growth, coalescence, and distribution during dehydration, are controlled by the differential shrinkage rates between a highly shrinkable clay and a homogeneous mortar matrix. Sensitivity tests performed with the PD models show a clay shrinkage parameter of 0.4 yields considerable damage, and reductions in the parameter can result in a significant reduction in fracturing and an increase in material strength. Additionally, isolated clay inclusions induced localized fracturing predominantly due to debonding between the clay and matrix. These insights indicate differential shrinkage is a source of potential failure in natural and engineered barriers used to sequester anthropogenic waste.

58 GEOSCIENCES↗

Radiation-induced alteration of apatite on the surface of Mars: first in situ observations with SuperCam Raman onboard Perseverance

Abstract Planetary exploration relies considerably on mineral characterization to advance our understanding of the solar system, the planets and their evolution. Thus, we must understand past and present processes that can alter materials exposed on the surface, affecting space mission data. Here, we analyze the first dataset monitoring the evolution of a known mineral target in situ on the Martian surface, brought there as a SuperCam calibration target onboard the Perseverance rover. We used Raman spectroscopy to monitor the crystalline state of a synthetic apatite sample over the first 950 Martian days (sols) of the Mars2020 mission. We note significant variations in the Raman spectra acquired on this target, specifically a decrease in the relative contribution of the Raman signal to the total signal. These observations are consistent with the results of a UV-irradiation test performed in the laboratory under conditions mimicking ambient Martian conditions. We conclude that the observed evolution reflects an alteration of the material, specifically the creation of electronic defects, due to its exposure to the Martian environment and, in particular, UV irradiation. This ongoing process of alteration of the Martian surface needs to be taken into account for mineralogical space mission data analysis.

Science & Technology - Other Topics↗

Strain-induced structural defects and their effects on the electrochemical performances of silicon core/germanium shell nanowire heterostructures

Here we report on strain-induced structural defect formation in core Si nanowire of Si/Ge core/shell nanowire heterostructure and influences of the structural defects on the electrochemical performances in lithium-ion battery anodes based on Si/Ge core/shell nanowire heterostructures. The induced structural defects consisting of stacking faults and dislocations in the core Si nanowire were observed for the first time. The generation of stacking faults in Si/Ge core/shell nanowire heterostructure is observed to prefer settling in either only Ge shell region or in both Ge shell and Si core regions and is associated with the increase of the shell volume fraction. The relax of misfit strain in [112] oriented core/shell nanowire heterostructure leads to subsequent gliding of Shockley partial dislocations, preferentially forming the twins. The observation of cross-over defect formation is of great importance for the understanding of heteroepitaxy in radial heterostructures at nanoscale and building the three dimensional heterostructures for the various applications. In addition, the effect of the defect formation on nanomaterial’s functionality is investigated by electrochemical performance test. The Si/Ge core/shell nanowire heterostructures enhance the gravimetric capacity of lithium ion battery anodes under fast charging/discharging rates compared to Si nanowires. However, the induced structural defects hamper lithiation of the Si/Ge core/shell nanowire heterostructure.

36 MATERIALS SCIENCE↗

Enhancing the inherent catalytic activity and stability of TiO 2 supported Pt single-atoms at CeO x –TiO 2 interfaces

Single-atoms (SAs) with atomically coordinated reaction centers are considered the next generation of catalysts that can exhibit exceptional catalytic efficiency. However, the general concern about thermodynamic vulnerabilities of SAs questions their practical value. Moreover, whether the inherent catalytic nature of SAs is superior compared with that of larger nanoparticles is still under debate. Here, we address two controversies by a comparative study using two catalysts: Pt/TiO 2 and Pt/CeO x –TiO 2 . Based on a hierarchical study of density functional theory, time-resolved catalysis performance test, in situ infrared spectroscopy, and operando X-ray absorption spectroscopy, we could unveil the catalytic nature of Pt-SAs and their stability. By utilizing the heterogeneous interface formed between TiO 2 supporting particles and CeO x clusters formed on the surface of TiO 2 , we preferentially synthesized Pt-SAs pinned at the CeO x –TiO 2 interfaces on CeO x –TiO 2 hybrid-oxide supports. The strong electronic coupling between the Pt-SAs and the Ce ions at the CeO x –TiO 2 interfaces enhanced the catalytic activity toward CO oxidation of Pt-SAs and improved the long-term stability under CO oxidation conditions. The CO oxidation activity of Pt-SAs stabilized at CeO x –TiO 2 was improved by 13.5 times at 200 °C compared with the Pt-SAs on TiO 2 . The results present how to easily improve the activity and stability of Pt-SAs using a simple interface control method. Moreover, we demonstrate that the catalytic activity and the stability of Pt-SAs can be monitored through the chemical state of the interfaces. Finally, our study provides comprehensive understanding about the catalytic nature as well as a novel strategy toward applications of Pt-SAs, enabling sustainable use of Pt in heterogeneous catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

One-step fabrication of robust lithium ion battery separators by polymerization-induced phase separation

Conventional lithium ion battery separators are microporous polyolefin membranes that play a passive role in the electrochemical cell. Next generation separators should offer significant performance enhancements, while being fabricated through facile, low cost approaches with the ability to readily tune physicochemical properties. This study presents a single-step manufacturing technique based on UV-initiated polymerization-induced phase separation (PIPS), wherein microporous separators are fabricated from multifunctional monomers and ethylene carbonate (EC), which functions as both the pore-forming agent (porogen) and electrolyte component in the electrochemical cell. By controlling the ratio of the 1,4-butanediol diacrylate (BDDA) monomer to ethylene carbonate, monolithic microporous membranes are readily prepared with 25 μm thickness and pore sizes and porosities ranging from 6.8 to 22 nm and 15.4% to 38.5%, respectively. With 38.5% apparent porosity and an average pore size of 22 nm, the poly(1,4-butanediol diacrylate) (pBDDA) separator takes up 127% liquid electrolyte, resulting in an ionic conductivity of 1.98 mS cm –1 , which is greater than in conventional Celgard 2500. Lithium ion battery half cells consisting of LiNi 0.5 Mn 0.3 Co 0.2 O 2 cathodes and pBDDA separators were shown to undergo reversible charge/discharge cycling with an average discharge capacity of 142 mA h g –1 and a capacity retention of 98.4% over 100 cycles – comparable to cells using state-of-the-art separators. Moreover, similar discharge capacities were achieved in rate performance tests due to the high ionic conductivity and electrolyte uptake of the film. Finally, the pBDDA separators were shown to be thermally stable to 374 °C, lack low temperature thermal transitions that can compromise cell safety, and exhibit no thermal shrinkage up to 150 °C.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Recognition of Handwritten Arabic words using a neuro-fuzzy network

We present a new method for the recognition of handwritten Arabic words based on neuro-fuzzy hybrid network. As a first step, connected components (CCs) of black pixels are detected. Then the system determines which CCs are sub-words and which are stress marks. The stress marks are then isolated and identified separately and the sub-words are segmented into graphemes. Each grapheme is described by topological and statistical features. Fuzzy rules are extracted from training examples by a hybrid learning scheme comprised of two phases: rule generation phase from data using a fuzzy c-means, and rule parameter tuning phase using gradient descent learning. After learning, the network encodes in its topology the essential design parameters of a fuzzy inference system.The contribution of this technique is shown through the significant tests performed on a handwritten Arabic words database.

99 GENERAL AND MISCELLANEOUS↗

Simulation of a PET system and study of some geometry parameters

The Monte Carlo simulation of small animal conventional positron emission tomography (PET) is an important tool for geometry parameters optimization, image reconstruction algorithm tests, performance of different radioisotopic sources and some others. The present work deals with the Monte Carlo study of a small cylindrical PET system in the framework of the GEANT4 code. Two different accepted ring width values and spherical sources of {sup 18}F and {sup 44}Sc isotopes were considered. Then, the improvement of the detection efficiency and spatial resolution was analyzed in all the cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

New electromagnetic particle simulation code for the analysis of spacecraft-plasma interactions

A novel particle simulation code, the electromagnetic spacecraft environment simulator (EMSES), has been developed for the self-consistent analysis of spacecraft-plasma interactions on the full electromagnetic (EM) basis. EMSES includes several boundary treatments carefully coded for both longitudinal and transverse electric fields to satisfy perfect conductive surface conditions. For the longitudinal component, the following are considered: (1) the surface charge accumulation caused by impinging or emitted particles and (2) the surface charge redistribution, such that the surface becomes an equipotential. For item (1), a special treatment has been adopted for the current density calculated around the spacecraft surface, so that the charge accumulation occurs exactly on the surface. As a result, (1) is realized automatically in the updates of the charge density and the electric field through the current density. Item (2) is achieved by applying the capacity matrix method. Meanwhile, the transverse electric field is simply set to zero for components defined inside and tangential to the spacecraft surfaces. This paper also presents the validation of EMSES by performing test simulations for spacecraft charging and peculiar EM wave modes in a plasma sheath.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Single crystal chemical vapor deposited diamond detectors for intensity-modulated radiation therapy applications

We report here on first intensity-modulated radiation therapy (IMRT) clinical tests performed at the Gustave Roussy Institute in France using one small (0.117 mm{sup 3}) synthetic single crystal diamond detector (SCDD). We report the comparison between the point doses evaluated with our detector, with a PTW semiflex air ionization chamber (0.125 cm{sup 3}) and calculated with the treatment planning system (TPS), respectively. The obtained results show a maximum difference of 2.3% for the diamond detector and of 4.6% for the ionization chamber, as compared with the TPS calculations. These very promising results show the potentiality of chemical vapor deposited SCDD for dosimetry of IMRT fields and opens up the field for diamond dosimeters toward novel applications such as very small beam monitoring.

36 MATERIALS SCIENCE↗

Recent operation status of Japan Proton Accelerator Research Complex H{sup -} ion source

A cesium-free H{sup -} ion source driven with a LaB{sub 6} filament is being operated at the Japan Proton Accelerator Research Complex for approximately three years without any serious trouble. In the beam commissioning or supply runs, the ion source has been operated in two different modes such as low current mode of 5 mA and high current mode of 30 mA. The total interruption time during the runs due to the ion source failure is approximately 50 h, which correspond to the ion source availability of 99%. After a long-term operation, the surface of the filament and the plasma electrode become discolored with dark partially. The result of surface analysis with field emission scanning electron microscope showed that most of the dark material is formed with boron. At the beam test performed in the interval of the run, we demonstrated that the H{sup -} current increased by miniaturizing the LaB{sub 6} filament.

43 PARTICLE ACCELERATORS↗

A New Type of X-ray Condenser Lenses with Large Apertures Fabricated by Rolling of Structured Films

In order to meet the demand for X-ray lenses with large apertures and, hence, photon flux, a new type of X-ray lenses has been developed: Rolled prismatic X-ray lenses feature a vast number of refracting surfaces to increase transparency and aperture, respectively. Prototypes of such lenses have been fabricated by molding and rolling of a structured polyimide film. In this work, rolled prismatic X-ray lenses are pictured, and results of first tests performed at the ANKA storage ring in Karlsruhe are presented.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Compton Imaging Capabilities of AGATA for Background Rejection

In this work we present the results of the test performed at the Laboratori Nazionali di Legnaro (LNL) aiming to characterize the capabilities of the AGATA detectors to discriminate between different gamma source locations. AGATA detectors are position sensitive to the interaction points through Pulse Shape Analysis allowing location of the gamma sources by using Compton imaging algorithm. The final goal is to increase the array sensitivity reducing the background originated outside the AGATA target.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New Soft X-ray Beamline (BL10) at the SAGA Light Source

A new soft X-ray beamline (BL10) at the SAGA Light Source (SAGA-LS) was constructed at the end of 2008. Commissioning of this new beamline started at the beginning of 2009. Synchrotron radiation from a variably polarizing undulator (APPLE-II) can be used in this beamline. The obtained light is monochromatized by a varied-line-spacing plane grating monochromator with the variable included angle mechanism. Its designed resolving power and photon flux are 3,000-10,000 and 10{sup 12}-10{sup 9} photons/s at 300 mA, respectively. The performance test results were generally satisfactory. An overview of the optical design of the beamline and the current status of commissioning are reported.

43 PARTICLE ACCELERATORS↗

Adaptation of UVSOR-Type Plane-Grating Monochromator in Saga

The plane grating monochromator (PGM) is one of the most useful monochromators in the world. The design concept of the PGM originates from the characteristics of synchrotron radiation itself, namely parallel rays and small source size. Since the performance of the PGM depends on the beam emittance of the storage ring, it is expected that even the used PGM may be utilized in recent facility. Therefore, the UVSOR-type PGM that had been used for more than twenty years in UVSOR was adapted to the university's branch beamline in Saga-LS with several modifications. The performance tests were carried out with a photoelectron spectrometer, and the observed values were compared with the ray-tracing calculation. The results show that the adaptation of the UVSOR-type PGM is good enough to study new functional materials.

43 PARTICLE ACCELERATORS↗

Identification of an advanced constitutive model of Magnesium alloy AZ31B

The main aim of this paper is to study the flow behavior of the AZ31B magnesium alloy by means of tensile tests performed in extended ranges of temperature and strain rates. The flow stress-strain curves analyzed by power law type constitutive equation can only fit well with experimental curves at the work-hardening stage. A new mathematical model is studied to describe the softening behavior of material based on tensile experiments. The relative parameters are obtained by fitting the equation with the experimental data. The genetic algorithm has been used to obtain the global optimal fitting parameters. The comparison between the fitted and experimental data proves the effectiveness of the model. The results indicate that this model leads to a better simulation of the flow stress during the softening stage than that of the power law equation. Based on this model, the deep drawing process has been simulated with the commercial finite element code FORGE registered. The punch load and thickness distribution of AZ31 sheet have been studied. The study of the results is helpful to the application of the stamping technology for the magnesium alloy sheet.

36 MATERIALS SCIENCE↗

Lithium pellet production (LiPP): A device for the production of small spheres of lithium

With lithium as a fusion material gaining popularity, a method for producing lithium pellets relatively quickly has been developed for NSTX. The Lithium Pellet Production device is based on an injector with a sub-millimeter diameter orifice and relies on a jet of liquid lithium breaking apart into small spheres via the Plateau-Rayleigh instability. A prototype device is presented in this paper and for a pressure difference of {Delta}P= 5 Torr, spheres with diameters between 0.91 < D < 1.37 mm have been produced with an average diameter of D= 1.14 mm, which agrees with the developed theory. Successive tests performed at Princeton Plasma Physics Laboratory with Wood's metal have confirmed the dependence of sphere diameter on pressure difference as predicted.

36 MATERIALS SCIENCE↗

A portable hydro-thermo-mechanical loading cell for in-situ small angle neutron scattering studies of proton exchange membranes

A portable hydro-thermo-mechanical loading cell has been designed to enable in-situ small angle neutron scattering (SANS) studies of proton exchange membranes (PEM) under immersed tensile loadings at different temperatures. The cell consists of three main parts as follows: a letter-paper-size motor-driven mechanical load frame, a SANS friendly reservoir that provides stable immersed and thermal sample conditions, and a data acquisition & control system. The ex-situ tensile tests of Nafion 212 membranes demonstrated a satisfactory thermo-mechanical testing performance of the cell for either dry or immersed conditions at elevated temperatures. The in-situ SANS tensile measurements on the Nafion 212 membranes immersed in D2O at 70oC proved the feasibility and capability of the cell for small angle scattering study on deformation behaviors of PEM and other polymer materials under hydro-thermo-mechanical loading.

hydro-thermo-mechanical.↗

Metallic beam developments for the SPIRAL 2 project

The SPIRAL 2 facility, currently under construction, will provide either stable or radioactive beams at high intensity. In addition to the high intensity of stable beams, high charge states must be produced by the ion source to fulfill the RFQ LINAC injection requirements: Q/A = 1/3 at 60 kV ion source extraction voltage. Excepting deuterons and hydrogen, most of the stable beam requests concern metallic elements. The existing 18 GHz electron cyclotron resonance ion source (ECRIS) Phoenix V2 designed at LPSC Grenoble has been used for the tests and will be the source for the SPIRAL 2 commissioning. The tests performed at LPSC for calcium ({sup 40}Ca{sup 14+} and {sup 40}Ca{sup 16+}), nickel ({sup 58}Ni{sup 19+}), and sulfur ({sup 32}S{sup 11+}) are described and discussed. Due to the very high charge states required, the oven method has been chosen. An intensity of 1 pμA has been reached for those elements. The performance and the beam stability have been studied using different buffer gases, and some ionization efficiency preliminary results are given.

43 PARTICLE ACCELERATORS↗