Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

ADVANCED OXIDATION: OXALATE DECOMPOSITION TESTING WITH OZONE

At the Savannah River Site (SRS), oxalic acid is currently considered the preferred agent for chemically cleaning the large underground Liquid Radioactive Waste Tanks. It is applied only in the final stages of emptying a tank when generally less than 5,000 kg of waste solids remain, and slurrying based removal methods are no-longer effective. The use of oxalic acid is preferred because of its combined dissolution and chelating properties, as well as the fact that corrosion to the carbon steel tank walls can be controlled. Although oxalic acid is the preferred agent, there are significant potential downstream impacts. Impacts include: (1) Degraded evaporator operation; (2) Resultant oxalate precipitates taking away critically needed operating volume; and (3) Eventual creation of significant volumes of additional feed to salt processing. As an alternative to dealing with the downstream impacts, oxalate decomposition using variations of ozone based Advanced Oxidation Process (AOP) were investigated. In general AOPs use ozone or peroxide and a catalyst to create hydroxyl radicals. Hydroxyl radicals have among the highest oxidation potentials, and are commonly used to decompose organics. Although oxalate is considered among the most difficult organic to decompose, the ability of hydroxyl radicals to decompose oxalate is considered to be well demonstrated. In addition, as AOPs are considered to be 'green' their use enables any net chemical additions to the waste to be minimized. In order to test the ability to decompose the oxalate and determine the decomposition rates, a test rig was designed, where 10 vol% ozone would be educted into a spent oxalic acid decomposition loop, with the loop maintained at 70 C and recirculated at 40L/min. Each of the spent oxalic acid streams would be created from three oxalic acid strikes of an F-area simulant (i.e., Purex = high Fe/Al concentration) and H-area simulant (i.e., H area modified Purex = high Al/Fe concentration) after nearing dissolution equilibrium, and then decomposed to {le} 100 Parts per Million (ppm) oxalate. Since AOP technology largely originated on using ultraviolet (UV) light as a primary catalyst, decomposition of the spent oxalic acid, well exposed to a medium pressure mercury vapor light was considered the benchmark. However, with multi-valent metals already contained in the feed, and maintenance of the UV light a concern; testing was conducted to evaluate the impact from removing the UV light. Using current AOP terminology, the test without the UV light would likely be considered an ozone based, dark, ferrioxalate type, decomposition process. Specifically, as part of the testing, the impacts from the following were investigated: (1) Importance of the UV light on the decomposition rates when decomposing 1 wt% spent oxalic acid; (2) Impact of increasing the oxalic acid strength from 1 to 2.5 wt% on the decomposition rates; and (3) For F-area testing, the advantage of increasing the spent oxalic acid flowrate from 40 L/min (liters/minute) to 50 L/min during decomposition of the 2.5 wt% spent oxalic acid. The results showed that removal of the UV light (from 1 wt% testing) slowed the decomposition rates in both the F & H testing. Specifically, for F-Area Strike 1, the time increased from about 6 hours to 8 hours. In H-Area, the impact was not as significant, with the time required for Strike 1 to be decomposed to less than 100 ppm increasing slightly, from 5.4 to 6.4 hours. For the spent 2.5 wt% oxalic acid decomposition tests (all) without the UV light, the F-area decompositions required approx. 10 to 13 hours, while the corresponding required H-Area decompositions times ranged from 10 to 21 hours. For the 2.5 wt% F-Area sludge, the increased availability of iron likely caused the increased decomposition rates compared to the 1 wt% oxalic acid based tests. In addition, for the F-testing, increasing the recirculation flow rates from 40 liter/minute to 50 liter/minute resulted in an increased decomposition rate, suggesting a better use of ozone.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PHASE II VAULT TESTING OF THE ARGONNE RFID SYSTEM

The U.S. Department of Energy (DOE) (Environmental Management [EM], Office of Packaging and Transportation [EM-45]) Packaging and Certification Program (DOE PCP) has developed a Radio Frequency Identification (RFID) tracking and monitoring system, called ARG-US, for the management of nuclear materials packages during transportation and storage. The performance of the ARG-US RFID equipment and system has been fully tested in two demonstration projects in April 2008 and August 2009. With the strong support of DOE-SR and DOE PCP, a field testing program was completed in Savannah River Site's K-Area Material Storage (KAMS) Facility, an active Category I Plutonium Storage Facility, in 2010. As the next step (Phase II) of continued vault testing for the ARG-US system, the Savannah River Site K Area Material Storage facility has placed the ARG-US RFIDs into the 910B storage vault for operational testing. This latest version (Mark III) of the Argonne RFID system now has the capability to measure radiation dose and dose rate. This paper will report field testing progress of the ARG-US RFID equipment in KAMS, the operability and reliability trend results associated with the applications of the system, and discuss the potential benefits in enhancing safety, security and materials accountability. The purpose of this Phase II K Area test is to verify the accuracy of the radiation monitoring and proper functionality of the ARG-US RFID equipment and system under a realistic environment in the KAMS facility. Deploying the ARG-US RFID system leads to a reduced need for manned surveillance and increased inventory periods by providing real-time access to status and event history traceability, including environmental condition monitoring and radiation monitoring. The successful completion of the testing program will provide field data to support a future development and testing. This will increase Operation efficiency and cost effectiveness for vault operation. As the next step (Phase II) of continued vault testing for the ARG-US system, the Savannah River Site K Area Material Storage facility has placed the ARG-US RFIDs into the 910B storage vault. Deploying the ARG-US RFID system lends to a reduced need for manned surveillance and increased inventory periods by providing real-time access to status and event history traceability, including radiation and environmental monitoring. The successful completion of the testing program will provide field data to support future development and testing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Testing military grade magnetics (transformers, inductors and coils).

Engineers and designers are constantly searching for test methods to qualify or 'prove-in' new designs. In the High Reliability world of military parts, design test, qualification tests, in process tests and product characteristic tests, become even more important. The use of in process and function tests has been adopted as a way of demonstrating that parts will operate correctly and survive its 'use' environments. This paper discusses various types of tests to qualify the magnetic components - the current carrying capability of coils, a next assembly 'as used' test, a corona test and inductance at temperature test. Each of these tests addresses a different potential failure on a component. The entire process from design to implementation is described.

36 MATERIALS SCIENCE↗

HIGH-TEMPERATURE SAFETY TESTING OF IRRADIATED AGR-1 TRISO FUEL

High-Temperature Safety Testing of Irradiated AGR-1 TRISO Fuel John D. Stempien, Paul A. Demkowicz, Edward L. Reber, and Cad L. Christensen Idaho National Laboratory, P.O. Box 1625 Idaho Falls, ID 83415, USA Corresponding Author: john.stempien@inl.gov, +1-208-526-8410 Two new safety tests of irradiated tristructural isotropic (TRISO) coated particle fuel have been completed in the Fuel Accident Condition Simulator (FACS) furnace at the Idaho National Laboratory (INL). In the first test, three fuel compacts from the first Advanced Gas Reactor irradiation experiment (AGR-1) were simultaneously heated in the FACS furnace. Prior to safety testing, each compact was irradiated in the Advanced Test Reactor to a burnup of approximately 15 % fissions per initial metal atom (FIMA), a fast fluence of 3×1025 n/m2 (E > 0.18 MeV), and a time-average volume-average (TAVA) irradiation temperature of about 1020 °C. In order to simulate a core-conduction cool-down event, a temperature-versus-time profile having a peak temperature of 1700 °C was programmed into the FACS furnace controllers. Gaseous fission products (i.e., Kr-85) were carried to the Fission Gas Monitoring System (FGMS) by a helium sweep gas and captured in cold traps featuring online gamma counting. By the end of the test, a total of 3.9% of an average particle’s inventory of Kr-85 was detected in the FGMS traps. Such a low Kr-85 activity indicates that no TRISO failures (failure of all three TRISO layers) occurred during the test. If released from the compacts, condensable fission products (e.g., Ag-110m, Cs-134, Cs-137, Eu-154, Eu-155, and Sr-90) were collected on condensation plates fitted to the end of the cold finger in the FACS furnace. These condensation plates were then analyzed for fission products. In the second test, five loose UCO fuel kernels, obtained from deconsolidated particles from an irradiated AGR-1 compact, were heated in the FACS furnace to a peak temperature of 1600 °C. This test had two primary goals. First, the test was intended to assess the retention of fission products in loose kernels without the effects of the other TRISO layers (buffer, IPyC, SiC, and OPyC) or the graphitic matrix material comprising the compact. Second, this test served as an evaluation of the FACS fission product condensation plate collection efficiency.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analyses Supporting Design Review of TREAT Multi-SERTTA Experiment Test Vehicle

The Transient Test Reactor (TREAT) Facility was designed to evaluate nuclear fuels and structural materials under simulated nuclear excursion and transient power/cooling mismatch situations that could be encountered in nuclear reactors [1]. It was historically operated from 1959 through 1994; ongoing activities at Idaho National Laboratory (INL) include resumption of transient testing capabilities to generate experimental data suitable to validate advanced modeling and simulation of these transient conditions, supporting current and next generation power reactor design and nuclear safety [2]. The resumption of transient testing requires new experiment vehicle designs to satisfy testing needs. The most developed experiment test vehicle candidate in TREAT’s arsenal will be the Multi-SERTTA (Static Environment Rodlet Transient Test Apparatuses) [3], which accommodates up to four concurrent rodlets under separate environmental conditions. An overview of the Multi-SERTTA, which would be placed at the center of the TREAT core during use, is shown in Figure 1. In the current design, all four rodlet test vessels are identical except for flux shaping collar material content to meet design needs. As the date rapidly approaches for TREAT restart, there is a need to have the Multi-SERTTA design approved and tested. Test experiments are an integral component of TREAT operations, and will be integrated among initial restart testing and supporting core reactor physics measurements. An integral step in finalization of any test vehicle design for TREAT is the hosting and resolution of a formal design review.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Endurance test of helium circulator for HTR-PM - 18531

High-temperature Gas-cooled Reactor Pebble-bed Module (HTR-PM) will be built as the world's first pebble-bed type modular HTGR commercial demonstration plant according to Chinese National science and technology program. HTR-PM will be expected to begin generating electricity in the end of 2017 in Shidao bay of China. Helium circulator is one of critical component of HTR-PM, which circulates reactor coolant through the reactor core and steam generators. The helium circulator was designed to be a vertical layout and its rotor was supported by active magnet bearings (AMBs). The whole circulator including motor and cooler was sealed in a pressure vessel. Since it is a large mechanical and electrical equipment and the design is totally advanced integrated with many new technologies, experiment study of helium circulator would be significant for safe and reliable operation of HTR-PM plant in the future. For the lack of engineering experience of this equipment, it was necessary to manufacture a prototype for tests. Meanwhile, Engineering Test Facility- Helium Circulator. ETF-HC was built in Institute of Nuclear and New Energy Technology (INET) for the tests. The prototype is completely same as the real machine for the plant. After prototype fabrication, nitrogen test was firstly conducted in the factory by the manufacturer, designer and users. After successful factory test, the prototype was delivered to INET to be tested in ETF-HC. Although nitrogen simulation test had been completed successfully, helium endurance test has been continually carried out in ETF-HC for one and half years because of several sealing problems caused by helium. After solving all kinds of problem in the field, helium circulator run continuously 50 hours under rated condition. Furthermore, 50 service cycles test was conducted in ETF-HC. More than 500 operation hours was accumulated during endurance test. Throughout the final performance test, a conclusion can be made that the helium circulator performance met the design requirements and its feasibility, availability and reliability was verified. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Post-Transient Examination Results of RIA Commissioning Teats at the Transient Reactor Test Facility

Six reactivity-initiated-accident (RIA) commissioning tests have been performed at Idaho National Laboratory’s (INL) Transient Reactor Test Facility. Five of these tests were performed using fresh fuel rodlets, and the sixth test was performed using a previously irradiated rodlet from the ATF-2 irradiation experiment. These experiments demonstrate the ability to perform RIA testing including the ability to perform experiments using previously irradiated materials. Post-transient examinations revealed pellet cladding interactions and cladding ballooning depending on the initial boundary conditions of the test. Increased thickness of both zirconium oxide and alpha-zirconium were found in the cladding with tests performed at higher levels of total energy deposition. No oxide or alpha-zirconium was found in the test with the greatest amount of ballooning, which was also the test with the highest initial rod internal pressure. The highest energy deposition test (1110 J/g) resulted in failure of the rodlet. Fragmentation of the fuel pellets occurred in this test with the size of the fragments decreasing inversely to the pellet radius.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Pre-Transient Characterization of Historic EBR-II Pins for Transient Testing

Current interest in sodium-cooled fast reactor (SFR) designs, such as TerraPower’s Natrium Reactor, has highlighted the need for advanced reactor fuel technology development. Modern U-Zr and U- Pu-Zr pin designs are primary candidates to fuel SFRs and boast high fuel utilization capacity, increased fuel-cladding compatibility, and improved safety through inherent feedback mechanisms. Despite over 60 years of metallic fuel irradiation, uncertainties exist in the performance of the fuel system, particularly under transient overpower (TOP) and loss of flow (LOF) scenarios. Throughout historical testing within the Experimental Breeder Reactor II (EBR-II) and the Fast Flux Test Facility (FFTF), fuel behavior has demonstrated benign response to transient reactor conditions; however, accurate predictions of failure thresholds to inform operational limitations rely heavily on fuel composition, burnup, and irradiation history. In expanding TOP and LOF testing, the Transient Heat sink Overpower Response (THOR) Capsule will be used to test modern fuel technologies in a static sodium environment in the Transient Reactor Test (TREAT) Facility. The THOR capsule is highly instrumented and will provide time-dependent thermal behavior of SFR fuel pins subjected to accident conditions within TREAT. The THOR-Metallic (THOR- M) campaign aims to validate and expand historical TOP and LOF testing on high burnup U-Zr and U-Pu- Zr fuel alloys previously irradiated in EBR-II by running the rods to failure. This contribution focuses primarily on the pre-transient engineering-scale destructive and non- destructive characterization that has been conducted on both the test and sibling pins used for the TOP and LOF tests. All pins underwent visual examination, neutron radiography, element contact profilometry, and precise gamma scan. The sibling pins used for each test were further analyzed using gas assay, sampling, and recharge analysis (GASR), and optical microscopy. The results from each technique confirmed that the fuel pins were intact and devoid of any atypical developments when compared to historical data. Additionally, the analyzed measurements establish a baseline for comparison to post-transient analysis. Key fuel behaviors quanitifed include axial elongation of the fuel column, diametral strain of the pin, patterns in fluff structure geometry, changes in axial isotope distribution, evolution of constituent redistribution, porosity, and fission gas release. The pre-transient measurements and changes attributed to transient behavior from post-transient measurement will be compared to historical data to capture the behavioral dependence on composition, burnup, and irradiation history. Results from this work advance the initiatives of the THOR-M campaign, which aid in informing fuel performance models and establishing safety criteria for SFR operational limits. The novel combination of test environment, in-situ instrumentation, and comprehensive suite of characterization methods provides greater understanding of transient fuel behavior. Overall, information on the time and condition of pin failure for high burnup U-Pu-Zr will greatly expand the limited existing TOP and LOF test data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Pre-Transient Characterization of Historic EBR-II Pins for Transient Testing

Current interest in sodium-cooled fast reactor (SFR) designs, such as TerraPower’s Natrium Reactor, has highlighted the need for advanced reactor fuel technology development. Modern U-Zr and U- Pu-Zr pin designs are primary candidates to fuel SFRs and boast high fuel utilization capacity, increased fuel-cladding compatibility, and improved safety through inherent feedback mechanisms. Despite over 60 years of metallic fuel irradiation, uncertainties exist in the performance of the fuel system, particularly under transient overpower (TOP) and loss of flow (LOF) scenarios. Throughout historical testing within the Experimental Breeder Reactor II (EBR-II) and the Fast Flux Test Facility (FFTF), fuel behavior has demonstrated benign response to transient reactor conditions; however, accurate predictions of failure thresholds to inform operational limitations rely heavily on fuel composition, burnup, and irradiation history. In expanding TOP and LOF testing, the Transient Heat sink Overpower Response (THOR) Capsule will be used to test modern fuel technologies in a static sodium environment in the Transient Reactor Test (TREAT) Facility. The THOR capsule is highly instrumented and will provide time-dependent thermal behavior of SFR fuel pins subjected to accident conditions within TREAT. The THOR-Metallic (THOR- M) campaign aims to validate and expand historical TOP and LOF testing on high burnup U-Zr and U-Pu- Zr fuel alloys previously irradiated in EBR-II by running the rods to failure. This contribution focuses primarily on the pre-transient engineering-scale destructive and non- destructive characterization that has been conducted on both the test and sibling pins used for the TOP and LOF tests. All pins underwent visual examination, neutron radiography, element contact profilometry, and precise gamma scan. The sibling pins used for each test were further analyzed using gas assay, sampling, and recharge analysis (GASR), and optical microscopy. The results from each technique confirmed that the fuel pins were intact and devoid of any atypical developments when compared to historical data. Additionally, the analyzed measurements establish a baseline for comparison to post-transient analysis. Key fuel behaviors quanitifed include axial elongation of the fuel column, diametral strain of the pin, patterns in fluff structure geometry, changes in axial isotope distribution, evolution of constituent redistribution, porosity, and fission gas release. The pre-transient measurements and changes attributed to transient behavior from post-transient measurement will be compared to historical data to capture the behavioral dependence on composition, burnup, and irradiation history. Results from this work advance the initiatives of the THOR-M campaign, which aid in informing fuel performance models and establishing safety criteria for SFR operational limits. The novel combination of test environment, in-situ instrumentation, and comprehensive suite of characterization methods provides greater understanding of transient fuel behavior. Overall, information on the time and condition of pin failure for high burnup U-Pu-Zr will greatly expand the limited existing TOP and LOF test data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FY 2016 Status Report: CIRFT Testing Data Analyses and Updated Curvature Measurements

This report provides a detailed description of FY15 test result corrections/analysis based on the FY16 Cyclic Integrated Reversible-Bending Fatigue Tester (CIRFT) test program methodology update used to evaluate the vibration integrity of spent nuclear fuel (SNF) under normal transportation conditions. The CIRFT consists of a U-frame testing setup and a real-time curvature measurement method. The three-component U-frame setup of the CIRFT has two rigid arms and linkages to a universal testing machine. The curvature of rod bending is obtained through a three-point deflection measurement method. Three linear variable differential transformers (LVDTs) are used and clamped to the side connecting plates of the U-frame to capture the deformation of the rod. The contact-based measurement, or three-LVDT-based curvature measurement system, on SNF rods has been proven to be quite reliable in CIRFT testing. However, how the LVDT head contacts the SNF rod may have a significant effect on the curvature measurement, depending on the magnitude and direction of rod curvature. It has been demonstrated that the contact/curvature issues can be corrected by using a correction on the sensor spacing. The sensor spacing defines the separation of the three LVDT probes and is a critical quantity in calculating the rod curvature once the deflections are obtained. The sensor spacing correction can be determined by using chisel-type probes. The method has been critically examined this year and has been shown to be difficult to implement in a hot cell environment, and thus cannot be implemented effectively. A correction based on the proposed equivalent gauge-length has the required flexibility and accuracy and can be appropriately used as a correction factor. The correction method based on the equivalent gauge length has been successfully demonstrated in CIRFT data analysis for the dynamic tests conducted on Limerick (LMK) (17 tests), North Anna (NA) (6 tests), and Catawba mixed oxide (MOX) (10 tests) SNF samples. These CIRFT tests were completed in FY14 and FY15. Specifically, the data sets obtained from measurement and monitoring were processed and analyzed. The fatigue life of rods has been characterized in terms of moment, curvature, and equivalent stress and strain..

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Wind Turbine Generator System Duration Test Report for the Mariah Power Windspire Wind Turbine

This test was conducted as part of the U.S. Department of Energy's (DOE) Independent Testing project to help reduce the barriers of wind energy expansion by providing independent testing results for small turbines. In total, five turbines are being tested at the National Wind Technology Center (NWTC) as a part of the first round of this project. Duration testing is one of up to five tests that may be performed on the turbines. Other tests include power performance, safety and function, noise, and power quality tests. NWTC testing results provide manufacturers with reports that may be used to meet part of small wind turbine certification requirements. This duration test report focuses on the Mariah Power Windspire wind turbine.

17 WIND ENERGY↗

On the reliability of microvariability tests in quasars

Microvariations probe the physics and internal structure of quasars. Unpredictability and small flux variations make this phenomenon elusive and difficult to detect. Variance-based probes such as the C and F tests, or a combination of both, are popular methods to compare the light curves of the quasar and a comparison star. Recently, detection claims in some studies have depended on the agreement of the results of the C and F tests, or of two instances of the F-test, for rejecting the non-variation null hypothesis. However, the C-test is a non-reliable statistical procedure, the F-test is not robust, and the combination of tests with concurrent results is anything but a straightforward methodology. A priori power analysis calculations and post hoc analysis of Monte Carlo simulations show excellent agreement for the analysis of variance test to detect microvariations as well as the limitations of the F-test. Additionally, the combined tests yield correlated probabilities that make the assessment of statistical significance unworkable. However, it is possible to include data from several field stars to enhance the power in a single F-test, increasing the reliability of the statistical analysis. This would be the preferred methodology when several comparison stars are available. An example using two stars and the enhanced F-test is presented. These results show the importance of using adequate methodologies and avoiding inappropriate procedures that can jeopardize microvariability detections. Power analysis and Monte Carlo simulations are useful tools for research planning, as they can demonstrate the robustness and reliability of different research approaches.

79 ASTRONOMY AND ASTROPHYSICS↗

Processing Aleatory and Epistemic Uncertainties in Experimental Data From Sparse Replicate Tests of Stochastic Systems for Real-Space Model Validation

This paper presents a practical methodology for propagating and processing uncertainties associated with random measurement and estimation errors (that vary from test-to-test) and systematic measurement and estimation errors (uncertain but similar from test-to-test) in inputs and outputs of replicate tests to characterize response variability of stochastically varying test units. Also treated are test condition control variability from test-to-test and sampling uncertainty due to limited numbers of replicate tests. These aleatory variabilities and epistemic uncertainties result in uncertainty on computed statistics of output response quantities. The methodology was developed in the context of processing experimental data for “real-space” (RS) model validation comparisons against model-predicted statistics and uncertainty thereof. The methodology is flexible and sufficient for many types of experimental and data uncertainty, offering the most extensive data uncertainty quantification (UQ) treatment of any model validation method the authors are aware of. It handles both interval and probabilistic uncertainty descriptions and can be performed with relatively little computational cost through use of simple and effective dimension- and order-adaptive polynomial response surfaces in a Monte Carlo (MC) uncertainty propagation approach. A key feature of the progressively upgraded response surfaces is that they enable estimation of propagation error contributed by the surrogate model. Sensitivity analysis of the relative contributions of the various uncertainty sources to the total uncertainty of statistical estimates is also presented. Finally, the methodologies are demonstrated on real experimental validation data involving all the mentioned sources and types of error and uncertainty in five replicate tests of pressure vessels heated and pressurized to failure. Simple spreadsheet procedures are used for all processing operations.

97 MATHEMATICS AND COMPUTING↗

Multileaf collimator performance monitoring and improvement using semiautomated quality control testing and statistical process control

Purpose: High-quality radiation therapy using highly conformal dose distributions and image-guided techniques requires optimum machine delivery performance. In this work, a monitoring system for multileaf collimator (MLC) performance, integrating semiautomated MLC quality control (QC) tests and statistical process control tools, was developed. The MLC performance monitoring system was used for almost a year on two commercially available MLC models. Control charts were used to establish MLC performance and assess test frequency required to achieve a given level of performance. MLC-related interlocks and servicing events were recorded during the monitoring period and were investigated as indicators of MLC performance variations. Methods: The QC test developed as part of the MLC performance monitoring system uses 2D megavoltage images (acquired using an electronic portal imaging device) of 23 fields to determine the location of the leaves with respect to the radiation isocenter. The precision of the MLC performance monitoring QC test and the MLC itself was assessed by detecting the MLC leaf positions on 127 megavoltage images of a static field. After initial calibration, the MLC performance monitoring QC test was performed 3–4 times/week over a period of 10–11 months to monitor positional accuracy of individual leaves for two different MLC models. Analysis of test results was performed using individuals control charts per leaf with control limits computed based on the measurements as well as two sets of specifications of ±0.5 and ±1 mm. Out-of-specification and out-of-control leaves were automatically flagged by the monitoring system and reviewed monthly by physicists. MLC-related interlocks reported by the linear accelerator and servicing events were recorded to help identify potential causes of nonrandom MLC leaf positioning variations. Results: The precision of the MLC performance monitoring QC test and the MLC itself was within ±0.22 mm for most MLC leaves and the majority of the apparent leaf motion was attributed to beam spot displacements between irradiations. The MLC QC test was performed 193 and 162 times over the monitoring period for the studied units and recalibration had to be repeated up to three times on one of these units. For both units, rate of MLC interlocks was moderately associated with MLC servicing events. The strongest association with the MLC performance was observed between the MLC servicing events and the total number of out-of-control leaves. The average elapsed time for which the number of out-of-specification or out-of-control leaves was within a given performance threshold was computed and used to assess adequacy of MLC test frequency. Conclusions: A MLC performance monitoring system has been developed and implemented to acquire high-quality QC data at high frequency. This is enabled by the relatively short acquisition time for the images and automatic image analysis. The monitoring system was also used to record and track the rate of MLC-related interlocks and servicing events. MLC performances for two commercially available MLC models have been assessed and the results support monthly test frequency for widely accepted ±1 mm specifications. Higher QC test frequency is however required to maintain tighter specification and in-control behavior.

07 ISOTOPE AND RADIATION SOURCES↗

MASK4 Test Campaign for Sandia WaveBot Device

This data and report details the findings from a wave tank test focused on production of useful work of a wave energy converter (WEC) device. The experimental system and test were specifically designed to validate models for power transmission throughout the WEC system. Additionally, the validity of co-design informed changes to the power take-off (PTO) were assessed and shown to provide the expected improvements in system performance. These data describe the "MASK4" wave tank test of the Sandia WaveBot device. The WaveBot device has been tested a number of times in different permutations at the US Navy's Maneuvering and Sea Keeping (MASK) basin. Each test in this series is referred to as MASK1, MASK2, etc. The WaveBot device was first tested in one degree of freedom (heave) in 2016. This MASK1 test focused primarily on system identification and modeling. After MASK1, major modifications were performed to improve the overall real-time control and measurement system, improve the heave drive train, and add surge and pitch degrees of freedom. The second set of testing, which was broken up in to two stages: MASK2A and MASK2B, focused on bench testing and closed-loop control performance as well as nonlinear modeling. MASK3 then focused on multi-input, multi-output modeling and control for maximization of electrical power. The attached report presents the results from MASK4, which focuses on detailed modeling of the power conversion chain and validation co-design principles by way of the introduction of a magnetic spring. The test log, report, and data from the MASK4 test of the WaveBot augmented with a tunable magnetic spring. Processing codes can be found at the Github link below.

16 TIDAL AND WAVE POWER↗

Recent Cryogenic Carbon Capture™ Field Test Results

Sustainable Energy Solutions (SES) has been developing Cryogenic Carbon Capture™ (CCC) since 2008. In that time, two processes have been developed, the External Cooling Loop and Compressed Flue Gas CCC processes (CCC-ECL and CCC-CFG, respectively). The CCC-ECL process cools the flue gas with an external refrigerant loop. This process currently captures up to 1 tonne of CO2 per day (TPD). SES has tested CCC-ECL on real flue gas slip streams from subbituminous coal, bituminous coal, biomass, natural gas, shredded tires, and municipal waste fuels at field sites that include utility power stations, heating plants, cement kilns, and pilot-scale research reactors. The CO2 concentrations from these tests ranged from 5 to 22% on a dry basis. CO2 capture ranged from 95-99+% during these tests. Several other condensable species were also captured including NO2, SO2 and PMxx at 95+%. NO was also captured at a modest rate. The CCC-CFG process has been scaled up to a 0.25 ton per day system. This system has been tested on real flue gas streams including subbituminous coal, bituminous coal, and natural gas at field sites that include utility power stations, heating plants, and pilot-scale research reactors. CO2 concentrations for these tests ranged from 5 to 15% on a dry basis. CO2 capture ranged from 95-99+% during these tests. Several other condensable species were also captured including NO2, SO2, and PMxx at 95+%. NO was also captured at 90+%. Hg capture was also verified and the resulting effluent from CCC-CFG was below a 1ppt concentration. This paper will focus on discussion of the capabilities of CCC generally, the results of CCC-ECL field testing, and future steps surrounding the development of this technology. Test results that will be presented have been collected during 9 months of testing at a commercial power plant under funding from the US Department of Energy (DOE) and the host utility. Testing of one of the systems at a commercial cement plant in the United States will also be discussed. During this testing, the system captured CO2 from the cement plant and stored the CO2 in pressurized tanks. These tanks were provided to a partner company that later used the CO2 in a CO2 utilization demonstration. The CO2 was utilized to cure concrete manufactured using cement from the same plant where the CO2 was captured. This integrated capture and utilization demonstration was the first time that the cement industry has shown in the field that it can sequester its CO2 emissions in its main product stream. This represents a potential game changing solution for industrial CO2 emissions. Operational data and host-site feedback indicate that the CCC process is ideally suited for deployment into a variety of commercial environments. A few areas of de-risking remain to make sure the technology can meet very strict industrial reliability standards. These areas of de-risking are identified and discussed. The product CO2 is shown to meet specification for many uses including industrial and merchant applications. The technology is nearing readiness for deployment at commercial scale and several initial target markets have been identified.

20 FOSSIL-FUELED POWER PLANTS↗

Electric Power Delivery Testing Feasibility Study (Task 6 Final Report)

This Final Report is covers the completion of the Electric Power Delivery Testing Feasibility Study. The objective of this project was to research, engineer, and demonstrate high-power laboratory testing protocols to accurately reproduce the conditions on the electric power grid representing both normal load switching and abnormalities such as short-circuit fault protection. Test circuits, equipment, and techniques were developed and proven at reduced power levels to determine the feasibility of building a large-scale high-power testing laboratory capable of testing equipment and systems at simulated high-power conditions of the U.S. power grid at distribution levels up through 38 kiloVolts (kV) and transmission levels up through 230 kV. The project delivered demonstrated testing techniques, high-voltage test equipment for load testing and synthetic short-circuit testing, and recommended designs for future implementation of a high-power testing laboratory to test equipment and systems, enabling increased reliability of the electric transmission and distribution grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Industrial Gas Turbine Engine Catalytic Pilot Combustor-Prototype Testing

PCI has developed and demonstrated its Rich Catalytic Lean-burn (RCL®) technology for industrial and utility gas turbines to meet DOE's goals of low single digit emissions. The technology offers stable combustion with extended turndown allowing ultra-low emissions without the cost of exhaust after-treatment and further increasing overall efficiency (avoidance of after-treatment losses). The objective of the work was to develop and demonstrate emission benefits of the catalytic technology to meet strict emissions regulations. Two different applications of the RCL® concept were demonstrated: RCL® catalytic pilot and Full RCL®. The RCL® catalytic pilot was designed to replace the existing pilot (a typical source of high NOx production) in the existing Dry Low NOx (DLN) injector, providing benefit of catalytic combustion while minimizing engine modification. This report discusses the development and single injector and engine testing of a set of T70 injectors equipped with RCL® pilots for natural gas applications. The overall (catalytic pilot plus main injector) program NOx target of less than 5 ppm (corrected to 15% oxygen) was achieved in the T70 engine for the complete set of conditions with engine CO emissions less than 10 ppm. Combustor acoustics were low (at or below 0.1 psi RMS) during testing. The RCL® catalytic pilot supported engine startup and shutdown process without major modification of existing engine controls. During high pressure testing, the catalytic pilot showed no incidence of flashback or autoignition while operating over a wide range of flame temperatures. In applications where lower NOx production is required (i.e. less than 3 ppm), in parallel, a Full RCL® combustor was developed that replaces the existing DLN injector providing potential for maximum emissions reduction. This concept was tested at industrial gas turbine conditions in a Solar Turbines, Incorporated high-pressure (17 atm.) combustion rig and in a modified Solar Turbines, Incorporated Saturn engine rig. High pressure single-injector rig and modified engine rig tests demonstrated NOx less than 2 ppm and CO less than 10 ppm over a wide flame temperature operating regime with low combustion noise (<0.15% peak-to-peak). Minimum NOx for the optimized engine retrofit Full RCL® designs was less than 1 ppm with CO emissions less than 10 ppm. Durability testing of the substrate and catalyst material was successfully demonstrated at pressure and temperature showing long term stable performance of the catalytic reactor element. Stable performance of the reactor element was achieved when subjected to durability tests (>5000 hours) at simulated engine conditions (P=15 atm, Tin=400C/750F.). Cyclic tests simulating engine trips was also demonstrated for catalyst reliability. In addition to catalyst tests, substrate oxidation testing was also performed for downselected substrate candidates for over 25,000 hours. At the end of the program, an RCL® catalytic pilot system has been developed and demonstrated to produce NOx emissions of less than 3 ppm (corrected to 15% O2) for 100% and 50% load operation in a production engine operating on natural gas. In addition, a Full RCL® combustor has been designed and demonstrated less than 2 ppm NOx (with potential to achieve 1 ppm) in single injector and modified engine testing. The catalyst/substrate combination has been shown to be stable up to 5500 hrs in simulated engine conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗