Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TEST METHOD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Life-Prediction Parameters of Sapphire Determined for the Design of a Space Station Combustion Facility Window

To characterize the stress corrosion parameters and predict the life of a sapphire window being considered for use in the International Space Station's Fluids and Combustion Facility, researchers at the NASA Glenn Research Center conducted stress corrosion tests, fracture toughness tests, and reliability analyses, as shown in the figures. Standardized test methods, developed and updated by the author under the auspices of American Society for Testing and Materials, were employed. One interesting finding is that sapphire exhibits a susceptibility to stress corrosion in water similar to that of glass. In addition to generating the stress corrosion parameters and fracture toughness data, closed-form expressions for the variances of the crack growth parameters were derived. The expressions allow confidence bands to be easily placed on life predictions of ceramic components. Brittle materials such as sapphire and quartz are required for windows in a variety of applications such as the Fluids and Combustion Facility. To minimize the launch weight of such facilities, researchers must design the windows to be as lightweight as possible. The safe use of lightweight, brittle windows in structural applications is limited by two factors: low fracture toughness and slow crack growth, or stress corrosion. Stress corrosion of these and other optical materials can occur in relatively common environments, such as humid air. Access to the data has been requested by designers for use in the life prediction of a Northrop Grumman F16 instrument window and a Jet Propulsion Laboratory instrument window. One Space Act Agreement has been formed. Future work includes the measurement of the life of subscale windows.

Salem, Jonathan A.↗

Practical Applications of Cosmic Ray Science: Spacecraft, Aircraft, Ground Based Computation and Control Systems and Human Health and Safety

In this paper we review the discovery of cosmic ray effects on the performance and reliability of microelectronic systems as well as on human health and safety, as well as the development of the engineering and health science tools used to evaluate and mitigate cosmic ray effects in earth surface, atmospheric flight, and space flight environments. Three twentieth century technological developments, 1) high altitude commercial and military aircraft; 2) manned and unmanned spacecraft; and 3) increasingly complex and sensitive solid state micro-electronics systems, have driven an ongoing evolution of basic cosmic ray science into a set of practical engineering tools (e.g. ground based test methods as well as high energy particle transport and reaction codes) needed to design, test, and verify the safety and reliability of modern complex electronic systems as well as effects on human health and safety. The effects of primary cosmic ray particles, and secondary particle showers produced by nuclear reactions with spacecraft materials, can determine the design and verification processes (as well as the total dollar cost) for manned and unmanned spacecraft avionics systems. Similar considerations apply to commercial and military aircraft operating at high latitudes and altitudes near the atmospheric Pfotzer maximum. Even ground based computational and controls systems can be negatively affected by secondary particle showers at the Earth's surface, especially if the net target area of the sensitive electronic system components is large. Accumulation of both primary cosmic ray and secondary cosmic ray induced particle shower radiation dose is an important health and safety consideration for commercial or military air crews operating at high altitude/latitude and is also one of the most important factors presently limiting manned space flight operations beyond low-Earth orbit (LEO).

Atwell, William↗

IPHE Regulations Codes and Standards Working Group - Type IV COPV Round Robin Testing

This manuscript presents the results of a multi-lateral international activity intended to understand how to execute a cycle stress test as specified in a chosen standard (GTR, SAE, ISO, EIHP...). The purpose of this work was to establish a harmonized test method protocol to ensure that the same results would be achieved regardless of the testing facility. It was found that accurate temperature measurement of the working fluid is necessary to ensure the test conditions remain within the tolerances specified. Continuous operation is possible with adequate cooling of the working fluid but this becomes more demanding if the cycle frequency increases. Recommendations for future test system design and operation are presented.

Maes, M.↗

Force Limited Random Vibration Test of TESS Camera Mass Model

The Transiting Exoplanet Survey Satellite (TESS) is a spaceborne instrument consisting of four wide field-of-view-CCD cameras dedicated to the discovery of exoplanets around the brightest stars. As part of the environmental testing campaign, force limiting was used to simulate a realistic random vibration launch environment. While the force limit vibration test method is a standard approach used at multiple institutions including Jet Propulsion Laboratory (JPL), NASA Goddard Space Flight Center (GSFC), European Space Research and Technology Center (ESTEC), and Japan Aerospace Exploration Agency (JAXA), it is still difficult to find an actual implementation process in the literature. This paper describes the step-by-step process on how the force limit method was developed and applied on the TESS camera mass model. The process description includes the design of special fixtures to mount the test article for properly installing force transducers, development of the force spectral density using the semi-empirical method, estimation of the fuzzy factor (C2) based on the mass ratio between the supporting structure and the test article, subsequent validating of the C2 factor during the vibration test, and calculation of the C.G. accelerations using the Root Mean Square (RMS) reaction force in the spectral domain and the peak reaction force in the time domain.

Karlicek, Alexandra↗

Method for compression testing of composite materials at high strain rates

A method is presented for testing composite materials in compression at strain rates up to approximately 500 per s. The method uses a thin ring specimen (4 in. in diameter, 1 in. wide, six-eight plies thick) loaded dynamically by an external pressure pulse applied explosively through a liquid. Strains in the specimen and in a steel calibration ring are recoorded with a digital processing oscilloscope. Results are plotted by an x-y plotter in the form of a dynamic stress-strain curve. Data analysis is based on a numerical solution of the equation of motion. A computer program is used which involves smoothing and approximation of the strain magnitude, strain rate, and strain acceleration. Dynamic stress-strain curves obtained for 0-deg and 90-deg specimens of two graphite/epoxy composites are presented.

Daniel, I. M.↗

Long-time dynamic compatibility of two ethylene propylene elastomers with hydrazine

A test method is described for predicting the long-time survivability of elastomers in hydrazine under dynamic stressing conditions. The method selected is based upon the existence and approximate invariance of a 'physical property surface' relating the mechanical response of the elastomer in terms of stress, strain, time, and temperature. The property surface was generated for two selected elastomers (EPT-10 and AF-E-332). A novel carousel testing tank was designed to allow sequential testing of eight tensile specimens immersed in liquid hydrazine within a constant-temperature water bath. The test procedure and data reduction methods used to generate the property surface are described. The utility and validity of these results applied to fatigue and flexure loading to these elastomeric materials over long-time periods are discussed.

Coulbert, C. D.↗

Ignition of nonmetallic materials by impact of high-pressure oxygen. II - Evaluation of repeatability of pneumatic impact test

The gaseous oxygen pneumatic impact test is used to evaluate the suitability of nonmetallic materials for use in high-pressure oxygen systems. The test was evaluated by testing the reactivity of four materials over a range of impact pressures. The evaluation also investigated the effect of valve opening time and other test variables on the frequency of reaction. The variability of the data obtained for each test material was too large for the test method to be capable of distinguishing other than gross differences in the reactivity of materials. No relation was found between this variability and changes in valve opening time and other test variables. The materials studied were found to be unacceptable for use as reference standards. Because of the high variability of the test data, it is recommended that new methods be developed for evaluating the suitability of materials for use in high-pressure oxygen systems.

Schmidt, Naomi↗

Evaluation of a laboratory-developed multiplex real-time PCR assay for diagnosis of syphilis, herpes and chancroid genital ulcers in four public health laboratories in the USA

Objective To evaluate the field performance of a multiplex PCR (M-PCR) assay for detection of herpes simplex virus (HSV)-1 and HSV-2, Treponema pallidum ( T. pallidum ) and Haemophilus ducreyi ( H. ducreyi ) in genital ulcer disease (GUD) specimens. Methods GUD M-PCR was performed on 186 remnant specimens, previously collected for HSV testing, by four public health laboratories (PHLs) and the Laboratory Reference and Research Branch (LRRB) at the Centers for Disease Control and Prevention. The results from the PHLs were compared with those of LRRB, which served as the reference testing method, and percentage agreement was calculated. Results HSV was detected in 31 of 52 (59.6%), 20 of 40 (50%), 43 of 44 (97.7%) and 19 of 50 (38.0%) specimens from PHL1, PHL2, PHL3 and PHL4, respectively. There were seven discrepant results for HSV, and the overall percent agreement between the PHLs and the LRRB was 94%–100%, with a kappa value of 0.922, which demonstrates high agreement. T. pallidum was identified in 7 of 51 (13.7%) specimens from PHL1 with 94.1% agreement and in 2 of 40 (5.0%) specimens from PHL2 with 100% agreement. The LRRB identified three additional T. pallidum -positive specimens from PHL1. The kappa value (0.849) for T. pallidum testing suggests good agreement. Consistent with the LRRB results, no T. pallidum was detected in specimens from PHL3 and PHL4, and H. ducreyi was not detected at any of the study sites. Conclusions The GUD M-PCR assay performed well in four independent PHLs and 12 suspected syphilis cases were identified in this study. The M-PCR assay could provide improved diagnostic options for GUD infections in state and local PHLs.

Infectious Diseases↗

Simulation supported POD: Methodology and HFET validation case

Structure reliability guaranty requires prior evaluation of non destructive testing methods. The concept of Probability of Detection (POD) is generally used to quantitatively assess performances and reliability of testing operations. Such probabilistic approaches take into account the uncertainties that appear during inspections and that are responsible for the output variability. POD curve determination is based on costly and time consuming experimental campaigns. Increasing demand of NDT configurations requiring POD evaluation makes cost reduction of POD campaigns a major issue. A new trend is to apply simulation in the context of probabilistic approaches in order to replace some of the experimental data required to determine the POD with simulation results. This paper presents results of simulation based POD curves of a high frequency eddy current inspection procedure obtained with the new POD module of CIVA. The methodology used for describing uncertainties on the input simulation parameters is described and comparisons with experimental results are presented and discussed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Chloride and Fluoride Analysis Methods in Support of the Americium Recovery Program

ide determinations in AmO2. A relevant reference document is ASTM C698-10 Standard Test Methods for Chemical, Mass Spectrometric, and Spectrochemical Analysis of Nuclear-Grade Mixed Oxides ((U, Pu)O2). The main AmO2 analysis goals would be to meet the customers’ specifications with the minimum radiation dose to the analyst. Specifications any more stringent than the MOX program (Cl, F Sum ≤ 500 ppm (No one > 300 ppm)) will limit the methods under consideration. Presented here are the current analysis method along with a specific procedure modification for the analysis of Cl and F in support of the Americium Recovery Program.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A New Method for Incremental Testing of Finite State Machines

The automatic generation of test cases is an important issue for conformance testing of several critical systems. We present a new method for the derivation of test suites when the specification is modeled as a combined Finite State Machine (FSM). A combined FSM is obtained conjoining previously tested submachines with newly added states. This new concept is used to describe a fault model suitable for incremental testing of new systems, or for retesting modified implementations. For this fault model, only the newly added or modified states need to be tested, thereby considerably reducing the size of the test suites. The new method is a generalization of the well-known W-method and the G-method, but is scalable, and so it can be used to test FSMs with an arbitrarily large number of states.

Pedrosa, Lehilton Lelis Chaves↗

WE-A-210-01: Overview of Methods and Accreditation Updates

This presentation will focus on the present role of ultrasound medical physics in clinical practices. The first part of the presentation will provide an overview of ultrasound QC methodologies and testing procedures. A brief review of ultrasound phantoms utilized in these testing procedures will be presented. The second part of the presentation will summarize ultrasound imaging technical standards and professional guidelines by American College of Radiology (ACR), American Institute of Ultrasound in Medicine (AIUM), American Association of Physicists in Medicine (AAPM) and International Electrotechnical Commission (IEC). The current accreditation requirements by ACR and AIUM for ultrasound practices will be described and the practical aspects of implementing QC programs to be compliant with these requirements will be discussed. Learning Objectives: Achieve familiarity with common ultrasound QC test methods and ultrasound phantoms. Understand the coverage of the existing testing standards and professional guidelines on diagnostic ultrasound imaging. Learn what a medical physicist needs to know about ultrasound program accreditation and be able to implement ultrasound QC programs accordingly.

60 APPLIED LIFE SCIENCES↗

In situ spectroscopic analysis and quantification of [Tc(CO)3]+ in Hanford tank waste

A Pretreatment Protocol is demonstrated for the quantitative conversion and subsequent in situ spectroscopic analysis of non-pertechnetate [Tc(CO)3]+ in tank 241-AN-102 at the Hanford Site. This conversion technique is based on a test method demonstrated using [Re(CO)3]+ in simulated Hanford tank waste. The Protocol entails adding a real waste sample containing the non-pertechnetate [Tc(CO)3]+ species to a developer solution that facilitates the rapid, quantitative conversion of the non-emissive species to a luminescent species which can then be detected spectroscopically. Three AN-102 samples were tested by the standard addition method: (1) a 5 M Na adjusted sample, (2) a sample depleted 137Cs by resin column ion exchange, (3) and an acid-stripped column eluate. The concentrations of non-pertechnetate [Tc(CO)3]+ in these samples were 7.78 × 10-6 M, 6.53 × 10-7 M, and 2.46 × 10-6 M, respectively.

Branch, Shirmir D.↗

Design, fabrication and acceptance testing of a zero gravity whole body shower, volume 1

The effort to design whole body shower for the space station prototype is reported. Clothes and dish washer/dryer concepts were formulated with consideration given to integrating such a system with the overall shower design. Water recycling methods to effect vehicle weight savings were investigated and it was concluded that reusing wash and/or rinse water resulted in weight savings which were not sufficient to outweigh the added degree of hardware complexity. The formulation of preliminary and final designs for the shower are described. A detailed comparison of the air drag vs. vacuum pickup method was prepared that indicated the air drag concept results in more severe space station weight penalties; therefore, the preliminary system design was based on utilizing the vacuum pickup method. Tests were performed to determine the optimum methods of storing, heating and sterilizing the cleansing agent utilized in the shower; it was concluded that individual packages of pre-sterilized cleansing agent should be used. Integration features with the space station prototype system were defined and incorporated into the shower design as necessary.

Source record↗

Synthesis of greigite (Fe 3 S 4 ) particles via a hydrothermal method

Greigite (Fe 3 S 4 ) particles, with strong ferrimagnetic behavior, have been found to have desirable uses in the areas of biomedical and environmental applications. Size-dependent magnetic properties of greigite can play a crucial role in efficiency of its applications. This study reviews two synthetic approaches to producing such particles. The methods tested within this study include a coprecipitation synthesis and a hydrothermal process. While the coprecipitation method proved to be ineffective at producing greigite, the hydrothermal process showed promise after consistently producing greigite. For the hydrothermal process, the effects of synthesis time, autoclave atmosphere, and polyvinylpyrrolidone (PVP) addition as a capping agent to control particle growth were investigated using X-ray diffractometry (XRD) with Rietveld refinement, vibrating sample magnetometry (VSM), and scanning electron microscopy (SEM). The results show that, while pyrite (FeS2) forms as an impurity phase, increasing the synthesis time up to 18 hours increases the greigite fraction up to 70 wt% and saturation magnetization up to ~ 35 emu/g for the powder synthesized in argon. The SEM micrographs of this sample reveal a mean greigite particle size of ~ 700 nm. It was found that adding PVP brings about a much more uniform microstructure of agglomerated plate-shape particles with nano-sized features.

36 MATERIALS SCIENCE↗

A Generalized Subspace Least Mean Square Method for High-resolution Accurate Estimation of Power System Oscillation Modes

A Generalized Subspace-Least Mean Square (GSLMS) method is presented for accurate and robust estimation of oscillation modes from exponentially damped power system signals. The method is based on orthogonality of signal and noise eigenvectors of the signal autocorrelation matrix. Performance of the proposed method is evaluated using Monte Carlo simulation and compared with Prony method. Test results show that the GSLMS is highly resilient to noise and significantly dominates Prony method in tracking power system modes under noisy environments.

Zhang, Peng↗

WE-DE-207A-00: Advances in Image-Guided Neurointerventions-Clinical Pull and Technology Push

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

WE-DE-207A-01: Parallels in the Evolution of X-Ray Angiographic Systems and Devices Used for Minimally Invasive Endovascular Therapy

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗