Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Systematic error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Clinical Experience and Evaluation of Patient Treatment Verification With a Transit Dosimeter

Purpose: To prospectively evaluate a protocol for transit dosimetry on a patient population undergoing intensity modulated radiation therapy (IMRT) and to assess the issues in clinical implementation of electronic portal imaging devices (EPIDs) for treatment verification. Methods and Materials: Fifty-eight patients were enrolled in the study. Amorphous silicon EPIDs were calibrated for dose and used to acquire images of delivered fields. Measured EPID dose maps were back-projected using the planning computed tomographic (CT) images to calculate dose at prespecified points within the patient and compared with treatment planning system dose offline using point dose difference and point γ analysis. The deviation of the results was used to inform future action levels. Results: Two hundred twenty-five transit images were analyzed, composed of breast, prostate, and head and neck IMRT fields. Patient measurements demonstrated the potential of the dose verification protocol to model dose well under complex conditions: 83.8% of all delivered beams achieved the initial set tolerance level of Δ{sub D} of 0 ± 5 cGy or %Δ{sub D} of 0% ± 5%. Importantly, the protocol was also sensitive to anatomic changes and spotted that 3 patients from 20 measured prostate patients had undergone anatomic change in comparison with the planning CT. Patient data suggested an EPID-reconstructed versus treatment planning system dose difference action level of 0% ± 7% for breast fields. Asymmetric action levels were more appropriate for inversed IMRT fields, using absolute dose difference (−2 ± 5 cGy) or summed field percentage dose difference (−6% ± 7%). Conclusions: The in vivo dose verification method was easy to use and simple to implement, and it could detect patient anatomic changes that impacted dose delivery. The system required no extra dose to the patient or treatment time delay and so could be used throughout the course of treatment to identify and limit systematic and random errors in dose delivery for patient groups.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stochastic solution of population balance equations for reactor networks

This work presents a sequential modular approach to solve a generic network of reactors with a population balance model using a stochastic numerical method. Full-coupling to the gas-phase is achieved through operator-splitting. The convergence of the stochastic particle algorithm in test networks is evaluated as a function of network size, recycle fraction and numerical parameters. These test cases are used to identify methods through which systematic and statistical error may be reduced, including by use of stochastic weighted algorithms. The optimal algorithm was subsequently used to solve a one-dimensional example of silicon nanoparticle synthesis using a multivariate particle model. This example demonstrated the power of stochastic methods in resolving particle structure by investigating the transient and spatial evolution of primary polydispersity, degree of sintering and TEM-style images. Highlights: •An algorithm is presented to solve reactor networks with a population balance model. •A stochastic method is used to solve the population balance equations. •The convergence and efficiency of the reported algorithms are evaluated. •The algorithm is applied to simulate silicon nanoparticle synthesis in a 1D reactor. •Particle structure is reported as a function of reactor length and time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Best practices in evaluation of the magnetocaloric effect from bulk magnetization measurements

Conventional magnetometry is irreplaceable in evaluating bulk magnetization of materials over broad temperature and field ranges. The technique is also effective in quantifying hysteresis that may be associated with magnetic and structural phase transitions that occur during the magnetizing/demagnetizing cycling, and the derived magnetic field-induced isothermal entropy change – one of the most important properties in the field of magnetocalorics. Both systematic and random errors present during the measurements of magnetization, however, may lead to erroneous conclusions. Using two well-known materials – elemental Gd and intermetallic Gd 5 Si 2 Ge 2 as examples, we consider best practices in performing reliable and rapid magnetization measurements for proper characterization of magnetocaloric properties.

36 MATERIALS SCIENCE↗

A Practical Approach to Wave Function Propagation, Hopping Probabilities, and Time Steps in Surface Hopping Calculations

We compare several established approaches for propagating wave functions and calculating hopping probabilities within the fewest switches surface hopping (FSSH) algorithm for difficult cases with many electronic states and many trivial crossings. If only a single time step (Δt c ) is employed, we find that no published approach can accurately capture the dynamics correctly unless Δt c → 0 (which is not computationally feasible). If multiple time steps are employed, for a fixed classical time step (Δt c ), a robust scheme can be found for dynamically choosing quantum time steps (δt q1 and δt q2 ) and calculating hopping probabilities so that one can systematically reduce all errors and achieve maximally efficient accuracy; scattering calculations confirm that one can choose a fairly large classical time step. Furthermore, the robust scheme presented here uses both the “local diabatic” and adiabatic interpolation and thus borrows elements from both the Granucci/Persico and Meek/Levine algorithms. Our findings should be broadly applicable in the future.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Catalight─An Open-Source Automated Photocatalytic Reactor Package Illustrated through Plasmonic Acetylene Hydrogenation

An open-source and modular Python package, Catalight, is developed and demonstrated to automate (photo)catalysis measurements. (Photo)catalysis experiments require studying several parameters to evaluate performance, including the temperature, gas flow rate and composition, illumination power, and spectral profile. Catalight orchestrates measurements over this complicated parameter space and systematically stores, analyzes, and visualizes the results. To showcase the capabilities of Catalight, we perform an automated apparent activation barrier measurement of acetylene hydrogenation over a plasmonic AuPd catalyst on an Al 2 O 3 support, simultaneously varying laser power, wavelength, and temperature in a multiday experiment controlled by a simple Python script. Our chemical results unexpectedly show an increased activation barrier upon light excitation, contrary to previous findings for other plasmonic reactions and catalysts. We show that the reaction rate order with respect to both acetylene and hydrogen remains unchanged upon illumination, suggesting that molecular surface coverage is not changed by light. By analyzing the inhomogeneity of the laser-induced heating, we attribute these results to a partial photothermal effect combined with a photochemical/hot electron-driven mechanism. In conclusion, our findings highlight the capabilities of a new experiment automation tool; explore the photocatalytic mechanism for an industrially relevant reaction; and identify systematic sources of error in canonical photocatalysis experimental procedures.

Catalysts↗

COSMOGRAIL: the COSmological MOnitoring of GRAvItational Lenses: XVI. Time delays for the quadruply imaged quasar DES J0408–5354 with high-cadence photometric monitoring* [COSMOGRAIL XVI: Time delays for the quadruply imaged quasar DES J0408–5354 with high-cadence photometric monitoring]

Here, we present time-delay measurements for the new quadruple imaged quasar DES J0408–5354, the first quadruple imaged quasar found in the Dark Energy Survey (DES). Our result is made possible by implementing a new observational strategy using almost daily observations with the MPIA 2.2 m telescope at La Silla observatory and deep exposures reaching a signal-to-noise ratio of about 1000 per quasar image. This data qualityallows us to catch small photometric variations (a few mmag rms) of the quasar, acting on temporal scales much shorter than microlensing, and hence making the time delay measurement very robust against microlensing. In only seven months we very accurately measured one of the time delays in DES J0408–5354: Δt(AB) = –112.1 ± 2.1 days (1.8%) using only the MPIA 2.2 m data. In combination with data taken with the 1.2 m Euler Swiss telescope, we also measured two delays involving the D component of the system Δt(AD) = –155.5 ± 12.8 days (8.2%) and Δt(BD) = –42.4 ± 17.6 days (41%), where all the error bars include systematics. Turning these time delays into cosmological constraints will require deep Hubble Space Telescope (HST) imaging or ground-based adaptive optics (AO), and information on the velocity field of the lensing galaxy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Crosstalk elimination in the detection of dual-beam optical tweezers by spatial filtering

In dual-beam optical tweezers, the accuracy of position and force measurements is often compromised by crosstalk between the two detected signals, this crosstalk leading to systematic and significant errors on the measured forces and distances. This is true both for dual-beam optical traps where the splitting of the two traps is done by polarization optics and for dual optical traps constructed by other methods, e.g., holographic tweezers. If the two traps are orthogonally polarized, most often crosstalk is minimized by inserting polarization optics in front of the detector; however, this method is not perfect because of the de-polarization of the trapping beam introduced by the required high numerical aperture optics. Here we present a simple and easy-to-implement method to efficiently eliminate crosstalk. The method is based on spatial filtering by simply inserting a pinhole at the correct position and is highly compatible with standard back focal plane photodiode based detection of position and force. Our spatial filtering method reduces crosstalk up to five times better than polarization filtering alone. The effectiveness is dependent on pinhole size and distance between the traps and is here quantified experimentally and reproduced by theoretical modeling. The method here proposed will improve the accuracy of force-distance measurements, e.g., of single molecules, performed by dual-beam optical traps and hence give much more scientific value for the experimental efforts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CRITICAL EVALUATION OF MAGNETIC FIELD DETECTIONS REPORTED FOR PULSATING B-TYPE STARS IN LIGHT OF ESPaDOnS, NARVAL, AND REANALYZED FORS1/2 OBSERVATIONS

Recent spectropolarimetric studies of seven slowly pulsating B (SPB) and {beta} Cep stars have suggested that photospheric magnetic fields are more common in B-type pulsators than in the general population of B stars, suggesting a significant connection between magnetic and pulsational phenomena. We present an analysis of new and previously published spectropolarimetric observations of these stars. New Stokes V observations obtained with the high-resolution ESPaDOnS and Narval instruments confirm the presence of a magnetic field in one of the stars ({epsilon} Lup), but find no evidence of magnetism in five others. A re-analysis of the published longitudinal field measurements obtained with the low-resolution FORS1/2 spectropolarimeters finds that the measurements of all stars show more scatter from zero than can be attributed to Gaussian noise, suggesting the presence of a signal and/or systematic underestimation of error bars. Re-reduction and re-measurement of the FORS1/2 spectra from the ESO archive demonstrates that small changes in reduction procedure lead to substantial changes in the inferred longitudinal field, and substantially reduces the number of field detections at the 3{sigma} level. Furthermore, we find that the published periods are not unique solutions to the time series of either the original or the revised FORS1/2 data. We conclude that the reported field detections, proposed periods, and field geometry models for {alpha} Pyx, 15 CMa, 33 Eri, and V1449 Aql are artifacts of the data analysis and reduction procedures, and that magnetic fields at the reported strength are no more common in SPB/{beta} Cep stars than in the general population of B stars.

79 ASTRONOMY AND ASTROPHYSICS↗

MEASURING BARYON ACOUSTIC OSCILLATIONS ON 21 cm INTENSITY FLUCTUATIONS AT MODERATE REDSHIFTS

After reionization, emission in the 21 cm hyperfine transition provides a direct probe of neutral hydrogen distributed in galaxies. Different from galaxy redshift surveys, observation of baryon acoustic oscillations in the cumulative 21 cm emission may offer an attractive method for constraining dark energy properties at moderate redshifts. Keys to this program are techniques to extract the faint cosmological signal from various contaminants, such as detector noise and continuum foregrounds. In this paper, we investigate the possible systematic and statistical errors in the acoustic scale estimates using ground-based radio interferometers. Based on the simulated 21 cm interferometric measurements, we analyze the performance of a Fourier-space, light-of-sight algorithm in subtracting foregrounds, and further study the observing strategy as a function of instrumental configurations. Measurement uncertainties are presented from a suite of simulations with a variety of parameters, in order to have an estimate of what behaviors will be accessible in the future generation of hydrogen surveys. We find that 10 separate interferometers, each of which contains {approx}300 dishes, observing an independent patch of the sky and producing an instantaneous field of view (FOV) of {approx}100 deg{sup 2}, can be used to make a significant detection of acoustic features over a period of a few years. Compared to optical surveys, the broad bandwidth, wide FOV, and multi-beam observation are all unprecedented capabilities of low-frequency radio experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Dark Energy Survey Identification of A Low-Mass Active Galactic Nucleus at Redshift 0.823 from Optical Variability

We report the identification of a low-mass active galactic nucleus (AGN), DES J0218−0430, in a redshift z = 0.823 galaxy in the Dark Energy Survey (DES) Supernova field. We select DES J0218−0430 as an AGN candidate by characterizing its long-term optical variability alone based on DES optical broad-band light curves spanning over 6 yr. An archival optical spectrum from the fourth phase of the Sloan Digital Sky Survey shows both broad Mg ii and broad H β lines, confirming its nature as a broad-line AGN. Archival XMM–Newton X-ray observations suggest an intrinsic hard X-ray luminosity of |$L_{{\rm 2-12\, keV}}\approx 7.6\pm 0.4\times 10^{43}$| erg s^−1, which exceeds those of the most X-ray luminous starburst galaxies, in support of an AGN driving the optical variability. Based on the broad H β from SDSS spectrum, we estimate a virial black hole (BH) mass of M_• ≈ 10^6.43–10^6.72 M_⊙ (with the error denoting the systematic uncertainty from different calibrations), consistent with the estimation from OzDES, making it the lowest mass AGN with redshift > 0.4 detected in optical. We estimate the host galaxy stellar mass to be M_* ≈ 10^10.5 ± 0.3 M_⊙ based on modelling the multiwavelength spectral energy distribution. DES J0218−0430 extends the M_•–M_* relation observed in luminous AGNs at z ∼ 1 to masses lower than being probed by previous work. Our work demonstrates the feasibility of using optical variability to identify low-mass AGNs at higher redshift in deeper synoptic surveys with direct implications for the upcoming Legacy Survey of Space and Time at Vera C. Rubin Observatory.

79 ASTRONOMY AND ASTROPHYSICS↗

The clustering of the SDSS-IV extended Baryon Oscillation Spectroscopic Survey DR14 quasar sample: structure growth rate measurement from the anisotropic quasar power spectrum in the redshift range 0.8 < z < 2.2

We analyse the clustering of the Sloan Digital Sky Survey IV extended Baryon Oscillation Spectroscopic Survey Data Release 14 quasar sample (DR14Q).We measure the redshift space distortions using the power-spectrum monopole, quadrupole, and hexadecapole inferred from 148 659 quasars between redshifts 0.8 and 2.2, covering a total sky footprint of 2112.9 deg 2 . We constrain the logarithmic growth of structure times the amplitude of dark matter density fluctuations, fσ 8 , and the Alcock–Paczynski dilation scales that allow constraints to be placed on the angular diameter distance D A (z) and the Hubble H(z) parameter. At the effective redshift of z eff = 1.52, fσ 8 (z eff ) = 0.420 ± 0.076, H(z eff ) = [162 ± 12] (r$fid\atop{s}$ /r s ) kms -1 Mpc -1 , and DA(z eff ) = [1.85 ± 0.11] × 10 3 (r s/ r$fid\atop{s}$) Mpc, where r s is the comoving sound horizon at the baryon drag epoch and the superscript ‘fid’ stands for its fiducial value. The errors take into account the full error budget, including systematics and statistical contributions. These results are in full agreement with the current Λ-Cold Dark Matter cosmological model inferred from Planck measurements. Finally, we compare our measurements with other eBOSS companion papers and find excellent agreement, demonstrating the consistency and complementarity of the different methods used for analysing the data.

79 ASTRONOMY AND ASTROPHYSICS↗

Cohesion and excitations of diamond-structure silicon by quantum Monte Carlo: Benchmarks and control of systematic biases

We have carried out quantum Monte Carlo (QMC) calculations of silicon crystal focusing on the accuracy and systematic biases that affect the electronic structure characteristics. The results show that 64 and 216 atom supercells provide an excellent consistency for extrapolated energies per atom in the thermodynamic limit for ground, excited, and ionized states. We have calculated the ground state cohesion energy with both systematic and statistical errors below ≈ 0.05 eV. The ground state exhibits a fixed-node error of only 1.3(2)% of the correlation energy, suggesting an unusually high accuracy of the corresponding single-reference trial wave function. We obtain a very good agreement between optical and quasiparticle gaps that affirms the marginal impact of excitonic effects. Our most accurate results for band gaps differ from the experiments by about 0.2 eV. This difference is assigned to a combination of residual finite-size and fixed-node errors. In conclusion, we have estimated the crystal Fermi level referenced to vacuum that enabled us to calculate the edges of valence and conduction bands in agreement with experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cosmology with photometric weak lensing surveys: Constraints with redshift tomography of convergence peaks and moments

Weak gravitational lensing is becoming a mature technique for constraining cosmological parameters, and future surveys will be able to constrain the dark energy equation of state w. When analyzing galaxy surveys, redshift information has proven to be a valuable addition to angular shear correlations. We forecast parameter constraints on the triplet (Ω m ,w,σ 8 ) for a LSST-like photometric galaxy survey, using tomography of the shear-shear power spectrum, convergence peak counts and higher convergence moments. Here we find that redshift tomography with the power spectrum reduces the area of the 1σ confidence interval in (Ω m ,w) space by a factor of 8 with respect to the case of the single highest redshift bin. We also find that adding non-Gaussian information from the peak counts and higher-order moments of the convergence field and its spatial derivatives further reduces the constrained area in (Ω m ,w) by factors of 3 and 4, respectively. When we add cosmic microwave background parameter priors from Planck to our analysis, tomography improves power spectrum constraints by a factor of 3. Adding moments yields an improvement by an additional factor of 2, and adding both moments and peaks improves by almost a factor of 3 over power spectrum tomography alone. We evaluate the effect of uncorrected systematic photometric redshift errors on the parameter constraints. In conclusion, we find that different statistics lead to different bias directions in parameter space, suggesting the possibility of eliminating this bias via self-calibration.

79 ASTRONOMY AND ASTROPHYSICS↗

Structure Factors of Neutron Matter at Finite Temperature

Here, we compute continuum and infinite volume limit extrapolations of the structure factors of neutron matter at finite temperature and density. Using a lattice formulation of leading-order pionless effective field theory, we compute the momentum dependence of the structure factors at finite temperature and at densities beyond the reach of the virial expansion. The Tan contact parameter is computed and the result agrees with the high momentum tail of the vector structure factor. All errors, statistical and systematic, are controlled for. This calculation is a first step towards a model-independent understanding of the linear response of neutron matter at finite temperature.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of Compton Scattering at MAMI for the Extraction of the Electric and Magnetic Polarizabilities of the Proton

A precise measurement of the differential cross sections dσ/dΩ and the linearly polarized photon beam asymmetry Σ 3 for Compton scattering on the proton below pion threshold has been performed with a tagged photon beam and almost 4π detector at the Mainz Microtron. The incident photons were produced by the recently upgraded Glasgow-Mainz photon tagging facility and impinged on a cryogenic liquid hydrogen target, with the scattered photons detected in the Crystal Ball/TAPS setup. Using the highest statistics Compton scattering data ever measured on the proton along with two effective field theories (both covariant baryon and heavy-baryon) and one fixed-t dispersion relation model, constraining the fits with the Baldin sum rule, we have obtained the proton electric and magnetic polarizabilities with unprecedented precision: α E1 = 10.99 ± 0.16 ± 0.47 ± 0.17 ± 0.34, β M1 = 3.14 ± 0.21 ± 0.24 ± 0.20 ± 0.35; in units of 10 -4 fm 3 where the errors are statistical, systematic, spin polarizability dependent, and model dependent.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Tolerance Studies of the Mu2e Solenoid System

The muon-to-electron conversion experiment at Fermilab is designed to explore charged lepton flavor violation. It is composed of three large superconducting solenoids, namely, the production solenoid, the transport solenoid, and the detector solenoid. Each subsystem has a set of field requirements. Tolerance sensitivity studies of the magnet system were performed with the objective of demonstrating that the present magnet design meets all the field requirements. Systematic and random errors were considered on the position and alignment of the coils. The study helps to identify the critical sources of errors and which are translated to coil manufacturing and mechanical support tolerances.

43 PARTICLE ACCELERATORS↗

SU-E-T-425: Spherical Dose Distributions for Radiosurgery Using a Standardized MLC Plan

Purpose: To investigate a standardized MLC treatment plan to generate small spherical dose distributions. Methods: The static virtual cone plan comprised six table positions with clockwise and counterclockwise arcs having collimator angles 45 and 135 degrees, respectively, at each position. The central two leaves of a 2.5 mm leaf width MLC were set to a constant gap. Control points were weighted proportional to the sine of the gantry angle. Plans were created for the 10 MV flattening-filter-free beam of a TrueBeam STx (Varian Medical Systems) with gaps of 1, 1.5, 2, and 3 mm and were delivered to a phantom containing radiochromic film. Dose was calculated using the Eclipse AAA (Varian Medical Systems). A dynamic plan in which the table and gantry moved simultaneously with 1.5 mm gap was also created and delivered using the TrueBeam developer mode. Results: The full-width-half-max (FWHM) varied with leaf gap, ranging from 5.2 to 6.2 mm. Calculated FWHM was smaller than measured by 0.7 mm for the 1 mm gap and ≤ 0.4 mm for the larger gaps. The measured-to-calculated dose ratio was 0.93, 0.96, 1.01, and 0.99 for 1 mm, 1.5 mm, 2 mm, and 3 mm gaps, respectively. The dynamic results were the same as the static. The position deviations between the phantom target position and the center of the dose distribution were < 0.4 mm. Conclusion: The virtual cone can deliver spherical dose distributions suitable for radio surgery of small targets such as the trigeminal nerve. The Eclipse AAA accurately calculates the expected dose, particularly for leaf gap ≥ 1.5 mm. The measured dose distribution is slightly larger than the calculation, which is likely due to systematic leaf position error, isocenter variation due to gantry sag and table eccentricity, and inaccuracy in MLC leaf end modeling.

60 APPLIED LIFE SCIENCES↗

WE-AB-209-08: Novel Beam-Specific Adaptive Margins for Reducing Organ-At-Risk Doses

Purpose: Current practice of using 3D margins in radiotherapy with high-energy photon beams provides larger-than-required target coverage. According to the photon depth-dose curve, target displacements in beam direction result in minute changes in dose delivered. We exploit this behavior by generating margins on a per-beam basis which simultaneously account for the relative distance of the target and adjacent organs-at-risk (OARs). Methods: For each beam, we consider only geometrical uncertainties of the target location perpendicular to beam direction. By weighting voxels based on its proximity to an OAR, we generate adaptive margins that yield similar overall target coverage probability and reduced OAR dose-burden, at the expense of increased target volume. Three IMRT plans, using 3D margins and 2D per-beam margins with and without adaptation, were generated for five prostate patients with a prescription dose Dpres of 78Gy in 2Gy fractions using identical optimisation constraints. Systematic uncertainties of 1.1, 1.1, 1.5mm in the LR, SI, and AP directions, respectively, and 0.9, 1.1, 1.0mm for the random uncertainties, were assumed. A verification tool was employed to simulate the effects of systematic and random errors using a population size of 50,000. The fraction of the population that satisfies or violates a given DVH constraint was used for comparison. Results: We observe similar target coverage across all plans, with at least 97.5% of the population meeting the D98%>95%Dpres constraint. When looking at the probability of the population receiving D5<70Gy for the rectum, we observed median absolute increases of 23.61% (range, 2.15%–27.85%) and 6.97% (range, 0.65%–17.76%) using per-beam margins with and without adaptation, respectively, relative to using 3D margins. Conclusion: We observed sufficient and similar target coverage using per-beam margins. By adapting each per-beam margin away from an OAR, we can further reduce OAR dose without significantly lowering target coverage probability by irradiating more less-important tissues. This work is supported by Cancer Research UK under Programme C33589/A19908. Research at ICR is also supported by Cancer Research UK under Programme C33589/A19727 and NHS funding to the NIHR Biomedical Research Centre at RMH and ICR.

07 ISOTOPE AND RADIATION SOURCES↗