Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Short circuiting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

The suppression of charged-particle-induced noise in infrared detectors

A d.c.-coupled transimpedance amplifier/pulse suppression circuit designed to remove charged-particle-induced noise from infrared detectors is described. Noise spikes produced by single particle events are large and have short rise times, and can degrade the performance of an infrared detector in moderate radiation environments. The use of the suppression circuit improves the signal-to-noise ratio by a factor of 1.6:1, which corresponds to a reduction in required observing time by a factor of about 2.6.

Houck, J. R.↗

A 311-GHz Fundamental Oscillator Using InP HBT Technology

This oscillator uses a single-emitter 0.3- m InP heterojunction bipolar transistor (HBT) device with maximum frequency of oscillation (fmax) greater than 500 GHz. Due to high conductor and substrate losses at submillimeterwave frequencies, a primary challenge is to efficiently use the intrinsic device gain. This was done by using a suitable transmission-line media and circuit topology. The passive components of the oscillator are realized in a twometal process with benzocyclobutene (BCB) used as the primary transmission line dielectric. The circuit was designed using microstrip transmission lines. The oscillator is implemented in a common-base topology due to its inherent instability, and the design includes an on-chip resonator, outputmatching circuitry, and an injection-locking port, the port being used to demonstrate the injection-locking prin ciple. A free-running frequency of 311.6 GHz has been measured by down-converting the signal. Ad di tionally, injection locking has been successfully demonstrated with up to 17.8 dB of injection-locking gain. The injection-locking reference signal is generated using a 2 20 GHz frequency synthesizer, followed by a doubler, active tripler, a W-band amplifier, and then a passive tripler. Therefore, the source frequency is multiplied 18 times to obtain a signal above 300 GHz that can be used to injection lock the oscillator. Measurement shows that injection locking has improved the phase noise of the oscillator and can be also used for synchronizing a series of oscillators. A signal conductor is implemented near the BCP -InP interface and the topside of the BCB layer is fully metallized as a signal ground. Because the fields are primarily constrained in the lower permittivity BCB region, this type of transmission line is referred to as an inverted microstrip. In addition, both common-emitter and commonbase circuits were investigated to determine optimum topology for oscillator design. The common -base topology required smaller amount of feedback than the common-emitter design, therefore preserving device gain, and was chosen for the oscillator design. The submillimeter-wave region offers several advantages for sensors and communication systems, such as high resolution and all-weather imaging due to the short-wavelength, and improved communication speeds by access to greater frequency bandwidth. This oscillator circuit is a prototype of the first HBT oscillator operating above 300 GHz. Additional development is necessary to increase the output power of the circuit for radar and imaging applications.

Gaier, Todd↗

Biasable Subharmonic Membrane Mixer for 520 to 600 GHz

The figure shows a biasable subharmonic mixer designed to operate in the frequency range from 520 to 600 GHz. This mixer is a prototype of low-power mixers needed for development of wideband, high-resolution spectrometers for measuring spectra of molecules in the atmospheres of Earth, other planets, and comets in the frequency range of 400 to 700 GHz. Three considerations dictated the main features of the design: It is highly desirable to operate the spectrometers at or slightly below room temperature. This consideration is addressed by choosing Schottky diodes as the frequency-mixing circuit elements because of all mixer diodes, Schottky diodes are the best candidates for affording sufficient sensitivity at or slightly below room-temperature range. The short wavelengths in the intended operating-frequency range translate to stringent requirements for precision of fabrication and assembly of the circuits; these requirements are even more stringent for wide-bandwidth circuits. This consideration is addressed in two ways: (1) As much as possible of the mixer circuitry is fabricated in the form of a monolithic integrated circuit on a GaAs membrane, employing a modified version of a process used previously to fabricate a non-subharmonic mixer for a frequency of 2.5 THz and frequency multipliers for frequencies up to 2 THz. (2) The remainder of the circuitry is precision machined into a waveguide block that holds the GaAs integrated circuit.

Schlecht, Erich↗

Universal Spreading of Conditional Mutual Information in Noisy Random Circuits

For this work, we study the evolution of conditional mutual information (CMI) in generic open quantum systems, focusing on one-dimensional random circuits with interspersed local noise. Unlike in noiseless circuits, where CMI spreads linearly while being bounded by the light cone, we find that noisy random circuits with an error rate 𝑝 exhibit superlinear propagation of CMI, which diverges far beyond the light cone at a critical circuit depth 𝑡 𝑐 ∝ 𝑝 −1 . We demonstrate that the underlying mechanism for such rapid spreading is the combined effect of local noise and a scrambling unitary, which selectively removes short-range correlations while preserving long-range correlations. To analytically capture the dynamics of CMI in noisy random circuits, we introduce a coarse-graining method, and we validate our theoretical results through numerical simulations. Furthermore, we identify a universal scaling law governing the spreading of CMI.

decoherence↗

Variational fast forwarding for quantum simulation beyond the coherence time

Abstract Trotterization-based, iterative approaches to quantum simulation (QS) are restricted to simulation times less than the coherence time of the quantum computer (QC), which limits their utility in the near term. Here, we present a hybrid quantum-classical algorithm, called variational fast forwarding (VFF), for decreasing the quantum circuit depth of QSs. VFF seeks an approximate diagonalization of a short-time simulation to enable longer-time simulations using a constant number of gates. Our error analysis provides two results: (1) the simulation error of VFF scales at worst linearly in the fast-forwarded simulation time, and (2) our cost function’s operational meaning as an upper bound on average-case simulation error provides a natural termination condition for VFF. We implement VFF for the Hubbard, Ising, and Heisenberg models on a simulator. In addition, we implement VFF on Rigetti’s QC to demonstrate simulation beyond the coherence time. Finally, we show how to estimate energy eigenvalues using VFF.

97 MATHEMATICS AND COMPUTING↗

Rhythm

Rhythm is a small Python framework that automates Cadence Spectre simulations from the command line. Instead of creating an ADE testbench, you'll write a Rhythm Recipe, a short, readable Python script that contains each step needed to test your circuit from setting up libraries and stimulus waveforms to setting up analyses and reading the results (in Rhythm, these steps are called stages). Need to run more than one simulation? Use a Rhythm Campaign to easily sweep across corners and test conditions with a live dashboard and multithreading support.

Quinn, Adam [Fermi National Accelerator Laboratory↗

Parallel VLSI architecture emulation and the organization of APSA/MPP

The Applicative Programming System Architecture (APSA) combines an applicative language interpreter with a novel parallel computer architecture that is well suited for Very Large Scale Integration (VLSI) implementation. The Massively Parallel Processor (MPP) can simulate VLSI circuits by allocating one processing element in its square array to an area on a square VLSI chip. As long as there are not too many long data paths, the MPP can simulate a VLSI clock cycle very rapidly. The APSA circuit contains a binary tree with a few long paths and many short ones. A skewed H-tree layout allows every processing element to simulate a leaf cell and up to four tree nodes, with no loss in parallelism. Emulation of a key APSA algorithm on the MPP resulted in performance 16,000 times faster than a Vax. This speed will make it possible for the APSA language interpreter to run fast enough to support research in parallel list processing algorithms.

Odonnell, John T.↗

Pulse width dependence of magnetic field generation using laser-powered capacitor coils

Megagauss magnetic fields were generated by a current flowing through a U-shaped coil connecting two parallel copper foils. Two kJ-class lasers at various pulse widths from 2 ns to 9.9 ns passed through holes in the front foil and were focused on the back foil with an intensity of ~1.7×10 16 W/cm 2 . The coil current and resulting magnetic fields were characterized using ultrafast proton radiography, timed at the end of the laser pulses. Additionally, the measurements show that magnetic field strength decays with increasing laser pulse width. A lumped-circuit model was developed and showed consistency with the experimental measurements, demonstrating an ion shorting effect: as the ion current neutralizes the electron current contribution to interplate voltage, the coil current peaks on a timescale close to the ion transit time t i = d/v ion . FLASH simulations of the coil current are performed, and the calculated resistance values are used to constrain ion speed as a function of hot electron temperature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advances in Submillimeter Semiconductor-Based Device Designs and Processes

Planar submillimeter circuits are slowly replacing whisker-contacted devices at frequencies above 100 GHz, but in many cases the size constraints brought on by the short wavelengths associated with high frequency operation have not been adequeately addressed. Also, reproducibility becomes more important as we make the transition from tunable, whisker-based circuits to more monolithic designs. We are continuing to develop new circuites with more reproducible characteristics.

Submillimeter Semiconductor↗

Electrochemical Deposition with Redox Replacement of Lanthanum with Uranium in Molten LiCl-KCl

Electrochemical recovery of dilute concentrations of actinides from spent nuclear fuel would reduce the longevity of storing high-level nuclear waste. Electrochemical deposition with redox replacement (EDRR) is used in a molten salt medium for the selective electrochemical recovery of uranium in the presence of excess concentrations of lanthanum. In each EDRR cycle, after a short electrodeposition pulse, the deposited lanthanum is spontaneously replaced by uranium at open circuit. After repeated cycles, uranium metal was obtained on a tungsten electrode immersed in LiCl-KCl melt that contained 1 wt.% lanthanum chloride – 0.15 wt.% uranium 4+ chloride. Here, scanning electron microscopy and energy dispersive X-ray spectroscopy analysis revealed uranium particles approximately 0.5 - 1 μm with well-defined rectangular shapes; and with 20 – 60 times more uranium recovered on the surface of the electrode than lanthanum.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Radiation Testing and Evaluation Issues for Modern Integrated Circuits

Abstract. Changes in modern integrated circuit (IC) technologies have modified the way we approach and conduct radiation tolerance and testing of electronics. These changes include scaling of geometries, new materials, new packaging technologies, and overall speed and device complexity challenges. In this short course section, we will identify and discuss these issues as they impact radiation testing, modeling, and effects mitigation of modern integrated circuits. The focus will be on CMOS-based technologies, however, other high performance technologies will be discussed where appropriate. The effects of concern will be: Single-Event Effects (SEE) and steady state total ionizing dose (TID) IC response. However, due to the growing use of opto-electronics in space systems issues concerning displacement damage testing will also be considered. This short course section is not intended to provide detailed "how-to-test" information, but simply provide a snapshot of current challenges and some of the approaches being considered.

LaBel, Kenneth A.↗

Peak holding circuit for extremely narrow pulses

An improved pulse stretching circuit comprising: a high speed wide-band amplifier connected in a fast charge integrator configuration; a holding circuit including a capacitor connected in parallel with a discharging network which employs a resistor and an FET; and an output buffer amplifier. Input pulses of very short duration are applied to the integrator charging the capacitor to a value proportional to the input pulse amplitude. After a predetermined period of time, conventional circuitry generates a dump pulse which is applied to the gate of the FET making a low resistance path to ground which discharges the capacitor. When the dump pulse terminates, the circuit is ready to accept another pulse to be stretched. The very short input pulses are thus stretched in width so that they may be analyzed by conventional pulse height analyzers.

Oneill, R. W.↗

Heart rate, multiple body temperature, long-range and long-life telemetry system for free-ranging animals

The design details and rationale for a versatile, long-range, long-life telemetry data acquisition system for heart rates and body temperatures at multiple locations from free-ranging animals are presented. The design comprises an implantable transmitter for short to medium range transmission, a receiver retransmitter collar to be worn for long-range transmission, and a signal conditioner interface circuit to assist in signal discrimination and demodulation of receiver or tape-recorded audio outputs. Implanted electrodes are used to obtain an ECG, from which R-wave characteristics are selected to trigger a short RF pulse. Pulses carrying heart rate information are interrupted periodically by a series of pulse interval modulated RF pulses conveying temperature information sensed at desired locations by thermistors. Pulse duration and pulse sequencing are used to discriminate between heart rate and temperature pulses as well as radio frequency interference. The implanted transmitter may be used alone for medium and short-range tracking, or with a receiver-transmitter collar that employs commercial tracking equipment for transmissions of up to 12 km. A system prototype has been tested on a dog.

Lund, G. F.↗

Design of printed circuit coils

Spiral-like coil is printed with several extra turns which increase the realizable coil inductance. Included are shorting connections which not only short the extra turns, but also short out several turns of the main body. Coil tuning is accomplished by removing the shorts until the desired inductance is obtained.

Higgins, W. T.↗

The French short term radiopropagation predictions in the decameter band

Weekly and daily predictions of the ionospheric characteristics relevant to radio propagation are considered. A description of the techniques involved is given as well as examples showing how the prediction messages are prepared. The short term predictions are confined to restricted geographical areas and are relevant to radio circuits whose terminators are both located inside the same zone. They can be used with a reasonable approximation for circuits less than 3000 km of length whose reflection point lies within a given zone.

Lassudrie-Duchesne, P.↗

Cycle life test and failure model of nickel-hydrogen cells

Six ampere hour individual pressure vessel nickel hydrogen cells were charge/discharge cycled to failure. Failure as used here is defined to occur when the end of discharge voltage degraded to 0.9 volts. They were cycled under a low earth orbit cycle regime to a deep depth of discharge (80 percent of rated ampere hour capacity). Both cell designs were fabricated by the same manufacturer and represent current state of the art. A failure model was advanced which suggests both cell designs have inadequate volume tolerance characteristics. The limited existing data base at a deep depth of discharge (DOD) was expanded. Two cells of each design were cycled. One COMSAT cell failed at cycle 1712 and the other failed at cycle 1875. For the Air Force/Hughes cells, one cell failed at cycle 2250 and the other failed at cycle 2638. All cells, of both designs, failed due to low end of discharge voltage (0.9 volts). No cell failed due to electrical shorts. After cell failure, three different reconditioning tests (deep discharge, physical reorientation, and open circuit voltage stand) were conducted on all cells of each design. A fourth reconditioning test (electrolyte addition) was conducted on one cell of each design. In addition post cycle cell teardown and failure analysis were performed on the one cell of each design which did not have electrolyte added after failure.

Smithrick, J. J.↗

Cycle life test and failure model of nickel-hydrogen cells

Six ampere hour individual pressure vessel nickel hydrogen cells were charge/discharge cycled to failure. Failure as used here is defined to occur when the end of discharge voltage degraded to 0.9 volts. They were cycled under a low earth orbit cycle regime to a deep depth of discharge (80 percent of rated ampere hour capacity). Both cell designs were fabricated by the same manufacturer and represent current state of the art. A failure model was advanced which suggests both cell designs have inadequate volume tolerance characteristics. The limited existing data base at a deep depth of discharge (DOD) was expanded. Two cells of each design were cycled. One COMSAT cell failed at cycle 1712 and the other failed at cycle 1875. For the Air Force/Hughes cells, one cell failed at cycle 2250 and the other failed at cycle 2638. All cells, of both designs, failed due to low end of discharge voltage (0.9 volts). No cell failed due to electrical shorts. After cell failure, three different reconditioning tests (deep discharge, physical reorientation, and open circuit voltage stand) were conducted on all cells of each design. A fourth reconditioning test (electrolyte addition) was conducted on one cell of each design. In addition post cycle cell teardown and failure analysis were performed on the one cell of each design which did not have electrolyte added after failure. Previously announced in STAR as N83-25038

Smithrick, J. J.↗