Creating a Simulation Platform for Research and Development of Advanced Control Methods

Advanced nuclear reactors are essential to meet the changing energy requirements throughout both the United States and the rest of world. In addition to other features, they are designed to enable deployment in remote locations and operate in a fully (or near-fully) autonomous manner, which will require a new control paradigm. To realize autonomously operating reactors, the U.S. Department of Energy’s Nuclear Energy Enabling Technologies Advanced Sensors and Instrumentation (NEET ASI) program conducts research and development into the enabling technologies and methods needed, including digital twins, machine learning, and risk modeling, in addition to various types of control methods. These technologies and methods are the key foundations needed to achieve fully autonomous systems. To develop and evaluate the technologies and methods necessary for achieving autonomous operations, it is critical to identify a software tool capable of integrating all the required elements. In surveying the available solutions, no software platforms were identified that could accomplish what was needed without introducing drawbacks. This challenge was the motivation for the current effort: to develop a software platform that can seamlessly integrate autonomouscontrol-enabling technologies and methods, allowing for accelerated research and development and transfer of ideas. The resulting platform, known as the Control and Optimization Modular Modeling Application for Nuclear Deployment (COMMAND), is Python-based, and leverages open-source tools to provide flexibility and facilitate building upon prior research. It is designed to enable advanced reactor developers to deploy and test advanced control technologies and methods coupled with their own models, solutions, and hardware. Given the substantial undertaking of developing such a platform, the current effort focused on laying down scalable, flexible software foundations and infrastructure, then demonstrating the platform via a use case. These foundations included developing generic modules, which contain the base variable and system blocks (the information and functional building blocks, respectively, that can be used to design a simulation) and the data handling and storage blocks needed to exchange information between the various blocks; as well as enablingtechnology-specific modules. This platform was evaluated via a use case, which was to simulate and control a process for the Microreactor Automated Control System (MACS) test bed. While MACS is not currently directly coupled to any specific microreactor physics, it was initially developed in concert with the Microreactor Applications Research Validation and Evaluation (MARVEL) microreactor, and so the MARVEL physics are used here. As part of this use case, several enabling-technology-specific blocks within COMMAND were integrated, including a proportional integral derivative (PID) control block, a Reactor Excursion and Leak Analysis Program (RELAP5-3D) block, and an anomaly detection block. The COMMAND software platform was successfully demonstrated to achieve the scalability and flexibility objectives of this effort and will be leveraged by the program’s research efforts to advance state of the art control methodologies towards autonomous operations of advanced reactors. As new use cases are created and implemented, it is anticipated that COMMAND will continue to grow and evolve to meet new requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative Assessment of Experimental Testing of Instrument with an Embedded Digital Device Using Model-Based and Conventional Methods

The use of digital equipment has not been widespread in U.S. nuclear facilities. A major contributing factor to this situation arises from regulatory concerns about common cause failures (CCFs) stemming from the use of identical software in redundant systems, questions as to how to quantify the reliability of software-based products, validity of tools that are used for software verification and validation (V&V), and the effectiveness of software QA procedures. Compounding the concerns are sporadic incidents of digital equipment malfunctions in nuclear power plants, including lockups resulting from software memory leaks, feedwater control malfunctions due to excessive traffic on Ethernet networks, software logic errors, and other problems leading to plant trips. Additionally, the limited amount of demonstrated research and a lack of industry consensus on quantitative software reliability methodologies has hindered the widespread adoption of digital I&C in the nuclear industry. In a recent Regulatory Issue Summary (RIS), the U.S. Nuclear Regulatory Commission (NRC) identified concerns about the impact of greater use of instrumentation and control (I&C) equipment with an embedded digital device (EDD) [1]. Specifically, the NRC staff states that increased use of such devices “may increase a facility’s vulnerability to a CCF” (i.e., common-cause failure). The prevailing NRC guidance regarding software CCF (SCCF) identifies two design attributes that are acceptable for eliminating CCF concerns: (1) diversity or (2) testability (specifically, 100% testability). Either solution can result in high costs and remaining licensing uncertainty (i.e., how much diversity is enough? how to ensure test coverage of every possible sequence of device states?). Consequently, many utilities and reactor designers have limited or avoided more extensive use of digital technology to minimize licensing, scheduling, and financial risk. Without development of cost effective qualification methods to satisfy regulatory requirements and address the potential for CCF vulnerability associated with EDDs, the nuclear power industry may not be able to realize the benefits of digital technology achieved by other industries. In order to address these challenges, the U.S. Department of Energy (DOE) is sponsoring this research to assess the prospect of CCF in digital I&C equipment. The purpose of the current research is to develop an effective approach employing science-based methods to resolve concerns about CCF vulnerability that serve to inhibit deployment of advanced instrumentation (e.g., sensors, actuators, microcontrollers) with EDDs in nuclear power applications. The research objectives address the challenge of establishing high levels of safety and reliability assurance needed for the qualification of EDDs (e.g., microprocessors, programmable logic devices) that are subject to software design faults, complex failure modes, and CCF vulnerability. Specific objectives are: (1) assess the regulatory context for treatment of CCF vulnerability a graded approach to their qualification, (3) develop and extend model-based testing methods to enable effective demonstration of whether devices are subject to CCF, which may arise from vulnerabilities introduced at any stage of the design lifecycle, (4) establish a cost-effective testing framework that incorporates automation and test scenario prioritization, and (5) demonstrate the qualification approach through selection and testing of candidate digital device(s). This report documents an assessment of the results from experimental testing of a representative instrument with an embedded digital device. The experiment serves as a proof-of-concept demonstration of a model-based testing (MBT) framework. The objective of MBT is to ensure that an EDD undergoes suitably comprehensive testing to establish that it is not subject to SCCF. The approach by which MBT accomplishes this objective is through development and application of an effective test suite that provides the appropriate coverage to detect the full range of postulated faults that may arise at the requirements, design, and code (implementation) level of the EDD software. The findings of the experiment involve the application of the MBT framework by Ohio State University (OSU) through testing of the selected demonstration instrument (i.e., the prototype smart pressure sensor developed by Virginia Commonwealth University, VCU). In addition, the experiment findings also involve application of a more conventional black-box testing approach that serves as a baseline against which the MBT methodology can be compared. The primary outcome documented in this report is the comparative analysis of the capabilities demonstrated for each method. The results of the analysis demonstrate clear benefits that arise from the MBT methodology. The comparison indicates greater effectiveness from the more comprehensive evidence available through MBT and enhanced efficiency achieved through automation within the MBT framework. The structure of the report addresses the approach and application of each test method as well as the comparative analysis of the experimental results. Chapter 2 gives a summary overview of the demonstration approach. Chapter 3 covers the baseline testing and Chapter 4 documents the model-based testing. Chapter 5 describes the findings of the comparative analysis and presents the conclusions that can be drawn about the effectiveness and efficiency of the MBT methodology.

47 OTHER INSTRUMENTATION↗

Energy Storage and Generation for Extreme Temperature and Pressure and Directional Measurement While Drilling Applications

FastCAP Systems Corporation has successfully completed all milestones defined by the award DE-EE0005503. Under this program, FastCAP developed three critical subassemblies to TRL3 demonstrating proof of concept of a geothermal MWD power source. This power source includes an energy harvester, electronics and a novel high temperature ultracapacitor (“ultracap”) rechargeable energy storage device suitable for geothermal exploration applications. FastCAP’s ruggedized ultracapacitor (ultracap) technology has been proven and commercialized in oil and gas exploration operating to rated temperatures of 150°C. Characteristics of this technology are that it is rechargeable and relatively high power. This technology was the basis for the advancements in rechargeable energy storage under this project. The ultracap performs reliably at 250°C and beyond and operates over a wide operating temperature range: -5°C to 250°C. The ultracap has significantly higher power density than lithium thionyl chloride batteries, a non-rechargeable incumbent used in oil and gas drilling today. Several hermetically sealed, prototype devices were tested in our laboratories at constant temperatures of 250°C showing no significant degradation over 2000 hours of operation. Other prototypes were tested at Sandia National Lab in the month of April, 2015 for a third party performance validation. These devices showed outstanding performance over 1000 hours of operation at three rated temperatures, 200°C, 225°C and 250°C, with negligible capacitance degradation and minimal equivalent series resistance (ESR) increase. Similarly, FastCAP’s ruggedized electronics have been proven and commercialized in oil and gas exploration operating to rated temperatures of 150°C. This technology was the basis for the advancements in downhole electronics under this project. Principal contributions here focused on design for manufacture innovations that have reduced the prototype build cycle time by a factor of 10x. The electronics have demonstrated a substantially reduced design cycle time by way of process and material selection innovations and have been qualified for 250°C / 10 Grms for at least 200 hours. FastCAP has also invented a rotary inertial energy generator (RIEG) to harvest various mechanical energy sources that exist downhole. This device is flow-independent and has been demonstrated as a proof of concept to survive geothermal well temperatures under this project. The herein energy harvester has been developed to provide operational power by harvesting rotational mechanical energy that exists downhole in geothermal drilling. The energy harvester has been tested at 250°C / 10 Grms for 200 hours. Deployment of these technologies in geothermal drilling and exploration applications could have an immediate and significant impact on the effectiveness and efficiency of drilling processes, particularly with regard to use of advanced logging and monitoring techniques. The ultimate goal of this work is to reduce drilling risk to make geothermal energy more attractive and viable to the customer. Generally speaking, we aim to support the transfer of MWD techniques from oil and gas to geothermal exploration with considerations toward the practical differences between the two. One of the most significant obstacles to the deployment of advanced drilling and production techniques in the geothermal context are limitations related to the maximum operating temperatures of downhole batteries used to provide power for downhole sensors, steering tools, telemetry equipment and other MWD/LWD technologies. FastCAP’s higher temperature ultracapacitor technology will provide power solutions for similar advanced drilling and production techniques, even in the harsher environments associated with geothermal energy production. This ultracapacitor will enable downhole power solutions for the geothermal industry capable of the same reliable and safe operation our team has demonstrated in the oil and gas context. Without batteries, geothermal MWD is left without a downhole power source. Some very high temperature turbines exist but provide unsteady, intermittent power and no power when the flow is off. In high loss formations common to geothermal exploration, it will be auspicious to support air drilling in which case there is no flow to power a turbine at all. In the best case, rechargeable energy storage will help to buffer unsteady power from non-battery power sources and in the worst case it will be needed to store energy from highly intermittent sources to provide a continuously operable power source to the tool.

15 GEOTHERMAL ENERGY↗

Renewable Surface Fluorescence Sandwich Immunoassay Biosensor for Rapid Sensitive Botulinum Toxin Detection in an Automated Fluidic Format

A renewable surface biosensor for rapid detection of botulinum toxin is described based on fluidic automation of a fluorescence sandwich immunoassay, using a recombinant fragment of the toxin heavy chain as a structurally valid simulant. Monoclonal antibodies AR4 and RAZ1 bind to separate epitopes of both this fragment and the holotoxin. The AR4 antibody was covalently bound to Sepharose beads and used as the capture antibody. A rotating rod flow cell was used to capture these beads delivered as a suspension by the sequential injection flow system, creating a 3.6 microliter column. After perfusing the bead column with sample and washing away the matrix, the column was perfused with Alexa 647 dye-labeled RAZ1 antibody as the reporter. Optical fibers coupled to the rotating rod flow cell at a 90 degree angle to one another delivered excitation light from a HeNe laser and collected fluorescent emission light for detection. After each measurement, the used sepharose beads are released and replaced with fresh beads. In a rapid screening approach to sample analysis, the toxin simulant was detected to concentrations of 10 pM in less than 20 minutes.

59 BASIC BIOLOGICAL SCIENCES↗

Response Time Analysis and Test of Protection System Instrument Channels for APR1400 and OPR1000

Safety limits are required to maintain the integrity of physical barriers designed to prevent the uncontrolled release of radioactive materials in nuclear power plants. The safety analysis establishes two critical constraints that include an analytical limit in terms of a measured or calculated variable, and a specific time after the analytical limit is reached to begin protective action. Keeping with the nuclear regulations and industry standards, satisfying these two requirements will ensure that the safety limit will not be exceeded during the design basis event, either an anticipated operational occurrence or a postulated accident. Various studies on the setpoint determination methodology for the safety-related instrumentation have been actively performed to ensure that the requirement of the analytical limit is satisfied. In particular, the protection setpoint methodology for the advanced power reactor 1400 (APP1400) and the optimized power reactor 1000 (OPR1000) has been recently developed to cover both the design basis event and the beyond design basis event. The developed setpoint methodology has also been quantitatively validated using specific computer programs and setpoint calculations. However, the safety of nuclear power plants cannot be fully guaranteed by satisfying the requirement of the analytical limit. In spite of the response time verification requirements of nuclear regulations and industry standards, it is hard to find the studies on the systematically integrated methodology regarding the response time evaluation. In cases of APR1400 and OPR1000, the response time analysis for the plant protection system is partially included in the setpoint calculation and the response time test is separately performed via the specific plant procedure. The test technique has a drawback which is the difficulty to demonstrate completeness of timing test. The analysis technique has also a demerit of resulting in extreme times that not actually possible. Thus, the establishment of the systematic response time evaluation methodology is needed to justify the conformance to the response time requirement used in the safety analysis. This paper proposes the response time evaluation methodology for APR1400 and OPR1000 using the combined analysis and test technique to confirm that the plant protection system can meet the analytical response time assumed in the safety analysis. In addition, the results of the quantitative evaluation performed for APR1400 and OPR1000 are presented in this paper. The proposed response time analysis technique consists of defining the response time requirement, determining the critical signal path for the trip parameter, allocating individual response time to each component on the signal path, and analyzing the total response time for the trip parameter, and demonstrates that the total analyzed response time does not exceed the response time requirement. The proposed response time test technique is composed of defining the response time requirement, determining the critical signal path for the trip parameter, determining the test method for each component on the signal path, performing the response time test, and demonstrates that the total test result does not exceed the response time requirement. The total response time should be tested in a single test that covers from the sensor to the final actuation device on the instrument channel. When the total channel is not tested in a single test, separate tests on groups of components or single components including the total instrument channel shall be combined to verify the total channel response. For APR1400 and OPR1000, the ramp test technique is used for the pressure and differential pressure transmitters and the step function testing technique is applied to the signal processing equipment and final actuation device. As a result, it can be demonstrated that the response time requirement is satisfied by the combined analysis and test technique. Therefore, the proposed methodology in this paper plays a crucial role in guaranteeing the safety of the nuclear power plants systematically satisfying one of two critical requirements from the safety analysis. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

EPIC Calibration/Validation Experiment Field Campaign Report

A field exercise involving several different kinds of Unmanned Aerial Systems (UAS) and supporting instrumentation systems provided by DOE/ARM and NOAA/NSSL was conducted at the ARM SGP site in Lamont, Oklahoma on 29-30 October 2016. This campaign was part of a larger National Oceanic and Atmospheric Administration (NOAA) UAS Program Office program awarded to the National Severe Storms Laboratory (NSSL). named Environmental Profiling and Initiation of Convection (EPIC). The EPIC Field Campaign (Test and Calibration/Validation) proposed to ARM was a test or “dry-run” for a follow-up campaign to be requested for spring/summer 2017. The EPIC project addresses NOAA’s objective to “evaluate options for UAS profiling of the lower atmosphere with applications for severe weather.” The project goal is to demonstrate that fixed-wing and rotary-wing small UAS have the combined potential to provide a unique observing system capable of providing detailed profiles of temperature, moisture, and winds within the atmospheric boundary layer (ABL) to help determine the potential for severe weather development. Specific project objectives are: 1) to develop small UAS capable of acquiring needed wind and thermodynamic profiles and transects of the ABL using one fixed-wing UAS operating in tandem with two different fixed rotary-wing UAS pairs; 2) adapt and test miniaturized, high-precision, and fast-response atmospheric sensors with high accuracy in strong winds characteristic of the pre-convective ABL in Oklahoma; 3) conduct targeted short-duration experiments at the ARM Southern Great Plains site in northern Oklahoma concurrently with a second site to be chosen in “real-time” from the Oklahoma Mesonet in coordination with the (National Weather Service (NWS)-Norman Forecast Office; and 4) gain valuable experience in pursuit of NOAA’s goals for determining the value of airborne, mobile observing systems for monitoring rapidly evolving high-impact severe weather conditions not observed with current operational systems. OU operated three UAS at the Lamont SGP site – the OU CopterSonde, the OU Iris, and the Meteomatics Meteodrone – under a blanket Federal Aviation Administration (FAA) Certificate of Authorization (COA) allowing flights up to 400 feet above ground level (AGL). The mission for the rotary-wing UAS involved four aircraft, three from the ARM Lamont site and one from an Oklahoma Mesonet site located at Medford, involving a vertical ascent to an altitude of 400 ft (130 m) AGL at ~ 30 minute intervals for ~ 5 hours duration on each of the two experiment days. This operation was conducted in close coordination with NSSL-launched rawinsonde balloons at the two sites, and operation of a fixed-wing UAS from the University of Colorado called the TTwistor that flew mission flight legs between the Lamont site and Medford. The NSSL operation at Medford (outside of ARM) also involved use of their Collaborative Lower Atmosphere Mobile Profiling System (CLAMPS) ground-based remote-sensing system for measuring atmospheric profiles of temperature, moisture, and winds with atmospheric emitted radiance interferometer (AERI), microwave radiometer, and Doppler wind lidar systems. The ARM Facility supported the project by providing access to their instrumented tower data at Lamont (at three levels), as well as AERI and Doppler wind lidar data obtained from systems quite similar to those used by CLAMPS. These non-UAS data from both ARM and NSSL provided the observations used to validate the experimental UAS observations.

atmospheric boundary layer↗

In Situ Atmospheric Plume Thermometry via Carbon Monoxide Spectral Profile: Laboratory and Field Validation

For small molecules with large rotational constants, knowing the relative intensities of the ro-vibrational transitions can be used to determine the temperature within a gas plume. We demonstrate the use of carbon monoxide (CO) as an in situ spectroscopic probe of gas plume temperature by application of both laboratory and standoff Fourier transform infrared spectroscopy to monitor the CO spectral response at different temperatures. Here, the measured CO rotational contours were analyzed using a simple Boltzmann model to deduce the population distribution of the J-levels, from which the in-plume temperature is deduced. The method was vetted by comparing deduced temperatures in both static laboratory measurements of known temperatures, as well as field measurements using a simulated smokestack release. For the smokestack experiments, spectroscopically deduced temperatures were compared to readings from a series of thermocouples placed at strategically sampled distances along the plume trajectory. Both the spectroscopically-derived and thermocouple-measured temperatures revealed an expansion-induced (mixing) rapid cooling of the plume, with the infrared thermometry values displaying greater temperature values which are believed to better represent the actual plume temperatures.

Analysis of rotational structure↗

Spreader-Bar Radiation Detection System Enhancements: A Modeling and Simulation Study

An investigation of radiation detectors on crane-mounted platforms was performed to understand the limitations and optimal capability of these types of systems. Crane-mounted systems are primarily focused on crane-mounted radiation detector systems, where the detectors are mounted on a spreader-bar platform. Spreader bars are attached with cables to a crane at seaports to load and unload containers from cargo ships. The bars can spread from 20 feet to 53 feet using hydraulics, allowing a single bar to move a variety of container lengths. Spreader-bars are also used on straddle carriers, which move containers around the laydown yard in the port. Spreader bar radiation detection (SBRD) systems are commercially available from at least two companies. These systems employ a set of spectroscopic sensors placed on the underside of a gantry crane and held near the top of a cargo container for detection. These systems have been previously tested and some issues and limitations observed. Radiation detectors mounted on spreader-bars are single sided systems (observing cargo only from the top) and it is therefore challenging to obtain the same sensitivity as double-sided systems (for example, portal monitors) especially when considering the possible amounts of intervening cargo that could be present. The approximately exponential attenuation of gamma rays in intervening dense cargo presents an inherent limitation to detection. However, SBRD systems hold detectors closer to the container, have a longer dwell time, and may have lower background (over the ship); all of these aspects help mitigate the single-sided issue. In addition, there are operational considerations that make spreader-bar radiation systems attractive. These include scanning for radiation during other operations (loading, unloading or container movement) which minimizes additional time for scanning, incorporating the radiation detection into existing equipment to minimize initial cost, and in the case of ship unloading, scanning the containers before reaching the laydown yard. This study is focused on researching optimized configurations of SBRD systems, including number of detectors, locations, and best use of detector data, to determine a reasonable limit on the capability of these types of systems. The results will help support decisions on where and how these systems might be effectively deployed, and could be used for future specification development for SBRD acquisition. The next phase of this research and investigation into SBRD systems and quantification of the possible improved capability with an enhanced SBRD is the focus of this report. Supporting this investigation, detailed models of an enhanced SBRD system were created using a 3D radiation transport code, and models were run to simulate the data from sources and background for a realistic cargo-loading port environment. The enhanced SBRD had increased detector material (numbers of detectors) compared to the commercial systems, with a distribution providing more uniform coverage. Measurements using small industrial sources were made with an enhanced SBRD system developed by Sandia National Laboratory to support model validation to establish credibility for the simulations of these threat and background scenarios. A significant simulation effort was undertaken to simulate sources of interest within a 40-foot cargo container. In order to estimate the performance of a generalized SBRD system in scenarios including background and cargo, a highly enriched uranium (HEU) test source (with 3x10 -8 232 U by weight) within a wood cargo model was simulated for a 40-foot cargo container. This source was placed at a variety of locations, and the flux from the source was multiplied as necessary to create estimated minimal detectable quantities (MDQ) figures for various quantities of HEU. Simulated data sets were produced corresponding to a complete container offloading scenario for a large number of statistical realizations. Significant work was performed on both the algorithm development and the container cargo distributions entering the US, and the result of this modeling, validation, and simulation effort was a set of estimates of the performance of a variety of radiation detection algorithms in this cargo-screening environment. In the case of algorithms, a variety of contemporary radiation detection and identification approaches were employed, and the optimal approaches to selecting time and location subsets of detector data were explored. In all cases, algorithm performance was compared, and the best approaches were suggested along with the best expected performance from the enhanced SBRD. In general, template-matching schemes employing a limited set of regression parameters tend to provide best results. The improvements of an enhanced SBRD with increased detector material and improved algorithms result in an effective MDQ of 10 kg of HEU in ~50 percent of the imported cargo in 40-foot containers, assuming a random source location. This is approximately two times the capability of the estimated performance of the commercial systems. For an MDQ of the 10 kg HEU source located in the worst location (bottom of the 40-foot container), the volume of cargo scanned drops to 10% for the enhanced SBRD, again a factor of two or more larger than the commercial systems. Enhancing the SBRD systems by adding more detectors, providing a more uniform coverage, and incorporating more advanced algorithms will result in a significant increase in capability. Although this investigation provided some indication of the performance capabilities of an enhanced SBRD system, additional work is needed to estimate the capability for other container configurations, such as the 20 and 45 foot containers. Since the 20-foot container weight limit is similar to the 40-foot, more dense cargo is typically shipped in 20-foot containers. This will result in a smaller percentage of cargo scanned for the 20-foot containers (for a particular source quantity) compared to the 40-foot containers. In addition to other configuration, other source material needs to be investigated to understand the capabilities for the entire threat space, where only HEU is considered in this work.

crane-mounted↗

The EGS Collab Project: Status and Accomplishments

The EGS Collab project, supported by the US Department of Energy, is addressing challenges in implementing enhanced geothermal systems (EGS). This includes improving understanding of the stimulation of crystalline rock to create appropriate flow pathways, and the ability to effectively simulate both the stimulation and the flow and transport processes in the resulting fracture network. The project is performing intensively monitored rock stimulation and flow tests at the 10-m scale in an underground research laboratory. Data and observations from the field test are compared to simulations to understand processes and to build confidence in numerical modeling of the processes. In Experiment 1, we examined hydraulic fracturing an underground test bed at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, at a depth of approximately 1.5 km. We drilled eight sub-horizontal boreholes in a well-characterized phyllite. Six of the boreholes were instrumented with many sensor types to allow careful monitoring of stimulation events and flow tests, and the other two boreholes were used for water injection and production. We performed a number of stimulations and flow tests in the testbed. Our monitoring systems allowed detailed observations and collection of numerous data sets of processes occurring during stimulation and during dynamic flow tests. Long-term ambient temperature and chilled water flow tests were performed in addition to many tracer tests to examine system behavior. Data were rapidly analyzed, allowing adaptive control of the tests. Numerical simulation was used to answer key experimental design questions, to forecast fracture propagation trajectories and extents, and to analyze and evaluate results. Many simulations were performed in near-real-time in conjunction with the field experiments, with more detailed process study simulations performed on a longer timeframe. Experiment 2 will examine hydraulic shearing in a test bed being built at the SURF at a depth of about 1.25 km in amphibolite under a different set of stress and fracture conditions than Experiment 1. Five sets of fracture orientations were considered in design, and three orientations seem to be consistently observed.

EGS Collab↗

Visualization and Quantification of Wind Induced Variability in Hydrogen Clouds Following Releases of Liquid Hydrogen: Preprint

Well characterized experimental data for consequence model validation is important in progressing the use of liquid hydrogen as an energy carrier. In 2019, the Health and Safety Executive (HSE) undertook a series of liquid hydrogen dispersion and combustion experiments as a part of the Pre-normative Research into the Safe Use of Liquid Hydrogen (PRESLHY) project. In partnership between the National Renewable Energy Laboratory (NREL) and HSE, time and spatially varying hydrogen concentration measurements were made in 25 dispersion experiments and 23 congested ignition experiments associated with PRESLHY WP3 and WP5, respectively. These measurements were undertaken using the hydrogen wide area monitoring system developed by NREL. During the 23 congested ignition experiments, high variability was observed in the measured explosion severity during experiments with similar initial conditions. This led to the conclusion that wind, including localized gusts, had a large influence on the dispersion of the hydrogen, and therefore the quantity of hydrogen that was present in the congested region of the explosions. Using the hydrogen concentration measurements taken immediately prior to ignition, the hydrogen clouds were visualized in an attempt to rationalize the variability in overpressure between the tests. Gaussian process regression was applied to quantify the variability of the measured hydrogen concentrations. This analysis could also be used to guide modifications in experimental designs for future research on hydrogen combustion behavior.

HSR&D↗

The Timepix4 analog front-end design: Lessons learnt on fundamental limits to noise and time resolution in highly segmented hybrid pixel detectors

This manuscript describes the optimization of the front-end readout electronics for high granularity hybrid pixel detectors. The theoretical study aims at minimizing the noise and jitter. The model presented here is validated with both circuit post layout simulations and measurements on the Timepix4 Application Specific Integrated Circuit (ASIC). The analog front-end circuit and the procedure to optimize the dimensions of the main transistors are described with detail. The Timepix4 is the most recent ASIC designed in the framework of the Medipix4 Collaboration. It was manufactured in 65nm CMOS process, and consists of a four side buttable matrix of 448 × 512 pixels with 55µm pitch. The analog front-end has a gain of ~36mV/ke - when configured in High Gain Mode, and ~20mV/ke - when configured in Low Gain Mode. The Equivalent Noise Charge (ENC) is ~68e - rms and ~80e - rms in High Gain Mode and in Low Gain Mode respectively. In event driven mode the incoming hits can be time stamped within a ~ 200ps time bin and the chip can deal with a maximum flux of ~ 3.6MHzmm –2 s –1 . In photon counting mode, the chip can deal with up to ~ 5GHzmm –2 s –1 . The routine designed to optimize the Timepix4 front-end is then used to analyze the performance limits in terms of jitter and noise for Charge Sensitive Amplifiers in pixel detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lithium-Ion Battery Diagnostics Using Electrochemical Impedance via Machine-Learning

Diagnosing battery states such as health, state-of-charge, or temperature is crucial for ensuring the safety and reliability of electrochemical energy storage systems. While some states, such as temperature, may be measured using cheap sensors, accurate diagnosis of battery health metrics usually requires time-consuming performance measurements, making them infeasible for use in real-world operation. These health metrics can be measured during lab-testing and then estimated on-line using predictive life models or via state observer algorithms such as Kalman filters, but these predictive methods should be supplemented by actual measurement of battery health whenever possible to ensure reliability. Rapid measurement of battery health may be done by various types of fast diagnostic techniques such as electrochemical impedance spectroscopy (EIS), which can be performed in only a few minutes and require only a fraction of the energy and power needed for a full charge and discharge measurement. But there is a substantial challenge for estimating battery health using EIS data, as EIS is sensitive to cell temperature, state-of-charge, current, and resting time in addition to health. Thus, utilizing EIS data to predict battery capacity requires correcting for all these additional variables, a task that is extremely difficult to handle analytically. This talk utilizes machine-learning methods to estimate the effectiveness of battery capacity prediction from EIS data, leveraging a data set of hundreds of EIS measurements recorded at varying temperature and state-of-charge throughout a 500-day aging study of 32 commercial, large-format NMC-Graphite lithium-ion batteries. Using EIS as input to machine-learning models is complicated by the nonlinear response of impedance to battery health, temperature, and state-of-charge, as well as the collinearity between the impedance response at neighboring frequencies, which can easily lead to overfit models. To train robust models, features from EIS data need to be extracted from the data or some subset of critical frequencies selected. Many approaches for extracting and selecting features from EIS data from electrochemical analysis and machine-learning fields were identified for analysis: using the entire raw spectra; selection of one, two, or many frequencies from the entire spectra; selecting interesting points from the EIS measurement using domain knowledge; fitting EIS with an equivalent-circuit model; calculating statistics on the raw impedance values; and reducing the dimensionality of the data using unsupervised linear (principal component analysis) and non-linear (uniform manifold approximation and projection) methods. These approaches were rigorously compared using a machine-learning pipeline approach, training linear, Gaussian process, and random forest regression models and quantifying performance using cross-validation as well as a held-out test set. An artificial neural network model trained on the raw spectra was also tested. Promising pipelines were fine-tuned via Bayesian hyperparameter optimization using cross-validation loss and training with class-specific weights to counter data set imbalance. The most reliable method for utilizing impedance in this work was the selection of two optimal frequencies through an exhaustive search, resulting in about 2% mean absolute error on test data for both Gaussian process and random forest model architectures. Interrogation of a variety of models reveals critical frequencies of 100 Hz and 103 Hz for this data set, though the optimal set of frequencies is not necessarily intuitive, i.e., the best performing models are not simply those that use impedance at frequencies that have the highest correlation to the relative discharge capacity. The best performing model is an ensemble model, which is able to predict battery capacity with 1.9% mean absolute error for unseen cells using impedance recorded at a variety of temperatures and states-of-charge.

battery↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Acoustic-based monitoring and machine learning of component status for microreactor applications

This report provides a description and assessment of recent efforts to couple acoustic-based experimental measurements and characterization with machine learning models in order to enhance structural health monitoring capabilities for nuclear microreactors. With resilient embedded sensors in development by others supported by programs funded by the US Department of Energy’s Office of Nuclear Energy, the work described herein builds upon ongoing efforts to improve non-destructive testing technology that relates measured acoustic signatures to component stresses and/or structural defects, using a combination of new experimental measurements and machine learning architectures. The experimental procedure remained similar to that developed for the previous year’s demonstration of damage detection by the authors, with the same damaged sample tested under similar applied stress conditions. Notably, a new mounting fixture was designed and implemented to improve measurement consistency and a more sophisticated laser Doppler vibrometer was employed to make high-fidelity vibration measurements. Two nominally identical sets of training data were collected for each experimental setup to better understand the repeatability of the experiment and to better test the generality of trained neural network models. Additionally, we obtained new high-quality 3D mode shapes of the damaged test article at various stress and excitation levels, providing greater insights into the physical response of the sample during testing. Previously, we demonstrated that a machine learning model based on a convolutional neural network can predict structural details of an artificially introduced interface (intact, rough cut, smooth cut), and the applied torque level. In this study, we have transitioned to graph-based neural network architectures to better develop and test a flexible framework that is more suitable to being transferred away from controlled benchtop experiments and into more applied settings where less-structured data inputs may be expected. In general, performance testing of a graph neural network on frequency-domain representations of the data indicates strong and consistent identification of test conditions for datasets recorded on damaged components. With goals of predicting damage location and other changing experimental conditions using limited datasets, predictive models using a graph neural network architecture correctly predicted the applied torque level with an accuracy of 85% using only a single measurement point and predicted within one torque level in 95% of test windows. Predictions of damage location had limited success due to the symmetry and minimal number of the damage scenarios presented during model training. Results were ambiguous as to whether the model could detect the location of the artificial damage, or if it was instead learning the location of a given measurement point on the part and subsequently detecting which points were closest to the location of the damage. This finding will be factored into upcoming planned work on damaged graphite components, where new experimental tests with a larger number and variety of damage scenarios are expected to provide improved validation of recent developments in monitoring methodology.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High concentrations of ice: Investigations using polarimetric radar observations combined with in situ measurements and cloud modeling (Final Report)

This DOE-funded joint project had the over-arching goal of understanding the reasons for observed size distributions of ice particles in cold clouds. Its approach involves the use of cloud models and field observations by radar and aircraft of real storms. The project addresses three major research objectives: (1) Utilize a novel polarimetric radar technique to retrieve size distributions and amounts of ice from radar data collected during the previous DOE ARM field campaigns; (2) Evaluate the results of ice microphysical retrievals using available in situ aircraft measurements and other remote sensors (e.g., vertically pointing cloud radars and wind profilers); (3) Improve the treatment of microphysical processes leading to cloud glaciation and ice multiplication in numerical cloud models. The study was performed by three research organizations: University of Oklahoma, The Hebrew University of Jerusalem, Israel, and Lund University, Sweden. The Israel and Swedish partners were funded by the sub-awards from the University of Oklahoma. Cloud modeling studies have been performed by the research teams at The Hebrew University of Jerusalem (HUJ) and Lund University to identify the origins of high concentrations of cloud ice in areas of high ice water content (HIWC). The Hebrew University Cloud Model (HUCM) with full spectral bin microphysics and the Lund University aerosol-cloud (AC) model with a hybrid bin / bulk microphysics scheme complementing HUCM were utilized for simulations. Both research teams had particular focus on secondary ice production (SIP) as one of the possible sources of enhanced ice concentration. The HUJ group suggested a novel concept of ice multiplication during droplet freezing. It is assumed that splintering and droplet fragmentation during droplet freezing takes place because of dendritic growth within a supercooled drop. The resulting simulations of SIP generated small ice in concentrations exceeding hundreds per liter similar to what was observed in the HIWC regions of the tropical storms. The Lund team explored the SIP mechanisms such as breakup of ice particles due to ice-ice collisions and ice sublimation that are expected to dominate the continental storms. They also quantified the impact of homogeneous nucleation of cloud droplets on the total number concentration of ice at very low temperatures near the tops of the clouds. Additionally, the Lund AC model is able to simulate the effect of aerosols of various types (including biological) on the cloud life cycle and the corresponding ice production. The HUCM / AC model was used to simulate one of the “golden” cases of the DOE MC3E campaign on 20 May 2011. The model output was converted into the fields of polarimetric radar variables using the polarimetric radar forward operator developed at the University of Oklahoma and compared with radar observations and in situ microphysical measurements onboard research aircraft. It was demonstrated that specific differential phase KDP is the best radar parameter to identify the HIWC areas and quantify the corresponding ice parameters. For the first time, the shape of the vertical profile of KDP was realistically reproduced by the cloud model with the KDP maximum in the dendritic growth layer (DGL) centered at the -15°C isotherm. The University of Oklahoma team has developed a methodology for polarimetric radar retrievals of such microphysical parameters of ice as ice water content (IWC), mean volume diameter (Dm), and total number concentration (Nt) of ice particles. These retrievals have been validated using in situ aircraft measurements during 6 field campaigns and proved to be quite robust and reliable. This allowed to build the first climatology of the vertical profiles of polarimetric radar variables and retrieved microphysical parameters for the three types of weather systems: continental MCSs, maritime MCSs, and tropical cyclones / hurricanes (Hu and Ryzhkov 2022). The data were collected by a multitude of the WSR-88D radars in 13 continental and 10 maritime MCSs and 11 landfalling hurricanes. The HIWC areas were identified within the examined storms and the corresponding “HIWC statistics” was compared with the “background” one without HIWC. An overarching conclusion of the study is that maritime tropical storms (MCSs and hurricanes) are characterized by smaller size ice in higher concentration compared to the continental MCSs. High ice water content in the HIWC areas is primarily caused by a strong jump in a number concentration of ice particles rather than the increase of their size compared to the “background” environment. This may point to the homogeneous nucleation of excessive amounts of supercooled droplets and / or secondary ice production as the possible origins of HIWC. Such a climatology provides a good observational reference for the modelers to evaluate the performance of their models. As an example, the in-depth analysis of the 20 May 2011 MC3E case shows that the advanced cloud models developed in the course of this study still tend to underestimate the number concentration of ice in the HIWC areas although they succeed in reproducing realistically looking vertical profiles of IWC and Nt. The results of the project research are summarized in 13 journal papers.

54 ENVIRONMENTAL SCIENCES↗

BICEP Array: 150 GHz Detector Module Development

The Background Imaging of Cosmic Extragalactic Polarization (BICEP)/Keck (BK) collaboration is currently leading the quest for the highest-sensitivity measurements of the polarized cosmic microwave background (CMB) anisotropies on a degree scale with a series of cryogenic telescopes, of which BICEP Array (BA) is the latest Stage-3 upgrade with a total of ~ 32,000 detectors. The instrument comprises 4 receivers spanning 30–270 GHz, with the low-frequency 30/40 GHz deployed to the South Pole Station in late 2019. The full complement of receivers is forecast to set the most stringent constraints on the tensor-to-scalar ratio r. Building on these advances, the overarching small-aperture telescope concept is already being used as the reference for further Stage-4 experiment design. This paper describes the development of the BICEP Array 150 GHz detector module and its fabrication requirements, with highlights on the high-density time division multiplexing (TDM) design of the cryogenic circuit boards. The low-impedance wiring required between the detectors and the frst stage of superconducting quantum interference device amplifers is crucial to maintaining a stable bias current on the detectors. Here, a novel multilayer FR4 Printed Circuit Board with superconducting traces, capable of reading out up to 648 detectors, is detailed along with its validation tests. An ultra-high-density TDM detector module concept we developed for a CMB-S4-like experiment that allows up to 1920 detectors to be read out is also presented. TDM has been chosen as the detector readout technology for the Cosmic Microwave Background Stage-4 (CMB-S4) experiment based on its proven low-noise performance, predictable costs, and overall maturity of the architecture. The heritage for TDM is rooted in mm- and sub-mm-wave experiments dating back 20 years and has since evolved to support a multiplexing factor of 64x in Stage-3 experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Detecting fractures and monitoring hydraulic fracturing processes at the first EGS Collab testbed using borehole DAS ambient noise

Enhanced geothermal systems (EGS) require cost-effective monitoring of fracture networks. We validate the capability of using borehole distributed acoustic sensing (DAS) ambient noise for fracture monitoring using core photos and core logs. The EGS Collab project has conducted 10 m scale field experiments of hydraulic fracture stimulation using 50–60 m deep experimental wells at the Sanford Underground Research Facility (SURF) in Lead, South Dakota. The first EGS Collab testbed is located at 1616.67 m (4850 ft) depth at SURF and consists of one injection well, one production well, and six monitoring wells. All wells are drilled subhorizontally from an access tunnel called a drift. The project uses a single continuous fiber-optic cable installed sequentially in the six monitoring wells to record DAS data for monitoring hydraulic fracturing during stimulation. We analyze 60 s time records of the borehole DAS ambient noise data and compute the noise root-mean-square (rms) amplitude on each channel (points along the fiber cable) to obtain DAS ambient noise rms amplitude depth profiles along the monitoring wellbore. Our noise rms amplitude profiles indicate amplitude peaks at distinct depths. We compare the DAS noise rms amplitude profiles with borehole core photos and core logs and find that the DAS noise rms amplitude peaks correspond to the locations of fractures or lithologic changes indicated in the core photos or core logs. We then compute the hourly DAS noise rms amplitude profiles in two monitoring wells during three stimulation cycles in 72 h and find that the DAS noise rms amplitude profiles vary with time, indicating the fracture opening/growth or closing during the hydraulic stimulation. Our results demonstrate that borehole DAS passive ambient noise can be used to detect fractures and monitor fracturing processes in EGS reservoirs.

58 GEOSCIENCES↗