Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Scintillator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Characterization of Silicon-Photomultipliers for a Cosmic Muon Veto detector

A Cosmic Muon Veto (CMV) detector using extruded scintillators is being designed around the mini-Iron Calorimeter detector at the transit campus of the India-based Neutrino Observatory, Madurai for measuring its efficiency at shallow depth underground experiments. The scintillation signal is transmitted through a Wavelength Shifting (WLS) fibre and readout by Hamamatsu Silicon-Photomultipliers (SiPMs). A Light Emitting Diode (LED) system is included on the front-end readout for in-situ calibration of the gain of each SiPM. A characterization system was developed for the measurement of gain and choice of the overvoltage (V ov ) of SiPMs using the LED as well as a cosmic muon telescope. The V ov is obtained by studying the noise rate, the gain of the SiPM, and the muon detection efficiency. In case of any malfunction of the LED system during the operation, the SiPM can also be calibrated with the noise data as well as using radioactive sources. Furthermore, this paper describes the basic characteristics of the SiPM and the comparison of the calibration results using all three methods, as well as the V ov of the SiPMs and muon selection criteria for the veto detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a novel, windowless, amorphous selenium based photodetector for use in liquid noble detectors

Detection of the vacuum ultraviolet (VUV) scintillation light produced by liquid noble elements is a central challenge in order to fully exploit the available timing, topological, and calorimetric information in detectors leveraging these media. Here in this paper, we characterize a novel, windowless amorphous selenium based photodetector with direct sensitivity to VUV light. We present here the manufacturing and experimental setup used to operate this detector at low transport electric fields (2.7–5.2 V/μm) and across a wide range of temperatures (77 K–290 K). This work shows that the first proof-of-principle windowless amorphous selenium device is robust under cryogenic conditions, responsive to VUV light at cryogenic temperatures, and preserves argon purity. These findings motivate a continued exploration of amorphous selenium devices for simultaneous detection of scintillation light and ionization charge in noble element detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation results for a low energy nuclear recoil yields measurement in liquid xenon using the MiX detector

Measuring the scintillation and ionization yields of liquid xenon in response to ultra-low energy nuclear recoil events is necessary to increase the sensitivity of liquid xenon experiments to light dark matter. Neutron capture on xenon can be used to produce nuclear recoil events with energies below 0.3 keV NR via the asymmetric emission of γ rays during nuclear de-excitation. The feasibility of an ultra-low energy nuclear recoil measurement using neutron capture was investigated for the Michigan Xenon (MiX) detector, a small dual-phase xenon time projection chamber that is optimized for a high scintillation gain. Simulations of the MiX detector, a partial neutron moderator, and a pulsed neutron generator indicate that a population of neutron capture events can be isolated from neutron scattering events. Additionally, the rate of neutron captures in the MiX detector was optimized by varying the thickness of the partial neutron moderator, neutron pulse width, and neutron pulse frequency.

detector calibration↗

A portable and monoenergetic 24 keV neutron source based on 124Sb-9Be photoneutrons and an iron filter

A portable monoenergetic 24 keV neutron source based on the 124Sb-9Be photoneutron reaction and an iron filter has been constructed and characterized. The coincidence of the neutron energy from SbBe and the low interaction cross-section with iron (mean free path up to 29 cm) makes pure iron specially suited to shield against gamma rays from 124Sb decays while letting through the neutrons. To increase the 124Sb activity and thus the neutron flux, a >1 GBq 124Sb source was produced by irradiating a natural Sb metal pellet with a high flux of thermal neutrons in a nuclear reactor. The design of the source shielding structure makes for easy transportation and deployment. A hydrogen gas proportional counter is used to characterize the neutrons emitted by the source and a NaI detector is used for gamma background characterization. At the exit opening of the neutron beam, the characterization determined the neutron flux in the energy range 20–25 keV to be 6.00±0.30 neutrons per cm2 per second and the total gamma flux to be 245±8 gammas per cm2 per second (numbers scaled to 1 GBq activity of the 124Sb source). A liquid scintillator detector is demonstrated to be sensitive to neutrons with incident kinetic energies from 8 to 17 keV, so it can be paired with the source as a backing detector for neutron scattering calibration experiments. This photoneutron source provides a good tool for in-situ low energy nuclear recoil calibration for dark matter experiments and coherent elastic neutrino-nucleus scattering experiments.

Dark Matter detectors (WIMPs, axions, etc.)↗

Characterization of the Hamamatsu 8-inch R14688-100 PMT

Large-scale optical neutrino and dark-matter detectors rely on large-area photomultiplier tubes (PMTs) for cost-effective light detection. The new R14688-100 8-inch PMT developed by Hamamatsu provides state-of-the-art timing resolution of around 1 ns (FWHM), which can help improve vertex reconstruction and enable Cherenkov and scintillation light separation in scintillation-based detectors. This PMT also provides excellent charge resolution, allowing for precision photoelectron counting and improved energy reconstruction. The Eos experiment is the first large-scale optical detector to utilize these PMTs. Here, in this manuscript, we present a characterization of the R14688-100 single photoelectron response, such as the transit-time spreads, the dark-rates, and the afterpulsing. The single photoelectron response measurements are performed for the 206 PMTs that will be used in Eos.

47 OTHER INSTRUMENTATION↗

The ATLAS experiment at the CERN Large Hadron Collider: a description of the detector configuration for Run 3

The ATLAS detector is installed in its experimental cavern at Point 1 of the CERN Large Hadron Collider. During Run 2 of the LHC, a luminosity of ℒ = 2 × 10 34 cm -2 s -1 was routinely achieved at the start of fills, twice the design luminosity. For Run 3, accelerator improvements, notably luminosity levelling, allow sustained running at an instantaneous luminosity of ℒ = 2 × 10 34 cm -2 s -1 , with an average of up to 60 interactions per bunch crossing. The ATLAS detector has been upgraded to recover Run 1 single-lepton trigger thresholds while operating comfortably under Run 3 sustained pileup conditions. A fourth pixel layer 3.3 cm from the beam axis was added before Run 2 to improve vertex reconstruction and b-tagging performance. New Liquid Argon Calorimeter digital trigger electronics, with corresponding upgrades to the Trigger and Data Acquisition system, take advantage of a factor of 10 finer granularity to improve triggering on electrons, photons, taus, and hadronic signatures through increased pileup rejection. The inner muon endcap wheels were replaced by New Small Wheels with Micromegas and small-strip Thin Gap Chamber detectors, providing both precision tracking and Level-1 Muon trigger functionality. Trigger coverage of the inner barrel muon layer near one endcap region was augmented with modules integrating new thin-gap resistive plate chambers and smaller-diameter drift-tube chambers. Tile Calorimeter scintillation counters were added to improve electron energy resolution and background rejection. Upgrades to Minimum Bias Trigger Scintillators and Forward Detectors improve luminosity monitoring and enable total proton-proton cross section, diffractive physics, and heavy ion measurements. These upgrades are all compatible with operation in the much harsher environment anticipated after the High-Luminosity upgrade of the LHC and are the first steps towards preparing ATLAS for the High-Luminosity upgrade of the LHC. This paper describes the Run 3 configuration of the ATLAS detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Anode sensitivity calibration of photomultiplier tubes used as a readout of the ELOSS detector

We present and discuss the methodology and results for an anode sensitivity calibration of Photomultiplier Tubes (PMTs) that serve as the optical readout of the Energy Loss Optical Scintillation System (ELOSS). The ELOSS detector, under development at the Facility for Rare Isotope Beams (FRIB), is a gaseous Xe scintillation-based detector designed to identify the atomic number (Z) of nuclear reaction fragments by energy-loss measurement. Variation in the anode sensitivity from tube to tube of commercially available PMTs limits ELOSS from reaching its ultimate Z resolution. A methodical approach to calibrating PMT anode sensitivities to a single target value by systematic PMT gain corrections is presented. Although the calibration process is discussed in terms of its impact on ELOSS performance, the presented method is applicable to any optical detector system composed of a large number of PMTs needing anode sensitivity calibration.

Instrumentation for heavy-ion accelerators↗

Upgrade and characterization of the fast-channels of Imaging Neutral Particle Analyzers in the DIII-D tokamak

This publication presents the characterization of the recently upgraded fast (MHz) channels of the DIII-D Imaging Neutral Particle Analyzers. The new system allows for a phase space resolution of < 10 keV and < 10 cm. The main source of noise is due to the background radiation (neutrons and gammas) present in the diagnostic lab during experiments, which can hit the photomultipliers and generate large spikes in signal. Good linear correlations (r 2 > 0.9) are found between the average rate of noise spikes in the fast channels and the average neutron rate. Additional noise is caused by the scintillation of the optical fibers used to guide the signal to the acquisition system, which is induced by neutron and gamma impacts. A correlation factor r 2 > 0.6 between the baseline noise caused by this scintillation and the signals in the neutron diagnostic was found. Possible mitigation strategies, such as the use of shielding and filters, are discussed. These allow to reduce the noise spike rate by an order of magnitude and the noise baseline by a factor 4. Despite the noise, it is shown that the upgraded fast channels provide enough signal-to-noise ratio to observe coherent fluctuations of the energetic particle population.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calibration plan for the SBC 10-kg liquid argon detector with 100 eV target threshold

The Scintillating Bubble Chamber (SBC) Collaboration is designing a new generation of low background, noble liquid bubble chamber experiments with sub-keV nuclear recoil threshold. These experiments combine the electronic recoil blindness of a bubble chamber with the energy resolution of noble liquid scintillation, and maintain electron recoil discrimination at higher degrees of superheat (lower nuclear recoil thresholds) than Freon-based bubble chambers. A 10-kg liquid argon bubble chamber has the potential to set world leading limits on the dark matter nucleon cross-section for 𝒪(GeV/c 2 ) masses, and to perform a high statistics coherent elastic neutrino nuclear scattering measurement with reactor neutrinos. This work presents a detailed calibration plan to measure the detector response of these experiments, combining photoneutron scattering with two new techniques to induce sub-keV nuclear recoils: nuclear Thomson scattering and thermal neutron capture.

Dark Matter detectors (WIMPs, axions, etc.)↗

Reconstruction of neutrino events in the Accelerator Neutrino Neutron Interaction Experiment. Part I

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) was designed to reconstruct neutrino events from the Fermilab Booster Neutrino Beam (BNB) with the parallel goals of measuring neutron production in interactions with oxygen and serving as a testbed for new technology. The ANNIE detector consists of a 26-ton water Cherenkov target tank instrumented with conventional photomultiplier tubes (PMTs), a downstream tracking muon spectrometer, and an upstream double wall of plastic scintillator to serve to veto charged particles incoming from neutrino events that occur upstream of the experimental setup. ANNIE has also deployed multiple Large-Area Picosecond PhotoDetectors (LAPPDs) and a test vessel of water-based liquid scintillator (WbLS). This paper describes the event reconstruction performance of the detector before implementation of these novel technologies, which will serve as a baseline against which their impact can be measured. That said, even the techniques used for event reconstruction using only the conventional PMT array and muon spectrometer are significantly different than those used in other water Cherenkov detectors due to the small size of ANNIE (which makes nanosecond-scale timing not as useful as in a large detector) and the availability of reconstruction information from the tracking muon spectrometer. We demonstrate that combining the information from these two elements into a single fit using only pattern recognition yields a muon vertex uncertainty of 60 cm, a directional uncertainty of 13.2 degrees, and energy reconstruction uncertainty of about 10% for BNB muon neutrino Charged Current Zero Pion (CC0π) events.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of local-power-free, remote α -particle detection using optical fibers

We demonstrate the application of fluorescence optical fiber coupled to a telecom grade fiber as a sensor for alpha particles using alpha-specific ZnS(Ag) scintillation materials whose wavelength is down-shifted into a low-loss region of the telecom grade fiber transmission band. Telecom-grade fiber optics offer a solution for sensing alpha radiation in deep repositories and cask storage for radioactive materials due to the stability of SiO 2 under normal environmental conditions and its relative radiation hardness at low radiation doses. Long-term nuclear waste storage facilities require sensors for the detection of leakage of radioactive materials that are maintenance-free, do not require power and can survive with no ‘wear out’ mechanisms for decades. By accomplishing the wavelength transformation, we maximize efficiencies in the detection of α-particles and signal transport and can detect alpha scintillation at distances on the order of >1 km with a sensor that is ~3% efficient and can be easily scaled as a sensor array. This paper describes the construction and testing of the sensor including manufacture of the controlled thickness films, verification of the wavelength shift from 450 to 620 nm and optimization of the sensitivity as a function of thickness. We also model the relative sensitivity of the film as a function of film thickness, and we demonstrate a signal-to-noise ratio of 10 at a range of greater than 1 km.

alpha particles↗

Strobed imaging as a method for the determination and diagnosis of local seeing

ABSTRACT The image quality budget of many telescopes can have substantial contributions from local seeing, both ‘mirror’ and ‘dome’, which arise from turbulence and temperature variations that are difficult to quantify, measure directly, and ameliorate. We describe a method to determine the ‘local’ seeing degradation due to wavefront perturbations within the final few metres of the optical path from celestial sources to the focal plane of a ground-based telescope, using the primary instrument and along the same path taken by light from celestial sources. The concept involves placing strobed emitters along the light path to produce images on the main focal plane that ‘freeze’ different realizations of index perturbations. This method has the advantage of measuring directly the image motion and scintillation imparted by the dynamic spatial and temporal structure of local perturbations in the index of refraction along the light path, with a clean separation from seeing induced in the atmosphere above the dome. The strobed-source approach allows for rapid image motion and scintillation to be measured directly on the focal plane, even for large-aperture telescopes with wide-field instruments and slow shutters, such as that being constructed for the Rubin Observatory. A conceptual design is presented that uses the ‘guider’ CCDs in the Rubin telescope focal plane to make local-seeing measurements on demand, perhaps even during science exposures.

79 ASTRONOMY AND ASTROPHYSICS↗

Sensitivity of nEXO to 136 Xe charged-current interactions: Background-free searches for solar neutrinos and fermionic dark matter

We study the sensitivity of nEXO to solar neutrino charged-current interactions, 𝜈 𝑒 + 136 Xe → 136 Cs*+𝑒 − , as well as analogous interactions predicted by models of fermionic dark matter. Due to the recently observed low-lying isomeric states of 136 Cs, these interactions will create a time-delayed coincident signal observable in the scintillation channel. Here we develop a detailed Monte Carlo simulation of scintillation emission, propagation, and detection in the nEXO detector to model these signals under different assumptions about the timing resolution of the photosensor readout. We show this correlated signal can be used to achieve background discrimination on the order of 10 −9 , enabling nEXO to make background-free measurements of solar neutrinos above the reaction threshold of 0.668 MeV. We project that nEXO could measure the flux of neutrinos from the carbon-nitrogen-oxygen cycle with a statistical uncertainty of 25%, thus contributing a novel and competitive measurement toward addressing the solar metallicity problem. Additionally, nEXO could measure the mean energy of the 7 Be neutrinos with a precision of 𝜎 ≤ 1.5 keV and could determine the survival probability of 7 Be and pep solar 𝜈𝑒 with precision comparable to the state of the art. These quantities are sensitive to the Sun’s core temperature and to nonstandard neutrino interactions, respectively. Here, the strong background suppression would allow nEXO to search for charged-current interactions of fermionic dark matter in the mass range 𝑚 𝜒 = 0.668–7 MeV with a sensitivity up to three orders of magnitude better than current limits.

47 OTHER INSTRUMENTATION↗

First Event-by-Event Identification of Cherenkov Radiation from Sub-Mev Particles in Liquid Argon

This Letter reports the event-by-event observation of Cherenkov light from sub-MeV electrons in a high scintillation light-yield liquid argon detector by the coherent CAPTAIN-Mills (CCM) experiment. The CCM200 detector, located at Los Alamos National Laboratory, instruments seven tons (fiducial volume) of liquid argon with 200 eight-inch photomultiplier tubes, 80% of which are coated in a wavelength-shifting material and the remaining 20% are uncoated. In the prompt time region of an event, defined as - 6 ≤ t < 0 ns relative to the event start time t = 0 , the uncoated photomultiplier tubes are primarily sensitive to visible Cherenkov photons. Using gamma rays from a Na 22 source for production of sub-MeV electrons, we isolated prompt Cherenkov light with > 5 σ confidence and developed a selection to obtain a low-background electromagnetic sample. This is the first event-by-event observation of Cherenkov photons from sub-MeV electrons in a high-yield scintillator detector and represents a milestone in low-energy particle detector development.

Aguilar-Arevalo, A. A. [UNAM, Mexico]↗

12 C(p,p') 12 C Reaction ( E p =19.5–30 MeV) for Active Interrogation of Special Nuclear Material

Passive detection of special nuclear material (SNM) is challenging due to its inherently low rate of spontaneous emission of penetrating radiation, the relative ease of shielding, and the fluctuating and frequently overwhelming background. Active interrogation, the use of external radiation to increase the emission rate of characteristic radiation from SNM, has long been considered to be a promising method to overcome those challenges. Current active-interrogation systems that incorporate radiography tend to use bremsstrahlung beams, which can deliver high radiation doses. Low-energy ion-driven nuclear reactions that produce multiple monoenergetic photons may be used as an alternative. The 12 C ( p , p ' ) 12 C reaction is one such reaction that could produce large yields of highly penetrating 4.4- and 15.1-MeV gamma rays. This reaction does not directly produce neutrons below the approximately 19.7 MeV threshold, and the 15.1-MeV gamma-ray line is well matched to the photofission cross section of 235 U and 238 U . In this article, we report the measurements of thick-target gamma-ray yields at 4.4 and 15.1 MeV from the 12 C ( p , p ' ) 12 C reaction at proton energies of 19.5, 25, and 30 MeV. Measurements are made with two 3 -in. EJ-309 cylindrical liquid scintillation detectors and thermoluminescent dosimeters placed at 0 ° and 90 ° , with an additional 1.5 -in. Na I ( Tl ) cylindrical scintillation detector at 0 ° . We estimate the highest yields of the 4.4- and 15.1-MeV gamma rays of 1.65 × 10 10 and 4.47 × 10 8 sr - 1 μ C - 1 at a proton energy of 30 MeV, respectively. The yields in all experimental configurations are greater than in a comparable deuteron-driven reaction that produces the same gamma-ray energies— 11 B ( d , n γ ) 12 C . However, a significant increase of the neutron radiation dose accompanies the proton energy increase from 19.5 to 30 MeV.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Measurements and computational analysis of the natural decay of 176 Lu

Background: Mainly because of its long half-life and despite its scientific relevance, spectroscopic measurements of 176 Lu forbidden β decays are very limited and lack formulation of shape factors. A direct precise measurement of its Q value is also presently unreported. In addition, the description of forbidden decays provides interesting challenges for nuclear theory. The comparison of precise experimental results with theoretical calculations for these decays can help to test underlying models and can aid the interpretation of data from other experiments. Purpose: Perform the first precision measurements of 176 Lu β-decay spectra and attempt the observation of its electron capture decays, as well as perform the first precision direct measurement of the 176 Lu β-decay Q value. Compare the shape of the precisely determined experimental β spectra to theoretical calculations, and compare the end point energy to that obtained from an independent Q value measurement. Method: Here, the 176 Lu β-decay spectra measurements and the search for electron capture decays were performed with an experimental setup that employed lutetium-containing scintillator crystals and a NaI(Tl) spectrometer for coincidence counting. The β decay Q value was determined via high-precision Penning trap mass spectrometry (PTMS) with the LEBIT facility at the National Superconducting Cyclotron Laboratory. The β-spectrum calculations were performed within the Fermi theory formalism with nuclear structure effects calculated using a shell model approach. Results: Both β transitions of 176 Lu were experimentally observed and corresponding shape factors formulated in their entire energy ranges. The search for electron capture decay branches led to an experimental upper limit of 6.3×10 –6 relative to its β decays. The 176 Lu β-decay and electron capture Q values were measured using PTMS to be 1193.0(6) and 108.9(8) keV, respectively. This enabled precise β end point energies of 596.2(6) and 195.3(6) keV to be determined for the primary and secondary β decays, respectively. The conserved vector current hypothesis was applied to calculate the relativistic vector matrix elements. The β-spectrum shape was shown to significantly depend on the Coulomb displacement energy and on the value of the axial vector coupling constant gA, which was extracted according to different assumptions. Conclusion: The implemented self-scintillation method has provided unmatched observations of 176 Lu, independently validated by the first direct measurements of its β-decay Q value by Penning trap mass spectrometry. Theoretical study of the main β transition led to the extraction of very different effective gA and log10f values, showing that a high-precision description of this transition would require a realistic nuclear structure with nucleus deformation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of fragment-correlated γ-ray emission from 252 Cf(sf)

This paper presents recent experimental results on the yield of prompt fission γ rays from the spontaneous fission of 252 Cf. We use an ionization chamber to tag fission events and measure the masses and kinetic energies of the fission fragments and trans-stilbene organic scintillators to measure the neutrons and γ rays emitted by the fission fragments. The combination of the ionization chamber and trans-stilbene scintillators allows us to determine the properties of neutrons and γ rays in coincidence with the fragments. The yield of γ rays is known to be influenced by the angular momenta (AM) of the fission fragments. We present experimental evidence indicating that the total γ-ray multiplicity, i.e., the sum of both fragments' emission, saturates at sufficiently high internal fragment excitation energies. We also observe distinct behaviors for the yield of γ rays from the light and heavy fragments, which for certain mass and total kinetic energy (TKE) regions are weakly or anticorrelated, indicating the presence of complex AM generation modes. We also observed a mass- and TKE-dependent anisotropy of the γ rays, which challenges and expands on the conventional notion that the fragments' AM are always aligned perpendicularly to the fission axis. Furthermore, the dependence of the anisotropy on mass and TKE indicates a dependence of these properties on the specific fission channels, thus providing an insight into the deformations and dynamics in fission and their connection with experimentally observable quantities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Feasibility study to use neutron capture for an ultralow energy nuclear-recoil calibration in liquid xenon

The feasibility of an ultra-low energy nuclear-recoil measurement in liquid xenon using neutron capture is investigated for a small (sub-kilogram) liquid xenon detector that is optimized for a high scintillation gain, and a pulsed neutron source. Further, the measurement uses the recoil energies imparted to xenon nuclei during the de-excitation process following neutron capture, where promptly emitted γ cascades can provide the nuclei with up to 0.3 keV nr of recoil energy due to conservation of momentum. A successful calibration of scintillation photon and ionization electron yields below this energy will contribute to a greater sensitivity for liquid xenon experiments in searches for light WIMPs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗