Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SPECTROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Online monitoring of lanthanide species with combined spectroscopy in flowing aqueous aerosol systems

Combined spectroscopic analysis through absorption and laser-induced breakdown spectroscopy (LIBS) was used to monitor Nd and Pr concentrations in a flowing aqueous system. A unique, online sampling approach was employed that allowed for an approximately closed analysis loop of liquids from a reservoir. Absorption spectroscopy was performed with an optical flow cell, and LIBS was performed on an aerosol stream. Multivariate calibrations based on combined absorption and LIBS signals were built for Nd and Pr and then used to monitor concentrations in mixed solutions in a series of spiking tests. In these tests, the concentrations of Nd and Pr in solution were intermittently changed while spectroscopic signals were monitored in real-time. The combined spectroscopic signals and multivariate models were successful in monitoring changing concentrations of lanthanide species with high accuracy and minimal latency. Root-mean squared error of predictions were 0.015 mol L −1 and 0.019 mol L −1 for Nd and Pr respectively, and these lanthanides were able to be monitored to an accuracy of < 0.2 wt%. This work demonstrates both the capabilities of a sampling system for online analysis of liquids and the capabilities of multimodal spectroscopic characterization for real-time, continuous tracking of species in potentially hazardous liquid systems.

absorbance spectroscopy↗

Effect of Mn Substitution for Multiferroic BiFeO3 Probed by High-Resolution Soft-X-Ray Spectroscopy

The electronic structures of BiFeO{sub 3} (BF) and Mn-doped BiFeO{sub 3} (BF(Mn)) have been studied by X-ray absorption spectroscopy (XAS) and soft-X-ray emission spectroscopy (SXES). The BF and BF(Mn) have the mixed valence state of Fe{sup 2+} and Fe{sup 3+}. The valence band is mainly composed of O 2p state hybridized with the majority-spin t{sub 2g} and e{sub g} orbitals of Fe 3d state. The conduction band is composed of the minority-spin t{sub 2g} and e{sub g} orbitals of Fe 3d. The band gaps of BF and BF(Mn) are estimated to be 1.3 eV and 2.7 eV, respectively. The increase of band gap with Mn substitution contributes to the change of bandwidth of valence band.

36 MATERIALS SCIENCE↗

High quality x-ray absorption spectroscopy measurements with long energy range at high pressure using diamond anvil cell

We describe an approach for acquiring high quality x-ray absorption fine structure (XAFS) spectroscopy spectra with wide energy range at high pressure using diamond anvil cell (DAC). Overcoming the serious interference of diamond Bragg peaks is essential for combining XAFS and DAC techniques in high pressure research, yet an effective method to obtain accurate XAFS spectrum free from DAC induced glitches has been lacking. It was found that these glitches, whose energy positions are very sensitive to the relative orientation between DAC and incident x-ray beam, can be effectively eliminated using an iterative algorithm based on repeated measurements over a small angular range of DAC orientation, e.g., within {+-}3{sup o} relative to the x-ray beam direction. Demonstration XAFS spectra are reported for rutile-type GeO{sub 2} recorded by traditional ambient pressure and high pressure DAC methods, showing similar quality at 440 eV above the absorption edge. Accurate XAFS spectra of GeO{sub 2} glass were obtained at high pressure up to 53 GPa, providing important insight into the structural polymorphism of GeO{sub 2} glass at high pressure. This method is expected be applicable for in situ XAFS measurements using a diamond anvil cell up to ultrahigh pressures.

36 MATERIALS SCIENCE↗

Annealing effects of in-depth profile and band discontinuity in TiN/LaO/HfSiO/SiO{sub 2}/Si gate stack structure studied by angle-resolved photoemission spectroscopy from backside

We have investigated annealing effects on in-depth profile and band discontinuity for a metal gate/high-k gate stack structure on a Si substrate using backside angle-resolved photoemission spectroscopy with synchrotron radiation. In-depth profiles analyzed from angle-resolved photoemission spectroscopy show that La atoms diffuse through the HfSiO layer and reach interfacial SiO{sub 2} layers by rapid thermal annealing. Chemical shift of Si 2p core-level spectra suggests that there are changes in the band discontinuity at the high-k/SiO{sub 2} interface, which is well related to the V{sub th} shift based on the interface dipole model.

36 MATERIALS SCIENCE↗

Polarization Raman spectroscopy of GaN nanorod bundles

We performed polarization Raman spectroscopy on single wurtzite GaN nanorod bundles grown by plasma-assisted molecular beam epitaxy. The obtained Raman spectra were compared with those of GaN epilayer. The spectral difference between the GaN nanorod bundles and epilayer reveals the relaxation of Raman selection rules in these GaN nanorod bundles. The deviation of polarization-dependent Raman spectroscopy from the prediction of Raman selection rules is attributed to both the orientation of the crystal axis with respect to the polarization vectors of incident and scattered light and the structural defects in the merging boundary of GaN nanorods. The presence of high defect density induced by local strain at the merging boundary was further confirmed by transmission electron microscopy. The averaged defect interspacing was estimated to be around 3 nm based on the spatial correlation model.

36 MATERIALS SCIENCE↗

Composition and strain in thin Si{sub 1-x}Ge{sub x} virtual substrates measured by micro-Raman spectroscopy and x-ray diffraction

Micro-Raman spectroscopy was employed for the determination of the germanium content, x and strain, {epsilon}, in ultrathin SiGe virtual substrates grown directly on Si by molecular beam epitaxy. The growth of highly relaxed SiGe layers was achieved by the introduction of point defects at a very low temperature during the initial stage of growth. SiGe virtual substrates with thicknesses in the range 40-200 nm with a high Ge content (up to 50%) and degree of relaxation, r, in the range 20%-100% were investigated using micro-Raman spectroscopy and x-ray diffraction (XRD) techniques. The Ge content, x, and strain, {epsilon}, were estimated from equations describing Si-Si, Si-Ge, and Ge-Ge Raman vibrational modes, modified in this study for application to thin SiGe layers. The alteration of the experimentally derived equations from previous studies was performed using independent data for x and r obtained from XRD reciprocal space maps. A number of samples consisting of a strained-silicon (s-Si) layer deposited on a SiGe virtual substrate were also analyzed. The stress value for the s-Si varied from 0.54 to 2.75 GPa, depending on the Ge-content in the virtual substrates. These results are in good agreement with theoretically predicted values.

36 MATERIALS SCIENCE↗

Study of the Thermal Behavior of Syndiotactic and Atactic Polystyrene By Raman Spectroscopy

The glass properties and semi crystalline properties of polymers are observable by X-ray diffraction. Some previous works 1, 2, 3 were about determination of degree of crystallinity of sPS by various technologies, like for example DSC, XRD and Raman spectroscopy. The purpose of this paper is to show importance of Raman spectroscopy as analytical tool for the study of amorphous and semi-crystalline phase. The polymers on which our research is achieved, is amorphous polystyrene, shortened aPS, and semi crystalline polystyrene, sPS.

36 MATERIALS SCIENCE↗

High energy resolution five-crystal spectrometer for high quality fluorescence and absorption measurements on an x-ray absorption spectroscopy beamline

Fluorescence detection is classically achieved with a solid state detector (SSD) on x-ray absorption spectroscopy (XAS) beamlines. This kind of detection however presents some limitations related to the limited energy resolution and saturation. Crystal analyzer spectrometers (CAS) based on a Johann-type geometry have been developed to overcome these limitations. We have tested and installed such a system on the BM30B/CRG-FAME XAS beamline at the ESRF dedicated to the structural investigation of very dilute systems in environmental, material and biological sciences. The spectrometer has been designed to be a mobile device for easy integration in multi-purpose hard x-ray synchrotron beamlines or even with a laboratory x-ray source. The CAS allows to collect x-ray photons from a large solid angle with five spherically bent crystals. It will cover a large energy range allowing to probe fluorescence lines characteristic of all the elements from Ca (Z = 20) to U (Z = 92). It provides an energy resolution of 1-2 eV. XAS spectroscopy is the main application of this device even if other spectroscopic techniques (RIXS, XES, XRS, etc.) can be also achieved with it. The performances of the CAS are illustrated by two experiments that are difficult or impossible to perform with SSD and the complementarity of the CAS vs SSD detectors is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of electronic structure of amorphous InGaZnO/SiO{sub 2} interface by angle-resolved X-ray photoelectron spectroscopy

The electronic structures of amorphous indium gallium zinc oxide (a-IGZO) on a SiO{sub 2} layers before and after annealing were observed by constant final state X-ray photoelectron spectroscopy (CFS-XPS) and X-ray adsorption near-edge structure spectroscopy (XANES). From the results of angle-resolved CFS-XPS, the change in the electronic state was clearly observed in the a-IGZO bulk rather than in the a-IGZO/SiO{sub 2} interface. This suggests that the electronic structures of the a-IGZO bulk strongly affected the thin-film transistor characteristics. The results of XANES indicated an increase in the number of tail states upon atmospheric annealing (AT). We consider that the increase in the number of tail states decreased the channel mobility of AT samples.

36 MATERIALS SCIENCE↗

Performance and characteristics of a high pressure, high temperature capillary cell with facile construction for operando x-ray absorption spectroscopy

We demonstrate the use of commercially available fused silica capillary and fittings to construct a cell for operando X-ray absorption spectroscopy (XAS) for the study of heterogeneously catalyzed reactions under high pressure (up to 200 bars) and high temperature (up to 280 °C) conditions. As the first demonstration, the cell was used for CO{sub 2} hydrogenation reaction to examine the state of copper in a conventional Cu/ZnO/Al{sub 2}O{sub 3} methanol synthesis catalyst. The active copper component of the catalyst was shown to remain in the metallic state under supercritical reaction conditions, at 200 bars and up to 260 °C. With the coiled heating system around the capillary, one can easily change the length of the capillary and control the amount of catalyst under investigation. With precise control of reactant(s) flow, the cell can mimic and serve as a conventional fixed-bed micro-reactor system to obtain reliable catalytic data. This high comparability of the reaction performance of the cell and laboratory reactors is crucial to gain insights into the nature of actual active sites under technologically relevant reaction conditions. The large length of the capillary can cause its bending upon heating when it is only fixed at both ends because of the thermal expansion. The degree of the bending can vary depending on the heating mode, and solutions to this problem are also presented. Furthermore, the cell is suitable for Raman studies, nowadays available at several beamlines for combined measurements. A concise study of CO{sub 2} phase behavior by Raman spectroscopy is presented to demonstrate a potential of the cell for combined XAS-Raman studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In situ Raman spectroscopy for growth monitoring of vertically aligned multiwall carbon nanotubes in plasma reactor

Portable and highly sensitive Raman setup was associated with a plasma-enhanced chemical vapor deposition reactor enabling in situ growth monitoring of multi-wall carbon nanotubes despite the combination of huge working distance, high growth speed and process temperature and reactive plasma condition. Near Edge X-ray absorption fine structure spectroscopy was used for ex situ sample analysis as a complementary method to in situ Raman spectroscopy. The results confirmed the fact that the “alternating” method developed here can accurately be used for in situ Raman monitoring under reactive plasma condition. The original analytic tool can be of great importance to monitor the characteristics of these nanostructured materials and readily define the ultimate conditions for targeted results.

36 MATERIALS SCIENCE↗

An in situ sample environment reaction cell for spatially resolved x-ray absorption spectroscopy studies of powders and small structured reactors

An easy-to-use sample environment reaction cell for X-ray based in situ studies of powders and small structured samples, e.g., powder, pellet, and monolith catalysts, is described. The design of the cell allows for flexible use of appropriate X-ray transparent windows, shielding the sample from ambient conditions, such that incident X-ray energies as low as 3 keV can be used. Thus, in situ X-ray absorption spectroscopy (XAS) measurements in either transmission or fluorescence mode are facilitated. Total gas flows up to about 500 ml{sub n}/min can be fed while the sample temperature is accurately controlled (at least) in the range of 25–500 °C. The gas feed is composed by a versatile gas-mixing system and the effluent gas flow composition is monitored with mass spectrometry (MS). These systems are described briefly. Results from simultaneous XAS/MS measurements during oxidation of carbon monoxide over a 4% Pt/Al{sub 2}O{sub 3} powder catalyst are used to illustrate the system performance in terms of transmission XAS. Also, 2.2% Pd/Al{sub 2}O{sub 3} and 2% Ag − Al{sub 2}O{sub 3} powder catalysts have been used to demonstrate X-ray absorption near-edge structure (XANES) spectroscopy in fluorescence mode. Further, a 2% Pt/Al{sub 2}O{sub 3} monolith catalyst was used ex situ for transmission XANES. The reaction cell opens for facile studies of structure-function relationships for model as well as realistic catalysts both in the form of powders, small pellets, and coated or extruded monoliths at near realistic conditions. The applicability of the cell for X-ray diffraction measurements is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A flexible gas flow reaction cell for in situ x-ray absorption spectroscopy studies

A capillary-based sample environment with hot air blower and integrated gas system was developed at Diamond to conduct X-ray absorption spectroscopy (XAS) studies of materials under time-resolved, in situ conditions. The use of a hot air blower, operating in the temperature range of 298-1173 K, allows introduction of other techniques e.g. X-ray diffraction (XRD), Raman spectroscopy for combined techniques studies. The flexibility to use either quartz or Kapton capillaries allows users to perform XAS measurement at energies as low as 5600 eV. To demonstrate performance, time-resolved, in situ XAS results of Rh catalysts during the process of activation (Rh K-edge, Ce L{sub 3}-edge and Cr K-edge) and the study of mixed oxide membrane (La{sub 0.6}Sr{sub 0.4}Co{sub 0.2}Fe{sub 0.8}O{sub 3−δ}) under various partial oxygen pressure conditions are described.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Solution phase high repetition rate laser pump x-ray probe picosecond hard x-ray spectroscopy at the Stanford Synchrotron Radiation Lightsource

We present a dedicated end-station for solution phase high repetition rate (MHz) picosecond hard x-ray spectroscopy at beamline 15-2 of the Stanford Synchrotron Radiation Lightsource. A high-power ultrafast ytterbium-doped fiber laser is used to photoexcite the samples at a repetition rate of 640 kHz, while the data acquisition operates at the 1.28 MHz repetition rate of the storage ring recording data in an alternating on-off mode. The time-resolved x-ray measurements are enabled via gating the x-ray detectors with the 20 mA/70 ps camshaft bunch of SPEAR3, a mode available during the routine operations of the Stanford Synchrotron Radiation Lightsource. As a benchmark study, aiming to demonstrate the advantageous capabilities of this end-station, we have conducted picosecond Fe K-edge x-ray absorption spectroscopy on aqueous [FeII(phen)3]2+, a prototypical spin crossover complex that undergoes light-induced excited spin state trapping forming an electronic excited state with a 0.6–0.7 ns lifetime. In addition, we report transient Fe Kβ main line and valence-to-core x-ray emission spectra, showing a unique detection sensitivity and an excellent agreement with model spectra and density functional theory calculations, respectively. Notably, the achieved signal-to-noise ratio, the overall performance, and the routine availability of the developed end-station have enabled a systematic time-resolved science program using the monochromatic beam at the Stanford Synchrotron Radiation Lightsource.

47 OTHER INSTRUMENTATION↗

Characterization of an RF-driven argon plasma at atmospheric pressure using broadband absorption and optical emission spectroscopy

Atmospheric pressure plasmas in argon are of particular interest due to the production of highly excited and reactive species enabling numerous plasma-aided applications. In this contribution, we report on absolute optical emission and absorption spectroscopy of a radio frequency (RF) driven capacitively coupled argon glow discharge operated in a parallel-plate configuration. This enabled the study of all key parameters including electron density and temperature, gas temperature, and absolute densities of atoms in highly electronically excited states. The space and time-averaged electron density and temperature were determined from the measurement of the absolute intensity of the electron-atom bremsstrahlung in the visible range. Considering the non-Maxwellian electron energy distribution function, an electron temperature (T e ) of 2.1 eV and an electron density (n e ) of 1.1 × 10 19 m –3 were obtained. The time-averaged and spatially resolved absolute densities of atoms in the metastable (1s 5 and 1s 3 ) and resonant (1s 4 and 1s 2 ) states of argon in pure Ar and Ar/He mixture were obtained by broadband absorption spectroscopy. The 1s 5 metastable atoms had the largest density near the sheath region with a maximum value of 8 × 10 17 m –3 , while all other 1s states had densities of at most 2 × 10 17 m –3 . Here, the dominant production and loss mechanisms of these atoms were discussed, in particular, the role of radiation trapping. We conclude with a comparison of the plasma properties of the argon RF glow discharges with the more common He equivalent and highlight their differences.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Probing electrolyte–silica interactions through simulations of the infrared spectroscopy of nanoscale pores

The structural and dynamical properties of nanoconfined solutions can differ dramatically from those of the corresponding bulk systems. Understanding the changes induced by confinement is central to controlling the behavior of synthetic nanostructured materials and predicting the characteristics of biological and geochemical systems. A key outstanding issue is how the molecular-level behavior of nanoconfined electrolyte solutions is reflected in different experimental, particularly spectroscopic, measurements. This is addressed here through molecular dynamics simulations of the OH stretching infrared (IR) spectroscopy of NaCl, NaBr, and NaI solutions in isotopically dilute HOD/D 2 O confined in hydroxylated amorphous silica slit pores of width 1–6 nm and pH ~2. In addition, the water reorientation dynamics and spectral diffusion, accessible by pump–probe anisotropy and two-dimensional IR measurements, are investigated. In this work, the aim is to elucidate the effect of salt identity, confinement, and salt concentration on the vibrational spectra. It is found that the IR spectra of the electrolyte solutions are only modestly blue-shifted upon confinement in amorphous silica slit pores, with both the size of the shift and linewidth increasing with the halide size, but these effects are suppressed as the salt concentration is increased. This indicates the limitations of linear IR spectroscopy as a probe of confined water. However, the OH reorientational and spectral diffusion dynamics are significantly slowed by confinement even at the lowest concentrations. The retardation of the dynamics eases with increasing salt concentration and pore width, but it exhibits a more complex behavior as a function of halide.

Mesoporous material↗

Implementation of extreme ultraviolet spectroscopy on a sheared-flow-stabilized Z pinch

A diagnostic for extreme ultraviolet spectroscopy was fielded on the sheared-flow-stabilized (SFS) fusion Z-pinch experiment (FuZE-Q) for the first time. The spectrometer collected time-gated plasma emission spectra in the 5–40 nm wavelength (30–250 eV) range for impurity identification, radiative power studies, and for plasma temperature and density measurements. The unique implementation of the diagnostic included fast (10 ns risetime) pulsed high voltage electronics and a multi-stage differential pumping system that allowed the vacuum-coupled spectrometer to collect three independently timed spectra per FuZE-Q shot while also protecting sensitive internal components. Analysis of line emission identifies oxygen (N-, C-, B-, Be-, Li-, and He-like O), peaking in intensity shortly after maximum current (>500 kA). This work provides a foundation for future high energy spectroscopy experiments on SFS Z-pinch devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and performance of a magnetic bottle electron spectrometer for high-energy photoelectron spectroscopy

We describe the design and performance of a magnetic bottle electron spectrometer (MBES) for high-energy electron spectroscopy. Our design features a 2 m long electron drift tube and electrostatic retardation lens, achieving sub-electronvolt (eV) electron kinetic energy resolution for high energy (several hundred eV) electrons with a close to 4π collection solid angle. A segmented anode electron detector enables the simultaneous collection of photoelectron spectra in high resolution and high collection efficiency modes. This versatile instrument is installed at the time-resolved molecular and optical sciences instrument at the Linac Coherent Light Source x-ray free-electron laser (XFEL). In this paper, we demonstrate its high resolution, collection efficiency, and spatial selectivity in measurements where it is coupled to an XFEL source. These combined characteristics are designed to enable high-resolution time-resolved measurements using x-ray photoelectron, absorption, and Auger–Meitner spectroscopy. We also describe the pervasive artifact in MBES time-of-flight spectra that arises from a periodic modulation in electron collection efficiency and present a robust analysis procedure for its removal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗