At least 1,153 records · Page 64

Cryogenic Boil-Off Reduction System Testing

The Cryogenic Boil-Off Reduction System was tested with LH2 and LOX in a vacuum chamber to simulate space vacuum and the temperatures of low Earth orbit. Testing was successful and results validated the scaling study model that predicts active cooling reduces upper stage cryogenic propulsion mass for loiter periods greater than 2 weeks.

Zero Boil-Off↗

Solar Thermal Vacuum Test of Deployable Astromesh Reflector

On September 10, 2008, a 36-hour Solar Thermal Vacuum Test of a 5m deployable mesh reflector was completed in JPL's 25' Space Simulator by the Advanced Deployable Structures Group at JPL. The testing was performed under NASA's Innovative Partnership Program (IPP) as a risk reduction effort for two JPL Decadal Survey Missions: DESDynI and SMAP. The 5.0 m aperture Astromesh reflector was provided by Northrop Grumman Aerospace Systems (NGAS) Astro Aerospace, our IPP industry partner. The testing utilized a state-of-the-art photogrammetry system to measure deformation of the reflector under LN2 cold soak, 0.25 Earth sun, 0.5 sun and 1.0 sun. An intricate network of thermocouples (approximately 200 in total) was used to determine the localized temperature across the mesh as well as on the perimeter truss of the reflector. Half of the reflector was in a fixed shadow to maximize thermal gradients. A mobility system was built for remotely actuating the cryo-vacuum capable photogrammetry camera around the circumference of the Solar Simulator. Photogrammetric resolution of 0.025 mm RMS (0.001") was achieved over the entire 5 meter aperture for each test case. The data will be used for thermo-elastic model correlation and validation, which will benefit the planned Earth Science Missions.

Photogrammetry↗

Plume Characterization of a Laboratory Model 22 N GPIM Thruster via High-Frequency Raman Spectroscopy

The Green Propellant Infusion Mission (GPIM) will demonstrate the capability of a green propulsion system, specifically, one using the monopropellant, AF-M315E. One of the risks identified for GPIM is potential contamination of sensitive areas of the spacecraft from the effluents in the plumes of AF-M315E thrusters. Plume characterization of a laboratory-model 22 N thruster via optical diagnostics was conducted at NASA GRC in a space-simulated environment. A high-frequency pulsed laser was coupled with an electron-multiplied ICCD camera to perform Raman spectroscopy in the near-field, low-pressure plume. The Raman data yielded plume constituents and temperatures over a range of thruster chamber pressures and as a function of thruster (catalyst) operating time. Schlieren images of the near-field plume enabled calculation of plume velocities and revealed general plume structure of the otherwise invisible plume. The measured velocities are compared to those predicted by a two-dimensional, kinetic model. Trends in data and numerical results are presented from catalyst mid-life to end-of-life. The results of this investigation were coupled with the Raman and Schlieren data to provide an anchor for plume impingement analysis presented in a companion paper. The results of both analyses will be used to improve understanding of the nature of AF-M315E plumes and their impacts to GPIM and other future missions.

Raman Spectroscopy↗

Investigation of Vapor Cooling Enhancements for Applications on Large Cryogenic Systems

The need to demonstrate and evaluate the effectiveness of heat interception methods for use on a relevant cryogenic propulsion stage at a system level has been identified. Evolvable Cryogenics (eCryo) Structural Heat Intercept, Insulation and Vibration Evaluation Rig (SHIIVER) will be designed with vehicle specific geometries (SLS Exploration Upper Stage (EUS) as guidance) and will be subjected to simulated space environments. One method of reducing structure-born heat leak being investigated utilizes vapor-based heat interception. Vapor-based heat interception could potentially reduce heat leak into liquid hydrogen propulsion tanks, increasing potential mission length or payload capability. Due to the high number of unknowns associated with the heat transfer mechanism and integration of vapor-based heat interception on a realistic large-scale skirt design, a sub-scale investigation was developed. The sub-project effort is known as the Small-scale Laboratory Investigation of Cooling Enhancements (SLICE). The SLICE aims to study, design, and test sub-scale multiple attachments and flow configuration concepts for vapor-based heat interception of structural skirts. SLICE will focus on understanding the efficiency of the heat transfer mechanism to the boil-off hydrogen vapor by varying the fluid network designs and configurations. Various analyses were completed in MATLAB, Excel VBA, and COMSOL Multiphysics to understand the optimum flow pattern for heat transfer and fluid dynamics. Results from these analyses were used to design and fabricate test article subsections of a large forward skirt with vapor cooling applied. The SLICE testing is currently being performed to collect thermal mechanical performance data on multiple skirt heat removal designs while varying inlet vapor conditions necessary to intercept a specified amount of heat for a given system. Initial results suggest that applying vapor-cooling provides a 50 heat reduction in conductive heat transmission along the skirt to the tank. The information obtained by SLICE will be used by the SHIIVER engineering team to design and implement vapor-based heat removal technology into the SHIIVER forward skirt hardware design.

small scale testing↗

Modernization of NASA's Johnson Space Center Chamber: A Liquid Nitrogen System to Support Cryogenic Vacuum Optical Testing of the James Webb Space Telescope (JWST)

NASA is the mission lead for the James Webb Space Telescope (JWST), the next of the “Great Observatories”, scheduled for launch in 2018. It is directly responsible for the integration and test (I&T) program that will culminate in an end-to-end cryo vacuum optical test of the flight telescope and instrument module in Chamber A at NASA Johnson Space Center. Historic Chamber A is the largest thermal vacuum chamber at Johnson Space Center and one of the largest space simulation chambers in the world. Chamber A has undergone a major modernization effort to support the deep cryogenic, vacuum and cleanliness requirements for testing the JWST. This paper describes the steps performed in efforts to convert the existing the 60’s era Liquid Nitrogen System from a forced flow (pumped) process to a natural circulation (thermo-siphon) process. In addition, the paper will describe the dramatic conservation of liquid nitrogen to support the long duration thermal vacuum testing. Lastly, describe the simplistic and effective control system which results in zero to minimal human inputs during steady state conditions.

Garcia, Sammy↗

Machine Learning Approaches to Increasing Value of Spaceflight Omics Databases

The number of spaceflight bioscience mission opportunities is too small to allow all relevant biological and environmental parameters to be experimentally identified. Simulated spaceflight experiments in ground-based facilities (GBFs), such as clinostats, are each suitable only for particular investigations -- a rotating-wall vessel may be 'simulated microgravity' for cell differentiation (hours), but not DNA repair (seconds) -- and introduce confounding stimuli, such as motor vibration and fluid shear effects. This uncertainty over which biological mechanisms respond to a given form of simulated space radiation or gravity, as well as its side effects, limits our ability to baseline spaceflight data and validate mission science. Machine learning techniques autonomously identify relevant and interdependent factors in a data set given the set of desired metrics to be evaluated: to automatically identify related studies, compare data from related studies, or determine linkages between types of data in the same study. System-of-systems (SoS) machine learning models have the ability to deal with both sparse and heterogeneous data, such as that provided by the small and diverse number of space biosciences flight missions; however, they require appropriate user-defined metrics for any given data set. Although machine learning in bioinformatics is rapidly expanding, the need to combine spaceflight/GBF mission parameters with omics data is unique. This work characterizes the basic requirements for implementing the SoS approach through the System Map (SM) technique, a composite of a dynamic Bayesian network and Gaussian mixture model, in real-world repositories such as the GeneLab Data System and Life Sciences Data Archive. The three primary steps are metadata management for experimental description using open-source ontologies, defining similarity and consistency metrics, and generating testing and validation data sets. Such approaches to spaceflight and GBF omics data may soon enable unique insight into which measured phenomena correlate to biological mechanisms that are truly affected by spaceflight conditions; which are most likely to be confounded by other variables; and which are insufficiently characterized, significantly increasing existing and future science return from ISS and spaceflight missions.

Gentry, Diana↗

Deleterious Effects of Simulated Spaceflight on Bone and Microvasculature in Adult Mice

Long-term spaceflight leads to extensive changes in the musculoskeletal system attributable, in part, to unloading during microgravity exposure. Additionally, irradiation at doses similar to that of a solar flare or a round-trip sojourn to Mars may cause significant depletion of stem/progenitor cell pools throughout the body as well as inflammation associated with prompt skeletal-tissue degradation. Previously, we demonstrated that irradiation leads to rapid bone loss, which can be mitigated in the short term by injection of a potent antioxidant (-lipoic acid). Furthermore, simulated weightlessness in adult mice adversely affects skeletal responses to low linear energy transfer (LET) radiation (137Cs). Here, we hypothesized that simulated weightlessness exacerbates the adverse effects of simulated space radiation (including both protons and 56Fe ions) by adversely affecting skeletal structure and functions as well as associated vasculature. Furthermore, we hypothesized that an antioxidant cocktail, which has been shown to be protective in other tissues, mitigates space radiation induced bone loss.

Shirazi-Fard, Y.↗

Creating the Required Deep Space Environments for Testing the James Webb Space Telescope (JWST) at NASA Johnson Space Center's Chamber A

NASA is the mission lead for the James Webb Space Telescope (JWST), the next of the "Great Observatories", scheduled for launch in 2021. NASA was directly responsible for the integration and test (I&T) program that culminated in an end-to-end cryo vacuum optical test of the flight telescope and instrument module in Chamber A at NASA Johnson Space Center. Historic Chamber A is the largest thermal vacuum chamber at Johnson Space Center and one of the largest space simulation chambers in the world. Chamber A has undergone a major modernization effort to support the deep cryogenic, vacuum and cleanliness requirements for testing the JWST. This paper will discuss the thermal vacuum test of the Optical Telescope Element (OTE) plus Integrated Science Instrument Module (ISIM) (OTIS) as well as the extensive series of tests that were performed to incrementally validate the operations and performance of the Chamber and Ground Support Equipment (GSE). Each test required a unique thermal vacuum profile for cool down and warm up, steady state operations, GSE testing and contamination control. Select results will be presented on Facility Functional Testing, Chamber Bake-out, GSE Cryo-Proof Testing, Chamber Commissioning, the Optical Ground Support Equipment (OGSE) Test series and the final thermal vacuum test of the OTIS with respect to facility operations to meet JWST program test requirements.

Francis, Andrew↗

Generation of Mars Helicopter Rotor Model for Comprehensive Analyses

The present research is aimed at providing a performance model for the Mars Helicopter (MH), to understand the complexity of the flow, and identify future regions of improvement. The low density of the Martian atmosphere and the relatively small MH rotor, result in very low chord-based Reynolds number flows. The low density and Reynolds numbers reduce the lifting force and lifting efficiency, respectively. The high drag coefficients in subcritical flow, especially for thicker sections, are attributed to laminar separation from the rear of the airfoil. In the absence of test data, efforts have been made to explore these effects using prior very low Reynolds number research efforts. The rotor chord-based Reynolds number range is observed to be subcritical, which makes boundary layer transition unlikely to occur. The state of the two-dimensional rotor boundary layer in hover is approximated by calculating the instability point, laminar separation point, and the transition location to provide understanding of the flow state in the high Mach-low Reynolds number regime. The results are used to investigate the need for turbulence modeling in Computational Fluid Dynamics (CFD) calculations afterwards. The goal is to generate a performance model for the MH rotor for a free wake analysis, because the computational budget for a complete Navier-Stokes solution for a rotating body-fitted rotor is substantial. In this study, a Reynolds-Averaged Navier-Stokes (RANS) based approach is used to generate the airfoil deck using C81Gen with stitched experimental data for very high angles of attack. A full Grid Resolution Study is performed and over 4,500 cases are completed to create the full airfoil deck. The laminar separation locations are predicted within the accuracy of the approximate method when compared with the CFD calculations. The model is presented through airfoil data tables (c81 files) that are used by comprehensive rotor analysis codes such as CAMRADII, or the mid-fidelity CFD solver RotCFD. Finally, the rotor performance is compared with experimental data from the 25ft Space Simulator at the NASA Jet Propulsion Laboratory (JPL) and shows good correlation for the rotor Figure of Merit over the available thrust range.

Model↗

Transient Heater Analysis for Orion Thermal Vacuum Testing

The Space Environments Complex (SEC) at NASA's Plum Brook Station is currently being prepared to perform thermal vacuum testing of the Orion spacecraft. This thermal vacuum, or T-VAC test will be run for a period of 60 days, which will be the longest such test ever conducted at SEC. The Orion Crew Module (CM) and Service Module (SM) will undergo T-VAC testing in SEC's Space Simulation Vacuum Chamber to ensure the functionality of these systems in a high vacuum environment at extremely cold temperatures. The T-VAC test setup in SEC was modeled and simulated in Thermal Desktop. The initial results from thermal analysis showed areas on the chamber floor to reach very low temperatures, which were below the minimum operating range of certain hardware located on or near the chamber floor. These hardware including elastomeric seals on the GN2 piping, bearing pads and O-rings are essential to both test and the operation of the SEC facility, and must be kept well above -20°F throughout the duration of the T-VAC test. Thus, further analysis was conducted to include the placement of patch heaters on the chamber floor in an effort to increase the temperature near colder areas on the floor. The results and findings from this analysis showed that using these heaters will result in a favorable temperature distribution on the chamber floor. This paper will discuss the methods used in the analysis, and the results obtained to determine the optimal configuration of these heaters on the chamber floor.

Wilhite, Jarred↗

Transient Heater Analysis for Orion Thermal Vacuum Testing

The Space Environments Complex (SEC) at NASA’s Plum Brook Station is currently being prepared to perform thermal vacuum testing of the Orion spacecraft. This thermal vacuum, or T-VAC test will be run for a period of 60 days, which will be the longest such test ever conducted at SEC. The Orion Crew Module (CM) and Service Module (SM) will undergo T-VAC testing in SEC’s Space Simulation Vacuum Chamber to ensure the functionality of these systems in a high vacuum environment at extremely cold temperatures. The T-VAC test setup in SEC was modeled and simulated in Thermal Desktop. The initial results from thermal analysis showed areas on the chamber floor to reach very low temperatures, which were below the minimum operating range of certain hardware located on or near the chamber floor. These hardware including elastomeric seals on the GN2 piping, bearing pads and O-rings are essential to both test and the operation of the SEC facility, and must be kept well above -20°F throughout the duration of the T-VAC test. Thus, further analysis was conducted to include the placement of patch heaters on the chamber floor in an effort to increase the temperature near colder areas on the floor. The results and findings from this analysis showed that using these heaters will result in a favorable temperature distribution on the chamber floor. This paper will discuss the methods used in the analysis, and the results obtained to determine the optimal configuration of these heaters on the chamber floor.

Wilhite, Jarred↗

Thermal Modeling and Correlation of the Space Environments Complex Vacuum Chamber and Cryoshroud

From Presentation: Formerly known as the Space Power Facility (SPF) Located at Plum Brook Station in Sandusky, OH -- Houses large-scale test facilities including the Space Simulation Vacuum Chamber -- Largest vacuum chamber in the world -- 100 ft diameter, 122 ft tall -- Cryoshroud operates between -250 °F and +140 °F -- To be used for Orion EM-1 thermal vacuum test -- Thermal Desktop model of vacuum chamber, cryoshroud, mechanical ground support equipment (MGSE) including fluid model of GN2 -- Primary uses: Predict MGSE temperatures; Predict heat load on GN2 system -- Includes 96 TD Temperature Measures that represent test thermocouples -- Steady state correlation with 3 tests: 2 hot; 1 cold -- Two ISTs performed with no MGSE inside the cryoshroud: Insulated test: operated at 170 °F for 37 hours; Uninsulated test: operated at 170 °F for 14 days -- Only cryoshroud thermocouples were installed

Thermal modeling↗

ExMC Approach to Pharmaceutical Stability Research: An Overview

Goals of Stability Studies: Identify medications that are stable under real and simulated space conditions, especially deep space radiation; Identify medications that are potent and safe after their expiration dates; Ultimately provide a safe and effective formulary for exploratory spaceflight missions. ExMC: Exploration Medical Capabilities.

Cory, Wendy↗

Science Driven By Space Biology Omics Data Utilizing NASA's GeneLab Platform

Determining the biological impact of spaceflight through novel approaches is essential to reduce the health risks to astronauts for long-term space missions. The current established health risks due to spaceflight are only reflecting known symptomatic and physiologic responses and do not reflect early onset of other potential diseases. There are many unknown variables which still need to be identified to fully understand the health impacts due to the environmental factors in space. One method to uncover potential novel biological mechanisms responsible for health risks in astronauts is by utilizing NASA's GeneLab Data Systems (genelab.nasa.gov). GeneLab is public repository that hosts multiple omics datasets generated from space biology experiments that include experiments flown in space, simulated cosmic radiation.

Beheshti, Afshin↗

An Examination of Heater Bar Outgassing

Presentation for AIAA Space Simulation Working Group that shows the concern about outgassing from heater bars and how the outgassing was mitigated using an outgassing characterization test, followed by a high-vacuum bake out. Some test results are shown from the bake-out and the subsequent Integrated Facility Systems Test.

Reed, Erin↗

Results of Use of Heat Flux Sensors on Liquid Hydrogen Tanks

Heat flux sensors were used to characterize the performance of insulation on the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER), a large-scale test article designed to simulate upper stage cryogenic propellant tank thermal performance in simulated space environments. Usually, the insulation heat loads are derived from calculations removing all other heat sources and attributing the residual heat load to the insulation system. Testing for SHIIVER included the tank being just insulated with spray-on-foam insulation as well as covering the domes with multilayer insulation while leaving the barrel section insulated with spray-on-foam. Heat flux sensors were located at multiple locations on both domes as well as on the barrel section of the tank. Results from the SHIIVER testing using the heat flux sensors are compared to other calculated heat inputs for both liquid nitrogen and liquid hydrogen testing as a function of tank fill level. Further investigation into the transient nature of the SHIIVER testing including the heat flux sensors provided insight into heat flow patterns that may not have been otherwise seen using temperature sensors and calculated insulation heat loads. While the demonstrated uncertainties in the absolute values in the heat flux sensors are high, the values and the trends match well with other calculation methods. The results of SHIIVER allow for the use of heat flux sensors for measurements of insulation performance and dynamic system thermal response for future applications.

Cryogenic Fluid Management↗

Results of Use of Heat Flux Sensors on Liquid Hydrogen Tanks

ABSTRACT: Heat flux sensors were used to characterize the performance of insulation on the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER), a large-scale test article designed to simulate upper stage cryogenic propellant tank thermal performance in simulated space environments. Usually, the insulation heat loads are derived from calculations removing all other heat sources and attributing the residual heat load to the insulation system. Testing for SHIIVER included the tank being just insulated with spray-on-foam insulation as well as covering the domes with multilayer insulation while leaving the barrel section insulated with spray-on-foam. Heat flux sensors were located at multiple locations on both domes as well as on the barrel section of the tank. Results from the SHIIVER testing using the heat flux sensors are compared to other calculated heat inputs for both liquid nitrogen and liquid hydrogen testing as a function of tank fill level. Further investigation into the transient nature of the SHIIVER testing including the heat flux sensors provided insight into heat flow patterns that may not have been otherwise seen using temperature sensors and calculated insulation heat loads. While the demonstrated uncertainties in the absolute values in the heat flux sensors are high, the values and the trends match well with other calculation methods. The results of SHIIVER allow for the use of heat flux sensors for measurements of insulation performance and dynamic system thermal response for future applications.

Cryogenic Fluid Management↗

Hover and Forward Flight Performance Modeling of the Ingenuity Mars Helicopter

In 2015, NASA’s Jet Propulsion Laboratory partnered with Ames Research Center, Langley Research Center, and AeroVironment to develop Ingenuity, a small coaxial helicopter capable of flying within Mars’ unique atmospheric conditions. Ingenuity was successfully deployed from its protective shroud on the underside of the Mars 2020 Perseverance Rover and has flown 17 flights on Mars as of December 2021. A number of rotorcraft analysis tools were utilized, and a series of experimental tests were performed to ready Ingenuity for its launch with the Perseverance Rover in July 2020. In this paper, RotCFD, a Reynolds-averaged Navier-Stokes flow solver, is used to model Ingenuity in hover and forward flight for the purposes of validating tools to aid in the development of a future generation of Mars rotorcraft. The results from the RotCFD modeling are benchmarked against results from hover performance tests of the Ingenuity prototype in the 25-Foot Space Simulator at the Jet Propulsion Laboratory and are also compared to hover and forward flight predictions made by CAMRAD II, a well-known comprehensive rotorcraft analysis code. Surrogate performance models are trained to obtain a set of trimmed rotor settings for Ingenuity at different forward flight speeds, which are then used as inputs for the RotCFD forward flight simulations. Additionally, a study of the airframe-rotor interaction and a study of the aerodynamics of the individual airframe components of Ingenuity in forward flight are performed. Finally, to better understand performance predictions by RotCFD and CAMRAD II, a study is conducted on how sectional angles of attack in each code vary with radial station and azimuth.

Hover↗