Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SIDE EFFECTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Advanced Ceramic Membranes/Modules for Ultra Efficient Hydrogen (H2) Production/Carbon Dioxide (CO2) Capture for Coal-Based Polygeneration Plants: Fabrication, Testing, and CFD Modeling

Inorganic membrane-based systems are a promising technology for precombustion CO2 capture with simultaneous H2 production. State-of-the-art packages for high temperature and pressure service consist of multiple tube membrane bundles prepared in a "candle filter" configuration, in which the membrane tubes are open at one end and sealed at the other. This configuration is used for practical reasons, specifically the need to minimize problems due to thermal expansion mismatch between the ceramic tube bundle and the steel housing. However, the primary technical problem with the candle filter format for commercial-scale installations is the inability to purge the tube side (typically the permeate side), a feature that is crucial for high H2 recovery. In this study, the focus is to design and fabricate the first dual-end open full ceramic multiple tube membrane bundle that enables tube side (permeate) purge for gas separation applications. An additional key feature of this design is the simplified module layout, as the membrane bundles can be installed end-to-end with tube side (permeate) flow directly from one bundle to the next. This layout simplifies the membrane to housing seals and yields significant improvement in membrane packing density. Detailed focus areas in our studies include: (i) Materials development and preparation of the tube-to-tube sheet potting for the dual-ended bundle; (ii) the sealing and optimal module configuration design to minimize membrane stress upon module mounting; (iii) the demonstration, via the fabrication of CMS and Pd-alloy membranes supported on full-size, dual-ended ceramic support bundles, of the first example of a purgeable ceramic membrane and module; and (iv) development of a CFD model of the membrane module for calculation of feed flow distribution, and for use in scale-up, and capital cost estimating. The CFD model was validated using experimental data with the multi-tubular membrane system, employing He/N2 as a model gas mixture (surrogate for H2/CO2), and has been shown to be quite accurate. Employing the model, we are able to study the effects of operating pressure and temperature, feed and sweep gas flow rates, and the choice of membrane tube configuration on system performance.

20 FOSSIL-FUELED POWER PLANTS↗

Advanced Ceramic Membranes/Modules for Ultra Efficient Hydrogen (H2) Production/Carbon Dioxide (CO2) Capture for Coal-Based Polygeneration Plants: Fabrication, Testing and CFD Modeling

Inorganic membrane-based systems are a promising technology for precombustion CO2 capture with simultaneous H2 production. State-of-the-art packages for high temperature and pressure service consist of multiple tube membrane bundles prepared in a "candle filter" configuration, in which the membrane tubes are open at one end and sealed at the other. This configuration is used for practical reasons, specifically the need to minimize problems due to thermal expansion mismatch between the ceramic tube bundle and the steel housing. However, the primary technical problem with the candle filter format for commercial-scale installations is the inability to purge the tube side (typically the permeate side), a feature that is crucial for high H2 recovery. In this study, the focus is to design and fabricate the first dual-end open full ceramic multiple tube membrane bundle that enables tube side (permeate) purge for gas separation applications. An additional key feature of this design is the simplified module layout, as the membrane bundles can be installed end-to-end with tube side (permeate) flow directly from one bundle to the next. This layout simplifies the membrane to housing seals and yields significant improvement in membrane packing density. Detailed focus areas in our studies include: (i) Materials development and preparation of the tube-to-tube sheet potting for the dual-ended bundle; (ii) the sealing and optimal module configuration design to minimize membrane stress upon module mounting; (iii) the demonstration, via the fabrication of CMS and Pd-alloy membranes supported on full-size, dual-ended ceramic support bundles, of the first example of a purgeable ceramic membrane and module; and (iv) development of a CFD model of the membrane module for calculation of feed flow distribution, and for use in scale-up, and capital cost estimating. The CFD model was validated using experimental data with the multi-tubular membrane system, employing He/N2 as a model gas mixture (surrogate for H2/CO2), and has been shown to be quite accurate. Employing the model, we are able to study the effects of operating pressure and temperature, feed and sweep gas flow rates, and the choice of membrane tube configuration on system performance.

20 FOSSIL-FUELED POWER PLANTS↗

Measurement of the muon anomalous precession frequency at the Muon g − 2 Experiment at Fermilab

The anomalous magnetic moment of the muon, $a_\mu = \frac{g-2}{2}$ is the fractional deviation of the muon $g$-factor from the value of 2. It emerges as the cumulative effect of the virtual particles participating in the muon interaction with a magnetic field via quantum loop corrections. Its value encodes all the possible interactions between the virtual particles and, for this reason, represents an important test of the Standard Model (SM). In particular, any deviation from the SM theoretical evaluation could be due to new physics contributions. The new Muon $g-2$ (E989) Experiment at Fermilab is currently operating to repeat and improve the previous E821 experiment at Brookhaven National Laboratory (BNL), aiming to reduce the experimental error by a factor of 4 to the final accuracy of 140 parts per billion (ppb). On April 7th, 2021, the E989 collaboration published the first result based on the first year of data taking (Run-1), measuring $a_\mu = 0.001~165~920~40(54)$ with a precision of 460 ppb. The measured value is consistent with the BNL measurement and strengthens the long-standing tension with the data-driven SM prediction to a combined discrepancy of 4.2$\sigma$. On the theory side, however, new efforts involving lattice-QCD techniques are starting to question the current consensus on the theoretical prediction, demanding new improvements on both the experimental and theoretical sides. The E989 collaboration is now finalizing the analysis of Run-2 and Run-3 data and a new publication is expected in the first half of 2023 with a combined statistical uncertainty of 200 ppb. The anomalous magnetic moment $a_\mu$ is measured as the ratio between the muon spin anomalous precession frequency, $\omega_a$, and the average magnetic field experienced by the muons as they circulate in the storage ring. This thesis presents a precession frequency analysis of the Run-1 data and an evaluation of the related systematic uncertainties. A new positron reconstruction developed for the analysis of the subsequent data-taking periods, aiming to reduce some of the major systematic uncertainties of the $\omega_a$ measurement, is presented. The author's involvement in the production of the Run-2/5 data and in the precise calibration of the detectors is discussed. Finally, the complete Run-1 $a_\mu$ result is presented.

43 PARTICLE ACCELERATORS↗

Gas Transfer Across Air‐Water Interfaces in Inland Waters: From Micro‐Eddies to Super‐Statistics

In inland water covering lakes, reservoirs, and ponds, the gas exchange of slightly soluble gases such as carbon dioxide, dimethyl sulfide, methane, or oxygen across a clean and nearly flat air‐water interface is routinely described using a water‐side mean gas transfer velocity $\overline{k_{L}}$, where overline indicates time or ensemble averaging. The micro‐eddy surface renewal model predicts $\overline{k_{L}}$ = α o Sc -1/2 ($v\bar{ϵ}$) 1/4 , where Sc is the molecular Schmidt number, $v$ is the water kinematic viscosity, and $\bar{ϵ}$ is the waterside mean turbulent kinetic energy dissipation rate at or near the interface. While α o = 0.39 - 0.46 has been reported across a number of data sets, others report large scatter or variability around this value range. It is shown here that this scatter can be partly explained by high temporal variability in instantaneous ϵ around $\bar{ϵ}$, a mechanism that was not previously considered. As the coefficient of variation (CV e ) in ϵ increases, α o must be adjusted by a multiplier (1 = CV e 2 ) -3/32 that was derived from a log‐normal model for the probability density function of ϵ. Reported variations in α o with a macro‐scale Reynolds number can also be partly attributed to intermittency effects in ϵ. Such intermittency is characterized by the long‐range (i.e., power‐law decay) spatial auto‐correlation function of ϵ. That α o varies with a macro‐scale Reynolds number does not necessarily violate the micro‐eddy model. Instead, it points to a coordination between the macro‐ and micro‐scales arising from the transfer of energy across scales in the energy cascade.

Batchelor scale↗

Comparative study of the effects of prenatal sevoflurane exposure at different cortical stages on forebrain development and maturation in offspring

Introduction Brain development involves several critical stages, such as proliferation, neuronal migration, axonal pathfinding, and connection formation. Sevoflurane, a γ -aminobutyric acid (GABA) receptor agonist, is widely used as an inhaled general anesthetic. However, its impact on brain development has raised increasing concerns, particularly regarding prenatal exposure. This study aims to investigate the effects of prenatal sevoflurane exposure (PSE) at different cortical stages, focusing on its impact on the migration of glutamatergic and GABAergic neurons and neuronal behavior in offspring. Methods PSE was administered at two critical prenatal stages: embryonic day (E) 12.5 and E18.5. Double in situ hybridization was used to identify the coexpression of GABA receptors in Pax6- and Mash1-positive cells in the forebrain. The radial migration of glutamatergic neurons and the tangential migration of GABAergic neurons were analyzed. Behavioral tests, including the open-field test, elevated plus-maze test, forced swim test, tail suspension test, sucrose preference test, and Morris water maze, were performed on offspring to assess anxiety-like behaviors, depression, and learning and memory impairments. Results PSE inhibits the radial migration of glutamatergic neurons and promotes the tangential migration of GABAergic neurons. Specifically, early exposure (E12.5) inhibited the expression of the Pax6–Tbr2–Tbr1 cascade and the radial migration of Tbr1 in the ventral prefrontal cortex (PFC), whereas late exposure (E18.5) inhibited this process on the dorsal side. In addition, offspring mice with PSE exhibited increased anxiety-like behaviors, rather than depression, as demonstrated by reduced time spent in the center of the open-field test and in the open arms of the elevated plus-maze test. No significant differences were observed in the forced swim test, tail suspension test, or sucrose preference test. Furthermore, learning and memory impairments were observed in the Morris water maze. Conclusion Our results indicate that PSE at E12.5 and E18.5 leads to abnormalities in the migration of glutamatergic and GABAergic neurons, affecting long-term anxiety-like behaviors and causing learning and memory impairments in offspring mice.

Wang, Tianyuan↗

Signatures of fractional quantum anomalous Hall states in twisted MoTe 2

The interplay between spontaneous symmetry breaking and topology can result in exotic quantum states of matter. A celebrated example is the quantum anomalous Hall (QAH) state, which exhibits an integer quantum Hall effect at zero magnetic field owing to intrinsic ferromagnetism. In the presence of strong electron–electron interactions, fractional QAH (FQAH) states at zero magnetic field can emerge. These states could host fractional excitations, including non-Abelian anyons—crucial building blocks for topological quantum computation9. Here we report experimental signatures of FQAH states in a twisted molybdenum ditelluride (MoTe 2 ) bilayer. Magnetic circular dichroism measurements reveal robust ferromagnetic states at fractionally hole-filled moiré minibands. Using trion photoluminescence as a sensor, we obtain a Landau fan diagram showing linear shifts in carrier densities corresponding to filling factor v = −2/3 and v = −3/5 ferromagnetic states with applied magnetic field. These shifts match the Streda formula dispersion of FQAH states with fractionally quantized Hall conductance of ${\sigma }_{xy}=-\,\frac{2}{3}\frac{{e}^{2}}{h}$ and ${\sigma }_{xy}=-\,\frac{3}{5}\frac{{e}^{2}}{h}$ , respectively. Moreover, the v = −1 state exhibits a dispersion corresponding to Chern number −1, consistent with the predicted QAH state. In comparison, several non-ferromagnetic states on the electron-doping side do not disperse, that is, they are trivial correlated insulators. The observed topological states can be electrically driven into topologically trivial states. Our findings provide evidence of the long-sought FQAH states, demonstrating MoTe 2 moiré superlattices as a platform for exploring fractional excitations.

Quantum Hall↗

Testing unified theories for ozone response in C 4 species

Abstract There is tremendous interspecific variability in O 3 sensitivity among C 3 species, but variation among C 4 species has been less clearly documented. It is also unclear whether stomatal conductance and leaf structure such as leaf mass per area (LMA) determine the variation in sensitivity to O 3 across species. In this study, we investigated leaf morphological, chemical, and photosynthetic responses of 22 genotypes of four C 4 bioenergy species (switchgrass, sorghum, maize, and miscanthus) to elevated O 3 in side‐by‐side field experiments using free‐air O 3 concentration enrichment (FACE). The C 4 species varied largely in leaf morphology, physiology, and nutrient composition. Elevated O 3 did not alter leaf morphology, nutrient content, stomatal conductance, chlorophyll fluorescence, and respiration in most genotypes but reduced net CO 2 assimilation in maize and photosynthetic capacity in sorghum and maize. Species with lower LMA and higher stomatal conductance tended to show greater losses in photosynthetic rate and capacity in elevated O 3 compared with species with higher LMA and lower stomatal conductance. Stomatal conductance was the strongest determinant of leaf photosynthetic rate and capacity. The response of both area‐ and mass‐based leaf photosynthetic rate and capacity to elevated O 3 were not affected by LMA directly but negatively influenced by LMA indirectly through stomatal conductance. These results demonstrate that there is significant variation in O 3 sensitivity among C 4 species with maize and sorghum showing greater sensitivity of photosynthesis to O 3 than switchgrass and miscanthus. Interspecific variation in O 3 sensitivity was determined by direct effects of stomatal conductance and indirect effects of LMA. This is the first study to provide a test of unifying theories explaining variation in O 3 sensitivity in C 4 bioenergy grasses. These findings advance understanding of O 3 tolerance in C 4 grasses and could aid in optimal placement of diverse C 4 bioenergy feedstock across a polluted landscape.

54 ENVIRONMENTAL SCIENCES↗

CFD-Guided Evaluation of Spark-Assisted Gasoline Compression Ignition for Cold Idle Operation

A closed-cycle, three-dimensional (3D) computational fluid dynamics (CFD) analysis campaign was conducted to evaluate the performance of using spark plugs to assist gasoline compression ignition (GCI) combustion during cold idle operations. A conventional spark plug using single-sided J-strap design was put at a location on the cylinder head to facilitate spray-guided spark assistance. Ignition was modeled with an L-type energy distribution to depict the breakdown and the arc-to-glow phases during the energy discharge process. Several key design parameters were investigated, including injector clocking, number of nozzle holes, spray inclusion angle, number of fuel injections, fuel split ratio, and fuel injection timings. The study emphasized the region around the spark gap, focusing on flame kernel formation and development and local equivalence ratio distribution. Flame kernel development and the ignition process were found to correlate strongly with the fuel stratification and the flow velocity near the spark gap. The analysis results showed that the flame kernel development followed the direction of the local flow field. In addition, the local fuel stratification notably influenced early-stage flame kernel development due to varying injection spray patterns and the fuel injection strategies. Among these design parameters, the number of nozzle holes and fuel injection timing had the most significant effects on the engine combustion performance.

42 ENGINEERING↗

Ion diffusion coefficients in poly(3-alkylthiophenes) for energy conversion and biosensing: role of side-chain length and microstructure

Conductive polymers are promising materials as active elements for energy storage and conversion devices due to mixed ion–electron conduction. The ion diffusion coefficient is a relative measure of the efficacy of ion transport, allowing for comparison between materials and electrochemical conditions. In this work, diffusion coefficients of hexafluorophosphate (PF6–) counterions in poly(3-alkylthiophene) (P3AT) materials are measured as a function of both side-chain length and microstructure using electrochemical impedance spectroscopy (EIS). For semi-crystalline films, the diffusion coefficient is found to be anomalous and nearly independent of applied electrochemical potential. Here, the anomalous behavior of diffusion indicates that spin casting yields compact films with an enthalpic barrier to ion transport, attributed to ionic trapping. Diffusion coefficient values ~10 –11 cm 2 s –1 were measured for all films, indicating interchain spacing, in the absence of strong intermolecular interactions with the electrolyte, is not a viable design strategy to control ion transport. For the prototypical system of poly(3-hexylthiophene), we observe almost no potential dependence in ion transport for regioregular and regiorandom films of comparable molecular weight, with both exhibiting anomalous diffusion. Alternatively, changing the microstructure of poly(3-hexylthiophene) to a mostly amorphous, ion-imprinted structure yields ~500× increase in the diffusion coefficient to ~2 × 10 –8 cm 2 s –1 at 0.8 V vs. Ag/Ag + with behavior closer to ordinary diffusion. Collectively, these results indicate new insight into ion transport in conductive polymers, where ionic trapping effects can be mitigated through electrodeposition protocols over post-synthesis processing (i.e. spin coating).

14 SOLAR ENERGY↗

Modeling Advanced Strippers for CO2 Capture from Gas-Fired Power Plants using Aqueous Piperazine

Energy performance of 5 m piperazine was evaluated with an advanced stripper at the pilot scale, accounting for heat loss. Modeling studies indicated that heat loss at locations other than the heat source impacted the heat duty. For strippers with excess packing, the column was the most important source of heat loss, and values as low as 0.03 GJ/hr can cause pinch and reabsorption of CO2. Solvents like 5 m PZ are more affected by heat loss in the column due to a top-side temperature pinch at high lean loading. Heat loss impacts NGCC CO2 capture more than coal-based CO2 capture. Surface temperature measurements pilot plants showed that heat loss was 50-75% controlled by natural convection. Measured heat loss was correlated with steam flowrate and wind speed and ranged from 8126 to 219668 Btu/hr, representing 35% of the measured heat rate on average. Net heat duty linearly varied with CO2 removal at low lean loading and was similar for coal and NGCC conditions at fixed removal. At 90% removal, net heat duty was about 2.5 GJ/t with 4 and 12% CO2 in the flue gas. 7 At NGCC conditions, strippers with finite packing can benefit from a flashing feed to the top of the column by using a hot bypass. A flashing feed was linked to a reduction in irreversibility of the stripper from temperature driving forces. It also reduces heat duty by up to 6% at fixed packing height and reduces packing requirement for a fixed steam heater size compared to a warm bypass. Lean loading and lean solvent rate were effective handles to maximize profitability of a fixed stripper design at low gas price. High ambient temperature operation can benefit from low pressure stripping to about 0.18 lean loading at 150 ℃ to maintain the cyclic capacity at reduced rich loading. At low gas price, the capture plant was able to maximize profitability even with a high heat duty of 2.7-3.1 GJ/t at a lean loading of 0.2-0.22 mol/mol. Heat recovery by partial water vapor condensation in a gas-liquid exchanger can be replaced by a direct contact condenser (DCC). The DCC improved gas cooling and reduced heat duty compared to the CO2 exchanger at 0.2 lean loading. The DCC when used with a 150 ℃/5.5 bar stripper can reduce the cost of capture compared to the base case by $3- 4/tonne at 15 ft of packing (optimum) but increases cost of capture by $6/tonne with a 120 ℃/2 bar stripper and 10 ft of packing (optimum). The DCC can work effectively with a solvent with a high heat of absorption and thermal stability.

Suresh Babu, Athreya↗

Validation of SOLPS-ITER and EDGE2D-EIRENE simulations for H, D, and T JET ITER-like wall low-confinement mode plasmas

Both experiments and simulations with SOLPS-ITER and EDGE2D-EIRENE show that the onset of detachment for the low-field side (LFS) divertor – defined here as the line-averaged upstream density (〈n e 〉 edge ) at which the plasma flux to the LFS target (I LFS-plate ) starts to decrease with increasing 〈n e 〉 edge – is independent of the isotope mass. However, there are three major simulation-experiment discrepancies: (i) the absolute values of I LFS-plate and the electron density (n e ) in the LFS divertor at the onset of detachment are significantly lower in simulations, i.e., approximately a factor of 2 for I LFS-plate and a factor of 3-4 for n e ; (ii) the degree of detachment – defined here as the difference between I LFS-plate at the onset of detachment and at an 〈n e 〉 edge value close to the density limit – is smaller in simulations compared to experiments; and (iii) the experimentally observed larger degree of detachment for D and T plasmas compared to H plasmas cannot be clearly distinguished from the simulation results. There are strong indications that discrepancy (i) is to a large extent caused by neglecting Lyman-opacity effects in our simulations. The simulations predict a similar net volumetric recombination source for all isotopes due to the fact that molecule-activated recombination (MAR) compensates for the reduced electron–ion recombination (EIR) for H, whereas MAR is negligible for D and T. This similar net volumetric recombination source for all isotopes leads to an isotope-independent degree of detachment in simulations. An analysis of the Balmer-α and Balmer-$γ$ emission confirms the underestimate of MAR in simulations (especially for D and T) for the JET metallic wall, which was previously observed for devices with a carbon wall. The underestimate of MAR is an important cause for discrepancy (ii) and the fact that there is a stronger underestimate of MAR for D and T than for H explains discrepancy (iii). Extending the plasma grid to the vessel wall increases I LFS-plate and n e at the onset of detachment by 25%, and the EIR source increases by 80% in detached conditions. Hence, while the extended grid results are closer to the experimental observations, the previously described qualitative discrepancies still persist.

Balmer emission↗

Assess The Water Resistance And Thermal Performance Of Pre-flashing Methods When Adding Continuous Insulation During Re-siding (AIRS)

Retrofitting existing buildings by adding continuous insulation during re-siding projects has become a popular method for enhancing energy efficiency, especially given the aging building stock and stricter energy codes. When properly integrated with existing window systems, continuous insulation can significantly improve thermal performance, but it also presents challenges related to water resistance and building envelope integrity. Research indicates that the interface between windows and wall assemblies is critical as improper installation or sealing can lead to water intrusion, materials deterioration, and energy loss. Moreover, studies show that fully integrating the windows with the insulation layer can reduce window heat loss by up to 40%, emphasizing the importance of optimizing window placement and sealing during retrofitting to ensure both energy efficiency and structural performance. In this study, we conducted experimental tests to evaluate the water penetration and thermal performance of two window types: an aluminum window with a 2-inch installation fin and a wood window, representing typical mid-20th century designs. Using the Heat, Air, and Humidity (HAM) chamber at Oak Ridge National Laboratory (ORNL), we assessed bulk water penetration and performed COMSOL analysis for thermal flux and examined the effectiveness of different pre-flashing methods, i.e., standard self-adhered flashing tape and high-performance flashing tape with low-expansion foam, to enhance water resistance. The results indicate that applying proper flashing techniques and moisture management strategies can mitigate these risks, improving the overall performance and durability of retrofitted buildings. Additionally, proper sealing during retrofitting is essential, as improper installation can lead to moisture issues that compromise both energy efficiency and structural integrity.

Shen, Zhenglai [ORNL]↗

TRANSENSOR: Transformer Real-time Assessment INtelligent System with Embedded Network of Sensors and Optical Readout. Final Report

Utilities across the world are wrestling with evolving market dynamics, population growth and climate change. Distributed Energy Resources (DERs) such as solar photovoltaics, distributed generators and energy storage systems are becoming important parts of the U.S. energy mix. These factors are driving an increasing need for low-cost grid asset monitoring. Aside from being costly, traditional utility monitoring systems are not sufficiently robust and do not provide real-time visibility into the condition of grid assets such as transformers. Lack of accurate real-time measurements on performance has resulted in the use of lagging indicators, such as oil sample analysis. To address this need, an innovative embedded optical sensing technology, Transformer Real-time Assessment Intelligent System (TRANSENSOR) was developed, validated and demonstrated in this project. To date, TRANSENSOR has focused on transformers but is extendable to other grid assets. In addition to the technology being embedded into new transformers during manufacturing, a retrofit configuration that can be installed on existing transformers in the field was also developed. It is anticipated that the ability to retrofit existing transformers will help accelerate adoption of the underlying TRANSENSOR technology. Phase 1 of the project focused on laboratory development and qualification of the technology. Following iterations and exploration of relevant optical sensing modalities and multiplexed configurations of interest for the transformer environment, an effective candidate configuration was agreed upon, down-selected and custom-designed for embedding into General Electric (GE) network transformers. Two new GE 500 kilovolt ampere (kVA), 27 kilovolt (kV) distribution network transformers were built with embedded fiber-optic (FO) sensors and successfully qualified per industry standards at GE’s Shreveport, Louisiana facility during Phase 1 of the project. Following the successful completion of Phase 1, the team proceeded to Phase 2, which focused on a field demonstration of the technology. Over Phase 2, the first new GE transformer built with embedded fiber-optic sensors was installed in an above-ground cage and connected to the grid at Con Edison’s Astoria facility. A second transformer equipped with TRANSENSOR was installed in an underground vault. Additionally, an older (1982 year model) GE transformer in an above-ground cage was retrofitted with fiber- optic sensors and reconnected to the grid at ConEd’s facility. Analysis of data acquired from the sensors showed interesting correlations with transformer loading. Additionally, key events such as transformer low-voltage network connection, primary-side energizing, and a pressure loss event from an oil sampling were detected by the TRANSENSOR system. Online data processing/feature extraction algorithms for the second transformer in the underground vault detected key features and event alerts that were transmitted through a wireless 4G connection. The remote deployment concept showed promising results with data collection running for a total of 8 months across the three (3) GE transformers instrumented for the Phase 2 field demonstration. This sets the stage well for further development and commercialization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effects of short-term over-discharge cycling on the performance of commercial 21,700 lithium-ion cells and the identification of degradation modes

In this paper, short-term over-discharge cycling was performed on commercially available 21,700 lithium-ion cells to investigate its effects on cell performance; the degradation modes were also identified and analyzed in detail using both in-situ and ex-situ methods. Results show that observable capacity loss occurs when the cell is over-discharged to 112.5% depth of discharge. Moreover, the negative impact of the depth of discharge on cell performance (or cell aging) is more serious than the number of cycles, and continuous over-discharge cycling will accumulate such impact. The loss of Li inventory related to the decomposition and reformation of solid electrolyte interphase film is an important cause of the irreversible capacity loss/degradation of Li-ion cells during over-discharge cycling testing. Furthermore, the dissolution of copper current collector can greatly reduce the mechanical stability of the anode, and further, the deposition of Cu, the exfoliation and the cracking of active material particles can influence the transfer of ions and lead to the loss of Li inventory and the loss of active material within Li-ion cells. Additionally, when the depth of discharge exceeds 108.3%, deposition of Cu is observed on the ceramic-covered side of separators.

25 ENERGY STORAGE↗

Deep learning uncertainty quantification for clinical text classification

Machine learning algorithms are expected to work side-by-side with humans in decision-making pipelines. Thus, the ability of classifiers to make reliable decisions is of paramount importance. Deep neural networks (DNNs) represent the state-of-the-art models to address real-world classification. Although the strength of activation in DNNs is often correlated with the network’s confidence, in-depth analyses are needed to establish whether they are well calibrated. In this paper, we demonstrate the use of DNN-based classification tools to benefit cancer registries by automating information extraction of disease at diagnosis and at surgery from electronic text pathology reports from the US National Cancer Institute (NCI) Surveillance, Epidemiology, and End Results (SEER) population-based cancer registries. In particular, we introduce multiple methods for selective classification to achieve a target level of accuracy on multiple classification tasks while minimizing the rejection amount—that is, the number of electronic pathology reports for which the model’s predictions are unreliable. We evaluate the proposed methods by comparing our approach with the current in-house deep learning-based abstaining classifier. Overall, all the proposed selective classification methods effectively allow for achieving the targeted level of accuracy or higher in a trade-off analysis aimed to minimize the rejection rate. On in-distribution validation and holdout test data, with all the proposed methods, we achieve on all tasks the required target level of accuracy with a lower rejection rate than the deep abstaining classifier (DAC). Interpreting the results for the out-of-distribution test data is more complex; nevertheless, in this case as well, the rejection rate from the best among the proposed methods achieving 97% accuracy or higher is lower than the rejection rate based on the DAC. We show that although both approaches can flag those samples that should be manually reviewed and labeled by human annotators, the newly proposed methods retain a larger fraction and do so without retraining—thus offering a reduced computational cost compared with the in-house deep learning-based abstaining classifier.

59 BASIC BIOLOGICAL SCIENCES↗

Welding of Haynes 282 to Steels to Enable Modular Rotors for Advanced Ultra Super-Critical Steam Turbines

Steam turbines for an Advanced Ultra Super Critical (AUSC) fossil fired power plant will operate at temperatures well above those of current commercial steam cycles with inlet temperatures more than 760 C , which is beyond the capabilities of alloy steels presently used for steam turbine applications and requires advanced materials. Large components such as steam turbine rotors may be made of nickel based super alloys such as Haynes 282 (H282). However, monolithic forgings of superalloys in the sizes required for large steam turbines rotors can be prohibitively expensive besides many technical challenges. To minimize cost and alleviate the related technical challenges, superalloy use needs to be limited to locations on the steam turbine rotor where strength and temperature requirements cannot be met by conventional steels. This is possible if nickel-based superalloys can be successfully welded to steels and the related technical challenges - machining parts made of dissimilar welded materials, non-destructive examination of such welds for flaw detection; and, material properties of such hybrid components – are sufficiently addressed. In this technology development project, we successfully welded H282 to plates up to ~ 75 mm (~ 3 inches) to a 3.5NiCrMoV steel of similar thickness. Advanced ultrasonic inspection technique called Phased Array Ultrasonic Testing (PAUT) was employed to examine the dissimilar H282-Steel welds, into which flat bottomed side drilled holes (SDH) of various diameters were introduced, to determine the minimum detectable feature sizes; it was shown that with PAUT SDH of dia. down to 0.5 mm could be detected in the base alloys and SDH with dia. down to 2.4 mm could be detected in the weld metal under multiple orientations successfully. An autonomous machining process monitoring system was developed and demonstrated whereby the forces acting on the cutting tool could be actively monitored as the cutting tool transitioned from H282 to Steel across the weld using which the machining parameters can be potentially altered without interruption to extend tool life. This project successfully achieved its objectives of - i. Developing a welding methodology and viable welding geometries, to successfully join H282 to steel 3.5CrMoNiV steel to enable manufacture of modular steam turbine rotors for AUSC applications (conditions of at least 760 °Celsius and 3,100 psia (pounds per square inch absolute pressure) and evaluate the material properties of the welded specimen. ii. Employ the advanced ultrasonic inspection technique to the dissimilar weld metal joint and determine the minimum detectable feature sizes. iii. Develop effective machining techniques to machine such hybrid structures with online tool force monitoring and effect machine state metrics for optimal results.

20 FOSSIL-FUELED POWER PLANTS↗

The Future Electron-Ion Collider

Generalized Parton Distributions include rich information and became a powerful tool for studying hadron structure. Deeply Virtual Compton Scattering is the golden channel to access GPDs. The development of high luminosity and high-acceptance detectors (Electron-Ion Collider) allows physicists to overcome the difficulty of DVCS measurements. The outstanding performance of the accelerator performs the eA collisions at the center of mass energy from 20 to 140 GeV, while the luminosity at the scale of 1034 cm?2s?1. The new type of high-density crystal, PWO-II, produced by CRYTUR in 2×2×20 cm3 will be utilized in the calorimeter. The transparency of PWO-II crystals is > 70% at 620 nm, > 60% at 420 nm, and >35% at 360 nm. The crystals also show good radiation hardness under 30 Gy radiation exposure. Ten PWO-II crystals have a uniform light yield at 30 p.e./MeV, providing sufficient light yield to reduce the fluctuation of the energy measurements. Near 3000 crystals were constructed inside the 12-sided polygon supporting structure in the simulation. The island clustering algorithm was used for reconstructed the energy. The energy resolution study by the particle gun shows the stochastic term and constant term are 1.8% and 1.2%, respectively. The spatial resolution of NEEMC varies from 5% to 15% of the crystal?s width depending on the particle?s incident angle. The pion rejection of NEEMC can reach 103 with electron efficiency > 85% when the particle?s energy is larger than 1GeV. The Pi0- identified efficiency study can be interpreted as finding the local maxima in the single cluster caused by two high energy close photons. The study results show that efficiency is nearly 100% for pi0 energy is smaller than 10 GeV, and efficiency drops to 30% with 20 GeV pi0. The new type of 3x3 pixelated AC-LGAD were wire bonded to ALTIROC for performance test. The cross-talk between the adjacent channels is about 20% for VPA and 10% for TZ. A series of the TDC characteristic measurements show that the jitter for both preamplifiers is about 20 ps, and the time-walk effect is mild for inject charge > 12 pF. Furthermore, the beta source radiation results quantify the sharing scale of the 3x3 pixels AC-LGAD (? 20%). The electronics simulation study results show no significant changes in the spatial resolution, whether ADC resolution is 8, 10, or 12 bits. The 8-bit ADC is decided to use in the EICROC as it has a smaller size and power consumption than the 10-bit and 12-bit ADC. The ECCE is one of the full detector proposals for EIC. The new type of DVCS generator, called TOPEG, is used to generate the high acceptance beam configurations of 18×110 GeV2 electron and 4He. The acceptance study shows a -1.8 < ? < -1.4 gap between the BEMC and EEMC. The 10?x,y geometry cut is applied on the Roman Pots, so the acceptance of Roman Pots quickly drops to 0% when the polar angle of the recoiled 4He < 2 mrad. This primary ECCE simulation study suggests extending the acceptance of BEMC longitudinally as the structure limits the radial size of EEMC. The acceptance of the Roman Pots is still challenging. In 2023, The overall design of ePIC was finalized by merging two full detector proposals (ECCE and ATHENA) after a series of intensive simulation studies.

Wang, Pu-Kai↗

Characterization of Orography-Influenced Riming and Secondary Ice Production and Their Effects on Precipitation Rates Using Radar Polarimetry and Doppler Spectra (CORSIPP-SAIL)

The Characterization of Orography-Influenced Riming and Secondary Ice Production and Their Effects on Precipitation Rates Using Radar Polarimetry and Doppler Spectra (CORSIPP) project was conducted to help improve the understanding of precipitation formation in orographically influenced terrain. Special focus is put on the two processes of riming and secondary ice production and their external drivers. Two instruments, a polarimetric W-band simultaneous transmission simultaneous reception (STSR) Doppler cloud radar manufactured by Radiometer Physics GmbH (RPG, instrument type RPG-FMCW-94-DP), from now on named LIMRAD94, and the video in situ snowfall sensor (VISSS), were deployed at the U. S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Surface Atmosphere Integrated Field Laboratory (SAIL) site in Gothic, Colorado between November 2022 and June 2023 during the second SAIL winter. Note that the exact dates of data availability differ between the instruments. Both instruments arrived at Gothic on November 2, 2022, 09:20 local time. VISSS, described by Maahn et al., is equipped with two camera systems with telecentric lenses. The two cameras are at a 90° angle to each other. This configuration allows for size-independent measurements by capturing images of hydrometeors from two sides at a high frame rate of 250 Hz. With a minimum detection size of 200 μm, VISSS provides valuable insights into particle size, number, shape, complexity, and fall velocity. The VISSS was deployed on the grassland next to the ARM facility with the amazing help of the ARM employees on site. The setup started on November 2, 2022, and was finished on November 5, 2022, without major problems. VISSS measurements were started on November 6, 2022. LIMRAD94 was installed on a scaffolding platform near Orehouse (Gothic) on November 9, 2022, with the great help of RMBL staff. LIMRAD94 was mounted on a cold temperature scanner prototype. After a short test of the setup on November 9, 2022, the digital control of the scanner elevation stopped working for (at that time) unknown reasons. All attempts to resolve the problem failed. This malfunction made it impossible to operate LIMRAD94 in scanning mode. The scanner was then manually moved to zenith pointing mode and between November 10 and November 15, 2022, vertical observations for polarimetric calibration were performed. On November 15, 2022, after the polarimetric calibration was applied, the scanner was manually moved to 40° elevation with azimuthal view towards the Ka-band ARM Zenith Radar (KAZR) and measurements were continued at constant elevation. Investigation of the scanner malfunction on February 6, 2023, by Benn Schmatz revealed a disengagement between the cogwheel of the elevation motor and the cogwheel moving the scanner in elevation. This mechanical issue was temporarily solved by re-engaging the cogwheels. This made the scanner operational again for about four weeks, until mechanical force disengaged the cogwheels again on March 15, 2023. This repeated scanner failure remained undetected for about three weeks until April 8, 2023; during this time the scanner was stuck at 72° elevation. However, the radar software continued to produce data files falsely indicating that the scanner was still operational. After the scanner failure was noticed, scanning was stopped again, and we returned to constant elevation measurements. On May 15, 2023, the cogwheels of the elevation motor were secured with additional screws sent by the manufacturer. At some point in May, the cogwheels of the azimuth motor were also disengaged by mechanical force, which still allowed for range height indicator (RHI) but no plan position indicator (PPI) scans in the last weeks of the campaign. The azimuth motor was repaired in Germany after the end of the campaign. Throughout the campaign, RMBL and ARM staff kept the radar and the VISSS free of snow.

54 ENVIRONMENTAL SCIENCES↗