At least 1,153 records · Page 64

Correlations of Apparent Cellulose Crystallinity Determined by XRD, NMR, IR, Raman, and SFG Methods

Although the cellulose crystallinity index (CI) is used widely, its limitations have not been adequately described. In this study, the CI values of a set of reference samples were determined from X-ray diffraction (XRD), nuclear magnetic resonance (NMR), and infrared (IR), Raman, and vibrational sum frequency generation (SFG) spectroscopies. The intensities of certain crystalline peaks in IR, Raman, and SFG spectra positively correlated with the amount of crystalline cellulose in the sample, but the correlation with XRD was nonlinear as a result of fundamental differences in detection sensitivity to crystalline cellulose and improper baseline corrections for amorphous contributions. It is demonstrated that the intensity and shape of the XRD signal is affected by both the amount of crystalline cellulose and crystal size, which makes XRD analysis complicated. It is clear that the methods investigated show the same qualitative trends for samples, but the absolute CI values differ depending on the determination method. This clearly indicates that the CI, as estimated by different methods, is not an absolute value and that for a given set of samples the CI values can be compared only as a qualitative measure.

09 BIOMASS FUELS↗

Structural and Magnetic Studies of Nano-crystalline Ferrites MFe{sub 2}O{sub 4} (M = Zn, Ni, Cu, and Co) Synthesized Via Citrate Gel Autocombustion Method

Nano-crystalline ferrites with the chemical formula MFe{sub 2}O{sub 4} (M = Zn, Ni, Cu, and Co) were synthesized via autocombustion route with citric acid as fuel. The ratio of citric acid to metal nitrate was taken as 1:1. The synthesized samples were characterized by powder X-ray diffraction and far-IR spectroscopy. The measured lattice constants and observed characteristic IR absorption bands of all samples were in good agreement with the reported values and showed the formation of a cubic spinel structure. The crystallite sizes of all samples were determined using high-intensity peaks and a W-H plot. The crystallite sizes of all samples were observed to be in the range of 16–26 nm with the least crystallite size of 16.8 nm for copper ferrite. All structural parameters were calculated using an experimental lattice constant and an oxygen positional parameter and correlated with far-IR results. Zinc and copper owing to their large cation radii showed the expansion of the lattice in view of the oxygen positional parameter. Magnetic measurements were carried out using a vibrating sample magnetometer at room temperature, and parameters such as saturation magnetization, coercivity, remanence, squareness ratio, and Bohr magnetons were calculated. Among all synthesized nano-ferrites, cobalt nano-ferrite showed the highest saturation magnetization of 41 emu/g, whereas zinc ferrite displayed a low saturation magnetization value of 12.87 emu/g.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spatial and temporal evolution of ion energies in high power impulse magnetron sputtering plasma discharge

High power impulse magnetron sputtering (HIPIMS) is a novel deposition technology successfully implemented on full scale industrial machines. HIPIMS utilizes short pulses of high power delivered to the target in order to generate high amount of metal ions. The life-span of ions between the pulses and their energy distribution could strongly influence the properties and characteristics of the deposited coating. In modern industrial coating machines the sample rotates on a substrate holder and changes its position and distance with regard to the magnetron. Time resolved measurements of the ion energy distribution function (IEDF) at different distances from the magnetron have been performed to investigate the temporal evolution of ions at various distances from target. The measurements were performed using two pressures, 1 and 3 Pa to investigate the influence of working gas pressure on IEDF. Plasma sampling energy-resolved mass spectroscopy was used to measure the IEDF of Ti{sup 1+}, Ti{sup 2+}, Ar{sup 1+}, and Ar{sup 2+} ions in HIPIMS plasma discharge with titanium (Ti) target in Ar atmosphere. The measurements were done over a full pulse period and the distance between the magnetron and the orifice of the mass spectrometer was changed from 25 to 215 mm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Resolution Performance of HERA-B Lead-Glass Calorimeters

In preparation of upcoming 12GeV experiments at Thomas Jefferson National Accelerator Facility it is necessary to upgrade existing systems or install new detectors. As part of this effort, an array of lead-glass sampling calorimeters is need for use in the GEP-5 experiment. A sampling calorimeter can be used to determine the energy and spatial position of a high energy particle that enters it while simultaneously stopping the particle. To determine the appropriate construction to meet the needs of upcoming experiments, it was necessary to take an existing model and confirm its energy and position resolution. This model could then be confirmed as an option for the final construction, or used as a starting point to design a better detector. For our test we obtained ten lead-glass calorimeters used in HERA-B and tested them in End Station A at SLAC. I will report on our findings for the HERA-B lead-glass sampling calorimeters. I will cover the results of both the energy and position resolutions as well as the methods used to determine these quantities.

Losada, Anthony↗

Precision lattice parameter determination from transmission diffraction of thick specimens with irregular cross sections

Accurate determination of lattice parameters from X-ray diffraction requires that the diffraction angles be measured very precisely, and significant errors result if the sample–detector separation differs from that assumed. Transmission diffraction from bones, which have a complex cross section and must be left intact, is a situation where this separation is difficult to measure and it may differ from position to position across the specimen. Here, this article describes a method for eliminating the effect of variable sample cross section. Diffraction patterns for each position on the specimen are collected before and after 180° rotation about an axis normal to the cross section of interest. This places the centroid of the diffracting mass at the center of rotation and provides the absolute lattice parameters from the average apparent lattice parameters at the two rotation angles. Diffraction patterns were collected across the cross section of three specimens: a 3D-printed elliptical cylinder of Hyperelastic Bone (HB), which is composed primarily of synthetic hydroxyapatite (hAp), a 3D-printed HB model of the second metacarpal bone (Mc2), and a modern human Mc2 containing nanocrystalline carbonated apatite (cAp). Rietveld refinement was used to determine precise unit-cell parameters a apparent and c apparent for each pattern of each scan, and these values determined the actual average < a > and < c > for each sample. In conclusion, the results indicate that the 0°/180° rotation method works well enough to uncover variations approaching 1 × 10 -3 Å in cAp unit-cell parameters in intact bones with irregular cross sections.

36 MATERIALS SCIENCE↗

Apparatus and method for generating a magnetic field by rotation of a charge holding object

A device and a method for the production of a magnetic field using a Charge Holding Object that is mechanically rotated. In a preferred embodiment, a Charge Holding Object surrounding a sample rotates and subjects the sample to one or more magnetic fields. The one or more magnetic fields are used by NMR Electronics connected to an NMR Conductor positioned within the Charge Holding Object to perform NMR analysis of the sample.

47 OTHER INSTRUMENTATION↗

Low vibration high numerical aperture automated variable temperature Raman microscope

Raman micro-spectroscopy is well suited for studying a variety of properties and has been applied to wide- ranging areas. Combined with tuneable temperature, Raman spectra can offer even more insights into the properties of materials. However, previous designs of variable temperature Raman microscopes have made it extremely challenging to measure samples with low signal levels due to thermal and positional instability as well as low collection efficiencies. Thus, contemporary Raman microscope has found limited applicability to probing the subtle physics involved in phase transitions and hysteresis. This paper describes a new design of a closed-cycle, Raman microscope with full polarization rotation. High collection efficiency, thermal and mechanical stability are ensured by both deliberate optical, cryogenic, and mechanical design. Measurements on two samples, Bi 2 Se 3 and V 2 O 3 , which are known as challenging due to low thermal conductivities, low signal levels and/or hysteretic effects, are measured with previously undemonstrated temperature resolution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Load partitioning between ferrite/martensite and dispersed nanoparticles of a 9Cr ferritic/martensitic (F/M) ODS steel at high temperatures

In this study, a high-energy synchrotron radiation X-ray technique was used to investigate the tensile deformation processes of a 9Cr-ODS ferritic/martensitic (F/M) steel at different temperatures. Two minor phases within the 9Cr-ODS F/M steel matrix were identified as Y2Ti2O7 and TiN by the high-energy X-ray diffraction, and confirmed by the analysis using energy dispersive X-ray spectroscopy (EDS) of scanning transmission electron microscope (STEM). The lattice strains of the matrix and particles were measured through the entire tensile deformation process. During the tensile tests, the lattice strains of the ferrite/martensite and the particles (TiN and Y2Ti2O7) showed a strong temperature dependence, decreasing with increasing temperature. Analysis of the internal stress at three temperatures showed that the load partitioning between the ferrite/martensite and the particles (TiN and Y2Ti2O7) was initiated during sample yielding and reached to a peak during sample necking. At three studied temperatures, the internal stress of minor phases (Y2Ti2O7 and TiN) was about 2 times that of F/M matrix at yielding position, while the internal stress of Y2Ti2O7 and TiN reached about 4.5-6 times and 3-3.5 times that of the F/M matrix at necking position, respectively. It indicates that the strengthening of the matrix is due to minor phases (Y2Ti2O7 and TiN), especially Y2Ti2O7 particles. Although the internal stresses of all phases decreased with increasing temperature from RT to 600 degrees C, the ratio of internal stresses of each phase at necking position stayed in a stable range (internal stresses of Y2Ti2O7 and TiN were about 4.5-6 times and 3-3.5 times of that of F/M matrix, respectively). The difference between internal stress of the F/M matrix and the applied stress at 600 degrees C is slightly lower than those at RI and 300 degrees C, indicating that the nanoparticles still have good strengthening effect at 600 degrees C. (C) 2015 Elsevier B.V. All rights reserved.

Microstructure↗

Laser measuring system for incremental assemblies

Wire-wrapped frame assemblies used in spark chambers and the like can be measured using a system which utilizes a laser, an interferometer, and a retroreflector to precisely measure distance. A light source and a photodetector are located adjacent the incremental assembly and mounted on a movable carriage. The interferometer is also mounted on the movable carriage, while the laser and retroreflector are positioned at either end of the carriage track. The carriage is moved along one edge of the incremental assembly between the retroreflector and the laser, and as the carriage is moved, the light from the light source to the photodetector is interrupted. This produces a trigger command to a control unit which in turn causes a distance measurement to be made. A printout is provided for each sampling trigger command to list such items as ideal position, actual position and amount of error.

Etzel, J. G.↗

Responses to Nonconformances, AIHA Onsite Assessment August 29-31, 2022

A nonconformance report (NCR) was not generated to document the original Beryllium (Be) positive result being changed to negative due to an oversight by the lab. The sample was re-analyzed on the Agilent ICP-OES which includes software to deal with interferences and resulted in a negative for Be. In order to determine the cause of the false positive, which was originally thought to be due to the Titanium interference in the sample, the laboratory analyzed a blank and a reporting limit standard with 5 ppm and 10 ppm of Titanium added in. These were analyzed on the Perkin Elmer ICP 5 instrument to see if the positive Be was reproducible.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mercury biomagnification and the trophic structure of the ichthyofauna from a remote lake in the Brazilian Amazon

The present study assesses mercury biomagnification and the trophic structure of the ichthyofauna from the Puruzinho Lake, Brazilian Amazon. In addition to mercury determination, the investigation comprised the calculation of Trophic Magnification Factor (TMF) and Trophic Magnification Slope (TMS), through the measurements of stable isotopes of carbon (δ{sup 13}C) and nitrogen (δ{sup 15}N) in fish samples. These assessments were executed in two different scenarios, i.e., considering (1) all fish species or (2) only the resident fish (excluding the migratory species). Bottom litter, superficial sediment and seston were the sources used for generating the trophic position (TP) data used in the calculation of the TMF. Samples from 84 fish were analysed, comprising 13 species, which were categorized into four trophic guilds: iliophagous, planktivorous, omnivorous and piscivorous fish. The δ{sup 13}C values pointed to the separation of the ichthyofauna into two groups. One group comprised iliophagous and planktivorous species, which are linked to the food chains of phytoplankton and detritus. The other group was composed by omnivorous and piscivorous fish, which are associated to the trophic webs of phytoplankton, bottom litter, detritus, periphyton, as well as to food chains of igapó (blackwater-flooded Amazonian forests). The TP values suggest that the ichthyofauna from the Puruzinho Lake is part of a short food web, with three well-characterized trophic levels. Mercury concentrations and δ{sup 13}C values point to multiple sources for Hg input and transfer. The similarity in Hg levels and TP values between piscivorous and planktivorous fish suggests a comparable efficiency for the transfer of this metal through pelagic and littoral food chains. Regarding the two abovementioned scenarios, i.e., considering (1) the entire ichthyofauna and (2) only the resident species, the TMF values were 5.25 and 4.49, as well as the TMS values were 0.21 and 0.19, respectively. These findings confirm that Hg biomagnifies through the food web of Puruzinho Lake ichthyofauna. The migratory species did not significantly change mercury biomagnification rate in Puruzinho Lake; however, they may play a relevant role in Hg transport. The biomagnification rate (TMS value) in Puruzinho Lake was higher than the average values for its latitude, being comparable to TMS values of temperate and polar systems (marine and freshwater environments). - Highlights: • Mercury biomagnified in food web of a remote Amazonian lake. • δ{sup 13}C and δ{sup 15}N values suggest multiple Hg sources in food web with 3 trophic levels. • We found similar Hg transfer efficiencies in pelagic and littoral food chains. • Migration may influence the trophic structure assessment performed with δ{sup 15}N. • The migrating species did not significantly alter the biomagnification calculation.

54 ENVIRONMENTAL SCIENCES↗

Chromatin structure predicts survival in glioma patients

The pathological changes in epigenetics and gene regulation that accompany the progression of low-grade to high-grade gliomas are under-studied. The authors use a large set of paired atac-seq and RNA-seq data from surgically resected glioma specimens to infer gene regulatory relationships in glioma. Thirty-eight glioma patient samples underwent atac-seq sequencing and 16 samples underwent additional RNA-seq analysis. Using an atac-seq/RNA-seq correlation matrix, atac-seq peaks were paired with genes based on high correlation values (|r 2 | > 0.6). Samples clustered by IDH1 status but not by grade. Surprisingly there was a trend for IDH1 mutant samples to have more peaks. The majority of peaks are positively correlated with survival and positively correlated with gene expression. Constructing a model of the top six atac-seq peaks created a highly accurate survival prediction model (r 2 = 0.68). Four of these peaks were still significant after controlling for age, grade, pathology, IDH1 status and gender. Grade II, III, and IV (primary) samples have similar transcription factors and gene modules. However, grade IV (recurrent) samples have strikingly few peaks. Patient-derived glioma cultures showed decreased peak counts following radiation indicating that this may be radiation-induced. This study supports the notion that IDH1 mutant and IDH1 wildtype gliomas have different epigenetic landscapes and that accessible chromatin sites mapped by atac-seq peaks tend to be positively correlated with expression. The data in this study leads to a new model of treatment response wherein glioma cells respond to radiation therapy by closing open regions of DNA.

59 BASIC BIOLOGICAL SCIENCES↗

Urinary levels of triclosan and triclocarban in several Asian countries, Greece and the USA: Association with oxidative stress

Highlights: • Triclosan and triclocarban were analyzed in 430 urine samples collected from 9 countries. • Triclosan concentrations as high as 1600 ng/mL were found in urine. • Age and gender related differences in triclosan levels were minimal. • TCC levels were marginally correlated with the oxidative stress marker, 8OHdG. Triclosan (TCS) and Triclocarban (TCC) are widely used as antimicrobial preservatives in personal care products (PCPs). Because of their potential for endocrine disrupting effects, human exposure to these chemicals is a concern. Biomonitoring studies of human exposure to TCS and TCC have shown widespread exposure of populations in western European countries and the USA. However, exposure to TCC and TCS by populations in Asian countries is less well known. In this study, concentrations of TCS and TCC were determined in human urine collected from seven Asian countries (China, India, Korea, Kuwait, Japan, Saudi Arabia, and Vietnam), and Greece and the USA. A total of 430 urine samples were analyzed for TCS and TCC, of which 355 (83%) and 82 (19%), respectively, contained measurable levels of these chemicals. The overall geometric mean [GM] concentrations of TCS and TCC, were 1.36 and 0.03 ng/mL, respectively. The highest mean concentration of TCS was found in urine from China (100 ng/mL) and the lowest concentration was found in urine from Vietnam (2.34 ng/mL). We also analyzed urinary 8-OHdG, a marker of oxidative stress, to elucidate the association with TCS and TCC levels for samples from Saudi Arabia (n=130) and a positive correlation between Ln-transformed TCC levels and 8-OHdG was found, although this was not statistically significant. This is the first study to report urinary levels of TCS and TCC in several Asian countries, especially for Vietnam, Kuwait, and Japan.

54 ENVIRONMENTAL SCIENCES↗

Crystal structures and microwave dielectric properties of Zn,W co-substituted BaTiO{sub 3} perovskite ceramics

Zn,W co-substituted BaTiO{sub 3} perovskite ceramics with compositions of Ba[Ti{sub 1-x}(Zn{sub 1/2}W{sub 1/2}){sub x}]O{sub 3} (x=0.40-1.00) were synthesized by the conventional solid-state reaction method and studied by X-ray diffraction and dielectric measurements. Their structures transferred from cubic (x=0.40) with space group Pm3{sup Macron }m to hexagonal (x=0.55-0.60) with P6{sub 3}/mmc, and then to cubic double pervoskite (x=1.00) with Fm3{sup Macron }m. The refinement results of sample (x=0.60) revealed that the negative and positive charge centers are not consistent with each other in the face-sharing oxygen octahedra. Compared with the cubic perovskites, the hexagonal ones had the increased quality factor (Q Multiplication-Sign f), the decreased dielectric constant ({epsilon}{sub r}), and especially the near-zero temperature coefficient of resonant frequency ({tau}{sub f}), whose absolute values were less than 5 ppm/ Degree-Sign C. The relationships between structures and properties were discussed. - Graphical abstract: The departure of the negative and positive charge centers in the face-sharing oxygen octahedra of hexagonal unit cell. Highlights: Black-Right-Pointing-Pointer A phase transition from simple cubic to hexagonal and then to cubic double pervoskite occurred. Black-Right-Pointing-Pointer Refinement results prove that spontaneous dipoles present in face-sharing oxygen octahedra. Black-Right-Pointing-Pointer Hexagonal perovskites had higher Q Multiplication-Sign f, nearer-zero {tau}{sub f}, and lower {epsilon}{sub r} than the cubic ones. Black-Right-Pointing-Pointer On the presence of the hexagonal perovskite, |{tau}{sub f}| was less than 5 ppm/ Degree-Sign C.

36 MATERIALS SCIENCE↗

Increasing the detection sensitivity of the Radionuclide Aerosol Sampler/Analyzer using a cosmic veto system

Different configurations of a cosmic veto system have been evaluated for the Radionuclide Aerosol Sampler/Analyzer (RASA). The upgrade has the potential to resolve the issue that U.S. IMS radionuclide stations have difficulty meeting the 140Ba Minimum Detectable Concentration (MDC) certification requirement when the natural background radioactivity is high. It also aims to improve the detection sensitivity of the RASA system for other fission and activation products indicative of a nuclear explosion. This proof of principal utilizes a prototype RASA system located at Pacific Northwest National Laboratory (PNNL), and has demonstrated background reductions by up to 11.3% and improvements in the average MDC by up to 7.7%. Recommendations are made for either a 1 or 3 plate configuration, which improves the 140Ba MDC by 5.6% and 7.2% for a blank filter. Whilst elevated 212Pb activity remains problematic, the cosmic veto system provides a practical solution for sensitivity improvement with little design modification of the RASA. It also has value in improving sensitivity and preventing false-positives at remote U.S. IMS station locations where sample transfer for laboratory analysis is logistically difficult.

Comprehensive Nuclear-Test-Ban Treaty, RASA, Cosmi↗

Differential gene expression profiling of human adipose stem cells differentiating into smooth muscle-like cells by TGFβ1/BMP4

Regenerative repair of the vascular system is challenging from the perspectives of translational medicine and tissue engineering. There are fundamental hurdles in front of creating bioartificial arteries, which involve recaputilation of the three-layered structure under laboratory settings. Obtaining and maintaining smooth muscle characteristics is an important limitation, as the transdifferentiated cells fail to display mature phenotype. This study aims to shed light on the smooth muscle differentiation of human adipose stem cells (hASCs). To this end, we first acquired hASCs from lipoaspirate samples. Upon characterization, the cells were induced to differentiate into smooth muscle (SM)-like cells using a variety of inducer combinations. Among all, TGFβ1/BMP4 combination had the highest differentiation efficiency, based on immunohistochemical analyses. hSM-like cell samples were compared to hASCs and to the positive control, human coronary artery-smooth muscle cells (hCA-SMCs) through gene transcription profiling. Microarray findings revealed the activation of gene groups that function in smooth muscle differentiation, signaling pathways, extracellular modeling and cell proliferation. Our results underline the effectiveness of the growth factors and suggest some potential variables for detecting the SM-like cell characteristics. Evidence in transcriptome level was used to evaluate the TGFβ1/BMP4 combination as a previously unexplored effector for the smooth muscle differentiation of adipose stem cells. - Highlights: • Human adipose stem cells (hASCs) were isolated, characterized and cultured. • Growth factor combinations were evaluated for their effectiveness in differentiation using IHC. • hASCs were differentiated into smooth muscle (SM)-like cells using TGF-β1 and BMP4 combination. • Microarray analysis was performed for hASCs, SM-like cells and coronary artery-SMCs. • Microarray data was used to perform hierarchical clustering and interpretation of activated pathways.

60 APPLIED LIFE SCIENCES↗

Spatial localization of excitons and charge carriers in hybrid perovskite thin films

The fundamental photophysics underlying the remarkably high power conversion efficiency of organic-inorganic hybrid perovskite-based solar cells has been increasingly studied using complementary spectroscopic techniques. The spatially heterogeneous polycrystalline morphology of the photoactive layers owing to the presence of distinct crystalline grains has been generally neglected in optical measurements and therefore the reported results are typically averaged over hundreds or even thousands of such grains. Here, we apply femtosecond transient absorption microscopy to spatially and temporally probe ultrafast electronic excited-state dynamics in pristine methylammonium lead tri-iodide (CH 3 NH 3 PbI 3 ) thin films and composite structures. We found that the electronic excited-state relaxation kinetics are extremely sensitive to the sample location probed, which was manifested by position-dependent decay timescales and transient signals. As a result, analysis of transient absorption kinetics acquired at distinct spatial positions enabled us to identify contributions of excitons and free charge carriers.

36 MATERIALS SCIENCE↗

Relationship between Atmospheric Aerosol Mineral Surface Area and Iron Solubility

Size-fractionated dust aerosols (>7.2, 7.2-3, 3-1.5, 1.5-0.95, 0.95-0.49, and <0.49 mu m) originating from source regions, including the Sahara, North America, and the local marine environment, were collected shipboard in the Atlantic Ocean. Iron mineralogy, oxidation state, and solubility were examined using wet chemistry and synchrotron-based iron K-edge X-ray absorption near edge structure (XANES) spectroscopy. The soluble iron concentration showed a strong positive correlation with calculated aerosol an surface area (R 2 = 0.81). The iron XANES spectra, for all size ranges, were nearly identical for Saharan samples. Spectra from North American and local atmosphere (marine) provenances exhibited more variation between size fractions, with no obvious trends with the particle size. Saharan spectra were distinct from North American spectra, which confirms the different compositions of the two sources. Marine spectra displayed a range of both North American and Saharan spectral characteristics, likely reflecting that the marine samples are ultimately derived from these and potentially other sources. However, despite the notable variation in compositions, the surface area is the predominant factor affecting total iron solubility. Aerosol iron solubilization through acidic surface reactions would be most effective in samples with the highest surface area, which likely results in the strong positive correlation with soluble iron concentration in distilled water.

58 GEOSCIENCES↗