Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Robotics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Sentinel Lymph Node Dissection to Select Clinically Node-negative Prostate Cancer Patients for Pelvic Radiation Therapy: Effect on Biochemical Recurrence and Systemic Progression

Purpose: To assess the efficacy of robotic-assisted laparoscopic sentinel lymph node (SLN) dissection (SLND) to select those patients with prostate cancer (PCa) who would benefit from additional pelvic external beam radiation therapy and long-term androgen deprivation therapy (ADT). Methods and Materials: Radioisotope-guided SLND was performed in 224 clinically node-negative patients scheduled to undergo external beam radiation therapy. Patients with histologically positive SLNs (pN1) were also offered radiation therapy to the pelvic lymph nodes, combined with 3 years of ADT. Biochemical recurrence (BCR), overall survival, and metastasis-free (including pelvic and nonregional lymph nodes) survival (MFS) rates were retrospectively calculated. The Briganti and Kattan nomogram predictions were compared with the observed pN status and BCR. Results: The median prostate-specific antigen (PSA) value was 15.4 ng/mL (interquartile range [IQR] 8-29). A total number of 834 SLNs (median 3 per patient; IQR 2-5) were removed. Nodal metastases were diagnosed in 42% of the patients, with 150 SLNs affected (median 1; IQR 1-2). The 5-year BCR-free and MFS rates for pN0 patients were 67.9% and 87.8%, respectively. The corresponding values for pN1 patients were 43% and 66.6%. The PSA level and number of removed SLNs were independent predictors of BCR and MFS, and pN status was an additional independent predictor of BCR. The 5-year overall survival rate was 97.6% and correlated only with pN status. The predictive accuracy of the Briganti nomogram was 0.665. Patients in the higher quartiles of Kattan nomogram prediction of BCR had better than expected outcomes. The complication rate from SLND was 8.9%. Conclusions: For radioisotope-guided SLND, the high staging accuracy is accompanied by low morbidity. The better than expected outcomes observed in the lower quartiles of BCR prediction suggest a role for SLN biopsy as a potential selection tool for the addition of pelvic radiation therapy and ADT intensification in pN1 patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preliminary Results of a Phase 1 Dose-Escalation Trial for Early-Stage Breast Cancer Using 5-Fraction Stereotactic Body Radiation Therapy for Partial-Breast Irradiation

Purpose: To evaluate the tolerability of a dose-escalated 5-fraction stereotactic body radiation therapy for partial-breast irradiation (S-PBI) in treating early-stage breast cancer after partial mastectomy; the primary objective was to escalate dose utilizing a robotic stereotactic radiation system treating the lumpectomy cavity without exceeding the maximum tolerated dose. Methods and Materials: Eligible patients included those with ductal carcinoma in situ or invasive nonlobular epithelial histologies and stage 0, I, or II, with tumor size <3 cm. Patients and physicians completed baseline and subsequent cosmesis outcome questionnaires. Starting dose was 30 Gy in 5 fractions and was escalated by 2.5 Gy total for each cohort to 40 Gy. Results: In all, 75 patients were enrolled, with a median age of 62 years. Median follow-up for 5 cohorts was 49.9, 42.5, 25.7, 20.3, and 13.5 months, respectively. Only 3 grade 3 toxicities were experienced. There was 1 dose-limiting toxicity in the overall cohort. Ten patients experienced palpable fat necrosis (4 of which were symptomatic). Physicians scored cosmesis as excellent or good in 95.9%, 100%, 96.7%, and 100% at baseline and 6, 12, and 24 months after S-PBI, whereas patients scored the same periods as 86.5%, 97.1%, 95.1%, and 95.3%, respectively. The disagreement rates between MDs and patients during those periods were 9.4%, 2.9%, 1.6%, and 4.7%, respectively. There have been no recurrences or distant metastases. Conclusion: Dose was escalated to the target dose of 40 Gy in 5 fractions, with the occurrence of only 1 dose-limiting toxicity. Patients felt cosmetic results improved within the first year after surgery and stereotactic body radiation therapy. Our results show minimal toxicity with excellent cosmesis; however, further follow-up is warranted in future studies. This study is the first to show the safety, tolerability, feasibility, and cosmesis results of a 5-fraction dose-escalated S-PBI treatment for early-stage breast cancer in the adjuvant setting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

How Advances in Imaging Will Affect Precision Radiation Oncology

Radiation oncology is 1 of the most structured disciplines in medicine. It is of a highly technical nature with reliance on robotic systems to deliver intervention, engagement of diverse expertise, and early adoption of digital approaches to optimize and execute the application of this highly effective cancer treatment. As a localized intervention, the dependence on sensitive, specific, and accurate imaging to define the extent of disease, its heterogeneity, and adjacency to normal tissues directly affects the therapeutic ratio. Image-based in vivo temporal monitoring of the response to treatment enables adaptation and further affects the therapeutic ratio. Thus, more precise intervention will enable fractionation schedules that better interoperate with advances such as immunotherapy. In the data set–rich era that promises precision and personalized medicine, the radiation oncology field will integrate these new data into highly protocoled pathways of care that begin with multimodality prediction and enable patient-specific adaptation of therapy based on quantitative measures of the individual's dose–volume temporal trajectory and midtherapy predictions of response. In addition to advancements in computed tomography imaging, emerging technologies, such as ultra-high-field magnetic resonance and molecular imaging will bring new information to the design of treatments. Next-generation image guided radiation therapy systems will inject high specificity and sensitivity data and stimulate adaptive replanning. In addition, a myriad of pre- and peritherapeutic markers derived from advances in molecular pathology (eg, tumor genomics), automated and comprehensive imaging analytics (eg, radiomics, tumor microenvironment), and many other emerging biomarkers (eg, circulating tumor cell assays) will need to be integrated to maximize the benefit of radiation therapy for an individual patient. We present a perspective on the promise and challenges of fully exploiting imaging data in the pursuit of personalized radiation therapy, drawing from the presentations and broader discussions at the 2016 American Society of Therapeutic Radiation Oncology–National Cancer Institute workshop on Precision Medicine in Radiation Oncology (Bethesda, MD).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Towards operational atmospheric correction of airborne hyperspectral imaging spectroscopy: Algorithm evaluation, key parameter analysis, and machine learning emulators

Atmospheric correction of airborne hyperspectral imaging spectroscopy (AHIS) to obtain high-quality surface reflectance is the prerequisite for remote sensing applications. Over the last decades, different atmospheric correction methods have been developed based on radiative transfer models (RTMs), however, the relative performances of different algorithms are unclear. Automated operational atmospheric correction methods to process large-volume AHIS data in a high-accurate and high-throughput manner are still lacking. Therefore, this study proposed an operational atmospheric correction pipeline for deriving surface reflectance from AHIS data. To ensure the accuracy and efficiency of the pipeline, we focused on three specific aspects: (1) selecting a suitable RTM for the development of atmospheric lookup tables (LUTs) by comparing the commercial MODerate resolution atmospheric TRANsmission (MODTRAN) and open-sourced Library for Radiative TRANsfer (LibRadTRAN) models, where the widely-used software, Atmospheric/Topographic Correction for Airborne Imagery (ATCOR), was used as benchmarks; (2) identifying key atmospheric correction parameters and determining suitable sources for parameter retrievals including AHIS, Moderate Resolution Imaging Spectroradiometer (MODIS), and AErosol RObotic NETwork (AERONET); and (3) testing the performance of using machine learning emulators to speed up the RTM-based atmospheric correction. Results indicate that (1) atmospheric correction based on MODTRAN LUTs can produce surface reflectance accurately with mean absolute errors < 0.05 and cosine similarities > 0.98 compared to field measurements, which is comparable to the software ATCOR and slightly outperforms the LibRadTRAN LUTs; (2) sobol global sensitivity analysis demonstrates that in the atmospheric correction, visibility and water vapor are two key parameters that can be accurately derived from AHIS in contrast to MODIS or AERONET data; and (3) Random Forest emulators can produce accurate estimations of surface reflectance with mean absolute errors < 0.03 and cosine similarities > 0.98 for higher processing efficiency and determine a suitable set of wavelengths for retrieving atmospheric visibility and water vapor. In conclusion, the proposed atmospheric correction pipeline also improved the four-stream radiative transfer theory for airborne applications by considering adjacent effects from airborne surrounding pixels and can also be applied for atmospheric correction of hyperspectral data from spaceborne missions.

47 OTHER INSTRUMENTATION↗

Optimizing Bendability and Hardness of Age-Hardenable Aluminum Sheets through Local Thermo-Mechanical Processing

This paper introduces a novel thermo-mechanical process to modify the local mechanical properties of 6xxx aluminum (Al-Mg-Si-Cu) alloy sheets. In this process, two pairs of rollers travel along the length of a sheet while locally bending and unbending it so that the final shape and thickness of the sheet remains unchanged. Room temperature bending/unbending (B/U) produces a deformation gradient through thickness and local hardening in both T4 and T6 sheets (with 41% and 18% greater Vickers hardness, respectively). High temperature bending/unbending performed at ~ 500°C via induction heating, produces significant improvements in local formability as measured by bend testing. Formability levels equivalent to the as-received T4 temper are achieved within the processed zones of T6 sheets with bend angles of ~ 150°, without disturbing the T6 temper in the remainder of the sheet. Finite element simulations and characterization explained the mechanical property improvements and the heterogenous microstructure with weakened Cube texture. Due to its similarity with the roller hemming process, and its compact dimensions, the apparatus developed for B/U has the potential for seamless integration with roller hemming robots to selectively process high strength aluminum sheet materials within mass-production settings.

Efe, Mert [BATTELLE (PACIFIC NW LAB)]↗

Magnetism and structure of Fe- and Co-substituted Mn 2 NiSn

Mn-containing Heuslers are important magnetic shape-memory alloys for fast and precise actuators in manufacturing, robotics, surgery, and other applications. Among the key requirements are a high magnetization and favorable thermal properties, especially a high Curie temperature. In this work, the effect of Fe and Co substitution on the structure and magnetism of Mn 2 NiSn alloys is investigated. The Heusler alloys have been produced by melt spinning and characterized by X-ray diffraction, magnetometry, and electron-transport measurements. It was found that Co substitution for Mn enhances the Curie temperature of Mn 2 NiSn and both Co and Fe substitution improve its magnetization. Further, these improvements are accompanied by reduced thermal and magnetic hysteresis losses and by interesting structural changes, namely improved chemical order and site occupancies characteristic of quaternary (Y-ordered) Heuslers.

36 MATERIALS SCIENCE↗

A review of radiation-induced demagnetization of permanent magnets

Radiation-induced demagnetization of permanent magnets is important for a number of applications including space missions, particle accelerators and robots designed to carry out rescue missions at nuclear accidents where magnet failure can lead to serious consequences. This topic has been studied by several investigators over the past three decades and in this work, a review of the available literature is conducted and some general conclusions and trends are presented. In short, it can be gleaned that magnetism loss is dependent on the type of radiation, the energy of the incoming particle and the overall dose or fluence. Furthermore, magnetism loss also shows a dependence on the type of the irradiated magnet, the coercivity of the magnet, the demagnetizing field and the temperature of irradiation.

36 MATERIALS SCIENCE↗

Autonomous experimentation systems for materials development: A community perspective

Solutions to many of the world's problems depend upon materials research and development. However, advanced materials can take decades to discover and decades more to fully deploy. Humans and robots have begun to partner to advance science and technology orders of magnitude faster than humans do today through the development and exploitation of closed-loop, autonomous experimentation systems. This review discusses the specific challenges and opportunities related to materials discovery and development that will emerge from this new paradigm. Our perspective incorporates input from stakeholders in academia, industry, government laboratories, and funding agencies. We outline the current status, barriers, and needed investments, culminating with a vision for the path forward. We intend the article to spark interest in this emerging research area and to motivate potential practitioners by illustrating early successes. We also aspire to encourage a creative reimagining of the next generation of materials science infrastructure. To this end, we frame future investments in materials science and technology, hardware and software infrastructure, artificial intelligence and autonomy methods, and critical workforce development for autonomous research.

36 MATERIALS SCIENCE↗

Additive manufacturing and applications of nanomaterial-based sensors

Nanoscale materials possess distinct physical and chemical attributes including size-dependent properties, quantum confinement, high surface-to-volume ratio, and superior catalytic activity. These unique qualities enable sensors with high sensitivity, robustness, and fast time response. As the emergence of the Internet of Things (IoT) demands increased production of sensors, it also provides an impetus for concentrated nanomaterial-based sensor research. Meanwhile, additive manufacturing (AM) of nanomaterial-based sensors is critical to bridge the gap between one-off, lab-scale fabrication and cost-effective, industrial-scale production with high reproducibility. By applying the design flexibility and cost savings of AM techniques, a new generation of nanomaterial-based sensing platforms can be integrated with IoT devices in the consumer space. Furthermore, emergent research in human-machine interfaces, food safety, and point-of-care diagnostics will be expedited by the development of sensors that can be printed with irregular form factors. In this Review, the relative strengths and weaknesses of printed sensor systems based on zero-, one-, and two-dimensional nanomaterials are discussed. In addition, sensors enabled by printable soft nanomaterials, heterostructures, and nanocomposites are surveyed due to their synergistic advantages for wearable healthcare monitoring and soft robotics. Lastly, a roadmap for the next decade of research on this topic is provided.

36 MATERIALS SCIENCE↗

Interfraction rotation of the prostate as evaluated by kilovoltage X-ray fiducial marker imaging in intensity-modulated radiotherapy of localized prostate cancer

To quantify the daily rotation of the prostate during a radiotherapy course using stereoscopic kilovoltage (kV) x-ray imaging and intraprostatic fiducials for localization and positioning correction. From 2005 to 2009, radio-opaque fiducial markers were inserted into 38 patients via perineum into the prostate. The ExacTrac/Novalis Body X-ray 6-day image acquisition system (ET/NB; BrainLab AG, Feldkirchen, Germany) was used to determine and correct the target position. During the first period in 10 patients we recorded all rotation errors but used only Y (table) for correction. For the next 28 patients we used for correction all rotational coordinates, i.e., in addition Z (superior-inferior [SI] or roll) and X (left-right [LR] or tilt/pitch) according to the fiducial marker position by use of the Robotic Tilt Module and Varian Exact Couch. Rotation correction was applied above a threshold of 1 Degree-Sign displacement. The systematic and random errors were specified. Overall, 993 software-assisted rotational corrections were performed. The interfraction rotation errors of the prostate as assessed from the radiodense surrogate markers around the three axes Y, Z, and X were on average 0.09, -0.52, and -0.01 Degree-Sign with standard deviations of 2.01, 2.30, and 3.95 Degree-Sign , respectively. The systematic uncertainty per patient for prostate rotation was estimated with 2.30, 1.56, and 4.13 Degree-Sign and the mean random components with 1.81, 2.02, and 3.09 Degree-Sign . The largest rotational errors occurred around the X-axis (pitch), but without preferring a certain orientation. Although the error around Z (roll) can be compensated on average by a transformation with 4 coordinates, a significant error around X remains and advocates the full correction with 6 coordinates. Rotational errors as assessed via daily stereoscopic online imaging are significant and dominate around X. Rotation possibly degrades the dosimetric coverage of the target volume and may require suitable strategies for correction.

61 RADIATION PROTECTION AND DOSIMETRY↗

Supine proton beam craniospinal radiotherapy using a novel tabletop adapter

To develop a device that allows supine craniospinal proton and photon therapy to the vast majority of proton and photon facilities currently experiencing limitations as a result of couch design issues. Plywood and carbon fiber were used for the development of a prototype unit. Once this was found to be satisfactory after all design issues were addressed, computer-assisted design (CAD) was used and carbon fiber tables were built to our specifications at a local manufacturer of military and racing car carbon fiber parts. Clinic-driven design was done using real-time team discussion for a prototype design. A local machinist was able to construct a prototype unit for us in <2 weeks after the start of our project. Once the prototype had been used successfully for several months and all development issues were addressed, a custom carbon fiber design was developed in coordination with a carbon fiber manufacturer in partnership. CAD methods were used to design the units to allow oblique fields from head to thigh on patients up to 200 cm in height. Two custom-designed carbon fiber craniospinal tabletop designs now exist: one long and one short. Four are in successful use in our facility. Their weight tolerance is greater than that of our robot table joint (164 kg). The long unit allows for working with taller patients and can be converted into a short unit as needed. An affordable, practical means of doing supine craniospinal therapy with protons or photons can be used in most locations via the use of these devices. This is important because proton therapy provides a much lower integral dose than all other therapy methods for these patients and the supine position is easier for patients to tolerate and for anesthesia delivery. These units have been successfully used for adult and pediatric supine craniospinal therapy, proton therapy using oblique beams to the low pelvis, treatment of various spine tumors, and breast-sparing Hodgkin's therapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Phantom-to-clinic development of hypofractionated stereotactic body radiotherapy for early-stage glottic laryngeal cancer

The purpose of this study was to commission and clinically test a robotic stereotactic delivery system (CyberKnife, Sunnyvale, CA) to treat early-stage glottic laryngeal cancer. We enrolled 15 patients with cTis-T2N0M0 carcinoma of the glottic larynx onto an institutional review board (IRB)-approved clinical trial. Stereotactic body radiotherapy (SBRT) plans prescribed 45 Gy/10 fractions to the involved hemilarynx. SBRT dosimetry was compared with (1) standard carotid-sparing laryngeal intensity-modulated radiation therapy (IMRT) and (2) selective hemilaryngeal IMRT. Our results demonstrate that SBRT plans improved sparing of the contralateral arytenoid (mean 20.0 Gy reduction, p <0.001), ipsilateral carotid D{sub max} (mean 20.6 Gy reduction, p <0.001), contralateral carotid D{sub max} (mean 28.1 Gy reduction, p <0.001), and thyroid D{sub mean} (mean 15.0 Gy reduction, p <0.001) relative to carotid-sparing IMRT. SBRT also modestly improved dose sparing to the contralateral arytenoid (mean 4.8 Gy reduction, p = 0.13) and spinal cord D{sub max} (mean 4.9 Gy reduction, p = 0.015) relative to selective hemilaryngeal IMRT plans. This “phantom-to-clinic” feasibility study confirmed that hypofractionated SBRT treatment for early-stage laryngeal cancer can potentially spare dose to adjacent normal tissues relative to current IMRT standards. Clinical efficacy and toxicity correlates continue to be collected through an ongoing prospective trial.

61 RADIATION PROTECTION AND DOSIMETRY↗

Cyberknife stereotactic radiosurgery and radiation therapy treatment planning system

CyberKnife is an image-guided stereotactical dose delivery system designed for both focal irradiation and radiation therapy (SRT). Focal irradiation refers the use of many small beams to deliver highly focus dose to a small target region in a few fractions. The system consists of a 6-MV linac mounted to a robotic arm, coupled with a digital x-ray imaging system. The radiation dose is delivered using many beams oriented at a number of defined or nodal positions around the patients. The CyberKnife can be used for both intracranial and extracranial treaments unlike the Gamma Knife which is limited to intracranial cases. Multiplan (Accuray Inc., Sunnyvale, CA) is the treatment planning system developed to cooperate with this accurate and versatile SRS and SRT system, and exploit the full function of Cyberknife in high-precision radiosurgery and therapy. Optimized inverse treatment plan can be achieved by fine-tuning contours and planning parameters. Precision is the newest version of Cyberknife treatment planning system (TPS) and an upgrade to Multiplan. It offers several new features such as Monte Carlo for multileaf collimator (MLC) and retreatment for other modalities that added more support for the Cyberknife system. The Cybeknife TPS is an easy-to-use and versatile inverse planning platform, suitable for stereotactic radiosurgery and radiation therapy. The knowledge and experience of the planner in this TPS is essential to improve the quality of patient care.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

All-polymer nanocomposites having superior strength, toughness and ultralow energy dissipation

Toughening polymers has attracted significant interest. Traditionally, polymer toughness is enhanced by constructing polymer networks or introducing sacrificial bonds into the chains between crosslink points. These strategies, though, introduce pronounced energy dissipation and associated heat, both of which are undesirable under long-term cyclic loading, for example at the interface of implants in the human body. By incorporating single-chain nanoparticles (SCNPs) into linear polymer chains to generate all-polymer nanocomposites (APNCs), we have been able to achieve high strength, high toughness with low energy dissipation. Using a combination of simulation and experimental results, we are advancing a “SCNPs effect” where tightly cross-linked SCNPs produce a modulus contrast to achieve strengthening and toughening. Benefitting from the soft interface, the penetrable and deformable SCNPs cause the surrounding polymer chains to move in concert, significantly reducing the interfacial friction to achieve low energy dissipation. The intramolecular cross-linking of the SCNPs and adhesion between the SCNPs and polymer matrix are critical for realizing such high-performance systems. Based on a Gaussian regression model and back propagation (BP) neural network, the mechanical strength can be predicted and is supported by simulations. Finally, the APNC concept described can be applied to elastomers and gels, broadening its utilization in high-cycle and low-dissipation applications, like soft robots, flexible sensors and cartilage replacements, and artificial heart valves.

36 MATERIALS SCIENCE↗

Formation of helices with controllable chirality in gel-fiber composites

While microscale helices with specified chirality are pervasive in biological systems, driving purely synthetic materials to self-organize into such useful structures remains a significant challenge. Through theory and simulations, we model the behavior of initially flat ribbons of gel-fiber composites and show that these materials self-organize into three-dimensional helices with the application of heat. We specifically focus on thermo-responsive gels, which shrink when heated to a point near the lower critical solubility temperature (LCST). Within the composite, regions of the LCST gel that lie far from the fibers can readily shrink in response to the increased temperature; however, near the fibers the network is inhibited from undergoing the heat-induced collapse. This competition between the constrained and the unconstrained regions of the heated sample plays a vital role in the structural evolution of the material. Additionally, we find that this dynamic process can be controlled through the careful placement of the fibers on the outer surface of the gel. We specifically identify fiber arrangements that lead to the formation of helical structures with controlled chirality. Moreover, we isolate scenarios where constraining the movement of one or both the free ends of the sample promotes and stabilizes the formation of helical structures with specified handedness. Such structurally tailored composites are useful for creating mechanically robust actuators, and “appendages” for soft robots that can controllably curl and uncurl with variations in temperature.

36 MATERIALS SCIENCE↗

Functional stimuli-responsive polymers on micro- and nano-patterned interfaces

Micro- and nano-patterned surfaces offer precise control over morphology and chemical composition, enhancing the stability, durability, and functionality of coating materials. When combined with stimuli-responsive polymers, these surfaces gain dynamic adaptability, enabling reversible binding, reusable sensing, and selective molecular capture. Furthermore, while recent review articles have explored various aspects of stimuli-responsive materials, from hydrogel patterns for bioanalytical applications to shape-morphing hydrogels for soft robotics and sensors, a comprehensive review focused on the integration of smart polymers with micro- or nano-patterned interfaces remains absent. This review addresses key surface patterning techniques, including soft lithography, colloidal lithography, and polymer brush photolithography, as well as advances in surface-initiated polymerization methods, such as surface-initiated controlled radical polymerization (SI-CRP). In addition, we discuss recent progress in integrating stimuli-responsive polymers with patterned surfaces to create advanced, functional materials.

Colloidal lithography↗