Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

The Integrated Reference Region Analysis for Parallel DFIGs’ Interfacing Inductors

Although the traditional design of doubly-fed induction generators (DFIGs)’ interfacing inductors consider the peak ripple of the grid-side converter (GSC)’s output current, it does not consider the inductors’ impact on DFIGs’ smallsignal stability. Located in series between the GSC and the stator, the inappropriate selection of the interfacing inductor can easily result to system instability. Therefore, this paper first proposes the integrated reference region analysis for small wind farm's interfacing inductors to improve the traditional design method. Firstly, a new detailed parallel DFIGs’ smallsignal model that considers output currents’ coupling is built in d-q coordinate system with state-space approach. The model focuses on representing the operating states of parallel DFIGs in wind farm. Secondly, the linearized state-space matrix of parallel DFIGs is decomposed into nominal-value matrix and location matrix. Considering the traditional design requirements, the integrated reference region for interfacing inductor is proposed through spectral radius and bialternate matrix sum (BMS). Furthermore, it can provide better guidance for parameter selecting and stabilization method researches. Finally, the simulation and experimental results show that the proposed integrated reference region for parallel DFIGs’ interfacing inductors is accurate and instructive.

47 OTHER INSTRUMENTATION↗

Groundwater and Surface Water Flow (GSFLOW) model files to explore bedrock circulation depth and porosity in Copper Creek, Colorado

This data package contains integrated hydrological model input and output files for Copper Creek, Colorado (24 km2), a tributary of the East River located in the headwaters of the Upper Colorado River Basin. The model code is the U.S. Geological Survey (USGS) Groundwater and Surface Water Flow (GSFLOW) model. The model contains a 100-m grid resolution and a daily timestep. The land surface model is dynamically linked to a three-dimensional groundwater flow model that allows for streamflow gaining and losing conditions. The groundwater model contains 12 model layers and extends 400 m below land surface. The original Copper Creek model was modified to contain geologic layers representing saprolite, shallow bedrock, and deep bedrock. Endmember depth versus hydraulic conductivity relationships and porosity values for fractured crystalline rock are simulated. For the shallow case, median flow depths occur in the shallow saprolite at depths <8 m, while the deep case promotes a median groundwater flow depth of 100 m. With this modeling framework we compare streamflow response to a plausible worst-case drought lasting up to five years. Streamflow metrics of analysis include average streamflow, fraction of stream network that is dry, no-flow duration, average groundwater flow to streams and time to recovery following the drought. Results and implications are presented in a paper submitted to Geophysical Research Letters titled, "The role of bedrock circulation depth and porosity in mountain streamflow response to prolonged drought" by Rosemary WH. Carroll, Andrew H. Manning and Kenneth H Williams. A Readme.txt file provides instructions on how to download all model files and execute each model scenario. In addition to the GSFLOW output/prms/copper_drought.csv file containing daily basin water stores and fluxes (refer to GSFLOW manual) and the output/prms/copper_drought_statvar.dat file with output defined in the gsflow3.control file (refer to GSFLOW Manual), output files also include spatially distributed daily values of total evapotranspiration, canopy evaporation, precipitation, snowfall, infiltration, snow water equivalent, potential evapotranspiration, recharge, sublimation, soil moisture, contributing interflow, water table elevations, changes in groundwater storage, groundwater evapotranspiration, interbasin groundwater flow (limited to the alluvium below the stream outlet), and surface-groundwater exchanges within the river system.

54 ENVIRONMENTAL SCIENCES↗

Assessing operating characteristics of CAD algorithms in the absence of a gold standard

Purpose: The authors examine potential bias when using a reference reader panel as ''gold standard'' for estimating operating characteristics of CAD algorithms for detecting lesions. As an alternative, the authors propose latent class analysis (LCA), which does not require an external gold standard to evaluate diagnostic accuracy. Methods: A binomial model for multiple reader detections using different diagnostic protocols was constructed, assuming conditional independence of readings given true lesion status. Operating characteristics of all protocols were estimated by maximum likelihood LCA. Reader panel and LCA based estimates were compared using data simulated from the binomial model for a range of operating characteristics. LCA was applied to 36 thin section thoracic computed tomography data sets from the Lung Image Database Consortium (LIDC): Free search markings of four radiologists were compared to markings from four different CAD assisted radiologists. For real data, bootstrap-based resampling methods, which accommodate dependence in reader detections, are proposed to test of hypotheses of differences between detection protocols. Results: In simulation studies, reader panel based sensitivity estimates had an average relative bias (ARB) of -23% to -27%, significantly higher (p-value <0.0001) than LCA (ARB -2% to -6%). Specificity was well estimated by both reader panel (ARB -0.6% to -0.5%) and LCA (ARB 1.4%-0.5%). Among 1145 lesion candidates LIDC considered, LCA estimated sensitivity of reference readers (55%) was significantly lower (p-value 0.006) than CAD assisted readers' (68%). Average false positives per patient for reference readers (0.95) was not significantly lower (p-value 0.28) than CAD assisted readers' (1.27). Conclusions: Whereas a gold standard based on a consensus of readers may substantially bias sensitivity estimates, LCA may be a significantly more accurate and consistent means for evaluating diagnostic accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization and Uncertainty Analysis of a Reference Pressure Measurement System for Wind Tunnels

This paper presents the calibration results and uncertainty analysis of a high-precision reference pressure measurement system currently used in wind tunnels at the NASA Langley Research Center (LaRC). Sensors, calibration standards, and measurement instruments are subject to errors due to aging, drift with time, environment effects, transportation, the mathematical model, the calibration experimental design, and other factors. Errors occur at every link in the chain of measurements and data reduction from the sensor to the final computed results. At each link of the chain, bias and precision uncertainties must be separately estimated for facility use, and are combined to produce overall calibration and prediction confidence intervals for the instrument, typically at a 95% confidence level. The uncertainty analysis and calibration experimental designs used herein, based on techniques developed at LaRC, employ replicated experimental designs for efficiency, separate estimation of bias and precision uncertainties, and detection of significant parameter drift with time. Final results, including calibration confidence intervals and prediction intervals given as functions of the applied inputs, not as a fixed percentage of the full-scale value are presented. System uncertainties are propagated beginning with the initial reference pressure standard, to the calibrated instrument as a working standard in the facility. Among the several parameters that can affect the overall results are operating temperature, atmospheric pressure, humidity, and facility vibration. Effects of factors such as initial zeroing and temperature are investigated. The effects of the identified parameters on system performance and accuracy are discussed.

Amer, Tahani↗

Outdoor characterization of radio frequency electromagnetic fields in a Spanish birth cohort

There is considerable public concern in many countries about the possible adverse effects of exposure to non-ionizing radiation electromagnetic fields, especially in vulnerable populations such as children. The aim of this study was to characterize environmental exposure profiles within the frequency range 100 kHz–6 GHz in the immediate surrounds of the dwellings of 123 families from the INMA-Granada birth cohort in Southern Spain, using spot measurements. The arithmetic mean root mean-square electric field (E{sub RMS}) and power density (S{sub RMS}) values were, respectively, 195.79 mV/m (42.3% of data were above this mean) and 799.01 µW/m{sup 2} (30% of values were above this mean); median values were 148.80 mV/m and 285.94 µW/m{sup 2}, respectively. Exposure levels below the quantification limit were assigned a value of 0.01 V/m. Incident field strength levels varied widely among different areas or towns/villages, demonstrating spatial variability in the distribution of exposure values related to the surface area population size and also among seasons. Although recorded values were well below International Commission for Non-Ionizing Radiation Protection reference levels, there is a particular need to characterize incident field strength levels in vulnerable populations (e.g., children) because of their chronic and ever-increasing exposure. The effects of incident field strength have not been fully elucidated; however, it may be appropriate to apply the precautionary principle in order to reduce exposure in susceptible groups. - Highlights: • Spot measurements were performed in the immediate surrounds of children's dwellings. • Mean root mean-square electric field and power density values were calculated. • Most recorded values were far below international standard guideline limits. • Data demonstrate spatial variability in the distribution of exposure levels. • While adverse effects are proven, application of the precautionary principle may be appropriate.

54 ENVIRONMENTAL SCIENCES↗

SU-F-T-31: Shape and Isodose Distributions in Co60 HDR Brachytherapy for Different Utero-Vaginal Time Ratios

Purpose: To optimize the dose in bladder and rectum and show the different shapes of the isodose volumes in Co60-HDR brachytherapy, considering different utero and vaginal sources dwell ratio times (TU:TV). Methods: Besides Ir192-HDR, new Co60-HDR sources are being incorporated. We considered different TU:TV times and computed the dosis in bladder, rectum and at the reference points of the Manchester system. Also, we calculated the isodose volume and shape in each case. We used a EZAG-BEBIG Co0.A86 model with TPS HDRplus3.0.4. and LCT42-7, LCT42-2(R,L) applicators. A reference dose RA= 1.00 Gy was given to the A-right point. We considered the TU:TV dwell time ratios 1:0.25, 1:0.33, 1:0.5, 1:1, 1:2, 1:3, and 1:4. Given TU:TV, the stop time at each dwell position is fixed for each applicator. Results: Increasing TU:TV systematically results in a decreasing of the dose in bladder and rectum, e.g. 9% and 27% reduction were found in 1:0.25 with respect to 1:1, while 12% and 34% increase were found in 1:4 with respect to 1:1. Also, the isodose volume parameters height (h), width (w), thickness (t) and volume (hwt) increased from the 1:0.25 case to the 1:4 value: hwt is 25% lower and 31% higher than the 1:1 reference volume in these cases. Also w decreased for higher TU:TV and may compromise the tumoral volume coverage, decreasing 17% in the 1:0.25 case compared to the 1:1 case. The shape of the isodose volume was obtained for the different TU:TV considered. Conclusion: We obtained the shape of isodose volumes for different TU:TV values in gynecological Co60-HDR. We studied the dose reduction in bladder and rectum for different TU:TV ratios. The volume parameters and hwt are strongly dependent on this ratio. This information is useful for a quantitative check of the TPS and as a starting point towards optimization.

60 APPLIED LIFE SCIENCES↗

Calibration of imaging plates to electrons between 40 and 180 MeV

This paper presents the response calibration of Imaging Plates (IPs) for electrons in the 40-180 MeV range using laser-accelerated electrons at Laboratoire d’Optique Appliquée (LOA), Palaiseau, France. In the calibration process, the energy spectrum and charge of electron beams are measured by an independent system composed of a magnetic spectrometer and a Lanex scintillator screen used as a calibrated reference detector. It is possible to insert IPs of different types or stacks of IPs in this spectrometer in order to detect dispersed electrons simultaneously. The response values are inferred from the signal on the IPs, due to an appropriate charge calibration of the reference detector. The effect of thin layers of tungsten in front and/or behind IPs is studied in detail. GEANT4 simulations are used in order to analyze our measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Damage Detection of CFRP Plates by Full-Spectral Analysis of a Fibre Bragg Grating Sensor Signal

This paper describes the measurement of average strain, strain distribution and vibration of cantilever beam made of Carbon Fiber Reinforced Plastics (CFRP), using a single Fibre Bragg Grating (FBG) sensor mounted on the beam surface. Average strain is determined from the displacement of the peak wavelength of reflected light from the FBG sensor. Unstrained reference FBG sensors were used to compensate for temperature drift and the photoelastic coefficient (P{sub e}), which was used to calculate the gauge factor. Measured strains agree with those measured by a resistance foil strain gauge attached to the sample. Stress distributions are measured by monitoring the variation in the full width half maximum (FWHM) values of the reflected spectrum, using a proposed optical analytical model, described in the paper. FWHM values were measured for both the cantilever test beam and a for a reference beam, loaded using a four-point bending rig. The trend of the stress distribution for the test beam matches with our analytical model, however with a relatively large noise present in the experimentally determined data. The vibration of cantilever beam was measured by temporal analysis of the peak reflection wavelength. This technique is very stable as measurements are not affected by variations in the signal amplitude. Finally an application of FBG sensors for damage detection of CFRP plates is demonstrated, by measuring the average strain and natural frequency. With small defects of different sizes applied to the CFRP plate, average strains were seen to increase with damage size and the natural frequency decreased with damage size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Product Consistency Test Results for the LAW HPVR Glasses

This report summarizes the chemical analysis of Product Consistency Test (PCT) leachates received from Pacific Northwest National Laboratory (PNNL). The leachates are from a series of simulated nuclear waste glasses designated Low-Activity Waste High PCT and VHT Response (LAW HPVR) glasses that were designed and fabricated at PNNL. The glasses included both quenched and canister centerline cooled glasses. The reported data will be used in the development, validation, and implementation of enhanced property/composition models for waste glass vitrification at Hanford. The elemental release for the study glasses is reported as normalized concentration (NC i ). NC i of several elements was computed for both the target and measured glass compositions, which were similar, resulting in no significant differences when computing the NC i values. The majority of the glasses exhibited NC B , NC Na , and NC Si values that were greater than the Hanford Tank Waste Treatment Plant (WTP) low-activity waste constraint of 4 g/L. Several blank solutions included with the study glasses had K, Na, and Si concentrations above the analytical detection limit. Additionally, several of the reference glasses that were included with the study glasses had Na concentrations that were higher than expected. The unexpected analyte concentrations in the reference glass and blank solutions were insignificant with respect to the reported NC i values, and are noted for completeness and their experimental relevance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Exploratory Investigation of Aerodynamic Flameholders for Afterburner Application

An investigation was conducted to determine the flameholding capabilities of aerodynamic jets at afterburner operating conditions. Stability data for a number of aerodynamic flameholders were obtained in a 5- by 5-inch test section at inlet-air reference velocities up to 600 feet per second, an inlet-air temperature of 1250 F, and a combustor-inlet pressure of 15 inches of mercury absolute. Combustion efficiency and stability data of the more promising combinations were then obtained in a 10- by 12-inch test section at the same test conditions. Both air and stoichiometric mixtures of fuel and air were used in the jets; mixture flow rates were approximately 1 percent by weight of the total air-flow rate. Injection pressures were limited to values that might be available from compressor-bleed air. At a reference velocity of 600 feet per second, aerodynamic flame-holders alone were unable to maintain a stable flame at injection pressures up to 70 pounds per square inches large reductions in velocity were required to achieve flame stabilization. When the aerodynamic jets were used in combination with a V-gutter flameholder with approximately a 30 percent blocked area, flame stabilization was attained at a velocity of 600 feet per second; however, the combustion efficiencies of the various combinations were no greater than that obtained with the V-gutter alone.

Butze, Helmut F.↗

Dynamic PET Measures of Tau Accumulation in Cognitively Normal Older Adults and Alzheimer’s Disease Patients Measured Using [18F] THK-5351

Background [ 18F]THK5351, a recently-developed positron emission tomography (PET) tracer for measuring tau neurofibrillary tangle accumulation, may help researchers examine aging, disease, and tau pathology in living human brains. We examined THK5351 tracer pharmacokinetics to define an optimal acquisition time for static late images. Methods Primary measurements were calculation of regional values of distribution volume ratios (DVR) and standardized uptake value ratios (SUVR) in 6 healthy older control and 10 Alzheimer’s disease (AD) participants. We examined associations between DVR and SUVR, searching for a 20 min SUVR time window that was stable and comparable to DVR. We additionally examined diagnostic group differences in this 20 min SUVR. Results In healthy controls, [18F]THK5351 uptake was low, with increased temporal relative to frontal binding. In AD, regional uptake was substantially higher than in healthy controls, with temporal exceeding frontal binding. Retention in cerebellar gray matter, which was used as the reference region, was low compared to other regions. Both DVR and SUVR values showed minimal change over time after 40 min. SUVR 20–40, 30–50, and 40–60 min were most consistently correlated with DVR; SUVR 40–60 min, the most stable time window, was used in further analyses. Significant (AD > healthy control) group differences existed in temporoparietal regions, with marginal medial temporal differences. We found high basal ganglia SUVR 40–60 min signal, with no group differences. Conclusions We examined THK5351, a new PET tracer for measuring tau accumulation, and compared multiple analysis methods for quantifying regional tracer uptake. SUVR 40–60 min performed optimally when examining 20 min SUVR windows, and appears to be a practical method for quantifying relative regional tracer retention. The results of this study offer clinical potential, given the usefulness of THK5351-PET as a biomarker of tau pathology in aging and disease.

60 APPLIED LIFE SCIENCES↗

Cited Reference Analysis in a National Laboratory to Assess Journal Usage

Librarians at a large, federally funded, multidisciplinary research organization sought to assess the value provided by the library’s collections. One method for capturing this value includes determining how well their library’s collections meet researcher needs, as expressed by the materials those researchers choose to cite in the production of new scholarly communications. A cited reference analysis was performed on the publications originating from the institution to provide the necessary data for the assessment, as well as to aid in the creation of a core list of journals which will inform future collection development efforts. Overall, this paper fills a gap in the library and information science literature by addressing the citation behaviors of researchers at a large multidisciplinary government research facility, a setting that has not been examined previously.

99 GENERAL AND MISCELLANEOUS↗

Large Area Crop Inventory Experiment (LACIE). Effect of sun angle and haze on generation of LANDSAT imagery

The author has identified the following significant results. When heavy haze was present over a nonvegetated scene, the mean radiance values for all MSS channels were lowered, with the greatest decrease occurring in channels 1 and 2. Over a vegetated scene, any apparent decrease in mean radiance values due to haze may be marked by an increase in mean radiance values which occurred as vegetation increased in vigor during its growth cycle. Mean radiance values for nonvegetated targets (except water) were closely correlated to the changes in sun elevation angle throughout the year. A sun angle correction to a fixed reference data appeared to offer the possibility of compensating for haze covered areas by predicting the mean radiance values which would be closely correlated to the normal sun declination curve.

Chesnutwood, C. M.↗

Assessment of High Resolution Commercial Satellite Geolocation Accuracy

Commercial companies such as Maxar, PlanetScope, and BlackSky have launched many satellites with revisit times ranging from two hours to one day and have built large archives of high resolution (1-3 m) Earth observing data. The high temporal resolution and global coverage of these satellites makes commercial satellite images ideal for scientists studying rapidly changing processes such as flooding and fires. A key step in assessing changes in these images is co-registration of various images to each other. High geolocation accuracy (at most 0.5 pixels of offset) allows for easy co-registration of images across different times and sensors. Here, we assess the latest PlanetScope imagery and evaluate it for geolocation accuracy. For our assessment, we compare the target image to a reference image with known geolocation accuracy (WorldView imagery) and determine the offset between these images by shifting them to maximize their Pearson Cross-Correlation (PCC) value. Offsets required to maximize the PCC give the geolocation accuracy of the target image relative to the reference image. Previously, our global assessment of Planet data revealed large variability in geolocation accuracy from one continent to another. The measured root mean squared errors (RMSEs) range from 5.4 m in North America to 14.9 m in Africa. We have updated this previous assessment to include both their newest SuperDove series as well as a more robust assessment of the temporal stability of PlanetScope's geolocation accuracy.

Alana G. Semple↗

Meta-Analysis of Advanced Nuclear Reactor Cost Estimations

Supporting Data can be downloaded at: https://gain.inl.gov/content/uploads/4/2024/06/INL-RPT-24-77048-R1.xlsx Nuclear energy is a critical cornerstone of the current United States clean energy supply and may play a larger role in the future in support of a transition to a net-zero economy. The current fleet of nuclear reactors predominantly consists of large light-water reactors (LWRs), while many of the reactor designs under consideration are smaller and/or different technologies. Because these new designs have not yet been built, there is a high degree of uncertainty associated with their cost. This complicates energy-planning efforts because cost projections are not always standardized, consistent, and centralized in an easily accessible location. To help support energy planning in the US, this report provides advanced nuclear cost ranges using a transparent methodology along with other relevant information that can be used to help support decision making and energy planning. The purpose of this work was to conduct a methodical process for cost evaluation using only public information that was vetted with the end-goal to provide reference cost projections for nuclear energy. To provide a solid basis for these values, the approach and assumptions are explicitly laid out throughout the report allowing any user of the data to challenge or reconsider them. Because future US nuclear-reactor costs are still unknown due to little recent observed data, the report opted to compile a comprehensive list of bottom-up estimates and evaluate averages/trends within the data to identify reference ranges. This was deemed preferable to opining on the robustness or validity of one cost estimation versus another. To that end, the work evaluated thousands of lines of cost subaccounts from several bottom-up cost estimates. A wide variety of different reactor types captured in the data are of various sizes and technologies. Some of these reactors will be representative of advanced reactors under development while others will not. Thus, the results here are dependent on the data that are available and the accuracy of the estimates that are used. Each bottom-up estimate was reviewed to determine whether it was complete. Incomplete data sets were corrected to ensure an adequate basis of cross-comparison. The report is not without limitations and should be interpreted as an initial step to develop cost ranges for nuclear technology. Ultimately, future work can build upon the methodology with refined cost estimates to reduce uncertainty. US-based overnight capital cost (OCC) estimates were compiled from extensive data sets into ranges for both large and small reactor sizes for 2030. To project the cost declines over time, learning rates were sampled from literature sources. No SMRs were previously built; hence, learning rates based on bottom-up approaches (e.g., by quantifying the impact stemming from fabrication of different components, modular work, site construction, commissioning) were prioritized. For larger reactors, actual learning rates from deployments were used to project future costs (adjusted to account for standardization or lack thereof between designs). Other costs included are fixed and variable operations and maintenance costs. The final variables were capacity factors and ramp rates to support energy planning.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Reference dosimetry at the Australian Synchrotron's imaging and medical beamline using free-air ionization chamber measurements and theoretical predictions of air kerma rate and half value layer

Purpose: Novel, preclinical radiotherapy modalities are being developed at synchrotrons around the world, most notably stereotactic synchrotron radiation therapy and microbeam radiotherapy at the European Synchrotron Radiation Facility in Grenoble, France. The imaging and medical beamline (IMBL) at the Australian Synchrotron has recently become available for preclinical radiotherapy and imaging research with clinical trials, a distinct possibility in the coming years. The aim of this present study was to accurately characterize the synchrotron-generated x-ray beam for the purposes of air kerma-based absolute dosimetry. Methods: The authors used a theoretical model of the energy spectrum from the wiggler source and validated this model by comparing the transmission through copper absorbers (0.1-3.0 mm) against real measurements conducted at the beamline. The authors used a low energy free air ionization chamber (LEFAC) from the Australian Radiation Protection and Nuclear Safety Agency and a commercially available free air chamber (ADC-105) for the measurements. The dimensions of these two chambers are different from one another requiring careful consideration of correction factors. Results: Measured and calculated half value layer (HVL) and air kerma rates differed by less than 3% for the LEFAC when the ion chamber readings were corrected for electron energy loss and ion recombination. The agreement between measured and predicted air kerma rates was less satisfactory for the ADC-105 chamber, however. The LEFAC and ADC measurements produced a first half value layer of 0.405 {+-} 0.015 and 0.412 {+-} 0.016 mm Cu, respectively, compared to the theoretical prediction of 0.427 {+-} 0.012 mm Cu. The theoretical model based upon a spectrum calculator derived a mean beam energy of 61.4 keV with a first half value layer of approximately 30 mm in water. Conclusions: The authors showed in this study their ability to verify the predicted air kerma rate and x-ray attenuation curve on the IMBL using a simple experimental method, namely, HVL measurements. The HVL measurements strongly supports the x-ray beam spectrum, which in turn has a profound effect on x-ray dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

Method for Correcting Control Surface Angle Measurements in Single Viewpoint Photogrammetry

A method of determining a corrected control surface angle for use in single viewpoint photogrammetry to correct control surface angle measurements affected by wing bending. First and second visual targets are spaced apart &om one another on a control surface of an aircraft wing. The targets are positioned at a semispan distance along the aircraft wing. A reference target separation distance is determined using single viewpoint photogrammetry for a "wind off condition. An apparent target separation distance is then computed for "wind on." The difference between the reference and apparent target separation distances is minimized by recomputing the single viewpoint photogrammetric solution for incrementally changed values of target semispan distances. A final single viewpoint photogrammetric solution is then generated that uses the corrected semispan distance that produced the minimized difference between the reference and apparent target separation distances. The final single viewpoint photogrammetric solution set is used to determine the corrected control surface angle.

Burner, Alpheus W.↗

E-KIT: An Electronic-Knowledge Information Tool for Organizing Site Information and Improving Technical Communication with Stakeholders - 13082

Managing technical references for projects that have long histories is hampered by the large collection of documents, each of which might contain discrete pieces of information relevant to the site conceptual model. A database application has been designed to improve the efficiency of retrieving technical information for a project. Although many databases are currently used for accessing analytical and geo-referenced data, applications designed specifically to manage technical reference material for projects are scarce. Retrieving site data from the array of available references becomes an increasingly inefficient use of labor. The electronic-Knowledge Information Tool (e-KIT) is designed as a project-level resource to access and communicate technical information. The e-KIT is a living tool that grows as new information becomes available, and its value to the project increases as the volume of site information increases. Having all references assembled in one location with complete reference citations and links to elements of the site conceptual model offers a way to enhance communication with outside groups. The published and unpublished references are incorporated into the e-KIT, while the compendium of references serves as a complete bibliography for the project. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗