Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Process Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Achieving Runtime State Verification Assurance in Critical Cyber-Physical Infrastructures

Industrial Cyber-Physical Systems (ICPS) are an essential backbone of national critical infrastructures. They help monitor and control crucial cyber-enabled services such as energy generation. Commonly ICPS monitors the physical process through Supervisory Control and Data Acquisition (SCADA) systems. The SCADA ecosystem takes critical real-time and future system operational decisions based on the runtime state behavior of field sensors. Traditional SCADA systems use legacy and insecure communication protocols such as the Modbus protocol that lack adequate security mechanisms to provide robust runtime state behavior assurance of constrained field sensors. Therefore, constrained field sensors are commonly vulnerable to standard semantic attacks that gradually change the behavior state of infected devices. This paper discusses process integrity assurance techniques necessary to enhance the security of behavior-based protocols such as the Modbus protocol. The Runtime State Verification (RSV) protocol proposed in this paper aims to address semantic attacks in the SCADA ecosystem by integrating behavior-based Mandatory Results Automata (MRA) and a Hyperledger Fabric (HLF) network. The RSV protocol provides high process integrity assurance through enhanced behavior-based MRA suitable for the constrained field devices. A proof of concept of the RSV protocol has been evaluated in an emulated water-tube boiler. Preliminary evaluations of the RSV protocol aimed to measure the efficiency of the proposed protocol by monitoring an Combustion Efficiency (CE) process necessary to preserve optimal combustion, thus minimizing costs and future maintenance of water-tube boilers. We analyze the overall network overhead and latency of the proposed RSV protocol by evaluating the HLF network performance and comparing the proposed RSV protocol with the state-ofart BloSPAI protocol. Through the preliminary evaluations of the proposed RSV protocol, this paper demonstrates that the proposed RSV protocol overcomes the shortcomings and network overhead of the BloSPAI protocol by integrating behavior-based authentication through novel MRAs and HLF networks.

Rivera, Abel Gomez↗

Correlation Processing Of Local Seismic Data: Applications for Autonomous Sensor Deployments

Excavation and operation of an underground facility is likely to produce an extensive suite of seismic signals observable at the surface for perhaps several km. Probably a large fraction of such signals will be correlated, so the design of a monitoring framework should include consideration of a correlation processing capability. Correlation detectors have been shown to be significantly more sensitive than beam-forming power detectors. Although correlation detectors have a limited detection footprint, they can be generalized into multi-rank subspace detectors which are sensitive over a much larger range of source mechanisms and positions. Production of subspace detectors can be automated, so their use in an autonomous framework may be contemplated. Waveform correlation also can be used to produce very high precision phase picks which may be jointly inverted to simultaneously relocate groups of events. The relative precision of the resulting hypocenters is sufficient to visualize structural detail at a scale of less than a few tens of meters. Three possible correlation processor systems are presented. All use a subspace signal detection framework. The simplest system uses a single-component sensor and is capable of detection and classification of signals. The most complicated system uses many sensors deployed around the facility, and is capable of detection, classification, and high-precision source location. Data from a deep underground mine are presented to demonstrate the applicability of correlation processing to monitoring an underground facility. Although the source region covers an area of about 600m by 580m, all but two of the events form clusters at a threshold of 0.7. All the events could have been detected and classified by the subspace detection framework, and high-precision picks can be computed for all cluster members.

58 GEOSCIENCES↗

Multileaf collimator performance monitoring and improvement using semiautomated quality control testing and statistical process control

Purpose: High-quality radiation therapy using highly conformal dose distributions and image-guided techniques requires optimum machine delivery performance. In this work, a monitoring system for multileaf collimator (MLC) performance, integrating semiautomated MLC quality control (QC) tests and statistical process control tools, was developed. The MLC performance monitoring system was used for almost a year on two commercially available MLC models. Control charts were used to establish MLC performance and assess test frequency required to achieve a given level of performance. MLC-related interlocks and servicing events were recorded during the monitoring period and were investigated as indicators of MLC performance variations. Methods: The QC test developed as part of the MLC performance monitoring system uses 2D megavoltage images (acquired using an electronic portal imaging device) of 23 fields to determine the location of the leaves with respect to the radiation isocenter. The precision of the MLC performance monitoring QC test and the MLC itself was assessed by detecting the MLC leaf positions on 127 megavoltage images of a static field. After initial calibration, the MLC performance monitoring QC test was performed 3–4 times/week over a period of 10–11 months to monitor positional accuracy of individual leaves for two different MLC models. Analysis of test results was performed using individuals control charts per leaf with control limits computed based on the measurements as well as two sets of specifications of ±0.5 and ±1 mm. Out-of-specification and out-of-control leaves were automatically flagged by the monitoring system and reviewed monthly by physicists. MLC-related interlocks reported by the linear accelerator and servicing events were recorded to help identify potential causes of nonrandom MLC leaf positioning variations. Results: The precision of the MLC performance monitoring QC test and the MLC itself was within ±0.22 mm for most MLC leaves and the majority of the apparent leaf motion was attributed to beam spot displacements between irradiations. The MLC QC test was performed 193 and 162 times over the monitoring period for the studied units and recalibration had to be repeated up to three times on one of these units. For both units, rate of MLC interlocks was moderately associated with MLC servicing events. The strongest association with the MLC performance was observed between the MLC servicing events and the total number of out-of-control leaves. The average elapsed time for which the number of out-of-specification or out-of-control leaves was within a given performance threshold was computed and used to assess adequacy of MLC test frequency. Conclusions: A MLC performance monitoring system has been developed and implemented to acquire high-quality QC data at high frequency. This is enabled by the relatively short acquisition time for the images and automatic image analysis. The monitoring system was also used to record and track the rate of MLC-related interlocks and servicing events. MLC performances for two commercially available MLC models have been assessed and the results support monthly test frequency for widely accepted ±1 mm specifications. Higher QC test frequency is however required to maintain tighter specification and in-control behavior.

07 ISOTOPE AND RADIATION SOURCES↗

Characterization of and sensor-model verification and control of the properties of PMR-13 during processing

This study presents an in situ sensor and a process-simulation model developed for monitoring and controlling the cure process of PMR-15. The time-temperature dependence of the buildup in the molecular network structure, extent of reaction, viscosity, flow, and consolidation during the cure of PMR-15 are discussed. The relationship of the time-temperature cycle used during imidization to the length of the endcapped chains formed is examined. The relationship of the time-temperature cure-processing cycle to the reaction kinetics, viscosity, flow, and consolidation during crosslinking is analyzed using frequency-dependent electromagnetic sensors and the Loos processing model. Application of the FDEMS sensing technique and the process-simulation model for quality assurance processing and automated on-line control of cure is discussed.

Kranbuehl, D.↗

Microfabricated Hydrogen Sensor Technology for Aerospace and Commercial Applications

Leaks on the Space Shuttle while on the Launch Pad have generated interest in hydrogen leak monitoring technology. An effective leak monitoring system requires reliable hydrogen sensors, hardware, and software to monitor the sensors. The system should process the sensor outputs and provide real-time leak monitoring information to the operator. This paper discusses the progress in developing such a complete leak monitoring system. Advanced microfabricated hydrogen sensors are being fabricated at Case Western Reserve University (CWRU) and tested at NASA Lewis Research Center (LeRC) and Gencorp Aerojet (Aerojet). Changes in the hydrogen concentrations are detected using a PdAg on silicon Schottky diode structure. Sensor temperature control is achieved with a temperature sensor and heater fabricated onto the sensor chip. Results of the characterization of these sensors are presented. These sensors can detect low concentrations of hydrogen in inert environments with high sensitivity and quick response time. Aerojet is developing the hardware and software for a multipoint leak monitoring system designed to provide leak source and magnitude information in real time. The monitoring system processes data from the hydrogen sensors and presents the operator with a visual indication of the leak location and magnitude. Work has commenced on integrating the NASA LeRC-CWRU hydrogen sensors with the Aerojet designed monitoring system. Although the leak monitoring system was designed for hydrogen propulsion systems, the possible applications of this monitoring system are wide ranged. Possible commercialization of the system will also be discussed.

Hunter, Gary W.↗

Real-time space system control with expert systems

Many aspects of space system operations involve continuous control of real time processes. These processes include electrical power system monitoring, prelaunch and ongoing propulsion system health and maintenance, environmental and life support systems, space suit checkout, onboard manufacturing, and vehicle servicing including satellites, shuttles, orbital maneuvering vehicles, orbital transfer vehicles and remote teleoperators. Traditionally, monitoring of these critical real time processes has been done by trained human experts monitoring telemetry data. However, the long duration of future space missions and the high cost of crew time in space creates a powerful economic incentive for the development of highly autonomous knowledge based expert control procedures for these space systems.

Leinweber, David↗

Improved techniques of parallel gap welding and monitoring

Welding programs which show that parallel gas welding is a reliable process are discussed. When monitoring controls and nondestructive tests are incorporated into the process, parallel gap welding becomes more reliable and cost effective. The panel fabrication techniques and the HAC thermal cycling test indicate reliable product integrity. The design and building of automated tooling and fixturing for welding are discussed.

Mardesich, N.↗

In-Situ Real Time Monitoring and Control of Mold Making and Filling Processes: Final Report

This project presents a model for addressing several objectives envisioned by the metal casting industries through the integration of research and educational components. It provides an innovative approach to introduce technologies for real time characterization of sand molds, lost foam patterns and monitoring of the mold filling process. The technology developed will enable better control over the casting process. It is expected to reduce scrap and variance in the casting quality. A strong educational component is integrated into the research plan to utilize increased awareness of the industry professional, the potential benefits of the developed technology, and the potential benefits of cross cutting technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Digital Image Correlation for Performance Monitoring.

Evaluating the health of a mechanism requires more than just a binary evaluation of whether an operation was completed. It requires analyzing more comprehensive, full-field data. Health monitoring is a process of nondestructively identifying characteristics that indicate the fitness of an engineered component. In order to monitor unit health in a production setting, an automated test system must be created to capture the motion of mechanism parts in a real-time and non-intrusive manner. One way to accomplish this is by using high-speed video (HSV) and Digital Image Correlation (DIC). In this approach, individual frames of the video are analyzed to track the motion of mechanism components. The derived performance metrics allow for state-of-health monitoring and improved fidelity of mechanism modeling. The results are in-situ state-of-health identification and performance prediction. This paper introduces basic concepts of this test method, and discusses two main themes: the use of laser marking to add fiducial patterns to mechanism components, and new software developed to track objects with complex shapes, even as they move behind obstructions. Finally, the implementation of these tests into an automated tester is discussed.

47 OTHER INSTRUMENTATION↗

Data acquisition for a real time fault monitoring and diagnosis knowledge-based system for space power system

The design and implementation of the real-time data acquisition and processing system employed in the AMPERES project is described, including effective data structures for efficient storage and flexible manipulation of the data by the knowledge-based system (KBS), the interprocess communication mechanism required between the data acquisition system and the KBS, and the appropriate data acquisition protocols for collecting data from the sensors. Sensor data are categorized as critical or noncritical data on the basis of the inherent frequencies of the signals and the diagnostic requirements reflected in their values. The critical data set contains 30 analog values and 42 digital values and is collected every 10 ms. The noncritical data set contains 240 analog values and is collected every second. The collected critical and noncritical data are stored in separate circular buffers. Buffers are created in shared memory to enable other processes, i.e., the fault monitoring and diagnosis process and the user interface process, to freely access the data sets.

Wilhite, Larry D.↗

Multi-detector system approach for unattended uranium enrichment monitoring at gas centrifuge enrichment plants

Improving the quality of safeguards measurements at Gas Centrifuge Enrichment Plants while reducing the inspection effort is an important objective given the number of existing and new plants that need to be safeguarded. A useful tool in many safeguards approaches is the on-line monitoring of enrichment in process pipes. One requirement of such a monitor is a simple, reliable and precise passive measurement of the 186-keV line from 235 U. The other information required is the amount of gas in the pipe, which can be obtained by a transmission or pressure measurement. Here, we describe our research to develop such a passive measurement system. Unfortunately, a complication arises in the interpretation of the gamma measurements, from the contribution of uranium deposits on the wall of the pipe to the 186-keV peak. A multi-detector approach to address this complication is presented where two measurements, one with signal primarily from gas and one with signal primarily from deposits, are performed simultaneously with different detectors and geometries. This allows a correction to be made to the 186-keV peak for the contribution from the deposit. Finally, we present the design of the multi-detector system and the results of the experimental calibration of the proof-of-principle prototype built at LANL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Statistical porcess control in Deep Space Network operation

This report describes how the Deep Space Mission System (DSMS) Operations Program Office at the Jet Propulsion Laboratory's (EL) uses Statistical Process Control (SPC) to monitor performance and evaluate initiatives for improving processes on the National Aeronautics and Space Administration's (NASA) Deep Space Network (DSN).

Deep Space Network operations statistical process ↗

Development of Processing Technology for Radioactively Contaminated Water at Chernobyl Nuclear Power Plant - 19656

During the operation of the Chernobyl Nuclear Power Plant, distillation by evaporation was the main method for processing radioactively contaminated water. When the plant was decommissioned, the evaporation facility was mothballed and floor drain treatment was suspended in 2016. At present, the existing tanks with the capacity of 26,000 m{sup 3} are more than 60% full with radioactively contaminated floor drains, which requires alternative processing methods. The current process flow for radioactive waste management at State Specialized Enterprise 'Chernobyl NPP' includes processing of accumulated liquid radioactive wastes at a liquid radioactive wastes processing plant. Under the processing technology, liquid radioactive waste is immobilized at the plant by cementation and the resulting solid radioactive waste is then buried in a near-surface storage. Key factors for the selection of alternative radioactively contaminated water processing methods are the possibility to clear the processed water (no control monitoring), which requires the same degree of processing as for drinking water, and minimization of radioactive waste generation due to the lack of free space for solid waste disposal in the near-surface storage. Floor drains that require processing contain radionuclides such as {sup 137}Cs, {sup 90}Sr, {sup 60}Co and {sup 40}K. The current level of the total beta and gamma activity is about 4*105 Bq/kg. The following criteria are set for the Chernobyl NPP site for water to be disposed to the sewerage system: - Max. 37 Bq/kg for the total beta and gamma containing radionuclide activity; - Max. 0.7 Bq/kg for the total alpha containing radionuclide activity. METOIL produces inorganic sorbents for removing radionuclides from liquids and develops sorbent-based technology for a variety of applications related to liquid radioactive waste processing. In 2017-2018, experts from the Chernobyl NPP and METOIL ran several joint laboratory tests to evaluate the efficiency of inorganic sorbents made by METOIL for processing floor drains at the Chernobyl NPP. The test procedure included treatment of radioactively contaminated water in a two-stage sorption process: static sorption (sorbents are mixed in a liquid) and dynamic sorption (the liquid is filtered through a sorbent column). NIKET and MODIKS sorbents were provided for the tests. The results of the test measurements showed that the total alpha containing radionuclide activity is less than 0.026 Bq/kg and the total beta and gamma containing radionuclide activity is 9.2 Bq/kg. The physical and chemical parameters after processing also met the water disposal criteria. High sorption capacity of the sorbents used for the tests allows processing hundreds of water volumes with just one sorbent volume. At present, preparations are underway for full-scale tests at a pilot plant with a capacity of minimum 10 m{sup 3}/day. At a later stage, spent sorbents may be immobilized by inclusion into the cement matrix, which will substantially reduce the amount of radioactive waste to be buried. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Application of LANDSAT to the surveillance and control of lake eutrophication in the Great Lakes Basin

The author has identified the following significant results. Preliminary results in Saginaw Bay show that processed LANDSAT data provides a synoptic view of turbidity and circulation patterns that no degree of ground monitoring can provide. Processed imagery was produced to show nine discrete categories of turbidity, as indicated by nine Secchi depths between 0.3 and 3.3 meters. Analysis of lakes near Madison, Wisconsin show that inland lake water can be categorized by LANDSAT as clear, tannin, algal, and red clay. LANDSAT's capability to inventory watershed land use was throughly demonstrated in the Ohio-Kentucky-Indiana regional planning area. Computer tabulations providing area covered by each of 16 land use categories were rapidly and economically produced for each of the 225 watersheds and nine counties.

Rogers, R. H.↗

Lab-on-a-Fish Monitoring Software V1.0

This is the original monitoring software for processing and displaying data for Lab-on-a-Fish. Lab-on-a-Fish simultaneously evaluates and monitors the health, behavior, and environment of fish or small aquatic species. The sensor is a miniaturized underwater monitoring system that measures animal behavior (acceleration and gyration); physiology (electrocardiogram and electromyogram); and environmental parameters (temperature, pressure, and magnetic sensor).

Deng, Daniel↗

Reverse osmosis water purification system

A reverse osmosis water purification system, which uses a programmable controller (PC) as the control system, was designed and built to maintain the cleanliness and level of water for various systems of a 64-m antenna. The installation operates with other equipment of the antenna at the Goldstone Deep Space Communication Complex. The reverse osmosis system was designed to be fully automatic; with the PC, many complex sequential and timed logic networks were easily implemented and are modified. The PC monitors water levels, pressures, flows, control panel requests, and set points on analog meters; with this information various processes are initiated, monitored, modified, halted, or eliminated as required by the equipment being supplied pure water.

Ahlstrom, H. G.↗

Intelligent robotic tracker

An intelligent tracker capable of robotic applications requiring guidance and control of platforms, robotic arms, and end effectors has been developed. This packaged system capable of supervised autonomous robotic functions is partitioned into a multiple processor/parallel processing configuration. The system currently interfaces to cameras but has the capability to also use three-dimensional inputs from scanning laser rangers. The inputs are fed into an image processing and tracking section where the camera inputs are conditioned for the multiple tracker algorithms. An executive section monitors the image processing and tracker outputs and performs all the control and decision processes. The present architecture of the system is presented with discussion of its evolutionary growth for space applications. An autonomous rendezvous demonstration of this system was performed last year. More realistic demonstrations in planning are discussed.

Otaguro, W. S.↗

Digital Image Correlation for Performance Monitoring

Evaluating the health of a mechanism requires more than just a binary evaluation of whether an operation was completed. It requires analyzing more comprehensive, full-field data. Health monitoring is a process of non-destructively identifying characteristics that indicate the fitness of an engineered component. In order to monitor unit health in a production setting, an automated test system must be created to capture the motion of mechanism parts in a real-time and non-intrusive manner. One way to accomplish this is by using high-speed video and Digital Image Correlation (DIC). In this approach, individual frames of the video are analyzed to track the motion of mechanism components. The derived performance metrics allow for state-of-health monitoring and improved fidelity of mechanism modeling. The results are in-situ state-of-health identification and performance prediction. This paper introduces basic concepts of this test method, and discusses two main themes: the use of laser marking to add fiducial patterns to mechanism components, and new software developed to track objects with complex shapes, even as they move behind obstructions. Finally, the implementation of these tests into an automated tester is discussed.

Palaviccini, Miguel↗