Kinetic Simulations of Radiative Magnetic Reconnection in the Coronae of Accreting Black Holes

We perform 2D and 3D particle-in-cell simulations of reconnection in magnetically dominated e ± plasmas subject to strong Compton cooling. Magnetic reconnection under such conditions can operate in accretion disk coronae around black holes, which produce hard X-rays through Comptonization. Our simulations show that most of the plasma in the reconnection layer is kept cold by Compton losses and locked in magnetically dominated plasmoids with a small thermal pressure. Compton drag clears cavities inside plasmoids and also affects their bulk motions. These effects, however, weakly change the reconnection rate and the plasmoid size distribution from those in nonradiative reconnection. This demonstrates that the reconnection dynamics is governed by similar magnetic stresses in both cases and weakly affected by thermal pressure. We examine the energy distribution of particles energized by radiative reconnection and observe two distinct components: (1) A mildly relativistic peak, which results from bulk motions of cooled plasmoids. This component receives most of the dissipated reconnection power and dominates the output X-ray emission. The peak has a quasi-Maxwellian shape with an effective temperature of ~100 keV. Thus, it mimics thermal Comptonization used previously to fit hard-state spectra of accreting black holes. (2) A high-energy tail, which receives ~20% of the dissipated reconnection power. It is populated by particles accelerated impulsively at X-points or "picked up" by fast outflows from X-points. The high-energy particles immediately cool, and their inverse Compton emission explains the MeV spectral tail detected in the hard state of Cyg X-1. Our first-principle simulations support magnetic reconnection as a mechanism powering hard X-ray emission from magnetically dominated regions of accreting black holes.

79 ASTRONOMY AND ASTROPHYSICS↗

Microstructure effects on high velocity microparticle impacts of copper

Constitutive models can fail to predict high-rate deformation behavior due to their inability to account for microstructural effects. In part, this is because of a dearth of experimental benchmarking data in the high strain-rate, low pressure regime, since many high-rate experiments also probe a region of strong shockwaves, at which point microstructure effects no longer play a primary role. This work uses laser-induced particle impact testing to quantitatively study high velocity impacts of small, rigid alumina microspheres on flat copper substrates with varying amounts of initial cold work in the weak shock regime, but at very high strain rates up to ~10 7 s –1 . Through paired experiments and numerical simulations, this work shows that the initial microstructure condition can have significant influence on dynamical mechanical properties in this range. Specifically, prior work hardening of the copper substrate leads to increased rebounding of the microparticles (i.e., less plastic dissipation in the impact) as well as smaller craters. Each of these experimental measurables can be converted into a strength measure, i.e., the dynamic yield strength or dynamic hardness, respectively, neither of which is well predicted consistently by existing constitutive laws. The general trend of hardening can be captured by such models by incorporating an existing “pre-strain,” suggesting that future calibration of the materials parameters may yield a good fit over a broader range of conditions. Our results emphasize the importance of reporting the microstructural condition in dynamic studies, as well as the necessity of accounting for these factors when formulating and optimizing constitutive models.

36 MATERIALS SCIENCE↗

Analysis of real-fluid thermodynamic effects on turbulent statistics in transcritical channel flows

Wall-bounded turbulence at high-pressure transcritical conditions with intense density fluctuations are encountered in many technical applications. In this study, we analyze the turbulent energy transport in transcritical channel flows specifically focusing on dissipation rate, turbulent kinetic energy budgets, heat fluxes, and momentum-fluctuation statistics; results from this analysis are used to guide the development of turbulent scaling laws. Furthermore, we find that the dissipation rate of turbulent kinetic energy is dominated by the enstrophy in the logarithmic layer, and the fluctuating viscosity results in the reduced tilting of the vortical structures and the attenuation of streamwise vorticity in the near-wall layer; the fluctuating viscosity attenuates the dissipation rate by reducing the shear strain and the enstrophy production. Local equilibrium of the turbulent kinetic energy exists in the logarithmic layer. We show that the real-fluid thermodynamic effects significantly change the turbulent heat flux correlated with the sweep and the ejection events; the density changes alter the turbulent transport and result in noticeable magnitudes of density-fluctuation-related momentum-fluctuation statistics. From these results, scaling laws for the turbulent length scales and turbulent kinetic energy budgets are proposed, thereby contributing to improvement of the wall models in large-eddy simulations and Reynolds-averaged Navier-Stokes (RANS) simulations.

42 ENGINEERING↗

Virtual Design and Analysis of the Balancing Element of an External Gear Machine Considering Cavitation and Mixed Lubrication Effects

This report presents a simulation based approach for sizing the axial balance elements of a pressure compensated external gear machine. The reference hydraulic unit must be able to guarantee operation in two quadrants, as either a pump or a motor. It also needs to operate in a wide operating range of speed and pressure, as it is to be used as primary hydraulic unit for an electro-hydraulic actuator (EHA). The design procedure builds upon past work at the author’s center, but it extends it to the case of multiple quadrant units. Also, a unique method for modeling of both mixed lubrication and cavitation that might occur in the lubricating film is used. After describing the design procedure, the paper discusses the features of the balancing of a reference unit, along with the effects of both cavitation and mixed lubrication.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Factors controlling injection-induced rupture of intersecting faults during geological sequestration of CO 2

This study addresses coupled multiphase fluid flow and geomechanics effects on potential fault activation associated with subsurface CO 2 injection around intersecting faults. An enhanced fault-representation model is used to capture geomechanical responses of two intersecting faults with finite length during CO 2 injection. The faults are embedded in a strike-slip stress regime of a caprock-reservoir-basement system with the faults represented by zero-thickness interfaces with adjacent finite-thickness damage zones. A sensitivity analysis is conducted to study the effect of fault permeability, slip-weakening behavior, well location relative to the orientation of faults, and well placement (the number and location of injection wells). Five metrics (pressure, CO 2 plume, shear state on the fault, as well as shear displacement and stress path at selected fault monitoring points) are selected to assess CO 2 migration and reactivation of intersecting faults. The results show that induced ruptures are favored by low permeability faults due to high pressure buildup and by slip-weakening behavior resulting from fault strength reduction. The location of one injection well relative to fault orientation determines the magnitude of changes in effective normal stress and shear stress, affecting the location of induced ruptures. Well placement (two injection wells used in the paper) dominates pressure diffusion around the intersection and tips of faults. This redistributes changes in effective normal stress caused by each injection well, influencing the spatial distribution of ruptures along faults. A larger injection volume induces far-field ruptures that are controlled by stress transfer within the injection layer. The findings presented here can provide valuable insights into engineering operations for a long-term, safe, and reliable geologic CO 2 storage.

Fault permeability↗

Computational Analysis of the Effect of Structured Packing Design on Absorption Column Hydrodynamics for Post-Combustion Carbon Capture Applications

Solvent based post-combustion carbon capture technologies have a potential for reducing carbon emissions from fossil-fuel-fired power plants and industrial sources where CO2 emissions are inherently harder to mitigate, such as steel or cement industries. A prominent technology to achieve this is by retrofitting absorption columns to the existing infrastructure. While these systems have been among the less costly alternatives for carbon capture, they still impose a considerable energy penalty to the operation of power plants or industrial facilities. The optimization of CO2 capture rate in solvent-based absorption process is complex as it depends on several factors including CO2 solubility, solvent reaction kinetics and temperature effects on the solubility, reaction rates, surface tension, and thermophysical properties of the solvent and the flue gas. The overall heat and mass transfer also depends on the hydrodynamics, which in turn, is affected by the packing geometry. In the current work, we systematically quantify the effects the design of the structured packing has on the column hydrodynamics, by performing detailed CFD simulations for different geometrical configurations and operating conditions. We then obtain relationships between the key hydrodynamic metrics, such as liquid holdup, interfacial area, wetted area, and pressure drop to the parameters defining the packing geometries and identify new more effective packing designs for the given operating conditions.

Shah, Yash Girish↗

A numerical investigation of coal particle modeling for the inlet section of a pressurized oxy-combustion burner

Concerns over climate change have led to numerous efforts to develop low-carbon technologies, and pressurized oxy-combustion (POC) is a promising candidate to reduce carbon emissions in the power industry. Designing an effective burner for such technologies is vital for the development of these and other coal combustion technologies. Because of the high pressure, the volume fraction of coal particles at the fuel inlet of the pressurized oxy-combustor burner is close to or even higher than the maximum limit for commercial CFD codes (e.g., ANSYS FLUENT). At these high particle volume fractions, the interactions among particles, fluid flow and wall need to be re-evaluated. The present computational work is a first step in a systematic analysis of the influence of various parameters, like method of particle release, release location, and particle size, in a pilot-scale POC combustor, developed at Washington University in St. Louis (WUSTL). In the POC process, pulverized coal is burned under elevated pressure in an O2-CO2 environment. Specifically, a 15-bar, 100 kWth, POC combustor is modeled employing Ansys FLUENT commercial sodtware using the Reynolds-Averaged Navier-Stokes (RANS) approach. It is revealed that for this pilot-scale, pressurized burner, velocity profiles in the near-wall region exhibit some anomalies. In order to investigate the influence of particle loading in the near-wall region, particle release location was investigated. The numerical simulations incorporate the coupling between the turbulent flow and the particles. A sensitivity investigation of particle release location found that by tuning the release location, the velocity profile can be consistent with the pure gas flow velocity profile. More importantly, the particle releasing location also affects flame stability. Particle size was also found to have a significant impact on particle trajectory, flame stability and temperature. Finally, Large Eddy Simulations (LES) were performed and compared with the results from two-dimensional RANS.

Li, Lei↗

A Boosted Critical Temperature of 166 K in Superconducting D 3 S Synthesized from Elemental Sulfur and Hydrogen

The discovery of superconductivity in H 3 S at 203 K marked an advance towards room-temperature superconductivity and demonstrated the potential of H-dominated compounds to possess a high critical temperature (T c ). There have been numerous reports of the H-S system over the last five years, but important questions remain unanswered. It is crucial to verify whether the Tc was determined correctly for samples prepared from compressed H 2 S, since they are inevitably contaminated with H-depleted byproducts. Here, we prepare stoichiometric H 3 S by direct in situ synthesis from elemental S and excess H 2 . The Im$_\bar{3}$ m phase of D 3 S samples exhibits a T c significantly higher than previously reported values (ca. 150 K), reaching a maximum T c of 166 K at 157 GPa. Furthermore, we confirm that the sharp decrease in T c below 150 GPa is accompanied by continuous rhombohedral structural distortions and demonstrate that the Cccm phase is nonmetallic, with molecular H 2 units in the crystal structure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Parabolic oxidation kinetics of a plutonium alloy at room temperature

Auger electron spectroscopy (AES) was used to characterize the oxide scale formed on an ~0.5 wt. % Ga plutonium metal alloy. Analysis of changes to the characteristic Auger transitions for Pu and O during sputter depth profiles were used in combination with previously measured sputter yields to determine the thickness of the oxide scale and provide insight into its chemistry. From this data, the parabolic kinetics for the Pu-Ga alloy were determined as a function of relative humidity, RH = 14–92%, and oxygen partial pressure, p(O 2 ) = 31–157 Torr, at 25°C. For each relative humidity investigated, the parabolic rate constant was found to be independent of oxygen partial pressure. Furthermore, power-law fits to the relative humidity effect on the rate constant was found to have a power of n = 1.265, indicating the diffusion species which rate-limits the reaction isn’t molecular water, which subsequent dissociates at the oxide-metal interface, or hydroxyl from dissociation at the gas-surface interface.

36 MATERIALS SCIENCE↗

Experimental test of model predictive control in a variable air volume system

Model predictive control (MPC) has been widely studied as a promising approach for improving energy efficiency and operational flexibility in buildings, yet its real-world performance for commercial variable air volume (VAV) systems remains insufficiently characterized. In particular, the impacts of model mismatch on control robustness, real-time computational burden, and device-level operation are rarely evaluated using long-term field data. Here, this study presents a comprehensive experimental evaluation of MPC applied to a full-scale VAV system in Oak Ridge National Laboratory’s Flexible Research Platform-2 building with constant cooling/heating temperature setpoints and no occupancy. The study offers three key advantages over existing work: (1) it uses a representative building in a full-scale experimental test, capturing realistic system dynamics and complexity; (2) it evaluates a relatively sophisticated MPC formulation using two different optimization solvers (Gurobi and PSO), fully accounting for computational complexity and methodological diversity; and (3) it systematically assesses potential negative impacts on various building devices, benchmark against a well-established baseline, ASHRAE Guideline 36 (G36). To isolate zone- and air-handling-unit–level supervisory control effects, the supply fan was operated with a fixed static pressure setpoint under all strategies, and the trim-and-response static pressure reset in G36 was not enabled. Results show that MPC maintained thermal comfort while improving energy efficiency. Abrupt solar radiation variations degraded performance. Computation times ranged from ∼1 s (Gurobi) to ∼ 70 s (PSO). Compared with G36, MPC achieves 33% energy savings and reduces median reheat coil output by approximately a factor of 5–10 for a representative cooling day under matched weather conditions. However, it increases the maximum discomfort deviation from 0.5 to 1°C and results in a 32% increase in staging frequency. In addition, PSO-based MPC introduced damper oscillations, also affecting actuator longevity.

ASHRAE guideline 36↗

One-dimensional, transient modeling of a fixed-bed regenerator as a replacement for recuperators in supercritical CO 2 power cycles

Fixed-bed regenerators may be a low cost alternative to recuperators for supercritical CO 2 power cycles. However, the transient nature of regenerators operating in sCO 2 power cycles has not been previously characterized. This study details a one-dimensional, transient model of a fixed-bed regenerator that captures phenomena such as local fluid properties and heat transfer coefficients, entrained fluid heat capacity, and the effects of conservation of mass during process switching. The model is validated with experimental results of a 10 kWth regenerator. This comparison shows that the model predicts temperature as a function of both time and space exceptionally well. The model predicts effectiveness, heat transfer, and discharge temperatures within 5%, and predicts pressure drop and fluid carryover within 10%. This model could be used in future studies to simulate regenerators within a supercritical CO 2 power cycle.

30 DIRECT ENERGY CONVERSION↗

Effective thermal conductivity of insulation materials for cryogenic LH 2 storage tanks: A review

An accurate estimation of the effective thermal conductivity of various insulation materials is essential in the evaluation of heat leak and boil-off rate from liquid hydrogen storage tanks. In this work, we review the existing experimental data and various proposed correlations for predicting the effective conductivity of insulation systems consisting of powders, foams, fibrous materials, and multilayer systems. We also propose a first principles-based correlation that may be used to estimate the dependence of the effective conductivity as a function of temperature, interstitial gas composition, pressure, and structural properties of the material. We validate the proposed correlation using available experimental data for some common insulation materials. Further improvements and testing of the proposed correlation using laboratory scale data obtained using potential LH 2 tank insulation materials are also discussed.

08 HYDROGEN↗

Hydrogen and deuterium permeation in Hastelloy N

Hastelloy N was chosen as the fluoride salt-contacting structural material for the Molten Salt Reactor Experiment due to its excellent compatibility with the fuel salt FLiBe. FLiBe is currently investigated for several advanced fusion and fission reactor concepts where tritium generation in the FLiBe is anticipated. Knowledge of hydrogen transport properties through Hastelloy N is important to understand how tritium would permeate through this material and result in an unintentional release. In this study, the hydrogen and deuterium permeability, diffusivity, and solubility were measured from 500 to 700 °C at a primary-side pressure of 10 kPa in a well-characterized sample of Hastelloy N. The prepared polycrystalline Hastelloy N had C and O impurities present on the surface. These impurities were investigated using Auger Emission Spectroscopy and Ar depth profiling. Here, the adventitious C was removed upon the first Ar sputter cycle whereas O persisted deeper into the sample. For permeation experiments, applied deuterium pressures ranged from 13 Pa to 100 kPa and deuterium transport remained in the diffusion-limited regime (J ∝ P 0.5 ) throughout the pressure range examined. Two methods are employed to measure the effective hydrogen and deuterium diffusivity: rise and decline. The decline method produced improved statistical model fits for calculating the effective diffusion coefficient compared to the rise method. The resultant transport properties compared well to published values for other nickel alloys.

08 HYDROGEN↗

Versatile coating with multifunctional performance for solar steam generation

In this work, a new kind of material, composite complex coating (CCC), with multifunctional performance has been developed for solar steam generation. The CCC has many advantages: (a) Scalability. The fabrication process is facile and mild; it can be realized in aqueous solution at room temperature, without high pressure, toxic organic solvents, or complex equipment. (b) Cost-effectiveness. The reagents used for preparation of CCC are low-cost and readily available. (c) Universality and stability. CCC firmly adheres on surfaces of various substrates with diverse shapes (cotton, filter paper, wood, polyurethane sponge, and even chemically inert and highly hydrophobic polyvinylidene fluoride membranes), and can withstand rinsing treatment (3000 r/min for 96 h), cyclic frost-thaw test (-18 °C ⇌ 30 °C, 90 times), and both high and low pH environments. In addition, many other reported coatings, such as carbon black, fail under similar process strain. (d) Anti-crude oil-fouling property. The CCC possesses stable superhydrophilicity and underwater superoleophobicity, which collectively endow substrates with the ability to resist fouling by oils. (e) Broad and strong light absorption. CCC can transform various substrates with diverse shapes into black materials with broadband light absorption due to its d-d transitions and rough surface. Together, these properties of CCC enable substrates with nearly any structural design to be easily transformed into photothermal materials for efficient solar steam generation. Furthermore, as a proof of concept, poplar wood is treated with CCC, achieving a water evaporation rate of ~1.8 kg m-2 h-1 (one sun), which is a record among wood-based photothermal materials.

14 SOLAR ENERGY↗

Flow reversal benchmark of a one-sided heated narrow rectangular channel with CATHARE and RELAP5

Flow reversal in narrow coolant channels can be a crucial phenomenon for the safety of research reactors with a downward nominal flow direction. During a loss of forced flow accident, the downward flow stagnates briefly before transitioning into an upward natural circulation flow. The fuel may be damaged if dryout occurs and threshold fuel and/or cladding temperatures are exceeded. A comprehensive study is provided for flow reversal in narrow rectangular channels by examining experimental data and conducting software model analyses. The literature on flow reversal was reviewed, and selected experimental datasets were used to benchmark against CATHARE and RELAP5 models and also compare the code calculations with each other. The experimental data comes from flow reversal tests conducted with a narrow rectangular channel with one-sided heating. The results were compared with experimental data for successful flow reversal tests and predicted dryout power for dryout conditions. Also, the study examined the effects of the pump coastdown period, inlet liquid temperature, system pressure, and localized pressure drops. The experimental results showed that shorter coastdown periods, reduced pressure drops, and lower coolant inlet temperatures increased the dryout power. However, the system pressure did not noticeably affect the results. The simulation results showed that both CATHARE and RELAP5 agreed with experimental data, capturing the trends of the experimental results. Slight differences between each code calculation, as well as the predicted and measured dryout powers, were attributed to experimental uncertainties and the modeling of physical phenomena such as wall nucleation, interfacial heat transfer, drag coefficients, and critical heat flux. Overall, this study provides an understanding of flow reversal and the prediction capabilities of thermal-hydraulics software models. In conclusion, a future study of the flow reversal benchmark of a narrow rectangular channel with two-sided heating may provide additional valuable insights.

CATHARE↗

Advancing the physics basis for quasi-helically symmetric stellarators

A new optimized quasi-helically symmetric configuration is described that has the desirable properties of improved energetic particle confinement, reduced turbulent transport by three-dimensional shaping and non-resonant divertor capabilities. The configuration presented in this paper is explicitly optimized for quasi-helical symmetry, energetic particle confinement, neoclassical confinement and stability near the axis. Post optimization, the configuration was evaluated for its performance with regard to energetic particle transport, ideal magnetohydrodynamic stability at various values of plasma pressure and ion temperature gradient instability induced turbulent transport. The effects of discrete coils on various confinement figures of merit, including energetic particle confinement, are determined by generating single-filament coils for the configuration. Preliminary divertor analysis shows that coils can be created that do not interfere with expansion of the vessel volume near the regions of outgoing heat flux, thus demonstrating the possibility of operating a non-resonant divertor.

Physics↗

Structure of an Atmospheric River over Australia and the Southern Ocean. Part I: Tropical and Midlatitude Water Vapor Fluxes

An atmospheric river (AR) impacting Australia-Tasmania and the Southern Ocean during the Austral summer on 28-29 January 2018 during the SOCRATES campaign is analyzed using both a modeling and observational approach. Gulfstream-V dropsonde measurements and GPM radar analyses were used in conjunction with Weather Research and Forecasting model simulations with water vapor tracers to investigate the relative contributions of tropical and mid-latitude moisture sources to the AR. Moisture associated with a monsoonal tropical depression became entrained into a mid-latitude frontal system that extended to 60°S over the Southern Ocean reaching the associated low pressure system 850 km off the east coast of Antarctica – effectively connecting the tropics and the polar region. Tropical moisture contributed to about 50% of the precipitable water within the AR. The tropical contribution to precipitation decreased with latitude, from > 70% over the Australian continent, to ~50% off the Australian coast, to less than 10% poleward of 60°S. Precipitation in the AR conformed to a seeder-feeder model, the seeder precipitation forming primarily from tropical sourced moisture above the altitude of the 0°C isotherm, and the feeder precipitation sourced from mid-latitude sourced moisture below the altitude of the 0°C isotherm. The integrated vapor transport (IVT) through the core of the AR reached above 500 kg m-1s-1 during 1200 UTC 28 January to 0600 UTC 29 January 29, 1.29 times the average amount of water carried by the world’s largest river, the Amazon. The high IVT strength might be attributed to the higher water vapor content associated with the warmer temperatures in Austral summer.

Rauber, Robert M.↗

A negative piezo-conductive effect from doped semiconducting polymer thin films

In the past years, piezo-conductive sensors have drawn great attention in both academic and industrial sectors. The piezo-conductive sensors made by inorganic semiconductors exhibited poor mechanical flexibility, restricting their further practical applications. In this study, we report the piezo-conductive sensors by a semiconducting polymer, poly(3,4-ethylenedioxythiophene) doped with tosylate ions (PEDOT:Tos) thin films. Systemically studies indicate that the piezo-conductive response of the PEDOT:Tos thin films is originated from the deformation of the PEDOT crystal cells and the stretched π–π distances induced by Tos. Moreover, the negative piezo-conductive effect, for the first time, is observed from PEDOT:Tos thin film under the pressure. A working mechanism is further proposed to interpret the transient from a positive to a negative piezo-conductive response within the PEDOT:Tos thin films. Our studies offer a facile route to approach effective piezo-conductive sensors based on conjugated polymers.

36 MATERIALS SCIENCE↗